Refine
Is part of the Bibliography
- yes (240)
Year of publication
Document Type
- Journal article (127)
- Doctoral Thesis (112)
- Preprint (1)
Keywords
- MRI (21)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Herzinfarkt (7)
- Kernspintomografie (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
- Herz (5)
- Herzmuskel (5)
- Kernspintomographie (5)
- Perfusion (5)
- endovascular (5)
- myocardial infarction (5)
- CT angiography (4)
- Fabry-Krankheit (4)
- Hirntumor (4)
- Lunge (4)
- Magnetresonanztomographie (4)
- Ultraschall (4)
- deep learning (4)
- late enhancement (4)
- lung (4)
- multiple myeloma (4)
- rotator cuff (4)
- ultrasound (4)
- Funktionelle NMR-Tomographie (3)
- Harmonic Imaging (3)
- Herzstoffwechsel (3)
- Interventionsradiologie (3)
- Kinder (3)
- Kontrastmittel (3)
- Koronarperfusion (3)
- MR-Spektroskopie (3)
- Mammographie (3)
- Medizin (3)
- NMR-Bildgebung (3)
- Polytrauma (3)
- Pädiatrie (3)
- Radiologie (3)
- SLOOP (3)
- Spektroskopie (3)
- arthrography (3)
- cardiac magnetic resonance imaging (3)
- children (3)
- computed tomography (3)
- diagnosis (3)
- giant cell arteritis (3)
- heart (3)
- liver (3)
- machine learning (3)
- magnetic resonance (3)
- myocardial perfusion (3)
- myocardium (3)
- quantification (3)
- radiography (3)
- radiology (3)
- radiomics (3)
- spectroscopy (3)
- stroke (3)
- 18F-FDG PET/CT (2)
- 31P-MRS (2)
- AMADEUS (2)
- ATP (2)
- Absolutquantifizierung (2)
- Aortenklappenersatz (2)
- Aortenstenose (2)
- Appendizitis (2)
- Bildqualität (2)
- CT (2)
- Computed tomography (2)
- Cystic fibrosis (2)
- DW-MRI (2)
- DWI (2)
- Diffusions-MRT (2)
- Diffusionsgewichtete Magnetresonanztomographie (2)
- Dosisreduktion (2)
- Dual-Source-Computertomographie (2)
- Echtzeit (2)
- Fabry disease (2)
- Hand (2)
- Heart (2)
- Interventionelle Radiologie (2)
- Late Enhancement (2)
- Leber (2)
- Leberzirrhose (2)
- Lungenembolie (2)
- MUS (2)
- Medulloblastom (2)
- Myocardial infarction (2)
- Myokardinfarkt (2)
- NMR-Mammographie (2)
- NMR-Spektroskopie (2)
- PET/CT (2)
- Periphere arterielle Verschlusskrankheit (2)
- Punktion (2)
- Rotatorenmanschette (2)
- Sauerstoff (2)
- Schockraumalgorithmus (2)
- Schulter (2)
- SonoVue (2)
- Stent (2)
- TFCC (2)
- VUR (2)
- Wertigkeit (2)
- X-ray computed (2)
- acute myocardial infarction (2)
- aneurysms (2)
- angiography (2)
- aorta (2)
- aortic stenosis (2)
- blood flow (2)
- bone (2)
- cardiac (2)
- cardiac spectroscopy (2)
- cartilage (2)
- case report (2)
- central nervous system (2)
- contrast media (2)
- cystic fibrosis (2)
- data acquisition (2)
- dose reduction (2)
- echocardiography (2)
- elbow joint (2)
- endovascular therapy (2)
- first pass (2)
- follow-up (2)
- harmonic imaging (2)
- imaging (2)
- interventional radiology (2)
- joint instability (2)
- knee (2)
- lesions (2)
- mammography (2)
- microvascular obstruction (2)
- mikrovaskuläre Obstruktion (2)
- mouse (2)
- muscle degeneration (2)
- no reflow (2)
- outcome (2)
- oxygen-enhanced (2)
- pattern (2)
- perfusion (2)
- preclinical research (2)
- prostate cancer (2)
- pulmonary embolism (2)
- recurrence (2)
- relapse (2)
- renal artery (2)
- rotator cuff tear (2)
- shoulder (2)
- shoulder surgery (2)
- skull (2)
- therapy (2)
- tomography (2)
- translational research (2)
- tumor (2)
- wrist (2)
- 0 (1)
- 0.2 Tesla (1)
- 11C-Methionine PET/CT (1)
- 13C-Methacetin-Atemtest (1)
- 1H-Magnetic resonance spectroscopy (1H-MRS) (1)
- 2 Tesla (1)
- 2-dimensional speckle tracking (1)
- 2D-SPLASH (1)
- 2D-perfusion angiography (1)
- 3 Tesla (1)
- 3,0 Tesla (1)
- 3.0 Tesla (1)
- 31-P-MR-Spectroskopie (1)
- 31-P-Magnetresonanztomographie (1)
- 31P (1)
- 31P-MR-Spectroscopy (1)
- 31P-MR-Spektroskopie (1)
- 31P-MR-spectroscopy (1)
- 3D printing (1)
- 3D-CSI (1)
- 3 T (1)
- 4D flow cardiovascular magnetic resonance (1)
- 4D-MRI (1)
- 68Ga-Pentixafor PET/CT (1)
- 7 T (1)
- 7T (1)
- ADC (1)
- AMARES (1)
- ASE formula (1)
- ATRT (1)
- AW-CSI (1)
- Abdomen (1)
- Absolutkonzentrationen (1)
- Abszess (1)
- Acoustic radiation force imaging (ARFI) (1)
- Adaptive cell transfer (1)
- Adenosin (1)
- Akromioklavikulargelenk (1)
- Akute Extremitätenischämie (1)
- Alter (1)
- Amputation (1)
- Anderson-Fabry Disease (1)
- Aneurysma (1)
- Aneurysmen (1)
- Angiographie (1)
- Angioplastie (1)
- Anisotrope Diffusion (1)
- Aortic Valve Replacement (1)
- Applied physics (1)
- Arterial Diameters (1)
- Arterien (1)
- Arthrography (1)
- Arthroskopie (1)
- Atherosklerose (1)
- Atmung (1)
- Atrophie (1)
- Auswertung (1)
- B (1)
- B0 correction (1)
- B0-Korrektur (1)
- BM (1)
- BMI (1)
- BOLD (1)
- BPD (1)
- Bauchspeicheldrüsentumor (1)
- Beckengefäße (1)
- Beingefäße (1)
- Bestimmung des Relaxations-Parameters in der Magnetresonanztomografie (1)
- Bewegungsfixateur (1)
- Bilderzeugung (1)
- Biliary (1)
- Biomedical engineering (1)
- Biopsie (1)
- Bizepssehnenpathologie (1)
- Blutflussgeschwindigkeit (1)
- Bluthochdruck (1)
- Bolustriggerung (1)
- Breiter Rückenmuskel (1)
- Brustkompression (1)
- Bänder (1)
- CCS (1)
- CD38 (1)
- CINE (1)
- CMR (1)
- CMV (1)
- CRC (1)
- CT perfusion (1)
- CT-angiography (1)
- CT-gesteuerte Punktion (1)
- CTNNB1 (1)
- Cancellous bone (1)
- Carcinomatosis (1)
- Cardiac magnetic resonance imaging (1)
- Cardiac ventricles (1)
- Cardiomyopathy (1)
- Cardioperfusion (1)
- Children (1)
- Cisplatin (1)
- Clinical Genetics (1)
- Cold pressure test (1)
- Computed axial tomography (1)
- Computer-aided diagnosis (1)
- Computertomografie (1)
- Computertomograph (1)
- Computertomographie Angiographie (1)
- Computertomography Angiography (1)
- Cone-beam computed tomography (1)
- Convolutional Neural Network (1)
- Crohn’s disease (1)
- Cushing’s disease (1)
- Cushing’s syndrome (1)
- Cystic fibrosis liver disease (CFLD) (1)
- Cystische Fibrose (1)
- D313Y genotype (1)
- DCIS (1)
- DCM (1)
- DIPG (1)
- DM (1)
- DSA (1)
- DTI (1)
- Darmsonographie (1)
- Data acquisition (1)
- Datenbank (1)
- Deep learning (1)
- Definition (1)
- Delayed Enhancement (1)
- Density Weighting (1)
- Desmoplakin (1)
- Diagnose (1)
- Diagnostic medicine (1)
- Diagnostik (1)
- Dichtegewichtete Bildgebung (1)
- Dichtegewichtung (1)
- Differentialdiagnose (1)
- Diffusion (1)
- Diffusion Tensor Imaging (1)
- Diffusion tensor imaging (1)
- Diffusionsgewichtete Bildgebung (1)
- Digitale Subtraktionsangiographie (1)
- Digitalisierung (1)
- Divertikulitis (1)
- Donor lymphocytes (1)
- Doppelkontrastpharyngographie (1)
- Dopplersonographie (1)
- Drainage (1)
- Dual-Source Computertomography (1)
- Duplexsonographie (1)
- EULAR guidelines (1)
- EVT (1)
- Echo Planar Imaging (1)
- Echo planar imaging (1)
- Echogenität (1)
- Echoplanar-Bildgebung (1)
- Echoplanare Bildgebung (1)
- Echosignalverstärker (1)
- Eigenvectors (1)
- Elastographie (1)
- Elbow (1)
- Elbow joint (1)
- Ellenbogengelenk (1)
- Embolisation (1)
- Entwicklung (1)
- Exercise capacity (1)
- Experimentelle Bildgebung (1)
- Experimentelle allergische Neuritis (1)
- Extracellular volume (1)
- Extracorporeal membrane oxygenation (1)
- Fabry cardiomyopathy (1)
- Fabry nephropathy (1)
- Fabry-associated pain (1)
- Farbduplexgeräte (1)
- Fats (1)
- Feldstärke (1)
- Fett (1)
- Fibrose (1)
- First pass (1)
- Flow (1)
- Fluss (1)
- Flußgeschwindigkeit (1)
- Friedreich's Ataxia (1)
- Friedreich-Ataxie (1)
- Frühgeborenes (1)
- Frühphase (1)
- Funktionelle Kernspintomografie (1)
- Funktionsanalyse <Medizin> (1)
- GCA (1)
- GFAP (1)
- Galaktographie (1)
- Galle (1)
- Gallengangsstenose (1)
- Ganzkörpercomputertomographie bei Kindern (1)
- Gefäßverschluss (1)
- Gehirn (1)
- Gelatineschwamm (1)
- Gelenkinstabilität (1)
- Geschlecht (1)
- Gesicht (1)
- Gesundheits-App (1)
- Giant cell arteritis (GCA (1)
- Glukokortikoide (1)
- Glukokortikoideinsparende Therapie (1)
- HMDP hydroxymethylene diphosphonate (1)
- Heartdisease (1)
- Hepatozelluläres Karzinom (1)
- Herzerkrankung (1)
- Herzfunktion (1)
- Herzmetabolismus (1)
- Herzmuskelkrankheit (1)
- Herzwandbewegung (1)
- Hochfeld (1)
- Hypertrophische Herzmuskelkrankheit (1)
- Hyperämie (1)
- Hypophyse (1)
- Hypophysenhormon (1)
- ICRS (1)
- ISS (1)
- Image Quality (1)
- Imaging (1)
- Imaging techniques (1)
- Immunotherapy (1)
- Inflammatory diseases (1)
- Informationsverarbeitung (1)
- Interventional radiology (1)
- Interventionen (1)
- Intrakranielles Aneurysma (1)
- Intravenöse Applikation (1)
- JCV (1)
- Juvenile biventricular cardiomyopathy (1)
- KOOS (1)
- Karpus (1)
- Kinderheilkunde (1)
- Kinderradiologie (1)
- Kindesalter (1)
- Kleinhirntumor (1)
- Kohlenstoff-13-Exhalationstest (1)
- Komplikation (1)
- Konservative Therapie (1)
- Korrelation (1)
- Kraniopharyngeom (1)
- Kraniostenose (1)
- Krebsvorsorge (1)
- Kritische Extremitätenischämie (1)
- Künstliche Intelligenz (1)
- L-arginine (1)
- Langzeitergebnisse (1)
- Large vessel vasculitides (LVV) (1)
- Late Gadolinium Enhancement (1)
- Lebensqualität (1)
- Leberfibrose (1)
- Leberfunktion (1)
- Lebertumor (1)
- Lebertumore (1)
- Lebertumoren (1)
- Leberversagen (1)
- Leberzellkrebs (1)
- Levovist (1)
- Literatur (1)
- Liver CT (1)
- Lung (1)
- Lung disease, (1)
- Lungenfunktionsdiagnostik (1)
- Lymphogranulomatose (1)
- M2 (1)
- MCU (1)
- MDCT (1)
- MOLLI (1)
- MOR202 (1)
- MPI (1)
- MPI <Bildgebendes Verfahren> (1)
- MR (1)
- MR angiography (1)
- MR arthrography (1)
- MR guided biopsy (1)
- MR-Arthrographie (1)
- MR-Spectroscopie (1)
- MR-Tomographie (1)
- MR-Urography Pediatric (1)
- MR-spectroscopy (1)
- MRI spectroscopy (1)
- MRT-Tomographie (1)
- MS (1)
- Magnetic Particle Imaging (1)
- Magnetic Resonance Relaxometry (1)
- Magnetic Resonance Spectroscopy Imaging (1)
- Magnetic resonance (three dimensional) (1)
- Magnetic resonance imaging (1)
- Magnetic resonance imaging(MRI) (1)
- Magnetpartikelbildgebung (1)
- Magnetresonanz (1)
- Magnetresonanz-Enterographie (1)
- Magnetresonanz-Relaxometrie (1)
- Magnetresonanzangiographie (1)
- Makrophage (1)
- Maligne Tumoren (1)
- Mamillensekretion (1)
- Mamma (1)
- Marfan syndrome (1)
- Maschinelles Lernen (1)
- Mastoid process (1)
- Medizinische Radiologie (1)
- Medulloblastoma (1)
- Meningeose (1)
- Meningeosis (1)
- Merkel cell carcinoma (1)
- Messprozess (1)
- Metabolomic Imaging (1)
- Metabolomics (1)
- Metastase (1)
- Methotrexat (1)
- Methotrexate (1)
- Mikrosomale Leberfunktion (1)
- Mikrovaskuläre Obstruktion (1)
- Miktionsurosonographie (1)
- Miktionszystourethrographie (1)
- Mitoxantron (1)
- Mitoxantrone (1)
- Model Based Reconstruction Algorithms in Magnetic Resonance Imaging (1)
- Modellbasierte-Rekonstruktionsalgorithmen in der Magnetresonanztomografie (1)
- Molecular imaging (1)
- Morbus Crohn (1)
- Morphing (1)
- Morphologie (1)
- Mukoviszidose (1)
- Multidetector computed tomography (1)
- Multiples Myelom (1)
- Multivoxel (1)
- Muscle function (1)
- Muscle power (1)
- Muskelatrophie (1)
- Muskelverfettung (1)
- Myeloma (1)
- Myokardfibrose (1)
- Myokardiale Perfusion (1)
- Myokardperfusion (1)
- NIHSS (1)
- NMR relaxation (1)
- NR3C1 (1)
- Natrium (1)
- Navigator (1)
- Nephrokalzinose (1)
- Nervenfaser (1)
- Neugeborenes (1)
- Neuroblastom (1)
- Neurochirurgie (1)
- NfL (1)
- Nichtionisches Kontrastmittel (1)
- Nierenarterie (1)
- Nierenarterien (1)
- Non-rigid image registration (1)
- Notfallmedizin (1)
- Off.Resonanzen (1)
- Onkologie (1)
- Optimierung (1)
- Organfilter (1)
- Orthopädische Chirurgie (1)
- PCI (1)
- PCr (1)
- PEFB (1)
- PET (1)
- PLAG1 rearrangement (1)
- PML (1)
- PMR (1)
- PNET (1)
- PROM (1)
- PROMM (1)
- PSMA (1)
- PSMA-RADS (1)
- PTA (1)
- Palmoplantar keratoderma (1)
- Pancreas CT (1)
- Pankreaskarzinom (1)
- Pankreaskarzinom präoperativ (1)
- Parallele Bildgebung (1)
- Paralleler Prozess (1)
- Perfusions-CT (1)
- Perfusionscomputertomographie (1)
- Peripheral Artery Disease (1)
- Peripheres Nervensystem (1)
- Perkutane transhepatische Cholangiodrainage (1)
- Perkutane transluminale Angioplastie (1)
- Pharynx (1)
- Phasecontrast Imaging (1)
- Phasenkontrast (1)
- Phasenkorrektur (1)
- Phosphor (1)
- Phosphor-31-NMR-Spektroskopie (1)
- Phosphormetaboliten (1)
- Phosphorylation (1)
- Planimetrie (1)
- Plasmozytom (1)
- Plattform (1)
- Pneumothorax (1)
- Point Spread Function (1)
- Positron emission tomography (1)
- Primary hyperparathyroidism (pHPT) (1)
- Prodigy (1)
- Prostatakrebs (1)
- Prostate cancer diagnostics (1)
- Protonen-MR-Spektroskopie (1)
- Protonen-NMR-Spektroskopie (1)
- Prä-Bolus Untersuchung (1)
- Präbolus (1)
- Präbolus Technik (1)
- Pyramidenbahn (1)
- Quantitativ (1)
- Quantitative 31P-MR- Spektroskopie (1)
- Quantitative Sonoelastographie (1)
- ROC-Kurve (1)
- Radiation exposure (1)
- Radiologische Diagnostik (1)
- Radiotherapy treatment planning (1)
- Raumforderung (1)
- Read-out (1)
- Relaxation Parameter Mapping in Magnetic Resonance Imaging (1)
- Respiratory induced tumor motion (1)
- Rezidiv (1)
- Rezidivmuster (1)
- Riesenzellarteriitis (1)
- Rotatorenmanschettenläsion (1)
- Rotatorenmanschettenruptur (1)
- Röhrenstromanpassung (1)
- SASHA (1)
- SL-Band (1)
- SLAP-Läsion (1)
- SLAP-lesion (1)
- SP-fixation (1)
- SPECT (1)
- SPIO-Partikel (1)
- ST-elevation myocardial infarction (1)
- STEMI (1)
- Scar (1)
- Schmerz (1)
- Schneideballon (1)
- Schockraumbehandlung (1)
- Segmentation (1)
- Sensitivität (1)
- Sequenzvergleich (1)
- Severely injuried child (1)
- ShMOLLI (1)
- Shuntstenose (1)
- Sigmadivertikulitis (1)
- Single-Source-Dual-Energy-CT (1)
- Singlevoxel (1)
- Soft tissues (1)
- Somatostatin receptor expression (1)
- Sonographie (1)
- Spezifität (1)
- Spiral-CT (1)
- Spiral-Computertomographie (1)
- Split-Filter-Dual-Energy-CT (1)
- Staging (1)
- Stanzbiopsie (1)
- Stentfracture (1)
- Stentfraktur (1)
- Stichkanalembolisation (1)
- Strahlendosis (1)
- Strahlenexposition (1)
- Strahlenschutz (1)
- Stress (1)
- Strukturwandel (1)
- Störabstand (1)
- Subarachnoidalblutung (1)
- Swine (1)
- T1 mapping (1)
- T1-Mapping (1)
- TPM (1)
- Tagging (1)
- Teichholz formula (1)
- Tesla (1)
- Therapie (1)
- Tissue Phase Mapping (1)
- Tocilizumab (1)
- Tomography (1)
- Tractography (1)
- Transarterielle Chemoembolisation (1)
- Transluminale Angioplastie (1)
- Trauma (1)
- Traveling Wave Magnetic Particle Imaging (1)
- Triangular fibrocartilage (1)
- Triangulärer fibrokartilaginärer Komplex (1)
- Tumor (1)
- Tumorentdeckungsrate (1)
- Turbo Spin Echo (1)
- US (1)
- USP28 (1)
- USP8 (1)
- Ultraschall-Elastographie (1)
- Ultraschallkontrastmittel (1)
- Ultrasound (1)
- VCUG (1)
- VIDE (1)
- VIDED (1)
- VUS (1)
- Vakuumstanzbiopsie (1)
- Vascular closure devices (1)
- Vasculitis (1)
- Vaskuläre Rekonstruktion (1)
- Vasospasm (1)
- Vasospasmen (1)
- Vena cava inferior (1)
- Ventilation (1)
- Ventricular septal rupture (1)
- Vergleich konservative digitale Röntgentechnik (1)
- Verlgeich (1)
- Vitalitätsdiagnostik (1)
- Wernicke's perpendicular fasciculus (1)
- Wernickes Assoziationsbündel (1)
- Whole-body-computertomography (1)
- Wrist (1)
- X-ray radiography (1)
- Zangenbiopsie (1)
- Zentralnervensystem (1)
- [18F]FDG PET/CT (1)
- [18F]FDG-PET-CT (1)
- \(^{18}\)F-PSMA-1007 (1)
- abdominal lymph node metastases (1)
- abdominale Bildgebung (1)
- abscess (1)
- absolute metabolite concentrations (1)
- ac-joint (1)
- access site complications (1)
- acute lower-extremity ischemia (1)
- adjunctive endovascular procedures (1)
- adolescents (1)
- adrenocortical (1)
- age dependency (1)
- akuter Myokardinfarkt (1)
- algorithms (1)
- alkaline phosphatase (1)
- amyloidosis (1)
- aneurysmal subarachnoid hemorrhage (1)
- angioplasty (1)
- animal model (1)
- ankle (1)
- anorectal angl (1)
- antegrade puncture (1)
- aortal valve stenosis (1)
- aortic dissection (1)
- apolipoprotein-E (1)
- appendicitis (1)
- arteria femoralis superficialis (1)
- arteria poplitea (1)
- arteriitis temporal arteriitis (1)
- arthroscopy (1)
- artificial intelligence (1)
- asfotase alfa (1)
- aspiration (1)
- association (1)
- atheriosclerosis (1)
- atherosclerosis (1)
- atrophy of muscles (1)
- atypical (1)
- atypical teratoid/rhabdoid tumor (1)
- atypischer teratoid/rhabdoider Tumor (1)
- auditiver Kortex (1)
- auditory cortex (1)
- biliäre Stenose (1)
- biliäre Striktur (1)
- biomedical engineering (1)
- bisphosphonates (1)
- bladder cancer (1)
- blade angioplastie (1)
- blood coagulation factor XIII (1)
- bolus tracking (1)
- bone biology (1)
- bone bruise (1)
- bone fractures (1)
- bone marrow edema (1)
- bone marrow lesion/edema (1)
- bone remineralization (1)
- bone-marrow (1)
- bowel sonography (1)
- brain metastases (1)
- brainstem glioma (1)
- breast (1)
- breast cancer (1)
- breast cancer imaging (1)
- c-reactive protein (1)
- cable-clamp implants (1)
- cancellous bone (1)
- cancer (1)
- cancer detection rate (1)
- cancer imaging (1)
- cancer screening (1)
- carcinoma (1)
- carcinoma metastases to pancreas (1)
- cardiac MRI (1)
- cardiac breathing (1)
- cardiac function (1)
- cardiac imaging (1)
- cardiac infarction (1)
- cardiac magnetic resonance (1)
- cardiac metabolism (1)
- cardiac transplantation (1)
- cardiomyopathy (1)
- cardiovascular MRI (1)
- cardiovascular magnetic resonance (1)
- cardiovascular magnetic resonance (CMR) (1)
- cartilage defect (1)
- central venous catheter (1)
- cerebral arteries (1)
- cerebral metastases (1)
- cerebrospinal fluid (1)
- cervical vertebrae pneumatization (1)
- chemotherapy (1)
- chiasma antebrachii (1)
- chondral defect (1)
- chronic mesenteric ischemia (1)
- chronisch-entzündliche Darmerkrankung (1)
- cine loop (1)
- cirrhosis (1)
- classification (1)
- clinical manifestations (1)
- cold pressor test (1)
- color-coded (1)
- color-coding (1)
- colorectal cancer (1)
- complication aortic-aneurysm (1)
- computational neural networks (1)
- computed tomography angiography (CTA) (1)
- concomitant radiotherapy (1)
- cone-beamcomputed tomography (1)
- constrastagent (1)
- continuous extracorporeal femoral perfusion model (1)
- contrast agent (1)
- contrast agents (1)
- contrast medium (1)
- contrast-enhanced (1)
- contrast-enhanced ultrasound (1)
- conventional imaging (1)
- convolution kernel (1)
- convolutional neural network (1)
- convolutional neural networks (1)
- coracohumeral distance (1)
- coracohumeral impingement (1)
- coronary arteries (1)
- corpus cavernosum (1)
- correlation (1)
- corticosteroid treatment (1)
- cranial (1)
- craniopharyngioma (1)
- cross-sectional imaging (1)
- ct-scan (1)
- cutting balloon (1)
- daratumumab (1)
- data base (1)
- database (1)
- deformation (1)
- delayed enhancement (1)
- density (1)
- density weighted imaging (1)
- density weighting (1)
- deterministic (1)
- diagnostics (1)
- diffus intrinsisches Ponsgliom (1)
- diffusion tractography (1)
- diffusion weighted mri (1)
- diffusion-weighted MRI (1)
- digital subtraction angiography (1)
- digital subtraction angiography (DSA) (1)
- digital transformation (1)
- disease (1)
- distal occlusion (1)
- dorsal instrumentation (1)
- double-blind (1)
- double-contrast pharyngography (1)
- drainage-treatment (1)
- drug-eluting beads (1)
- dual-energy (1)
- dual-energy CT (1)
- dual-energy computed tomography (1)
- dual-room trauma suite (1)
- dual-room whole-body CT (1)
- dual-source CT (1)
- duktal (1)
- dynamic (1)
- dynamisch (1)
- echo planar imaging (1)
- echogenicity (1)
- ejection fraction (1)
- electrical and electronic engineering (1)
- embolism/thrombosis (1)
- encephalitis (1)
- endothelium (1)
- endovascular repair (1)
- endovascular treatment (1)
- endovaskulär (1)
- endovaskuläre Therapie (1)
- enhancement (1)
- epicondyles (1)
- erythrocyte sedimentation-rate (1)
- evaluation (1)
- experimental imaging (1)
- experimental models of disease (1)
- exposure of radiation (1)
- extramedullary hematopoiesis (1)
- extremities (1)
- extremity trauma (1)
- fMRT (1)
- fabry's disease (1)
- face morphing (1)
- facial age (1)
- facial gender (1)
- farbkodierte DSA (1)
- fatty degeneration (1)
- fatty infiltration (1)
- femoral access (1)
- femoral arteries (1)
- fenestration (1)
- fibre tracking (1)
- fibroblast activation protein (1)
- fibrosis (1)
- flexor digitorum superficialis (1)
- flexor tendon (1)
- flow patterns (1)
- fluoroscopy (1)
- forearm (1)
- fracture (1)
- fracture-associated vascular damage (1)
- fractures, bone (1)
- fragility fracture (1)
- free respiration (1)
- free‐breathing (1)
- freie Atmung (1)
- functional MRI (1)
- functional analysis (1)
- functional imaging (1)
- functional magnetic resonance imaging (1)
- g-factor (1)
- gadoliniumhaltiges Kontrastmittel (1)
- galaoctography (1)
- gefitinib (1)
- gelatin sponge (1)
- gender (1)
- general anaesthesia (1)
- glial damage (1)
- glial fibrillary acidic protein (1)
- glucocorticoid excess (1)
- glucocorticoid-sparing agents (1)
- glucocorticoids (1)
- goutallier (1)
- gradient impulse response function (1)
- gradient system respose (1)
- gradient system trasfer function (1)
- grading system of chondral defects (1)
- harmonische Bildgebung (1)
- head and neck (1)
- head and neck cancer (1)
- healing and remodelling processes (1)
