This work deals with the acceleration of cardiovascular MRI for the assessment
of functional information in steady-state contrast and for viability assessment
during the inversion recovery of the magnetization. Two approaches
are introduced and discussed in detail. MOCO-MAP uses an exponential
model to recover dynamic image data, IR-CRISPI, with its low-rank plus
sparse reconstruction, is related to compressed sensing.
MOCO-MAP is a successor to model-based acceleration of parametermapping
(MAP) for the application in the myocardial region. To this end, it
was augmented with a motion correction (MOCO) step to allow exponential
fitting the signal of a still object in temporal direction. Iteratively, this
introduction of prior physical knowledge together with the enforcement of
consistency with the measured data can be used to reconstruct an image
series from distinctly shorter sampling time than the standard exam (< 3 s
opposed to about 10 s). Results show feasibility of the method as well as
detectability of delayed enhancement in the myocardium, but also significant
discrepancies when imaging cardiac function and artifacts caused already by
minor inaccuracy of the motion correction.
IR-CRISPI was developed from CRISPI, which is a real-time protocol
specifically designed for functional evaluation of image data in steady-state
contrast. With a reconstruction based on the separate calculation of low-rank
and sparse part, it employs a softer constraint than the strict exponential
model, which was possible due to sufficient temporal sampling density via
spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on
dynamic and on inversion recovery data. Thus, motion correction is rendered
unnecessary with it.
IR-CRISPI was equipped with noise suppression via spatial wavelet filtering.
A study comprising 10 patients with cardiac disease show medical
applicability. A comparison with performed traditional reference exams offer
insight into diagnostic benefits. Especially regarding patients with difficulty
to hold their breath, the real-time manner of the IR-CRISPI acquisition provides
a valuable alternative and an increase in robustness.
In conclusion, especially with IR-CRISPI in free breathing, a major acceleration
of the cardiovascular MR exam could be realized. In an acquisition
of less than 100 s, it not only includes the information of two traditional
protocols (cine and LGE), which take up more than 9.6 min, but also allows
adjustment of TI in retrospect and yields lower artifact level with similar
image quality.
In this work, accelerated non-Cartesian Magnetic Resonance Imaging (MRI) methods were established and applied to cardiovascular imaging (CMR) at different magnetic field strengths (3T and 7T).
To enable rapid data acquisition, highly efficient spiral k-space trajectories were created. In addition, hybrid sampling patterns such as the twisting radial lines (TWIRL) k-space trajectory were studied.
Imperfections of the dynamic gradient system of a MR scanner result in k-space sampling errors. Ultimately, these errors can lead to image artifacts in non-Cartesian acquisitions.
Among other reasons such as an increased reconstruction complexity, they cause the lack of spiral sequences in clinical routine compared to standard Cartesian imaging.
Therefore, the Gradient System Transfer Functions (GSTFs) of both scanners were determined and used for k-space trajectory correction in post-correction as well as in terms of a pre-emphasis.
The GSTF pre-emphasis was implemented as a fully automatic procedure, which enabled a precise correction of arbitrary gradient waveforms for double-oblique slice orientations.
Consequently, artifacts due to trajectory errors could be mitigated, which resulted in high image quality in non-Cartesian MRI.
Additionally, the GSTF correction was validated by measuring pre-emphasized spiral gradient outputs, which showed high agreement with the theoretical gradient waveforms.
Furthermore, it could be demonstrated that the performance of the GSTF correction is superior to a simple delay compensation approach.
The developed pulse sequences were applied to gated as well as real-time CMR. Special focus lied on the implementation of a spiral imaging protocol to resolve the beating heart of animals and humans in real time and free breathing.
In order to achieve real-time CMR with high spatiotemporal resolution, k-space undersampling was performed. For this reason, efficient sampling strategies were developed with the aim to facilitate compressed sensing (CS) during image reconstruction.
The applied CS approach successfully removed aliasing artifacts and yielded high-resolution cardiac image series. Image reconstruction was performed offline in all cases such that the images were not available immediately after acquisition at the scanner.
Spiral real-time CMR could be performed in free breathing, which led to an acquisition time of less than 1 minute for a whole short-axis stack.
At 3T, the results were compared to the gold standard of electrocardiogram-gated Cartesian CMR in breath hold, which revealed similar values for important cardiovascular functional and volumetric parameters.
This paves the way to an application of the developed framework in clinical routine of CMR.
In addition, the spiral real-time protocol was transferred to swallowing and speech imaging at 3T, and first images were presented.
The results were of high quality and confirm the straightforward utilization of the spiral sequence in other fields of MRI.
In general, the GSTF correction yielded high-quality images at both field strengths, 3T and 7T.
Off-resonance related blurring was mitigated by applying non-Cartesian readout gradients of short duration. At 7T, however, B1-inhomogeneity led to image artifacts in some cases.
All in all, this work demonstrated great advances in accelerating the MRI process by combining efficient, undersampled non-Cartesian k-space coverage with CS reconstruction.
Trajectory correction using the GSTF can be implemented at any scanner model and enables non-Cartesian imaging with high image quality.
Especially MRI of dynamic processes greatly benefits from the presented rapid imaging approaches.
Magnetic Resonance Imaging (MRI) is an imaging modality which provides anatomical or functional images of the human body with variable contrasts in an arbitrarily positioned slice without the need for ionizing radiation. In MRI, data are not acquired directly, but in the reciprocal image space (otherwise known as k-space) through the application of spatially variable magnetic field gradients. The k-space is made up of a grid of data points which are generally acquired in a line-by-line fashion (Cartesian imaging). After the acquisition, the k-space data are transformed into the image domain using the Fast Fourier Transformation (FFT). However, the acquisition of data is not limited to the rectilinear Cartesian sampling scheme described above. Non-Cartesian acquisitions, where the data are collected along exotic trajectories, such as radial and spiral, have been shown to be beneficial in a number of applications. However, despite their additional properties and potential advantages, working with non-Cartesian data can be complicated. The primary difficulty is that non-Cartesian trajectories are made up of points which do not fall on a Cartesian grid, and a simple and fast FFT algorithm cannot be employed to reconstruct images from non-Cartesian data. In order to create an image, the non-Cartesian data are generally resampled on a Cartesian grid, an operation known as gridding, before the FFT is performed. Another challenge for non-Cartesian imaging is the combination of unusual trajectories with parallel imaging. This thesis has presented several new non-Cartesian parallel imaging methods which simplify both gridding and the reconstruction of images from undersampled data. In Chapter 4, a novel approach which uses the concepts of parallel imaging to grid data sampled along a non-Cartesian trajectory called GRAPPA Operator Gridding (GROG) is described. GROG shifts any acquired k-space data point to its nearest Cartesian location, thereby converting non-Cartesian to Cartesian data. The only requirements for GROG are a multi-channel acquisition and a calibration dataset for the determination of the GROG weights. Chapter 5 discusses an extension of GRAPPA Operator Gridding, namely Self-Calibrating GRAPPA Operator Gridding (SC-GROG). SC-GROG is a method by which non-Cartesian data can be gridded using spatial information from a multi-channel coil array without the need for an additional calibration dataset, as required in standard GROG. Although GROG can be used to grid undersampled datasets, it is important to note that this method uses parallel imaging only for gridding, and not to reconstruct artifact-free images from undersampled data. Chapter 6 introduces a simple, novel method for performing modified Cartesian GRAPPA reconstructions on undersampled non-Cartesian k-space data gridded using GROG to arrive at a non-aliased image. Because the undersampled non-Cartesian data cannot be reconstructed using a single GRAPPA kernel, several Cartesian patterns are selected for the reconstruction. Finally, Chapter 7 discusses a novel method of using GROG to mimic the bunched phase encoding acquisition (BPE) scheme. In MRI, it is generally assumed that an artifact-free image can be reconstructed only from sampled points which fulfill the Nyquist criterion. However, the BPE reconstruction is based on the Generalized Sampling Theorem of Papoulis, which states that a continuous signal can be reconstructed from sampled points as long as the points are on average sampled at the Nyquist frequency. A novel method of generating the “bunched” data using GRAPPA Operator Gridding (GROG), which shifts datapoints by small distances in k-space using the GRAPPA Operator instead of employing zig-zag shaped gradients, is presented in this chapter. With the conjugate gradient reconstruction method, these additional “bunched” points can then be used to reconstruct an artifact-free image from undersampled data. This method is referred to as GROG-facilitated Bunched Phase Encoding, or GROG-BPE.
