Refine
Has Fulltext
- yes (2)
Is part of the Bibliography
- yes (2)
Year of publication
- 2011 (2) (remove)
Document Type
- Doctoral Thesis (2)
Language
- English (2) (remove)
Keywords
- Optimierung (2) (remove)
Institute
In the future Internet, the people-centric communication paradigm will be complemented by a ubiquitous communication among people and devices, or even a communication between devices. This comes along with the need for a more flexible, cheap, widely available Internet access. Two types of wireless networks are considered most appropriate for attaining those goals. While wireless sensor networks (WSNs) enhance the Internet’s reach by providing data about the properties of the environment, wireless mesh networks (WMNs) extend the Internet access possibilities beyond the wired backbone. This monograph contains four chapters which present modeling and optimization methods for WSNs and WMNs. Minimizing energy consumptions is the most important goal of WSN optimization and the literature consequently provides countless energy consumption models. The first part of the monograph studies to what extent the used energy consumption model influences the outcome of analytical WSN optimizations. These considerations enable the second contribution, namely overcoming the problems on the way to a standardized energy-efficient WSN communication stack based on IEEE 802.15.4 and ZigBee. For WMNs both problems are of minor interest whereas the network performance has a higher weight. The third part of the work, therefore, presents algorithms for calculating the max-min fair network throughput in WMNs with multiple link rates and Internet gateway. The last contribution of the monograph investigates the impact of the LRA concept which proposes to systematically assign more robust link rates than actually necessary, thereby allowing to exploit the trade-off between spatial reuse and per-link throughput. A systematical study shows that a network-wide slightly more conservative LRA than necessary increases the throughput of a WMN where max-min fairness is guaranteed. It moreover turns out that LRA is suitable for increasing the performance of a contention-based WMN and is a valuable optimization tool.
Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contrast, especially of biological tissue. The main disadvantages of MRI, compared to other widespread imaging modalities like computed tomography (CT), are long measurement times and the directly resulting high costs. In the first part of this work, a new technique for accelerated MRI parameter mapping using a radial IR TrueFISP sequence is presented. IR TrueFISP is a very fast method for the simultaneous quantification of proton density, the longitudinal relaxation time T1, and the transverse relaxation time T2. Chapter 2 presents speed improvements to the original IR TrueFISP method. Using a radial view-sharing technique, it was possible to obtain a full set of relaxometry data in under 6 s per slice. Furthermore, chapter 3 presents the investigation and correction of two major sources of error of the IR TrueFISP method, namely magnetization transfer and imperfect slice profiles. In the second part of this work, a new MRI thermometry method is presented that can be used in MRI-safety investigations of medical implants, e.g. cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). One of the major safety risks associated with MRI examinations of pacemaker and ICD patients is RF induced heating of the pacing electrodes. The design of MRI-safe (or MRI-conditional) pacing electrodes requires elaborate testing. In a first step, many different electrode shapes, electrode positions and sequence parameters are tested in a gel phantom with its geometry and conductivity matched to a human body. The resulting temperature increase is typically observed using temperature probes that are placed at various positions in the gel phantom. An alternative to this local thermometry approach is to use MRI for the temperature measurement. Chapter 5 describes a new approach for MRI thermometry that allows MRI thermometry during RF heating caused by the MRI sequence itself. Specifically, a proton resonance frequency (PRF) shift MRI thermometry method was combined with an MR heating sequence. The method was validated in a gel phantom, with a copper wire serving as a simple model for a medical implant.