- heart metabolism (1)
- hemodialysis (1)
- hemodynamics (1)
- hepatocellular carcinoma (1)
- hepatocellular carcinoma (HCC) (1)
- hepatozelluläres Karzinom (HCC) (1)
- high blood pressure (1)
- high risk (1)
- high tibial osteotomy (1)
- high-energy-phosphate metabolism (1)
- hinged external fixator (1)
- hodgkin's lymphoma (1)
- hypercortisolism (1)
- hypertrophic cardiomyopathy (1)
- hypophosphatasia (1)
- identification (1)
- idiopathic fecal incontinence (1)
- image analysis (1)
- image processing (1)
- image quality (1)
- image segmentation (1)
- imaging techniques (1)
- immune check inhibitor (1)
- impact (1)
- in vivo imaging (1)
- infarction size (1)
- inferior vena cava (1)
- infiltrate (1)
- inflammation (1)
- inherited metabolic disorders (1)
- interventional procedures (1)
- interventional therapy (1)
- interventionelle Radiologie (1)
- interventionelle Therapie (1)
- intracranial (1)
- intracranial lesions (1)
- intracranial tumors (1)
- intrakraniell (1)
- intrakranielle Läsionien (1)
- intrakranielle Tumoren (1)
- intramyokardiale Einblutung (1)
- intravascular ultrasound (IVUS) (1)
- intravenös (1)
- ionizing radiation (1)
- ischemic stroke (1)
- juvenile idiopathic arthritis (1)
- ketogenic diet (1)
- ketone bodies (1)
- kranial (1)
- large animal models (1)
- large vessel occlusion (1)
- large-vessel vasculitis (1)
- late gadolinium-enhancement (1)
- late thrombectomy (1)
- left lateral wall (1)
- left ventricular hypertrophy (1)
- left ventricular mass index (1)
- level of evidence: IV (1)
- ligaments (1)
- lipoblastoma (1)
- literature (1)
- livertumour (1)
- local point-spread function (1)
- long-term results (1)
- lower extremity (1)
- lymphatic metastasis (1)
- magnetic particle imaging (1)
- magnetic resonance (vascular studies) (1)
- magnetic resonance imaging MRI (1)
- maligne untere Einflussstauung (1)
- mammographic compression (1)
- matched filters (1)
- mechanical thrombectomy (1)
- medical research (1)
- medulloblastoma (1)
- mesenteric stenting (1)
- meta-analysis (1)
- metabolic profile (1)
- metabolism (1)
- mice (1)
- mikrochirurgische Resektion (1)
- minimal invasive surgery (1)
- minimalinvasiv (1)
- molecular diagnostics (1)
- molecular imaging (1)
- motor cortex (1)
- movable sliding gantry (1)
- mr spectroscopy (1)
- mrs (1)
- multiparametric CT (1)
- multiples myeloma (1)
- multivoxel (1)
- musculoskeletal system (1)
- muskuloskelettalen Bildgebung (1)
- myocardial blood flow (1)
- myokardiale Perfusion (1)
- neoadjuvant therapies (1)
- neonatal (1)
- nephrocalcinosis (1)
- neural networks (1)
- neurofilament light chain (1)
- neurology (1)
- neuronavigation (1)
- neuroradiology (1)
- neurosurgery (1)
- nipple discharge (1)
- nnU-net (1)
- non-small-cell lung (1)
- novel human cadaveric perfusion model (1)
- obesity (1)
- ocular manifestations (1)
- oedema (1)
- ollimator (1)
- oncology (1)
- ophthalmic artery (1)
- optic nerve (1)
- orbit (1)
- organ filters (1)
- organoid (1)
- orthopedic surgery (1)
- osteoarthritis (1)
- osteomalacia (1)
- osteoporosis (1)
- outcome prediction (1)
- paediatrics (1)
- pain (1)
- palliative care (1)
- parallel imaging (1)
- parathyroid carcinoma (1)
- patency rate (1)
- pathology (1)
- pediatric (1)
- pediatrics (1)
- pedicle screws (1)
- pelvic trauma (1)
- pembrolizumab (1)
- penile thrombosis (1)
- percutaneous biliary drainage (1)
- perfusion imaging (1)
- perfusion map (1)
- peripheral nervous system (1)
- peripheral vascular tree (1)
- perkutan (1)
- perkutane Rotationsthrombektomie (1)
- pharynx (1)
- phase-contrast MRI (1)
- phosphor (1)
- photo app (1)
- photon-counting (1)
- photon-counting CT (1)
- photon-counting computed tomography (CT) (1)
- photon-counting-detector CT (1)
- pig (1)
- plasmocytoma (1)
- polymyalgia rheumatica (1)
- polymyalgia-rheomatica (1)
- positive nodal status (1)
- post-neoadjuvant therapies (1)
- post-reconstruction filtering (1)
- pre-bolus technique (1)
- prebolus (1)
- prebolus technique (1)
- preoperative localization (1)
- prestyloid recess (1)
- preterm infants (1)
- priapism (1)
- primitive neuroectodermal tumor (1)
- primitiver neuroektodermaler Tumor (1)
- probabilistic (1)
- prognosis (1)
- prognostic marker on MRI (1)
- prognostische Marker (1)
- progression (1)
- proton-MR-spectroscopy (1)
- pränatal (1)
- pterionaler Zugang (1)
- pubic symphysis (1)
- pulmonary arteries (1)
- pädiatrischen Tumoren (1)
- pädiatrisches Polytrauma (1)
- quality (1)
- quality of life (1)
- radial (1)
- radiation dosage (1)
- radiation dose (1)
- radiation dose reduction (1)
- radiation myelitis (1)
- radiation protection (1)
- radical cystectomy (1)
- radiogenomics (1)
- radiologische Diagnostik im Schockraum (1)
- rare bone disease (1)
- read-outs (1)
- real-time (1)
- real-time imaging (1)
- refractory (1)
- regression analysis (1)
- relaxation (physics) (1)
- relaxation time (1)
- renal arteries (1)
- renal system (1)
- repeat surgery (1)
- repeated surgery (1)
- reproducibility (1)
- reproducibility of results (1)
- research infrastructure (1)
- resolution (1)
- resuscitation time (1)
- retroperitoneal tumor (1)
- rickets (1)
- rotational percutaneous mechanical thrombectomy (1)
- rotator cuff lesion (1)
- sacral nerve stimulation (1)
- sacral neuromodulation (1)
- salvage radiotherapy (1)
- sauropod dinosaurs (1)
- scanner (1)
- scannernoise (1)
- seahorse (1)
- segmentation (1)
- self‐gated (1)
- semantic segmentation (1)
- sensitivity (1)
- sequence imaging protocol (1)
- shimming (1)
- signal filtering (1)
- signal to noise ratio (1)
- singlevoxel (1)
- skeletal (1)
- small animal SPECT (1)
- small bowel MRI (1)
- small pixel effect (1)
- small-animal imaging (1)
- small-cell lung (1)
- smoking (1)
- smoldering myeloma (1)
- sodium (1)
- specifity (1)
- spectral CT (1)
- spectral imaging (1)
- spectroscopic sequences (1)
- spin labeling (1)
- spinal (1)
- spine (1)
- spine trauma (1)
- spiral trajectory (1)
- spleen (1)
- squamous tumors (1)
- staging (1)
- standardized reporting system (1)
- statistical data (1)
- stem cell transplantation (1)
- stenosis (1)
- stent (1)
- stent retriever (1)
- stents (1)
- stress (1)
- subarachnoid hemorrhage (1)
- subscapularis tear (1)
- superparamagnetic iron oxide particles (1)
- supraspinatus (1)
- supratentorial (1)
- supratentoriell (1)
- surgery (1)
- surgical repair (1)
- surgical trauma room (1)
- surgical treatment (1)
- sympathetic stimulation (CPT) (1)
- synovitis (1)
- systematic review (1)
- systemic vasculitides (1)
- tagging (1)
- temperature dependency (1)
- tetraparesis (1)
- thermal variation (1)
- thorax (1)
- three-dimensional imaging (1)
- totally implantable venous access port (1)
- tract embolization (1)
- transarterial chemoembolization (1)
- transarterial chemoembolization (TACE) (1)
- transarterielle Chemomebolisation (TACE) (1)
- transcranial dopplersonography (1)
- transfer learning (1)
- trauma centre (1)
- trauma management (1)
- traumatisch (1)
- traveling wave magnetic particle imaging (1)
- triangular fibrocartilage (1)
- triangular fibrocartilage complex (1)
- triglycerides (1)
- tube current modulation (1)
- tumor burden (1)
- ultrahigh field (1)
- ultrahigh resolution (1)
- ultrahigh-field (1)
- ultrahigh-field MRI (1)
- undersampling (1)
- vacuum-assisted biopsy (1)
- variational network (1)
- vascular (1)
- vascular access (1)
- vascular reconstruction (1)
- vasculature (1)
- vasculitis (1)
- vertebral pedicles (1)
- vertebral pneumaticity (1)
- virtual non-contrast (1)
- virtual noncalcium imaging (1)
- vitality of heart muscle (1)
- voiding cystourethrography (1)
- voiding urosonography (1)
- volume determination (1)
- wall shear stress (1)
- wave‐CAIPI (1)
- whole-body MRI (1)
- whole-body imaging (1)
- workflow (1)
- x-ray computed (1)
- zoledronic acid (1)
- Ödem (1)
- β-Hydroxybutyrate (1)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (240) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
Background
Merkel cell carcinoma (MCC) is a rare cutaneous neoplasm with increasing incidence, aggressive behavior and poor prognosis. Somatostatin receptors (SSTR) are expressed in MCC and represent a potential target for both imaging and treatment.
Methods
To non-invasively assess SSTR expression in MCC using PET and the radiotracers [68Ga]DOTA-D-Phe1-Tyr3-octreotide (DOTATOC) or -octreotate (DOTATATE) as surrogate for tumor burden. In 24 patients with histologically proven MCC SSTR-PET was performed and compared to results of computed tomography (CT).
Results
SSTR-PET detected primary and metastatic MCC lesions. On a patient-based analysis, sensitivity of SSTR-PET was 73% for nodal metastases, 100% for bone, and 67% for soft-tissue metastases, respectively. Notably, brain metastases were initially detected by SSTR-PET in 2 patients, whereas liver and lung metastases were diagnosed exclusively by CT. SSTR-PET showed concordance to CT results in 20 out of 24 patients. Four patients (17%) were up-staged due to SSTR-PET and patient management was changed in 3 patients (13%).
Conclusion
SSTR-PET showed high sensitivity for imaging bone, soft tissue and brain metastases, and particularly in combination with CT had a significant impact on clinical stage and patient management.
This study aimed to explore the correlation between imaging patterns and clinical features in patients with smoldering multiple myeloma (SMM) who simultaneously underwent 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT). We retrieved and analyzed clinical characteristics and PET imaging data of 10 patients with SMM. We found a significant correlation between bone marrow (BM) plasma cell (PC) infiltration and mean standardized uptake values (SUV\(_{mean}\)) of lumbar vertebrae L2-L4 on 11C-Methionine PET/CT scans (r = 0.676, p = 0.031) and 68Ga-Pentixafor PET/CT scans (r = 0.839, p = 0.002). However, there was no significant correlation between BM involvement and SUV\(_{mean}\) of lumbar vertebrae L2-L4 on 18F-FDG PET/CT scans (r = 0.558, p = 0.093). Similarly, mean target-to-background ratios (TBR\(_{mean}\)) of lumbar vertebrae L2-L4 also correlated with bone marrow plasma cell (BMPC) infiltration in 11C-Methionine PET/CT (r = 0.789, p = 0.007) and 68Ga-Pentixafor PET/CT (r = 0.724, p = 0.018) PET/CT. In contrast, we did not observe a significant correlation between BMPC infiltration rate and TBR\(_{mean}\) in 18F-FDG PET/CT (r = 0.355, p = 0.313). Additionally, on 11C-Methionine PET/CT scans, we found a significant correlation between BMPC infiltration and TBR\(_{max}\) of lumbar vertebrae L2-L4 (r = 0.642, p = 0.045). In conclusion, 11C-Methionine and 68Ga-Pentixafor PET/CT demonstrate higher sensitivity than 18F-FDG PET/CT in detecting BM involvement in SMM.
Background
Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI.
Methods
49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated.
Results
Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PD\(_{outflow}\)/PD\(_{inflow}\) increased by 65% (p < 0.001) and AUC\(_{outflow}\)/AUC\(_{inflow}\) increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05).
Conclusions
Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.
Da die häufigste Ursache der pathologischen Mamillensekretion ein benigner Prozess ist, sollte die Diagnostik mittels nicht invasiver Verfahren im Vordergrund stehen. Dabei stellt die Kernspintomographie eine wichtige Modalität dar, vor allem wenn die Mammographie und die Mammasonographie keine Befunde zeigen. In dieser Studie wurden Patientinnen mit pathologischer Mamillensekretion mittels MR-Mammographie bei 3,0 Tesla und anschließend mittels Galaktographie untersucht.
Von Juli 2009 bis Juni 2012 wurden 50 Patientinnen in die Studie eingeschlossen, die eine pathologische Mamillensekretion zeigten und einer MR-Mammographie bei 3,0 Tesla zustimmten. Bei allen Studienteilnehmerinnen waren sowohl die Mammographie als auch die Mammasonographie negativ oder zeigten einen unklaren Befund. Weitere Einschlusskriterien waren im Normbereich liegende Nieren- und Prolaktinwerte.
Sechs Patientinnen zeigten einen beidseitigen Ausfluss. Hier wurden beide Brüste in die Studie eingeschlossen, so dass insgesamt 56 Fälle mit einem Durchschnittsalter von 51,2 Jahren (Standardabweichung ± 12,8 Jahre, Median 52,5 Jahre) betrachtet wurden. Ältere Patientinnen zeigten dabei häufiger maligne Ursachen als jüngere, ohne Nachweis eines signifikanten Unterschieds (p = 0,272).
Bei der klinischen Untersuchung war in 44,6% (25/56) ein nicht-blutiger und in 55,4% (31/56) ein blutiger Ausfluss erkennbar. Die Inzidenz der Malignität in der Gruppe der blutigen Sekretion war höher (19,4% vs. 8,0%), jedoch nicht signifikant (p = 0,23). In der Literatur wird davon berichtet, dass bei blutigem Ausfluss das Risiko für ein Mammakarzinom höher ist. Es wird aber auch darauf hingewiesen, dass bei einem nicht-blutigen Ausfluss ein Malignom keinesfalls ausgeschlossen werden kann.
Die häufigste Ursache der pathologischen Mamillensekretion war, wie auch in der Literatur berichtet wird, mit 39,4% ein Papillom. Insgesamt wurde in 14,8% ein Malignom nachgewiesen. Dies ist etwas höher als die vergleichbaren Angaben von 2% - 10% in der Literatur.
Es bestand ein signifikanter, direkt proportionaler Zusammenhang zwischen Größe in der MR-Mammographie und Malignität (p = 0,019). Ein Phänomen, das Liberman et al. ebenfalls beschrieben. Sowohl sie als auch Langer et al. empfehlen somit bei Läsionen, die kleiner als 5 mm sind, aufgrund der geringen Malignomrate auf eine Biopsie zu verzichten. Auch in der vorliegenden Studie waren alle Läsionen < 5 mm benigne.
Zwischen der MR-mammographisch geschätzten Größe und der histopathologisch ermittelten Größe konnte eine signifikant hohe Korrelation gezeigt werden (Korrelationskoeffizient nach Pearson 0,095, p < 0,0001). Dabei wurden die Befunde in der Kernspintomographie tendenziell größer dargestellt. Die gleiche Erfahrung machten auch Son et al. und Schouten van der Velden et al..
Die Ergebnisse der MR-Mammographie wurden mit der danach durchgeführten Galaktographie verglichen. Ein wichtiger Nachteil der Galaktographie zeigte sich in der eingeschränkten Durchführbarkeit. In 23,3% konnte diese nicht erfolgreich beendet werden. In der Literatur wird von ähnlichen Prozentsätzen gesprochen. Zusätzlich erzielten wir im Vergleich zur MR-Mammographie sowohl eine geringere Sensitivität (86% vs. 96%) als auch eine niedrigere Spezifität (33% vs. 70%) für die Galaktographie, was sicherlich auch die Schwierigkeit der Unterscheidung zwischen benignen und malignen Befunden bei einer Galaktographie widerspiegelt. Morrogh et al. verglichen die Galaktographie mit der MR-Mammographie bei 1,5 Tesla ebenfalls bei Patientinnen mit pathologischer Mamillensekretion und negativer Standarddiagnostik. Die von ihnen berichtete Sensitivität von 83% für die MR-Mammographie ist vergleichbar mit der der vorliegenden Studie (75%). Bei 1,5 Tesla erreichten sie allerdings nur eine Spezifität von 62%, die geringer ist als die von uns errechnete Spezifität von 88%. Auch andere Studien referieren eine höhere Spezifität bei höherer Feldstärke.
Um dies allerdings aussagekräftig zu zeigen, muss eine intraindividuelle Studie bei 1,5 Tesla und 3,0 Tesla durchgeführt werden.
Zusammenfassend kann man jedoch sagen, dass die Galaktographie durch die nicht invasive, strahlungsfreie MR-Mammographie bei der Untersuchung von Patientinnen mit pathologischer Mamillensekretion ersetzt werden sollte, insbesondere wenn die Standarddiagnostik keine auffälligen Befunde liefern konnte.
Die 31-P-Magnetresonanz-Spektroskopie (31-P-MRS) ist eine nicht-invasive Methode, welche einen direkten Einblick in den Phospholipid-Haushalt der menschlichen Leber erlaubt. Mit der 31-P-MR-Spektroskopie wurden Spektren von 10 Patienten mit Leberzirrhose sowie von 13 gesunden Probanden in Kombination mit dem Lokalisationsverfahren 3D-CSI und dem Nachbearbeitungsprogramm SLOOP (Spectral Localization with Optimal Pointspread Funktion) gewonnen. Die Ergebnisse dieser Studie ergaben signifikante Unterschiede in den Absolutkonzentrationen der Phospholipide zwischen Patienten mit Leberzirrhose und lebergesunden Probanden.
Background
Elbow imaging is challenging with conventional multidetector computed tomography (MDCT), while cone-beam CT (CBCT) provides superior options. We compared intra-individually CBCT versus MDCT image quality in cadaveric elbows.
Methods
A twin robotic x-ray system with new CBCT mode and a high-resolution clinical MDCT were compared in 16 cadaveric elbows. Both systems were operated with a dedicated low-dose (LD) protocol (equivalent volume CT dose index [CTDI\(_{vol(16 cm)}\)] = 3.3 mGy) and a regular clinical scan dose (RD) protocol (CTDI\(_{vol(16 cm)}\) = 13.8 mGy). Image quality was evaluated by two radiologists (R1 and R2) on a seven-point Likert scale, and estimation of signal intensity in cancellous bone was conducted. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) statistics were used.
Results
The CBCT prototype provided superior subjective image quality compared to MDCT scans (for RD, p ≤ 0.004; for LD, p ≤ 0.001). Image quality was rated very good or excellent in 100% of the cases by both readers for RD CBCT, 100% (R1) and 93.8% (R2) for LD CBCT, 62.6% and 43.8% for RD MDCT, and 0.0% and 0.0% for LD MDCT. Single-measure ICC was 0.95 (95% confidence interval 0.91–0.97; p < 0.001). Software-based assessment supported subjective findings with less “undecided” pixels in CBCT than dose-equivalent MDCT (p < 0.001). No significant difference was found between LD CBCT and RD MDCT.
Conclusions
In cadaveric elbow studies, the tested cone-beam CT prototype delivered superior image quality compared to high-end multidetector CT and showed a potential for considerable dose reduction.
Background
Solitary metastases to the pancreas are rare. Therefore the value of resection in curative intention remains unclear. In the literature there are several promising reports about resection of solitary metastasis to the pancreas mainly of renal origin.
Case presentation
Here we report for the first time on the surgical therapy of a 1.5 cm solitary pancreatic metastasis of an adrenocortical carcinoma. The metastasis occurred almost 6 years after resection of the primary tumor. A partial pancreatoduodenectomy was performed and postoperatively adjuvant mitotane treatment was initiated. During the follow-up of 3 years after surgery no evidence of tumor recurrence occurred.
Conclusion
Resection of pancreatic tumors should be considered, even if the mass is suspicious for metastatic disease including recurrence of adrenocortical cancer.
Purpose
Image acquisition and subsequent manual analysis of cardiac cine MRI is time-consuming. The purpose of this study was to train and evaluate a 3D artificial neural network for semantic segmentation of radially undersampled cardiac MRI to accelerate both scan time and postprocessing.
Methods
A database of Cartesian short-axis MR images of the heart (148,500 images, 484 examinations) was assembled from an openly accessible database and radial undersampling was simulated. A 3D U-Net architecture was pretrained for segmentation of undersampled spatiotemporal cine MRI. Transfer learning was then performed using samples from a second database, comprising 108 non-Cartesian radial cine series of the midventricular myocardium to optimize the performance for authentic data. The performance was evaluated for different levels of undersampling by the Dice similarity coefficient (DSC) with respect to reference labels, as well as by deriving ventricular volumes and myocardial masses.
Results
Without transfer learning, the pretrained model performed moderately on true radial data [maximum number of projections tested, P = 196; DSC = 0.87 (left ventricle), DSC = 0.76 (myocardium), and DSC =0.64 (right ventricle)]. After transfer learning with authentic data, the predictions achieved human level even for high undersampling rates (P = 33, DSC = 0.95, 0.87, and 0.93) without significant difference compared with segmentations derived from fully sampled data.
Conclusion
A 3D U-Net architecture can be used for semantic segmentation of radially undersampled cine acquisitions, achieving a performance comparable with human experts in fully sampled data. This approach can jointly accelerate time-consuming cine image acquisition and cumbersome manual image analysis.
Background
Lipoblastoma is a rare benign mesenchymal neoplasm of infancy that most commonly occurs on the extremities and trunk but can arise at variable sites of the body. Retroperitoneal lipoblastomas are particularly rare but can grow to enormous size, and preoperative diagnosis is difficult with diverse, mostly malignant differential diagnoses that would lead to aggressive therapy. Since lipoblastoma is a benign tumor that has an excellent prognosis after resection, correct diagnosis is crucial.
