Refine
Has Fulltext
- yes (14) (remove)
Is part of the Bibliography
- yes (14)
Year of publication
Document Type
- Journal article (9)
- Doctoral Thesis (5)
Keywords
- hemodialysis (14) (remove)
Institute
- Medizinische Klinik und Poliklinik I (14) (remove)
Background
Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting.
Methods
Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary.
Results
120 patients were screened, 109 enrolled (median age 71; range 26–90 years) and 106 available for efficacy analyses. The percentage of unsatisfactory dialysis results at 8 weeks due to clotting or bleeding, was 1.9% (n = 2/106; 95% confidence interval [CI] 0.23–6.65%); no major bleeding. 1.9% had moderate/severe clotting in the lines/bubble catcher and 2.8% in the dialyser at week 8. 15.7 ± 14.3% of the dialysis filters’ visual surface area was showing redness. In subgroups of patients receiving median doses of 3000 ± 0, 3000 (2400–6000) and 4200 (3000–6600) IU, plasma aXa levels at baseline, 4 and 8 weeks were 0.24 [95%CI 0.21–0.27], 0.33 [0.27–0.40] and 0.38 [0.33–0.45] aXa IU/ml at 2 h. \(C_{48h}\) was 0.01 [0.01–0.02] aXa IU at all visits. At baseline and 4 weeks \(AUC_{0-48h}\) was 2.66 [2.19–3.24] and 3.66 [3.00–4.45] aXa IU*h/ml. In 3.0% of dialyses (n = 83/2724) prolonged fistula compression times were documented. Eight patients (7.34%) had at least one episode of minor bleeding. 4) 85.3% of patients had any adverse event, 9.2% were serious without suspected drug relation; and in 32 patients a drug-relation was suspected.
Conclusions
Certoparin appears effective and safe for anticoagulation in patients undergoing maintenance hemodialysis.
Protein binding prevents uremic toxins from removal by conventional extracorporeal therapies leading to accumulation in maintenance dialysis patients. Weakening of the protein binding may enhance the dialytic elimination of these toxins. In ultrafiltration and equilibrium dialysis experiments, different measures to modify the plasma binding affinity and capacity were tested: (i), increasing the sodium chloride (NaCl) concentration to achieve a higher ionic strength; (ii), increasing the temperature; and (iii), dilution. The effects on the dissociation constant K-D and the protein bound fraction of the prototypical uremic toxin indoxyl sulfate (IS) in plasma of healthy and uremic individuals were studied. Binding of IS corresponded to one site binding in normal plasma. K-D increased linearly with the NaCl concentration between 0.15 (K-D = 13.2 +/- 3.7 mu M) and 0.75 M (K-D = 56.2 +/- 2.0 mu M). Plasma dilution further reduced the protein bound toxin fraction by lowering the protein binding capacity of the plasma. Higher temperatures also decreased the protein bound fraction of IS in human plasma. Increasing the NaCl concentration was effective to weaken the binding of IS also in uremic plasma: the protein bound fraction decreased from 89% +/- 3% to 81% +/- 3% at 0.15 and 0.75 M NaCl, respectively. Dilution and increasing the ionic strength and temperature enhance the free fraction of IS allowing better removal of the substance during dialysis. Applied during clinical dialysis, this may have beneficial effects on the long-term outcome of maintenance dialysis patients.
Introduction
Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis.
Methods
In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified.
Results
ELISIO-HX achieved slightly lower reduction ratios for β2-microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2%/g; p = 0.006) to ELISIO-HX.
Conclusions
The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis.
Introduction Patients with end-stage kidney disease requiring maintenance haemodialysis treatment experience a dramatic cardiovascular morbidity and mortality. Due to the high atherosclerotic and arteriosclerotic burden and profound alterations in haemostasis, they frequently suffer and die from both thromboembolic and bleeding events. This is a particular concern in patients on haemodialysis with atrial fibrillation (AF). Controlled trials on the optimal anticoagulation in patients with AF on haemodialysis are not available. The randomised controlled phase IIIb AXADIA-AFNET 8 trial will evaluate the safety and efficacy of the factor Xa inhibitor apixaban in patients with AF requiring haemodialysis. Methods and analysis A total of 222 patients will be randomised in an open-labelled, 1:1 design to receive either apixaban 2.5mg twice daily or dose-adjusted vitamin K antagonist therapy (target international normalised ratio 2.0-3.0). All patients will be treated and followed up for a minimum of 6 months up to a maximum of 24 months. The primary outcome is major or clinically relevant, non-major bleedings or death of any cause. Secondary outcomes include stroke, cardiovascular death and other thromboembolic events, thus exploring the efficacy of apixaban. The first patient was randomised in June 2017. Ethics and dissemination The study protocol was approved by the Ethical Committee of the Landesaertzekammer, Westfalen-Lippe and the Medical Faculty of the University of Muenster, Muenster, Germany (reference number: 2016-598f-A). Written informed consent will be obtained from all patients prior to study participation, including their consent for long-term follow-up. AXADIA-AFNET 8 is an investigator-initiated trial. Sponsor is AFNET, Muenster, Germany. Study findings will be disseminated to Bristol-Myers Squibb, Munich, Germany, and Pfizer, Berlin, Germany, to the participating centres, at research conferences and in peer-reviewed journals. Trial registration numbers NCT02933697, Pre-results.
