The relation between LV function and cardiac MRI tissue characteristics in separate myocardial segments and their change over time has yet to be explored in myocarditis. Thus, our research aimed to investigate possible associations between global and regional myocardial T1 and T2 times and peak strain in patients with suspected myocarditis.
From 2012 to 2015, 129 patients with clinically suspected myocarditis of the prospective, observational MyoRacer-Trial underwent systematic biventricular EMB at baseline and cardiac MRI at baseline and after three months as a follow-up. We divided the LV myocardium into 17 segments and estimated the segmental myocardial strain using FT. We registered T1 and T2 maps to the cine sequences and transferred the segmentations used for FT to ensure conformity of the myocardial segments. Multi-level multivariable linear mixed effects regression was applied to investigate the relation of segmental myocardial strain to relaxation times and their respective change from baseline to follow-up.
We found a significant improvement in myocardial peak strain from baseline to follow-up (p < 0.001; all p-values given for likelihood ratio tests) and significant associations between higher T1 and T2 times and lower segmental myocardial peak strain (p ranging from < 0.001 to 0.049). E.g., regression coefficient (Reg. coef.) for segmental radial peak strain in short axis view (SRPS_SAX) and T1 time: -1.9, 95% CI (-2.6;-1.2) %/100 ms, p < 0.001. A decrease in T1 and T2 times from baseline to follow-up was also significantly related to a recovery of segmental peak strains (p ranging from < 0.001 to 0.050). E.g., Reg. coef. for SRPS_SAX per ΔT1: -1.8, 95% CI (-2.5;-1.0) %/100 ms, p < 0.001. Moreover, the higher the baseline T1 time, the more substantial the functional recovery from baseline to follow-up (p ranging from 0.004 to 0.042, e.g., for SRPS_SAX: Reg. coef. 1.3, 95% CI (0.4;2.1) %/100 ms, p 0.004). We did not find an effect modification by the presence of myocarditis in the EMB (p > 0.1).
Our cross-sectional and longitudinal analyses provide evidence of dose-dependent correlations between T1 and T2 relaxation times and myocardial peak strain in patients with clinical presentation of myocarditis, regardless of the EMB result. Thus, assessing strain values and mapping relaxation times helps estimate the functional prognosis in patients with clinically suspected myocarditis.
Cardiovascular disease is one of the leading causes of death worldwide and, so far, echocardiography, nuclear cardiology, and catheterization are the gold standard techniques used for its detection. Cardiac magnetic resonance (CMR) can replace the invasive imaging modalities and provide a "one-stop shop" characterization of the cardiovascular system by measuring myocardial tissue structure, function and perfusion of the heart, as well as anatomy of and flow in the coronary arteries. In contrast to standard clinical magnetic resonance imaging (MRI) scanners, which are often operated at a field strength of 1.5 or 3 Tesla (T), a higher resolution and subsequent cardiac parameter quantification could potentially be achieved at ultra-high field, i.e., 7 T and above.
Unique insights into the pathophysiology of the heart are expected from ultra-high field MRI, which offers enhanced image quality in combination with novel contrast mechanisms, but suffers from spatio-temporal B0 magnetic field variations. Due to the resulting spatial misregistration and intra-voxel dephasing, these B0-field inhomogeneities generate a variety of undesired image artifacts, e.g., artificial image deformation. The resulting macroscopic field gradients lead to signal loss, because the effective transverse relaxation time T2* is shortened. This affects the accuracy of T2* measurements, which are essential for myocardial tissue characterization. When steady state free precession-based pulse sequences are employed for image acquisition, certain off-resonance frequencies cause signal voids. These banding artifacts complicate the proper marking of the myocardium and, subsequently, systematic errors in cardiac function measurements are inevitable. Clinical MR scanners are equipped with basic shim systems to correct for occurring B0-field inhomogeneities and resulting image artifacts, however, these are not sufficient for the advanced measurement techniques employed for ultra-high field MRI of the heart.
Therefore, this work focused on the development of advanced B0 shimming strategies for CMR imaging applications to correct the spatio-temporal B0 field variations present in the human heart at 7 T. A novel cardiac phase-specific shimming (CPSS) technique was set up, which featured a triggered B0 map acquisition, anatomy-matched selection of the shim-region-of-interest (SROI), and calibration-based B0 field modeling. The influence of technical limitations on the overall spherical harmonics (SH) shim was analyzed. Moreover, benefits as well as pitfalls of dynamic shimming were debated in this study. An advanced B0 shimming strategy was set up and applied in vivo, which was the first implementation of a heart-specific shimming approach in human UHF MRI at the time.
The spatial B0-field patterns which were measured in the heart throughout this study contained localized spots of strong inhomogeneities. They fluctuated over the cardiac cycle in both size and strength, and were ideally addressed using anatomy-matched SROIs. Creating a correcting magnetic field with one shim coil, however, generated eddy currents in the surrounding conducting structures and a resulting additional, unintended magnetic field. Taking these shim-to-shim interactions into account via calibration, it was demonstrated for the first time that the non-standard 3rd-order SH terms enhanced B0-field homogeneity in the human heart. However, they were attended by challenges for the shim system hardware employed in the presented work, which was indicated by the currents required to generate the optimal 3rd-order SH terms exceeding the dynamic range of the corresponding shim coils. To facilitate dynamic shimming updated over the cardiac cycle for cine imaging, the benefit of adjusting the oscillating CPSS currents was found to be vital. The first in vivo application of the novel advanced B0 shimming strategy mostly matched the simulations.
The presented technical developments are a basic requirement to quantitative and functional CMR imaging of the human heart at 7 T. They pave the way for numerous clinical studies about cardiac diseases, and continuative research on dedicated cardiac B0 shimming, e.g., adapted passive shimming and multi-coil technologies.
Acceleration is a central aim of clinical and technical research in magnetic resonance imaging (MRI) today, with the potential to increase robustness, accessibility and patient comfort, reduce cost, and enable entirely new kinds of examinations. A key component in this endeavor is image reconstruction, as most modern approaches build on advanced signal and image processing. Here, deep learning (DL)-based methods have recently shown considerable potential, with numerous publications demonstrating benefits for MRI reconstruction. However, these methods often come at the cost of an increased risk for subtle yet critical errors. Therefore, the aim of this thesis is to advance DL-based MRI reconstruction, while ensuring high quality and fidelity with measured data. A network architecture specifically suited for this purpose is the variational network (VN). To investigate the benefits these can bring to non-Cartesian cardiac imaging, the first part presents an application of VNs, which were specifically adapted to the reconstruction of accelerated spiral acquisitions. The proposed method is compared to a segmented exam, a U-Net and a compressed sensing (CS) model using qualitative and quantitative measures. While the U-Net performed poorly, the VN as well as the CS reconstruction showed good output quality. In functional cardiac imaging, the proposed real-time method with VN reconstruction substantially accelerates examinations over the gold-standard, from over 10 to just 1 minute. Clinical parameters agreed on average.
Generally in MRI reconstruction, the assessment of image quality is complex, in particular for modern non-linear methods. Therefore, advanced techniques for precise evaluation of quality were subsequently demonstrated.
With two distinct methods, resolution and amplification or suppression of noise are quantified locally in each pixel of a reconstruction. Using these, local maps of resolution and noise in parallel imaging (GRAPPA), CS, U-Net and VN reconstructions were determined for MR images of the brain. In the tested images, GRAPPA delivers uniform and ideal resolution, but amplifies noise noticeably. The other methods adapt their behavior to image structure, where different levels of local blurring were observed at edges compared to homogeneous areas, and noise was suppressed except at edges. Overall, VNs were found to combine a number of advantageous properties, including a good trade-off between resolution and noise, fast reconstruction times, and high overall image quality and fidelity of the produced output. Therefore, this network architecture seems highly promising for MRI reconstruction.
This work deals with the acceleration of cardiovascular MRI for the assessment
of functional information in steady-state contrast and for viability assessment
during the inversion recovery of the magnetization. Two approaches
are introduced and discussed in detail. MOCO-MAP uses an exponential
model to recover dynamic image data, IR-CRISPI, with its low-rank plus
sparse reconstruction, is related to compressed sensing.
