Refine
Year of publication
- 2019 (781) (remove)
Document Type
- Journal article (572)
- Doctoral Thesis (163)
- Book article / Book chapter (23)
- Preprint (19)
- Conference Proceeding (1)
- Other (1)
- Report (1)
- Working Paper (1)
Language
- English (781) (remove)
Keywords
- Animal Studies (24)
- Cultural Animal Studies (24)
- Cultural Studies (24)
- Ecocriticism (24)
- Environmental Humanities (24)
- Human-Animal Studies (24)
- Literary Studies (24)
- boron (11)
- apoptosis (9)
- cancer (7)
Institute
- Theodor-Boveri-Institut für Biowissenschaften (110)
- Graduate School of Life Sciences (51)
- Physikalisches Institut (48)
- Medizinische Klinik und Poliklinik II (37)
- Institut für Psychologie (35)
- Neurologische Klinik und Poliklinik (34)
- Medizinische Klinik und Poliklinik I (31)
- Institut für Anorganische Chemie (30)
- Institut für Organische Chemie (28)
- Klinik und Poliklinik für Psychiatrie, Psychosomatik und Psychotherapie (25)
Schriftenreihe
Sonstige beteiligte Institutionen
- VolkswagenStiftung (24)
- Johns Hopkins School of Medicine (2)
- Bio-Imaging Center Würzburg (1)
- CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - the development agency of the Brazilian Federal Government (1)
- Center for Nanosystems Chemistry (CNC), Universität Würzburg (1)
- DAAD - Deutscher Akademischer Austauschdienst (1)
- Department of Hematology and Oncology, Sana Hospital Hof, Hof, Germany (1)
- Department of Laboratory Medicine and Medicine Huddinge, Karolinska Institutet and University Hospital, Stockholm, Sweden (1)
- Department of Medicine A, University Hospital of Münster, Münster, Germany (1)
- Ernst Strüngmann Institute for Neuroscience in Cooperation with Max Planck Society (ESI) (1)
ResearcherID
- B-4606-2017 (1)
Background
Airway management is crucial and, probably, even the most important key competence in anaesthesiology, which directly influences patient safety and outcome. However, high-quality research is rarely published and studies usually have different primary or secondary endpoints which impedes clear unbiased comparisons between studies. The aim of the present study was to gather and analyse primary and secondary endpoints in video laryngoscopy studies being published over the last ten years and to create a core set of uniform or homogeneous outcomes (COS).
Methods
Retrospective analysis. Data were identified by using MEDLINE® database and the terms “video laryngoscopy” and “video laryngoscope” limited to the years 2007 to 2017. A total of 3351 studies were identified by the applied search strategy in PubMed. Papers were screened by two anaesthesiologists independently to identify study endpoints. The DELPHI method was used for consensus finding.
Results
In the 372 studies analysed and included, 49 different outcome categories/columns were reported. The items “time to intubation” (65.86%), “laryngeal view grade” (44.89%), “successful intubation rate” (36.56%), “number of intubation attempts” (23.39%), “complications” (21.24%), and “successful first-pass intubation rate” (19.09%) were reported most frequently. A total of 19 specific parameters is recommended.
Conclusions
In recent video laryngoscopy studies, many different and inhomogeneous parameters were used as outcome descriptors/endpoints. Based on these findings, we recommend that 19 specific parameters (e.g., “time to intubation” (inserting the laryngoscope to first ventilation), “laryngeal view grade” (C&L and POGO), “successful intubation rate”, etc.) should be used in coming research to facilitate future comparisons of video laryngoscopy studies.
Background
The heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible.
Methods
We included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure.
Results
H/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R\(^2\) = 0.99, p < 0.001 and R\(^2\) = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 × H/M-ME + 0.63, R\(^2\) = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 ± 0.04; mean relative absolute error 3.2 ± 2.6%).
Conclusions
The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions.
Background
Increasing bacterial resistance to antibiotics is a serious problem worldwide. We sought to record the acquisition of antibiotic-resistant Escherichia coli (E. coli) in healthy infants in Northern Thailand and investigated potential determinants.
Methods
Stool samples from 142 infants after birth, at ages 2wk, 2mo, 4 to 6mo, and 1y, and parent stool samples were screened for E. coli resistance to tetracycline, ampicillin, co-trimoxazole, and cefazoline by culture, and isolates were further investigated for multiresistance by disc diffusion method. Pulsed-field gel electrophoresis was performed to identify persistent and transmitted strains. Genetic comparison of resistant and transmitted strains was done by multilocus sequence typing (MLST) and strains were further investigated for extra- and intra-intestinal virulence factors by multiplex PCR.