Case presentation
A case of a large retroperitoneal tumor of a 24-month old infant that was clinically suspicious of a malignant tumor is presented. Due to proximity to the right kidney, clinically most probably a nephroblastoma or clear cell sarcoma of the kidney was suspected. Radiological findings were ambiguous. Therefore, the mass was biopsied, and histology revealed an adipocytic lesion. Although mostly composed of mature adipocytes, in view of the age of the patient, the differential diagnosis of a (maturing) lipoblastoma was raised, which was supported by molecular analysis demonstrating a HAS2-PLAG1 fusion. The tumor was completely resected, and further histopathological workup led to the final diagnosis of a 13 cm large retroperitoneal maturing lipoblastoma. The child recovered promptly from surgery and showed no evidence of recurrence so far.
Conclusion
Although rare, lipoblastoma should be included in the differential diagnoses of retroperitoneal tumors in infants and children, and molecular diagnostic approaches could be a helpful diagnostic adjunct in challenging cases.
In den letzten Jahren hat die myokardiale MR-Perfusionsbildgebung als nichtinvasives Verfahren zur Darstellung von funktionellen Veränderungen des Myokards für die Diagnostik der KHK zunehmend an Bedeutung gewonnen. Während in den letzten 20 Jahren die kardiale MRT überwiegend bei einer Magnetfeldstärke von 1,5 T durchge-führt wurde und dies auch immer noch wird, findet aktuell eine rasante Verbreitung von MR-Systemen höherer Feldstärken statt. Von der neuen Hochfeldtechnik erhofft man sich vor allem, je nach Anwendung, eine deutliche Verbesserung der Bildqualität mit höherer räumlicher und zeitlicher Auflösung, wodurch der diagnostische Nutzen noch weiter gesteigert werden könnte.
In der vorliegenden Arbeit wurden mittels First-Pass-MR-Bildgebung bei einer Magnet-feldstärke von 3 T quantitative Werte für die myokardiale Perfusion von 20 gesunden Probanden unter Ruhebedingungen bestimmt.
Sowohl die erhobenen absoluten Perfusionswerte (0,859 ml/g/min im Mittel) als auch die Standardabweichung des mittleren MBF (0,298 ml/g/min) entsprechen den Messungen aus den früheren Publikationen dieser Arbeitsgruppe. In der Gesamtzusammenschau bisher veröffentlichter Perfusionsstudien zeigt sich eine relativ große Variabilität der publizierten Ruheflüsse. Dabei liegt der absolute MBF dieser Arbeit im mittleren Wertebereich dieser Streubreite. Er lässt sich auch mit den in PET-Studien ermittelten Ergebnissen in Einklang bringen, welche als Goldstandard zur Bestimmung der absoluten myokardialen Perfusion beim Menschen gelten.
Die vorliegende Arbeit bestätigt die bereits in anderen 3 T-Studien untersuchten Vorteile der Hochfeld-MRT. Die höhere Magnetfeldstärke ermöglicht durch das größere SNR eine signifikant bessere räumliche Auflösung und besticht vor allem durch die hohe Bildqualität. Dies könnte bei der Erkennung kleiner, subendokardial gelegener Perfusionsdefekte sowie der Erstellung von transmuralen Perfusionsgradienten von Bedeutung sein und verspricht neben einer Reduktion von Partialvolumeneffekten auch eine Verminderung von „dark rim“-Artefakten.
Um diese Vorteile entsprechend nutzen zu können, wird die Entwicklung von Methoden zur pixelweisen Bestimmung der absoluten Flüsse und farblich kodierten Darstellung derselben in Form von Perfusionskarten ein weiterer Schritt in Richtung klinisch einsetzbare Diagnostik sein. Eine Voraussetzung hierfür ist die Entwicklung einer exakten und sehr stabilen Bewegungskorrektur in weiterführenden Studien.
Durch den Wechsel zu einer höheren Magnetfeldstärke von 3 T und den sich daraus ergebenden Vorteilen kann das Potential der MR-Perfusionsbildgebung, insbesondere der Bestimmung quantitativer Perfusionswerte, im Bereich der nichtinvasiven KHK-Diagnostik zukünftig weiter gesteigert werden.
In der Diagnostik und Therapie der KHK sind das frühzeitige Erkennen und die Beurteilung funktioneller Folgen atherosklerotischer Veränderungen von großer Bedeutung. Die First-Pass MR-Bildgebung ermöglicht Aussagen über die myokardiale Perfusion und damit die hämodynamische Relevanz einer Koronarstenose. In der vorliegenden Arbeit wurden quantitative Werte für die myokardiale Durchblutung gesunder Probanden unter Adenosin-induziertem Stress und in Ruhe unter Einsatz der Präbolustechnik bestimmt. Eine exakte Darstellung der arteriellen Inputfunktion wurde durch einen Kontrastmittelbolus in niedriger Dosierung erreicht, die Verwendung höherer Kontrastmitteldosen führte dagegen zu einem verbesserten Signal-zu-Rausch-Verhältnis im Myokard. Die Absolutwerte der myokardialen Perfusion unter Stressbedingungen und in Ruhe wie auch die myokardiale Perfusionsreserve zeigten vergleichbare Mittelwerte, wiesen aber eine geringere Streubreite im Vergleich zu früheren MR Studien auf und waren vergleichbar mit in PET-Studien erzielten Ergebnissen. Weiterhin wurden unter Verwendung dieser Methode Werte für das myokardiale Verteilungsvolumen des Kontrastmittels als wichtiger Parameter in der Differenzierung von gesundem und infarziertem Herzmuskelgewebe ermittelt und die Laufzeit der Boluspassage nach Injektion in Ruhe und unter Stress bestimmt, die zur Unterscheidung von antegrad perfundiertem und von über Kollateralen versorgtem Myokard dienen kann. Mit Hilfe der MRT war es auch möglich, Unterschiede zwischen subendo- und subepimyokardialer Perfusion zu quantifizieren. Die erzielten Ergebnisse entsprechen bisher publizierten Werten, die mit anderen Modalitäten gewonnen wurden. Der Vergleich der absoluten Perfusion bei verminderter zeitlicher Auflösung mit den bei hoher zeitlicher Auflösung gemessenen Werten ergab nur geringfügige Abweichungen der Ergebnisse voneinander. Dadurch eröffnet sich die Möglichkeit, durch die Zeitersparnis mehrere Schichten abwechselnd bei verschiedenen Herzschlägen zu messen und damit eine erweiterte Abdeckung des linksventrikulären Myokards zu erreichen. Durch die quantitative Auswertung der First-Pass MR-Perfusionsmessung stellt die beschriebene Methode eine vielversprechende Option im Bereich der nichtinvasiven Diagnostik verschiedener myokardialer Erkrankungen dar.
This work deals with the acceleration of cardiovascular MRI for the assessment
of functional information in steady-state contrast and for viability assessment
during the inversion recovery of the magnetization. Two approaches
are introduced and discussed in detail. MOCO-MAP uses an exponential
model to recover dynamic image data, IR-CRISPI, with its low-rank plus
sparse reconstruction, is related to compressed sensing.
MOCO-MAP is a successor to model-based acceleration of parametermapping
(MAP) for the application in the myocardial region. To this end, it
was augmented with a motion correction (MOCO) step to allow exponential
fitting the signal of a still object in temporal direction. Iteratively, this
introduction of prior physical knowledge together with the enforcement of
consistency with the measured data can be used to reconstruct an image
series from distinctly shorter sampling time than the standard exam (< 3 s
opposed to about 10 s). Results show feasibility of the method as well as
detectability of delayed enhancement in the myocardium, but also significant
discrepancies when imaging cardiac function and artifacts caused already by
minor inaccuracy of the motion correction.
IR-CRISPI was developed from CRISPI, which is a real-time protocol
specifically designed for functional evaluation of image data in steady-state
contrast. With a reconstruction based on the separate calculation of low-rank
and sparse part, it employs a softer constraint than the strict exponential
model, which was possible due to sufficient temporal sampling density via
spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on
dynamic and on inversion recovery data. Thus, motion correction is rendered
unnecessary with it.
IR-CRISPI was equipped with noise suppression via spatial wavelet filtering.
A study comprising 10 patients with cardiac disease show medical
applicability. A comparison with performed traditional reference exams offer
insight into diagnostic benefits. Especially regarding patients with difficulty
to hold their breath, the real-time manner of the IR-CRISPI acquisition provides
a valuable alternative and an increase in robustness.
In conclusion, especially with IR-CRISPI in free breathing, a major acceleration
of the cardiovascular MR exam could be realized. In an acquisition
of less than 100 s, it not only includes the information of two traditional
protocols (cine and LGE), which take up more than 9.6 min, but also allows
adjustment of TI in retrospect and yields lower artifact level with similar
image quality.
Introduction
In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities.
Materials and methods
Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded.
Results
Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up.
Conclusions
Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury.
Objectives
Open-access cancer imaging datasets have become integral for evaluating novel AI approaches in radiology. However, their use in quantitative analysis with radiomics features presents unique challenges, such as incomplete documentation, low visibility, non-uniform data formats, data inhomogeneity, and complex preprocessing. These issues may cause problems with reproducibility and standardization in radiomics studies.
Methods
We systematically reviewed imaging datasets with public copyright licenses, published up to March 2023 across four large online cancer imaging archives. We included only datasets with tomographic images (CT, MRI, or PET), segmentations, and clinical annotations, specifically identifying those suitable for radiomics research. Reproducible preprocessing and feature extraction were performed for each dataset to enable their easy reuse.
Results
We discovered 29 datasets with corresponding segmentations and labels in the form of health outcomes, tumor pathology, staging, imaging-based scores, genetic markers, or repeated imaging. We compiled a repository encompassing 10,354 patients and 49,515 scans. Of the 29 datasets, 15 were licensed under Creative Commons licenses, allowing both non-commercial and commercial usage and redistribution, while others featured custom or restricted licenses. Studies spanned from the early 1990s to 2021, with the majority concluding after 2013. Seven different formats were used for the imaging data. Preprocessing and feature extraction were successfully performed for each dataset.
Conclusion
RadiomicsHub is a comprehensive public repository with radiomics features derived from a systematic review of public cancer imaging datasets. By converting all datasets to a standardized format and ensuring reproducible and traceable processing, RadiomicsHub addresses key reproducibility and standardization challenges in radiomics.
Critical relevance statement
This study critically addresses the challenges associated with locating, preprocessing, and extracting quantitative features from open-access datasets, to facilitate more robust and reliable evaluations of radiomics models.
Key points
- Through a systematic review, we identified 29 cancer imaging datasets suitable for radiomics research.
- A public repository with collection overview and radiomics features, encompassing 10,354 patients and 49,515 scans, was compiled.
- Most datasets can be shared, used, and built upon freely under a Creative Commons license.
- All 29 identified datasets have been converted into a common format to enable reproducible radiomics feature extraction.
Mit steigender Nachfrage an minimal-invasiven Therapieoptionen wächst auch das Interesse an innovativen Alternativen im Bereich des arteriellen Gefäßverschlusses nach PVI. Ziel der vorliegenden Arbeit war es, die Effektivität und Sicherheit eines neu auf dem Markt befindlichen, Doppelclip-basierten aktiven VVS zu prüfen. Eine hohe technische Erfolgsrate von 98,8 % bei einer geringen Komplikationsrate von 3,6 % wurde verzeichnet. Bei Anwesenheit der Komorbiditäten Dm und CNI 5 zeigte sich eine signifikante Assoziation zu einem vermehrten Auftreten von Komplikationen. Ein nachgewiesener signifikanter Zusammenhang bestand zudem zwischen einem erhöhten Kalzifikationsgrad der Punktionsstelle bei Vorliegen einer pAVK und eines Dm. Eine erhöhte Gefäßrigidität aufgrund von Komorbiditäten und vaskulären Kalzifikationen, intrinsische Fremdkörperreaktionen, vasoregulatorische Reaktionen oder Produktversagen bieten hypothetische Erklärungsansätze für die einzelnen komplikativen Fälle. Die Nutzung des VVS in spezifischen, bisher nicht beschriebenen Situationen (Unterdimensionierung, Anwendung nach Gefäßpunktionen mit Zugangsschleusen bis 9F, antegrade Punktionsrichtung, anspruchsvolle Eingriffe multimorbider Patienten mit komplexem vaskulärem Status) erwies sich als suffizient. Zur Prävention schwerwiegender Komplikationen während zukünftiger Interventionen wurden die Empfehlung ausgesprochen, eine Durchleuchtungsaufnahme zur Lagekontrolle vor Implantation des proximalen Clips anzufertigen. Eine speziell für Gefäßverschlüsse nach antegrader Punktion konzipierte Zugangsschleuse könnte das Abknicken von Zugangsschleusen bei VVS Applikation verhindern. Zusammenfassend kann das untersuchte aktive VVS mit einzigartigem Wirkmechanismus und spezifischen Design als effektiv und sicher angesehen werden.
This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images. For image quality assessment, contrast-to-noise ratios (CNRs) were calculated, and subjective evaluation (overall quality, luminal contrast, vessel sharpness, blooming, and beam hardening) was performed independently by three radiologists. Fifty-seven patients (12 women, 45 men) were included with a median interval between examinations of 12.7 months (interquartile range 11.1 months). Using manufacturer-recommended scan protocols resulted in a substantially lower radiation dose in PCD-CT (size-specific dose estimate: 4.88 ± 0.48 versus 6.28 ± 0.50 mGy, p < 0.001), while CNR was approximately 50% higher (41.11 ± 8.68 versus 27.05 ± 6.73, p < 0.001). Overall image quality and luminal contrast were deemed superior in PCD-CT (p < 0.001). Notably, EID-CT allowed for comparable vessel sharpness (p = 0.439) and less pronounced blooming and beam hardening (p < 0.001). Inter-rater agreement was good to excellent (0.58–0.87). Concluding, aortic PCD-CTAs facilitate increased image quality with significantly lower radiation dose compared to EID-CTAs
Objective:
Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals.
Methods:
Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses.
Results:
In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28% (interquartile range [IQR] 0.17–0.42%) in male and 0.24% (IQR 0.14–0.45%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g).
Conclusions:
The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers.
Purpose
Sacral nerve stimulation is an effective treatment for patients suffering from fecal incontinence. However, less is knownabout predictors of success before stimulation. The purpose of this study was to identify predictors of successful sacral nervestimulation in patients with idiopathic fecal incontinence.
Methods
Consecutive female patients, receiving peripheral nerve evaluation and sacral nerve stimulation between September2008 and October 2014, suffering from idiopathic fecal incontinence were included in this study. Preoperative patient’scharac-teristics, anal manometry, and defecography results were collected prospectively and investigated by retrospective analysis. Mainoutcome measures were independent predictors of treatment success after sacral nerve stimulation.
Results
From, all in all, 54 patients suffering from idiopathic fecal incontinence receiving peripheral nerve evaluation, favorableoutcome was achieved in 23 of 30 patients after sacral nerve stimulation (per protocol 76.7%; intention to treat 42.6%). From allanalyzed characteristics, wide anorectal angle at rest in preoperative defecography was the only independent predictor offavorable outcome in multivariate analysis (favorable 134.1 ± 13.9° versus unfavorable 118.6 ± 17.1°).
Conclusions
Anorectal angle at rest in preoperative defecography might present a predictor of outcome after sacral nervestimulation in patients with idiopathic fecal incontinence.
Multiple myeloma (MM) frequently induces persisting osteolytic manifestations despite hematologic treatment response. This study aimed to establish a biometrically valid study endpoint for bone remineralization through quantitative and qualitative analyses in sequential CT scans. Twenty patients (seven women, 58 ± 8 years) with newly diagnosed MM received standardized induction therapy comprising the anti-SLAMF7 antibody elotuzumab, carfilzomib, lenalidomide, and dexamethasone (E-KRd). All patients underwent whole-body low-dose CT scans before and after six cycles of E-KRd. Two radiologists independently recorded osteolytic lesion sizes, as well as the presence of cortical destruction, pathologic fractures, rim and trabecular sclerosis. Bland–Altman analyses and Krippendorff’s α were employed to assess inter-reader reliability, which was high for lesion size measurement (standard error 1.2 mm) and all qualitative criteria assessed (α ≥ 0.74). After six cycles of E-KRd induction, osteolytic lesion size decreased by 22% (p < 0.001). While lesion size response did not correlate with the initial lesion size at baseline imaging (Pearson’s r = 0.144), logistic regression analysis revealed that the majority of responding osteolyses exhibited trabecular sclerosis (p < 0.001). The sum of osteolytic lesion sizes on sequential CT scans defines a reliable study endpoint to characterize bone remineralization. Patient level response is strongly associated with the presence of trabecular sclerosis.
Hintergrund
Kardiale Magnetresonanztomographie (CMR) kann für den Nachweis und die Bestimmung von Late Gadolinium Enhancement (LGE), mikrovaskulärer Obstruktion (MO) und intramyokardialer Einblutung (IMH) genutzt werden. Die Studie hat zum Ziel, den prognostischen Nutzen dieser drei MRT-Parameter bei der Entwicklung linksventrikulären Remodelings nach Myokardinfarkt (MI) zu evaluieren.
Methoden
Das Studienkollektiv umfasste 55 Patienten (Alter: 56±11 Jahre; Geschlecht: 53 m/2 w), welche nach dem Erstereignis eines Myokardinfarkts durch primäre Koronarintervention therapiert wurden. CMR mit Late Gadolinium Enhancement (LGE), First Pass Perfusion (FPP) und T2 gewichteter (T2w) Turbospinecho-Sequenz wurde 72 Stunden und ein Jahr nach MI durchgeführt. Linksventrikuläres Remodeling wird dabei als Anstieg des enddiastolischen Volumens um ≥ 20% und/oder einem Abfall der Ejektionsfraktion um > 10% definiert.
Ergebnisse
Late Gadolinium Enhancement ist eine effektive Methode, um die Infarktgröße zu bestimmen. Dabei zeigten 77,70 % der Patienten mit linksventrikulärem Remodeling eine Infarktgröße die 20 % der linksventrikulären Masse überschritt. Als ein Teilaspekt der vorliegenden Studie wurden die Patienten in drei Gruppen anhand der Ergebnisse ihrer Koronarintervention unterteilt (RIVA: n= 26; RCA: n= 20; RCX: n = 8). In der Jahresuntersuchung wiesen Patienten mit Vorderwandinfarkt eine niedrigere Ejektionsfraktion, einen signifikanten Anstieg des enddiastolischen Volumens und eine größere Infarktgröße als Probanden mit anderen Infarktlokalisationen auf. Ungefähr die Hälfte aller Remodelingpatienten erlitt einen Verschluss der RIVA.
Mikrovaskuläre Obstruktion kann sowohl in der LGE Sequenz, als auch in der First Pass Perfusion nachgewiesen werden. In dieser Studie zeigt sich, dass die Größe der MO in der LGE Sequenz 80 % kleiner als in der FPP ausfiel. Dennoch besitzt die Anwesenheit der MO in der LGE Sequenz den größeren prognostischen Wert, da hier vor allem die ausgeprägten Areale der mikrovaskulären Obstruktion zur Darstellung kommen und Patienten mit diesen gefährdeter sind, ventrikuläres Remodeling zu entwickeln. Patienten mit MO (= MO (+)) (FPP: n= 42; LGE: n=27) besaßen eine kleinere Ejektionsfraktion (20 %), ein größeres enddiastolisches Volumen (24 %) und größere Infarktareale (170 %) in der Jahreskontrolle als Patienten ohne MO (= MO (-))
Intramyokardiale Einblutung wurde bei 29 Patienten (= IMH (+)) beobachtet, welche eine niedrige Ejektionsfraktion (17 %), ein höheres enddiastolisches Volumen (19 %) und eine größere Infarktgröße (180 %) als Patienten ohne IMH (= IMH (-)) nach einem Jahr aufwiesen. IMH fand sich in 72,15% der Patienten mit linksventrikulärem Remodeling.
Zusammenfassung
Late Gadolinium Enhancement, mikrovaskuläre Obstruktion und intramyokardiale Einblutung können zur Vorhersage linksventrikulären Remodelings bei Patienten nach Myokardinfarkt verwendet werden. In der vorliegenden Studie waren der Nachweis von MO in der LGE Sequenz und die Anwesenheit von IMH in der T2-Bildgebung die aussagekräftigsten prognostischen Faktoren.
Purpose
Machine learning based on radiomics features has seen huge success in a variety of clinical applications. However, the need for standardization and reproducibility has been increasingly recognized as a necessary step for future clinical translation. We developed a novel, intuitive open-source framework to facilitate all data analysis steps of a radiomics workflow in an easy and reproducible manner and evaluated it by reproducing classification results in eight available open-source datasets from different clinical entities.
Methods
The framework performs image preprocessing, feature extraction, feature selection, modeling, and model evaluation, and can automatically choose the optimal parameters for a given task. All analysis steps can be reproduced with a web application, which offers an interactive user interface and does not require programming skills. We evaluated our method in seven different clinical applications using eight public datasets: six datasets from the recently published WORC database, and two prostate MRI datasets—Prostate MRI and Ultrasound With Pathology and Coordinates of Tracked Biopsy (Prostate-UCLA) and PROSTATEx.
Results
In the analyzed datasets, AutoRadiomics successfully created and optimized models using radiomics features. For WORC datasets, we achieved AUCs ranging from 0.56 for lung melanoma metastases detection to 0.93 for liposarcoma detection and thereby managed to replicate the previously reported results. No significant overfitting between training and test sets was observed. For the prostate cancer detection task, results were better in the PROSTATEx dataset (AUC = 0.73 for prostate and 0.72 for lesion mask) than in the Prostate-UCLA dataset (AUC 0.61 for prostate and 0.65 for lesion mask), with external validation results varying from AUC = 0.51 to AUC = 0.77.
Conclusion
AutoRadiomics is a robust tool for radiomic studies, which can be used as a comprehensive solution, one of the analysis steps, or an exploratory tool. Its wide applicability was confirmed by the results obtained in the diverse analyzed datasets. The framework, as well as code for this analysis, are publicly available under https://github.com/pwoznicki/AutoRadiomics.
Purpose
Inhomogeneities of the static magnetic B\(_{0}\) field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B\(_{0}\)‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B\(_{0}\) variations are measured, and a methodology for spherical harmonics shimming of the B\(_{0}\) field within the human myocardium is proposed.
Methods
The spatial B\(_{0}\)‐field distribution in the heart was analyzed as well as temporal B\(_{0}\)‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B\(_{0}\) shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.
Results
The strongest B\(_{0}\)‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B\(_{0}\)‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B\(_{0}\)‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.
Conclusion
Challenges in state‐of‐the‐art B\(_{0}\) shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.
In der vorliegenden Arbeit wurde die myokardiale Perfusion gesunder Probanden in Ruhe und unter Adenosin–induziertem, sowie Kälte-induziertem Stress quantitativ mittels First-Pass-Perfusions MR-Bildgebung beim gleichen Probanden untersucht und die Perfusionswerte alters- und geschlechtsabhängig verglichen. Hierbei wurden zwanzig Probanden in altersabhängige Gruppen eingeteilt, wobei der cut-off vierzig Jahre war. Diese Arbeit zeigt, dass der Einsatz des CPT zur Beurteilung der endothelvermittelten Vasodilatation im MRT möglich ist. Im Vergleich zum Einsatz von Adenosin zeigt die Stress-Untersuchung mittels CPT weniger bis keine unerwünschten Nebenwirkungen und die Kontraindikationen sind geringer. Somit ist der Einsatz des CPT zur Beurteilung der myokardialen Stressperfusion als eine nebenwirkungsarme Untersuchungsmodalität anzusehen, die es ermöglicht, die frühesten Veränderungen des Endothels bei beginnender koronarer Arteriosklerose zu detektieren. Als Ergebnis ist festzuhalten, dass in dieser Arbeit alle Probanden eine statistisch signifikante Perfusionserhöhung beim CPT aufweisen. Es zeigt sich kein statistisch signifikanter Alters- oder Geschlechtsunterschied beim CPT. Auf die Verabreichung von Adenosin reagiert die junge Probandengruppe mit einer statistisch signifikant höheren Myokardperfusion. Dies könnte in erster Linie durch den höheren Anteil an Frauen in der jungen Gruppe zu erklären sein.
Background:
Ketogenic diets (KDs) or short-term fasting are popular trends amongst supportive approaches for cancer patients. Beta-hydroxybutyrate (3-OHB) is the main physiological ketone body, whose concentration can reach plasma levels of 2–6 mM during KDs or fasting. The impact of 3-OHB on the biology of tumor cells described so far is contradictory. Therefore, we investigated the effect of a physiological concentration of 3 mM 3-OHB on metabolism, proliferation, and viability of breast cancer (BC) cells in vitro.
Methods:
Seven different human BC cell lines (BT20, BT474, HBL100, MCF-7, MDA-MB 231, MDA-MB 468, and T47D) were cultured in medium with 5 mM glucose in the presence of 3 mM 3-OHB at mild hypoxia (5% oxygen) or normoxia (21% oxygen). Metabolic profiling was performed by quantification of the turnover of glucose, lactate, and 3-OHB and by Seahorse metabolic flux analysis. Expression of key enzymes of ketolysis as well as the main monocarboxylic acid transporter MCT2 and the glucose-transporter GLUT1 was analyzed by RT-qPCR and Western blotting. The effect of 3-OHB on short- and long-term cell proliferation as well as chemo- and radiosensitivity were also analyzed.
