In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDI\(_{vol}\) 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1–3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732–0.848; p < 0.001) and fracture assessability (0.880; 0.842–0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0–3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise.
The calcaneal beak fracture is a rare avulsion fracture of the tuber calcanei characterized by a solid bony fragment at the Achilles tendon insertion. Treatment usually requires osteosynthesis. However, lack of biomechanical understanding of the ideal fixation technique persists. A beak fracture was simulated in synthetic bones and assigned to five different groups of fixation: A) 6.5-mm partial threaded cannulated screws, B) 4.0-mm partial threaded cannulated screws, C) 5.0-mm headless cannulated compression screws, D) 2.3-mm locking plate, and E) 2.8-mm locking plate. Different traction force levels were applied through an Achilles tendon surrogate in a material-testing machine on all stabilized synthetic bones. Outcome measures were peak-to-peak displacement, total displacement, plastic deformation, stiffness, visual-fracture-line displacement, and mode of implant failure. The 2.3- and 2.8-mm plating groups showed a high drop-out rate at 100 N tension force and failed under higher tension levels of 200 N. The fracture fixation using 4.0-mm partial threaded screws showed a significantly higher repair strength and was able to withhold cyclic loading up to 300 N. The lowest peak-to-peak displacement and the highest load-to-failure and stiffness were provided by fracture fixation using 6.5-mm partial threaded cannulated screws or 5.0-mm headless cannulated compression screws. As anticipated, large 6.5-mm screw diameters provide the best biomechanical fixation. Surprisingly, the 5.0-mm headless cannulated compression screws yield reliable stability despite the absent screw head and washer. When such large screws cannot be applied, 4.0-mm screws also allow reasonable fixation strength. Plate fixation should be implemented with precaution and in combination with a restrictive postoperative motion protocol. Finally, clinical cases about the surgical application and recovery are included.
Die Ellenbogenfraktur ist eine häufige Fraktur der oberen Extremität. Um die Funktion des Ellenbogengelenks zu erhalten, sind eine gute Reposition und eine stabile Osteosynthese, sowie eine frühfunktionelle Nachbehandlung der Olekranonfraktur erforderlich.
Zur Versorgung von komplexen Frakturen des Olekranons mit mehreren Fragmenten stehen prinzipiell zwei Osteosyntheseverfahren zur Verfügung. Die dorsale Plattenosteosynthese ist ein schon länger zur Verfügung stehendes Verfahren. Bei der klinischen Anwendung treten jedoch immer wieder Weichteilirritationen durch die dorsale Lage der recht massiven Platte auf. Seit einigen Jahren existiert eine weitere Osteosynthese, bei der zwei flache laterale Olekranonplatten verwendet werden. Durch die Positionierung sollen Wundheilungsstörungen reduziert werden. Ziel dieser Arbeit war die Entwicklung eines biomechanischen Testmodells und die Stabilitätsprüfung der zwei Verfahren zur Plattenosteosynthese bei mehrfragmentären Olekranonfrakturen in einem klinisch relevanten Belastungsumfang.
Die zwei seitlich angebrachten Olekranon Zwillingsplatten stellen eine gute Alternative zu der singulären dorsalen LCP- Olekranonplatte dar, da sie weniger Weichteilirritationen verursachen und im biomechanischen Model unter hoher Belastung eine vergleichbare Stabilität gewährleisten.
The subject of this thesis is the rigorous passage from discrete systems to continuum models via variational methods.
The first part of this work studies a discrete model describing a one-dimensional chain of atoms with finite range interactions of Lennard-Jones type. We derive an expansion of the ground state energy using \(\Gamma\)-convergence. In particular, we show that a variant of the Cauchy-Born rule holds true for the model under consideration. We exploit this observation to derive boundary layer energies due to asymmetries of the lattice at the boundary or at cracks of the specimen. Hereby we extend several results obtained previously for models involving only nearest and next-to-nearest neighbour interactions by Braides and Cicalese and Scardia, Schlömerkemper and Zanini.
The second part of this thesis is devoted to the analysis of a quasi-continuum (QC) method. To this end, we consider the discrete model studied in the first part of this thesis as the fully atomistic model problem and construct an approximation based on a QC method. We show that in an elastic setting the expansion by \(\Gamma\)-convergence of the fully atomistic energy and its QC approximation coincide. In the case of fracture, we show that this is not true in general. In the case of only nearest and next-to-nearest neighbour interactions, we give sufficient conditions on the QC approximation such that, also in case of fracture, the minimal energies of the fully atomistic energy and its approximation coincide in the limit.
