Refine
Has Fulltext
- yes (60)
Is part of the Bibliography
- yes (60)
Year of publication
Document Type
- Doctoral Thesis (59)
- Journal article (1)
Keywords
- NMR-Tomographie (60) (remove)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (19)
- Physikalisches Institut (19)
- Institut für Anorganische Chemie (5)
- Medizinische Klinik und Poliklinik I (5)
- Graduate School of Life Sciences (3)
- Neurochirurgische Klinik und Poliklinik (2)
- Neurologische Klinik und Poliklinik (2)
- Theodor-Boveri-Institut für Biowissenschaften (2)
- Institut für Hygiene und Mikrobiologie (1)
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen (1)
Sonstige beteiligte Institutionen
Magnetic Resonance Imaging (MRI) is a non-invasive medical imaging technique, that is rou- tinely used in clinical practice for detection and diagnosis of a wide range of different diseases. In MRI, no ionizing radiation is used, making even repeated application unproblematic. This is an important advantage over other common imaging methods such as X-rays and Computer To- mography. One major drawback of MRI, however, are long acquisition times and associated high costs of experiments. Since the introduction of MRI, several important technical developments have been made to successfully reduce acquisition times. In this work, novel approaches were developed to increase the efficiency of MRI acquisitions.
In Chapter 4, an improved radial turbo spin-echo (TSE) combined acquisition and reconstruction strategy was introduced. Cartesian turbo spin-echo sequences [3] are widely used especially for the detection and diagnosis of neurological pathologies, as they provide high SNR images with both clinically important proton density and T2 contrasts. TSE acquisitions combined with radial sampling are very efficient, since it is possible to obtain a number of ETL images with different contrasts from a single radial TSE measurement [56–58]. Conventionally, images with a particular contrast are obtained from both radial and Cartesian TSE acquisitions by combining data from different echo times into a single image. In the radial case, this can be achieved by employing k-space weighted image contrast (KWIC) reconstruction. In KWIC, the center region of k-space is filled exclusively with data belonging to the desired contrast while outer regions also are assembled with data acquired at other echo times. However, this data sharing leads to mixed contrast contributions to both Cartesian and radial TSE images. This is true especially for proton density weighted images and therefore may reduce their diagnostic value.
In the proposed method, an adapted golden angle reordering scheme is introduced for radial TSE acquisitions, that allows a free choice of the echo train length and provides high flexibility in image reconstruction. Unwanted contrast contaminations are greatly reduced by employing a narrow-band KWIC filter, that restricts data sharing to a small temporal window around the de- sired echo time. This corresponds to using fewer data than required for fully sampled images and consequently leads to images exhibiting aliasing artifacts. In a second step, aliasing-free images are obtained using parallel imaging. In the neurological examples presented, the CG-SENSE algorithm [42] was chosen due to its stable convergence properties and its ability to reconstruct arbitrarily sampled data. In simulations as well as in different in vivo neurological applications, no unwanted contrast contributions could be observed in radial TSE images reconstructed with the proposed method. Since this novel approach is easy to implement on today’s scanners and requires low computational power, it might be valuable for the clinical breakthrough of radial TSE acquisitions.