Results:
3-OHB significantly changed the oxygen consumption rate (OCR) and extracellular acidification rate (ECAR) in BT20 cells resulting in a more oxidative energetic phenotype. MCF-7 and MDA-MB 468 cells had increased ECAR only in response to 3-OHB, while the other three cell types remained uninfluenced. All cells expressed MCT2 and GLUT1, thus being able to uptake the metabolites. The consumption of 3-OHB was not strongly linked to mRNA overexpression of key enzymes of ketolysis and did not correlate with lactate production and glucose consumption. Neither 3-OHB nor acetoacetate did interfere with proliferation. Further, 3-OHB incubation did not modify the response of the tested BC cell lines to chemotherapy or radiation.
Conclusions:
We found that a physiological level of 3-OHB can change the energetic profile of some BC cell lines. However, 3-OHB failed to influence different biologic processes in these cells, e.g., cell proliferation and the response to common breast cancer chemotherapy and radiotherapy. Thus, we have no evidence that 3-OHB generally influences the biology of breast cancer cells in vitro.
In der vorliegenden prospektiven experimentellen Studie wurden jeweils 18 Probanden sowie Patienten, die unter einer genetisch gesicherten Friedrich-Ataxie leiden, mit der Tissue-Phase‐Mapping (TPM) Sequenz im MRT untersucht. Mit der erwähnten Sequenz ist es möglich, die Geschwindigkeit der Herzwandbewegung über einen Herzzyklus zeitlich hoch aufgelöst (13,8 ms) darzustellen. Es wurde in der Vergangenheit gezeigt, dass die Daten der TPM‐Messung reproduzierbar sowie mit denen aus einer Ultraschalluntersuchung gewonnenen Daten vergleichbar sind. Die Aufnahme erfolgt unter freier Atmung in Navigatortechnik. Dadurch ist diese Untersuchung auch bei Patienten möglich, die aufgrund Ihrer Erkrankung sonst nicht ausreichend lange die Luft anhalten könnten. Die Friedreich‐Ataxie ist die häufigste aller Ataxien in der Adoleszenzphase und wird autosomal-rezessiv vererbt. Neben neurologischen Ausfällen kann es auch zu einer kardialen Beteiligung kommen. Dabei zeigt sich bei einem großen Teil der Patienten eine Kardiomyopathie mit asymmetrischer septaler Hypertrophie sowie einer dynamischen linksventrikulären Ausflussobstruktion. Die American Heart Association klassifiziert dieses Krankeitsbild als sekundäre Kardiomyopathie neuromuskulären Ursprungs. Es wurde in der Vergangenheit bereits gezeigt, dass es unter einer Therapie mit dem Medikament Idebenone zu einer Verbesserung der kardialen Funktion kommen kann. Im Zusammenhang mit einer groß angelegten, multizentrischen Phase III Studie (MICONOS-Studie) kamen diese Patienten nach Würzburg für eine MRT-Untersuchung. Im Rahmen dessen erfolgte dann auf freiwilliger Basis eine Untersuchung mit der TPM-Sequenz. Diese Substudie wurde von der lokalen Ethikkommission genehmigt und die Patienten wie auch Probanden haben selbst oder durch Erziehungsberechtigte der Untersuchung zugestimmt. Es konnte durch diese Arbeit gezeigt werden, dass zum einen die Methode des Tissue-Phase‐Mappings erfolgreich am Institut für Röntgendiagnostik des Universitätsklinikums Würzburg eingeführt werden konnte. Zum anderen, dass die Ergebnisse der herzgesunden Probanden mit anderen, in der Vergangenheit durchgeführten Studien, ähnlich und vergleichbar sind. Zudem konnten teilweise signifikante Unterschiede der systolischen wie auch der diastolischen Geschwindigkeiten zwischen Probanden und Patienten der MICONOS Studie in einigen ROIs bzw. global nachgewiesen werden. Dies bedeutet, dass das hier vorgestellte Verfahren in der Lage ist, Unterschiede in den Geschwindigkeiten der regionalen wie auch globalen Herzwandbewegung in allen drei Bewegungsachsen zwischen verschiedenen Kollektiven zu detektieren. Diese Differenzen können ein Frühzeichen für eine pathologische Herzmuskelerkrankung sein und somit helfen, dass frühzeitig eine entsprechende Therapie begonnen wird. Aufgrund der Ergebnisse dieser Dissertation werden weitere Studien folgen, die helfen werden, dass das Tissue-Phase‐Mapping Verfahren Einzug in die klinische Routine erhalten wird.
Functional magnetic resonance imaging (fMRI) has become a powerful and influential method to non-invasively study neuronal brain activity. For this purpose, the blood oxygenation level-dependent (BOLD) effect is most widely used. T2* weighted echo planar imaging (EPI) is BOLD sensitive and the prevailing fMRI acquisition technique. Here, we present an alternative to its standard Cartesian recordings, i.e. k-space density weighted EPI, which is expected to increase the signal-to-noise ratio in fMRI data. Based on in vitro and in vivo pilot measurements, we show that fMRI by k-space density weighted EPI is feasible and that this new acquisition technique in fact boosted spatial and temporal SNR as well as the detection of local fMRI activations. Spatial resolution, spatial response function and echo time were identical for density weighted and conventional Cartesian EPI. The signal-to-noise ratio gain of density weighting can improve activation detection and has the potential to further increase the sensitivity of fMRI investigations.
Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words “brain”, “metastas*”, “tumor”, “colorectal”, “cancer”, and “malignancy”. In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1% and 11.5%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment.
Purpose
The AMADEUS (Area Measurement And DEpth and Underlying Structures) scoring and grading system has been proposed for the MRI based evaluation of untreated focal chondral defects around the knee. The clinical practicability, its correlation with arthroscopically assessed grading systems (ICRS – International Cartilage Repair Society) and thereby its clinical value in terms of decision making and guiding prognosis was yet to determine.
Methods
From 2008 to 2019 a total of 89 individuals were indicated for high tibial valgus osteotomy (HTO) due to tibial varus deformity and concomitant chondral defects of the medial compartment of the knee. All patients received a preoperative MRI (1.5 Tesla or 3.0 Tesla) and pre-osteotomy diagnostic arthroscopy. Chondral defects of the medial compartment were scored and graded with the MRI based AMADEUS by three independent raters and compared to arthroscopic defect grading by the ICRS system. Interrater and intrarater reliability as well as correlation analysis with the ICRS classification system were assessed.
Results
Intraclass correlation coefficients for the various subscores of the AMADEUS showed an overall good to excellent interrater agreement (min: 0.26, max: 0.80). Intrarater agreement turned out to be substantially inferior (min: 0.08, max: 0.53). Spearman correlation revealed an overall moderate correlative association of the AMADEUS subscores with the ICRS classification system, apart from the defect area subscore. Sensitivity of the AMADEUS to accurately identify defect severity according to the ICRS was 0.7 (0.69 for 3.0 Tesla MRI, 0.67 for 1.5 Tesla MRI). The mean AMADEUS grade was 2.60 ± 0.81 and the mean ICRS score 2.90 ± 0.63.
Conclusions
Overall, the AMADEUS with all its subscores shows moderate correlation with the arthroscopic chondral grading system according to ICRS. This suggests that chondral defect grading by means of the MRI based AMADEUS is well capable of influencing and guiding treatment decisions. Interrater reliability shows overall good agreement.
We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.
One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical …
Parathyroid carcinoma (PC) is an orphan malignancy accounting for only ~1% of all cases with primary hyperparathyroidism. The localization of recurrent PC is of critical importance and can be exceedingly difficult to diagnose and sometimes futile when common sites of recurrence in the neck and chest cannot be confirmed. Here, we present the diagnostic workup, molecular analysis and multimodal therapy of a 46-year old woman with the extraordinary manifestation of abdominal lymph node metastases 12 years after primary diagnosis of PC. The patient was referred to our endocrine tumor center in 2016 with the aim to localize the tumor causative of symptomatic biochemical recurrence. In view of the extensive previous workup we decided to perform [18F]FDG-PET-CT. A pathological lymph node in the liver hilus showed slightly increased FDG-uptake and hence was suspected as site of recurrence. Selective venous sampling confirmed increased parathyroid hormone concentration in liver veins. Abdominal lymph node metastasis was resected and histopathological examination confirmed PC. Within four months, the patient experienced biochemical recurrence and based on high tumor mutational burden detected in the surgical specimen by whole exome sequencing the patient received immunotherapy with pembrolizumab that led to a biochemical response. Subsequent to disease progression repeated abdominal lymph node resection was performed in 10/2018, 01/2019 and in 01/2020. Up to now (12/2020) the patient is biochemically free of disease. In conclusion, a multimodal diagnostic approach and therapy in an interdisciplinary setting is needed for patients with rare endocrine tumors. Molecular analyses may inform additional treatment options including checkpoint inhibitors such as pembrolizumab.
The occurrence of different subtypes of endogenous Cushing’s syndrome (CS) in single individuals is extremely rare. We here present the case of a female patient who was successfully cured from adrenal CS 4 years before being diagnosed with Cushing’s disease (CD). The patient was diagnosed at the age of 50 with ACTH-independent CS and a left-sided adrenal adenoma, in January 2015. After adrenalectomy and histopathological confirmation of a cortisol-producing adrenocortical adenoma, biochemical hypercortisolism and clinical symptoms significantly improved. However, starting from 2018, the patient again developed signs and symptoms of recurrent CS. Subsequent biochemical and radiological workup suggested the presence of ACTH-dependent CS along with a pituitary microadenoma. The patient underwent successful transsphenoidal adenomectomy, and both postoperative adrenal insufficiency and histopathological workup confirmed the diagnosis of CD. Exome sequencing excluded a causative germline mutation but showed somatic mutations of the β-catenin protein gene (CTNNB1) in the adrenal adenoma, and of both the ubiquitin specific peptidase 8 (USP8) and the glucocorticoid receptor (NR3C1) genes in the pituitary adenoma. In conclusion, our case illustrates that both ACTH-independent and ACTH-dependent CS may develop in a single individual even without evidence for a common genetic background.
Background:
Clinical reasoning in Neurology is based on general associations which help to deduce the site of the lesion. However, even “golden principles” may occasionally be deceptive. Here, we describe the case of subacute flaccid tetraparesis due to motor cortical lesions. To our knowledge, this is the first report to include an impressive illustration of nearly symmetric motor cortical involvement of encephalitis on brain MRI.
Case presentation:
A 51 year old immunocompromized man developed a high-grade pure motor flaccid tetraparesis over few days. Based on clinical presentation, critical illness polyneuromyopathy was suspected. However, brain MRI revealed symmetrical hyperintensities strictly limited to the subcortical precentral gyrus. An encephalitis, possibly due to CMV infection, turned out to be the most likely cause.
Conclusion:
While recognition of basic clinical patterns is indispensable in neurological reasoning, awareness of central conditions mimicking peripheral nervous disease may be crucial to detect unsuspected, potentially treatable conditions.
Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with \(^{18}\)F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUV\(_{max}\), SUV\(_{peak}\), SUV\(_{mean}\)) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50%). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUV\(_{max}\) and SUV\(_{peak}\) compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUV\(_{max}\), p = 0.07; SUV\(_{peak}\), p = 0.08). SUV\(_{mean}\) (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in \(^{18}\)F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUV\(_{mean}\) and TL-PSMA in contrast to PSMA-TV.
Background:
Vascular damage in polytrauma patients is associated with high mortality and morbidity. Therefore, specific clinical implications of vascular damage with fractures in major trauma patients are reassessed.
Methods:
This comprehensive nine-year retrospective single center cohort study analyzed demography, laboratory, treatment and outcome data from 3689 patients, 64 patients with fracture-associated vascular injuries were identified and were compared to a control group.
Results:
Vascular damage occurred in 7% of patients with upper and lower limb and pelvic fractures admitted to the trauma room. Overall survival was 80% in pelvic fracture and 97% in extremity fracture patients and comparable to non-vascular trauma patients. Additional arterial damage required substantial fluid administration and was visible as significantly anemia and disturbed coagulation tests upon admission. Open procedures were done in over 80% of peripheral extremity vascular damage. Endovascular procedures were predominant (87%) in pelvic injury.
Conclusion:
Vascular damage is associated with high mortality rates especially in combination with pelvic fractures. Initial anemia, disturbed coagulation tests and the need for extensive pre-clinical fluid substitution were observed in the cohort with vascular damage. Therefore, fast diagnosis and early interventional and surgical procedures are necessary to optimize patient-specific outcome.
Aims Acute myocardial infarction (MI) is the major cause of chronic heart failure. The activity of blood coagulation factor XIII (FXIIIa) plays an important role in rodents as a healing factor after MI, whereas its role in healing and remodelling processes in humans remains unclear. We prospectively evaluated the relevance of FXIIIa after acute MI as a potential early prognostic marker for adequate healing.
Methods and results This monocentric prospective cohort study investigated cardiac remodelling in patients with ST-elevation MI and followed them up for 1 year. Serum FXIIIa was serially assessed during the first 9 days after MI and after 2, 6, and 12 months. Cardiac magnetic resonance imaging was performed within 4 days after MI (Scan 1), after 7 to 9 days (Scan 2), and after 12 months (Scan 3). The FXIII valine-to-leucine (V34L) single-nucleotide polymorphism rs5985 was genotyped. One hundred forty-six patients were investigated (mean age 58 ± 11 years, 13% women). Median FXIIIa was 118 % (quartiles, 102–132%) and dropped to a trough on the second day after MI: 109%(98–109%; P < 0.001). FXIIIa recovered slowly over time, reaching the baseline level after 2 to 6 months and surpassed baseline levels only after 12 months: 124 % (110–142%). The development of FXIIIa after MI was independent of the genotype. FXIIIa on Day 2 was strongly and inversely associated with the relative size of MI in Scan 1 (Spearman’s ρ = –0.31; P = 0.01) and Scan 3 (ρ = –0.39; P < 0.01) and positively associated with left ventricular ejection fraction: ρ = 0.32 (P < 0.01) and ρ = 0.24 (P = 0.04), respectively.
Conclusions FXIII activity after MI is highly dynamic, exhibiting a significant decline in the early healing period, with reconstitution 6 months later. Depressed FXIIIa early after MI predicted a greater size of MI and lower left ventricular ejection fraction after 1 year. The clinical relevance of these findings awaits to be tested in a randomized trial.
Background
To analyze the benefit of color-coded summation images in the assessment of target lumen perfusion in patients with aortic dissection and malperfusion syndrome before and after fluoroscopy-guided aortic fenestration.
Methods
Between December 2011 and April 2020 25 patients with Stanford type A (n = 13) or type B dissection (n = 12) and malperfusion syndromes were treated with fluoroscopy-guided fenestration of the dissection flap using a re-entry catheter. The procedure was technically successful in 100% of the cases and included additional iliofemoral stent implantation in four patients. Intraprocedural systolic blood pressure measurements for gradient evaluation were performed in 19 cases. Post-processed color-coded DSA images were obtained from all DSA series before and following fenestration. Differences in time to peak (dTTP) values in the compromised aortic lumen and transluminal systolic blood pressure gradients were analyzed retrospectively. Correlation analysis between dTTP and changes in blood pressure gradients was performed.
Results
Mean TTP prior to dissection flap fenestration was 6.85 ± 1.35 s. After fenestration, mean TTP decreased significantly to 4.96 ± 0.94 s (p < 0.001). Available systolic blood pressure gradients between the true and the false lumen were reduced by a median of 4.0 mmHg following fenestration (p = 0.031), with significant reductions in Stanford type B dissections (p = 0.013) and minor reductions in type A dissections (p = 0.530). A moderate correlation with no statistical significance was found between dTTP and the difference in systolic blood pressure (r = 0.226; p = 0.351).
Conclusions
Hemodynamic parameters obtained from color-coded DSA confirmed a significant reduction of TTP values in the aortic target lumen in terms of an improved perfusion in the compromised aortic region. Color-coded DSA might thus be a suitable complementary tool in the assessment of complex vascular patterns prevailing in aortic dissections, especially when blood pressure measurements are not conclusive or feasible.
Background: Endovascular therapy is the gold standard in patients with hemodynamic relevant renal artery stenosis (RAS) resistant to medical therapy. The severity grading of the stenosis as well as the result assessment after endovascular approach is predominantly based on visible estimations of the anatomic appearance. We aim to investigate the application of color-coded DSA parameters to gain hemodynamic information during endovascular renal artery interventions and for the assessment of the procedures technical success.
Methods: We retrospectively evaluated 32 patients who underwent endovascular renal artery revascularization and applied color-coded summation imaging on selected monochromatic DSA images. The differences in time to peak (dTTP) of contrast enhancement in predefined anatomical measuring points were analyzed. Furthermore, differences in systolic blood pressure values (SBP) and serum creatinine were obtained. The value of underlying diabetes mellitus as a predictor for clinical outcome was assessed. Correlation analysis between the patients gender as well as the presence of diabetes mellitus and dTTP was performed.
Results: Endovascular revascularization resulted in statistically significant improvement in 4/7 regions of interest. Highly significant improvement of perfusion in terms of shortened TTP values could be found at the segmental artery level and in the intrastenotical segment (p<0.001), significant improvement prestenotical and in the apical renal parenchyma (p<0.05). In the other anatomic regions, differences revealed not to be significant. Differences between SBP and serum creatinine levels before and after the procedure were significant (p=0.004 and 0.0004). Patients ' gender as well as the presence of diabetes mellitus did not reveal to be predictors for the clinical success of the procedure. Furthermore, diabetes and gender did not show relevant correlation with dTTP in the parenchymal measuring points.
Conclusions: The supplementary use of color-coding DSA and the data gained from parametric images may provide helpful information in the evaluation of the procedures ' technical success. The segmental artery might be a particularly suitable vascular territory for analyzing differences in blood flow characteristics. Further studies with larger cohorts are needed to further confirm the diagnostic value of this technique.
Background
The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy.
Methods
MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman’s rank correlation.
Results
Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01).
Conclusion
The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.
Pulmonary artery embolism (PE) is a common condition and an even more common clinical suspect. The computed tomography pulmonary angiogram (CTPA) is the main medical imaging tool used to diagnose a suspected case of PE. To gain a better impression of the effects of a PE on the perfusion and hence the gas exchange, a functional imaging method is beneficial. One approach for functional imaging using radiation exposure is the generation of color-coded iodine perfusion maps acquired by Dual-Energy Computed Tomography (DECT), which enable the detection of perfusion defects in the pulmonary parenchyma. In contrast to the existing approach of DECT with iodine color-coded maps, the SElf-gated Non-Contrast-Enhanced FUnctional Lung (SENCEFUL) MRI technique offers the possibility to interpret perfusion maps without any radiation exposure or application of contrast agents. The measurement in SENCEFUL MRI can be performed during conditions of free breathing and without electrocardiogram triggering.
The purpose of this study was to determine whether PE can be diagnosed on the basis of visible perfusion defects in the perfusion maps of SENCEFUL MRI and in the iodine-coded maps of DECT and to compare the diagnostic performance of these methods. Both SENCEFUL-MRI and iodine distribution maps from DECT have been compared with the CTPA of ten patients with PE. Additionally, the functional images were compared with each other on a per-patient basis.
The iodine perfusion maps of DECT had a sensitivity of 84.2 % and specificity of 65.2 % for the diagnosis of PE. The SENCEFUL technique in MRI showed a sensitivity of 78.9 % and a specificity of 26.1 %. When comparing the whole lung depicted in both series of functional images, the main perfusion defect location matched in four of ten patients (40 %).
In conclusion, this work found that DECT iodine maps have higher sensitivity and specificity in the diagnosis of pulmonary embolism compared with SENCEFUL MRI.
Background
With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies.
Methods
After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode. Images were reconstructed with dedicated convolution kernels (soft: Body-vascular (Bv)48; sharp: Bv60; ultrasharp: Bv76). Six radiologists evaluated the image quality by means of a pairwise forced-choice comparison tool. Kendall’s concordance coefficient (W) was calculated to quantify interrater agreement. Image quality was further assessed by measuring intraluminal attenuation and image noise as well as by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR).
Results
UHR yielded lower noise than SR for identical reconstructions with kernels ≥ Bv60 (p < 0.001). UHR scans exhibited lower intraluminal attenuation compared to SR (Bv60: 406.4 ± 25.1 versus 418.1 ± 30.1 HU; p < 0.001). Irrespective of scan mode, SNR and CNR decreased while noise increased with sharper kernels but UHR scans were objectively superior to SR nonetheless (Bv60: SNR 25.9 ± 6.4 versus 20.9 ± 5.3; CNR 22.7 ± 5.8 versus 18.4 ± 4.8; p < 0.001). Notably, UHR scans were preferred in subjective assessment when images were reconstructed with the ultrasharp Bv76 kernel, whereas SR was rated superior for Bv60. Interrater agreement was high (W = 0.935).
Conclusions
Combinations of UHR scan mode and ultrasharp convolution kernel are able to exploit the full image quality potential in photon-counting CT angiography of the femoral arteries.
Relevance statement
The UHR scan mode offers improved image quality and may increase diagnostic accuracy in CT angiography of the peripheral arterial runoff when optimized reconstruction parameters are chosen.
Key points
• UHR photon-counting CT improves image quality in combination with ultrasharp convolution kernels.
• UHR datasets display lower image noise compared with identically reconstructed standard resolution scans.
• Scans in UHR mode show decreased intraluminal attenuation compared with standard resolution imaging.
Objectives
We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS).
Methods
The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers. In all specimens, the common femoral and popliteal arteries were prepared, introducer sheaths inserted, and perfusion established by a peristaltic pump. Subsequently, we performed CTA and bilateral DSA in five cadavers and IVUS on both legs of four donors. Examination time without unintentional interruption was measured both with and without non-contrast planning CT. Percutaneous transluminal angioplasty and stenting was performed by two interventional radiologists on nine extremities (five donors) using a broad spectrum of different intravascular devices.
Results
The perfusion of the upper leg arteries was successfully established in all fresh-frozen but not in the formalin-fixed cadaver. The experimental setup generated a stable circulation in each procedure (ten upper legs) for a period of more than six hours. Images acquired with CT, DSA and IVUS offered a realistic impression and enabled the sufficient visualization of all examined vessel segments. Arterial cannulating, percutaneous transluminal angioplasty as well as stent deployment were feasible in a way that is comparable to a vascular intervention in vivo. The perfusion model allowed for introduction and testing of previously not used devices.
Conclusions
The continuous femoral perfusion model can be established with moderate effort, works stable, and is utilizable for medical imaging of the peripheral arterial system using CTA, DSA and IVUS. Therefore, it appears suitable for research studies, developing skills in interventional procedures and testing of new or unfamiliar vascular devices.
Background: Neurologic symptom severity and deterioration at 24 hours (h) predict long-term outcomes in patients with acute large vessel occlusion (LVO) stroke of the anterior circulation. We aimed to examine the association of baseline multiparametric CT imaging and clinical factors with the course of neurologic symptom severity in the first 24 h after endovascular treatment (EVT). Methods: Patients with LVO stroke of the anterior circulation were selected from a prospectively acquired consecutive cohort of patients who underwent multiparametric CT, including non-contrast CT, CT angiography and CT perfusion before EVT. The symptom severity was assessed on admission and after 24 h using the 42-point National Institutes of Health Stroke Scale (NIHSS). Clinical and imaging data were compared between patients with and without early neurological deterioration (END). END was defined as an increase in ≥4 points, and a significant clinical improvement as a decrease in ≥4 points, compared to NIHSS on admission. Multivariate regression analyses were used to determine independent associations of imaging and clinical parameters with NIHSS score increase or decrease in the first 24 h. Results: A total of 211 patients were included, of whom 38 (18.0%) had an END. END was significantly associated with occlusion of the internal carotid artery (odds ratio (OR), 4.25; 95% CI, 1.90–9.47) and the carotid T (OR, 6.34; 95% CI, 2.56–15.71), clot burden score (OR, 0.79; 95% CI, 0.68–0.92) and total ischemic volume (OR, 1.01; 95% CI, 1.00–1.01). In a comprehensive multivariate analysis model including periprocedural parameters and complications after EVT, carotid T occlusion remained independently associated with END, next to reperfusion status and intracranial hemorrhage. Favorable reperfusion status and small ischemic core volume were associated with clinical improvement after 24 h. Conclusions: The use of imaging parameters as a surrogate for early NIHSS progression in an acute LVO stroke after EVT reached limited performance with only carotid T occlusion as an independent predictor of END. Reperfusion status and early complications in terms of intracranial hemorrhage are critical factors that influence patient outcome in the acute stroke phase after EVT.
