Refine
Has Fulltext
- yes (155)
Is part of the Bibliography
- yes (155)
Year of publication
Document Type
- Journal article (84)
- Doctoral Thesis (70)
- Preprint (1)
Keywords
- melt electrowriting (13)
- 3D printing (12)
- Knochenzement (12)
- additive manufacturing (10)
- biofabrication (9)
- 3D-Druck (8)
- Hydrogel (7)
- Magnesiumphosphate (7)
- hyaluronic acid (7)
- melt electrospinning writing (7)
- Calciumphosphat (6)
- bioprinting (6)
- Tissue Engineering (5)
- bioink (5)
- polycaprolactone (5)
- tissue engineering (5)
- Biomaterial (4)
- Calciumphosphate (4)
- Knochenkleber (4)
- Knochenzemente (4)
- Polymere (4)
- Struvit (4)
- bone (4)
- bone adhesive (4)
- bone cement (4)
- hydrogel (4)
- hydrogels (4)
- magnesium phosphate cement (4)
- scaffold (4)
- thiol-ene (4)
- Beschichtung (3)
- Biofabrication (3)
- Knochenersatz (3)
- Nanopartikel (3)
- Scaffold (3)
- biomaterials (3)
- breast cancer (3)
- calcium phosphate (3)
- calcium phosphate cement (3)
- chondrogenic differentiation (3)
- electrohydrodynamics (3)
- extracellular matrix (3)
- melt electrowriting (MEW) (3)
- phytic acid (3)
- 3D Bioprinting (2)
- 3D powder printing (2)
- Biodruck (2)
- Biofabrikation (2)
- Calciumhydroxid (2)
- Cement (2)
- Dihydrooxazole (2)
- Electrospinning (2)
- Fluorescence Microscopy (2)
- Gefrierstrukturierung (2)
- Gelatine (2)
- Gerichtete Erstarrung (2)
- Implantat (2)
- Injectability (2)
- Isocyanate (2)
- Knochenersatzmaterial (2)
- MSC (2)
- Makrophagen (2)
- Melt Electrowriting (2)
- Melt electrowriting (2)
- Newberyit (2)
- Oberflächenfunktionalisierung (2)
- Polyethylenglykole (2)
- Polyoxazoline (2)
- Ringöffnungspolymerisation (2)
- Tissue engineering (2)
- Wirkstofffreisetzung (2)
- Zement (2)
- Zementpaste (2)
- angiogenesis (2)
- antibakteriell (2)
- arteriovenous loop (2)
- baghdadite (2)
- biocompatibility (2)
- biomedical materials (2)
- cartilage (2)
- cement (2)
- cortical neurons (2)
- dual setting (2)
- dual setting system (2)
- dual-stage crosslinking (2)
- electrohydrodynamic (2)
- in vitro (2)
- inflammation (2)
- mechanical properties (2)
- polymer processing (2)
- polymer-peptide-conjugate (2)
- premixed (2)
- printability (2)
- rheology (2)
- shape fidelity (2)
- therapy (2)
- zinc (2)
- (AB)\(_{n}\) segmented copolymers (1)
- 2-Aminoethylphosphonic acid (1)
- 316L stainless-steel (1)
- 3D (1)
- 3D Printing (1)
- 3D Pulverdruck (1)
- 3D cultures (1)
- 3D electrophysiology (1)
- 3D microfiber (1)
- 3D model systems (1)
- 3D neuronal networks (1)
- 3D scaffolds (1)
- 3D tumor model (1)
- 3D-Biodruck (1)
- 3d printing (1)
- ACPC (1)
- ALI culture (1)
- Abbindeverhalten (1)
- Additive Fertigung (1)
- Adenovirus (1)
- Adhäsion (1)
- Adipose Tissue (1)
- Alginate-Gelatine (1)
- Amelogenese (1)
- Anisotropic structures (1)
- Antibiotikafreisetzung (1)
- Antibiotikum (1)
- Arteriosklerose (1)
- Artery Models (1)
- Aspergillose (1)
- Aspergillosis (1)
- Atherosclerosis (1)
- Auflösung (1)
- Baghdadit (1)
- Baghdadite (1)
- Beschichtung von Titandioxid-Nanopartikeln (1)
- Biofabrication of hydrogels (1)
- Biofilm (1)
- Bioharz (1)
- Bioink (1)
- Biokeramik (1)
- Biologischer Abbau (1)
- Bioprinting (1)
- Bioresorption (1)
- Biotinte (1)
- Biozement (1)
- Blockcopolymere (1)
- Bone Cement (1)
- Bone marrow (1)
- Bone-replacement (1)
- Boolesches Netz (1)
- Breast cancer (1)
- Bruschitbeschichtung (1)
- Brustkrebs (1)
- Ca\(^{2+}\)-Imaging (1)
- Calcium Phosphate (1)
- Calcium phosphate (1)
- Calcium phosphate-based biomaterials (1)
- Calcium-Magnesium-Phosphat-Zemente (1)
- Calcium-Magnesium-Phosphates-Cements (1)
- Calciummagnesiumphosphat (1)
- Calciummagnesiumphosphat-Keramik (1)
- Calciumphosphatzemente (1)
- Cartilage (1)
- Cell Sheet Engineering (1)
- Cell adhesion (1)
- Cement Paste (1)
- Ceramic polymer composite (1)
- Chelatbildner (1)
- Chemical modification of biopolymers (1)
- Chondrogenesis (1)
- Chondrogenic differentiation (1)
- Chondrozyten (1)
- Co-Kultur (1)
- Colloidal Stability (1)
- Correlative microscopy (1)
- DLP-SLA (1)
- Dectin-1 (1)
- Degradation (1)
- Druckbarkeit (1)
- Dual setting system (1)
- Dual-setting (1)
- ECM (1)
- Elektrochemische Abscheidung (1)
- Elektrospinnen (1)
- Elektrostatisches Verspinnen (1)
- Endodontie (1)
- Endoprothese (1)
- Extrazelluläre Matrix (1)
- Extrazellulärmatrix (1)
- Fettgewebe (1)
- Fibrin (1)
- Fibroblast (1)
- Fibroblasten (1)
- FluidFM (1)
- FluidFM technology (1)
- Fluoreszenzmarkierung (1)
- Freeze-Structuring (1)
- Freezing (1)
- Functional hydrophilic polymers (1)
- Funktionalisierung <Chemie> (1)
- Funktionalisierung von elektrogesponnenen Fasern (1)
- Funktionswerkstoff (1)
- Galvanische Abscheidung (1)
- GelAGE (1)
- GelMA (1)
- Gene therapy (1)
- Genregulation (1)
- Gewebe (1)
- Geweberegeneration (1)
- Glycidol (1)
- Gold-Nanoparticles (1)
- Granulat (1)
- Granulate (1)
- Granules (1)
- HA modifiedCNF membranes (1)
- HASH (1)
- HEMA (1)
- Hemodynamics (1)
- Hyaluronic Acid (1)
- Hyaluronsäure (1)
- Hydroxylapatit (1)
- Hypertrophy (1)
- Hämodynamik (1)
- IP6 (1)
- Implantatwerkstoff (1)
- In vitro model (1)
- In vivo (1)
- Inhibition (1)
- Injizierbarkeit (1)
- Iron Oxide Nanoparticles (1)
- Janus fibers (1)
- Klebstoff (1)
- Knochen (1)
- Knochenbruch (1)
- Knochenwachs (1)
- Knorpel (1)
- Konjugate (1)
- Korrelative Mikroskopie (1)
- Kupfer (1)
- L929 (1)
- Lactobacillus acidophilus (1)
- Laktobazillen (1)
- MPI (1)
- MPS (1)
- MRI (1)
- Macrophage extracellular traps (1)
- Magnesiumoxid (1)
- Magnesiumphosphat (1)
- Magnesiumphosphatschäume (1)
- Mechanische Aktivierung (1)