In Chapter 5, an auto-calibrating method was introduced to correct for stimulated echo contribu- tions to T2 estimates from a mono-exponential fit of multi spin-echo (MSE) data. Quantification of T2 is a useful tool in clinical routine for the detection and diagnosis of diseases as well as for tis- sue characterization. Due to technical imperfections, refocusing flip angles in a MSE acquisition deviate from the ideal value of 180○. This gives rise to significant stimulated echo contributions to the overall signal evolution. Therefore, T2 estimates obtained from MSE acquisitions typically are notably higher than the reference. To obtain accurate T2 estimates from MSE acquisitions, MSE signal amplitudes can be predicted using the extended phase graph (EPG, [23, 24]) algo- rithm. Subsequently, a correction factor can be obtained from the simulated EPG T2 value and applied to the MSE T2 estimates. However, EPG calculations require knowledge about refocus- ing pulse amplitudes, T2 and T1 values and the temporal spacing of subsequent echoes. While the echo spacing is known and, as shown in simulations, an approximate T1 value can be assumed for high ratios of T1/T2 without compromising accuracy of the results, the remaining two parameters are estimated from the data themselves. An estimate for the refocusing flip angle can be obtained from the signal intensity ratio of the second to the first echo using EPG. A conventional mono- exponential fit of the MSE data yields a first estimate for T2. The T2 correction is then obtained iteratively by updating the T2 value used for EPG calculations in each step. For all examples pre- sented, two iterations proved to be sufficient for convergence. In the proposed method, a mean flip angle is extracted across the slice. As shown in simulations, this assumption leads to greatly reduced deviations even for more inhomogeneous slice profiles. The accuracy of corrected T2 values was shown in experiments using a phantom consisting of bottles filled with liquids with a wide range of different T2 values. While T2 MSE estimates were shown to deviate significantly from the spin-echo reference values, this is not the case for corrected T2 values. Furthermore, applicability was demonstrated for in vivo neurological experiments.
In Chapter 6, a new auto-calibrating parallel imaging method called iterative GROG was pre- sented for the reconstruction of non-Cartesian data. A wide range of different non-Cartesian schemes have been proposed for data acquisition in MRI, that present various advantages over conventional Cartesian sampling such as faster acquisitions, improved dynamic imaging and in- trinsic motion correction. However, one drawback of non-Cartesian data is the more complicated reconstruction, which is ever more problematic for non-Cartesian parallel imaging techniques. Iterative GROG uses Calibrationless Parallel Imaging by Structured Low-Rank Matrix Completion (CPI) for data reconstruction. Since CPI requires points on a Cartesian grid, it cannot be used to directly reconstruct non-Cartesian data. Instead, Grappa Operator Gridding (GROG) is employed in a first step to move the non-Cartesian points to the nearest Cartesian grid locations. However, GROG requires a fully sampled center region of k-space for calibration. Combining both methods in an iterative scheme, accurate GROG weights can be obtained even from highly undersampled non-Cartesian data. Subsequently, CPI can be used to reconstruct either full k- space or a calibration area of arbitrary size, which can then be employed for data reconstruction with conventional parallel imaging methods.
In Chapter 7, a new 2D sampling scheme was introduced consisting of multiple oscillating effi- cient trajectories (MOET), that is optimized for Compressed Sensing (CS) reconstructions. For successful CS reconstruction of a particular data set, some requirements have to be met. First, ev- ery data sample has to carry information about the whole object, which is automatically fulfilled for the Fourier sampling employed in MRI. Additionally, the image to be reconstructed has to be sparse in an arbitrary domain, which is true for a number of different applications. Last, data sam- pling has to be performed in an incoherent fashion. For 2D imaging, this important requirement of CS is difficult to achieve with conventional Cartesian and non-Cartesian sampling schemes. Ra- dial sampling is often used for CS reconstructions of dynamic data despite the streaking present in undersampled images. To obtain incoherent aliasing artifacts in undersampled images while at the same time preserving the advantages of radial sampling for dynamic imaging, MOET com- bines radial spokes with oscillating gradients of varying amplitude and alternating orientation orthogonal to the readout direction. The advantage of MOET over radial sampling in CS re- constructions was demonstrated in simulations and in in vivo cardiac imaging. MOET provides superior results especially when used in CS reconstructions with a sparsity constraint directly in image space. Here, accurate results could be obtained even from few MOET projections, while the coherent streaking artifacts present in the case of radial sampling prevent image recovery even for smaller acceleration factors. For CS reconstructions of dynamic data with sparsity constraint in xf-space, the advantage of MOET is smaller since the temporal reordering is responsible for an important part of incoherency. However, as was shown in simulations of a moving phantom and in the reconstruction of ungated cardiac data, the additional spatial incoherency provided by MOET still leads to improved results with higher accuracy and may allow reconstructions with higher acceleration factors.