Darmsonographie bei Kindern – Vergleich von fundamentaler und harmonischer Bildgebung. Ziel: Die harmonische Bildgebung (Harmonic Imaging, HI) wurde eingeführt, um für übergewichtige Erwachsene die Ultraschall-Untersuchung zu verbessern. Inwiefern sie auch für Kinder von Vorteil ist, die aufgrund ihrer physikalischen Eigenschaften bessere Untersuchungsbedingungen als Erwachsene bieten, ist bisher nur wenig untersucht worden. Die vorliegende Arbeit beschäftigt sich mit der Frage, ob mit HI bei der Darmsonographie von Kindern eine Verbesserung gegenüber Fundamental Imaging (FI) eintritt. Material und Methode: Bei 90 Kindern (w:m=46:44) wurden mit einem linearen 7,5MHz- Schallkopf jeweils vier Bildpaare des Darms in fundamentaler und harmonischer Bildgebung (THI- Sonoline Elegra®, Siemens) angefertigt. Die Bilder wurden anhand einer zehnstufigen Skala evaluiert. Zudem wurde der Einfluss von Alter, Geschlecht und BMI-FAP auf die Darstellbarkeit des Darms untersucht und darauf geachtet, ob Darmpathologien wie Wandverdickung und Dilatation vorliegen. Ergebnisse: Bei 17 Patienten wurde jeweils ein Bildpaar ausgeschlossen. Die harmonische Bildgebung war der fundamentalen Bildgebung in allen untersuchten Parametern signifikant überlegen (p<0,001). HI war bei 90 Patienten bei der Wand des Darms 81-mal, beim Lumen des Darms 85-mal und bei der Bildqualität 85-mal FI überlegen. Bei 19 der Kinder wurden Darmpathologien detektiert (15x Dilatation, 2x Wandverdickung und 2x Dilatation+Wandverdickung). Es besteht eine inverse Korrelation zwischen dem BMI-FAP und der Darstellbarkeit des Lumens bzw. der Bildqualität, unabhängig von der verwendeten Methode. Schlussfolgerungen: Bei der Sonographie des Darms im Kindesalter zeigt sich die harmonische Bildgebung der fundamentalen Bildgebung signifikant überlegen. Es sollte daher bei Fragestellungen, die den Darm betreffen, auch in der Pädiatrie bevorzugt Harmonic Imaging angewendet werden.
Die interventionelle radiologische Drainagenbehandlung ist heutzutage ein unverzichtbarer Bestandteil der modernen minimalinvasiven Therapie von Abszessen und infizierten Flüssigkeitsansammlungen. 180 Drainagebehandlungen an 131 Patienten der Chirurgischen Uniklinik Würzburg wurden im Zeitraum von Januar 2001 bis Juli 2003 untersucht. Es werden die beiden angewandten Verfahren der Seldinger- und Trokartechnik beschrieben und nach ihrem Erfolg bewertet. Dargestellt werden zunächst die rein technischen Ergebnisse der Punktionen. Danach werden die Behandlungen im Hinblick auf Erfolg und Misserfolg bewertet. Der Abszess wird bei der Behandlung unterschiedlicher Verhalte besonders berücksichtigt. Verglichen werden die Behandlungserfolge bei septischen Patienten mit denen bei nicht-septischen Patienten. Außerdem wird der Gesundheitszustand von intensivpflichtigen Patienten mithilfe des APACHE III-Scores bewertet.
Das Kraniopharyngeom ist eine dysontogenetische Mittellinienfehlbildung mit raumforderndem Charakter. Die Ätiopathogenese ist noch ungeklärt. Bildgebende Verfahren (Sonographie, MRT) ermöglichen bereits pränatal eine Diagnostik. Das neonatale Kraniopharyngeom ist sehr selten. Bisher finden sich in der Literatur nur wenige Fallberichte von denen operative Verläufe sowie klinische Langzeitverläufe bekannt sind. Es bleibt eine Kontroverse hinsichtlich Radikalität und Zeitpunkt der Operation, nicht aber dahingehend, dass die operationsmikroskopische Versorgung die Therapie der Wahl des neonatalen Kraniopharyngeoms darstellt. Die Nähe zur hypophysären-hypothalamischen Achse bedingt eine hohe Komorbidität der Kinder prä- und postoperativ.
Purpose
To evaluate whether a deep learning model (DLM) could increase the detection sensitivity of radiologists for intracranial aneurysms on CT angiography (CTA) in aneurysmal subarachnoid hemorrhage (aSAH).
Methods
Three different DLMs were trained on CTA datasets of 68 aSAH patients with 79 aneurysms with their outputs being combined applying ensemble learning (DLM-Ens). The DLM-Ens was evaluated on an independent test set of 104 aSAH patients with 126 aneuryms (mean volume 129.2 ± 185.4 mm3, 13.0% at the posterior circulation), which were determined by two radiologists and one neurosurgeon in consensus using CTA and digital subtraction angiography scans. CTA scans of the test set were then presented to three blinded radiologists (reader 1: 13, reader 2: 4, and reader 3: 3 years of experience in diagnostic neuroradiology), who assessed them individually for aneurysms. Detection sensitivities for aneurysms of the readers with and without the assistance of the DLM were compared.
Results
In the test set, the detection sensitivity of the DLM-Ens (85.7%) was comparable to the radiologists (reader 1: 91.2%, reader 2: 86.5%, and reader 3: 86.5%; Fleiss κ of 0.502). DLM-assistance significantly increased the detection sensitivity (reader 1: 97.6%, reader 2: 97.6%,and reader 3: 96.0%; overall P=.024; Fleiss κ of 0.878), especially for secondary aneurysms (88.2% of the additional aneurysms provided by the DLM).
Conclusion
Deep learning significantly improved the detection sensitivity of radiologists for aneurysms in aSAH, especially for secondary aneurysms. It therefore represents a valuable adjunct for physicians to establish an accurate diagnosis in order to optimize patient treatment.
Purpose
Artificial neural networks show promising performance in automatic segmentation of cardiac MRI. However, training requires large amounts of annotated data and generalization to different vendors, field strengths, sequence parameters, and pathologies is limited. Transfer learning addresses this challenge, but specific recommendations regarding type and amount of data required is lacking. In this study, we assess data requirements for transfer learning to experimental cardiac MRI at 7T where the segmentation task can be challenging. In addition, we provide guidelines, tools, and annotated data to enable transfer learning approaches by other researchers and clinicians.
Methods
A publicly available segmentation model was used to annotate a publicly available data set. This labeled data set was subsequently used to train a neural network for segmentation of left ventricle and myocardium in cardiac cine MRI. The network is used as starting point for transfer learning to 7T cine data of healthy volunteers (n = 22; 7873 images) by updating the pre-trained weights. Structured and random data subsets of different sizes were used to systematically assess data requirements for successful transfer learning.
Results
Inconsistencies in the publically available data set were corrected, labels created, and a neural network trained. On 7T cardiac cine images the model pre-trained on public imaging data, acquired at 1.5T and 3T, achieved DICE\(_{LV}\) = 0.835 and DICE\(_{MY}\) = 0.670. Transfer learning using 7T cine data and ImageNet weight initialization improved model performance to DICE\(_{LV}\) = 0.900 and DICE\(_{MY}\) = 0.791. Using only end-systolic and end-diastolic images reduced training data by 90%, with no negative impact on segmentation performance (DICE\(_{LV}\) = 0.908, DICE\(_{MY}\) = 0.805).
Conclusions
This work demonstrates and quantifies the benefits of transfer learning for cardiac cine image segmentation. We provide practical guidelines for researchers planning transfer learning projects in cardiac MRI and make data, models, and code publicly available.
Background
Functional lung MRI techniques are usually associated with time-consuming post-processing, where manual lung segmentation represents the most cumbersome part. The aim of this study was to investigate whether deep learning-based segmentation of lung images which were scanned by a fast UTE sequence exploiting the stack-of-spirals trajectory can provide sufficiently good accuracy for the calculation of functional parameters.
Methods
In this study, lung images were acquired in 20 patients suffering from cystic fibrosis (CF) and 33 healthy volunteers, by a fast UTE sequence with a stack-of-spirals trajectory and a minimum echo-time of 0.05 ms. A convolutional neural network was then trained for semantic lung segmentation using 17,713 2D coronal slices, each paired with a label obtained from manual segmentation. Subsequently, the network was applied to 4920 independent 2D test images and results were compared to a manual segmentation using the Sørensen–Dice similarity coefficient (DSC) and the Hausdorff distance (HD). Obtained lung volumes and fractional ventilation values calculated from both segmentations were compared using Pearson’s correlation coefficient and Bland Altman analysis.
To investigate generalizability to patients outside the CF collective, in particular to those exhibiting larger consolidations inside the lung, the network was additionally applied to UTE images from four patients with pneumonia and one with lung cancer.
Results
The overall DSC for lung tissue was 0.967 ± 0.076 (mean ± standard deviation) and HD was 4.1 ± 4.4 mm. Lung volumes derived from manual and deep learning based segmentations as well as values for fractional ventilation exhibited a high overall correlation (Pearson’s correlation coefficent = 0.99 and 1.00). For the additional cohort with unseen pathologies / consolidations, mean DSC was 0.930 ± 0.083, HD = 12.9 ± 16.2 mm and the mean difference in lung volume was 0.032 ± 0.048 L.
Conclusions
Deep learning-based image segmentation in stack-of-spirals based lung MRI allows for accurate estimation of lung volumes and fractional ventilation values and promises to replace the time-consuming step of manual image segmentation in the future.
Retrospektive Analyse von Doppelkontrastpharyngographie (DkPh) und CT im Vergleich mit indirekter und direkter Laryngoskopie. Dazu wurden die Untersuchungsergebnisse von 151 Pat. mit Tumoren des Pharynx und des supraglottischen Larynx bezüglich Detektion und korrekter Stadienzuordnung nach dem TNM-System unter besonderer Berücksichtigung des subregionalen Befalls ausgewertet. Die DkPh stellt eine sinnvolle Ergänzung zur indirekten Laryngoskopie zur Tumordetektion dar, die Sensitivität wurde durch Kombination im Vergleich zu den einzelnen Verfahren signifikant verbessert. Zum Staging ist sie kein geeignetes Verfahren. Die CT Detektiert Tumoren zuverlässig. Bei der korrekten Stadienzuordnung liefert sie v.a. bzgl. Tiefeninfiltration wertvolle Zusatzinformationen. Fortgeschrittene Tumorstadien werden daher durch die CT signifikant besser dem korrekten T-Stadium zugeordnet als Tumor in frühen Tumorstadien. Durch Kombination von CT und direkter Laryngoskopie wurde die Sensitivität bzgl. einer korrekten Stadienzuornung im Vergleich zu den Einzelverfahren signifikant verbessert.
Seit März 2004 ist im Zentrum für operative Medizin der Universitätsklinik Würzburg der Schockraum mit einem Somatom Sensation 16 der Firma Siemens, einem CT mit Sliding-Gantry in Betrieb. Auch schwer verletzte Kinder werden hier nach dem Würzburger Schockraumalgorithmus behandelt. Insgesamt gibt es nur wenige Daten zur Anwendung von GK-CT bei Kindern. Die DGU beschreibt im TraumaRegister die Daten von zuletzt 266 Kliniken. Nur 5,1 % dieser Daten stammen von Kindern unter 16 Jahren. Die Unterschiede zu Erwachsenen entstehen durch die geringere Erfahrung im Straßenverkehr, die kindliche Anatomie, die größere Gefährdung durch den hypovolämischen Schock und die bessere Rekonvaleszenz von Kindern. Ebenso ist die radiologische Diagnostik durch das geringere Körpervolumen und die höhere Strahlenempfindlichkeit der Kinder problematischer. Der Schockraumalgorithmus der Universitätsklinik Würzburg besteht aus der Reanimations-, CT- und Versorgungsphase. Die Indikation zur GK-CT wird nach dem Triage-Schema gestellt und ist auch bei polytraumatisierten Kindern Diagnostik der Wahl. Die Schwere der Verletzungen wird mit dem ISS bestimmt. In den Jahren 2004 bis 2009 wurden 72 Kinder mit Verdacht auf ein Polytrauma behandelt. Davon erhielten 57 (79,2%) ein GK-CT, 15 (20,1 %) erhielten eine organbezogene CT (CCT, Thorax, Abdomen). 15 (26,3 %) der 57 Kinder mit GK-CT hatten retrospektiv kein Polytrauma (ISS < 16), wobei hier von einer Overtriage auszugehen ist. Die Kinder wurden hauptsächlich im Straßenverkehr und hier als Beifahrer eines PKWs verletzt, gefolgt von den Radfahrern und Fußgängern, die von einem PKW erfasst wurden. Ein Drittel der Patienten erlitt Sturzverletzungen aus bis zu fünf Metern Höhe. Die am häufigsten verletzte Körperregion war mit 52,8 % der Kopf, gefolgt vom Thorax, den Extremitäten und 25 % Gesichtsverletzungen. Dies ist durch die ungünstigere Körper-Kopf-Relation der Kinder erklärbar. Im Vergleich zu Erwachsenen ist bei Kindern vermehrt das Gesicht, der Hals und die untere Extremität verletzt, die Wirbelsäule war weniger betroffen. 82 % der Kinder wurden maschinell beatmet, davon 65% initial und 14% in der ZNA. Es wird empfohlen, Kinder frühzeitig zu intubieren, was sich in der Intubationsrate von 82% widerspiegelt. Eine Notfalloperation wurde in 38,9 % der Fälle durchgeführt, wobei es sich hauptsächlich um Frakturrepositionen handelte, vor allem bei Kindern mit ISS < 16. Bei Kindern mit ISS ≥ 16 wurde in 8,8 % der Fälle eine Kraniotomie durchgeführt. Insgesamt wurden 62 % der Kinder operiert, wobei es sich auch bei den Operationen im Verlauf hauptsächlich um Frakturrepositionen handelte. 15 Kinder erhielten kein GK-CT als primäre Diagnostik, obwohl dies retrospektiv gemäß des Triage-Schemas indiziert gewesen wäre. Bei diesen Kindern wurden zusätzlich zum CCT selektive CTs, Röntgenaufnahmen und Abdomenultraschalluntersuchungen durchgeführt. Bei sechs Kindern wurde trotz initialer GK-CT eine therapierelevante Diagnose erst im Verlauf des Klinikaufenthalts gestellt. Dabei handelte es sich um eine Schädelbasis-, eine Orbitaboden-, eine Klavikula-, eine Talusfraktur, ein Mesenterialarterieneinriss und eine Ileumruptur. Ein Kind verstarb, weil dessen Ileumruptur in der radiologischen Diagnostik nicht detektiert wurde und die Zeit bis zur Laparotomie verzögerte. Während des Krankenhausaufenthalts wurde zur Verlaufsdokumentation die Röntgenuntersuchung, gefolgt von der Sonographie, am häufigsten angewendet. Die CT tritt hierbei in den Hintergrund, wobei die MRT häufiger durchgeführt wurde als bei der initialen Diagnostik.
Die Strahlenbelastung des pädiatrischen Kollektivs ist im Kontext der schnellen Diagnoseerhebung therapierelevanter Verletzungen zu sehen. Bei der GK-CT ist mit einem durchschnittlichen DLP von 2268 mGy•cm, bei der CCT von 956 mGy•cm zu rechnen. Bei den Röntgenuntersuchungen ein DFP von 4 cGy•cm2 bei Thoraxröntgenuntersuchungen und 11 cGy•cm2 bei anderen Röntgenuntersuchungen. Zur korrekten Einordnung der Strahlendosis sind genauere Richtwerte für Kinder und genauere Protokolle nötig. Die GK-CT ist Methode der Wahl bei polytraumatisierten Kindern und wird nur in seltenen Fällen von der FAST oder der Röntgenuntersuchung ersetzt. Trotz der GK-CT können nicht alle therapierelevanten Diagnosen gestellt werden. Insgesamt verbrachten die Kinder durchschnittlich 17 Tage im Krankenhaus und sieben Tage auf der Intensivstation. 77,8 % konnten danach nach Hause entlassen werden, sieben Kinder mussten nach dem Krankenhausaufenthalt in eine Rehabilitationsklinik verlegt werden. Die Letalität der Kinder ist mit 10,5% (n=6) im Vergleich zu den Erwachsenen mit 13,5 % und anderen Studien mit einer pädiatrischen Letalität mit durchschnittlich 18 % geringer. Vier Kinder verstarben an schwerem SHT, ein Kind in Folge seines schweren Thoraxtraumas und ein Kind entwickelte eine Sepsis in Folge einer in der radiologischen Diagnostik nicht detektierbaren Ileumruptur.
Die radiologische Diagnostik des kindlichen Polytraumas hat sich durch das MSCT in den letzten Jahren stark gewandelt. Die geringe Letalität unseres Patientenkollektivs ist ein deutlicher Hinweis auf die Effizienz des Würzburger Schockraumalgorithmus auch beim pädiatrischen Polytrauma.
Die diffusionsgewichtete Magnetresonanztomographie (DW-MRT) ist ein fester Bestandteil der radiologischen Diagnostik des Zentralnervensystems (ZNS), und zwar nicht nur bei Schlaganfällen sondern zunehmend auch bei Hirntumoren, Schädelhirntraumata, demyelinisierenden, degenerativen sowie entzündlichen Erkrankungen. Diese Pathologien gehen in der Regel mit einer Veränderung der lokalen Diffusionsbedingungen einher, die eine reguläre Diffusionsbildgebung beeinträchtigen. Durch die Bestimmung der Diffusionsparameter lassen sich mit Hilfe verschiedener mathematischer Verfahren Faserverbindungen visualisieren. Wie sich diese unterschiedlichen Methoden in Regionen mit aversiven Diffusionsbedingungen verhalten, konnte mit der Arbeit erstmals systematisch gezeigt werden. Hierzu wurden 29 Patientenuntersuchungen ausgewertet. Als Einschlusskriterium galt eine unilaterale, diffusionsrelevante Läsion mit Bezug zur Pyramidenbahn. Ausschlusskriterium war eine vollständige Hemiparese als Zeichen einer vollständigen Zerstörung der relevanten Leitungsbahn. Im Einzelnen handelte es sich bei den untersuchten Läsionen um drei höhergradige Astrozytome (WHO Grad III-IV), drei niedriggradige Astrozytome, acht Glioblastome, zwei Karzinommetastasen, zwei arteriovenöse Malformationen und je eine entzündliche Parasitose, ein Oligodendrogliom, eine Gliomatose und ein Kavernom. Untersucht wurden zwei deterministische (einfaches und interpoliertes streamlining) und drei probabilistische Methoden (ohne crossing fibers; mit Berechnung von zwei Fasern pro Voxel und constrained/bayesian). Läsionen jeglicher Art verursachten signifikant mehr Fehlschläge bei deterministischer als bei probabilistischer Traktographie. In neun Untersuchungen bei einfacher und in acht Untersuchungen bei interpolierter Traktographie zeigten sich fasch negative Ergebnisse. Probabilistisches Traktographieren eliminiert nicht falsch negative Ergebnisse, reduziert sie jedoch unter den oben genannten aversiven Difussivitätsbedingungen mit denen intraaxiale Läsionen einhergehen. Klinisches Wissen über die verbliebene Traktintegrität ermöglicht die Umwandlung der Traktographieergebnisse in Wahrscheinlichkeitswerte innerhalb eines Bayschen Modells. Außerdem ist nur unter Miteinbeziehung klinischer Informationen eine Traktographie nach dem constrained Modell möglich. Obwohl die probabilistische Traktographie weniger anfällig für falsch negative Ergebnisse ist als die deterministische, geht die erhöhte Sensitivität der Algorithmen auf Kosten der Spezifität. Dies zeigt sich in signifikant erhöhten bilateralen Traktvolumina und einem übermäßigen Unterschied der Traktvolumina von Läsionsseite zu kontralateraler Seite. Die probabilistisch, unconstrained durchgeführte Traktographie der Pyramidenbahn zeigte eine signifikant, durch die Läsion verursachte Volumenminderung des Traktes, während dies im constrained modellierten Fall durch die Daten nicht gezeigt werden konnte. Dies zeigt die Robustheit des Constrained Modells unter den aversiven klinischen Bedingungen einer intraaxialen Läsion ohne den Nachteil von erhöhten Fehltraktographien. Es kann konstatiert werden, dass sich die deterministischen Traktographieverfahren zur präoperativen Orientierung vor neurochirurgischen Eingriffen eignen. Jedoch ist eine nicht zu unterschätzende Anzahl von falsch negativen Ergebnissen zu berücksichtigen. In zweifelhaften Fällen sollte zusätzlich eine Darstellung mittels probabilistischen Algorithmen, am besten mittels Constrained Modell durchgeführt werden.
Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Einführung M. Fabry ist eine x-chromosomal vererbte Enzymmangelerkrankung und führt zu progressiver Niereninsuffizienz und hypertropher Kardiomyopathie. Ziel dieser Studie war die Analyse der kardialen Veränderungen im Rahmen der Erkrankung und unter Enzymersatztherapie (ERT) mittels kontrastmittelgestützter Magnetresonanztomographie (MRT). Material und Methoden 25 Patienten (4 Frauen, Alter 18-55 Jahre) mit genetisch bestätigtem M. Fabry wurden vor und nach 12 Monaten ERT mit Fabrazyme® untersucht. Es erfolgte eine umfassende Analyse morphologischer und funktioneller Parameter des linken Ventrikels (LV) mit Fokussierung auf regionale Wandveränderungen sowie Late Enhancement (LE). Eine Gruppe von 43 gesunden Probanden diente als Kontrollgruppe. Ergebnisse Vor Therpiebeginn war bei 50% aller Patienten eine LV Hypertrophie mit erhöhter enddiastolischen Wanddicke (EDWT) nachweisbar. Die ERT führte zu einer Reduktion der EDWT und der LV Masse um 3,6 bis 10,3% innerhalb von 12 Monaten. Die initial erhöhten LV Volumina nahmen ebenfalls unter Therapie ab. Männliche Patienten wiesen eine eingeschränkte Ejektionsfraktion (EF) auf als Zeichen einer globalen Herzinsuffizienz, welche sich unter Therapie signifikant verbesserte. Die segmentale Analyse der systolischen Wanddickenzunahme (WT) zeigte teils ausgedehnte Wandbewegungsstörungen und eine Verbesserung der Kontraktilität unter ERT. Letztere war am stärksten ausgeprägt, wenn kein LE vorhanden war. Ein LE in der LV Seitenwand ist charakteristisch für M. Fabry und konnte bei 11 von 21 männlichen Patienten nachgewiesen werden mit einem Volumen von durchschnittlich 1,9 ± 1,8% der LV Masse. Das Ausmaß nahm häufig unter Therapie noch zu, es kam zu keiner Reduktion. Allerdings wurde auch kein Neuauftreten beobachtet. Frauen waren nicht betroffen. Das Alter LE-positiver Patienten lag etwa 10 Jahre über dem LE-negativer Patienten. Im Frauenkollektiv war die LV Hypertrophie geringer ausgeprägt als bei männlichen Patienten, lag aber dennoch über dem Normwert. Zwar war der Schweregrad der segmentalen Hypertrophie geringer, aber die regionale Verteilung war dennoch ähnlich der bei männlichen Patienten und blieb unter ERT auf hohem Niveau konstant. Auch die regionale Kontraktilität war mäßig beeinträchtigt und durchaus vergleichbar mit dem Ausmaß der Wandbewegungsstörungen bei LE-negativen männlichen Patienten. Bei Frauen war keine globale LV Insuffizienz nachweisbar. Dennoch belegen die erhöhte LV Wanddicke und segmentale Hypokinesien eine messbare kardiale Beeinträchtigung durch M. Fabry auch bei heterozygoten Patienten. Fazit Insgesamt erwies sich die MRT des Herzens als ideales Instrument zur strahlungsfreien Überwachung von Fabry Patienten unter ERT. So können bereits diskrete und regional beschränkte Veränderungen mit hoher Reliabilität diagnostiziert werden, auch in Regionen, die der Echokardiographie nur schwer zugänglich sind. Die LV Masse ist bereits in frühen Krankheitsstadien erhöht und korreliert gut mit der allgemeinen Erkrankungsschwere. Desweiteren impliziert die enge Verknüpfung zwischen Hypertrophie, erhöhten LV Volumina, Wandbewegungsstörungen und letztenendes globaler Herzinsuffizienz, dass die LV Hypertrophie einen wichtigen und früh sichtbaren Risikofaktor darstellt. Das LE als Zeichen der myokardialen Fibrose in späten Erkrankungsstadien ist irreversibel, ebenfalls eng verbunden mit der kardialen Funktion und scheint ein weiterer Risikofaktor zu sein für ein vermindertes Therapieansprechen. Mit dem Auftreten eines LE und zunehmenden LE-Scores erhöht sich die Wahrscheinlichkeit des Auftretens einer LV Hypertrophie und von Wandbewegungsstörungen. Das Patientenalter hatte keinen offensichtlichen Einfluss auf die Wirkung der ERT. Es gibt jedoch Hinweise auf eine Art „point of no return“, jenseits dessen der Therapieeffekt - zumindest das Herz betreffend - begrenzt zu sein scheint.
ZIEL: In den letzten Jahren ist die kontrastverstärkte sonographische Refluxprüfung, d.h. die Miktionsurosonographie (MUS), zunehmend zu einer Alternative gegenüber der standardmäßig eingesetzten Miktions-zysturethrographie (MCU) für die Diagnostik des vesikoureteralen Reflux (VUR) geworden. Eine der Einschränkungen sind jedoch die sehr hohen Kosten des Ultraschallkontrastmittels. Durch Entwicklung von neuen Ultraschallkontrastmitteln erhofft man sich aufgrund vergleichbarer Bildqualität in deutlich niedrigerer Dosis entsprechend eine Reduktion der Kosten zu erreichen. Thema dieser Studie ist eines dieser neuen Ultraschallkontrastmittel (SonoVue®) mit dem in der Routine verwendeten US-Kontrastmittel Levovist® in-vitro unter Betrachtung der für die Refluxdiagnostik relevanten physikalisch-chemischen Eigenschaften zu vergleichen. MATERIAL UND METHODEN: Der in-vitro Versuchsaufbau simulierte die in-vivo durchgeführte MUS. Verwendet wurden die Abbildungsmodalitäten Fundamental und Harmonic Imaging (THI/ECI, Sonoline Elegra®, Siemens), letztere sowohl mit einem niedrigen als auch mit einem hohen Mechanical Index (MI). SonoVue® wurde in einer Konzentration von 0,25%, 0,5% und 1%, Levovist in einer Konzentration von 5% bezogen auf ein Gesamtvolumen in-vitro von 20ml getestet. Als Vergleichsparameter diente die in-vitro Kontrastdauer. Diese wurde definiert als der Zeitraum vom Beginn der Messung bis zu dem Zeitpunkt, an dem auf mehr als 50% der Bildfläche keine echogenen Mikrobläschen mehr nachweisbar waren. ERGEBNISSE: Die Änderung der oben genannten Konzentrationen hatte keinen entscheidenden Einfluss auf die Kontrastdauer von SonoVue®. Darüber hinaus konnte beim Umschalten von THI low MI auf THI high MI die Kontrastdauer von SonoVue® signifikant verlängert werden. Betrachtet man die Abbildungsmodalität THI mit hohem MI, welche routinemäßig bei Levovist® angewendet wird, so zeigte sich, dass die Kontrastdauer bei Levovist® in einer Konzentration von 5% bei 1,1 Minuten lag, bei SonoVue® hingegen erhielten wir bei einer Konzentration von 1% eine Kontrastdauer von 7,3 Minuten. Dies bedeutet, dass trotz Verwendung einer fünffach geringeren Dosis bei SonoVue® sich die Kontrastdauer in-vitro um mehr als 80% verlängerte. Darüber hinaus blieb die Kontrastdauer von SonoVue® über einen Zeitraum von 6 Stunden weitestgehend stabil, während bei Levovist® die Kontrastdauer schon nach 0,5 Stunden eine deutliche Reduktion zeigte. SCHLUSSFOLGERUNG: Es ist zu erwarten, dass SonoVue® auch bei intravesicalen Applikationen in einer deutlich niedrigeren Dosis (1% des Blasenvolumens) verwendet werden kann und dass mehrere Untersuchungen über einen längeren Zeitraum mit einer Flasche SonoVue® durchgeführt werden können. Somit würde eine Kostenreduktion erreicht werden.
Die Riesenzellarteriitis (RZA) ist in der Altersgruppe der über 50-Jährigen die häufigste idiopathische systemische Vaskulitis. Die Erkrankung bedarf einer zeitnahen Diagnostik und Therapie, um schwere Komplikationen wie eine Erblindung oder einen Schlaganfall zu vermeiden. Die Rezidivneigung erfordert eine mehrjährige, zum Teil lebenslange Glukokortikoid(GC)-Therapie, was das Risiko GC-induzierter Langzeitnebenwirkungen erhöht. Daher wird bei der Mehrzahl der Patienten eine additive GC-einsparende Therapie empfohlen. Hierzu steht der Anti-IL-6-Rezeptor-Antikörper Tocilizumab in subkutaner Applikation als zugelassene Substanz zur Verfügung, alternativ kann Methotrexat (MTX) eingesetzt werden (off-label).
Es wurde die diagnostische Genauigkeit fünf verschiedener Rekonstruktionsalgorithmen der DE-CTA der Becken-Bein-Gefäße von Patienten mit pAVK an einem Dual-Source CT mit dem diagnostischen Goldstandard der DSA verglichen. Die DE-CTA zeigte eine exzellente Sensitivität an Becken- und Beingefäßen hinsichtlich einer korrekten Stenosegraduierung, unabhängig von der Rekonstruktion. Die Standard MPR zeigte insgesamt die besten Ergebnisse und ist deshalb vor allem in nicht eindeutigen Fällen die Methode der Wahl. Die Auswertung von DE-CS MPRs, DE-CS MIPs, gekrümmten MPRs oder die semi-automatische quantitative Stenosegradauswertung bringt keinen Zugewinn an diagnostischer Performance im Vergleich zur visuellen Auswertung der Standard MPR. Das Ausmaß der Gefäßwandverkalkungen und die intraluminale Kontrastierung hatten keinen signifikanten Effekt auf die Sensitivität zur Erkennung signifikanter Stenosen an den Becken- und Beingefäßen. Jedoch verschlechterten sich die Spezifität und die Genauigkeit der Rekonstruktionen, welche auf der DE-Knochen- und DE-Plaqueentfernung basieren, signifikant in stark verkalkten oder nur schwach kontrastierten Gefäßsegmenten. Beim Auswerten von DE-CS Rekonstruktionen ist infolgedessen vor allem in schlecht kontrastierten oder stark verkalkten Gefäßen eine weitere Verifizierung des Befundes nötig, um unnötige invasive DSAs als Folge von falsch positiven CTA-Befunden zu reduzieren.
Das Signal-zu-Rausch-Verhältnis (SNR) stellt bei modernen Bildgebungstechniken in der Magnetresonanz-Tomographie heutzutage oftmals die entscheidende Limitation dar. Eine Verbesserung durch Modifikation der Hardware ist kostspielig und führt meistens zu einer Verstärkung anderer Probleme, wie zum Beispiel erhöhte Energiedeposition ins Gewebe. Im Gegensatz dazu ist Dichtegewichtung eine Methode, die eine SNR-Erhöhung durch Modifikation der Aufnahmetechnik ermöglicht. In der MR-Bildgebung erfolgt oftmals eine retrospektive Filterung des aufgenommenen Signalverlaufs, beispielsweise zur Artefaktreduktion. Damit einhergehend findet eine Veränderung der Modulationstransferfunktion (MTF) bzw. ihrer Fouriertransformierten, der räumlichen Antwortfunktion (SRF), statt. Optimales SNR wird nach dem Matched Filter-Theorem erzielt, wenn die nachträgliche Filterung dem aufgenommenen Signalverlauf proportional ist. Dies steht dem Ziel der Artefaktreduktion entgegen. Bei Dichtegewichtung steht durch nicht-kartesische Abtastung des k-Raums mit der k-Raum-Dichte ein zusätzlicher Freiheitsgrad zur Verfügung. Dieser ermöglicht es, im Falle eines konstanten Signalverlaufs eine gewünschte MTF ohne Filterung zu erreichen. Bei veränderlichem Signalverlauf kann ein SNR Matched Filter angewendet werden, dessen negative Einflüsse auf die MTF durch Dichtegewichtung kompensiert werden. Somit ermöglicht Dichtegewichtung eine vorgegebene MTF und gleichzeitig ein optimales SNR. In der vorliegenden Arbeit wurde Dichtegewichtung erstmals bei den schnellen Multi-Echo-Sequenzen Turbo-Spin-Echo und Echoplanar-Bildgebung (EPI) angewendet. Im Gegensatz zu bisherigen Implementierungen muss hier der Signalabfall durch T2- bzw. T2*-Relaxation berücksichtigt werden. Dies führt dazu, dass eine prospektiv berechnete dichtegewichtete Verteilung nur bei einer Relaxationszeit optimal ist. Bei Geweben mit abweichenden Relaxationszeiten können sich wie auch bei den kartesischen Varianten dieser Sequenzen Änderungen an SRF und SNR ergeben. Bei dichtegewichteter Turbo-Spin-Echo-Bildgebung des Gehirns konnte mit den gewählten Sequenzparametern ein SNR-Vorteil von 43 % gegenüber der kartesischen Variante erzielt werden. Die Akquisition wurde dabei auf die T2-Relaxationszeit von weißer Substanz optimiert. Da die meisten Gewebe im Gehirn eine ähnliche Relaxationszeit aufweisen, blieb der visuelle Gesamteindruck identisch zur kartesischen Bildgebung. Der SNR-Gewinn konnte in der dichtegewichteten Implementierung zur Messzeithalbierung genutzt werden. Dichtegewichtete EPI weist eine hohe Anfälligkeit für geometrische Verzerrungen, welche durch Inhomogenitäten des Hauptmagnetfeldes verursacht werden, auf. Die Verzerrungen konnten erfolgreich mit einer Conjugate Phase-Methode korrigiert werden. Dazu muss die räumliche Verteilung der Feldinhomogenitäten bekannt sein. Dazu ist zusätzlich zur eigentlichen EPI-Aufnahme die zeitaufwendige Aufnahme einer sogenannten Fieldmap erforderlich. Im Rahmen dieser Arbeit konnte eine Methode entwickelt werden, welche die zur Erlangung einer Fieldmap notwendige Aufnahmedauer auf wenige Sekunden reduziert. Bei dieser Art der Fieldmap-Aufnahme müssen jedoch durch Atmung hervorgerufene Effekte auf die Bildphase berücksichtigt werden. Die Fieldmap-Genauigkeit kann durch Aufnahme unter Atempause, Mittelung oder retrospektiver Phasenkorrektur erhöht werden. Für die gewählten EPI-Sequenzparameter wurde mit Dichtegewichtung gegenüber der kartesischen Variante ein SNR-Gewinn von 14 % erzielt. Anhand einer funktionellen MRT (fMRI)-Fingertapping-Studie konnte demonstriert werden, dass die SNR-Steigerung auch zu einer signifikant erhöhten Aktivierungsdetektion in Teilen der Hirnareale führt, die bei der Fingerbewegung involviert sind. Die Verwendung von zusätzlicher EPI-Phasenkorrektur und iterativer Optimierung der dichtegewichteten k-Raum-Abtastung führt zu weiteren Verbesserungen der dichtegewichteten Bildgebung mit Multi-Echo-Sequenzen.
Die Arbeit befasst sich mit der Frage, welche Bedeutung die Radiologie in ihrer Anfangszeit (1895-1912) für die Verselbstständigung der Kinderheilkunde zur eigenen klinischen Disziplin hatte. Sie verdeutlicht dies anhand ausgewählter Krankheitsbilder bei denen die Radiologie neue Erkenntnisse erbrachte, eine frühere und beweiskräftigere Diagnose ermöglichte, eine effektivere Therapie zuließ oder auch ein verstärktes Interesse an den medizinischen Besonderheiten des Kindesalters weckte. In diesem Zusammenhang werden auch Ergebnisse der entsprechenden Grundlagenforschung dargestellt, wie zum Beispiel die Ossifikationsstudien. Insgesamt werden, basierend auf konkreten Beispielen, Zusammenhänge zwischen radiologischer Forschung und der Forderung nach Verselbstständigung der Kinderheilkunde als eigenständige Disziplin hergestellt.
Untersuchungen von schwer verletzten Patienten, die in die zentrale Notaufnahme der Universität Würzburg eingeliefert wurden. Es wurde eine relationale Datenbank und entsprechende Auswertemechanismen implementiert, um die Patientendaten zu erfassen, zu strukturieren und auszuwerten. Weiterhin wurde anhand von CT Bildern polytraumatisierter Patienten der ISS berechnet und in die Datenbank eingetragen und entsprechend analysiert. Die Konformität der Verdachtsdiagnose Polytrauma, die anhand bestimmter Kriterien erfolgte, wurde mit dem ISS - Grenzwert 16 verglichen.
Die interventionelle Radiologie hat sich in den letzten Jahrzehnten zunehmend auf palliativmedizinische sowie onkologische Bereiche ausgeweitet und kann durch minimal-invasive Therapieoptionen gerade in vulnerablen Patientenkollektiven attraktive Behandlungsmöglichkeiten zur Verfügung stellen. Die tumorbedingte untere Einflussstauung ist ein seltenes Krankheitsbild und stellt eine schwere symptomatische Komplikation einer malignen Grunderkrankung dar. Dabei kommt es im Rahmen dieser Grunderkrankung durch die Primärtumormasse oder Metastasen zu extrinsischer Kompression der Vena cava inferior (VCI), Gefäßinvasion oder Thrombusbildung.
Ziel der Dissertationsarbeit ist es, den technischen und klinischen Erfolg der Sinus-XL ® Stentimplantation in die Vena cava inferior bei einer tumorbedingten unteren Einflussstauung zu untersuchen. Als technischer Erfolg wurde dabei die problemlose Stentimplantation mit anschließender Aufhebung der VCI-Stenose/Okklusion und Revaskularisation der VCI definiert. Bezüglich des klinischen Erfolges wurde der Frage nachgegangen, inwieweit die Stentimplantation die typischen Symptome einer unteren Einflussstauung (Ödeme der unteren Extremität, Aszites und Anasarka) lindern und bestenfalls eliminieren kann. In der vorliegenden Arbeit sind dazu retrospektiv die Daten von insgesamt 21 Patienten (11 Frauen, 10 Männer) mit einem medianen Alter von 61 Jahren (19-92 Jahre), die zwischen Oktober 2010 und Januar 2021 aufgrund einer tumorbedingten unteren Einflussstauung mit einem Sinus-XL ® Stent endovaskulär versorgt wurden, ausgewertet worden. Zur Quantifizierung der klinischen Symptomatik wurde für das jeweilige Symptom ein Scoring-System entwickelt bzw. modifiziert.
Der technische Erfolg belief sich auf 100% (21/21). Postinterventionell konnte zudem eine signifikante Reduktion des transstenotischen Druckgradienten (p = 0,008) und eine signifikante Aufweitung des Stenosendiameters (p < 0,001) erreicht werden. Die primäre und primär-assistierte Stentoffenheit betrug 92,9 % (13/14) und 100% (14/14), die anatomische Stentoffenheit (< 50% Restenose) belief sich auf 53,3 % (8/15). Die Reinterventionsrate lag bei 4,8 % (1/21). Schwerwiegende Komplikationen traten nicht auf. Der klinische Erfolg bezüglich der Ödeme der unteren Extremität belief sich auf 82,4 % (14/17), 93,8 % (15/16) sowie auf 85,7 % (18/21) und zeigte in allen betrachteten Zeitintervallen eine signifikante Scorewertreduktion (p < 0,001). Das klinische Outcome bezüglich der Ödeme war bei kürzeren Stenosen/Obstruktionen signifikant besser (p = 0,025). Bezüglich einer intrahepatischen Segmentbeteiligung, der transstenotischen Druckgradienten, der absoluten Gradientenreduktion sowie der Überlebenszeit nach der Intervention zeigten sich hingegen keine als klinisch relevant einzustufende Ergebnisse. Ein eindeutiger Effekt der Intervention auf die Symptome Anasarka und Aszites konnte nicht nachgewiesen werden. Diesbezüglich zeigten sich klinische Erfolgsraten von 42,9 % (6/14) und 5,3 % (1/19). Im postinterventionellen Verlauf konnten außerdem signifikante Reduktionen der präinterventionellen Harnstoffwerte sowie des Körpergewichtes der Patienten verzeichnet werden.
Zusammenfassend zeigt die vorliegende Arbeit, dass die Sinus-XL ® Stentimplantation geeignet ist, eine tumorbedingte Vena cava inferior-Stenose/Obstruktion aufzuheben und eine Revaskularisation der VCI zu erreichen. Die klinischen Symptome einer unteren Einflussstauung – insbesondere bezogen auf die Ödeme der unteren Extremität und mit Einschränkungen bezogen auf die Symptome Aszites und Anasarka – können ebenfalls durch die Stentimplantation gelindert und teilweise sogar langanhaltend eliminiert werden. Die Sinus-XL ® Stentimplantation sollte daher stets als Therapieoption bei tumorbedingten unteren Einflussstauungen in Erwägung gezogen werden. Nicht zuletzt stellt die Stentimplantation auch eine sichere und komplikationsarme Intervention dar. Weitere Studien, bestenfalls multizentrische Studien, sind jedoch notwendig, um die dargestellten Ergebnisse weiter zu untermauern.
Zusammenfassung Einleitung: Die Therapie der Lebertumore stellt nach wie vor eine Herausforderung für alle beteiligten Disziplinen dar. Die Universitätskliniken Würzburg verfügen über ein interdisziplinäres Therapiekonzept. Diese Studie aus der Abteilung für Röntgendiagnostik der Universität Würzburg ist ein Vergleich der eigenen Ergebnisse nach interventionellen Therapien von Lebertumoren, im Speziellen nach TACE, mit Daten der Literatur. Besonders berücksichtigt wurden die Auswirkungen auf die Lebensqualität und mögliche Komplikationen. Material und Methode: Von September 1994 bis April 2003 wurden die Lebertumore von 54 Patienten mit insgesamt 135 transarteriellen Chemoembolisationen (TACE) behandelt. Berücksichtigt wurden das Verhalten des Tumors, die Entwicklung des Karnofsky-Index, die Dauer des stationären Aufenthalts, die Kombination mit weiteren Therapieoptionen, die Überlebenszeit für die Monotherapie mit TACE und die Kombinationstherapie aus TACE und PEI / RFA, die Entwicklung ausgewählter Laborparameter, das Auftreten von Nebenwirkungen und Beschwerden nach TACE, die Ausprägung des Postembolisationssyndroms sowie aufgetretene Komplikationen und Embolisatverschleppungen. Ergebnisse: Die TACE hat sich unter Beachtung ihrer Kontraindikationen und der jeweiligen Situation des einzelnen Patienten als sichere und effektive Methode für die palliative Therapie von Lebertumoren erwiesen. Sie führt zu einer Verlängerung der Überlebenszeit, wobei sich die Kombination aus TACE und PEI / RFA der Monotherapie mit TACE überlegen darstellte. Auftretende Nebenwirkungen sind in der Regel vorübergehend, schwere Komplikationen und wesentliche Einschränkungen der Lebensqualität traten nur in Einzelfällen auf. Schlussfolgerung: Die Ergebnisse aus unserer Abteilung weisen eine gute Verträglichkeit der TACE für die Patienten nach und unterstreichen ihren Stellenwert in der Therapie primär inoperabler Lebertumore.
Das Ziel der Studie bestand darin, die Durchführbarkeit, Effizienz und Sicherheit der perkutanen transluminalen Zangenbiopsie bei biliären Strikturen nach „Cross and push“ Technik am Universitätsklinikum Würzburg zu evaluieren.
Die Gewinnung der Zangenbiopsie bei den insgesamt 17 Patienten erfolgte an den baugleichen Angiographieeinheiten der interventionellen radiologischen Abteilung.
Die Schaffung des biliären Zugangsweges wurde per Feinnadelpunktion oder über einen bereits einliegenden Drainagekatheter durchgeführt. Nach Vordirigieren einer armierten Führungsschleuse bis unmittelbar vor die Stenose wurden die Gewebeproben mittels Biopsiezange entnommen. Auf diese Weise sollte ein Abknicken des Instrumentariums durch die fibrotische Beschaffenheit der Striktur vermieden und so die Gewebegewinnung erleichtert werden. Im Anschluss folgten die PTCD-Neuanlage bzw. der Katheterwechsel sowie die histologische Auswertung der Zangenbiopsie. Die Dokumentation umfasste den technischen Erfolg, die Biopsieanzahl sowie -größe, die Untersuchungs- und die Fluoroskopiezeit, das Dosisflächenprodukt, die Repräsentativität der Biopsien und die Komplikationsrate.
Die technische Erfolgsrate lag bei 100 %. Bei zehn Patienten und Patientinnen (58,8 %) wurde in der Zangenbiopsie ein Malignom bestätigt. Bei sieben Betroffenen (41,2 %) ergab die Zangenbiopsie einen benignen Befund, wobei dieser in zwei Fällen (11,8 %) falsch negativ war. Die Kriterien der Repräsentativität wurden bei elf Patienten und Patientinnen (64,7 %) erfüllt. Die mediane Biopsiezahl betrug 4 und die Biopsiegröße war 1 - 2 mm. Bei einer medianen Untersuchungszeit von 24 min bemaß sich die mediane Fluoroskopiezeit auf 7,6 min. Das mediane DAP für alle Interventionen betrug 2.593 μGym2. Zu einer Majorkomplikation kam es bei einer Patientin (5,9 %).
Bei der perkutanen transluminalen Zangenbiopsie nach „Cross and push“ Technik handelt es sich um ein effektives und sicheres Verfahren zur histologischen Beurteilung biliärer Strikturen mit einer moderaten Komplikationsrate. Die Anwendung sollte besonders bei proximalen Strikturen in Betracht gezogen werden, wenn die ERCP oder alternative Verfahren nicht erfolgreich waren und parallel eine Entlastung der Cholestase via PTCD intendiert oder bereits vorhanden ist. Zur weiteren Evaluation der Methode ist zukünftig die Betrachtung eines größeren Patientenkollektives nötig. Um das Verfahren mit Alternativmethoden vergleichen zu können, bedarf es randomisierter kontrollierter Studien.
Das Ziel dieser Arbeit war herauszufinden, ob der iFlow-Algorithmus als zusätzlicher Parameter zu Evaluierung des technischen Erfolgs einer Revaskularisation einer Nierenarterienstenose eingesetzt werden kann. Hierfür haben wir die „mean time to peak“ in Sekunden in den farbcodierten Bildern gemessen, um den Effekt einer Stentimplantation auf den Blutfluss zu eruieren. Im Verlauf haben wir dann getestet, ob unsere Ergebnisse den klinischen Verlauf unserer Patienten wiederspiegeln, um feststellen zu können, ob die syngo iFlow-Software den Erfolg der endovaskulären Therapie voraussagen kann.
In vielen Veröffentlichungen ist die Atrophie und die fettige Infiltration der Rotatorenmanschette als wichtiger Prädiktor für den Outcome nach Rekonstruktionen der Rotatorenmanschette belegt worden, insofern, als dass eine fettige Infiltration eine erhöhte Re-Rupturrate bedingt. Der intramuskuläre Fettgehalt wurde bisher mittels einer subjektiven, semiquantitativen Methode, die sich an einer morphologischen CT-Klassifikation orientierte, bestimmt. Durch die in der vorliegenden Arbeit verwendete nichtinvasive 2D-SPLASH Methode ist es möglich, den Verfettungsgrad der Rotatorenmanschettenmuskulatur in einer beliebigen ROI (Region Of Interest) im Rahmen einer Atrophie quantitativ zu bestimmen. Dazu wurden insgesamt 20 Patienten (weiblich/männlich: 7/13, Durchschnittsalter 57,5 ), die unter einem subakromialen Schmerzsyndrom litten, vor der operativen Rekonstruktion der Rotatorenmanschette einer MR-Untersuchung (1,5 T MR Tomograph, Siemens Vision Pro, Siemens AG Erlangen) unterzogen. Die hohe Validität dieser Messmethode ist durch die hochsignifikante Korrelation mit den Phantomuntersuchungen belegt worden. Als weiteres konnte gezeigt werden, dass die fettige Infiltration (bestimmt durch die 2D-SPLASH Methode) nur mäßig mit der mit Hilfe der Quer- und Längsschnittmessungen (cross-sectional areas) bestimmten Muskelatrophie des M. supraspinatus korreliert. Es konnte jedoch ein statistisch gesicherter Zusammenhang zwischen der intramuskulären Verfettung und dem Rupturausmaß belegt werden Zusammenfassend scheint die Entwicklung von Atrophie und fettiger Infiltration der an der Rotatorenmanschette beteiligten Muskeln ein multifaktorielles Geschehen zu sein, an dem eine muskelspezifische Komponente, die Anamnesedauer, die Defektgröße sowie eine Inaktivitäts- und neuromuskuläre Komponente beteiligt sind. Die 31P-MR-Spektroskopie stellt die einzige nichtinvasive Methode dar, mit der der Energiestoffwechsel der Muskulatur in-vivo beurteilt werden kann. In der vorliegenden Arbeit konnten mit Hilfe der 31P-MR-Spektroskopie die Verhältnisse der energiereichen Phosphate, vor allem das Verhältnis zwischen PCr zu ATP, bestimmt werden. Ein signifikanter Unterschied zu einem gesunden Vergleichskollektiv konnte nicht belegt werden. Dabei bleibt fraglich, ob es überhaupt zu einer Veränderung des Energie-stoffwechsels der Rotatorenmanschettenmuskulatur im Rahmen einer Atrophie kommt, wie es bei mitochondrialen, kongenitalen, inflammatorischen und neuropathischen Myopathien nachgewiesen wurde. November 2004
Obwohl der klinische Stellenwert der MRT in zahlreichen Studien für verschiedene Entitäten (AC-Komplex, coracoidale Pathologien, Rotatorenmanschette, Pathologien des Kapsel-Band-Apparates und der Bicepssehne sowie primär und reaktiv bedingte entzündliche Veränderungen) belegt ist, überrascht es, dass in der Literatur keine Arbeiten darüber existieren, inwieweit das Ergebnis der MRT-Untersuchung tatsächlich das therapeutische Procedere beeinflusst. Vorliegende Arbeit untersuchte daher den diagnostischen Impact der MRT im Setting einer hochspezialisierten Schultersprechstunde.
Rotatorenmanschettenrupturen stellen ein häufig auftretendes Krankheitsbild in der Bevölkerungsgruppe der „Über-40-Jährigen“ dar. Die führenden Methoden in der Diagnostik der Rotatorenmanschette sind neben der klinischen Untersuchung die Kernspintomographie und die Sonographie. Die Aussagekraft beider Methoden wurde im Rahmen von Untersuchungen an präoperativen und postoperativen Patienten verglichen. Die Ergebnisse zeigten eine ausgezeichnete Sensitivität (92,9%) und Spezifität (84,2%) der Sonographie in der Erkennung von Rupturen der Rotatorenmanschette, jedoch eine Abnahme der Sensitivität (71,4%) bei Differenzierung der Läsionen in partielle und komplette Rupturen. Bei der Beurteilung der postoperativen Rotatorenmanschette blieben kleine Läsionen aufgrund der Inhomogenität des Echomusters unerkannt, größere Rerupturen wurden in allen Fällen diagnostiziert. Die Treffsicherheit der Kernspintomographie ergab eine Sensitivität von 78.6% (64,3% bei Differenzierung, s.o.), eine Spezifität von 89,5%, wobei die Untersuchungen an einem Niederfeldgerät (0,2 Tesla) mit im Vergleich zu den in der Schulterdiagnostik standardmäßig eingesetzten Kernspintomographen geringerer Auflösung und verminderter Bildqualität durchgeführt wurden. Innerhalb des ersten postoperativen Jahres erschweren Artefakte die Diagnostik der rekonstruierten Rotatorenmanschette, danach erweist sich die Kernspintomographie als ein überaus spezifisches Verfahren, mit welchem auch kleine Läsionen dargestellt werden. Des Weiteren untersucht vorliegende Arbeit anhand von Patienten- und Probandenkollektiven mit rupturierten und intakten Rotatorenmanschetten, inwieweit sich bei unterschiedlichen Ausmaßen von Rotatorenmanschettenrupturen während einer passiven oder aktiven Abduktion des Armes eine Änderung der Biomechanik feststellen läßt. Bei Untersuchungen an einem offenen Kernspintomographen wurden erstmals Verhältnisse geschaffen, welche die aktive und passive Abduktion des Armes ohne und mit Belastung möglichst realitätsnah simulierten. Die Ergebnisse der dynamischen Untersuchung zeigen, daß Rupturen des M.supraspinatus alleine zu keiner signifikanten Veränderung des Bewegungsablaufs führen. Eine zusätzliche Beteiligung des M.infraspinatus dagegen verursachte sowohl im prä- als auch im postoperativen Kollektiv eine signifikante Verringerung des Subakromialraumes, bei zusätzlicher Belastung in den jeweiligen Abduktionsstellungen zeigte sich keine weitere signifikante Translation. Dies verdeutlicht die Rolle des M.infraspinatus, dessen Funktionsdefizit ein permanentes Höhertreten des Humeruskopfes zur Folge hat. Anhand vorliegender Ergebnisse besteht kein Hinweis auf die Bestätigung der These, biomechanische Veränderungen würden zeitlich vor morphologischen Sehnenläsionen auftreten. Sowohl in der präoperativen Diagnostik als auch in der Beurteilung postoperativer Rotatorenmanschetten besitzt die Kernspintomographie einen herausragenden Stellenwert. Durch die dynamische Untersuchung konnte die oft vernachlässigte Bedeutung des M.infraspinatus hervorgehoben werden, dessen Rekonstruktion bzw. Stärkung anzustreben ist, bevor es zu einer weiteren Störung der Biomechanik kommt. Die dynamische Kernspintomographie stellt somit eine wertvolle Methode zur Untersuchung physiologischer und pathologischer Bewegungsabläufe der Schulter dar.
Der Atypische teratoid/rhabdoide Tumor (ATRT) und der primitive neuroektodermale Tumor (PNET) sind hochmaligne Tumorentitäten (WHO-Grad IV) des zentralen Nervensystems, die überwiegend im Kleinkindalter auftreten. Beide zeigen eine sehr heterogene morphologische Struktur und sind bisher nur mittels Histopathologie und Immunhistochemie voneinander zu differenzieren. Bisherige Untersuchungen ließen noch keine neuroradiologische Unterscheidbarkeit zwischen beiden Tumorentitäten erkennen. Die vorliegende Arbeit befasst sich anhand eines diesbezüglich einmalig großen Patientenkollektives (23 ATRT, 36 PNET) mit den spezifisichen morphologischen Kriterien des supratentoriellen (st) ATRT und PNET in der Magnetresonanztomographie (MRT). Die Patienten rekrutierten sich aus der multizentrischen Hirntumorstudie HIT 2000 (Teil des Kompetenznetzes der Hirntumorstudien der „Gesellschaft für pädiatrische Onkologie und Hämatologie“). Retrospektiv wurden MRT-Bilder aus einem Zeitraum von 5 Jahren ausgewertet. Untersucht wurden T1- und T2-Wichtung, nativ und unter Kontrastmittelapplikation. Zur Abgrenzung beider Entitäten voneinander wurden verschiedene Kriterien herausgearbeitet. Dazu zählten zunächst die Darstellung in der nativen T1-Wichtung, die Schärfe der Tumorbegrenzung, das zeitgleiche Vorliegen von Zysten, Ödemen und Blutungen sowie die Ausprägung des Kontrastmittel-Enhancements. Als zentrales Ergebnis der Arbeit konnte ein markantes strukturelles Muster des Kontrastmittel-Enhancements herausgearbeitet werden, welches sich als charakteristisch für den stATRT erwies, während es nur bei einem sehr geringen Prozentsatz der stPNETs anzutreffen war. Hierbei handelt es sich um ein girlandenförmiges Band, welches den Tumor randständig um eine zentrale Nekrose herum auskleidet. Dieses als „ATRT-typisch“ bezeichnete Muster wiesen zehn der stATRTs (43,5%) und drei der stPNETs (8,3%) auf. Darüber hinaus konnte man bei fünf stATRTs (21,7%) Areale mit wie in der Girlande anzutreffenden vesikulären Strukturen aber ohne begleitende zentrale Tumornekrose beobachten. Nur ein stPNET (2,8%) wies ebenfalls vesikuläre Anteile ohne zentrale Nekrose auf. Es konnten somit charakteristische Muster identifiziert werden, welche auffällig häufig in Kontrastmittel-verstärkten T1-gewichteten MRT-Bildern des stATRT in Erscheinung treten, während sie bei stPNETs nur ausgesprochen selten vorzufinden sind.
Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies.
Durch Weiterentwicklungen der MR-Technologie hat die diffusionsgewichtete MRT in der Bildgebung des Abdomens zunehmend an Bedeutung gewonnen. Einige wenige Studien zeigten bereits vielversprechende Ergebnisse für den Einsatz der DWI in der Diagnostik und Verlaufsbeurteilung des Morbus Crohn.
Ziel dieser Arbeit war es, zu untersuchen, ob die DWI zur Detektion entzündlicher Darmwandläsionen und extraluminaler Komplikationen bei pädiatrischen Patienten mit Morbus Crohn ebenso geeignet ist wie die kontrastmittelverstärkte MRT.
Hierzu wurden retrospektiv die klinischen und MR-tomographischen Daten von 48 Kindern, Jugendlichen und jungen Erwachsenen mit Morbus Crohn sowie von 42 Kontrollpatienten ausgewertet, bei denen im Zeitraum zwischen Juli 2008 und Mai 2013 eine MRT-Untersuchung durchgeführt wurde. Aktuelle Befunde einer Ileokoloskopie waren als Referenz bei 60% der Morbus Crohn Patienten und bei etwa einem Drittel der Patienten der Kontrollgruppe vorhanden.
Das Bestehen eines Morbus Crohn konnte bei 47 der insgesamt 48 Patienten anhand der diffusionsgewichteten Sequenzen und in 46 Fällen mittels der kontrastverstärkten T1w-Aufnahmen korrekt nachgewiesen werden. Extramurale Komplikationen wie Abszesse oder Fisteln konnten sowohl mittels DWI als auch durch die KM-MRT detektiert werden. Da die DWI weder eine intravenöse Kontrastmittelapplikation noch Atemanhaltetechniken erfordert, ist sie gerade bei pädiatrischen Patienten ein geeignetes Bildgebungsverfahren. Wegen der relativ geringen Ortsauflösung der diffusionsgewichteten Sequenzen sollte jedoch zusätzlich eine Standardsequenz, wie die T2-gewichtete HASTE-Sequenz, akquiriert werden.
Nach den Ergebnissen dieser Studie ist die diffusionsgewichtete MRT zur Beurteilung der entzündlichen Veränderungen des Morbus Crohn sehr gut geeignet und besitzt das Potenzial, nicht nur ergänzend, sondern als Alternative zur KM-MRT zum Einsatz zu kommen.
Diffusionsgewichtete MRT Bildgebung bei Erkrankungen im Zahn-Mund-Kiefer/Hals-Nasen-Ohren Bereich
(2012)
Zielsetzung: Die Zielsetzung dieser Arbeit war es zu beurteilen, inwieweit die Diffusionsgewichtete MRT Bildgebung bei der Differenzierung zwischen malignen und benignen Erkrankungen im Kopf-Hals Bereich nützlich sein kann. Außerdem ging es um die Sammlung der mittleren ADC-Werte von verschiedenen Diagnosen. Material und Methoden: Es wurden diffusionsgewichtete Bilder mit einer SE-EPI-Sequenz (b-Wert Paarung von 50 und 800 s/mm2, 1,5T) verglichen. 53 Plattenepithelcarzinome (PeCa), 21 benigne Befunde, 6 Lymphome, 6 Hämangiome, 6 Zysten Ergebnis: Die mittlere ADC- Wert (MW x10-3mm²/s +/-SD) der PeCa betrug 0.967 (0.118), der benignen Läsionen 1.458 (0.371), der Lymphome 0.649 (0.167), der Hämangiome 1.654 (0.254), der Zysten 2.310 (0.655) Der mittlere ADC-Wert der PeCa war signifikant kleiner als der der benignen Läsionen. Ein ADC- Wert von 1.202x10-3mm²/s kann als Grenzwert für die Differenzierung zwischen benignen und malignen Läsionen im Kopf-Hals Bereich angesehen werden. Schlussfolgerung: Die ADC-Werte können für die Charakterisierung von Läsionen im Kopf-Hals Bereich genutzt werden.
Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current–time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FD\(_{Ur77}\) and LD\(_{Ur77}\) examinations (p < 0.001) with LD\(_{Ur77}\) scans also providing favorable bone visualization compared to FD\(_{Br69}\) and FD\(_{Br62}\) (p < 0.001). Fleiss’ kappa was 0.618 (0.594–0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.
Background
Demographic change entails an increasing incidence of fragility fractures. Dual-energy CT (DECT) with virtual non-calcium (VNCa) reconstructions has been introduced as a promising diagnostic method for evaluating bone microarchitecture and marrow simultaneously. This study aims to define the most accurate cut-off value in Hounsfield units (HU) for discriminating the presence and absence of bone marrow edema (BME) in sacral fragility fractures.
Methods
Forty-six patients (40 women, 6 men; 79.7 ± 9.2 years) with suspected fragility fractures of the sacrum underwent both DECT (90 kVp / 150 kVp with tin prefiltration) and MRI. Nine regions-of-interest were placed in each sacrum on DECT-VNCa images. The resulting 414 HU measurements were stratified into “edema” (n = 80) and “no edema” groups (n = 334) based on reference BME detection in T2-weighted MRI sequences. Area under the receiver operating characteristic curve was calculated to determine the desired cut-off value and an associated conspicuity range for edema detection.
Results
The mean density within the “edema” group of measurements (+ 3.1 ± 8.3 HU) was substantially higher compared to the “no edema” group (-51.7 ± 21.8 HU; p < 0.010). Analysis in DECT-VNCa images suggested a cut-off value of -12.9 HU that enabled sensitivity and specificity of 100% for BME detection compared to MRI. A range of HU values between -14.0 and + 20.0 is considered indicative of BME in the sacrum.
Conclusions
Quantitative analysis of DECT-VNCa with a cut-off of -12.9 HU allows for excellent diagnostic accuracy in the assessment of sacral fragility fractures with associated BME. A diagnostic “one-stop-shop” approach without additional MRI is feasible.
Purpose
The trauma centre of the Wuerzburg University Hospital has integrated a pioneering dual-room twin-CT scanner in a multiple trauma pathway. For concurrent treatment of two trauma patients, two carbon CT examination and intervention tables are positioned head to head with one sliding CT-Gantry in the middle. The focus of this study is the process of trauma care with the time to CT (tCT) and the time to operation (tOR) as quality indicator.
Methods
All patients with suspected multiple trauma, who required emergency surgery and who were initially diagnosed by the CT trauma protocol between 05/2018 and 12/2018 were included. Data relating to time spans (tCT and tOR), severity of injury and outcome was obtained.
Results
110 of the 589 screened trauma patients had surgery immediately after finishing primary assessment in the ER. The ISS was 17 (9–34) (median and interquartile range, IQR). tCT was 15 (11–19) minutes (median and IQR) and tOR was 96.5 (75–119) minutes (median and IQR). In the first 30 days, seven patients died (6.4%) including two within the first 24 h (2%). There were two ICU days (1–6) (median and IQR) and one (0–1) (median and IQR) ventilator day.
Conclusion
The twin-CT technology is a fascinating tool to organize high-quality trauma care for two multiple trauma patients simultaneously
Ziel: Versuch der Definition von Lebertumoren mit quantitativem dynamischem kontrast-verstärktem Ultraschall anhand der Beurteilung der Vaskularisation, wash-in, wash-out über einen definierten Zeitraum. Korrelation mit histologischen Befunden. Patienten und Methode: 42 Leberläsionen in 39 Patienten wurden mittels „Contrast Harmonic Imaging“ (CHI) über einen Zeitraum von 2 min nach einer Bolusinjektion von 10 ml Levovist® (300mg/ml, Schering AG, Berlin) untersucht. Die Untersuchungen wurden an einem Sonoline Elegra® (Siemens AG, Erlangen) mit einem frequenzvariablen 3,5 MHz Schallkopf durchgeführt. Das Kontrastmittelverhalten der Leberläsionen wurde durch eine speziell für Ultraschallkontrastmittel entwickelte Software (Axius™ ACQ (Siemens, Issaquah, WA)) quantifiziert. Repräsentative ROI wurden in das Zentrum der Läsion, über die gesamte Läsion, in normales Leberparenchym, sowie in repräsentative Lebergefäße (Leberarterie, Lebervene, Portalvene) gelegt. Die Kontrastmittelaufnahme der Leberläsionen wurde unterteilt in arteriell, portal-venös oder venös. Des Weiteren erfolgte eine Unterteilung in hypovaskular, isovaskular und hypervaskular im Vergleich zum normalen Leberparenchym. Zusätzlich wurde das Kontrastmittelverhalten innerhalb der Läsion beurteilt und unterteilt in zentrifugal, zentripetal, peripher und komplett. Alle Leberläsionen wurden vor und nach Kontrastmittelgabe von vier im Ultraschall, CT und MRT erfahrenen Radiologen ausgewertet ohne Kenntnis der Patientendaten oder des histologischen Ergebnis. Das Diagnosekriterium maligne wurde mittels einer ROC-Analyse ausgewertet. Zusätzlich wurden die durchschnittliche Sensitivität, Spezifität, sowie der positive und negative Vorhersagewert berechnet. Ergebnisse: Von 36 Raumforderungen lagen histologische Befunde vor. Histologisch ergaben sich 29 maligne Läsionen (HCC, n=11; CCC n=1; Lymphom, n=1, Metastasen, n=16) und 7 benigne Läsionen (Hämangiom, n=1; FNH, n=4, Adenom n=2). 4 FNH´s und 1 Hämangiom waren durch NUK, MRT und durch Langzeitkontrollen bestätigt. Die Auswertung der ROC-Analyse in Bezug auf das Kriterium maligne schwankte vor Kontrastmittelgabe zwischen 0,43 und 0,62 (Durchschnitt 0,57) und nach Kontrastmittelgabe zwischen 0,7 und 0,8 (Durchschnitt 0,75). Die durchschnittlichen Werte für die Sensitivität, Spezifität, negativer und positiver Vorhersagewert betrugen vor Kontrastmittelgabe 66%, 26%, 45% und 73% nach Kontrastmittelgabe 83%, 49%, 65% und 82%. Diskussion: Die Quantifizierung der verstärkten Gefäßdarstellung in Lebertumoren nach Bolus-Applikation eines Ultraschallkontrastmittels verbessert die Zuordnung zu einem malignen Prozess im Vergleich zum nativen Ultraschall. Um zuverlässigere Diagnosen stellen zu können ist eine Verbesserung der Auswertesoftware sowie die Berücksichtigung der neuen Generation von Ultraschallkontrastmitteln notwendig.
Background
The effect of smoking on coronary vasomotion has been investigated in the past with various imaging techniques in both short- and long-term smokers. Additionally, coronary vasomotion has been shown to be normalized in long-term smokers by L-Arginine acting as a substrate for NO synthase, revealing the coronary endothelium as the major site of abnormal vasomotor response. Aim of the prospective cohort study was to investigate coronary vasomotion of young healthy short-term smokers via magnetic resonance cold pressor test with and without the administration of L-Arginine and compare obtained results with the ones from nonsmokers.
Methods
Myocardial blood flow (MBF) was quantified with first-pass perfusion MRI on a 1.5 T scanner in healthy short-term smokers (N = 10, age: 25.0 ± 2.8 years, 5.0 ± 2.9 pack years) and nonsmokers (N = 10, age: 34.3 ± 13.6) both at rest and during cold pressor test (CPT). Smokers underwent an additional examination after administration of L-Arginine within a median of 7 days of the naïve examination.
Results
MBF at rest turned out to be 0.77 ± 0.30 (smokers with no L-Arginine; mean ± standard deviation), 0.66 ± 0.21 (smokers L-Arginine) and 0.84 ± 0.08 (nonsmokers). Values under CPT were 1.21 ± 0.42 (smokers no L-Arginine), 1.09 ± 0.35 (smokers L-Arginine) and 1.63 ± 0.33 (nonsmokers). In all groups, MBF was significantly increased under CPT compared to the corresponding rest examination (p < 0.05 in all cases). Additionally, MBF under CPT was significantly different between the smokers and the nonsmokers (p = 0.002). MBF at rest was significantly different between the smokers when L-Arginine was given and the nonsmokers (p = 0.035).
Conclusion
Short-term smokers showed a reduced response to cold both with and without the administration of L-Arginine. However, absolute MBF values under CPT were lower compared to nonsmokers independently of L-Arginine administration.
Background
To investigate the effects of B\(_1\)-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI).
Methods
Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field.
Results
B\(_1\)-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B\(_1\)-shimming showed shading artifacts due to local B\(_1\)\(^+\)-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B\(_1\)-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B\(_1\)-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study.
Conclusions
B\(_1\)-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.
Bone marrow lesions (BML) represent areas of deteriorated bone structure and metabolism characterized by pronounced water‐equivalent signaling within the trabecular bone on magnetic resonance imaging (MRI). BML are associated with repair mechanisms subsequent to various clinical conditions associated with inflammatory and non‐inflammatory injury to the bone. There is no approved treatment for this condition. Bisphosphonates are known to improve bone stability in osteoporosis and other bone disorders and have been used off‐label to treat BML. A randomized, triple‐blind, placebo‐controlled phase III trial was conducted to assess efficacy and safety of single‐dose zoledronic acid (ZOL) 5 mg iv with vitamin D 1000 IU/d as opposed to placebo with vitamin D 1000 IU/d in 48 patients (randomized 2:1) with BML. Primary efficacy endpoint was reduction of edema volume 6 weeks after treatment as assessed by MRI. After treatment, mean BML volume decreased by 64.53% (±41.92%) in patients receiving zoledronic acid and increased by 14.43% (±150.46%) in the placebo group (p = 0.007). A decrease in BML volume was observed in 76.5% of patients receiving ZOL and in 50% of the patients receiving placebo. Pain level (visual analogue scale [VAS]) and all categories of the pain disability index (PDI) improved with ZOL versus placebo after 6 weeks but reconciled after 6 additional weeks of follow‐up. Six serious adverse events occurred in 5 patients, none of which were classified as related to the study drug. No cases of osteonecrosis or fractures occurred. Therefore, single‐dose zoledronic acid 5 mg iv together with vitamin D may enhance resolution of bone marrow lesions over 6 weeks along with reduction of pain compared with vitamin D supplementation only.
Eisenpartikelverstärkte Magnetresonanztomographie bei der Experimentellen-Autoimmun-Neuritis(EAN)
(2006)
In diesem experimentellen Ansatz ist es gelungen, durch Einsatz von eisenhaltigen Kontrastmittel die MRT-Spezifität bei peripheren autoimmunen Nervenentzündungen deutlich zu erhöhen. Es ist gelungen in vivo den zeitlichen Verlauf der Monozyten/Makropahgeninfiltration bei entzündliche Autoimmunerkrankungen des Peripheren Nervensystems zu demonstrieren.
In unserer Studie kamen die neuen Verfahren qualitative und semiquantitative Elastographie zum Einsatz. Es sollte gezeigt werden, ob sie als Ergänzung zu den herkömmlichen sonographischen Verfahren die Diagnosestellung von Erkrankungen am Hals bei Kindern und Jugendlichen verbessern können.
Bei der Untersuchung mittels semiquantitativer Elastographie konnten wir in unserer Studie beim Vergleich Schilddrüsen-Normalbefund und Hashimoto-Thyreoiditis einen signifikanten Unterschied der Scherwellengeschwindigkeiten nachweisen. Es zeigte sich, dass Patienten mit Hashimoto-Thyreoiditis signifikant höhere Scherwellengeschwindigkeiten aufweisen als Patienten mit Normalbefund. Für die anderen untersuchten Schilddrüsenerkrankungen, Struma diffusa und Struma nodosa und für die Erkrankungen der Lymphknoten, benigne Veränderung/Entzündung, maligne Veränderung und Abszess, ließ sich kein signifikanter Unterschied feststellen.
Die Sensitivität und Spezifität konnte durch Einsatz des neuen Verfahrens der qualitativen Elastographie nicht gesteigert werden. Während sich bei der Schilddrüsendiagnostik geringere Werte für Sensitivität und Spezifität im Vergleich zu den herkömmlichen Verfahren zeigten, unterschieden sich die Werte bei der Lymphknotenuntersuchung Reader-abhängig.
Bei der Schilddrüsenuntersuchung lag die Bildqualität der konventionellen Sonographie über der der qualitativen Elastographie. Dagegen wurde bei der Lymphknotenuntersuchung die Bildqualität der Elastographiebilder höher bewertet als jene der herkömmlichen Verfahren.
Insgesamt konnte in unserer Studie gezeigt werden, dass Patienten mit Hashimoto-Thyreoiditits signifikant höhere Scherwellengeschwindigkeiten im Schilddrüsengewebe aufweisen, als bei Normalbefund. In der Diagnostik von Schilddrüsen- und Lymphknotenerkrankungen konnte bezüglich des neuen Verfahrens der qualitativen Elastographie eine Überlegenheit gegenüber der konventionellen Sonographie nicht nachgewiesen werden.
Um die Ergebnisse unserer Studie abschließend bewerten zu können, wäre eine Validierung anhand einer größeren Patientengruppe nötig.
In den letzten Jahren wird verbreitet das Coiling, die endovaskuläre Technik zur Behandlung von intrakraniellen Aneurysmata genutzt. Hierbei werden mittels eines Mikrokatheters Platinspiralen unter Durchleuchtung in das Aneurysma platziert. Aufgrund dieser minimal invasiven Methode und positiver Ergebnisse in verschiedenen Studien ist es heute eine Alternative zum bisherigen chirurgischen Clipping, das immer mehr in den Hintergrund gedrängt wurde. In der vorliegenden Studie wird die Rate der periinterventionellen Komplikationen (wie Coildislokationen und Gefäßverschlüsse), der Zusammenhang zwischen der Rekanalisation und der Aneurysmagröße, der Packungsdichte, der verwendeten Spiralen, sowie der Lokalisation des Aneurysmas untersucht. Ziel ist es das Verhältnis der Okklusion des Aneurysmas zu den oben genannten Faktoren zu klären. Im retrospektiven Teil der Studie werden Aneurysmen von 198 Patienten und im prospektiven Anteil 100 Patienten mit 101 Aneurysmen eingeschlossen. Im Anschluss werden die Ergebnisse mit ähnlichen oder vergleichbaren Daten der Literatur, wie z. B. die ISAT und deren Folgestudien, diskutiert. Ein direkter Vergleich war nicht möglich, da diese Studien weitaus größere Patientenanzahlen beinhalteten.
In der Nachsorge des Medulloblastoms wird standardmäßig auf die Bildgebung mittels Magnetresonanztomographie zurück gegriffen. Da die Erkrankung vor allem entlang der Liquorwege in Form einer kranialen oder spinalen Meningeose metastasiert, wurde anhand Daten der Therapieoptimierungsstudie "HIT 2000" verglichen, welche Lokalisation am häufigsten betroffen ist. Es zeigte sich, dass zu einem hohen Prozentanteil vor allem eine kombinierte Meningeose im Rezidiv oder Progress auftritt, gefolgt von einer kranialen Metastasierung. Dennoch gibt es eine Gruppe an Patienten, die eine isolierte spinale Meningeose entwickeln.
