Refine
Is part of the Bibliography
- yes (15)
Document Type
- Journal article (13)
- Doctoral Thesis (2)
Language
- English (15) (remove)
Keywords
- echocardiography (15) (remove)
Institute
- Medizinische Klinik und Poliklinik I (10)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (9)
- Medizinische Klinik und Poliklinik II (3)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (2)
- Medizinische Fakultät (2)
- Neurologische Klinik und Poliklinik (2)
- Institut für Klinische Epidemiologie und Biometrie (1)
- Institut für Mathematik (1)
- Missionsärztliche Klinik (1)
- Pathologisches Institut (1)
Sonstige beteiligte Institutionen
Introduction: Speckle-tracking echocardiography has recently emerged as a quantitative ultrasound technique for accurately evaluating myocardial function by analyzing the motion of speckles identified. Speckle-tracking obtained under stress may offer an opportunity to improve the detection of dynamic regional abnormalities and myocardial viability.
Objective: To evaluate stress speckle tracking as tool to detect myocardial viability in comparison to cardiac MRI in post-STEMI patients.
Methods: 49 patients were prospectively enrolled in our 18-month’s study. Dobutamin stress echocardiography was performed 4 days post-infarction accompanied with automated functional imaging (Speckle tracking) analysis of left ventricle during rest and then during low dose stress. All patients underwent a follow up stress echocardiography at 6 weeks with speckle tracking analysis. Cardiac MRI took place concomitantly at 4 days post-infarction and 6 weeks. We carried out an assessment of re-admission with acute coronary syndrome (ACS) after one year of enrollment.
Results: Investigating strain rate obtained with stress speckle tracking after revascularization predicted the extent of myocardial scar, determined by contrast-enhanced magnetic resonance imaging. A good correlation was found between the global strain and total infarct size (R 0.75, p< 0.001). Furthermore, a clear inverse relationship was found between the segmental strain and the transmural extent of infarction in each segment. (R -0.69, p<0.01). Meanwhile it provided 81.82% sensitivity and 82.6% specificity to detect transmural from non-transmural infarction at a cut-off value of -10.15. Global stress strain rate showed 80% sensitivity and 77.5% specificity at a cut-off value of -9.1 to predict hospital re-admission with ACS. A cut-off value of -8.4 had shown a 69.23% sensitivity and 73.5% specificity to predict the re-admission related to other cardiac symptoms.
Conclusion: Strain rate obtained from speckle tracking during stress is a novel method of detecting myocardial viability after STEMI .Moreover it carries a promising role in post-myocardial infarction risk stratification with a reasonable prediction of reversible cardiac-related hospital re-admission.
Introduction: Speckle-tracking echocardiography has recently emerged as a quantitative ultrasound technique for accurately evaluating myocardial function by analyzing the motion of speckles identified. Speckle-tracking obtained under stress may offer an opportunity to improve the detection of dynamic regional abnormalities and myocardial viability.
Objective: To evaluate stress speckle tracking as tool to detect myocardial viability in comparison to cardiac MRI in post-STEMI patients.
Methods: 49 patients were prospectively enrolled in our 18-month’s study. Dobutamin stress echocardiography was performed 4 days post-infarction accompanied with automated functional imaging (Speckle tracking) analysis of left ventricle during rest and then during low dose stress. All patients underwent a follow up stress echocardiography at 6 weeks with speckle tracking analysis. Cardiac MRI took place concomitantly at 4 days post-infarction and 6 weeks. We carried out an assessment of re-admission with acute coronary syndrome (ACS) after one year of enrollment.
Results: Investigating strain rate obtained with stress speckle tracking after revascularization predicted the extent of myocardial scar, determined by contrast-enhanced magnetic resonance imaging. A good correlation was found between the global strain and total infarct size (R 0.75, p< 0.001). Furthermore, a clear inverse relationship was found between the segmental strain and the transmural extent of infarction in each segment. (R -0.69, p<0.01). Meanwhile it provided 81.82% sensitivity and 82.6% specificity to detect transmural from non-transmural infarction at a cut-off value of -10.15. Global stress strain rate showed 80% sensitivity and 77.5% specificity at a cut-off value of -9.1 to predict hospital re-admission with ACS. A cut-off value of -8.4 had shown a 69.23% sensitivity and 73.5% specificity to predict the re-admission related to other cardiac symptoms.
Conclusion: Strain rate obtained from speckle tracking during stress is a novel method of detecting myocardial viability after STEMI .Moreover it carries a promising role in post-myocardial infarction risk stratification with a reasonable prediction of reversible cardiac-related hospital re-admission.
This expert opinion paper on cardiac imaging after acute ischemic stroke or transient ischemic attack (TIA) includes a statement of the "Heart and Brain" consortium of the German Cardiac Society and the German Stroke Society. The Stroke Unit-Commission of the German Stroke Society and the German Atrial Fibrillation NETwork (AFNET) endorsed this paper. Cardiac imaging is a key component of etiological work-up after stroke. Enhanced echocardiographic tools, constantly improving cardiac computer tomography (CT) as well as cardiac magnetic resonance imaging (MRI) offer comprehensive non- or less-invasive cardiac evaluation at the expense of increased costs and/or radiation exposure. Certain imaging findings usually lead to a change in medical secondary stroke prevention or may influence medical treatment. However, there is no proof from a randomized controlled trial (RCT) that the choice of the imaging method influences the prognosis of stroke patients. Summarizing present knowledge, the German Heart and Brain consortium proposes an interdisciplinary, staged standard diagnostic scheme for the detection of risk factors of cardio-embolic stroke. This expert opinion paper aims to give practical advice to physicians who are involved in stroke care. In line with the nature of an expert opinion paper, labeling of classes of recommendations is not provided, since many statements are based on expert opinion, reported case series, and clinical experience.
Background:
Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI.
Methods:
We analysed 124 patients who underwent successful TAVI using a self-expandable prosthesis, divided equally into two groups; in the study group we used the cross sectional short axis 2D-TEE for measurement of the aortic annulus and in the control group we used the long axis 2D-TEE.
Results:
Both groups were comparable regarding the clinical parameters. On the other hand, patients in the study group had less left ventricular ejection fraction (38.9 % versus 45.6 %, p = 0.01). The aortic valve annulus was, although not statistically significant, smaller in the study group (21.58 versus 23.28 mm, p = 0.25). Post procedural quantification of the aortic regurgitation revealed that only one patient in both groups had severe aortic regurgitation (AR), in this patient the valve was implanted deep. The incidence of significant AR was higher in the control group (29.0 % versus 12.9 %, p = 0.027).
Conclusions:
Sizing of the aortic valve annulus using cross-sectional 2D-TEE offers a safe and plausible method for patients undergoing TAVI using the self-expandable prosthesis and is significantly superior to using long axis 2D-TEE.
Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus.
Methods: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. Results: Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 +/- 4 years, and 25 patients (55.6 %) were female. Mean aortic annulus diameter was 20.3 +/- 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 +/- 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over-or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 % of patients.
Conclusions: CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies.