Refine
Has Fulltext
- yes (22)
Is part of the Bibliography
- yes (22)
Year of publication
Document Type
- Journal article (14)
- Doctoral Thesis (7)
- Review (1)
Keywords
- P300 (22) (remove)
Institute
Brain-computer interfaces (BCIs) can serve as muscle independent communication aids. Persons, who are unable to control their eye muscles (e.g., in the completely locked-in state) or have severe visual impairments for other reasons, need BCI systems that do not rely on the visual modality. For this reason, BCIs that employ auditory stimuli were suggested. In this study, a multiclass BCI spelling system was implemented that uses animal voices with directional cues to code rows and columns of a letter matrix. To reveal possible training effects with the system, 11 healthy participants performed spelling tasks on 2 consecutive days. In a second step, the system was tested by a participant with amyotrophic lateral sclerosis (ALS) in two sessions. In the first session, healthy participants spelled with an average accuracy of 76% (3.29 bits/min) that increased to 90% (4.23 bits/min) on the second day. Spelling accuracy by the participant with ALS was 20% in the first and 47% in the second session. The results indicate a strong training effect for both the healthy participants and the participant with ALS. While healthy participants reached high accuracies in the first session and second session, accuracies for the participant with ALS were not sufficient for satisfactory communication in both sessions. More training sessions might be needed to improve spelling accuracies. The study demonstrated the feasibility of the auditory BCI with healthy users and stresses the importance of training with auditory multiclass BCIs, especially for potential end-users of BCI with disease.
Gaze-independent brain-computer interfaces (BCIs) are a possible communication channel for persons with paralysis. We investigated if it is possible to use auditory stimuli to create a BCI for the Japanese Hiragana syllabary, which has 46 Hiragana characters. Additionally, we investigated if training has an effect on accuracy despite the high amount of different stimuli involved. Able-bodied participants (N = 6) were asked to select 25 syllables (out of fifty possible choices) using a two step procedure: First the consonant (ten choices) and then the vowel (five choices). This was repeated on 3 separate days. Additionally, a person with spinal cord injury (SCI) participated in the experiment. Four out of six healthy participants reached Hiragana syllable accuracies above 70% and the information transfer rate increased from 1.7 bits/min in the first session to 3.2 bits/min in the third session. The accuracy of the participant with SCI increased from 12% (0.2 bits/min) to 56% (2 bits/min) in session three. Reliable selections from a 10 × 5 matrix using auditory stimuli were possible and performance is increased by training. We were able to show that auditory P300 BCIs can be used for communication with up to fifty symbols. This enables the use of the technology of auditory P300 BCIs with a variety of applications.
Brain-computer interfaces (BCIs) could provide a muscle-independent communication channel to persons with severe paralysis by translating brain activity into device commands. As a means of communication, in particular BCIs based on event-related potentials (ERPs) as control signal have been researched. Most of these BCIs rely on visual stimulation and have been investigated with healthy participants in controlled laboratory environments. In proof-of-principle studies targeted end users gained control over BCI systems; however, these systems are not yet established as an assistive technology for persons who would most benefit from them. The main aim of this thesis is to advance the usability of ERP-BCIs for target users. To this end, five studies with BCIs have been conducted that enabled users to communicate by focusing their attention on external stimuli.
Two studies were conducted in order to demonstrate the advantages and to further improve the practical application of visual BCIs. In the first study, mental workload was experimentally manipulated during prolonged BCI operation. The study showed the robustness of the visual ERP-BCI since users maintained a satisfactory level of control despite constant distraction in the form of background noise. Moreover, neurophysiological markers that could potentially serve as indicators of high mental workload or fatigue were revealed. This is a first step towards future applications in which the BCI could adapt to the mental state of the user (e.g. pauses if high mental workload is detected to prevent false selections). In the second study, a head-mounted display (HMD), which assures that stimuli are presented in the field of view of the user, was evaluated. High accuracies and information transfer rates, similar to a conventional display, were achieved by healthy participants during a spelling task. Furthermore, a person in the locked-in state (LIS) gained control over the BCI using the HMD. The HMD might be particularly suited for initial communication attempts with persons in the LIS in situations, where mounting a conventional monitor is difficult or not feasible.
Visual ERP-BCIs could prove valuable for persons with residual control over eye muscles and sufficient vision. However, since a substantial number of target users have limited control over eye movements and/or visual impairments, BCIs based on non-visual modalities are required. Therefore, a main aspect of this thesis was to improve an auditory paradigm that should enable motor impaired users to spell by focusing attention on different tones. The two conducted studies revealed that healthy participants were able to achieve high spelling performance with the BCI already in the first session and stress the importance of the choice of the stimulus material. The employed natural tones resulted in an increase in performance compared to a previous study that used artificial tones as stimuli. Furthermore, three out of five users with a varying degree of motor impairments could gain control over the system within the five conducted sessions. Their performance increased significantly from the first to the fifth session - an effect not previously observed for visual ERP-BCIs. Hence, training is particularly important when testing auditory multiclass BCIs with potential users.
A prerequisite for user satisfaction is that the BCI technology matches user requirements. In this context, it is important to compare BCIs with already established assistive technology. Thus, the fifth study of this dissertation evaluated gaze dependent methods (EOG, eye tracking) as possible control signals for assistive technology and a binary auditory BCI with a person in the locked-in state. The study participant gained control over all tested systems and rated the ease of use of the BCI as the highest among the tested alternatives, but also rated it as the most tiring due to the high amount of attention that was needed for a simple selection. Further efforts are necessary to simplify operation of the BCI.
The involvement of end users in all steps of the design and development process of BCIs will increase the likelihood that they can eventually be used as assistive technology in daily life. The work presented in this thesis is a substantial contribution towards the goal of re-enabling communication to users who cannot rely on motor activity to convey their thoughts.
Brain–computer interfaces (BCIs) enable paralyzed patients to communicate; however, up to date, no creative expression was possible. The current study investigated the accuracy and user-friendliness of P300-Brain Painting, a new BCI application developed to paint pictures using brain activity only. Two different versions of the P300-Brain Painting application were tested: A colored matrix tested by a group of ALS-patients (n = 3) and healthy participants (n = 10), and a black and white matrix tested by healthy participants (n = 10). The three ALS-patients achieved high accuracies; two of them reaching above 89% accuracy. In healthy subjects, a comparison between the P300-Brain Painting application (colored matrix) and the P300-Spelling application revealed significantly lower accuracy and P300 amplitudes for the P300-Brain Painting application. This drop in accuracy and P300 amplitudes was not found when comparing the P300-Spelling application to an adapted, black and white matrix of the P300-Brain Painting application. By employing a black and white matrix, the accuracy of the P300-Brain Painting application was significantly enhanced and reached the accuracy of the P300-Spelling application. ALS-patients greatly enjoyed P300-Brain Painting and were able to use the application with the same accuracy as healthy subjects. P300-Brain Painting enables paralyzed patients to express themselves creatively and to participate in the prolific society through exhibitions.
Background:
Accidents or neurodegenerative diseases like amyotrophic lateral sclerosis (ALS) can lead to progressing, extensive, and complete paralysis leaving patients aware but unable to communicate (locked-in state). Brain-computer interfaces (BCI) based on electroencephalography represent an important approach to establish communication with these patients. The most common BCI for communication rely on the P300, a positive deflection arising in response to rare events. To foster broader application of BCIs for restoring lost function, also for end-users with impaired vision, we explored whether there were specific time windows during the day in which a P300 driven BCI should be preferably applied.
Methods:
The present study investigated the influence of time of the day and modality (visual vs. auditory) on P300 amplitude and latency. A sample of 14 patients (end-users) with ALS and 14 healthy age matched volunteers participated in the study and P300 event-related potentials (ERP) were recorded at four different times (10, 12 am, 2, & 4 pm) during the day.
Results:
Results indicated no differences in P300 amplitudes or latencies between groups (ALS patients v. healthy participants) or time of measurement. In the auditory condition, latencies were shorter and amplitudes smaller as compared to the visual condition.
Conclusion:
Our findings suggest applicability of EEG/BCI sessions in patients with ALS throughout normal waking hours. Future studies using actual BCI systems are needed to generalize these findings with regard to BCI effectiveness/efficiency and other times of day.
Cognitive Processing in Non-Communicative Patients: What Can Event-Related Potentials Tell Us?
(2016)
Event-related potentials (ERP) have been proposed to improve the differential diagnosis of non-responsive patients. We investigated the potential of the P300 as a reliable marker of conscious processing in patients with locked-in syndrome (LIS). Eleven chronic LIS patients and 10 healthy subjects (HS) listened to a complex-tone auditory oddball paradigm, first in a passive condition (listen to the sounds) and then in an active condition (counting the deviant tones). Seven out of nine HS displayed a P300 waveform in the passive condition and all in the active condition. HS showed statistically significant changes in peak and area amplitude between conditions. Three out of seven LIS patients showed the P3 waveform in the passive condition and five of seven in the active condition. No changes in peak amplitude and only a significant difference at one electrode in area amplitude were observed in this group between conditions. We conclude that, in spite of keeping full consciousness and intact or nearly intact cortical functions, compared to HS, LIS patients present less reliable results when testing with ERP, specifically in the passive condition. We thus strongly recommend applying ERP paradigms in an active condition when evaluating consciousness in non-responsive patients.
Background and Objectives: Cycloid psychoses are characterized by polymorphic symptomatology with intraphasic bipolarity, a remitting and recurrent course and favourable prognosis. Perris and Brocicington (P&B) described the first set of operational criteria that were partly incorporated in ICD-10. The present study investigates psychopathological profiles according to the P&B criteria and the original descriptions by Leonhard, both against the background of the criteria from the prevailing international classification systems.