Results
Forty-seven (33%) neonatal meconium samples contained resistant E. coli. Prevalence increased continuously: After 1y, resistance proportion (tetracycline 80%, ampicillin 72%, co-trimoxazole 66%, cefazoline 35%) almost matched those in parents. In 8 infants (6%), identical E. coli strains were found in at least 3 sampling time points (suggesting persistence). Transmission of resistant E. coli from parents to child was observed in only 8 families. MLST showed high diversity. We could not identify any virulence genes or factors associated with persistence, or transmission of resistant E. coli. Full-term, vaginal birth and birth in rural hospital were identified as risk factors for early childhood colonization with resistant E. coli.
Conclusion
One third of healthy Thai neonates harboured antibiotic-resistant E. coli in meconium. The proportion of resistant E. coli increased during the first year of life almost reaching the value in adults. We hypothesize that enhancement of infection control measures and cautious use of antibiotics may help to control further increase of resistance.
Background
Colonization with Staphylococcus aureus has been identified as a risk for subsequent occurrence of infection. This study investigated the relationship between S. aureus colonization of patients and healthcare workers (HCWs), and subsequent surgical site infections (SSI).
Methods
Between December 2014 and September 2015, a total of 930 patients and 143 HCWs were enrolled from the Bugando Medical Centre and Sekou Toure hospital in Mwanza, Tanzania. On admission and discharge nasal swabs, with an additional of wound swab for those who developed SSI were collected from patients whereas HCWs were swabbed once. Identification and antimicrobial susceptibility testing were done by VITEK-MS and VITEK-2, respectively. Detection of Panton Valentine leukocidin (PVL) and mecA genes was done by PCR. S. aureus isolates were further characterized by spa typing and Multi-Locus Sequence Typing (MLST).
Results
Among 930 patients screened for S. aureus on admission, 129 (13.9%) were positive of which 5.4% (7/129) were methicillin-resistant S. aureus (MRSA). Amongst 363 patients rescreened on discharge, 301 patients had been tested negative on admission of whom 29 (9.6%) turned positive after their hospital stay. Three (10.3%) of the 29 acquired S. aureus were MRSA. Inducible Clindamycin resistance occurred more often among acquired S. aureus isolates than among isolates from admission [34.5% (10/29) vs. 17.1% (22/129), P = 0.018]. S. aureus contributed to 21.1% (n = 12) of the 57 cases of investigated SSIs among 536 patients followed. Seven out of eight S. aureus carriage/infection pairs had the same spa and sequence types. The previously reported dominant PVL-positive ST88 MRSA strain with spa type t690 was detected in patients and HCW.
Conclusion
A significant proportion of patients acquired S. aureus during hospitalization. The finding of more than 90% of S. aureus SSI to be of endogenous source underscores the need of improving infection prevention and control measures including screening and decolonization of high risk patients.
In response to the 2013 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) study was launched, as an international collaboration hosted by CERN. This study covers a highest-luminosity high-energy lepton collider (FCC-ee) and an energy-frontier hadron collider (FCC-hh), which could, successively, be installed in the same 100 km tunnel. The scientific capabilities of the integrated FCC programme would serve the worldwide community throughout the 21st century. The FCC study also investigates an LHC energy upgrade, using FCC-hh technology. This document constitutes the second volume of the FCC Conceptual Design Report, devoted to the electron-positron collider FCC-ee. After summarizing the physics discovery opportunities, it presents the accelerator design, performance reach, a staged operation scenario, the underlying technologies, civil engineering, technical infrastructure, and an implementation plan. FCC-ee can be built with today's technology. Most of the FCC-ee infrastructure could be reused for FCC-hh. Combining concepts from past and present lepton colliders and adding a few novel elements, the FCC-ee design promises outstandingly high luminosity. This will make the FCC-ee a unique precision instrument to study the heaviest known particles (Z, W and H bosons and the top quark), offering great direct and indirect sensitivity to new physics.