Das Signal-zu-Rausch-Verhältnis (SNR) stellt bei modernen Bildgebungstechniken in der Magnetresonanz-Tomographie heutzutage oftmals die entscheidende Limitation dar. Eine Verbesserung durch Modifikation der Hardware ist kostspielig und führt meistens zu einer Verstärkung anderer Probleme, wie zum Beispiel erhöhte Energiedeposition ins Gewebe. Im Gegensatz dazu ist Dichtegewichtung eine Methode, die eine SNR-Erhöhung durch Modifikation der Aufnahmetechnik ermöglicht. In der MR-Bildgebung erfolgt oftmals eine retrospektive Filterung des aufgenommenen Signalverlaufs, beispielsweise zur Artefaktreduktion. Damit einhergehend findet eine Veränderung der Modulationstransferfunktion (MTF) bzw. ihrer Fouriertransformierten, der räumlichen Antwortfunktion (SRF), statt. Optimales SNR wird nach dem Matched Filter-Theorem erzielt, wenn die nachträgliche Filterung dem aufgenommenen Signalverlauf proportional ist. Dies steht dem Ziel der Artefaktreduktion entgegen. Bei Dichtegewichtung steht durch nicht-kartesische Abtastung des k-Raums mit der k-Raum-Dichte ein zusätzlicher Freiheitsgrad zur Verfügung. Dieser ermöglicht es, im Falle eines konstanten Signalverlaufs eine gewünschte MTF ohne Filterung zu erreichen. Bei veränderlichem Signalverlauf kann ein SNR Matched Filter angewendet werden, dessen negative Einflüsse auf die MTF durch Dichtegewichtung kompensiert werden. Somit ermöglicht Dichtegewichtung eine vorgegebene MTF und gleichzeitig ein optimales SNR. In der vorliegenden Arbeit wurde Dichtegewichtung erstmals bei den schnellen Multi-Echo-Sequenzen Turbo-Spin-Echo und Echoplanar-Bildgebung (EPI) angewendet. Im Gegensatz zu bisherigen Implementierungen muss hier der Signalabfall durch T2- bzw. T2*-Relaxation berücksichtigt werden. Dies führt dazu, dass eine prospektiv berechnete dichtegewichtete Verteilung nur bei einer Relaxationszeit optimal ist. Bei Geweben mit abweichenden Relaxationszeiten können sich wie auch bei den kartesischen Varianten dieser Sequenzen Änderungen an SRF und SNR ergeben. Bei dichtegewichteter Turbo-Spin-Echo-Bildgebung des Gehirns konnte mit den gewählten Sequenzparametern ein SNR-Vorteil von 43 % gegenüber der kartesischen Variante erzielt werden. Die Akquisition wurde dabei auf die T2-Relaxationszeit von weißer Substanz optimiert. Da die meisten Gewebe im Gehirn eine ähnliche Relaxationszeit aufweisen, blieb der visuelle Gesamteindruck identisch zur kartesischen Bildgebung. Der SNR-Gewinn konnte in der dichtegewichteten Implementierung zur Messzeithalbierung genutzt werden. Dichtegewichtete EPI weist eine hohe Anfälligkeit für geometrische Verzerrungen, welche durch Inhomogenitäten des Hauptmagnetfeldes verursacht werden, auf. Die Verzerrungen konnten erfolgreich mit einer Conjugate Phase-Methode korrigiert werden. Dazu muss die räumliche Verteilung der Feldinhomogenitäten bekannt sein. Dazu ist zusätzlich zur eigentlichen EPI-Aufnahme die zeitaufwendige Aufnahme einer sogenannten Fieldmap erforderlich. Im Rahmen dieser Arbeit konnte eine Methode entwickelt werden, welche die zur Erlangung einer Fieldmap notwendige Aufnahmedauer auf wenige Sekunden reduziert. Bei dieser Art der Fieldmap-Aufnahme müssen jedoch durch Atmung hervorgerufene Effekte auf die Bildphase berücksichtigt werden. Die Fieldmap-Genauigkeit kann durch Aufnahme unter Atempause, Mittelung oder retrospektiver Phasenkorrektur erhöht werden. Für die gewählten EPI-Sequenzparameter wurde mit Dichtegewichtung gegenüber der kartesischen Variante ein SNR-Gewinn von 14 % erzielt. Anhand einer funktionellen MRT (fMRI)-Fingertapping-Studie konnte demonstriert werden, dass die SNR-Steigerung auch zu einer signifikant erhöhten Aktivierungsdetektion in Teilen der Hirnareale führt, die bei der Fingerbewegung involviert sind. Die Verwendung von zusätzlicher EPI-Phasenkorrektur und iterativer Optimierung der dichtegewichteten k-Raum-Abtastung führt zu weiteren Verbesserungen der dichtegewichteten Bildgebung mit Multi-Echo-Sequenzen.