Introduction
Proximal ulna fractures are common in orthopaedic surgery. Comminuted fractures require a high primary stability by the osteosynthesis, to allow an early functional rehabilitation as fast as possible, to reduce long-term limitations of range of motion. Classical dorsal plating is related to wound healing problems due to the prominence of the implant. New low-profile double plates are available addressing the soft tissue problems by positioning the plates at the medial and lateral side. This study analysed whether, under high loading conditions, these new double plates provide an equivalent stability as compared to the rigid olecranon locking compression plate (LCP).
Materials and methods
In Sawbones, Mayo Type IIB fractures were simulated and stabilized by plate osteosyntheses: In group one, two low-profile plates were placed. In group two, a single dorsal plate (LCP) was used. The bones was than cyclically loaded simulating flexion grades of 0°, 30°, 60° and 90° of the elbow joint with increasing tension forces (150 , 150 , 300 and 500 N). The displacement and fracture gap movement were recorded. In the end, in load-to-failure tests, load at failure and mode of failure were determined.
Results
No significant differences were found for the displacement and fracture gap widening during cyclic loading. Under maximum loading, the double plates revealed a comparable load at failure like the single dorsal plate (LCP). The double plates failed with a proximal screw pull-out of the plate, whereas in the LCP group, in 10 out of 12 specimens the mode of failure was a diaphyseal shaft fracture at the distal plate peak.
Conclusion
Biomechanically, the double plates are a good alternative to the dorsal LCP providing a high stability under high loading conditions and, at the same, time reducing the soft tissue irritation by a lateral plate position.
Background
Laxatives are among the most widely used over-the-counter medications in the United States but studies examining their potential hazardous side effects are sparse. Associations between laxative use and risk for fractures and change in bone mineral density [BMD] have not previously been investigated.
Methods
This prospective analysis included 161,808 postmenopausal women (8907 users and 151,497 nonusers of laxatives) enrolled in the WHI Observational Study and Clinical Trials. Women were recruited from October 1, 1993, to December 31, 1998, at 40 clinical centers in the United States and were eligible if they were 50 to 79 years old and were postmenopausal at the time of enrollment. Medication inventories were obtained during in-person interviews at baseline and at the 3-year follow-up visit on everyone. Data on self-reported falls (≥2), fractures (hip and total fractures) were used. BMD was determined at baseline and year 3 at 3 of the 40 clinical centers of the WHI.
Results
Age-adjusted rates of hip fractures and total fractures, but not for falls were similar between laxative users and non-users regardless of duration of laxative use. The multivariate-adjusted hazard ratios for any laxative use were 1.06 (95% confidence interval [CI], 1.03-1.10) for falls, 1.02 (95% CI, 0.85-1.22) for hip fractures and 1.01 (95% CI, 0.96-1.07) for total fractures. The BMD levels did not statistically differ between laxative users and nonusers at any skeletal site after 3-years intake.
Conclusion
These findings support a modest association between laxative use and increase in the risk of falls but not for fractures. Its use did not decrease bone mineral density levels in postmenopausal women. Maintaining physical functioning, and providing adequate treatment of comorbidities that predispose individuals for falls should be considered as first measures to avoid potential negative consequences associated with laxative use.
Intra- and interobserver reliability of glenoid fracture classifications by Ideberg, Euler and AO
(2018)
Background:
Representing 3%-5% of shoulder girdle injuries scapula fractures are rare. Furthermore, approximately 1% of scapula fractures are intraarticularfractures of the glenoid fossa. Because of uncertain fracture morphology and limited experience, the treatment of glenoid fossa fractures is difficult. The glenoid fracture classification by Ideberg (1984) and Euler (1996) is still commonly used in literature. In 2013 a new glenoid fracture classification was introduced by the AO. The purpose of this study was to examine the new AO classification in clinical practice in comparison with the classifications by Ideberg and Euler.
Methods:
In total CT images of 84 patients with glenoid fossa fractures from 2005 to 2018 were included. Parasagittal, paracoronary and axial reconstructions were examined according to the classifications of Ideberg, Euler and the AO by 3 investigators (orthopedic surgeon, radiologist, student of medicine) at three individual time settings. Inter- and intraobserver reliability of the three classification systems were ascertained by computing Inter- and Intraclass (ICCs) correlation coefficients using Spearman's rank correlation coefficient, 95%-confidence intervals as well as F-tests for correlation coefficients.
Results:
Inter- and intraobserver reliability for the AO classification showed a perspicuous coherence (R = 0.74 and R = 0.79). Low to moderate intraobserver reliability for Ideberg (R = 0.46) and Euler classification (R = 0.41) was found. Furthermore, data show a low Interobserver reliability for both Ideberg and Euler classification (R < 0.2). Both the Inter- and Intraclass reliability using AO is significantly higher than those using Ideberg and Euler (p < 0.05). Using the new AO classification, it was possible to find a proper class for every glenoid fossa fracture. On average, according to Euler classification 10 of 84 fractures were not classifiable whereas to Ideberg classification 21 of 84 fractures were not classifiable.