MOCO-MAP is a successor to model-based acceleration of parametermapping
(MAP) for the application in the myocardial region. To this end, it
was augmented with a motion correction (MOCO) step to allow exponential
fitting the signal of a still object in temporal direction. Iteratively, this
introduction of prior physical knowledge together with the enforcement of
consistency with the measured data can be used to reconstruct an image
series from distinctly shorter sampling time than the standard exam (< 3 s
opposed to about 10 s). Results show feasibility of the method as well as
detectability of delayed enhancement in the myocardium, but also significant
discrepancies when imaging cardiac function and artifacts caused already by
minor inaccuracy of the motion correction.
IR-CRISPI was developed from CRISPI, which is a real-time protocol
specifically designed for functional evaluation of image data in steady-state
contrast. With a reconstruction based on the separate calculation of low-rank
and sparse part, it employs a softer constraint than the strict exponential
model, which was possible due to sufficient temporal sampling density via
spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on
dynamic and on inversion recovery data. Thus, motion correction is rendered
unnecessary with it.
IR-CRISPI was equipped with noise suppression via spatial wavelet filtering.
A study comprising 10 patients with cardiac disease show medical
applicability. A comparison with performed traditional reference exams offer
insight into diagnostic benefits. Especially regarding patients with difficulty
to hold their breath, the real-time manner of the IR-CRISPI acquisition provides
a valuable alternative and an increase in robustness.
In conclusion, especially with IR-CRISPI in free breathing, a major acceleration
of the cardiovascular MR exam could be realized. In an acquisition
of less than 100 s, it not only includes the information of two traditional
protocols (cine and LGE), which take up more than 9.6 min, but also allows
adjustment of TI in retrospect and yields lower artifact level with similar
image quality.
In this work, accelerated non-Cartesian Magnetic Resonance Imaging (MRI) methods were established and applied to cardiovascular imaging (CMR) at different magnetic field strengths (3T and 7T).
To enable rapid data acquisition, highly efficient spiral k-space trajectories were created. In addition, hybrid sampling patterns such as the twisting radial lines (TWIRL) k-space trajectory were studied.
Imperfections of the dynamic gradient system of a MR scanner result in k-space sampling errors. Ultimately, these errors can lead to image artifacts in non-Cartesian acquisitions.
Among other reasons such as an increased reconstruction complexity, they cause the lack of spiral sequences in clinical routine compared to standard Cartesian imaging.
Therefore, the Gradient System Transfer Functions (GSTFs) of both scanners were determined and used for k-space trajectory correction in post-correction as well as in terms of a pre-emphasis.
The GSTF pre-emphasis was implemented as a fully automatic procedure, which enabled a precise correction of arbitrary gradient waveforms for double-oblique slice orientations.
Consequently, artifacts due to trajectory errors could be mitigated, which resulted in high image quality in non-Cartesian MRI.
Additionally, the GSTF correction was validated by measuring pre-emphasized spiral gradient outputs, which showed high agreement with the theoretical gradient waveforms.
Furthermore, it could be demonstrated that the performance of the GSTF correction is superior to a simple delay compensation approach.
The developed pulse sequences were applied to gated as well as real-time CMR. Special focus lied on the implementation of a spiral imaging protocol to resolve the beating heart of animals and humans in real time and free breathing.
In order to achieve real-time CMR with high spatiotemporal resolution, k-space undersampling was performed. For this reason, efficient sampling strategies were developed with the aim to facilitate compressed sensing (CS) during image reconstruction.
The applied CS approach successfully removed aliasing artifacts and yielded high-resolution cardiac image series. Image reconstruction was performed offline in all cases such that the images were not available immediately after acquisition at the scanner.
Spiral real-time CMR could be performed in free breathing, which led to an acquisition time of less than 1 minute for a whole short-axis stack.
At 3T, the results were compared to the gold standard of electrocardiogram-gated Cartesian CMR in breath hold, which revealed similar values for important cardiovascular functional and volumetric parameters.
This paves the way to an application of the developed framework in clinical routine of CMR.