Der Einfluss von Aufmerksamkeit und Interferenzkontrolle auf die Verarbeitung visueller Stimuli
(2008)
Gegenstand der vorliegenden Arbeit war die Frage, inwieweit die neuronale Verarbeitung visueller Stimuli durch Prozesse der Aufmerksamkeit und des Arbeitsgedächtnisses moduliert werden kann. Darüber hinaus wurde untersucht, welche „top down“ Prozesse diese Modulation steuern. Dabei wurden zwei konkurrierende Ansichten als mögliche Erklärungsmodelle zugrunde gelegt und überprüft. Zum einen wäre es möglich, dass selektive Aufmerksamkeit zwei qualitativ unterschiedliche Mechanismen beinhaltet. Demnach würde neben dem Fokussieren auf relevante Informationen auch ein aktiver Prozess der Inhibition der Verarbeitung irrelevanter Stimuli existieren. Zum anderen ist es aber auch denkbar, dass aufgrund begrenzter Verarbeitungsressourcen das Fokussieren auf relevante Reize automatisch mit dem Nichtbeachten irrelevanter Stimuli einhergeht und nur ein Mechanismus existiert. In einem ersten Experiment wurde vorab die Alertness als ein grundlegender Prozess der Aufmerksamkeit mit der Nah-Infrarot Spektroskopie (NIRS) untersucht. Mittels eines zweigestuften Studiendesigns wurden in einem ersten Schritt für die Alertness relevante Regionen über fronto-temporalen Hirnarealen definiert. Als relevant erwiesen sich Areale des mittleren und superioren temporalen Kortex der rechten Hemisphäre und der ventrale Teil des inferioren frontalen Kortex der linken Hemisphäre. In einer zweiten Datenerhebung konnte für diese Regionen eine signifikant höhere Aktivierung während der Alertnessbedingung im Vergleich zu einer visuellen und motorischen Kontrollbedingung gefunden werden. Mit dem zweiten Experiment sollten bestehende, mit dem Elektroenzephalogramm (EEG) erhobene, Befunde zur Modulation der neuronalen Verarbeitung visueller Stimuli repliziert werden. Dies geschah mithilfe eines neu entwickelten Untersuchungsparadigmas, einer modifizierten n-back Aufgabe. Wie erwartet fand sich eine erhöhte Verarbeitung aufgaben-relevanter Reize im Vergleich zu einer perzeptuellen Kontrollbedingung. Die Verarbeitung irrelevanter Reize wurde allerdings nicht unterdrückt. Explorativ fand sich ein entsprechendes Korrelat der Aufmerksamkeitslenkung über frontalen Elektroden. In einem dritten Experiment wurde das modifizierte n-back Paradigma an die Anforderungen einer NIRS Messung angepasst, um frontale Effekte der Aufmerksamkeitslenkung direkter erfassen zu können als mit dem EEG. Wie erwartet fand sich bezüglich des Beachtens wie auch des Ignorierens von Stimuli eine Beteiligung frontaler Strukturen. Auf beachtete Stimuli folgte eine bilaterale Aktivierung des dorsolateralen präfrontalen Kortex (DL-PFK) und eine Aktivierung des linken inferioren frontalen Kortex bis hin zum prä- und postzentralen Kortex. Das Ignorieren visueller Stimuli führte zu einer weitläufigen Aktivierung des rechten präfrontalen Kortex (PFK). Eine Beteiligung des linken inferioren frontalen Gyrus an der Interferenzkontrolle konnte nicht wie erwartet nachgewiesen werden. Der Vergleich der beiden Aktivierungsmuster ergab keine signifikanten Unterschiede. Die zugrunde liegenden Prozesse des Arbeitsgedächtnisses und der Interferenzkontrolle führten also zu einer Aktivierung stark überlappender Hirnregionen. Nachdem die Ergebnisse der Experimente 2 und 3 keinerlei Hinweise auf einen aktiven Prozess der Interferenzinhibition nachweisen konnten, wurde im Experiment 4 die bisher genutzte 1-back Aufgabe durch eine schwierigere 2-back Aufgabe ersetzt. Aufgrund der erhöhten Auslastung des Arbeitsgedächtnisses sollte eine stärkere Anstrengung und damit eine verstärkte frontale Aktivierung bei der Interferenzinhibition auftreten. Diese Hypothese wurde mit einer frontalen NIRS Messung überprüft (Experiment 4a). Wie erwartet führte die erhöhte Auslastung des Arbeitsgedächtnisses zu einer verstärkten Aktivierung des PFK bezüglich beachteter Reize. Hinsichtlich ignorierter Reize fand sich allerdings keine frontale Beteiligung. Parallel erhobene EEG Daten zeigten keinen Unterschied zwischen der Verarbeitung beachteter und ignorierter Gesichter. Die Verarbeitung passiv betrachteter Gesichter war im Gegensatz zu beachteten und ignorierten Gesichtern vermindert. Im zweiten Teil der Studie (Experiment 4b) wurden erstmals die okzipitalen Effekte der Aufmerksamkeitslenkung mit der NIRS erfasst. Im Einklang mit den Ergebnissen der ersten EEG Studie (Experiment 2) fand sich zwar eine verstärkte Verarbeitung beachteter, aber keine verminderte Verarbeitung ignorierter Reize. Zusammengenommen sprechen die fehlende aktive Inhibition von Distraktorreizen im okzipitalen Kortex und die vergleichbaren neuronalen Korrelate von Prozessen des Arbeitsgedächtnisses und der Interferenzinhibition im frontalen Kortex für die Hypothese einer Aufteilung von begrenzten Verarbeitungsressourcen zugunsten beachteter Reize.