Myocardial infarction (MI) is a leading cause of death worldwide. Timely restoration of coronary blood flow to ischemic myocardium significantly reduces acute infarct mortality and attenuates ventricular remodeling. However, surviving MI patients frequently develop heart failure, which is associated with reduced quality of life, high mortality rate (10% annually), as well as high healthcare expenditures. The main processes involved in the evolution of heart failure post-MI are the great loss of contractile cardiomyocytes during ischemia-reperfusion and the subsequent complex structural and functional alterations, which are rooted in modifications at molecular and cellular levels in both the infarcted and non-infarcted myocardium. However, we still lack efficient treatments to prevent the development and progression of left ventricular remodeling. The improved survival rate of acute MI patients combined with the lack of effective therapy for post-MI remodeling contributes to the high prevalence of heart failure. Cardiac Magnetic Resonance Imaging (MRI) is an important tool for diagnosis and assessment of MI. With the advancement of this technology, the frontier of MRI has been extended to probing molecular and cellular events in vivo and non-invasively. In combination with assessment of morphology and function, the visualization of essential molecular and cellular markers in vivo could provide comprehensive, multifaceted views of the healing process in infarcted hearts, which might give new insight for the treatment of acute MI. In this thesis, molecular and cellular cardiac MRI methods were established to visualize and investigate inflammation and calcium flux in the healing process of acute MI in vivo, in a clinically relevant rat model.
MRT und CT liefern komplementäre Informationen über die Strukturen der Cochlea. Um die genaue Lage der Elektrode nach Implantation eines CIs beurteilen zu können, wurden in der vorliegenden Arbeit präoperative MRT-Datensätze und postoperative CT-Datensätze mit dem frei erhältlichen Programm "3D-Slicer" fusioniert. Nach 1350 erfolgten Implantationen am Universitätsklinikum Würzburg konnte bei 16 Ohren die Qualität der Fusion beurteilt und bei 15 Ohren die intracochleäre Lage der CI-Elektroden evaluiert werden. Die manuelle Fusion der Datensätze wurde in einer reproduzierbaren Vorgehensweise umgesetzt und war der automatischen Registrierung überlegen. Bildfusion und -analyse ließen sich umso präziser und sicherer durchführen, je besser die Bildqualität und je kürzer der zeitliche Abstand zwischen der Akquisition von MRT und CT waren. Da die Cochlea bei Geburt bereits ausgewachsen ist, war die Fusion selbst bei den Kindern möglich, deren Schädel in der Zwischenzeit gewachsen war. Aufgrund der seltenen Indikation eines postoperativen CTs und mangelnder Standardisierung der Bildgebung konnte eine Analyse lediglich bei 15 der insgesamt 1350 Ohren mit CI durchgeführt werden. In diesen Fällen ließ sich die Fusion jedoch sehr gut durchführen. Die Sicherheit bei der Beurteilung der Elektrodenlage nimmt in den einzelnen Abschnitten der Cochlea von basal nach apikal ab. Unabhängig davon waren die Entscheidungen für die Elektrodenlage in der Scala tympani mit einer größeren Sicherheit gefällt worden als die für die Lage in der Scala vestibuli. Die genaue Elektrodenlage konnte im Rahmen dieser Studie zwar nicht anhand histologischer Schnitte bewiesen werden, jedoch stimmen die in den fusionierten Bildern analysierten Insertionsstellen mit den in den OP-Berichten dokumentierten Angaben überein.
