Plasma membrane receptors are the most crucial and most commonly studied components of cells, since they not only ensure communication between the extracellular space and cells, but are also responsible for the regulation of cell cycle and cell division. The composition of the surface receptors, the so-called "Receptome", differs and is characteristic for certain cell types. Due to their significance, receptors have been important target structures for diagnostic and therapy in cancer medicine and often show aberrant expression patterns in various cancers compared to healthy cells. However, these aberrations can also be exploited and targeted by different medical approaches, as in the case of personalized immunotherapy. In addition, advances in modern fluorescence microscopy by so-called single molecule techniques allow for unprecedented sensitive visualization and quantification of molecules with an attainable spatial resolution of 10-20 nm, allowing for the detection of both stoichiometric and expression density differences.
In this work, the single molecule sensitive method dSTORM was applied to quantify the receptor composition of various cell lines as well as in primary samples obtained from patients with hematologic malignancies. The focus of this work lies on artefact free quantification, stoichiometric analyses of oligomerization states and co localization analyses of membrane receptors.
Basic requirements for the quantification of receptors are dyes with good photoswitching properties and labels that specifically mark the target structure without generating background through non-specific binding. To ensure this, antibodies with a predefined DOL (degree of labeling) were used, which are also standard in flow cytometry. First background reduction protocols were established on cell lines prior analyses in primary patient samples. Quantitative analyses showed clear expression differences between the cell lines and the patient cells, but also between individual patients.
An important component of this work is the ability to detect the oligomerization states of receptors, which enables a more accurate quantification of membrane receptor densities compared to standard flow cytometry. It also provides information about the activation of a certain receptor, for example of FLT3, a tyrosine kinase, dimerizing upon activation. For this purpose, different well-known monomers and dimers were compared to distinguish the typical localization statistics of single bound antibodies from two or more antibodies that are in proximity. Further experiments as well as co localization analyses proved that antibodies can bind to closely adjacent epitopes despite their size.
These analytical methods were subsequently applied for quantification and visualization of receptors in two clinically relevant examples. Firstly, various therapeutically relevant receptors such as CD38, BCMA and SLAMF7 for multiple myeloma, a malignant disease of plasma cells, were analyzed and quantified on patient cells. Furthermore, the influence of TP53 and KRAS mutations on receptor expression levels was investigated using the multiple myeloma cell lines OPM2 and AMO1, showing clear differences in certain receptor quantities.
Secondly, FLT3 which is a therapeutic target receptor for acute myeloid leukemia, was quantified and stoichiometrically analyzed on both cell lines and patient cells. In addition, cells that have developed resistance against midostaurin were compared with cells that still respond to this type I tyrosine-kinase-inhibitor for their FLT3 receptor expression and oligomerization state.
Fluorescence microscopy is a form of light microscopy that has developed during the 20th century and is nowadays a standard tool in Molecular and Cell biology for studying the structure and function of biological molecules. High-resolution fluorescence microscopy techniques, such as dSTORM (direct Stochastic Optical Reconstruction Microscopy) allow the visualization of cellular structures at the nanometre scale (10−9 m). This has already made it possible to decipher the composition and function of various biopolymers, such as proteins, lipids and nucleic acids, up to the three-dimensional (3D) structure of entire organelles. In practice, however, it has been shown that these imaging methods and their further developments still face great challenges in order to achieve an effective resolution below ∼ 10 nm. This is mainly due to the nature of labelling biomolecules. For the detection of molecular structures, immunostaining is often performed as a standard method. Antibodies to which fluorescent molecules are coupled, recognize and bind specifcally and with high affnity to the molecular section of the target structure, also called epitope or antigen. The fluorescent molecules serve as reporter molecules which are imaged with the use of a fluorescence microscope. However, the size of these labels with a length of about 10-15 nm in the case of immunoglobulin G (IgG) antibodies, cause a detection of the fluorescent molecules shifted to the real position of the studied antigen. In dense regions where epitopes are located close to each other, steric hindrance between antibodies can also occur and leads to an insuffcient label density. Together with the shifted detection of fluorescent molecules, these factors can limit the achievable resolution of a microscopy technique. Expansion microscopy (ExM) is a recently developed technique that achieves a resolution improvement by physical expansion of an investigated object. Therefore, biological samples such as cultured cells, tissue sections, whole organs or isolated organelles are chemically anchored into a swellable polymer. By absorbing water, this so-called superabsorber increases its own volume and pulls the covalently bound biomolecules isotropically apart. Routinely, this method achieves a magnifcation of the sample by about four times its volume. But protocol variants have already been developed that result in higher expansion factors of up to 50-fold. Since the ExM technique includes in the frst instance only the sample treatment for anchoring and magnifcation of the sample, it can be combined with various standard methods of fluorescence microscopy. In theory, the resolution of the used imaging technique improves linearly with the expansion factor of the ExM treated sample. However, an insuffcient label density and the size of the antibodies can here again impair the effective achievable resolution. The combination of ExM with high-resolution fluorescence microscopy methods represents a promising strategy to increase the resolution of light microscopy. In this thesis, I will present several ExM variants I developed which show the combination of ExM with confocal microscopy, SIM (Structured Illumination Microscopy), STED (STimulated Emission Depletion) and dSTORM. I optimized existing ExM protocols and developed different expansion strategies, which allow the combination with the respective imaging technique. Thereby, I gained new structural insights of isolated centrioles from the green algae Chlamydomonas reinhardtii by combining ExM with STED and confocal microscopy. In another project, I combined 3D-SIM imaging with ExM and investigated the molecular structure of the so-called synaptonemal complex. This structure is formed during meiosis in eukaryotic cells and contributes to the exchange of genetic material between homologous chromosomes. Especially in combination with dSTORM, the ExM method showed its high potential to overcome the limitations of modern fluorescence microscopy techniques. In this project, I expanded microtubules in mammalian cells, a polymer of the cytoskeleton as well as isolated centrioles from C. reinhardtii. By labelling after expansion of the samples, I was able to signifcantly reduce the linkage error of the label and achieve an improved label density. In future, these advantages together with the single molecule sensitivity and high resolution obtained by the dSTORM method could pave the way for achieving molecular resolution in fluorescence microscopy