- Melt electrospinning (1)
- Mesenchymal stem cell (1)
- Mesenchymale Stromazellen (1)
- Mikrofluidik (1)
- Mikrotumormodell (1)
- Milchsäure (1)
- Milchsäurebakterien (1)
- Modification (1)
- Modifikation (1)
- Modifikation von Biokeramiken (1)
- Morphology (1)
- Multifunctionalisability (1)
- NANOG (1)
- NCO-sP(EO-stat-PO) (1)
- NLRP3 (1)
- Nahtmaterial (1)
- Nanofaser (1)
- Nanogels (1)
- Nanohydrogel (1)
- Nanoparticle Tracking Analysis (1)
- Nanoparticles (1)
- Nanopartikelcharakterisierung (1)
- Nanoröhre (1)
- Nanotubular coatings (1)
- Nanotubuläre Beschichtungen (1)
- Normal breast (1)
- Orale Chirurgie, (1)
- Osteoblast (1)
- Osteochondrales Gewebe (1)
- Osteoklast (1)
- Osteoklastendifferenzierung (1)
- Oxygen diffusion hardening (1)
- PCL (1)
- PEG (1)
- PLGA (1)
- PTEN (1)
- PVD Beschichtung (1)
- PVD coatings (1)
- PVD-Verfahren (1)
- Paste (1)
- Pharmaceutics (1)
- Phosphoserin (1)
- Photopolymerisation (1)
- Poly(2-oxazoline) (1)
- Poly(glycidol)s (1)
- Polyacrylsäure (1)
- Polyacrylsäuren (1)
- Polycaprolacton (1)
- Polyglycidol (1)
- Polylactid-co-Glycolid (1)
- Polymer-Gel (1)
- Polymer-peptide-conjugate (1)
- Polymergehalt (1)
- Polymers (1)
- Polymilchsäure (1)
- Polyoxazolines (1)
- Primary cell lines (1)
- QCM (1)
- RAFT (1)
- RHO (1)
- ROCK (1)
- Rapid Prototyping <Fertigung> (1)
- Regeneration (1)
- Reißfestigkeit (1)
- Rheologie (1)
- Rheology (1)
- S.aureus (1)
- SOX9 (1)
- Sauerstoffdiffusionshärtung (1)
- Scaffold <Tissue Engineering> (1)
- Schiff base chemistry (1)
- Schleuderguss (1)
- Setting Control (1)
- Silber (1)
- Silberdotierung (1)
- Silica precursor (1)
- Sol-gel (1)
- Stanfieldit (1)
- Staphylococcus aureus / drug effects (1)
- Star-shaped poly(ethylene glycol) (1)
- Stem cells plasticity (1)
- Sternpolymere (1)
- Strontium (1)
- Tantal (1)
- Therapeutisches System (1)
- Thermoresponsive Polymere (1)
- Thioether-Poly(glycidol) (1)
- Ti(Ag) Beschichtungen (1)
- Ti(Ag) coatings (1)
- Tierversuch (1)
- Titan (1)
- Titandioxid (1)
- Titanimplantat (1)
- Tricalciumphosphatkeramik (1)
- Tumormicroenvironment (1)
- Tumorstammzellen (1)
- UV-VIS-Spektroskopie (1)
- Unidirectional Freezing (1)
- Universität Würzburg. Lehrstuhl für Bioinformatik (1)
- Vancomycin / administration & dosage (1)
- Vancomycin / chemistry (1)
- Vancomycin / pharmacology (1)
- Vascularization (1)
- Vaskularisation (1)
- Verbundwerkstoff (1)
- Vereinzelung von Partikeln (1)
- Volumetrischer Biodruck (1)
- WST test (1)
- Wasserlösliche Polymere (1)
- Wirkstoff-Träger-System (1)
- Wundinfektion (1)
- Wundnaht (1)
- ZIP (1)
- Zahnentwicklung (1)
- Zahnimplantat (1)
- Zahnmedizin (1)
- Zetapotential (1)
- Zink (1)
- acrylate-endcapped urethane-based polymer (AUP) (1)
- actin (1)
- acute myeloid leukaemia (1)
- adhesion dynamics (1)
- adhesive (1)
- adipose tissue (1)
- adipose-derived stromal cells (1)
- agarose (1)
- alginate (1)
- alveolar‐capillary barrier (1)
- amoeboid cell migration (1)
- animal model (1)
- anisotropic porous structures (1)
- anti-bacterial agents / administration & dosage (1)
- anti-bacterial agents / chemistry (1)
- anti-bacterial agents / pharmacology (1)
- antibacterial (1)
- antiinflammatorisch (1)
- arthritis (1)
- artificial bones (1)
- astrocytes (1)
- atomic force microscopy (1)
- axial vascularization (1)
- azlactone (1)
- balloon kyphoplasty (1)
- bending strength (1)
- bio-printability (1)
- bioceramic (1)
- bioceramics (1)
- biocompatible Materials (1)
- biodegradable polymer (1)
- biodegradable polymers (1)
- biofabricated vascular graft (1)
- biofunctional coating (1)
- bioinorganic (1)
- bioinspired interface (1)
- bioinspired membrane (1)
- biological models (1)
- biomaterial ink (1)
- biomechanical evaluation (1)
- biomechanics (1)
- biomedical engineering (1)
- biophysics (1)
- biosensor (1)
- biosensors (1)
- blood-plasma (1)
- bohrbar (1)
- bone and cartilage tissue engineering (1)
- bone critical size defect (1)
- bone glue (1)
- bone graft substitutes (1)
- bone wax (1)
- bone wires (1)
- brain cancer (1)
- breast cancer model (1)
- brushite cement (1)
- brushite coating (1)
- calcaneus (1)
- calcium phosphate cements (1)
- calcium-phosphate (1)
- calciumhydroxide (1)
- carbon fiber reinforcement (1)
- cardiovascular pharmacology (1)
- cartilage repair (1)
- cell coagulation (1)
- cell counting (1)
- cell elongation (1)
- cell guidance (1)
- cell migration (1)
- cell morphology (1)
- cell printing (1)
- cell self-assembled monolayers (1)
- cell transplantation (1)
- cell viability (1)
- cement paste (1)
- cements (1)
- centrifugally casting (1)
- ceramic polymer composite (1)
- ceramics (1)
- chemical crosslinking (1)
- chemokines (1)
- chemoselective (1)
- chemosensitivity (1)
- chondrocyte (1)
- chondrocytes (1)
- chondroprogenitors (1)
- click chemistry (1)
- co-culture (1)
- coating (1)
- coatings (1)
- cochlea (1)
- collagen (1)
- collagen sponge (1)
- combination of physical vapor deposition and electrochemical etching (1)
- composite material (1)
- compressive strength (1)
- connective tissue (1)
- copper (1)
- crosslinked coating (1)
- cryostructured scaffolds (1)
- cyclic mechanical stretch (1)
- cyclic stretch (1)
- cyclic testing (1)
- cyto-compatibility (1)
- cytotoxicity (1)
- damage tolerant cement (1)
- deafness (1)
- defects (1)
- defined humanized test system (1)
- definition (1)
- degradable bone substitutes (1)
- degradable implant (1)
- degradation (1)
- detachment force quantification (1)
- dicalcium phosphate cement (1)
- differentation (1)
- digitization (1)
- dihydrate cement (1)
- directional solidification (1)
