This thesis will outline studies performed on the fluorescence dynamics of phenyl-benzo-
[c]-tetrazolo-cinnolium chloride (PTC) in alcoholic solutions with varying viscosity using
time-resolved fluoro-spectroscopic methods. Furthermore, the properties of femtosecond
Laguerre-Gaussian (LG) laser pulses will be investigated with respect to their temporal
and spatial features and an approach will be developed to measure and control the spatial
intensity distribution on the time scale of the pulse.
Tetrazolium salts are widely used in biological assays for their low oxidation and reduction
thresholds and spectroscopic properties. However, a neglected feature in these applications
is the advantage that detection of emitted light has over the determination of the
absorbance. To corroborate this, PTC as one of the few known fluorescent tetrazolium
salts was investigated with regard to its luminescent features. Steady-state spectroscopy
revealed how PTC can be formed by a photoreaction from 2,3,5-triphenyl-tetrazolium
chloride (TTC) and how the fluorescence quantum yield behaved in alcoholic solvents
with different viscosity. In the same array of solvents time correlated single photon counting
(TCSPC) measurements were performed and the fluorescence decay was investigated.
Global analysis of the results revealed different dynamics in the different solvents, but
although the main emission constant did change with the solvent, taking the fluorescence
quantum yield into consideration resulted in an independence of the radiative rate from
the solvent. The non-radiative rate, however, was highly solvent dependent and responsible
for the observed solvent-related changes in the fluorescence dynamics. Further studies
with the increased time resolution of femtosecond fluorescence upconversion revealed an
independence of the main emission constant from the excitation energy, however the dynamics
of the cooling processes prior to emission were prolonged for higher excitation
energy. This led to a conceivable photoreaction scheme with one emissive state with a
competing non-radiative relaxation channel, that may involve an intermediate state.
LG laser beams and their properties have seen a lot of scientific attention over the past two
decades. Also in the context of new techniques pushing the limit of technology further to
explore new phenomena, it is essential to understand the features of this beam class and
check the consistency of the findings with theoretical knowledge. The mode conversion
of a Hermite-Gaussian (HG) mode into a LG mode with the help of a spiral phase plate
(SPP) was investigated with respect to its space-time characteristics. It was found that
femtosecond LG and HG pulses of a given temporal duration share the same spectrum
and can be characterized using the same well-established methods. The mode conversion
proved to only produce the desired LG mode with its characteristic orbital angular momentum
(OAM), that is conserved after frequency doubling the pulse. Furthermore, it
was demonstrated that temporal shaping of the HG pulse does not alter the result of its
mode-conversion, as three completely different temporal pulse shapes produced the same
LG mode. Further attention was given to the sum frequency generation of fs LG beams
and dynamics of the interference of a HG and a LG pulse. It was found that if both are
chirped with inverse signs the spatial intensity distribution does rotate around the beam
axis on the time scale of the pulse. A strategy was found that would enable a measurement
of these dynamics by upconversion of the interference with a third gate pulse. The results
of which are discussed theoretically and an approach of an experimental realization had
been made. The simulated findings had only been reproduced to a limited extend due to
experimental limitations, especially the interferometric stability of the setup.