Refine
Has Fulltext
- yes (20)
Is part of the Bibliography
- yes (20)
Document Type
- Journal article (20) (remove)
Language
- English (20) (remove)
Keywords
- 3D printing (20) (remove)
Institute
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (9)
- Frauenklinik und Poliklinik (4)
- Medizinische Klinik und Poliklinik II (2)
- Poliklinik für Zahnärztliche Prothetik (2)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (1)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (1)
- Klinik und Poliklinik für Nuklearmedizin (1)
- Lehrstuhl für Orthopädie (1)
- Physikalisches Institut (1)
- Poliklinik für Zahnerhaltung und Parodontologie (1)
EU-Project number / Contract (GA) number
- 617989 (1)
Additive manufacturing of scaffolds with sub-micron filaments via melt electrospinning writing
(2015)
The aim of this study was to explore the lower resolution limits of an electrohydrodynamic process combined with direct writing technology of polymer melts. Termed melt electrospinning writing, filaments are deposited layer-by-layer to produce discrete three-dimensional scaffolds for in vitro research. Through optimization of the parameters (flow rate, spinneret diameter, voltage, collector distance) for poly-ϵ-caprolactone, we could direct-write coherent scaffolds with ultrafine filaments, the smallest being 817 ± 165 nm. These low diameter filaments were deposited to form box-structures with a periodicity of 100.6 ± 5.1 μm and a height of 80 μm (50 stacked filaments; 100 overlap at intersections). We also observed oriented crystalline regions within such ultrafine filaments after annealing at 55 °C. The scaffolds were printed upon NCO-sP(EO-stat-PO)-coated glass slide surfaces and withstood frequent liquid exchanges with negligible scaffold detachment for at least 10 days in vitro.
There is a specialized niche for the electrohydrodynamic jetting of melts, from biomedical products to filtration and soft matter applications. The next frontier includes optics, microfluidics, flexible electronic devices, and soft network composites in biomaterial science and soft robotics. The recent emphasis on reproducibly direct‐writing continual molten jets has enabled a spectrum of contemporary microscale 3D objects to be fabricated. One strong suit of melt processing is the capacity for the jet to solidify rapidly into a fiber, thus fixing a particular structure into position. The ability to direct‐write complex and multiscaled architectures and structures has greatly contributed to a large number of recent studies, explicitly, toward fiber–hydrogel composites and fugitive inks, and has expanded into several biomedical applications such as cartilage, skin, periosteum, and cardiovascular tissue engineering. Following the footsteps of a publication that summarized melt electrowriting literature up to 2015, the most recent literature from then until now is reviewed to provide a continuous and comprehensive timeline that demonstrates the latest advances as well as new perspectives for this emerging technology.
Introduction
For both students and teachers, it is challenging to learn and teach a correct crown preparation. The purpose of this study was the design, feasibility and evaluation of a 3D printed tooth model with internal preparation for dental education in crown preparation and to analyse the quality of the prepared printed teeth in comparison with prepared standard model teeth.
Materials and methods
A printable tooth was designed and printed by a stereolithographic printer. 38 fourth‐year dental students in the first clinical course in prosthodontics were trained in a voluntary course using printed teeth. Different aspects of the printed tooth were evaluated by a questionnaire using German school grades (1 best to 5 worst). The quality of the preparation with the printed teeth and standard training teeth was also rated in an evaluation form done by an expert group consisting of five experienced dentists.
Results
The workflow was feasible and cost‐effective for the production of the teeth. The overall rating of the printed tooth was Ø 2.0 ± 0.34 in the questionnaire completed by the students. The students rated the printed tooth model (Ø 2.1 ± 0.85) as significantly better than the standard model tooth (Ø 3.3 ± 0.77; P = .000). The students reported great benefits in the use of this model tooth, for example valuable replacement of a standard model and real teeth, direct control of material loss. The quality of the preparation was evaluated by the expert group as significantly better with an overall mean grade of Ø 2.6 ± 0.37 for the printed teeth compared to Ø 2.9 ± 0.42 for the standard model teeth (P = .000).
Conclusions
The feasibility of this teaching concept was confirmed. The students favoured to work on the innovative 3D‐teeth with internal preparation, emphasising the usefulness of this technique in dental education. The expert group confirmed also the significant training effect of this tooth model in contrast to a standard model tooth.
Introduction
The preparation for dentin posts is difficult and hard to learn. There are currently no reproducible simulation models to train this clinical procedure. The purpose of this study was the design, feasibility and evaluation of a three‐dimensional (3D) printed tooth model for the pre‐clinical teaching of students.
Materials and methods
A printable tooth was designed and printed by a stereolithographic printer. A total of 48 fourth‐year dental students in the first clinical course in prosthodontics were trained in a voluntary hands‐on course on 4 similar printed teeth. The students used standard model teeth and real‐teeth models during their education. They had experience in caries removement and root canal treatment on real patients. Root perforations were counted for every attempt. The different benefits of the 3D printed tooth were evaluated by a questionnaire using German school grades from 1 (best) to 6 (worst).
Results
The overall rating of the printed tooth was Ø1.9 ± 0.3. The item “suitable exercise option” was rated Ø2.0 ± 0.8, and the teeth were “easy to use” Ø1.9 ± 0.9. The item “realistic approach to dentin post preparation” was rated Ø2.1 ± 0.8, and the teeth showed the “shortcomings at a root perforation” Ø1.5 ± 0.6. The students reported to have much more motivation and enthusiasm to improve their skills with the printed teeth Ø2.1 ± 0.9. They had a strong desire to include these teeth in their pre‐clinical education before the first patient treatment Ø1.6 ± 0.8. The success rate of the dentin post preparation was significantly better for the second 25% (P = .047) and fourth 48% (P = .04) attempt.
