Refine
Has Fulltext
- yes (34)
Is part of the Bibliography
- yes (34)
Year of publication
Document Type
- Journal article (26)
- Conference Proceeding (4)
- Preprint (3)
- Doctoral Thesis (1)
Language
- English (34) (remove)
Keywords
- PET (34) (remove)
Institute
- Klinik und Poliklinik für Nuklearmedizin (30)
- Medizinische Klinik und Poliklinik I (7)
- Medizinische Klinik und Poliklinik II (6)
- Institut für Anatomie und Zellbiologie (2)
- Institut für Pharmakologie und Toxikologie (2)
- Neurologische Klinik und Poliklinik (2)
- Pathologisches Institut (2)
- Comprehensive Cancer Center Mainfranken (1)
- Graduate School of Life Sciences (1)
- Institut für Experimentelle Biomedizin (1)
- Institut für Pharmazie und Lebensmittelchemie (1)
- Institut für Theoretische Physik und Astrophysik (1)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen (1)
- Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
Sonstige beteiligte Institutionen
- Johns Hopkins School of Medicine (8)
- Johns Hopkins School of Medicine, Baltimore, MD, U.S. (2)
- Johns Hopkins University School of Medicine (2)
- Hospital Augsburg, Augsburg, Germany (1)
- Johns Hopkins University School of Medicine, Baltimore, MD, U.S. (1)
- Johns Hopkins University, Baltimore, MD, U.S. (1)
- Johns Hopkis School of Medicine (1)
Aim
Recent advancements in PET technology have brought with it significant improvements in PET performance and image quality. In particular, the extension of the axial field of view of PET systems, and the introduction of semiconductor technology into the PET detector, initially for PET/MR, and more recently available long-field-of-view PET/CT systems (≥ 25 cm) have brought a step change improvement in the sensitivity of PET scanners. Given the requirement to limit paediatric doses, this increase in sensitivity is extremely welcome for the imaging of children and young people. This is even more relevant with PET/MR, where the lack of CT exposures brings further dose reduction benefits to this population. In this short article, we give some details around the benefits around new PET technology including PET/MR and its implications on the EANM paediatric dosage card.
Material and methods
Reflecting on EANM adult guidance on injected activities, and making reference to bed overlap and the concept of MBq.min bed\(^{-1}\) kg\(^{-1}\), we use published data on image quality from PET/MR systems to update the paediatric dosage card for PET/MR and extended axial field of view (≥ 25 cm) PET/CT systems. However, this communication does not cover the expansion of paediatric dosing for the half-body and total-body scanners that have recently come to market.
Results
In analogy to the existing EANM dosage card, new parameters for the EANM paediatric dosage card were developed (class B, baseline value: 10.7 MBq, minimum recommended activity 10 MBq). The recommended administered activities for the systems considered in this communication range from 11 MBq [\(^{18}\)F]FDG for a child with a weight of 3 kg to 149 MBq [\(^{18}\)F]FDG for a paediatric patient weight of 68 kg, assuming a scan of 3 min per bed position. The mean effective dose over all ages (1 year and older) is 2.85 mSv.
Conclusion
With this, recommendations for paediatric dosing are given for systems that have not been considered previously.
Serotonin (5-hydroxytryptamine, 5-HT) as well as noradrenaline (NA) are key modulators of various fundamental brain functions including the control of appetite. While manipulations that alter brain serotoninergic signaling clearly affect body weight, studies implicating 5-HT transporters and NA transporters (5-HTT and NAT, respectively) as a main drug treatment target for human obesity have not been conclusive. The aim of this positron emission tomography (PET) study was to investigate how these central transporters are associated with changes of body weight after 6 months of dietary intervention or Roux-en-Y gastric bypass (RYGB) surgery in order to assess whether 5-HTT as well as NAT availability can predict weight loss and consequently treatment success. The study population consisted of two study cohorts using either the 5-HTT-selective radiotracer [\(^{11}\)C]DASB to measure 5-HTT availability or the NAT-selective radiotracer [\(^{11}\)C]MRB to assess NAT availability. Each group included non-obesity healthy participants, patients with severe obesity (body mass index, BMI, >35 kg/m\(^2\)) following a conservative dietary program (diet) and patients undergoing RYGB surgery within a 6-month follow-up. Overall, changes in BMI were not associated with changes of both 5-HTT and NAT availability, while 5-HTT availability in the dorsal raphe nucleus (DRN) prior to intervention was associated with substantial BMI reduction after RYGB surgery and inversely related with modest BMI reduction after diet. Taken together, the data of our study indicate that 5-HTT and NAT are involved in the pathomechanism of obesity and have the potential to serve as predictors of treatment outcomes.
Background
CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs.
Methods
Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden.
Results
Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found.
Conclusions
In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged.
Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7% radiochemical yield and at a >99% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6–4.4% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.