Refine
Has Fulltext
- yes (3)
Is part of the Bibliography
- yes (3)
Document Type
- Doctoral Thesis (2)
- Journal article (1)
Keywords
- modular (3) (remove)
Institute
- Lehrstuhl für Orthopädie (3) (remove)
Background: We present a descriptive and retrospective analysis of revision total hip arthroplasties (THA) using the MRP-TITAN stem (Peter Brehm, Weisendorf, GER) with distal diaphyseal fixation and metaphyseal defect augmentation. Our hypothesis was that the metaphyseal defect augmentation (Impaction Bone Grafting) improves the stem survival.
Methods: We retrospectively analyzed the aggregated and anonymized data of 243 femoral stem revisions. 68 patients with 70 implants (28.8%) received an allograft augmentation for metaphyseal defects; 165 patients with 173 implants (71.2%) did not, and served as controls. The mean follow-up was 4.4 +/- 1.8 years (range, 2.1-9.6 years). There were no significant differences (p > 0.05) between the study and control group regarding age, body mass index (BMI), femoral defects (types I-III as described by Paprosky), and preoperative Harris Hip Score (HHS). Postoperative clinical function was evaluated using the HHS. Postoperative radiologic examination evaluated implant stability, axial implant migration, signs of implant loosening, periprosthetic radiolucencies, as well as bone regeneration and resorption.
Results: There were comparable rates of intraoperative and postoperative complications in the study and control groups (p > 0.05). Clinical function, expressed as the increase in the postoperative HHS over the preoperative score, showed significantly greater improvement in the group with Impaction Bone Grafting (35.6 +/- 14.3 vs. 30.8 +/- 15.8; p <= 0.05). The study group showed better outcome especially for larger defects (types II C and III as described by Paprosky) and stem diameters >= 17 mm. The two groups did not show significant differences in the rate of aseptic loosening (1.4% vs. 2.9%) and the rate of revisions (8.6% vs. 11%). The Kaplan-Meier survival for the MRP-TITAN stem in both groups together was 93.8% after 8.8 years. [Study group 95.7% after 8.54 years; control group 93.1% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3% vs. 9.3%; p = 0.19) but a significant reduction in proximal stress shielding (5.7% vs. 17.9%; p < 0.05) in the study group. Periprosthetic radiolucencies were detected in 5.7% of the study group and in 9.8% of the control group (p = 0.30). Radiolucencies in the proximal zones 1 and 7 according to Gruen occurred significantly more often in the control group without allograft augmentation (p = 0.05).
Conclusion: We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III) and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted.
Klinisch-radiologische Evaluation des Merete® BioBall™-Adapter-Systems in der Hüftendoprothetik
(2021)
Die Revisionsendoprothetik des Hüftgelenkes ist eine große Herausforderung, insbesondere bei Teilwechseln von Komponenten bei fest-implantiertem Schaft. In einer retrospektiven Analyse wurde eine Implantat-Komponente des Medizinprodukteherstellers Merete Medical (Berlin) untersucht. Ziel der Untersuchung war es, eine Aussage über die Stabilität des Implantats und den klinischen Versorgungserfolg bei dessen Verwendung treffen zu können. Es wurden Daten von insgesamt 72 Patienten erhoben. Es erfolgte eine klinische und radiologische Nachuntersuchung. Die Daten wurden einer deskriptiven und explorativen Analyse unterzogen, eine Überlebenszeitanalyse wurde durchgeführt. Das Implantat zeigte mechanische Stabilität in einem mittelfristigen Zeitraum. Der Versorgungserfolg (gemessen am Harris Hip Score) war durchschnittlich bis gut. Es zeigten sich Zusammenhänge zwischen dem präoperativen Zustand der Patienten und dem Versorgungerfolg.
Im Zeitraum zwischen Januar 1998 bis März 2000 wurden 51 Patienten, die mit einer MRP- Hüft-Revisionsprothese versorgt worden sind klinisch und radiologisch nachuntersucht. Das mittlere follow-up betrug 2,1 Jahre (1,1-3,8 Jahre).Das Durchschnittsalter der Patienten betrug 69,4 Jahre. Der mittlere HHS verbesserte sich von 37,8 % prä-operativ auf 77,3 % post-operativ. 64% der mit der MRP-Prothese versorgten Patienten waren zum Zeitpunkt der letzten Kontrolle völlig schmerzfrei. 84.3% der Patienten waren mit dem Revisionseingriff sehr zufrieden. Es zeigte sich, dass dieses Prothesensystem selbst bei Patienten mit schwerwiegenden Defekten im Bereich des proximalen Femur ein gutes Behandlungskonzept darstellt. Es konnte nach dem Revisionseingriff kein signifikanter Unterschied im HHS im Vergleich der Gruppen mit unterschiedlichen Knochendefekten am Femur festgestellt werden. Mechanische Komplikationen die auf den modularen Aufbau der Prothese zurückzuführen wären, waren nicht nachweisbar