Conclusions
The feasibility of this teaching concept was confirmed. The students had the possibility to learn a correct dentin post preparation on a printed tooth model. The learning effect with this tooth model was rated as good to very good by the questionnaire.
Melt electrowriting, a high‐resolution additive manufacturing technology, has so far been developed with vertical stacking of fiber layers, with a printing trajectory that is constant for each layer. In this work, microscale layer shifting is introduced through deliberately offsetting the printing trajectory for each printed layer. Inaccuracies during the printing of sinusoidal walls are corrected via layer shifting, resulting in accurate control of their geometry and mechanical properties. Furthermore, more substantial layer shifting allows stacking of fiber layers in a horizontal manner, overcoming the electrostatic autofocusing effect that favors vertical layer stacking. Novel nonlinear geometries, such as overhangs, wall texturing and branching, and smooth and abrupt changes in printing trajectory are presented, demonstrating the flexibility of the layer shifting approach beyond the state‐of‐the‐art. The practice of microscale layer shifting for melt electrowriting enables more complex geometries that promise to have a profound impact on the development of products in a broad range of applications.
A method is reported for making hollow channels within hydrogels decorated with cell‐adhesion peptides exclusively at the channel surface. Sacrificial fibers of different diameters are used to introduce channels within poly(ethylene glycol) hydrogels crosslinked with maleimide‐thiol chemistry, which are backfilled with a cysteine‐containing peptide solution which is conjugated to the lumen with good spatial efficiency. This allows for peptide patterning in only the areas of the hydrogel where they are needed when used as cell‐guides, reducing the amount of required peptide 20‐fold when compared to bulk functionalization. The power of this approach is highlighted by successfully using these patterned hydrogels without active perfusion to guide fibroblasts and olfactory ensheathing cells—the latter having unique potential in neural repair therapies.
Hydrophilic (AB)\(_{n}\) Segmented Copolymers for Melt Extrusion‐Based Additive Manufacturing
(2021)
Several manufacturing technologies beneficially involve processing from the melt, including extrusion‐based printing, electrospinning, and electrohydrodynamic jetting. In this study, (AB)\(_{n}\) segmented copolymers are tailored for melt‐processing to form physically crosslinked hydrogels after swelling. The copolymers are composed of hydrophilic poly(ethylene glycol)‐based segments and hydrophobic bisurea segments, which form physical crosslinks via hydrogen bonds. The degree of polymerization was adjusted to match the melt viscosity to the different melt‐processing techniques. Using extrusion‐based printing, a width of approximately 260 µm is printed into 3D constructs, with excellent interlayer bonding at fiber junctions, due to hydrogen bonding between the layers. For melt electrospinning, much thinner fibers in the range of about 1–15 µm are obtained and produced in a typical nonwoven morphology. With melt electrowriting, fibers are deposited in a controlled way to well‐defined 3D constructs. In this case, multiple fiber layers fuse together enabling constructs with line width in the range of 70 to 160 µm. If exposed to water the printed constructs swell and form physically crosslinked hydrogels that slowly disintegrate, which is a feature for soluble inks within biofabrication strategies. In this context, cytotoxicity tests confirm the viability of cells and thus demonstrating biocompatibility of this class of copolymers.
Melt electrowriting (MEW) is a high-resolution additive manufacturing technology that balances multiple parametric variables to arrive at a stable fabrication process. The better understanding of this balance is underscored here using high-resolution camera vision of jet stability profiles in different electrical fields. Complementing this visual information are fiber-diameter measurements obtained at precise points, allowing the correlation to electrified jet properties. Two process signatures—the jet angle and for the first time, the Taylor cone area—are monitored and analyzed with a machine vision system, while SEM imaging for diameter measurement correlates real-time information. This information, in turn, allows the detection and correction of fiber pulsing for accurate jet placement on the collector, and the in-process assessment of the fiber diameter. Improved process control is used to successfully fabricate collapsible MEW tubes; structures that require exceptional accuracy and printing stability. Using a precise winding angle of 60° and 300 layers, the resulting 12 mm-thick tubular structures have elastic snap-through instabilities associated with mechanical metamaterials. This study provides a detailed analysis of the fiber pulsing occurrence in MEW and highlights the importance of real-time monitoring of the Taylor cone volume to better understand, control, and predict printing instabilities.
Purpose
Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time–activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative \(^{177}\)Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise.
Methods
The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities.
Results
Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla.
Conclusion
This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
Various (AB)\(_{n}\) and (ABAC)\(_{n}\) segmented copolymers with hydrophilic and hydrophobic segments are processed via melt electrowriting (MEW). Two different (AB)\(_{n}\) segmented copolymers composed of bisurea segments and hydrophobic poly(dimethyl siloxane) (PDMS) or hydrophilic poly(propylene oxide)-poly(ethylene oxide)-poly(propylene oxide) (PPO-PEG-PPO) segments, while the amphiphilic (ABAC)\(_{n}\) segmented copolymers consist of bisurea segments in the combination of hydrophobic PDMS segments and hydrophilic PPO-PEG-PPO segments with different ratios, are explored. All copolymer compositions are processed using the same conditions, including nozzle temperature, applied voltage, and collector distance, while changes in applied pressure and collector speed altered the fiber diameter in the range of 7 and 60 µm. All copolymers showed excellent processability with MEW, well-controlled fiber stacking, and inter-layer bonding. Notably, the surfaces of all four copolymer fibers are very smooth when visualized using scanning electron microscopy. However, the fibers show different roughness demonstrated with atomic force microscopy. The non-cytotoxic copolymers increased L929 fibroblast attachment with increasing PDMS content while the different copolymer compositions result in a spectrum of physical properties.