- disease models (1)
- drillable (1)
- drillable bone cement (1)
- drop on demand (1)
- drug delivery (1)
- drug liberation (1)
- drug release (1)
- dual abbindend (1)
- durotaxis (1)
- electroactive (1)
- electroactive polymers (1)
- electrochemical deposition (1)
- electrochemically surface coating (1)
- electron microscopy (1)
- electrospinning (1)
- electrospun fibers (1)
- elektrochemische Oberflächenbeschichtung (1)
- eletrhydrodynamic (1)
- embedded templating (1)
- endothelial progenitor cells (1)
- expression (1)
- extrusion of hiMPC-containing bioinks alginate + collagen type I (1)
- extrusion-based 3D printing (1)
- factor-I (1)
- farringtonite (1)
- fiber (1)
- fiber reinforcement (1)
- fibers (1)
- fiber–matrix interaction (1)
- fixation (1)
- focal adhesions (1)
- force (1)
- fracture (1)
- free radical polymerization (1)
- functionalization (1)
- funktionale Präpolymere (1)
- gels (1)
- gels and hydrogels (1)
- genregulatorisches Netzwerk (1)
- gentamicin-loaded poly (methyl methacrylate) bone cement (1)
- granules (1)
- growth (1)
- guided bone regeneration (1)
- heart-failure (1)
- hemocompatibility (1)
- heterotypic scaffold design (1)
- human iPSC-derived mesodermal cells (hiMPCs) (1)
- human macrophages (1)
- human neutrophil elastase (HNE) (1)
- hybrid fabrication (1)
- hybrid materials (1)
- hybrid polymers (1)
- hydraulic reactivity (1)
- hydrogel formation (1)
- hydrophilic polymers (1)
- hydroxyapatite (1)
- hypoxia (1)
- imaging agents (1)
- immunomodulation (1)
- implant (1)
- implants (1)
- in vitro cell‐stretch model (1)
- in-vitro-Modell (1)
- in-vivo Micro-Computed Tomography (1)
- inflammatory response (1)
- injectability (1)
- injectable paste (1)
- injizierbare Paste (1)
- inner ear (1)
- inositol hexaphosphate (1)
- intercellular adhesion (1)
- interface control (1)
- iron release (1)
- lectin (1)
- left-ventricular function (1)
- load to failure testing (1)
- local drug delivery (1)
- lung cell model (1)
- macrophage polarization (1)
- macrophages (1)
- magnesium phosphate (1)
- magnetic properties (1)
- magnetoactive materials (1)
- materials testing (1)
- mature cell-cell contacts (1)
- mechanical activation (1)
- mechanical performance (1)
- mechanical reinforcement (1)
- mechanische Eigenschaften (1)
- medical device (1)
- medical-grade poly(ε-caprolactone) (1)
- medicine (1)
- melanoma (1)
- melt electrowriting (1)
- melt electrofibrillation (1)
- melt electrospinning (1)
- mesenchymal stem cells (1)
- mesenchymale Stromazellen (1)
- microfibers (1)
- microfibres (1)
- microfluidics (1)
- microstructures (1)
- microvasculature (1)
- migration (1)
- minipig (1)
- modelling (1)
- morphology controls (1)
- mucin (1)
- multilayered vessel wall with intimate, media and adventitia (1)
- nanofibers (1)
- nanostructures (1)
- nanotopographical surfaces (1)
- native chemical ligation (1)
- networks (1)
- neurite growth (1)
- organ-on-a-chip (1)
- organoids (1)
- organophosphates (1)
- osseointegration (1)
- osteoblasts (1)
- osteochondral defect (1)
- osteoporosis (1)
- oxidation (1)
- particle study (1)
- peptide conjugation (1)
- peptide immobilization (1)
- periprosthetic infection (1)
- periprothetische Infektion (1)
- phase conversion (1)
- photo-crosslinking (1)
- photopolymerization (1)
- physicochemical characterization (1)
- plasticizers (1)
- platelet-adhesion (1)
- platelets (1)
- poly(2-ethyl-2-oxazoline) (1)
- poly(2-oxazoline)s (1)
- poly(ethylene glycol) (1)
- poly(glycidol) (1)
- poly(lactic-co-glycolic acid) (1)
- poly(lactide-co-glycolide) (1)
- polyacrylic acid (1)
- polyethylene glycol (1)
- polyethylenglykole (1)
- polyglycidol (1)
- polylactid (1)
- polymer (1)
- polymer-analogue functionalization (1)
- polymeric matrix (1)
- polymers (1)
- polyoxazoline (1)
- polyoxazolines (1)
- porosity (1)
- postsurgical adhesion (1)
- pre-crosslinking (1)
- premixed paste (1)
- primary vascular smooth muscle‐like cells (vSMCs) (1)
- proliferation (1)
- proosseointegrativ (1)
- properties (1)
- prostheses and implants (1)
- protein adsorption (1)
- präfabriziert (1)
- präfabrizierte Paste (1)
- radiopacity (1)
- rat model (1)
- recruitment (1)
- remodelling (1)
- repair (1)
- rhBMP–2 (1)
- ring opening polymerisation (1)
- ring-opening polymerization (1)
- sPEG (1)
- sacrificial printing (1)
- sanders (1)
- scaffolds (1)
- screw (1)
- self-assembled monolayers (1)
- serial block face EM (1)
- setting reaction (1)
- shear stress (1)
- shear thinning (1)
- signaling (1)
- silicones (1)
- silver doped titanium dioxide nanoparticles (1)
- sodium alginate (1)
- solution electrospinning (1)
- spherical granules (1)
- spheroids (1)
- sphärische Granulate (1)
- spinning (1)
- stanfieldite (1)
- starPEG (1)
- starPEG hydrogel (1)
- stem cells (1)
- stimulation (1)
- stress (1)
- strontiumdotierte Struvitschichten (1)
- subcutaneous implanation (1)
- sugar glass printing (1)
- surface coating (1)
- surface functionalisation (1)
- surface functionalization (1)
- surfaces (1)
- sutures (1)
- synbones (1)
- synergistic reinforcement (1)
- synthetic hydrogels (1)
- systematic investigations (1)
- tension (1)
- testing (1)
- testing methods (1)
- tethering (1)
- thermoresponsive hydrogel (1)
- thrombin (1)
- thrombosis (1)
- tibial head depression fracture (1)
- tissue morphogenesis (1)
- tissue regeneration (1)
- titanium implant (1)
- topotaxis (1)
- total joint arthroplasty (1)
- total knee arthroplasty (1)
- traction (1)
- tranexamic acid (1)
- transforming growth factor-beta 1 (1)
- transplantation (1)
- tricalcium phosphate (1)
- tubular constructs (1)
- tumor heterogeneity (1)
- tunable ultra‐thin biphasic membrane (1)
- unidirectional freezing (1)
- vascular biofabrication (1)
- vascular network and hierarchical organized vessels (1)
- vorgemischt (1)
- x-ray micro computed tomography (1)
- zetapotential (1)
- zonal (1)
- zonal construct (1)
- α-tricalcium phosphate (1)
- α‑Tricalciumphosphat (1)
Institute
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (155) (remove)
Sonstige beteiligte Institutionen
Electrospun carbon nanofibers (CNFs), which were modified with hydroxyapatite, were fabricated to be used as a substrate for bone cell proliferation. The CNFs were derived from electrospun polyacrylonitrile (PAN) nanofibers after two steps of heat treatment: stabilization and carbonization. Carbon nanofibrous (CNF)/hydroxyapatite (HA) nanocomposites were prepared by two different methods; one of them being modification during electrospinning (CNF-8HA) and the second method being hydrothermal modification after carbonization (CNF-8HA; hydrothermally) to be used as a platform for bone tissue engineering. The biological investigations were performed using in-vitro cell counting, WST cell viability and cell morphology after three and seven days. L929 mouse fibroblasts were found to be more viable on the hydrothermally-modified CNF scaffolds than on the unmodified CNF scaffolds. The biological characterizations of the synthesized CNF/HA nanofibrous composites indicated higher capability of bone regeneration.
Animal models are important tools to investigate the pathogenesis and develop treatment strategies for breast cancer in humans. In this study, we developed a new three-dimensional in vivo arteriovenous loop model of human breast cancer with the aid of biodegradable materials, including fibrin, alginate, and polycaprolactone. We examined the in vivo effects of various matrices on the growth of breast cancer cells by imaging and immunohistochemistry evaluation. Our findings clearly demonstrate that vascularized breast cancer microtissues could be engineered and recapitulate the in vivo situation and tumor-stromal interaction within an isolated environment in an in vivo organism. Alginate–fibrin hybrid matrices were considered as a highly powerful material for breast tumor engineering based on its stability and biocompatibility. We propose that the novel tumor model may not only serve as an invaluable platform for analyzing and understanding the molecular mechanisms and pattern of oncologic diseases, but also be tailored for individual therapy via transplantation of breast cancer patient-derived tumors.
Within this thesis, three main approaches for the assessment and investigation of altered hemodynamics like wall shear stress, oscillatory shear index and the arterial pulse wave velocity in atherosclerosis development and progression were conducted:
1. The establishment of a fast method for the simultaneous assessment of 3D WSS and PWV in the complete murine aortic arch via high-resolution 4D-flow MRI
2. The utilization of serial in vivo measurements in atherosclerotic mouse models using high-resolution 4D-flow MRI, which were divided into studies describing altered hemodynamics in late and early atherosclerosis
3. The development of tissue-engineered artery models for the controllable application and variation of hemodynamic and biologic parameters, divided in native artery models and biofabricated artery models, aiming for the investigation of the relationship between atherogenesis and hemodynamics
Chapter 2 describes the establishment of a method for the simultaneous measurement of 3D WSS and PWV in the murine aortic arch at, using ultra high-field MRI at 17.6T [16], based on the previously published method for fast, self-navigated wall shear stress measurements in the murine aortic arch using radial 4D-phase contrast MRI at 17.6 T [4]. This work is based on the collective work of Dr. Patrick Winter, who developed the method and the author of this thesis, Kristina Andelovic, who performed the experiments and statistical analyses. As the method described in this chapter is basis for the following in vivo studies and undividable into the sub-parts of the contributors without losing important information, this chapter was not split into the single parts to provide fundamental information about the measurement and analysis methods and therefore better understandability for the following studies. The main challenge in this chapter was to overcome the issue of the need for a high spatial resolution to determine the velocity gradients at the vascular wall for the WSS quantification and a high temporal resolution for the assessment of the PWV without prolonging the acquisition time due to the need for two separate measurements. Moreover, for a full coverage of the hemodynamics in the murine aortic arch, a 3D measurement is needed, which was achieved by utilization of retrospective navigation and radial trajectories, enabling a highly flexible reconstruction framework to either reconstruct images at lower spatial resolution and higher frame rates for the acquisition of the PWV or higher spatial resolution and lower frame rates for the acquisition of the 3D WSS in a reasonable measurement time of only 35 minutes. This enabled the in vivo assessment of all relevant hemodynamic parameters related to atherosclerosis development and progression in one experimental session. This method was validated in healthy wild type and atherosclerotic Apoe-/- mice, indicating no differences in robustness between pathological and healthy mice.