In addition, the spiral real-time protocol was transferred to swallowing and speech imaging at 3T, and first images were presented.
The results were of high quality and confirm the straightforward utilization of the spiral sequence in other fields of MRI.
In general, the GSTF correction yielded high-quality images at both field strengths, 3T and 7T.
Off-resonance related blurring was mitigated by applying non-Cartesian readout gradients of short duration. At 7T, however, B1-inhomogeneity led to image artifacts in some cases.
All in all, this work demonstrated great advances in accelerating the MRI process by combining efficient, undersampled non-Cartesian k-space coverage with CS reconstruction.
Trajectory correction using the GSTF can be implemented at any scanner model and enables non-Cartesian imaging with high image quality.
Especially MRI of dynamic processes greatly benefits from the presented rapid imaging approaches.
Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung
(2019)
In this thesis, a 3D Ultrashort echo time (3D-UTE) sequence was introduced in the Self-gated Non-Contrast-Enhanced Functional Lung Imaging (SENCEFUL) framework. The sequence was developed and implemented on a 3 Tesla MR scanner. The 3D-UTE technique consisted of a nonselective RF pulse followed by a koosh ball quasi-random sampling order of the k-space. Measurements in free-breathing and without contrast agent were performed in healthy subjects and a patient with lung cancer.
A gating technique, using a combination of different coils with high signal correlation, was evaluated in-vivo and compared with a manual approach of coil selection. The gating signal offered an estimation of the breathing motion during measurement and was used as a reference to segment the acquired data into different breathing phases.
Gradient delays and trajectory errors were corrected during post-processing using the Gradient Impulse Response Function. Iterative SENSE was then applied to determine the fully sampled data.
In order to eliminate signal changes caused by motion, a 3D image registration was employed, and the results were compared to a 2D image registration method.
Ventilation was assessed in 3D and regionally quantified by monitoring the signal changes in the lung parenchyma. Finally, image quality and quantitative ventilation values were compared to the standard 2D-SENCEFUL technique.
3D-UTE, combined with an automatic gating technique and SENCEFUL MRI, offered ventilation maps with high spatial resolution and SNR. Compared to the 2D method, UTE-SENCEFUL greatly improved the clinical quality of the structural images and the visualization of the lung parenchyma.
Through‐plane motion, partial volume effects and ventilation artifacts were also reduced with a three-dimensional method for image registration.
UTE-SENCEFUL was also able to quantify regional ventilation and presented similar results to previous studies.
Neuroimaging research has highlighted the relevance of well-balanced functional brain interactions as an essential basis for efficient emotion regulation. In contrast, abnormal coupling of fear-processing regions such as the amygdala, the anterior cingulate cortex (ACC) and the insula could be an important feature of anxiety disorders. Although activity alterations of these regions have been frequently reported in specific phobia, little is known about their functional interactions during phobogenic stimulus processing.
To explore these interrelationships in two subtypes of specific phobia – i.e., the blood-injection-injury subtype and the animal subtype – functional connectivity (FC) was analyzed in three fMRI studies. Two studies examined fear processing in a dental phobia group (DP), a snake phobia group (SP) and a healthy control group (HC) during visual phobogenic stimuli presentation while a third study investigated differences between auditory and visual stimuli presentation in DP and HC.
Due to a priori hypotheses of impaired interactions between the amygdala, the ACC and the insula, a first analysis was conducted to explore the FC within these three regions of interest. Based on emerging evidence of functionally diverse subregions, the ACC was further divided into a subgenual, pregenual and dorsal ACC and the insula was divided into a ventral-anterior, dorsal-anterior and posterior region. Additionally, an exploratory seed-to-voxel analysis using the amygdala, ACC and insula as seeds was conducted to scan for connectivity patterns across the whole brain.
The analyses revealed a negative connectivity of the ACC and the amygdala during phobogenic stimulus processing in controls. This connectivity was predominantly driven by the affective ACC subdivision. By contrast, SP was characterized by an increased mean FC between the examined regions. Interestingly, this phenomenon was specific for auditory, but not visual symptom provocation in DP. During visual stimulus presentation, however, DP exhibited further FC alterations of the ACC and the insula with pre- and orbitofrontal regions.