Replication-competent oncolytic viral therapies have shown great promise preclinically and in clinical trials for the treatment of various cancers. They are able to preferentially and selectively propagate in cancer cells, consequently destroying tumor tissue via cell lysis, while leaving noncancerous tissues unharmed. Currently, biopsy is the gold standard for monitoring of viral tumor colonization and oncolysis. This may be feasible in preclinical or early clinical trials; however, a noninvasive method facilitating ongoing monitoring of viral therapy is needed for human studies. The tracking of viral delivery could give clinicians the ability to assess the biodistribution of oncolytic viruses to ensure safety and correlation with treatment efficacy. This work centers on the construction and testing of a VACV strain, GLV-1h153, carrying the human sodium iodide symporter (hNIS) as a marker gene for non-invasive tracking of virus by imaging. Thus, this project aimed to help develop imaging techniques for use in clinical trials of oncolytic viral therapy. Further, the feasibility and effectiveness of virally induced targeted radiotherapy as an anti-cancer strategy was also investigated. hNIS is an intrinsic plasma membrane protein which mediates the active transport and concentration of iodide in the thyroid gland and some extra-thyroidal tissues. It is also one of several human genes currently being used as reporters in preclinical studies and has already been used in clinical studies for imaging viral replication in prostate cancer. hNIS gene transfer via viral vector may allow infected tumor cells to concentrate several carrier-free radionuclide probes such as Iodide-124 (124I), Iodide-131 (131I), and 99m-Technecium Pertechtenate (99mTcO4), which have long been approved for human use. hNIS also has the advantage of being of human origin thus minimizing immunogenicity, and its transporter based system allows intracellular signal amplification. GLV-1h153 was tested in pancreatic adenocarcinoma cell line PANC-1. GLV-1h153 infected, replicated within, and killed PANC-1 cells in cell culture as efficiently as GLV-1h68 and provided dose-dependent levels of hNIS transgene expression in infected cells. Immunofluorescence detected successful transport of the protein to the cell membrane prior to cell lysis, which enhanced dose and time-dependent intracellular uptake of 131I. In vivo, GLV-1h153 was as safe and effective as GLV-1h68 in regressing pancreatic cancer xenografts. Tumor infection by virus was confirmed via optical imaging and histology. GLV-1h153 further facilitated deep tissue imaging of virus replication in tumors via Iodide-124I positron emission tomography (PET) as well as 99mTcO4-mediated gamma scintigraphy. This was possible with both intratumoral and intravenous injection of the virus with radiouptake retained as long as 24 and 48 hours after radiotracer injection. PET image quantitation of radiouptake in tumors was found to correlate well with tissue radiouptake counts. Autoradiography of GLV-1h153-infected tumors revealed a need for presence of virus (visualized with green fluorescent protein expression), viable tissue, and adequate blood flow to enhance radiouptake in tumors. Dosimetric analysis of uptake in infected tumors displayed potential for therapeutic doses of radiotherapy to be delivered systemically to tumors. When GLV-1h153 was combined with 131I for treatment, a modest additive effect was seen as compared to GLV-1h153 alone. Therefore, GLV-1h153 is a promising new candidate for treating pancreatic cancer and noninvasively imaging viral therapy. These findings warrant further investigation into possible long term monitoring of viral therapy, as well as synergistic or additive effects of radioiodine combined with this novel treatment and imaging modality.
