Refine
Is part of the Bibliography
- yes (131)
Year of publication
Document Type
- Journal article (123)
- Doctoral Thesis (7)
- Preprint (1)
Language
- English (131) (remove)
Keywords
- magnetic resonance imaging (10)
- MRI (8)
- CT angiography (4)
- deep learning (4)
- multiple myeloma (4)
- Bildgebendes Verfahren (3)
- Medizin (3)
- cardiac magnetic resonance imaging (3)
- endovascular (3)
- lung (3)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (131) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
Background
Merkel cell carcinoma (MCC) is a rare cutaneous neoplasm with increasing incidence, aggressive behavior and poor prognosis. Somatostatin receptors (SSTR) are expressed in MCC and represent a potential target for both imaging and treatment.
Methods
To non-invasively assess SSTR expression in MCC using PET and the radiotracers [68Ga]DOTA-D-Phe1-Tyr3-octreotide (DOTATOC) or -octreotate (DOTATATE) as surrogate for tumor burden. In 24 patients with histologically proven MCC SSTR-PET was performed and compared to results of computed tomography (CT).
Results
SSTR-PET detected primary and metastatic MCC lesions. On a patient-based analysis, sensitivity of SSTR-PET was 73% for nodal metastases, 100% for bone, and 67% for soft-tissue metastases, respectively. Notably, brain metastases were initially detected by SSTR-PET in 2 patients, whereas liver and lung metastases were diagnosed exclusively by CT. SSTR-PET showed concordance to CT results in 20 out of 24 patients. Four patients (17%) were up-staged due to SSTR-PET and patient management was changed in 3 patients (13%).
Conclusion
SSTR-PET showed high sensitivity for imaging bone, soft tissue and brain metastases, and particularly in combination with CT had a significant impact on clinical stage and patient management.
This study aimed to explore the correlation between imaging patterns and clinical features in patients with smoldering multiple myeloma (SMM) who simultaneously underwent 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT). We retrieved and analyzed clinical characteristics and PET imaging data of 10 patients with SMM. We found a significant correlation between bone marrow (BM) plasma cell (PC) infiltration and mean standardized uptake values (SUV\(_{mean}\)) of lumbar vertebrae L2-L4 on 11C-Methionine PET/CT scans (r = 0.676, p = 0.031) and 68Ga-Pentixafor PET/CT scans (r = 0.839, p = 0.002). However, there was no significant correlation between BM involvement and SUV\(_{mean}\) of lumbar vertebrae L2-L4 on 18F-FDG PET/CT scans (r = 0.558, p = 0.093). Similarly, mean target-to-background ratios (TBR\(_{mean}\)) of lumbar vertebrae L2-L4 also correlated with bone marrow plasma cell (BMPC) infiltration in 11C-Methionine PET/CT (r = 0.789, p = 0.007) and 68Ga-Pentixafor PET/CT (r = 0.724, p = 0.018) PET/CT. In contrast, we did not observe a significant correlation between BMPC infiltration rate and TBR\(_{mean}\) in 18F-FDG PET/CT (r = 0.355, p = 0.313). Additionally, on 11C-Methionine PET/CT scans, we found a significant correlation between BMPC infiltration and TBR\(_{max}\) of lumbar vertebrae L2-L4 (r = 0.642, p = 0.045). In conclusion, 11C-Methionine and 68Ga-Pentixafor PET/CT demonstrate higher sensitivity than 18F-FDG PET/CT in detecting BM involvement in SMM.
Background
Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI.
Methods
49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated.
Results
Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PD\(_{outflow}\)/PD\(_{inflow}\) increased by 65% (p < 0.001) and AUC\(_{outflow}\)/AUC\(_{inflow}\) increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05).
Conclusions
Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.
Background
Elbow imaging is challenging with conventional multidetector computed tomography (MDCT), while cone-beam CT (CBCT) provides superior options. We compared intra-individually CBCT versus MDCT image quality in cadaveric elbows.
Methods
A twin robotic x-ray system with new CBCT mode and a high-resolution clinical MDCT were compared in 16 cadaveric elbows. Both systems were operated with a dedicated low-dose (LD) protocol (equivalent volume CT dose index [CTDI\(_{vol(16 cm)}\)] = 3.3 mGy) and a regular clinical scan dose (RD) protocol (CTDI\(_{vol(16 cm)}\) = 13.8 mGy). Image quality was evaluated by two radiologists (R1 and R2) on a seven-point Likert scale, and estimation of signal intensity in cancellous bone was conducted. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) statistics were used.
Results
The CBCT prototype provided superior subjective image quality compared to MDCT scans (for RD, p ≤ 0.004; for LD, p ≤ 0.001). Image quality was rated very good or excellent in 100% of the cases by both readers for RD CBCT, 100% (R1) and 93.8% (R2) for LD CBCT, 62.6% and 43.8% for RD MDCT, and 0.0% and 0.0% for LD MDCT. Single-measure ICC was 0.95 (95% confidence interval 0.91–0.97; p < 0.001). Software-based assessment supported subjective findings with less “undecided” pixels in CBCT than dose-equivalent MDCT (p < 0.001). No significant difference was found between LD CBCT and RD MDCT.
Conclusions
In cadaveric elbow studies, the tested cone-beam CT prototype delivered superior image quality compared to high-end multidetector CT and showed a potential for considerable dose reduction.
Background
Solitary metastases to the pancreas are rare. Therefore the value of resection in curative intention remains unclear. In the literature there are several promising reports about resection of solitary metastasis to the pancreas mainly of renal origin.