The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied. The present prospective, randomized, cross-over trial tested dialysis efficacy and monitored pre-treatment pCS and IS concentrations in 15 patients on low-flux and high-flux hemodialysis and high-convective volume postdilution hemodiafiltration over six weeks each. Although hemodiafiltration achieved by far the highest toxin removal, only the mean total IS level was decreased at week three (16.6 ± 12.1 mg/L) compared to baseline (18.9 ± 13.0 mg/L, p = 0.027) and to low-flux dialysis (20.0 ± 12.7 mg/L, p = 0.021). At week six, the total IS concentration in hemodiafiltration reached the initial values again. Concentrations of free IS and free and total pCS remained unaltered. Highest beta2-microglobulin elimination in hemodiafiltration (p < 0.001) led to a persistent decrease of the plasma levels at week three and six (each p < 0.001). In contrast, absent removal in low-flux dialysis resulted in rising beta2-microglobulin concentrations (p < 0.001). In conclusion, this trial demonstrated that even large differences in instantaneous protein-bound toxin removal by current extracorporeal dialysis techniques may have only limited impact on IS and pCS plasma levels in the longer term.
Background
In patients undergoing maintenance hemodialysis (HD), increased levels of circulating fibroblast growth factor-23 (FGF-23) are independently associated with cardiovascular events and mortality. Interventional strategies aiming to reduce levels of FGF-23 in HD patients are of particular interest. The purpose of the current study was to compare the impact of high-flux versus low-flux HD on circulating FGF-23 levels.
Methods
We conducted a post-hoc analysis of the MINOXIS study, including 127 dialysis patients randomized to low-flux (n = 62) and high-flux (n = 65) HD for 52 weeks. Patients with valid measures for FGF-23 investigated baseline and after 52 weeks were included.
Results
Compared to baseline, a significant increase in FGF-23 levels after one year of low-flux HD was observed (Delta plasma FGF-23: +4026 RU/ml; p < 0.001). In contrast, FGF-23 levels remained stable in the high flux group (Delta plasma FGF-23: +373 RU/ml, p = 0.70). The adjusted difference of the absolute change in FGF-23 levels between the two treatment groups was statistically significant (p < 0.01).
Conclusions
Over a period of 12 months, high-flux HD was associated with stable FGF-23 levels, whereas the low-flux HD group showed an increase of FGF-23. However, the implications of the different FGF 23 time-trends in patients on high flux dialysis, as compared to the control group, remain to be explored in specifically designed clinical trials.