Bei fehlender Chemotherapie- und Strahlensensibilität stellt die Operation derzeit die einzige kurative Therapie des Nierenzellkarzinoms (NZK) dar. Dabei konnte die organerhaltende Nierentumorexstirpation sich in den letzten Jahren auch bei elektiven Indikationsstellungen zunehmend etablieren und gilt bei kleinen organbegrenzten NZK inzwischen als Methode der Wahl, auch wenn über Effektivität und Sicherheit hinsichtlich Tumorkontrolle und Patientenüberleben weiterhin diskutiert wird. Die radikale Tumornephrektomie bleibt den fortgeschrittenen Tumorstadien vorbehalten. Retrospektiv zeigt sich, dass nur dann gleichwertige onkologische Ergebnisse bei der organerhaltenden Nierentumorchirurgie im Vergleich zur radikalen Nephrektomie erzielt werden können, wenn präoperativ die Selektion eines geeigneten Patientenkollektivs erfolgt. Welche Parameter hierbei vorwiegend entscheidend waren, wurde anhand unseres Patientengutes (auch im Vergleich mit aktuellen Literaturdaten) ausgewertet. Gerade bei elektiven Fällen ist nicht zuletzt durch das Fehlen objektiver Kriterien die Grenze zwischen radikaler Tumornephrektomie und organerhaltender Nierentumorexstirpation fliessend. Oftmals ist hier im Rahmen der präoperativen Analyse eine multifaktorielle Einschätzung des einzelnen Patienten erforderlich. Besonders im Fokus stand bei der Auswertung die präoperative bildgebende Diagnostik, der bei der Indikationsstellung zugunsten einer radikalen Nephrektomie respektive einer nierenerhaltenden Tumorentfernung eine entscheidende Rolle zukommt. Ziel dieser Dissertation war es zu beurteilen, ob die präoperative Diagnostik als sichere Grundlage bei der Entscheidung der Operationstechnik gesehen werden kann und welche Nachteile aus onkologischer als auch nephrologischer Sicht jeweils bei organerhaltender Nierentumorexstirpation und radikaler Tumornephrektomie resultieren.
Mit dem hier vorgestellten Untersuchungs- und Auswertealgorithmus konnte die Myokardperfusion weitgehend automatisiert semiquantitativ und quantitativ bestimmt werden. Dafür wurden zunächst die Bilddaten segmentiert und in Signalintensitäts-Zeit-Kurven transferiert. Durch eine Basislinien- und Kontaminationskorrektur wurden Artefakte minimiert. Mit Anwendung des Parallel-Bildgebungs-Verfahrens Auto-SENSE konnte zusätzlich eine Erhöhung der Schichtanzahl erreicht werden. Durch die angewendete Basislinienkorrektur konnten Inhomogenitäten verringert werden, welche durch Verwendung einer Oberflächenspule methodenbedingt auftreten. Partialvolumeneffekte, die durch die Morphologie des Herzens insbesondere basis- und spitzennah auftraten, führten durch eine Mischung aus KM-Anflutung im Myokard und Kontamination aus dem Ventrikellumen zu einer Beeinflussung der Perfusionsergebnisse. Durch die Verwendung der vorgestellten Kontaminationskorrektur konnten diese Artefakte erheblich minimiert werden. Die so errechneten Perfusionswerte korrelierten gut mit den in der Literatur angegebenen Daten, welche sowohl in tierexperimentellen als auch Probanden- und auch Patientenstudien mit unterschiedlichen Modalitäten ermittelt wurden. Eine regionale Heterogenität konnte nicht signifikant nachgewiesen werden. Molekular-physiologische Untersuchungen legen zwar nahe, dass es diese Heterogenität gibt, die regionale Verteilung der Perfusion wird jedoch kontrovers und noch keinesfalls abschließend in der Literatur diskutiert. Durch Anwendung von Auto-SENSE konnte mit einer Erhöhung der Schichtanzahl bei gleichbleibender Schichtdicke das gesamte linksventrikuläre Myokard untersucht werden. Trotz verringertem SNR waren die Ergebnisse vergleichbar mit der konventionellen Turbo-FLASH-Technik. Ob das Potential der Parallelbildgebung für eine Abdeckung des gesamten Herzens oder für eine höhere Auflösung von 3-4 Schichten pro Untersuchungen genutzt werden soll, ist in der aktuellen Literatur noch Gegenstand der Diskussion. Die hochaufgelösten Untersuchungen scheinen jedoch derzeit vorteilhafter aufgrund geringerer Partialvolumeneffekte sowie der besseren Beurteilbarkeit einer subendokardialen Zone und eines transmuralen Perfusionsgradienten. Die MR-Perfusionsbildgebung ist ein aktives und rasch wachsendes Gebiet innerhalb der kardialen Bildgebung mit großem Entwicklungspotential. Durch Einbindung in ein umfassendes Herz-MR-Untersuchungsprotokoll (z.B. Morphologie, Kinetik, evtl. MR-Koronarangiographie) ist in einem Untersuchungsgang eine umfassende Diagnostik bei Patienten mit Verdacht auf KHK möglich.
