High convection volume in online post-dilution haemodiafiltration: relevance, safety and costs
(2015)
Increasing evidence suggests that treatment with online post-dilution haemodiafiltration (HDF) improves clinical outcome in patients with end-stage kidney disease, if compared with haemodialysis (HD). Although the primary analyses of three large randomized controlled trials (RCTs) showed inconclusive results, post hoc analyses of these and previous observational studies comparing online post-dilution HDF with HD showed that the risk of overall and cardiovascular mortality is lowest in patients who are treated with high-volume HDF. As such, the magnitude of the convection volume seems crucial and can be considered as the ‘dose’ of HDF. In this narrative review, the relevance of high convection volume in online post-dilution HDF is discussed. In addition, we briefly touch upon some safety and cost issues.
Background
In patients undergoing maintenance hemodialysis (HD), increased levels of circulating fibroblast growth factor-23 (FGF-23) are independently associated with cardiovascular events and mortality. Interventional strategies aiming to reduce levels of FGF-23 in HD patients are of particular interest. The purpose of the current study was to compare the impact of high-flux versus low-flux HD on circulating FGF-23 levels.
Methods
We conducted a post-hoc analysis of the MINOXIS study, including 127 dialysis patients randomized to low-flux (n = 62) and high-flux (n = 65) HD for 52 weeks. Patients with valid measures for FGF-23 investigated baseline and after 52 weeks were included.
Results
Compared to baseline, a significant increase in FGF-23 levels after one year of low-flux HD was observed (Delta plasma FGF-23: +4026 RU/ml; p < 0.001). In contrast, FGF-23 levels remained stable in the high flux group (Delta plasma FGF-23: +373 RU/ml, p = 0.70). The adjusted difference of the absolute change in FGF-23 levels between the two treatment groups was statistically significant (p < 0.01).
Conclusions
Over a period of 12 months, high-flux HD was associated with stable FGF-23 levels, whereas the low-flux HD group showed an increase of FGF-23. However, the implications of the different FGF 23 time-trends in patients on high flux dialysis, as compared to the control group, remain to be explored in specifically designed clinical trials.