In dieser post-hoc Analyse der Deutschen Diabetes und Dialyse Studie wurde der Einfluss von NT-proBNP und Troponin T auf plötzlichen Herztod, Schlaganfall, Myokardinfarkt und die Gesamtmortalität während vierjähriger Studiendauer bei 1255 Patienten mit Diabetes mellitus Typ 2 an der Hämodialyse analysiert. Des Weiteren wurde die Bedeutung einer longitudinalen Messung der Biomarker nach 6 Monaten auf die Endpunkte untersucht. Patienten mit dem höchsten NT-proBNP respektive Troponin T wiesen die größte Ereignisrate für plötzlichen Herztod, Schlaganfall und die Gesamtmortalität auf. In der multivariaten Regressionsanalyse waren sowohl NT-proBNP als auch Troponin T jeweils starke unabhängige Prädiktoren für plötzlichen Herztod, Schlaganfall und die Gesamtmortalität. Eine Assoziation von NT-proBNP mit dem Auftreten von Myokardinfarkten wurde nicht gesehen. Nicht nur ein hoher Ausgangswert der Biomarker, sondern auch eine Zunahme von NT-proBNP und Troponin T nach 6 Monaten waren assoziiert mit einer schlechteren Langzeitprognose
Zirkulierende endotheliale Vorläuferzellen, kurz EPCs, werden als Biomarker für kardiovaskuläre Erkrankungen genutzt. In einer prospektiven, randomisierten Cross-over-Studie wurden 18 chronische Dialysepatienten während jeweils vier Wochen mit Low-Flux-HD, High-Flux-HD sowie Hämodiafilatration behandelt. EPCs wurden zu Beginn sowie am Ende jedes Intervalls bestimmt. Trotz deutlicher Unterschiede bezüglich der Toxinentfernung im mittelmolekularen Bereich zeigte sich kein Einfluss auf Qualität und Quantität der EPCs
A large number of metabolic waste products accumulate in the blood of patients with renal failure. Since these solutes have deleterious effects on the biological functions, they are called uremic toxins and have been classified in three groups: 1) small water soluble solutes (MW < 500 Da), 2) small solutes with known protein binding (MW < 500 Da), and 3) middle molecules (500 Da < MW < 60 kDa). Protein bound uremic toxins are poorly removed by conventional hemodialysis treatments because of their high protein binding and high distribution volume. The prototypical protein bound uremic toxins indoxyl sulfate (IS) and p-cresyl sulfate (pCS) are associated with the progression of chronic kidney disease, cardiovascular outcomes, and mortality of patients on maintenance hemodialysis. Furthermore, these two compounds are bound to albumin, the main plasma protein, via electrostatic and/or Van-der-Waals forces. The aim of the present thesis was to develop a dialysis strategy, based on the reversible modification of the ionic strength in the blood stream by increasing the sodium chloride (NaCl) concentration, in order to enhance the removal of protein bound substances, such as IS and pCS, with the ultimate goal to improve clinical patient outcomes. Enhancing the NaCl concentration ([NaCl]) in both human normal and uremic plasma was efficient to reduce the protein bound fraction of both IS and pCS by reducing their binding affinity to albumin. Increasing the ionic strength was feasible during modified pre-dilution hemodiafiltration (HDF) by increasing the [NaCl] in the substitution fluid. The NaCl excess was adequately removed within the hemodialyzer. This method was effective to increase the removal rate of both protein bound uremic toxins. Its ex vivo hemocompatibility, however, was limited by the osmotic shock induced by the high [NaCl] in the substituate. Therefore, modified pre-dilution HDF was further iterated by introducing a second serial cartridge, named the serial dialyzers (SDial) setup. This setting was validated for feasibility, hemocompatibility, and toxin removal efficiency. A better hemocompatibility at similar efficacy was obtained with the SDial setup compared with the modified pre-dilution HDF. Both methods were finally tested in an animal sheep model of dialysis to verify biocompatibility. Low hemolysis and no activation of both the complement and the coagulation systems were observed when increasing the [NaCl] in blood up to 0.45 and 0.60 M with the modified pre-dilution HDF and the SDial setup, respectively. In conclusion, the two dialysis methods developed to transitory enhance the ionic strength in blood demonstrated adequate biocompatibility and improved the removal of protein bound uremic toxins by decreasing their protein bound fraction. The concepts require follow-on clinical trials to assess their in vivo efficacy and their impact on long-term clinical outcomes.
In der vorliegenden Arbeit wird der Einfluss von hs-CRP und Albumin auf die kardiovaskuläre Ereignisrate und das Überleben von Patienten mit Diabetes Mellitus Typ 2 an der Hämodialyse untersucht. Grundlagen für die hier dargestellte Auswertung sind die in der 4D Studie erhobenen Daten. Die 4D Studie hat prospektiv, randomisiert, doppelblind und placebo-kontrolliert untersucht, ob die Behandlung mit Atorvastatin bei Patienten mit Diabetes Mellitus Typ 2 an der Hämodialyse den primären Endpunkt bestehend aus Herzinfarkt, kardialem Tod und Schlaganfall zu senken vermag. Die Daten zum hs-CRP und Albumin wurden bei Studienbeginn und nach sechs Monaten erhoben. In einer post-hoc Analyse mit Hilfe eines multivariaten Cox Regressionsmodels konnte bestätigt werden, dass ein erhöhter Spiegel an hs-CRP und ein verminderter Spiegel an Albumin im Zusammenhang mit einer vermehrten kardiovaskulären Ereignisrate und Mortalität stehen. Eine Behandlung mit Atorvastatin führte zwar nicht zu einer Risikosenkung für den primären Endpunkt oder die Mortalität, hatte aber einen stabilisierenden Effekt auf des hs-CRP Spiegel.