These findings mark the importance of balanced interactions between fear-processing regions in specific phobia, particularly of the inhibitory connectivity between the ACC and the amygdala. Theoretically, this is assumed to reflect top-down inhibition by the ACC during emotion regulation. The findings support the suggestion that SP particularly is characterized by excitatory, or missing inhibitory, (para-) limbic connectivity, reflecting an overshooting fear response based on evolutionary conserved autonomic bottom-up pathways. Some of these characteristics applied to DP as well but only under the auditory stimulation, pointing to stimulus dependency. DP was further marked by altered pre- and orbitofrontal coupling with the ACC and the insula which might represent disturbances of superordinate cognitive control on basal emotion processes. These observations strengthen the assumption that DP is predominantly based on evaluation-based fear responses.
In conclusion, the connectivity patterns found may depict an intermediate phenotype that possibly confers risks for inappropriate phobic fear responses. The findings presented could also be of clinical interest. Particularly the ACC – amygdala circuit may be used as a predictive biomarker for treatment response or as a promising target for neuroscience-focused augmentation strategies as neurofeedback or repetitive transcranial magnetic stimulation.
The noninvasive magnetic resonance imaging technique allows for the investigation of functional processes in the living plant. For this purpose during this work, different NMR imaging methods were further developed and applied.
For the localisation of the intrusion of water into the germinating rape seed with the simultaneous depiction of the lipid-rich tissue via a 3D rendering, in Chap. 5 the technique of interleaved chemical selective acquisition of water and lipid was used in the germinating seed. The utilization of high-resolution MR images of germinated seeds enabled the localization of a predetermined water gap in the lipid-rich aleurone layer, which resides directly under the seed coat. The for a long time in biology prevalent discussion, whether such a gap exists or the seed soaks up the water from all sides, rather like a sponge, could hereby, at least for the rapeseed seed, be answered clearly. Furthermore, the segmentation and 3D visualization of the vascular tissue in the rapeseed seeds was enabled by the high-resolution datasets, a multiply branched structure preconstructed in the seed could be shown. The water is directed by the vascular tissue and thus awakens the seed gradually to life. This re-awakening could as well be tracked by means of invasive imaging via an oxygen sensor. In the re-awakened seeds, the lipid degradation starts, other than expected, not in the lipid-rich cotyledons but in the residual endosperm remaining from seed development and in the aleurone layer which previously protected the embryo. Within this layer, the degradation could be verified in the high-resolution MR datasets.
The method presented in Chap. 6 provides a further characteristic trait for phenotyping of seeds and lipid containing plants in general. The visualization of the compounds of fatty acids in plant seeds and fruits could be achieved by the distinct utilization of chemical shift-selective imaging techniques. Via the application of a CSI sequence the fatty acid compounds in an olive were localized in a 2D slice. In conjunction with an individually adjusted CHESS presaturation module Haa85 the high-resolution 3D visualization of saturated and unsaturated fatty acid compounds in different seeds was achieved. The ratio maps calculated from these datasets allow to draw conclusions from the developmental stage or the type of seed. Furthermore, it could be shown that the storage condition of two soybean seeds with different storage time durations lead to no degradation of the fatty acid content.
Additional structural information from inside of dry seeds are now accessible via MRI. In this work the imaging of cereal seeds could be significantly improved by the application of the UTE sequence. The hitherto existing depictions of the lipid distribution, acquired with the spin echo sequence, were always sufficient for examinations of the lipid content, yet defects in the starchy endosperm or differences in the starch concentration within the seed remained constantly unseen with this technique. In a direct comparison of the datasets acquired with the previous imaging technique (spin echo) and with UTE imaging, the advantage of data acquisition with UTE could be shown. By investigating the potential seed compounds (starch, proteins, sugar) in pure form, the constituent parts contributing to the signal could be identified as bound water (residual moisture) and starch. The application of a bi-exponential fit on the datasets of the barley seed enabled the separate mapping of magnetization and of relaxation time of two components contributing to the NMR signal. The direct comparison with histological stainings verified the previous results, thus this technique can be used for the selective imaging of starch in dry seeds.