The heterogeneous distribution of plaque development and arterial stiffening in atherosclerosis [10, 12], however, points out the importance of local PWV measurements. Therefore, future studies should focus on the 3D acquisition of the local PWV in the murine aortic arch based on the presented method, in order to enable spatially resolved correlations of local arterial stiffness with other hemodynamic parameters and plaque composition.
In Chapter 3, the previously established methods were used for the investigation of changing aortic hemodynamics during ageing and atherosclerosis in healthy wild type and atherosclerotic Apoe-/- mice using the previously established methods [4, 16] based on high-resolution 4D-flow MRI. In this work, serial measurements of healthy and atherosclerotic mice were conducted to track all changes in hemodynamics in the complete aortic arch over time. Moreover, spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated. This important feature allowed for the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and most importantly – at a glance. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, with decreasing longWSS and increasing OSI, while showing constant PWV in healthy mice and increasing longWSS and decreasing OSI, while showing increased PWV in diseased mice. Moreover, spatially resolved correlations between WSS, PWV, plaque and vessel wall characteristics were enabled, giving detailed insights into coherences between hemodynamics and plaque composition. Here, the circWSS was identified as a potential marker of plaque size and composition in advanced atherosclerosis. Moreover, correlations with PWV values identified the maximum radStrain could serve as a potential marker for vascular elasticity. This study demonstrated the feasibility and utility of high-resolution 4D flow MRI to spatially resolve, visualize and analyze statistical differences in all relevant hemodynamic parameters over time and between healthy and diseased mice, which could significantly improve our understanding of plaque progression towards vulnerability. In future studies the relation of vascular elasticity and radial strain should be further investigated and validated with local PWV measurements and CFD.
Moreover, the 2D histological datasets were not reflecting the 3D properties and regional characteristics of the atherosclerotic plaques. Therefore, future studies will include 3D plaque volume and composition analysis like morphological measurements with MRI or light-sheet microscopy to further improve the analysis of the relationship between hemodynamics and atherosclerosis.
Chapter 4 aimed at the description and investigation of hemodynamics in early stages of atherosclerosis. Moreover, this study included measurements of hemodynamics at baseline levels in healthy WT and atherosclerotic mouse models. Due to the lack of hemodynamic-related studies in Ldlr-/- mice, which are the most used mouse models in atherosclerosis research together with the Apoe-/- mouse model, this model was included in this study to describe changing hemodynamics in the aortic arch at baseline levels and during early atherosclerosis development and progression for the first time. In this study, distinct differences in aortic geometries of these mouse models at baseline levels were described for the first time, which result in significantly different flow- and WSS profiles in the Ldlr-/- mouse model. Further basal characterization of different parameters revealed only characteristic differences in lipid profiles, proving that the geometry is highly influencing the local WSS in these models. Most interestingly, calculation of the atherogenic index of plasma revealed a significantly higher risk in Ldlr-/- mice with ongoing atherosclerosis development, but significantly greater plaque areas in the aortic arch of Apoe-/- mice. Due to the given basal WSS and OSI profile in these two mouse models – two parameters highly influencing plaque development and progression – there is evidence that the regional plaque development differs between these mouse models during very early atherogenesis.
Therefore, future studies should focus on the spatiotemporal evaluation of plaque development and composition in the three defined aortic regions using morphological measurements with MRI or 3D histological analyses like LSFM. Moreover, this study offers an excellent basis for future studies incorporating CFD simulations, analyzing the different measured parameter combinations (e.g., aortic geometry of the Ldlr-/- mouse with the lipid profile of the Apoe-/- mouse), simulating the resulting plaque development and composition. This could help to understand the complex interplay between altered hemodynamics, serum lipids and atherosclerosis and significantly improve our basic understanding of key factors initiating atherosclerosis development.
Chapter 5 describes the establishment of a tissue-engineered artery model, which is based on native, decellularized porcine carotid artery scaffolds, cultured in a MRI-suitable bioreactor-system [23] for the investigation of hemodynamic-related atherosclerosis development in a controllable manner, using the previously established methods for WSS and PWV assessment [4, 16]. This in vitro artery model aimed for the reduction of animal experiments, while simultaneously offering a simplified, but completely controllable physical and biological environment. For this, a very fast and gentle decellularization protocol was established in a first step, which resulted in porcine carotid artery scaffolds showing complete acellularity while maintaining the extracellular matrix composition, overall ultrastructure and mechanical strength of native arteries. Moreover, a good cellular adhesion and proliferation was achieved, which was evaluated with isolated human blood outgrowth endothelial cells. Most importantly, an MRI-suitable artery chamber was designed for the simultaneous cultivation and assessment of high-resolution 4D hemodynamics in the described artery models. Using high-resolution 4D-flow MRI, the bioreactor system was proven to be suitable to quantify the volume flow, the two components of the WSS and the radStrain as well as the PWV in artery models, with obtained values being comparable to values found in literature for in vivo measurements. Moreover, the identification of first atherosclerotic processes like intimal thickening is achievable by three-dimensional assessment of the vessel wall morphology in the in vitro models. However, one limitation is the lack of a medial smooth muscle cell layer due to the dense ECM. Here, the utilization of the laser-cutting technology for the generation of holes and / or pits on a microscale, eventually enabling seeding of the media with SMCs showed promising results in a first try and should be further investigated in future studies. Therefore, the proposed artery model possesses all relevant components for the extension to an atherosclerosis model which may pave the way towards a significant improvement of our understanding of the key mechanisms in atherogenesis.
Chapter 6 describes the development of an easy-to-prepare, low cost and fully customizable artery model based on biomaterials. Here, thermoresponsive sacrificial scaffolds, processed with the technique of MEW were used for the creation of variable, biomimetic shapes to mimic the geometric properties of the aortic arch, consisting of both, bifurcations and curvatures. After embedding the sacrificial scaffold into a gelatin-hydrogel containing SMCs, it was crosslinked with bacterial transglutaminase before dissolution and flushing of the sacrificial scaffold. The hereby generated channel was subsequently seeded with ECs, resulting in an easy-to-prepare, fast and low-cost artery model. In contrast to the native artery model, this model is therefore more variable in size and shape and offers the possibility to include smooth muscle cells from the beginning. Moreover, a custom-built and highly adaptable perfusion chamber was designed specifically for the scaffold structure, which enabled a one-step creation and simultaneously offering the possibility for dynamic cultivation of the artery models, making it an excellent basis for the development of in vitro disease test systems for e.g., flow-related atherosclerosis research. Due to time constraints, the extension to an atherosclerosis model could not be achieved within the scope of this thesis. Therefore, future studies will focus on the development and validation of an in vitro atherosclerosis model based on the proposed bi- and three-layered artery models.