We review the physics opportunities of the Future Circular Collider, covering its e(+)e(-), pp, ep and heavy ion programmes. We describe the measurement capabilities of each FCC component, addressing the study of electroweak, Higgs and strong interactions, the top quark and flavour, as well as phenomena beyond the Standard Model. We highlight the synergy and complementarity of the different colliders, which will contribute to a uniquely coherent and ambitious research programme, providing an unmatchable combination of precision and sensitivity to new physics.
In response to the 2013 Update of the European Strategy for Particle Physics (EPPSU), the Future Circular Collider (FCC) study was launched as a world-wide international collaboration hosted by CERN. The FCC study covered an energy-frontier hadron collider (FCC-hh), a highest-luminosity high-energy lepton collider (FCC-ee), the corresponding 100 km tunnel infrastructure, as well as the physics opportunities of these two colliders, and a high-energy LHC, based on FCC-hh technology. This document constitutes the third volume of the FCC Conceptual Design Report, devoted to the hadron collider FCC-hh. It summarizes the FCC-hh physics discovery opportunities, presents the FCC-hh accelerator design, performance reach, and staged operation plan, discusses the underlying technologies, the civil engineering and technical infrastructure, and also sketches a possible implementation. Combining ingredients from the Large Hadron Collider (LHC), the high-luminosity LHC upgrade and adding novel technologies and approaches, the FCC-hh design aims at significantly extending the energy frontier to 100 TeV. Its unprecedented centre-of-mass collision energy will make the FCC-hh a unique instrument to explore physics beyond the Standard Model, offering great direct sensitivity to new physics and discoveries.
In response to the 2013 Update of the European Strategy for Particle Physics (EPPSU), the Future Circular Collider (FCC) study was launched as a world-wide international collaboration hosted by CERN. The FCC study covered an energy-frontier hadron collider (FCC-hh), a highest-luminosity high-energy lepton collider (FCC-ee), the corresponding 100km tunnel infrastructure, as well as the physics opportunities of these two colliders, and a high-energy LHC, based on FCC-hh technology. This document constitutes the third volume of the FCC Conceptual Design Report, devoted to the hadron collider FCC-hh. It summarizes the FCC-hh physics discovery opportunities, presents the FCC-hh accelerator design, performance reach, and staged operation plan, discusses the underlying technologies, the civil engineering and technical infrastructure, and also sketches a possible implementation. Combining ingredients from the Large Hadron Collider (LHC), the high-luminosity LHC upgrade and adding novel technologies and approaches, the FCC-hh design aims at significantly extending the energy frontier to 100TeV. Its unprecedented centre of-mass collision energy will make the FCC-hh a unique instrument to explore physics beyond the Standard Model, offering great direct sensitivity to new physics and discoveries.
Narrow resonances decaying into WW, WZ or ZZ boson pairs are searched for in 139 fb(-1) of proton-proton collision data at a centre-of-mass energy of root s = 13TeV recorded with the ATLAS detector at the Large Hadron Collider from 2015 to 2018. The diboson system is reconstructed using pairs of high transverse momentum, large-radius jets. These jets are built from a combination of calorimeter- and tracker-inputs compatible with the hadronic decay of a boosted W or Z boson, using jet mass and substructure properties. The search is performed for diboson resonances with masses greater than 1.3TeV. No significant deviations from the background expectations are observed. Exclusion limits at the 95% confidence level are set on the production cross-section times branching ratio into dibosons for resonances in a range of theories beyond the Standard Model, with the highest excluded mass of a new gauge boson at 3.8TeV in the context of mass-degenerate resonances that couple predominantly to gauge bosons.
This paper describes a study of techniques for identifying Higgs bosons at high transverse momenta decaying into bottom-quark pairs, H -> b (b) over bar, for proton-proton collision data collected by the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy root s = 13 TeV. These decays are reconstructed from calorimeter jets found with the anti-k(t) R = 1.0 jet algorithm. To tag Higgs bosons, a combination of requirements is used: b-tagging of R = 0.2 track-jets matched to the large-R calorimeter jet, and requirements on the jet mass and other jet substructure variables. The Higgs boson tagging efficiency and corresponding multijet and hadronic top-quark background rejections are evaluated using Monte Carlo simulation. Several benchmark tagging selections are defined for different signal efficiency targets. The modelling of the relevant input distributions used to tag Higgs bosons is studied in 36 fb(-1) of data collected in 2015 and 2016 using g -> b (b) over bar and Z(-> b (b) over bar)gamma event selections in data. Both processes are found to be well modelled within the statistical and systematic uncertainties.