Conclusion:
The new AO classification system introduced 2013 facilitates reliable grading of glenoid fossa fractures with high inter- and intraobserver reliability in 84 patients using CT images. It should possibly be applied in order to enable a valid, reliable and consistent academic description of glenoid fossa fractures. The established classifications by Euler and Ideberg are not capable of providing a similar reliability.
Background
Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice.
Methods
Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers.
Results
In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676–0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525–0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771–0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692–0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912).
Conclusions
The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.
Ziel: Darstellung der verschiedenen Ellenbogenfrakturen im Kindesalter mit Ausnahme der suprakondylären Humerusfraktur bezüglich ihrer Häufigkeit, Therapiemöglichkeiten und typischen Komplikationen. Weiterhin Beurteilung der verschiedenen Therapiestrategien der einzelnen Frakturtypen unter Berücksichtigung der Schwere des Primärtraumas und der vorhandenen Begleitver-letzungen. Material und Methoden: Erfassung aller 73 kindlichen Patienten, die von 1984-1993 an der Chirurgischen Universitätsklinik mit Ellenbogenfrakturen ausgenommen der suprakondylären Humerusfraktur behandelt worden sind anhand der Krankenunterlagen und Bewertung der Ergebnisse der Nachuntersuchung von 48 Patienten 3-14 Jahre nach dem Unfall anhand der Klassifikation nach MORGER, welche auf dem Ausmaß von Bewegungseinschränkungen nach der Neutral-Null-Methode und Achsabweichungen der Ellenbogenachse in Grad basiert. Ergebnis: Insgesamt fand sich 21 mal ein ideales, 22 mal ein gutes, 1 mal ein befriedigendes und 4 mal ein schlechtes Ergebnis bei der Nachuntersuchung. Die häufigste Fraktur war die des Condylus radialis, gefolgt von der Epicondylus ulnaris Fraktur und der Fraktur des proximalen Radiusendes. Die übrigen Frakturen kamen nur selten vor. Bei den Condylus radialis Frakturen stellten sich Kompressionsosteosythesetechniken im Hinblick auf zu vermeidende Wachstumsstörungen als vorteilhaft gegenüber reinen Spickdrahtosteosynthesen dar. Bei den übrigen Frakturen konnte kein Osteosyntheseverfahren als eindeutig geeigneter beurteilt werden. Wichtig erscheint, dass bei Condylus radialis Frakturen und Epicondylus ulnaris Frakturen beim Vorliegen einer Fragmentdislokation und bei Frakturen des proximalen Radiusendes ab einem bestimmten Dislokationsgrad operative Therapieverfahren zur Anwendung kommen sollten. Insgesamt korreliert das Ergebnis der Nachuntersuchungen in erster Linie in entscheidendem Ausmaß mit der Schwere der Primärverletzung. Die Folgen starker Traumatisierungen des Kapsel-Band-Apparates stellten sich hierbei als besonders ungünstig und therapeutisch schwierig zu beeinflussend dar.
This predefined analysis of the European Forsteo Observational Study (EFOS) aimed to describe clinical fracture incidence, back pain, and health-related quality of life (HRQoL) during 18 months of teriparatide treatment and 18 months post-teriparatide in the subgroup of 589 postmenopausal women with osteoporosis aged ≥75 years. Data on clinical fractures, back pain (visual analogue scale, VAS), and HRQoL (EQ-5D) were collected over 36 months. Fracture data were summarized in 6-month intervals and analyzed using logistic regression with repeated measures. A repeated-measures model analyzed changes from baseline in back pain VAS and EQ-VAS. During the 36-month observation period, 87 (14.8 %) women aged ≥75 years sustained a total of 111 new fractures: 37 (33.3 %) vertebral fractures and 74 (66.7 %) nonvertebral fractures. Adjusted odds of fracture was decreased by 80 % in the 30 to <36–month interval compared with the first 6-month interval (P < 0.009). Although the older subgroup had higher back pain scores and poorer HRQoL at baseline than the younger subgroup, both age groups showed significant reductions in back pain and improvements in HRQoL postbaseline. In conclusion, women aged ≥75 years with severe postmenopausal osteoporosis treated with teriparatide in normal clinical practice showed a reduced clinical fracture incidence by 30 months compared with baseline. An improvement in HRQoL and, possibly, an early and significant reduction in back pain were also observed, which lasted for at least 18 months after teriparatide discontinuation when patients were taking other osteoporosis medication. The results should be interpreted in the context of an uncontrolled observational study.