In conclusion, this thesis paved the way for a fast acquisition and detailed analyses of changing hemodynamics during atherosclerosis development and progression, including spatially resolved analyses of all relevant hemodynamic parameters over time and in between different groups. Moreover, to reduce animal experiments, while gaining control over various parameters influencing atherosclerosis development, promising artery models were established, which have the potential to serve as a new platform for basic atherosclerosis research.
In vitro models mimic the tissue-specific anatomy and play essential roles in personalized medicine and disease treatments. As a sophisticated manufacturing technology, 3D printing overcomes the limitations of traditional technologies and provides an excellent potential for developing in vitro models to mimic native tissue. This thesis aims to investigate the potential of a high-resolution 3D printing technology, melt electrowriting (MEW), for fabricating in vitro models. MEW has a distinct capacity for depositing micron size fibers with a defined design. In this thesis, three approaches were used, including 1) extending the MEW polymer library for different biomedical applications, 2) developing in vitro models for evaluation of cell growth and migration toward the different matrices, and 3) studying the effect of scaffold designs and biochemical cues of microenvironments on cells.
First, we introduce the MEW processability of (AB)n and (ABAC)n segmented copolymers, which have thermally reversible network formulation based on physical crosslinks. Bisurea segments are combined with hydrophobic poly(dimethylsiloxane) (PDMS) or hydrophilic poly(propylene oxide)-poly(ethylene oxide)-poly(propylene oxide) (PPO-PEG-PPO) segments to form the (AB)n segmented copolymers. (ABAC)n segmented copolymers contain all three segments: in addition to bisurea, both hydrophobic and hydrophilic segments are available in the same polymer chain, resulting in tunable mechanical and biological behaviors. MEW copolymers either support cells attachment or dissolve without cytotoxic side effects when in contact with the polymers at lower concentrations, indicating that this copolymer class has potential in biological applications. The unique biological and surface properties, transparency, adjustable hydrophilicity of these copolymers could be beneficial in several in vitro models.
The second manuscript addresses the design and development of a melt electrowritten competitive 3D radial migration device. The approach differs from most of the previous literature, as MEW is not used here to produce cell invasive scaffolds but to fabricate an in vitro device. The device is utilized to systematically determine the matrix which promotes cell migration and growth of glioblastoma cells. The glioblastoma cell migration is tested on four different Matrigel concentrations using a melt electrowritten radial device. The glioblastoma U87 cell growth and migration increase at Matrigel concentrations 6 and 8 mg mL-1 In the development of this radial device, the accuracy, and precision of melt electrowritten circular shapes were investigated. The results show that the printing speed and design diameter are essential parameters for the accuracy of printed constructs. It is the first instance where MEW is used for the production of in vitro devices.
The influence of biochemical cues and scaffold designs on astrocytes and glioblastoma is investigated in the last manuscript. A fiber comprising the box and triangle-shaped pores within MEW scaffolds are modified with biochemical cues, including RGD and IKVAV peptides using a reactive NCO-sP(EO-stat-PO) macromer. The results show that astrocytes and glioblastoma cells exhibit different phenotypes on scaffold designs and peptide-coated scaffolds.
Various (AB)\(_{n}\) and (ABAC)\(_{n}\) segmented copolymers with hydrophilic and hydrophobic segments are processed via melt electrowriting (MEW). Two different (AB)\(_{n}\) segmented copolymers composed of bisurea segments and hydrophobic poly(dimethyl siloxane) (PDMS) or hydrophilic poly(propylene oxide)-poly(ethylene oxide)-poly(propylene oxide) (PPO-PEG-PPO) segments, while the amphiphilic (ABAC)\(_{n}\) segmented copolymers consist of bisurea segments in the combination of hydrophobic PDMS segments and hydrophilic PPO-PEG-PPO segments with different ratios, are explored. All copolymer compositions are processed using the same conditions, including nozzle temperature, applied voltage, and collector distance, while changes in applied pressure and collector speed altered the fiber diameter in the range of 7 and 60 µm. All copolymers showed excellent processability with MEW, well-controlled fiber stacking, and inter-layer bonding. Notably, the surfaces of all four copolymer fibers are very smooth when visualized using scanning electron microscopy. However, the fibers show different roughness demonstrated with atomic force microscopy. The non-cytotoxic copolymers increased L929 fibroblast attachment with increasing PDMS content while the different copolymer compositions result in a spectrum of physical properties.
Biomimetic calcium phosphate (CaP) coatings imitate the trabecular bones surface structure and have shown to promote osteogenic differentiation in multipotent cells. The work of this thesis focused on the problem of former CaP coatings cracking and flaking off when being put on a bendable core structure like a 3D-printed poly (ε-caprolactone) (PCL) scaffold. The aim was to provide a chemical linkage between PCL and CaP using a star-shaped polymer (sPEG) and a phosphonate, 2-aminoethylphosphonic acid (2-AEP). First, a published CaP coating protocol was revised and investigated in terms of etching parameters for the PCL scaffold. Results presented reproducible thick coatings for all groups. The protocol was then broadened to include subsequent scaffold incubation in sPEG and 2-AEP solutions. Homogenous CaP coatings of decreased thickness presented themselves, proving feasibility. However, as is often found with physical CaP coating depositions, there were some irregular outcomes even during the same experimental group. A lower consumption of the chemical 2-AEP, for economic reasons, meant that the protocol was altered to simultaneously incubate scaffolds with sPEG and 2-AEP including preceding calculations for molar ratios. For ratios 1:1, 1:2 and 1:3, again a homogenous CaP coating was produced on most of the samples, although reproducibility issues maintained. However, the mechanical bending to induce surface cracking showed that the CaP did strongly bond to the sPEG/2-AEP, while the control CaP coating flaked off the surface in large pieces. This research demonstrates that chemically-bound CaP coatings resist flaking off the fiber surface. Future investigations should focus on the mechanisms of CaP crystallization, to improve reproducibility.
