Refine
Has Fulltext
- yes (3)
Is part of the Bibliography
- yes (3)
Year of publication
- 2022 (3) (remove)
Document Type
- Doctoral Thesis (3)
Keywords
- 3D-Druck (3) (remove)
In this thesis, non-modified POx, namely PnPrOx and PcycloPrOx, with an LCST in the physiological range between 20 and 37°C have been utilized as materials for three different biofabrication approaches. Their thermoresponsive behavior and processability were exploited to establish an easy-to-apply coating for cell sheet engineering, a novel method to create biomimetic scaffolds based on aligned fibrils via Melt Electrowriting (MEW) and the application of melt electrowritten sacrificial scaffolds for microchannel creation for hydrogels.
Chapter 3 describes the establishment of a thermoresponsive coating for tissue culture plates. Here, PnPrOx was simply dissolved in water and dried in well plates and petri dishes in an oven. PnPrOx adsorbed to the surface, and the addition of warm media generated a cell culture compatible coating. It was shown that different cell types were able to attach and proliferate. After confluency, temperature reduction led to the detachment of cell sheets. Compared to standard procedures for surface coating, the thermoresponsive polymer is not bound covalently to the surface and therefore does not require specialized equipment and chemical knowledge. However, it should be noted that the detachment of the cell layer requires the dissolution of the PnPrOx-coating, leading to possible polymer contamination. Although it is only a small amount of polymer dissolved in the media, the detached cell sheets need to be washed by media exchange for further processing if required. ...
Articular cartilage is a highly specialized tissue which provides a lubricated gliding surface in joints and thereby enables low-friction movement. If damaged once it has a very low intrinsic healing capacity and there is still no treatment in the clinic which can restore healthy cartilage tissue. 3D biofabrication presents a promising perspective in the field by combining healthy cells and bioactive ink materials. Thereby, the composition of the applied bioink is crucial for defect restoration, as it needs to have the physical properties for the fabrication process and also suitable chemical cues to provide a supportive environment for embedded cells. In the last years, ink compositions with high polymer contents and crosslink densities were frequently used to provide 3D printability and construct stability. But these dense polymeric networks were often associated with restricted bioactivity and impaired cell processes like differentiation and the distribution of newly produced extracellular matrix (ECM), which is especially important in the field of cartilage engineering. Therefore, the aim of this thesis was the development of hyaluronic acid (HA)-based bioinks with a reduced polymer content which are 3D printable and additionally facilitate chondrogenic differentiation of mesenchymal stromal cells (MSCs) and the homogeneous distribution of newly produced ECM. Starting from not-printable hydrogels with high polymer contents and restricted bioactivity, distinct stepwise improvements were achieved regarding stand-alone 3D printability as well as MSC differentiation and homogeneous ECM distribution. All newly developed inks in this thesis made a valuable contribution in the field of cartilage regeneration and represent promising approaches for potential clinical applications. The underlying mechanisms and established ink design criteria can further be applied to other biofabricated tissues, emphasizing their importance also in a more general research setting.
Simulation der Kariesentfernung an 3D-gedruckten Molaren: Analyse der Reliabilität und der Validität
(2022)
In der vorliegenden Studie wurde an 50 3D-gedruckten Molaren mit einer konstruierten Referenzkaries das Ausmaß der vollständigen Kariesentfernung flächenabhängig überprüft. Die untersuchten Zähne wurden mit einer simulierten, standardisierten und mehrflächigen Karies versehen. Studierende der Zahnmedizin haben die Karies entfernt, die Kavität mit einer Aufbaufüllung versorgt und die Zähne für eine Vollkrone präpariert. Um die Kariesentfernung zu bewerten, wurden DVT-Aufnahmen und dreidimensionale Scans angefertigt. Aus den DVT-Datensätzen im DICOM-Format wurden die Aufbaufüllungen der Zähne mithilfe digitaler Bildverarbeitung segmentiert und als eigenständige 3D-Modelle dargestellt. Anschließend erfolgte die Überlagerung der Aufbaufüllungen auf den Referenzzahn aus der Konstruktionsdatei der Zähne. Mit der Konstruktionssoftware Autodesk Fusion 360 wurden die Aufbaufüllungen in Volumenkörper umgewandelt und mit der Karies des Referenzzahnes verglichen. Da sich die Aufbaufüllungen mit der Referenzkaries überschneiden, konnte die Software mit ihrer Teilungsfunktion nicht überschneidende Teile separieren. Abhängig von der Lage der Kavität, in der sich die überschüssigen Volumenkörper befanden, wurden jene als Restkaries oder überexkavierte Zahnhartsubstanz identifiziert. Die gemessenen Volumina von Restkaries ergaben, dass an der distalen Zahnfläche im Vergleich zur bukkalen und okklusalen signifikant mehr Karies verblieben war. Ein weiterer signifikanter Unterschied konnte zwischen mesial und bukkal, jedoch nicht zwischen mesial und okklusal festgestellt werden. Bei der Überexkavation gab es zwischen den Zahnflächen keine Unterschiede. Die Ergebnisse zeigten, dass die Kariesentfernung an den approximalen Zahnflächen für die Studierenden eine höhere manuelle Herausforderung darstellte. Neben der volumetrischen Vermessung ermöglichte die dreidimensionale Visualisierung von Restkaries und der überexkavierten Zahnhartsubstanz eine objektive Bewertung des Behandlungsergebnisses für die Studierenden und deren Ausbilder. Besonders der Vergleich mit einer Referenz schaffte eine valide und nachvollziehbare Beurteilung der Kariesübung an 3D-gedruckten Zähnen.