(1) Background: Interventional endoscopic procedures are growing more popular, requiring innovative instruments and novel techniques. Three-dimensional printing has demonstrated great potential for the rapid development of prototypes that can be used for the early assessment of various concepts. In this work, we present the development of a flexible endoscopic instrument and explore its potential benefits. (2) Methods: The properties of the instrument, such as its maneuverability, flexibility, and bending force, were evaluated in a series of bench tests. Additionally, the effectiveness of the instrument was evaluated in an ex vivo porcine model by medical experts, who graded its properties and performance. Furthermore, the time necessary to complete various interventional endoscopic tasks was recorded. (3) Results: The instrument achieved bending angles of ±216° while achieving a bending force of 7.85 (±0.53) Newtons. The time needed to reach the operating region was 120 s median, while it took 70 s median to insert an object in a cavity. Furthermore, it took 220 s median to insert the instrument and remove an object from the cavity. (4) Conclusions: This study presents the development of a flexible endoscopic instrument using three-dimensional printing technology and its evaluation. The instrument demonstrated high bending angles and forces, and superior properties compared to the current state of the art. Furthermore, it was able to complete various interventional endoscopic tasks in minimal time, thus potentially leading to the improved safety and effectiveness of interventional endoscopic procedures in the future.
Purpose
Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time–activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative \(^{177}\)Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise.
Methods
The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities.
Results
Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla.
Conclusion
This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
A method is reported for making hollow channels within hydrogels decorated with cell‐adhesion peptides exclusively at the channel surface. Sacrificial fibers of different diameters are used to introduce channels within poly(ethylene glycol) hydrogels crosslinked with maleimide‐thiol chemistry, which are backfilled with a cysteine‐containing peptide solution which is conjugated to the lumen with good spatial efficiency. This allows for peptide patterning in only the areas of the hydrogel where they are needed when used as cell‐guides, reducing the amount of required peptide 20‐fold when compared to bulk functionalization. The power of this approach is highlighted by successfully using these patterned hydrogels without active perfusion to guide fibroblasts and olfactory ensheathing cells—the latter having unique potential in neural repair therapies.