Conclusions on the translocation characteristics in plants can be drawn by the technique proposed in Chap. 8. The associated translocation velocities can now, even in the range of several um/h, be determined in the living plant. Based on calculated concentrations of an MR contrast agent, which was taken up by the plant, these translocation velocities were estimated both in longitudinal direction, thus along the vascular bundle, and in horizontal direction, thus out of the bundle. The latter velocity is located below the contrast agent's velocity value of free diffusion. By adjusting a dynamic contrast-enhancing imaging technique (DCE-Imaging, Tof91) the acquisition duration of a T1-map was significantly reduced. By means of these maps, local concentrations of the contrast agent in plant stems and the siliques of the rapeseed plant could be determined.
Numerous questions in plant science can only be answered by non-invasive techniques such as MRI. For this reason, besides the experimental results achieved in this work, further NMR methods were tested and provided for the investigation of plants.
As an example, the study on the imaging of magnetic exchange processes are mentioned, which provided the groundwork for a possible transfer of CEST experiments (Chemical Exchange Saturation Transfer) to the plant. The results are presented in the bachelor thesis of A. Jäger Jae17, which was performed under my supervision, they find great interest under biologists.
The development of new technologies, which extend the possibilities for the investigation of living organisms, is of great importance. For this reason, I have contributed to the development of the currently unpublished method RACETE (Refocused Acquisition of Chemical Exchange Transferred Excitations [Jak17, Reu17, Gut18a]). By rephasing the transferred magnetization the utilization of properties which have not been available in chemical "`exchange"' experiments is enabled. With this method a positive contrast is generated, thus a reference experiment is not mandatory. Furthermore, the image phase, which in classical experiments contains no information about the exchanged protons, can be used for the distinct identification of multiple substances which have been excited simultaneously.
This recently at the Department of Experimental Physics V developed method can be used in particular for the identification of lipids and for the localization of sugars and amino acids, thus it can serve the enhancement and improvement of non-invasive analytical methods.
This work considered the frequency-modulated balanced steady-state free precession (fm-bSSFP) sequence as a tool to provide banding free bSSFP MR images. The sequence was implemented and successfully applied to suppress bandings in various in vitro and in vivo examples. In combination with a radial trajectory it is a promising alternative for standard bSSFP applications. First, two specialized applications were shown to establish the benefits of the acquisition strategy in itself. In real time cardiac imaging, it was shown that the continuous shift in frequency causes a movement of the bandings across the FOV. Thus, no anatomical region is constantly impaired, and a suitable timeframe can be found to examine all important structures. Furthermore, a combination of images with different artifact positions, similar to phase-cycled acquisitions is possible. In this way, fast, banding-free imaging of the moving heart was realized. Second, acquisitions with long TR were shown. While standard bSSFP suffers from increasing incidence of bandings with higher TR values, the frequency-modulated approach provided banding free images, regardless of the TR.
A huge disadvantage of fm-bSSFP, in combination with the radial trajectory, is the decrease in signal intensity. In this work a specialized reconstruction method, the multifrequency reconstruction for frequency-modulated bSSFP (Muffm), was established, which successfully compensated that phenomena. The application of Muffm to several anatomical sites, such as inner ear, legs and cardiac acquisitions, proofed the advantageous SNR of the reconstruction.
Furthermore, fm-bSSFP was applied to the clinically highly relevant task of water-fat separation. Former approaches of a phase-sensitive separation procedure in combination with standard bSSFP showed promising results but failed in cases of high inhomogeneity or high field strengths where banding artifacts become a major issue. The novel approach of using the fm-bSSFP acquisition strategy with the separation approach provided robust, reliable images of high quality. Again, losses in signal intensity could be regained by Muffm, as both approaches are completely compatible.
Opposed to conventional banding suppression techniques, like frequency-scouts or phase-cycling, all reconstruction methods established in this work rely on a single radial acquisition, with scan times similar to standard bSSFP scans. No prolonged measurement times occur and patient time in the scanner is kept as short as possible, improving patient comfort, susceptibility to motion or physiological noise and cost of one scan.
All in all, the frequency-modulated acquisition in combination with specializes reconstruction methods, leads to a completely new quality of images with short acquisition times.
In Magnetic Resonance Imaging (MRI), acquisition of dynamic data may be highly complex due to rapid changes occurred in the object to be imaged. For clinical diagnostic, dynamic MR images require both high spatial and temporal resolution. The speed in the acquisition is a crucial factor to capture optimally dynamics of the objects to obtain accurate diagnosis. In the 90’s, partially parallel MRI (pMRI) has been introduced to shorten scan times reducing the amount of acquired data. These approaches use multi-receiver coil arrays to acquire independently and simultaneously the data.
Reduction in the amount of acquired data results in images with aliasing artifacts. Dedicated methods as such Sensitivity Encoding (SENSE) and Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) were the basis of a series of algorithms in pMRI.
Nevertheless, pMRI methods require extra spatial or temporal information in order to optimally reconstruct the data. This information is typically obtained by an extra scan or embedded in the accelerated acquisition applying a variable density acquisition scheme.
In this work, we were able to reduce or totally eliminate the acquisition of the training data for kt-SENSE and kt-PCA algorithms obtaining accurate reconstructions with high temporal fidelity.
For dynamic data acquired in an interleaved fashion, the temporal average of accelerated data can generate an artifact-free image used to estimate the coil sensitivity maps avoiding the need of extra acquisitions. However, this temporal average contains errors from aliased components, which may lead to signal nulls along the spectra of reconstructions when methods like kt-SENSE are applied. The use of a GRAPPA filter applied to the temporal average reduces these errors and subsequently may reduce the null components in the reconstructed data. In this thesis the effect of using temporal averages from radial data was investigated. Non-periodic artifacts performed by undersampling radial data allow a more accurate estimation of the true temporal average and thereby avoiding undesirable temporal filtering in the reconstructed images. kt-SENSE exploits not only spatial coil sensitivity variations but also makes use of spatio-temporal correlations in order to separate the aliased signals. Spatio-temporal correlations in kt-SENSE are learnt using a training data set, which consists of several central k-space lines acquired in a separate scan. The scan of these extra lines results in longer acquisition times even for low resolution images. It was demonstrate that limited spatial resolution of training data set may lead to temporal filtering effects (or temporal blurring) in the reconstructed data.
In this thesis, the auto-calibration for kt-SENSE was proposed and its feasibility was tested in order to completely eliminate the acquisition of training data. The application of a prior TSENSE reconstruction produces the training data set for the kt-SENSE algorithm. These training data have full spatial resolution. Furthermore, it was demonstrated that the proposed auto-calibrating method reduces significantly temporal filtering in the reconstructed images compared to conventional kt-SENSE reconstructions employing low resolution training images. However, the performance of auto-calibrating kt-SENSE is affected by the Signal-to-Noise Ratio (SNR) of the first pass reconstructions that propagates to the final reconstructions.
Another dedicated method used in dynamic MRI applications is kt-PCA, that was first proposed for the reconstruction of MR cardiac data. In this thesis, kt-PCA was employed for the generation of spatially resolved M0, T1 and T2 maps from a single accelerated IRTrueFISP or IR-Snapshot FLASH measurement. In contrast to cardiac dynamic data, MR relaxometry experiments exhibit signal at all temporal frequencies, which makes their reconstruction more challenging. However, since relaxometry measurements can be represented by only few parameters, the use of few principal components (PC) in the kt-PCA algorithm can significantly simplify the reconstruction. Furthermore, it was found that due to high redundancy in relaxometry data, PCA can efficiently extract the required information from just a single line of training data.
It has been demonstrated in this thesis that auto-calibrating kt-SENSE is able to obtain high temporal fidelity dynamic cardiac reconstructions from moderate accelerated data avoiding the extra acquisition of training data. Additionally, kt-PCA has been proved to be a suitable method for the reconstruction of highly accelerated MR relaxometry data.
Furthermore, a single central training line is necessary to obtain accurate reconstructions. Both reconstruction methods are promising for the optimization of training data acquisition and seem to be feasible for several clinical applications.