Mit dem hier vorgestellten Untersuchungs- und Auswertealgorithmus konnte die Myokardperfusion weitgehend automatisiert semiquantitativ und quantitativ bestimmt werden. Dafür wurden zunächst die Bilddaten segmentiert und in Signalintensitäts-Zeit-Kurven transferiert. Durch eine Basislinien- und Kontaminationskorrektur wurden Artefakte minimiert. Mit Anwendung des Parallel-Bildgebungs-Verfahrens Auto-SENSE konnte zusätzlich eine Erhöhung der Schichtanzahl erreicht werden. Durch die angewendete Basislinienkorrektur konnten Inhomogenitäten verringert werden, welche durch Verwendung einer Oberflächenspule methodenbedingt auftreten. Partialvolumeneffekte, die durch die Morphologie des Herzens insbesondere basis- und spitzennah auftraten, führten durch eine Mischung aus KM-Anflutung im Myokard und Kontamination aus dem Ventrikellumen zu einer Beeinflussung der Perfusionsergebnisse. Durch die Verwendung der vorgestellten Kontaminationskorrektur konnten diese Artefakte erheblich minimiert werden. Die so errechneten Perfusionswerte korrelierten gut mit den in der Literatur angegebenen Daten, welche sowohl in tierexperimentellen als auch Probanden- und auch Patientenstudien mit unterschiedlichen Modalitäten ermittelt wurden. Eine regionale Heterogenität konnte nicht signifikant nachgewiesen werden. Molekular-physiologische Untersuchungen legen zwar nahe, dass es diese Heterogenität gibt, die regionale Verteilung der Perfusion wird jedoch kontrovers und noch keinesfalls abschließend in der Literatur diskutiert. Durch Anwendung von Auto-SENSE konnte mit einer Erhöhung der Schichtanzahl bei gleichbleibender Schichtdicke das gesamte linksventrikuläre Myokard untersucht werden. Trotz verringertem SNR waren die Ergebnisse vergleichbar mit der konventionellen Turbo-FLASH-Technik. Ob das Potential der Parallelbildgebung für eine Abdeckung des gesamten Herzens oder für eine höhere Auflösung von 3-4 Schichten pro Untersuchungen genutzt werden soll, ist in der aktuellen Literatur noch Gegenstand der Diskussion. Die hochaufgelösten Untersuchungen scheinen jedoch derzeit vorteilhafter aufgrund geringerer Partialvolumeneffekte sowie der besseren Beurteilbarkeit einer subendokardialen Zone und eines transmuralen Perfusionsgradienten. Die MR-Perfusionsbildgebung ist ein aktives und rasch wachsendes Gebiet innerhalb der kardialen Bildgebung mit großem Entwicklungspotential. Durch Einbindung in ein umfassendes Herz-MR-Untersuchungsprotokoll (z.B. Morphologie, Kinetik, evtl. MR-Koronarangiographie) ist in einem Untersuchungsgang eine umfassende Diagnostik bei Patienten mit Verdacht auf KHK möglich.
Ziel dieser Arbeit war es, verschiedene Parameter der linksventrikulären Wandbewegung aus MR-tagging-Aufnahmen quantitativ zu analysieren. Die Auswertemethode sollte angewendet werden, um den physiologischen Kontraktionsablauf zu charakterisieren und pathophysiologische Veränderungen zu erfassen. Die tagging-Untersuchung wurde in einer basisnahen, mittventrikulären und einer apikalen Schicht des linken Ventrikels durchgeführt. Für die automatische Quantifizierung von Rotation, Kontraktion und Umfangsverkürzung wurde eine geeignete Software erstellt. Die Methode wurde bei 8 gesunden Probanden, 13 Patienten mit Aortenstenose vor und 1 Jahr nach Klappenersatz und 10 Patienten mit Myokardinfarkt vor und nach Revaskularisation angewendet. Die entwickelte Software gestattet die Quantifizierung der linksventrikulären Wandfunktion über die Bestimmung von Rotation, Kontraktion und Umfangsverkürzung. Bei den Probanden zeigte sich eine Wringbewegung mit gegenläufiger Rotation der Herzbasis zur Herzspitze. Vor Klappenersatz zeigten die Patienten mit Aortenstenose eine signifikant verstärkte apikale Rotation und Torsion. 1 Jahr postoperativ hatte sich die Torsion normalisiert. Bei den Patienten mit Myokardinfarkt zeigte sich nach Revaskularisierung eine Zunahme der Umfangsverkürzung im Infarktareal. Die Quantifizierung der linksventrikulären Wandbewegung mit MR-tagging-Aufnahmen ermöglicht die Charakterisierung und Verlaufsbeobachtungen von Veränderungen der linksventrikulären Wandfunktion bei verschiedenen Herzerkrankungen.
Durch den mehrfachen Führungswechsel in der Radiologischen Abteilung der Frauenklinik der Universität Würzburg seit 1995, ergab sich die Frage, ob die verantwortlichen Radiologen sich in der Mammographiebeurteilung unterscheiden. Ausgehend von 8033 Mammographien von asymptomatischen- und Patientinnen mit einem klinischen Befund, wurde die Sensitivität, Spezifität, die Biopsierate, die Tumorentdeckung- und Recallrate für die einzelnen Untersucher ermittelt. Die wesentlichen Ergebnisse dieser Arbeit sind: 1. Die Sensitivität liegt bei durchschnittlich 97,14%, die Spezifität 98,62%. Die Tumorentdeckungsrate liegt zwischen 6,59‰ und 8,99‰, die Biopsierate beträgt 1,34% und die Recallrate 3,79%. 2. Für alle Behandler liegen diese Werte innerhalb der vom American College of Radiology und den European Guidelines for Quality Assurance in Mammography Screening vorgegebenen Richtlinien. 3. Es gibt keine signifikanten Unterschiede in der Mammographiebefundung durch die verschiedenen Untersucher. 4. Durch die Einführung der standardisierten Klassifikation der Befunde wird in Zukunft eine Qualitätssicherung der Mammographieuntersuchungen und eine Kontrolle der Ergebnisse gewährleistet.
Die T1-Relaxationszeiten der gesunden Kontrollgruppe (Reifgeborene) lag durchschnittlich bei 662 ± 55 ms bei Raumluft und 591 ± 48 ms bei reinem Sauerstoff, die relativen Differenzen bei 10,7 ± 2,3 %. Dies deckt sich mit in der Literatur angegebenen Werten. Die relative Differenz gibt Aufschluss über den Sauerstofftransfer im Blut: je mehr Sauerstoff gelöst im Blut vorliegt, desto niedriger wird der T1-Wert und desto höher die absolute Differenz. Bei der Gruppe der Frühgeborenen mit BPD (Bronchopulmonale Dysplasie) zeigte sich eine geringere relative Differenz (Mittelwert = 9,2 +/- 3,1%) im Vergleich zu dem Mittelwert der Frühgeborenen ohne BPD (10,8 +/- 3,0%) sowie der Reifgeborenen (10,7 +/-2,3%), was auf einen geringeren Sauerstofftransfer in der Lunge schließen lässt. Bei statistischer Auswertung der einzelnen Schichten zeigte sich lediglich in der medialen linken Schicht ein signifikanter Unterschied der relativen Differenz der T1-Werte. Die Differenz war in der Gruppe der Frühgeborenen mit BPD signifikant niedriger als in der Gruppe der Frühgeborenen ohne BPD bzw. der Kontrollgruppe. Bei den ausgewerteten T1-Karten konnten keine lokalen Auffälligkeiten festgestellt werden. Auch morphologisch ergaben sich keinerlei Auffälligkeiten. Es scheint ein globales Problem im Sauerstofftransfer vorzuliegen.
Die Ergebnisse legen nahe, dass bei Kindern, die nach Geburt an einer schweren Form der BPD erkrankt sind, bis zumindest ins Schulkindesalter ein persistierend gestörter Sauerstofftransfer im Lungenparenchym gegeben ist. Diese funktionelle Einschränkung betrifft die gesamte Lunge, die höheren Abweichungen der Messergebnisse in einzelnen Lungenabschnitten bei den ehemaligen Frühgeborenen mit BPD legen eine höhere regionale Diversität nahe. Bei Frühgeborenen ohne chronische Lungenerkrankung sind in MRT-Messungen keine Unterschiede zu Reifgeborenen nachzuweisen. Es ist also anzunehmen, dass nicht allein durch die Frühgeburtlichkeit und das geringe Geburtsgewicht eine obstruktive Einschränkung in der Lungenfunktion als Langzeitfolge im Kindesalter weiter fort besteht, sondern der Faktor der BPD zusätzlich zu einem verminderten Gastransfer in der Lunge führt, welcher am ehesten durch eine verminderte Alveolarisierung und Vaskularisation in der Lunge bedingt ist.
Zusammenfassend lässt sich sagen, dass auch in dieser Studie die MRT bewiesen hat, dass sie eine Diagnostik ist, die aufgrund ihrer vielen Vorteile (röntgenstrahlenfrei, schmerzfrei, hochauflösende Diagnostik) der konventionellen Mammographie überlegen ist. Im Vergleich mit anderen diagnostischen Möglichkeiten, weist die MRT die höchsten Sensitivitäten auf. Viele falsch positive Befunde könnten so vermieden werden und unnötige Biopsien umgangen werden.
Die MRT zeigte in dieser Studie eine Sensitivität von 78%, für reine DCIS 76%.
Die in der präoperativen MR-Diagnostik gemessenen Größen korrelierten statistisch signifikant mit der histologisch bestimmten Größe für alle Gruppen (reines DCIS, begleitendes DCIS, mikroinvasives DCIS) zusammen genommen (c=0,378; p<0,01) sowie für reine DCIS (c=0,403; p<0,05). Desweiteren korrelierten die Größen statistisch signifikant für high-grade DCIS (c=0,493; p<0,05) und für Nekrosen positive DCIS (c=0,556; p<0,01). Hier ließen sich die Tumorgrößen verlässlich vorhersagen.
In der Auswertung der Signalintensitäts-Zeit-Kurven zeigten sich signifikante Unterschiede zwischen den Gruppen hinsichtlich der initialen (p<0,05) und postinitialen Phase (p<0,01). So lässt sich anhand der KM-Kinetik eine Aussage über die Malignität treffen. Ein reines DCIS zeigte typischerweise eine initiale Phase mit einem KM-Anstieg von 50-100% oder >100%, gefolgt von einer Plateau-Phase. Ein invasives Carcinom begleitendes DCIS zeichnete sich durch einen raschen Anstieg >100% gefolgt von einem „wash-out“ und einem inhomogenen, unbegrenzten Anreicherungsverhalten aus. Mikrovinvasive DCIS zeigten ähnlich den reinen DCIS einen initialen Anstieg von 50-100% sowie eine folgende Plateau-Phase.
Keinen statistisch signifikanten Einfluss hatte die präoperative Größenbestimmung auf das operativen Verfahren (BET vs. Ablatio). Trotz der präoperativen MRT waren zu 29,6 % Nachresektionen - davon ca. die Hälfte (14,1%) als sekundäre Ablatio - nötig.
Mit der MRT ließen sich grundsätzlich verlässliche präoperative Vorhersagen hinsichtlich Größe und Malignität treffen. Signalintensitäts-Zeit-Kurven und höhere Feldstärken, wie die 3T-MRT, könnten sehr hilfreich sein und die Sensitivität und Spezifität verbessern. Warum trotz allem noch so viele Nachresektionen nötig sind, gilt es in folgenden Studien zu untersuchen.
Purpose
Repeat surgery in patients with primary hyperparathyroidism (pHPT) is associated with an increased risk of complications and failure. This stresses the need for optimized strategies to accurately localize a parathyroid adenoma before repeat surgery is performed. However, evidence on the extent of required diagnostics for a structured approach is sparse.
Methods
A retrospective single-center evaluation of 28 patients with an indication for surgery due to pHPT and previous thyroid or parathyroid surgery was performed. Diagnostic workup, surgical approach, and outcome in terms of complications and successful removement of parathyroid adenoma with biochemical cure were evaluated.
Results
Neck ultrasound, sestamibi scintigraphy, C11-methionine PET-CT, and selective parathyroid hormone venous sampling, but not MRI imaging, effectively detected the presence of a parathyroid adenoma with high positive predictive values. Biochemical cure was revealed by normalization of calcium and parathormone levels 24-48h after surgery and was achieved in 26/28 patients (92.9%) with an overall low rate of complications. Concordant localization by at least two diagnostic modalities enabled focused surgery with success rates of 100%, whereas inconclusive localization significantly increased the rate of bilateral explorations and significantly reduced the rate of biochemical cure to 80%.
Conclusion
These findings suggest that two concordant diagnostic modalities are sufficient to accurately localize parathyroid adenoma before repeat surgery for pHPT. In cases of poor localization, extended diagnostic procedures are warranted to enhance surgical success rates. We suggest an algorithm for better orientation when repeat surgery is intended in patients with pHPT.
Purpose
The reliable detection of tumor-infiltrated axillary lymph nodes for breast cancer [BC] patients plays a decisive role in further therapy. We aimed to find out whether cross-sectional imaging techniques could improve sensitivity for pretherapeutic axillary staging in nodal-positive BC patients compared to conventional imaging such as mammography and sonography.
Methods
Data for breast cancer patients with tumor-infiltrated axillary lymph nodes having received surgery between 2014 and 2020 were included in this study.
All examinations (sonography, mammography, computed tomography [CT] and magnetic resonance imaging [MRI]) were interpreted by board-certified specialists in radiology. The sensitivity of different imaging modalities was calculated, and binary logistic regression analyses were performed to detect variables influencing the detection of positive lymph nodes.
Results
All included 382 breast cancer patients had received conventional imaging, while 52.61% of the patients had received cross-sectional imaging.
The sensitivity of the combination of all imaging modalities was 68.89%. The combination of MRI and CT showed 63.83% and the combination of sonography and mammography showed 36.11% sensitivity.
Conclusion
We could demonstrate that cross-sectional imaging can improve the sensitivity of the detection of tumor-infiltrated axillary lymph nodes in breast cancer patients. Only the safe detection of these lymph nodes at the time of diagnosis enables the evaluation of the response to neoadjuvant therapy, thereby allowing access to prognosis and improving new post-neoadjuvant therapies.
Background
In wrist arthrograms, aberrant contrast material is frequently seen extending into the soft tissue adjacent to the ulnar styloid process. Since the prestyloid recess can mimic contrast leakage in CT arthrography, this study aims to provide a detailed analysis of its morphologic variability, while investigating whether actual ulnar-sided leakage is associated with injuries of the triangular fibrocartilage complex (TFCC).
Methods
Eighty-six patients with positive wrist trauma history underwent multi-compartment CT arthrography (40 women, median age 44.5 years). Studies were reviewed by two board-certified radiologists, who documented the morphology of the prestyloid recess regarding size, opening type, shape and position, as well as the presence or absence of ulnar-sided contrast leakage. Correlations between leakage and the presence of TFCC injuries were assessed using the mean square contingency coefficient (r\(_{ɸ}\)).
Results
The most common configuration of the prestyloid recess included a narrow opening (73.26%; width 2.26 ± 1.43 mm), saccular shape (66.28%), and palmar position compared to the styloid process (55.81%). Its mean length and anterior–posterior diameter were 6.89 ± 2.36 and 5.05 ± 1.97 mm, respectively. Ulnar-sided contrast leakage was reported in 29 patients (33.72%) with a mean extent of 12.30 ± 5.31 mm. Leakage occurred more often in patients with ulnar-sided TFCC injuries (r\(_{ɸ}\) = 0.480; p < 0.001), whereas no association was found for lesions of the central articular disc (r\(_{ɸ}\) = 0.172; p = 0.111).
Conclusions
Since ulnar-sided contrast leakage is more common in patients with peripheral TFCC injuries, distinction between an atypical configuration of the prestyloid recess and actual leakage is important in CT arthrography of the wrist.
Arterial embolism with lower limb ischemia is a rare manifestation of paraneoplastic hypercoagulability in cancer patients. We report a unique case of fatal thromboembolism involving both circulations associated with a poorly differentiated neuroendocrine tumor of the lung with rapid progress despite high doses of unfractioned heparin and review the current literature on anticoagulative regimen in tumour patients.
Die farbkodierte Duplexsonographie (FKDS) hat sich als nichtinvasive Methode zur Darstellung des Blutflußes innerhalb von Gefäßen sowie von Gefäßveränderungen etabliert. Während gute Ergebnisse der Farbduplexsonographie in großen Gefäßen über 0,51 mm vorliegen, konnte in einer Modellstudie an kleinen Gefäßen unter 0,51 mm festgestellt werden, daß die FKDS in kleineren Gefäßen systematisch zu niedrig mißt. Mit Hilfe des geprüften Echosignalverstärkers kann dieser systematische Fehler nicht behoben werden. Der Einsatz des Echosignalverstärkers bewirkt grundsätzlich nur eine geringe Zunahme der gemessenen Flußgeschwindigkeit. Dies ist unabhängig von dem Gerätetyp und der Schlauchgröße. Der maximale Effekt wird nach 10 bis 60 Sekunden erreicht. Die Messungen der drei Farbdopplergeräte QAD 1 (Firma Philips/Quantum), SONOLINE Elegra (Firma Siemens) und HDI 3000 (Firma Philips/ATL) unterscheiden sich in ihrer Auswertung signifikant. Die Ursache der großen Messdifferenzen unter den Geräte ist endgültig nicht geklärt. Wahrscheinlich liegt die Ursache in der internen Signalverarbeitung der Farbduplexgeräte.
Purpose
The aim of this study was to compare the wave‐CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free‐breathing 4D lung MRI.
Methods
The wave‐CAIPI k‐space trajectory was implemented in a respiratory self‐gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave‐CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study.
Results
The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave‐CAIPI approach. Average normalized mutual information values of the wave‐CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave‐CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave‐CAIPI.
Conclusion
The application of the wave‐CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave‐CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.
Although age is one of the most salient and fundamental aspects of human faces, its processing in the brain has not yet been studied by any neuroimaging experiment. Automatic assessment of temporal changes across faces is a prerequisite to identifying persons over their life-span, and age per se is of biological and social relevance. Using a combination of evocative face morphs controlled for global optical flow and functional magnetic resonance imaging (fMRI), we segregate two areas that process changes of facial age in both hemispheres. These areas extend beyond the previously established face-sensitive network and are centered on the posterior inferior temporal sulcus (pITS) and the posterior angular gyrus (pANG), an evolutionarily new formation of the human brain. Using probabilistic tractography and by calculating spatial cross-correlations as well as creating minimum intersection maps between activation and connectivity patterns we demonstrate a hitherto unrecognized link between structure and function in the human brain on the basis of cognitive age processing. According to our results, implicit age processing involves the inferior temporal sulci and is, at the same time, closely tied to quantity decoding by the presumed neural systems devoted to magnitudes in the human parietal lobes. The ventral portion of Wernicke’s largely forgotten perpendicular association fasciculus is shown not only to interconnect these two areas but to relate to their activations, i.e. to transmit age-relevant information. In particular, post-hoc age-rating competence is shown to be associated with high response levels in the left angular gyrus. Cortical activation patterns related to changes of facial age differ from those previously elicited by other fixed as well as changeable face aspects such as gender (used for comparison), ethnicity and identity as well as eye gaze or facial expressions. We argue that this may be due to the fact that individual changes of facial age occur ontogenetically, unlike the instant changes of gaze direction or expressive content in faces that can be “mirrored” and require constant cognitive monitoring to follow. Discussing the ample evidence for distinct representations of quantitative age as opposed to categorical gender varied over continuous androgyny levels, we suggest that particular face-sensitive regions interact with additional object-unselective quantification modules to obtain individual estimates of facial age.
Die MRT hat die höchste Detektionsrate der radiologischen Verfahren zur Erkennung einer Knochenmarksinfiltration durch das multiple Myelom. In der vorliegenden Studie hatte die T2-w TIRM Sequenz die höchste Sensitivität. Es konnte jedoch kein signifikanter Unterschied zwischen der T2w-TIRM Sequenz und der T1-w TSE Sequenz festgestellt werden. Die Interobservervarianz war in Sitzung 2 (T2-w TIRM Sequenz) und Sitzung 3 (T2-w TIRM/T1-w TSE/KM +T1-w TSE Sequenz) gleichwertig. Durch Kontrastmittelgabe konnte die Sensitivität nicht signifikant verbessert werden. Zusammenfassend bietet die T2-w TIRM Sequenz die Möglichkeit einer ersten schnellen orientierenden Untersuchung. Für ein detailliertes radiologisches Staging, Grading und zum Therapiemonitoring sollte jedoch weiterhin eine MRT-Untersuchung mit T2-w TIRM/T1-w TSE Sequenz plus zusätzlicher Kontrastmittelzugabe erfolgen.
Background:
The amount of fatty degeneration (FD) has major impact on the clinical result and cuff integrity after rotator cuff repair. A quantitative analysis with magnet resonance imaging (MRI) spectroscopy was employed to analyze possible correlation of FD with tendon retraction, tendon thickness and patients’ characteristics in full thickness supraspinatus tears.
Methods:
Forty-two patients with full-thickness supraspinatus tears underwent shoulder MRI including an experimental spectroscopic sequence allowing quantification of the fat fraction in the supraspinatus muscle belly. The amount of fatty degeneration was correlated with tendon retraction, tendon thickness, patients’ age, gender, smoker status, symptom duration and body mass index (BMI). Patients were divided in to three groups of retraction (A) 0-10 mm (n=), (B) 11-20 mm (n=) and (C) < 21 mm (n=) and the means of FD for each group were calculated.
Results:
Tendon retraction (R = 0.6) and symptom duration (R = 0.6) correlated positively, whereas tendon thickness correlated negatively (R = − 0.6) with the amount of FD. The fat fraction increased significantly with tendon retraction: Group (A) showed a mean fat mount of 3.7% (±4%), group (B) of 16.7% (±8.2%) and group (C) of 37.5% (±19%). BMI, age and smoker-status only showed weak to moderate correlation with the amount of FD in this cohort.
Conclusion:
MRI spectroscopy revealed significantly higher amount of fat with increasing grade of retraction, symptom duration and decreased tendon thickness. Thus, these parameters may indirectly be associated with the severity of tendon disease.
Imaging in Vasculitis
(2020)
Purpose of Review: Vasculitides are characterized by mostly autoimmunologically induced inflammatory processes of vascularstructures. They have various clinical and radiologic appearances. Early diagnosis and reliable monitoring are indispensable foradequate therapy to prevent potentially serious complications. Imaging, in addition to laboratory tests and physical examination,constitutes a key component in assessing disease extent and activity. This review presents current standards and some typicalfindings in the context of imaging in vasculitis with particular attention to large vessel vasculitides.
Recent Findings: Recently, imaging has gained importance in the management of vasculitis, especially regarding large vesselvasculitides (LVV). Recently, EULAR (European League Against Rheumatism) has launched its recommendations concerningthe diagnosis of LVVs. Imaging is recommended as the preferred complement to clinical examination. Color-coded duplexsonography is considered the first choice imaging test in suspected giant cell arteritis, and magnetic resonance imaging isconsidered the first choice in suspected Takayasu’sarteritis.
Summary: Due to diversity of clinical and radiologic presentations, diagnosis and therapy monitoring of vasculitides mayconstitute a challenge. As a result of ongoing technological progress, a variety of non-invasive imaging modalities now playan elemental role in the interdisciplinary management of vasculitic diseases.
Background
Salvage radiotherapy (SRT) is clinically established in prostate cancer (PC) patients with PSA persistence or biochemical relapse (BCR) after prior radical surgery. PET/CT imaging prior to SRT may be performed to localize disease recurrence. The recently introduced \(^{68}\)Ga-PSMA outperforms other PET tracers for detection of recurrence and is therefore expected also to impact radiation planning.
Forty-five patients with PSA persistence (16 pts) or BCR (29 pts) after prior prostatectomy, scheduled to undergo SRT of the prostate bed, underwent \(^{68}\)Ga-PSMA PET/CT. The median PSA level was 0.67 ng/ml. The impact of \(^{68}\)Ga-PSMA PET/CT on the treatment decision was assessed. Patients with oligometastatic (≤5 lesions) PC underwent radiotherapy (RT), with the extent of the RT area and dose escalation being based on PET positivity.
Results
Suspicious lesions were detected in 24/45 (53.3 %) patients. In 62.5 % of patients, lesions were only detected by 68Ga-PSMA PET. Treatment was changed in 19/45 (42.2 %) patients, e.g., extending SRT to metastases (9/19), administering dose escalation in patients with morphological local recurrence (6/19), or replacing SRT by systemic therapy (2/19). 38/45 (84.4 %) followed the treatment recommendation, with data on clinical follow-up being available in 21 patients treated with SRT. All but one showed biochemical response (mean PSA decline 78 ± 19 %) within a mean follow-up of 8.12 ± 5.23 months.
Conclusions
\(^{68}\)Ga-PSMA PET/CT impacts treatment planning in more than 40 % of patients scheduled to undergo SRT. Future prospective studies are needed to confirm this significant therapeutic impact on patients prior to SRT.