Entwicklung und Optimierung von Bildgebungssequenzen für die 1H-Magnetresonanztomographie der Lunge
(2007)
No abstract available
Hintergrund: Die Alzheimer-Erkrankung ist die häufigste neurodegenerative Erkrankung. Da es zurzeit für sie noch keine Heilung gibt, richtet sich das Hauptaugenmerk auf eine möglichst frühe Diagnose und die Behandlung mit krankheitsverzögernden Medikamenten. Vor allem die funktionelle Bildgebung gilt im Bereich der Frühdiagnose als vielversprechend. Neben dem Gedächtnis werden die visuell-räumliche Informationsverarbeitung, exekutive Funktionen und Aufmerksamkeitsprozesse untersucht. Hierbei zeigen sich zentralnervöse Aktivierungsauffälligkeiten in kortikalen Zielregionen etwa im präfrontalen und im parietalen Kortex. Verlaufsuntersuchungen konzentrieren sich vor allem darauf aus der Gehirnaktivierung Vorhersagen über kognitive Veränderungen bei älteren Personen mit und ohne Gedächtnisstörung treffen zu können. Nur wenige Studien erfassen dabei jedoch die Gehirnaktivierung zu mehreren Messzeitpunkten. Gerade für große Stichproben und wiederholte Messungen könnte die funktionelle Nahinfrarotspektroskopie (fNIRS) sich als Alternative zur Magnetresonanztomographie anbieten. Ziel: Ziel der Studie war es, mit fNIRS und ereigniskorrelierten Potentialen funktionelle Unterschiede zwischen Alzheimer-Patienten und gleichaltrigen Kontrollen in mehreren Funktionsbereichen darzustellen und ihre Veränderung über den Zeitraum eines Jahres zu verfolgen. Zum ersten Mal sollte im Rahmen einer prospektiven Untersuchung mit fNIRS geprüft werden ob kortikale Aktivierungen zur Vorhersage von neuropsychologischen Testwerten genutzt werden können. Zusätzlich stellte sich die Frage, ob fNIRS für Verlaufsuntersuchungen an älteren Stichproben geeignet ist. Methoden: Im Rahmen der vorliegenden Arbeit wurden zum ersten Messzeitpunkt (T1) 73 Patienten und 71 Kontrollen mit vier Paradigmen in den drei Funktionsbereichen visuell-räumliche Informationsverarbeitung, exekutive Funktionen und zentralnervöse Filtermechanismen mit fNIRS und ereigniskorrelierten Potentialen gemessen. Die Probanden durchliefen eine Line Orientation Aufgabe, zwei Versionen einer Wortflüssigkeitsaufgabe (phonologisch und semantisch) und das P50-Doppelklickparadigma. Zielparameter waren dabei die aufgabenbezogene Aktivierung im parietalen Kortex, im dorsolateralen Präfrontalkortex (DLPFC) und das sensorische Gating, gemessen durch die P50-Supression nach wiederholter Reizdarbietung. Zusätzlich wurden zwei typische Tests zur Demenzdiagnostik (MMST und DemTect) erhoben. Die zweite Messung (T2) fand nach 12 Monaten statt und lief identisch zur ersten Untersuchung ab. Zu T2 konnten 14 Patienten und 51 Kontrollen erneut rekrutiert werden. Ergebnisse: Zu T1 konnte mit fNIRS ein Aktivierungsdefizit für Patienten im DLPFC während der phonologischen Wortflüssigkeitsaufgabe und im rechten Parietalkortex während der Line Orientation Aufgabe festgestellt werden. Für die semantische Wortflüssigkeitsaufgabe und das sensorische Gating zeigten sich keine zentralnervösen Unterschiede. Über das Jahr hinweg nahm die aufgabenbezogene Aktivierung der Patienten im linken DLPFC für beide Versionen der Wortflüssigkeitsaufgabe deutlich ab, während gleichaltrige Kontrollpersonen keine kortikalen Veränderungen zeigten. Zu T2 war das sensorische Gating der Patienten außerdem deutlich schlechter im Vergleich zu gesunden Kontrollen. Die Veränderungen der Oxygenierung während der Wortflüssigkeitsaufgabe konnten für gesunde Kontrollen Verschlechterungen im MMST und im DemTect vorhersagen. Vor allem ein