Methods: Eighty patients with psychotic disorders were recruited and assessed with various psychometric instruments at baseline and after six weeks of antipsychotic treatment in order to investigate the presence of cycloid psychoses according to Leonhard (LCP) and the effect of treatment with antipsychotics. The overlap between LCP and DSM-IV Brief Psychotic Disorder (BPD), ICD Acute Polymorphic Psychotic Disorder (APP) and P&B criteria was calculated.
Results: Using P&B criteria and a symptom checklist adapted from the original descriptions by Leonhard, 14 and 12 cases of cycloid psychosis were identified respectively reflecting a prevalence of 15-18%. Small though significant concordance rates were found between LCP and both DSM-BPD and ICD-APP. Concordance between LCP and P&B criteria was also significant, but modest.
Conclusions: This study demonstrates that LCP can be identified in a substantial number of patients with psychotic disorders. Cycloid psychoses are not adequately covered in current classification systems and criteria. Since they are demonstrated to have a specific psychopathological profile, relapsing course and favourable prognosis, it is advocated to include these psychoses in daily differential diagnostic procedures.
Recent research suggests that the P3b may be closely related to the activation of the locus coeruleus-norepinephrine (LC-NE) system. To further study the potential association, we applied a novel technique, the non-invasive transcutaneous vagus nerve stimulation (tVNS), which is speculated to increase noradrenaline levels. Using a within-subject cross-over design, 20 healthy participants received continuous tVNS and sham stimulation on two consecutive days (stimulation counterbalanced across participants) while performing a visual oddball task. During stimulation, oval non-targets (standard), normal-head (easy) and rotated-head (difficult) targets, as well as novel stimuli (scenes) were presented. As an indirect marker of noradrenergic activation we also collected salivary alpha-amylase (sAA) before and after stimulation. Results showed larger P3b amplitudes for target, relative to standard stimuli, irrespective of stimulation condition. Exploratory post hoc analyses, however, revealed that, in comparison to standard stimuli, easy (but not difficult) targets produced larger P3b (but not P3a) amplitudes during active tVNS, compared to sham stimulation. For sAA levels, although main analyses did not show differential effects of stimulation, direct testing revealed that tVNS (but not sham stimulation) increased sAA levels after stimulation. Additionally, larger differences between tVNS and sham stimulation in P3b magnitudes for easy targets were associated with larger increase in sAA levels after tVNS, but not after sham stimulation. Despite preliminary evidence for a modulatory influence of tVNS on the P3b, which may be partly mediated by activation of the noradrenergic system, additional research in this field is clearly warranted. Future studies need to clarify whether tVNS also facilitates other processes, such as learning and memory, and whether tVNS can be used as therapeutic tool.
Einfluss der Reizdarbietung auf die elektrophysiologischen Korrelate der motorischen Steuerung
(2003)
In dieser Arbeit wurden die motorische Steuerung und ihre vermuteten elektrophysiologischen Korrelate (N200, P300 und NGA) näher untersucht. Dazu wurden fünf verschiedene Paradigmen (Continuous Performance Tests, CPTs)an 23 gesunden Probanden durchgeführt und die ereigniskorrelierten Potentiale aufgezeichnet. Die CPTs unterschieden sich jeweils in der Art der Reizdarbietung (visuelle/akustische Modalität, Präsentationsdauer, Inter-Stimulus-Intervall). Die Ergebnisse dieser Studie deuten auf einen Zusammenhang der elektrophysiologischen Parameter mit der motorischen Steuerung hin. Die elektrophysiologischen Unterschiede zwischen der Ausführung (Go) und der Hemmung (NoGo) einer vorbereiteten motorischen Antwort sind stabil und zeigen, dass ihnen unterschiedliche Prozesse zugrunde liegen.
Motivation moderately influences brain–computer interface (BCI) performance in healthy subjects when monetary reward is used to manipulate extrinsic motivation. However, the motivation of severely paralyzed patients, who are potentially in need for BCI, could mainly be internal and thus, an intrinsic motivator may be more powerful. Also healthy subjects who participate in BCI studies could be internally motivated as they may wish to contribute to research and thus extrinsic motivation by monetary reward would be less important than the content of the study. In this respect, motivation could be defined as “motivation-to-help.” The aim of this study was to investigate, whether subjects with high motivation for helping and who are highly empathic would perform better with a BCI controlled by event-related potentials (P300-BCI). We included N = 20 healthy young participants naïve to BCI and grouped them according to their motivation for participating in a BCI study in a low and highly motivated group. Motivation was further manipulated with interesting or boring presentations about BCI and the possibility to help patients. Motivation for helping did neither influence BCI performance nor the P300 amplitude. Post hoc, subjects were re-grouped according to their ability for perspective taking. We found significantly higher P300 amplitudes on parietal electrodes in participants with a low ability for perspective taking and therefore, lower empathy, as compared to participants with higher empathy. The lack of an effect of motivation on BCI performance contradicts previous findings and thus, requires further investigation. We speculate that subjects with higher empathy who are good perspective takers with regards to patients in potential need of BCI, may be more emotionally involved and therefore, less able to allocate attention on the BCI task at hand.