Ziel der vorliegenden Arbeit war die Herstellung und Erprobung von innovativen Anwendungsformen kalthärtender Knochenersatzmaterialien aus Calcium-, und Magnesiumphosphaten, die nach dem Abbindevorgang vorzugsweise aus dem Mineral Struvit (MgNH4PO4·6H2O) bestehen. Diese neuartigen Knochenzemente versprechen im Vergleich zu den herkömmlichen Knochenersatzmaterialien eine deutlich schnellere knöcherne Regeneration und Abbaubarkeit. Damit wird das Ziel verfolgt schneller Implantate setzen zu können und dem Patienten somit eine lange Wartezeit und dementsprechenden Leidensdruck ersparen zu können. Ebenso müssen konventionelle Produkte erst im OP angerührt und hiernach in einem schmalen Zeitfenser verarbeitet werden. Die präfabrizierten Zement-Pasten sind dagegen direkt applikationsbereit und härten erst nach Kontakt mit dem feuchten Milieu aus. In vorangegangenen Projekten wurden sowohl präfabrizierte Pasten als auch Granulate auf Basis Struvit-bildender Calcium-Magnesiumphosphate erfolgreich entwickelt. Vorteil dieser Granulate ist ihre sphärische Form. Im Hinblick auf die klinische Anwendbarkeit sollten in der vorliegenden Studie beide Anwendungsformen vorgreifend auf eine tierexperimentelle Studie hinsichtlich ihrer Materialeigenschaften in vitro getestet werden.
Aim of this thesis was the development of functionalizable hydrogel coatings for melt electrowritten PCL scaffolds and of bioprintable hydrogels for biofabrication.
Hydrogel coatings of melt electrowritten scaffolds enabled to control the surface hydrophilicity, thereby allowing cell-material interaction studies of biofunctionalized scaffolds in minimal protein adhesive environments. For this purpose, a hydrophilic star- shaped crosslinkable polymer was used and the coating conditions were optimized. Moreover, newly developed photosensitive scaffolds facilitated a time and pH independent biofunctionalization.
Bioprintable hydrogels for biofabrication were based on the allyl-functionalization of gelatin (GelAGE) and modified hyaluronic acid-products, to enable hydrogel crosslinking by means of the thiol-ene click chemistry. Optimization of GelAGE hydrogel properties was achieved through an in-depth analysis of the synthesis parameters, varying Ene:SH ratios, different crosslinking molecules and photoinitiators. Homogeneity of thiol-ene crosslinked networks was compared to free radical polymerized hydrogels and the applicability of GelAGE as bioink for extrusion-based bioprinting was investigated. Purely hyaluronic acid-based bioinks were hypothesized to maintain mechanical- and rheological properties, cell viabilities and the processability, upon further decreasing the overall hydrogel polymer and thiol content.
Hydrogel coatings: Highly structured PCL scaffolds were fabricated with MEW and subjected to coatings with six-armed star-shaped crosslinkable polymers (sP(EO-stat-PO)). Crosslinking results from the aqueous induced hydrolysis of reactive isocyanate groups (NCO) of sP(EO-stat-PO) and increased the surface hydrophilicity and provided a platform for biofunctionalizations in minimal protein adhesive environments. Not only the coating procedure was optimized with respect to sP(EO-stat-PO) concentrations and coating durations, instead scaffold pre-treatments were developed, which were fundamental to enhance the final hydrophilicity to completely avoid unspecific protein adsorption on sP(EO-stat-PO) coated scaffolds. The sP(EO-stat-PO) layer thickness of around 100 nm generally allows in vitro studies not only in dependence on the scaffold biofunctionalization but also on the scaffold architecture. The hydrogel coating extent was assessed via an indirect quantification of the NCO-hydrolysis products. Knowledge of NCO-hydrolysis kinetics enabled to achieve a balance of sufficiently coated scaffolds while maintaining the presence of NCO-groups that were exploited for subsequent biofunctionalizations. However, this time and pH dependent biofunctionalization was restricted to small biomolecules. In order to overcome this limitation and to couple high molecular weight biomolecules another reaction route was developed. This route was based on the photolysis of diazirine moieties and enabled a time and pH independent scaffold biofunctionalization with streptavidin and collagen type I. The fibril formation ability of collagen was used to obtain different collagen conformations on the scaffolds and a preliminary in vitro study demonstrated the applicability to investigate cell-material interactions.
The herein developed scaffolds could be applied to gain deeper insights into the fundamentals of cellular sensing. Especially the complexity by which cells sense e.g. collagen remain to be further elucidated. Therefore, different hierarchies of collagen-like conformations could be coupled to the scaffolds, e.g. gelatin or collagen-derived peptide sequences, and the activation of DDR receptors in dependence on the complexity of the coupled substances could be determined. Due to the strong streptavidin-biotin bond, streptavidin functionalized scaffolds could be applied as a versatile platform to allow immobilization of any biotinylated molecules.
Gelatin-based bioinks: First the GelAGE products were synthesized with respect to molecular weight distributions and amino acid composition integrity. A detailed study was conducted with varying molar ratios of reactants and synthesis durations and implied that gelatin degradation was most dominant for high alkaline synthesis conditions with long reaction times. Gelatin possesses multiple functionalizable groups and the predominant functionalization of amine groups was confirmed via different model substances and analyses. Polymer network homogeneity was proven for the GelAGE system compared to free radical polymerized hydrogels with GelMA. A detailed analysis of hydrogel compositions with varying functional group ratios and UV- or Vis-light photoinitiators was executed. The UV-initiator concentration is restricted due to cytotoxicity and potential cellular DNA damages upon UV-irradiation, whereas the more cytocompatible Vis- initiator system enabled mechanical stiffness tuning over a wide range by controlling the photoinitiator concentration at constant Ene:SH ratios and polymer weight percentages. Versatility of the GelAGE bioink for different AM techniques was proved by exploiting the thermo-gelling behavior of differently degraded GelAGE products for stereolithography and extrusion-based printing. Moreover, the viability of cell-laden GelAGE constructs was demonstrated for extrusion-based bioprinting. By applying different multifunctional thiol-macromolecular crosslinkers the mechanical and rheological properties improved concurrently to the processability. Importantly, lower thiol-crosslinker concentrations were required to yield superior mechanical strengths and physico-chemical properties of the hydrogels as compared to the small bis-thiol-crosslinker. Extrusion-based bioprinting with distinct encapsulated cells underlined the need for individual optimization of cell-laden hydrogel formulations.
Not only the viability of encapsulated cells in extrusion-based bioprinted constructs should be assessed, instead other parameters such as cell morphology or production of collagen or glycosaminoglycans should be considered as these represent some of the crucial prerequisites for cartilage Tissue Engineering applications. Moreover, these studies should be expanded to the stereolithographic approach and ultimately the versatility and cytocompatibility of formulations with macromolecular crosslinkers would be of interest. Macromolecular crosslinkers allowed reducing polymer weight percentages and amounts of thiol groups and are thus expected to contribute to increased cytocompatibility, especially in combination with the more cytocompatible Vis-initiator system, which remains to be elucidated.