Die Myokardausdehnung wird als neuer Parameter der Infarktanatomie eingeführt. Dessen Entwicklung über die Zeit korreliert in hohem Maße mit der Entwicklung des enddiastolischen Volumens. Beide gemeinsam, die Myokardausdehnung und die Infarktausdehnung, bestimmen die Entwicklung des enddiastolischen Volumens im Laufe des linksventrikulären Remodellings nach Myokardinfarkt. Neben den bekannten verschiedenen Formen der Dilatation des linken Ventrikels kommt es bei zahlreichen Patienten auch zu einem Rückgang des enddiastolischen Volumens im Verlauf des Remodellings.
Intrazerebrale stereotaktische Eingriffe werden zu einem großen Teil ohne direkte Sichtkontrolle durchgeführt. Ein Operateur muss sich deshalb bei der räumlichen Festlegung von Strukturen und beim Anfahren dieser Strukturen auf Hilfsmittel wie stereotaktische Geräte und auf Atlanten, über welche die stereotaktischen Geräte gesteuert werden, verlassen. Trotz großer Fortschritte bei den bildgebenden Verfahren während der letzten dreißig Jahre, ist es gegenwärtig noch nicht möglich, zuverlässig alle subkortikalen Strukturen mit computertomographischen (CT) oder magnetresonanztomographischen (MRT) zu identifizieren oder begrenzen. Eine ganze Reihe zytoarchitektonischer beziehungsweise immunhistochemischer Atlanten wurde veröffentlicht. Dennoch ist es nicht gelungen, die Ergebnisse und Abbildungen dieser Atlanten mit bildgebenden Verfahren bis in die gewünschten Details zu kombinieren, um auf diese Weise das immer noch geringe Auflösungsvermögen radiologischer Methoden zu erhöhen. Deformationen bei der Gewebsentnahme des Gehirns, bei der anschließenden Einbettung, bei der alkoholischen Dehydrierung des Gewebes, Verformungen beim Schneiden und Färben der Schnitte überfordern selbst hoch komplexe mathematische Verfahren und Algorithmen beim Versuch, zytoarchitektonische und immunhistochemische Schnitte mit der gewünschten Präzision den radiologischen Ergebnissen und Bildern und damit indirekt auch den Verhältnissen in vivo anzupassen. Als Alternative verwendeten wir ungewöhnlich dicke (350 – 440 µm) Gallozyanin- (Nissl) gefärbte Serienschnitte durch die Gehirne (ZNS) von drei Personen im Alter von 56, 68 und 36 Jahren. Bei einem Fall wurde das ZNS post mortem mit einem Kernspintomographen vor der Entnahme gescannt. Die Serienschnitte durch dieses Gehirn und das eines zweiten und dritten nicht-gescannten Falles wurden mit Gallozyanin gefärbt, die zytoarchitektonischen Grenzen des Thalamuskomplexes und seiner Unterkerne wurden nach Hassler (1982) identifiziert, jede ihrer Grenzen mit dem Cursor eines Graphiktabletts umfahren und die Gestalt des Thalamuskomplexes und seiner Unterkerne mit Hilfe von Photoshop CS5® und eines computergestützten 3D-Rekonstruktionsprogramms (Amira®) dargestellt. Im Fall 3 ließen sich nach Dunkelfeldbeleuchten die Verteilung markhaltiger Fasern studieren und die zytoarchitektonischen mit myeloarchitektonischen Befunden erweitern und ergänzen. Zusätzlich konnten im Fall 1 die histologischen Serienschnitte und ihre 3D Rekonstruktion mit dem post mortem in cranio MRT registriert werden. Insgesamt kann dieser methodische Ansatz als eine robuste und relativ einfache wenn auch mit umfangreicherer manueller Tätigkeit verbundene Technik zur sehr detailreichen unverformten Korrelation zytoarchitektonischer und kernspinotomographsicher Darstellung des Thalamuskomplexus und seiner Unterkerne angesehen werden. Sie könnte als Grundlage für die Herausgabe eines multimedialen 3D stereotaktischen Atlas des menschlichen Gehirns dienen.