Case presentation
Here we report for the first time on the surgical therapy of a 1.5 cm solitary pancreatic metastasis of an adrenocortical carcinoma. The metastasis occurred almost 6 years after resection of the primary tumor. A partial pancreatoduodenectomy was performed and postoperatively adjuvant mitotane treatment was initiated. During the follow-up of 3 years after surgery no evidence of tumor recurrence occurred.
Conclusion
Resection of pancreatic tumors should be considered, even if the mass is suspicious for metastatic disease including recurrence of adrenocortical cancer.
Purpose
Image acquisition and subsequent manual analysis of cardiac cine MRI is time-consuming. The purpose of this study was to train and evaluate a 3D artificial neural network for semantic segmentation of radially undersampled cardiac MRI to accelerate both scan time and postprocessing.
Methods
A database of Cartesian short-axis MR images of the heart (148,500 images, 484 examinations) was assembled from an openly accessible database and radial undersampling was simulated. A 3D U-Net architecture was pretrained for segmentation of undersampled spatiotemporal cine MRI. Transfer learning was then performed using samples from a second database, comprising 108 non-Cartesian radial cine series of the midventricular myocardium to optimize the performance for authentic data. The performance was evaluated for different levels of undersampling by the Dice similarity coefficient (DSC) with respect to reference labels, as well as by deriving ventricular volumes and myocardial masses.
Results
Without transfer learning, the pretrained model performed moderately on true radial data [maximum number of projections tested, P = 196; DSC = 0.87 (left ventricle), DSC = 0.76 (myocardium), and DSC =0.64 (right ventricle)]. After transfer learning with authentic data, the predictions achieved human level even for high undersampling rates (P = 33, DSC = 0.95, 0.87, and 0.93) without significant difference compared with segmentations derived from fully sampled data.
Conclusion
A 3D U-Net architecture can be used for semantic segmentation of radially undersampled cine acquisitions, achieving a performance comparable with human experts in fully sampled data. This approach can jointly accelerate time-consuming cine image acquisition and cumbersome manual image analysis.
Background
Lipoblastoma is a rare benign mesenchymal neoplasm of infancy that most commonly occurs on the extremities and trunk but can arise at variable sites of the body. Retroperitoneal lipoblastomas are particularly rare but can grow to enormous size, and preoperative diagnosis is difficult with diverse, mostly malignant differential diagnoses that would lead to aggressive therapy. Since lipoblastoma is a benign tumor that has an excellent prognosis after resection, correct diagnosis is crucial.
Case presentation
A case of a large retroperitoneal tumor of a 24-month old infant that was clinically suspicious of a malignant tumor is presented. Due to proximity to the right kidney, clinically most probably a nephroblastoma or clear cell sarcoma of the kidney was suspected. Radiological findings were ambiguous. Therefore, the mass was biopsied, and histology revealed an adipocytic lesion. Although mostly composed of mature adipocytes, in view of the age of the patient, the differential diagnosis of a (maturing) lipoblastoma was raised, which was supported by molecular analysis demonstrating a HAS2-PLAG1 fusion. The tumor was completely resected, and further histopathological workup led to the final diagnosis of a 13 cm large retroperitoneal maturing lipoblastoma. The child recovered promptly from surgery and showed no evidence of recurrence so far.
Conclusion
Although rare, lipoblastoma should be included in the differential diagnoses of retroperitoneal tumors in infants and children, and molecular diagnostic approaches could be a helpful diagnostic adjunct in challenging cases.
This work deals with the acceleration of cardiovascular MRI for the assessment
of functional information in steady-state contrast and for viability assessment
during the inversion recovery of the magnetization. Two approaches
are introduced and discussed in detail. MOCO-MAP uses an exponential
model to recover dynamic image data, IR-CRISPI, with its low-rank plus
sparse reconstruction, is related to compressed sensing.
MOCO-MAP is a successor to model-based acceleration of parametermapping
(MAP) for the application in the myocardial region. To this end, it
was augmented with a motion correction (MOCO) step to allow exponential
fitting the signal of a still object in temporal direction. Iteratively, this
introduction of prior physical knowledge together with the enforcement of
consistency with the measured data can be used to reconstruct an image
series from distinctly shorter sampling time than the standard exam (< 3 s
opposed to about 10 s). Results show feasibility of the method as well as
detectability of delayed enhancement in the myocardium, but also significant
discrepancies when imaging cardiac function and artifacts caused already by
minor inaccuracy of the motion correction.
IR-CRISPI was developed from CRISPI, which is a real-time protocol
specifically designed for functional evaluation of image data in steady-state
contrast. With a reconstruction based on the separate calculation of low-rank
and sparse part, it employs a softer constraint than the strict exponential
model, which was possible due to sufficient temporal sampling density via
spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on
dynamic and on inversion recovery data. Thus, motion correction is rendered
unnecessary with it.
IR-CRISPI was equipped with noise suppression via spatial wavelet filtering.
A study comprising 10 patients with cardiac disease show medical
applicability. A comparison with performed traditional reference exams offer
insight into diagnostic benefits. Especially regarding patients with difficulty
to hold their breath, the real-time manner of the IR-CRISPI acquisition provides
a valuable alternative and an increase in robustness.
In conclusion, especially with IR-CRISPI in free breathing, a major acceleration
of the cardiovascular MR exam could be realized. In an acquisition
of less than 100 s, it not only includes the information of two traditional
protocols (cine and LGE), which take up more than 9.6 min, but also allows
adjustment of TI in retrospect and yields lower artifact level with similar
image quality.
Introduction
In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities.
Materials and methods
Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded.
Results
Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up.
Conclusions
Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury.