Refine
Has Fulltext
- yes (32)
Is part of the Bibliography
- yes (32)
Year of publication
- 2022 (32) (remove)
Document Type
- Journal article (32)
Language
- English (32) (remove)
Keywords
- prostate cancer (9)
- radioligand therapy (6)
- PSMA (4)
- theranostics (4)
- PET (3)
- PET/CT (3)
- C-X-C motif chemokine receptor 4 (2)
- CXCR4 (2)
- PSMA I&T (2)
- PSMA-RADS (2)
Institute
- Klinik und Poliklinik für Nuklearmedizin (32) (remove)
EU-Project number / Contract (GA) number
- 101016923 (1)
Background:
Methylphenidate (MPH) is the first-line pharmacological treatment of attention-deficit/hyperactivity disorder (ADHD). MPH binds to the dopamine (DA) transporter (DAT), which has high density in the striatum. Assessments of the striatal dopamine transporter by single positron emission computed tomography (SPECT) in childhood and adolescent patients are rare but can provide insight on how the effects of MPH affect DAT availability. The aim of our within-subject study was to investigate the effect of MPH on DAT availability and how responsivity to MPH in DAT availability is linked to clinical symptoms and cognitive functioning.
Methods
Thirteen adolescent male patients (9–16 years) with a diagnosis of ADHD according to the DSM-IV and long-term stimulant medication (for at least 6 months) with MPH were assessed twice within 7 days using SPECT after application of I-123-β-CIT to examine DAT binding potential (DAT BP). SPECT measures took place in an on- and off-MPH status balanced for order across participants. A virtual reality continuous performance test was performed at each time point. Further clinical symptoms were assessed for baseline off-MPH.
Results
On-MPH status was associated with a highly significant change (−29.9%) of striatal DAT BP as compared to off-MPH (t = −4.12, p = 0.002). A more pronounced change in striatal DAT BP was associated with higher off-MPH attentional and externalizing symptom ratings (Pearson r = 0.68, p = 0.01). Striatal DAT BP off-MPH, but not on-MPH, was associated with higher symptom ratings (Pearson r = 0.56, p = 0.04).
Conclusion
Our findings corroborate previous reports from mainly adult samples that MPH changes striatal DAT BP availability and suggest higher off-MPH DAT BP, likely reflecting low baseline DA levels, as a marker of symptom severity.
A growing body of literature reports on the upregulation of C-X-C motif chemokine receptor 4 (CXCR4) in a variety of cancer entities, rendering this receptor as suitable target for molecular imaging and endoradiotherapy in a theranostic setting. For instance, the CXCR4-targeting positron emission tomography (PET) agent [\(^{68}\)Ga]PentixaFor has been proven useful for a comprehensive assessment of the current status quo of solid tumors, including adrenocortical carcinoma or small-cell lung cancer. In addition, [\(^{68}\)Ga]PentixaFor has also provided an excellent readout for hematological malignancies, such as multiple myeloma, marginal zone lymphoma, or mantle cell lymphoma. PET-based quantification of the CXCR4 capacities in vivo allows for selecting candidates that would be suitable for treatment using the theranostic equivalent [\(^{177}\)Lu]/[\(^{90}\)Y]PentixaTher. This CXCR4-directed theranostic concept has been used as a conditioning regimen prior to hematopoietic stem cell transplantation and to achieve sufficient anti-lymphoma/-tumor activity in particular for malignant tissues that are highly sensitive to radiation, such as the hematological system. Increasing the safety margin, pretherapeutic dosimetry is routinely performed to determine the optimal activity to enhance therapeutic efficacy and to reduce off-target adverse events. The present review will provide an overview of current applications for CXCR4-directed molecular imaging and will introduce the CXCR4-targeted theranostic concept for advanced hematological malignancies.
Background: Radiolabeled agents that are substrates for the norepinephrine transporter (NET) can be used to quantify cardiac sympathetic nervous conditions and have been demonstrated to identify high-risk congestive heart failure (HF) patients prone to arrhythmic events. We aimed to fully characterize the kinetic profile of the novel \(^{18}\)F-labeled NET probe AF78 for PET imaging of the cardiac sympathetic nervous system (SNS) among various species.
Methods: \(^{18}\)F-AF78 was compared to norepinephrine (NE) and established SNS radiotracers by employing in vitro cell assays, followed by an in vivo PET imaging approach with healthy rats, rabbits and nonhuman primates (NHPs). Additionally, chase protocols were performed in NHPs with NET inhibitor desipramine (DMI) and the NE releasing stimulator tyramine (TYR) to investigate retention kinetics in cardiac SNS.
Results: Relative to other SNS radiotracers, 18F-AF78 showed higher transport affinity via NET in a cell-based competitive uptake assay (IC\(^{50}\) 0.42 ± 0.14 µM), almost identical to that of NE (IC\(^{50}\), 0.50 ± 0.16 µM, n.s.). In rabbits and NHPs, initial cardiac uptake was significantly reduced by NET inhibition. Furthermore, cardiac tracer retention was not affected by a DMI chase protocol but was markedly reduced by intermittent TYR chase, thereby suggesting that \(^{18}\)F-AF78 is stored and can be released via the synaptic vesicular turnover process. Computational modeling hypothesized the formation of a T-shaped π-π stacking at the binding site, suggesting a rationale for the high affinity of \(^{18}\)F-AF78.
Conclusion: \(^{18}\)F-AF78 demonstrated high in vitro NET affinity and advantageous in vivo radiotracer kinetics across various species, indicating that \(^{18}\)F-AF78 is an SNS imaging agent with strong potential to guide specific interventions in cardiovascular medicine.
Aim
Recent advancements in PET technology have brought with it significant improvements in PET performance and image quality. In particular, the extension of the axial field of view of PET systems, and the introduction of semiconductor technology into the PET detector, initially for PET/MR, and more recently available long-field-of-view PET/CT systems (≥ 25 cm) have brought a step change improvement in the sensitivity of PET scanners. Given the requirement to limit paediatric doses, this increase in sensitivity is extremely welcome for the imaging of children and young people. This is even more relevant with PET/MR, where the lack of CT exposures brings further dose reduction benefits to this population. In this short article, we give some details around the benefits around new PET technology including PET/MR and its implications on the EANM paediatric dosage card.
Material and methods
Reflecting on EANM adult guidance on injected activities, and making reference to bed overlap and the concept of MBq.min bed\(^{-1}\) kg\(^{-1}\), we use published data on image quality from PET/MR systems to update the paediatric dosage card for PET/MR and extended axial field of view (≥ 25 cm) PET/CT systems. However, this communication does not cover the expansion of paediatric dosing for the half-body and total-body scanners that have recently come to market.
Results
In analogy to the existing EANM dosage card, new parameters for the EANM paediatric dosage card were developed (class B, baseline value: 10.7 MBq, minimum recommended activity 10 MBq). The recommended administered activities for the systems considered in this communication range from 11 MBq [\(^{18}\)F]FDG for a child with a weight of 3 kg to 149 MBq [\(^{18}\)F]FDG for a paediatric patient weight of 68 kg, assuming a scan of 3 min per bed position. The mean effective dose over all ages (1 year and older) is 2.85 mSv.
Conclusion
With this, recommendations for paediatric dosing are given for systems that have not been considered previously.
The use of prostate-specific membrane antigen targeted PET imaging for the evaluation of prostate cancer has increased significantly in the last couple of decades. When evaluating these imaging findings based on the PSMA reporting and data system version 1.0, which categorize lesions based on their likelihood of prostate cancer involvement, PSMA-RADS-3A lesions are commonly seen, which are indeterminate for the presence of disease. A total of 28 patients with 171 PSMA-RADS-3A lesions on \(^{18}\)F-DCFPyL PET/CT scans from June 2016 to May 2017 who had follow-up cross-sectional imaging over time were included in this study. The PSA levels of patients with PSMA-RADS-3A lesions were categorized into four groups, 0–0.2, 0.2–1, 1–2, and >2 ng/mL. The pre-operative Gleason score of these patients was categorized into two groups, Gleason score < 7 or ≥7. The median age for these patients was 72.5 years (range 59–81). The median PSA value for patients with positive lesions was significantly higher than those with negative lesions (5.8 ng/mL vs. 0.2 ng/mL, p < 0.0001). The lesion positivity rate was significantly higher in patients with PSA > 1 ng/mL (18.2% vs. 81.9%, p < 0.001). On ROC analysis, the highest classification accuracy was seen at PSA ≥ 0.6 ng/mL of 80.12% (95% CI = 73.69–86.16%), and the area under the curve was 71.32% (95% CI = 61.9–80.7%, p < 0.0001). A total of 96.4% (108/112) of patients with positive lesions and 86.4% (51/59) of patients with negative lesions had a PSMA-RADS-4/5 lymph node on the initial \(^{18}\)F-DCFPyL PET/CT scan (p = 0.02). In patients with a Gleason score ≥ 7, the presence of positive PSMA-RADS-3A lesions was higher, compared to negative PSMA-RADS-3A lesions (p = 0.049). Higher PSA levels in patients with PSMA-RADS-3A lesions can point towards the presence of true positivity. PSA levels may be considered in deciding whether to call an indeterminate lesion on PSMA PET.
Background
Fast and accurate T1ρ mapping in myocardium is still a major challenge, particularly in small animal models. The complex sequence design owing to electrocardiogram and respiratory gating leads to quantification errors in in vivo experiments, due to variations of the T\(_{1p}\) relaxation pathway. In this study, we present an improved quantification method for T\(_{1p}\) using a newly derived formalism of a T\(_{1p}\)\(^{*}\) relaxation pathway.
Methods
The new signal equation was derived by solving a recursion problem for spin-lock prepared fast gradient echo readouts. Based on Bloch simulations, we compared quantification errors using the common monoexponential model and our corrected model. The method was validated in phantom experiments and tested in vivo for myocardial T\(_{1p}\) mapping in mice. Here, the impact of the breath dependent spin recovery time T\(_{rec}\) on the quantification results was examined in detail.
Results
Simulations indicate that a correction is necessary, since systematically underestimated values are measured under in vivo conditions. In the phantom study, the mean quantification error could be reduced from − 7.4% to − 0.97%. In vivo, a correlation of uncorrected T\(_{1p}\) with the respiratory cycle was observed. Using the newly derived correction method, this correlation was significantly reduced from r = 0.708 (p < 0.001) to r = 0.204 and the standard deviation of left ventricular T\(_{1p}\) values in different animals was reduced by at least 39%.
Conclusion
The suggested quantification formalism enables fast and precise myocardial T\(_{1p}\) quantification for small animals during free breathing and can improve the comparability of study results. Our new technique offers a reasonable tool for assessing myocardial diseases, since pathologies that cause a change in heart or breathing rates do not lead to systematic misinterpretations. Besides, the derived signal equation can be used for sequence optimization or for subsequent correction of prior study results.
Purpose
T\(_{1P}\) dispersion quantification can potentially be used as a cardiac magnetic resonance index for sensitive detection of myocardial fibrosis without the need of contrast agents. However, dispersion quantification is still a major challenge, because T\(_{1P}\) mapping for different spin lock amplitudes is a very time consuming process. This study aims to develop a fast and accurate T\(_{1P}\) mapping sequence, which paves the way to cardiac T1ρ dispersion quantification within the limited measurement time of an in vivo study in small animals.
Methods
A radial spin lock sequence was developed using a Bloch simulation-optimized sampling pattern and a view-sharing method for image reconstruction. For validation, phantom measurements with a conventional sampling pattern and a gold standard sequence were compared to examine T\(_{1P}\) quantification accuracy. The in vivo validation of T\(_{1P}\) mapping was performed in N = 10 mice and in a reproduction study in a single animal, in which ten maps were acquired in direct succession. Finally, the feasibility of myocardial dispersion quantification was tested in one animal.
Results
The Bloch simulation-based sampling shows considerably higher image quality as well as improved T\(_{1P}\) quantification accuracy (+ 56%) and precision (+ 49%) compared to conventional sampling. Compared to the gold standard sequence, a mean deviation of - 0.46 ± 1.84% was observed. The in vivo measurements proved high reproducibility of myocardial T\(_{1P}\) mapping. The mean T\(_{1P}\) in the left ventricle was 39.5 ± 1.2 ms for different animals and the maximum deviation was 2.1% in the successive measurements. The myocardial T\(_{1P}\) dispersion slope, which was measured for the first time in one animal, could be determined to be 4.76 ± 0.23 ms/kHz.
Conclusion
This new and fast T\(_{1P}\) quantification technique enables high-resolution myocardial T\(_{1P}\) mapping and even dispersion quantification within the limited time of an in vivo study and could, therefore, be a reliable tool for improved tissue characterization.
Purpose
As α-emitters for radiopharmaceutical therapies are administered systemically by intravenous injection, blood will be irradiated by α-particles that induce clustered DNA double-strand breaks (DSBs). Here, we investigated the induction and repair of DSB damage in peripheral blood mononuclear cells (PBMCs) as a function of the absorbed dose to the blood following internal ex vivo irradiation with [\(^{223}\)Ra]RaCl2.
Methods
Blood samples of ten volunteers were irradiated by adding [\(^{223}\)Ra]RaCl2 solution with different activity concentrations resulting in absorbed doses to the blood of 3 mGy, 25 mGy, 50 mGy and 100 mGy. PBMCs were isolated, divided in three parts and either fixed directly (d-samples) or after 4 h or 24 h culture. After immunostaining, the induced γ-H2AX α-tracks were counted. The time-dependent decrease in α-track frequency was described with a model assuming a repair rate R and a fraction of non-repairable damage Q.
Results
For 25 mGy, 50 mGy and 100 mGy, the numbers of α-tracks were significantly increased compared to baseline at all time points. Compared to the corresponding d-samples, the α-track frequency decreased significantly after 4 h and after 24 h. The repair rates R were (0.24 ± 0.05) h−1 for 25 mGy, (0.16 ± 0.04) h−1 for 50 mGy and (0.13 ± 0.02) h−1 for 100 mGy, suggesting faster repair at lower absorbed doses, while Q-values were similar.
Conclusion
The results obtained suggest that induction and repair of the DSB damage depend on the absorbed dose to the blood. Repair rates were similar to what has been observed for irradiation with low linear energy transfer.
Introduction
In men with metastatic castration-resistant prostate cancer (mCRPC) scheduled for prostate-specific membrane antigen (PSMA)-targeted radioligand therapy (RLT), biochemical response is assessed based on repeated measurements of prostate-specific antigen (PSA) levels. We aimed to determine overall survival (OS) in patients experiencing sustained PSA increase, decrease, or fluctuations during therapy.
Materials and methods
In this bicentric study, we included 176 mCRPC patients treated with PSMA-directed RLT. PSA levels were determined using blood samples prior to the first RLT and on the admission days for the following cycles. We calculated relative changes in PSA levels compared to baseline. Kaplan–Meier curves as well as log-rank test were used to compare OS of different subgroups, including patients with sustained PSA increase, decrease, or fluctuations (defined as change after initial decrease or increase after the first cycle).
Results
Sixty-one out of one hundred seventy-six (34.7%) patients showed a sustained increase and 86/176 (48.8%) a sustained decrease in PSA levels. PSA fluctuations were observed in the remaining 29/176 (16.5%). In this subgroup, 22/29 experienced initial PSA decrease followed by an increase (7/29, initial increase followed by a decrease). Median OS of patients with sustained decrease in PSA levels was significantly longer when compared to patients with sustained increase of PSA levels (19 vs. 8 months; HR 0.35, 95% CI 0.22–0.56; P < 0.001). Patients with PSA fluctuations showed a significantly longer median OS compared to patients with sustained increase of PSA levels (18 vs. 8 months; HR 0.49, 95% CI 0.30–0.80; P < 0.01), but no significant difference relative to men with sustained PSA decrease (18 vs. 19 months; HR 1.4, 95% CI 0.78–2.49; P = 0.20). In addition, in men experiencing PSA fluctuations, median OS did not differ significantly between patients with initial decrease or initial increase of tumor marker levels (16 vs. 18 months; HR 1.2, 95% CI 0.38–4.05; P = 0.68).
Conclusion
Initial increase or decrease of PSA levels is sustained in the majority of patients undergoing RLT. Sustained PSA decrease was linked to prolonged survival and men with PSA fluctuations under treatment experienced comparable survival benefits. As such, transient tumor marker oscillations under RLT should rather not lead to treatment discontinuation, especially in the absence of radiological progression.
Simple Summary
The calculation of PSMA-positive tumor volume (PSMA-TV) of the whole body from PSMA PET scans for response evaluation remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative tumor lesions. Changes in the whole-body PSMA-TV of 65 patients were comparable to the changes in PSMA-TV after including only the ten largest lesions. Moreover, changes in PSMA-TV correlated well with changes in PSA levels, as did the changes in PSMA-TV with the reduced number of lesions. We conclude that a response assessment using PSMA-TV with a reduced number of lesions is feasible and could lead to a simplified process for evaluating PSMA PET/CT.
Abstract
(1) Background: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET)-derived parameters, such as the commonly used standardized uptake value (SUV) and PSMA-positive tumor volume (PSMA-TV), have been proposed for response assessment in metastatic prostate cancer (PCa) patients. However, the calculation of whole-body PSMA-TV remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative lesions. (2) Methods: Sixty-five patients classified into different disease stages were assessed by PSMA PET/CT for staging and restaging after therapy. Whole-body PSMA-TV and whole-body SUV\(_{max}\) were calculated. We then repeated this calculation only including the five or ten hottest or largest lesions. The corresponding serum levels of prostate-specific antigen (PSA) were also determined. The derived delta between baseline and follow-up values provided the following parameters: ΔSUV\(_{maxall}\), ΔSUV\(_{max10}\), ΔSUV\(_{max5}\), ΔPSMA-TV\(_{all}\), ΔPSMA-TV\(_{10}\), ΔPSMA-TV\(_{5}\), ΔPSA. Finally, we compared the findings from our whole-body segmentation with the results from our keyhole approach (focusing on a limited number of lesions) and correlated all values with the biochemical response (ΔPSA). (3) Results: Among patients with metastatic hormone-sensitive PCa (mHSPC), none showed a relevant deviation for ΔSUV\(_{max10}\)/ΔSUV\(_{max5}\) or ΔPSMA-TV\(_{10}\)/ΔPSMA-TV\(_{5}\) compared to ΔSUV\(_{maxall}\) and ΔPSMA-TV\(_{all}\). For patients treated with taxanes, up to 6/21 (28.6%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only up to 2/21 (9.5%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). For patients treated with radioligand therapy (RLT), up to 5/28 (17.9%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only 1/28 (3.6%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). The highest correlations with ΔPSA were found for ΔPSMA-TV\(_{all}\) (r ≥ 0.59, p ≤ 0.01), followed by ΔPSMA-TV\(_{10}\) (r ≥ 0.57, p ≤ 0.01) and ΔPSMA-TV\(_{5}\) (r ≥ 0.53, p ≤ 0.02) in all cohorts. ΔPSA only correlated with ΔSUV\(_{maxall}\) (r = 0.60, p = 0.02) and with ΔSUV\(_{max10}\) (r = 0.53, p = 0.03) in the mHSPC cohort, as well as with ΔSUV\(_{maxall}\) (r = 0.51, p = 0.01) in the RLT cohort. (4) Conclusion: Response assessment using PSMA-TV with a reduced number of lesions is feasible, and may allow for a simplified evaluation process for PSMA PET/CT.