Das Ziel dieser Promotion ist der Aufbau eines dreMR Setups für einen klinischen 1,5T Scanner, das die Relaxations-Dispersions-Bildgebung ermöglicht, und die anschließende Ergründung von möglichst vielen Anwendungsfeldern von dreMR. Zu der Aufgabe gehört die Bereitstellung der zugrunde liegenden Theorie, der Bau des experimentellen Setups (Offset-Spule und Stromversorgung) sowie die Programmierung der nötigen Software. Mit dem gebauten Setup konnten zwei große Anwendungsfelder — dreMR Messungen mit und ohne Kontrastmitteln — untersucht werden.
Synthese von Dextran-umhüllten Eisenoxid-Nanopartikeln als Kontrastmittel für die MR-Tomographie
(2012)
Durch Fällung von Eisen(II)- und Eisen(III)-salzen wurden Dextran-umhüllte Eisenoxid-Nanopartikel (SPIOs) und durch anschließende Umsetzung mit Epichlorhydrin und Ammoniak CLIOs gewonnen. An diesen Kolloiden wurden niedermolekulare Moleküle wie Diamine oder Bernsteinsäureanhydrid als Linker angebracht. Ein weiterer Aspekt dieser Arbeit stellt die Anbindung von Fluoreszenzmarkern und Antikörpern an der Partikeloberfläche sowie deren spektroskopische Untersuchung dar.
In dieser Arbeit wurden für spezielle Anwendungen an klinischen MR-Geräten optimierte Phased-Array-Spulen entwickelt. Das Ziel war, durch die Verwendung neuer Spulen entweder neue Anwendungsgebiete für klinische MR-Geräte zu eröffnen oder bei bestehenden Applikationen die Diagnosemöglichkeiten durch eine Kombination von höherem SNR und kleineren g-Faktoren im Vergleich zu bestehenden Spulen zu verbessern. In Kapitel 3 wurde untersucht, ob es durch den Einsatz neu entwickelter, dedizierter Kleintierspulen sinnvoll möglich ist, Untersuchungen an Kleintieren an klinischen MR-Geräten mit einer Feldstärke von 1,5T durchzuführen. Der Einsatz dieser Spulen verspricht dem klinischen Anwender Studien an Kleintieren durchführen zu können, bei denen er den gleichen Kontrast wie bei einer humanen Anwendung erhält und gleichzeitig Kontrastmittel sowie Sequenzen, die klinisch erprobt sind, einzusetzen. Durch die gewählten geometrischen Abmessungen der Spulen ist es möglich, Zubehör von dedizierten Tier-MR-Geräten, wie z. B. Tierliegen oder EKG- bzw. Atemtriggereinheiten, zu verwenden. Durch Vorversuche an für Ratten dimensionierten Spulen wurden grundlegende Zusammenhänge zwischen verwendetem Entkopplungsmechanismus und SNR bzw. Beschleunigungsfähigkeit erarbeitet. Für Ratten wurde gezeigt, dass in akzeptablen Messzeiten von unter fünf Minuten MR-Messungen des Abdomens in sehr guter Bildqualität möglich sind. Ebenfalls gezeigt wurde die Möglichkeit durch den Einsatz von paralleler Bildgebung sowie Kontrastmitteln hochaufgelöste Angiographien durchzuführen. Es stellte sich heraus, dass bei 1,5T dedizierte Mäusespulen bei Raumtemperatur von den SNR-Eigenschaften am Limit des sinnvoll Machbaren sind. Trotzdem war es möglich, auch für Mäuse ein 4-Kanal-Phased-Array zu entwickeln und den Einsatz bei kontrastmittelunterstützten Applikationen zu demonstrieren. Insgesamt wurde gezeigt, dass durch den Einsatz von speziellen, angepassten Kleintierspulen auch Tieruntersuchungen an klinischen MR-Geräten mit niedriger Feldstärke durchführbar sind. Obwohl sich die Bestimmung der Herzfunktion an MR-Geräten im klinischen Alltag zum Goldstandard entwickelt hat, ist die MR-Messung durch lange Atemanhaltezyklen für einen Herzpatienten sehr mühsam. In Kapitel 4 wurde deswegen die Entwicklung einer 