Verlust der Lateralisierung ging mit einem Abfall in den kognitiven Tests einher. Schlussfolgerung: Spezifische Defizite in der kortikalen Aktivierung konnten bei Alzheimer-Patienten mit fNIRS beobachtet und genauer beschrieben werden. Auch die Veränderung im Verlauf eines Jahres ließ sich mit dieser Methode verfolgen. Für Längsschnittuntersuchungen, die sich mit der kortikalen Aktivierung als Prädiktor für dementielle Entwicklungen beschäftigen, bietet sich fNIRS somit als praktische Alternative zur fMRT an, zumal die gemessenen Veränderungen in der Oxygenierung auch prognostischen Wert für ältere Kontrollpersonen besaßen. Vor allem die funktionelle Lateralisierung in frontalen Kortexbereichen scheint als Prädiktor kognitiver Leistungen im Alter von Bedeutung zu sein.
The present work investigated the neural mechanisms underlying cognitive inhibition/thought suppression in Anderson’s and Green’s Think/No-Think paradigm (TNT), as well as different variables influencing these mechanisms at the cognitive, the neurophysiological, the electrophysiological and the molecular level. Neurophysiological data collected with fNIRS and fMRI have added up to the existing evidence of a fronto-hippocampal network interacting during the inhibition of unwanted thoughts. Some evidence has been presented suggesting that by means of external stimulation of the right dlPFC through iTBS thought suppression might be improved, providing further evidence for an implication of this region in the TNT. A combination of fNIRS with ERP has delivered evidence of a dissociation of early condition-independent attentional and later suppression-specific processes within the dlPFC, both contributing to suppression performance. Due to inconsistencies in the previous literature it was considered how stimulus valence would influence thought suppression by manipulating the emotional content of the to-be-suppressed stimuli. Findings of the current work regarding the ability to suppress negative word or picture stimuli have, however, been inconclusive as well. It has been hypothesized that performance in the TNT might depend on the combination of valence conditions included in the paradigm. Alternatively, it has been suggested that inconsistent findings regarding the suppression of negative stimuli or suppression at all might be due to certain personality traits and/or genetic variables, found in the present work to contribute to thought inhibition in the TNT. Rumination has been shown to be a valid predictor of thought suppression performance. Increased ruminative tendencies led to worse suppression performance which, in the present work, has been linked to less effective recruitment of the dlPFC and in turn less effective down-regulation of hippocampal activity during suppression trials. Trait anxiety has also been shown to interrupt thought suppression despite higher, however, inefficient recruitment of the dlPFC. Complementing the findings regarding ruminative tendencies and decreased thought inhibition a functional polymorphism in the KCNJ6 gene, encompassing a G-to-A transition, has been shown to disrupt thought suppression despite increased activation of the dlPFC. Through the investigation of thought suppression at different levels, the current work adds further evidence to the idea that the TNT reflects an executive control mechanism, which is sensitive to alterations in stimulus valence to some extent, neurophysiological functioning as indicated by its sensitivity to iTBS, functional modulations at the molecular level and personality traits, such as rumination and trait anxiety.