32-Kanal-Herzspule beschrieben, welche den Komfort für Patienten deutlich erhöhen kann. Schon mit einem ersten Prototypen für 3T war es möglich, erstmals Echtzeitbildgebung mit leicht reduzierter zeitlicher Auflösung durchzuführen und damit auf das Atemanhalten komplett zu verzichten. Dies ermöglicht den Zugang neuer Patientengruppen, z. B. mit Arrythmien, zu MR-Untersuchungen. Durch eine weitere Optimierung des Designs wurde das SNR sowie das Beschleunigungsvermögen signifikant gesteigert. Bei einem Beschleunigungsfaktor R = 5 in einer Richtung erhält man z. B. gemittelt über das gesamte Herz ein ca. 60 % gesteigertes SNR zu dem Prototypen. Die Kombination dieser Spule zusammen mit neuentwicklelten Methoden wie z. B. Compressed- Sensing stellt es in Aussicht, die Herzfunktion zukünftig in der klinischen Routine in Echtzeit quantifizieren zu können. In Kapitel 5 wurde die Entwicklung einer optimierten Brustspulen für 3T beschrieben. Bei Vorversuchen bei 1,5T wurden Vergleiche zwischen der Standardspule der Firma Siemens Healthcare und einem 16-Kanal-Prototypen durchgeführt. Trotz größerem Spulenvolumen zeigt die Neuentwicklung sowohl hinsichtlich SNR als auch paralleler Bildgebungseigenschaften eine signifikante Verbesserung gegenüber der Standardspule. Durch die Einhaltung aller Kriterien für Medizinprodukte kann diese Spule auch für den klinischen Einsatz verwendet werden. Mit den verbesserten Eigenschaften ist es beispielsweise möglich, bei gleicher Messdauer eine höhere Auflösung zu erreichen. Aufgrund des intrinsischen SNR-Vorteils der 3 T-Spule gegenüber der 1,5 T-Spule ist es dort sogar möglich, bei höheren Beschleunigungsfaktoren klinisch verwertbare Schnittbilder zu erzeugen. Zusammenfassend wurden für alle drei Applikationen NMR-Empfangsspulen entwickelt, die im Vergleich zu den bisher verfügbaren Spulen, hinsichtlich SNR und Beschleunigungsvermögen optimiert sind und dem Anwender neue Möglichkeiten bieten.
This thesis focuses on various aspects and techniques of 19F magnetic resonance (MR). The first chapters provide an overview of the basic physical properties, 19F MR and MR sequences related to this work. Chapter 5 focuses on the application of 19F MR to visualize biological processes in vivo using two different animal models. The dissimilar models underlined the wide applicability of 19F MR in preclinical research. A subsection of Chapter 6 shows the application of compressed sensing (CS) to 19F turbo-spin-echo chemical shift imaging (TSE-CSI), which leads to reduced measurement time. CS, however, can only be successfully applied when a sufficient signal-to-noise ratio (SNR) is available. When the SNR is low, so-called spike artifacts occur with the CS algorithm used in the present work. However, it was shown in an additional subsection that these artifacts can be reduced using a CS-based post processing algorithm. Thus, CS might help overcome limitations with time consuming 19F CSI experiments. Chapter 7 deals with a novel technique to quantify the B+1 profile of an MR coil. It was shown that, using a specific application scheme of off resonant pulses, Bloch-Siegert (BS)-based B+1 mapping can be enabled using a Carr Purcell Meiboom Gill (CPMG)-based TSE sequence. A fast acquisition of the data necessary for B+1 mapping was thus enabled. In the future, the application of BS-CPMG-TSE B+1 mapping to improve quantification using 19F MR could therefore be possible.