Hyaluronic acid-based bioinks: Different molecular weight hyaluronic acid (HA) products were synthesized to bear ene- (HAPA) or thiol-functionalities (LHASH) to enable pure HA thiol-ene crosslinked hydrogels. Depending on the molecular weight of modified HA products, polymer weight percentages and Ene:SH ratios, a wide range of mechanical stiffness was covered. However, the manageability of high molecular weight HA (HHAPA) product solutions (HHAPA + LHASH) was restricted to 5.0 wt.-% as a consequence of the high viscosity. Based on the same HA thiol component (LHASH), hybrid hydrogels of HA with GelAGE were compared to pure HA hydrogels. Although the overall polymer weight percentage of HHAPA + LHASH hydrogels was significantly lowered compared to hybrid hydrogels (GelAGE + LHASH), similar mechanical and physico-chemical properties of pure HA hydrogels were determined with maintained Ene:SH ratios. Low viscous low molecular weight HA precursor solutions (LHAPA + LHASH) prevented the applicability for extrusion-based bioprinting, whereas the non-thermoresponsive HHAPA + LHASH system could be bioprinted with only one-fourth of the polymer content of hybrid formulations. The high viscous behavior of HHAPA + LHASH solutions, lower polymer weight percentages, decreased printing pressures and consequently declined shear stress during printing, were hypothesized to contribute to high cell viabilities in extrusion-based bioprinted constructs compared to the hybrid bioink.
The low molecular weight HA precursor formulation (LHAPA + LHASH) was not applicable for extrusion-based printing, but this system has potential for other AM techniques such as stereolithography. Similar to the GelAGE system a more detailed study on the functions of encapsulated cells would be useful to further develop this system. Moreover, the initiation with the Vis-initiator should be conducted.
The implantation of any foreign material into the body automatically starts an immune reaction that serves as the first, mandatory step to regenerate tissue. The course of this initial immune reaction decides on the fate of the implant: either the biomaterial will be integrated into the host tissue to subsequently fulfill its intended function (e.g., tissue regeneration), or it will be repelled by fibrous encapsulation that determines the implant failure. Especially neutrophils and macrophages play major roles during this inflammatory response and hence mainly decide on the biomaterial's fate. For clinically relevant tissue engineering approaches, biomaterials may be designed in shape and morphology as well as in their surface functionality to improve the healing outcome, but also to trigger stem cell responses during the subsequent tissue regeneration phase.
The main focus of this thesis was to unravel the influence of scaffold characteristics, including scaffold morphology and surface functionality, on primary human innate immune cells (neutrophils and macrophages) and human mesenchymal stromal cells (hMSCs) to assess their in vitro immune response and tissue regeneration capacity, respectively. The fiber-based constructs were produced either via melt electrowriting (MEW), when the precise control over scaffold morphology was required, or via solution electrospinning (ES), when the scaffold design could be neglected. All the fiber-based scaffolds used throughout this thesis were composed of the polymer poly(ε caprolactone) (PCL).
A novel strategy to model and alleviate the first direct cell contact of the immune system with a peptide-bioactived fibrous material was presented in chapter 3 by treating the material with human neutrophil elastase (HNE) to imitate the neutrophil attack. The main focus of this study was put on the effect of HNE towards an RGDS-based peptide that was immobilized on the surface of a fibrous material to improve subsequent L929 cell adhesion. The elastase efficiently degraded the peptide-functionality, as evidenced by a decreased L929 cell adhesion, since the peptide integrated a specific HNE-cleavage site (AAPV-motif). A sacrificial hydrogel coating based on primary oxidized hyaluronic acid (proxHA), which dissolved within a few days after the neutrophil attack, provided an optimal protection of the peptide-bioactivated fibrous mesh, i.e, the hydrogel alleviated the neutrophil attack and largely ensured the biomaterial's integrity. Thus, according to these results, a means to protect the biomaterial is required to overcome the neutrophil attack.
Chapter 4 was based on the advancement of melt electrowriting (MEW) to improve the printing resolution of MEW scaffolds in terms of minimal inter-fiber distances and a concomitant high stacking precision. Initially, to gain a better MEW understanding, the influence of several parameters, including spinneret diameter, applied pressure, and collector velocity on mechanical properties, crystallinity, fiber diameter and fiber surface morphology was analyzed. Afterward, innovative MEW designs (e.g., box-, triangle-, round , and wall-shaped scaffolds) have been established by pushing the printing parameters to their physical limits. Further, the inter-fiber distance within a standardized box-structured scaffold was successfully reduced to 40 µm, while simultaneously a high stacking precision was maintained. In collaboration with a co-worker of my department (Tina Tylek, who performed all cell-based experiments in this study), these novel MEW scaffolds have been proven to facilitate human monocyte-derived macrophage polarization towards the regenerative M2 type in an elongation-driven manner with a more pronounced effect with decreasing pore sizes.
Finally, a pro-adipogenic platform for hMSCs was developed in chapter 5 using MEW scaffolds with immobilized, complex ECM proteins (e.g., human decellularized adipose tissue (DAT), laminin (LN), and fibronectin (FN)) to test for the adipogenic differentiation potential in vitro. Within this thesis, a special short-term adipogenic induction regime enabled to more thoroughly assess the intrinsic pro-adipogenic capacity of the composite biomaterials and prevented any possible masking by the commonly used long-term application of adipogenic differentiation reagents. The scaffolds with incorporated DAT consistently showed the highest adipogenic outcome and hence provided an adipo-inductive microenvironment for hMSCs, which holds great promise for applications in soft tissue regeneration.
Future studies should combine all three addressed projects in a more in vivo-related manner, comprising a co-cultivation setup of neutrophils, macrophages, and MSCs. The MEW-scaffold, particularly due to its ability to combine surface functionality and adjustable morphology, has been proven to be a successful approach for wound healing and paves the way for subsequent tissue regeneration.
Biointerface engineering is a wide-spread strategy to improve the healing process and subsequent tissue integration of biomaterials. Especially the integration of specific peptides is one promising strategy to promote the regenerative capacity of implants and 3D scaffolds. In vivo, these tailored interfaces are, however, first confronted with the innate immune response. Neutrophils are cells with pronounced proteolytic potential and the first recruited immune cells at the implant site; nonetheless, they have so far been underappreciated in the design of biomaterial interfaces. Herein, an in vitro approach is introduced to model and analyze the neutrophil interaction with bioactivated materials at the example of nano-bioinspired electrospun surfaces that reveals the vulnerability of a given biointerface design to the contact with neutrophils. A sacrificial, transient hydrogel coating that demonstrates optimal protection for peptide-modified surfaces and thus alleviates the immediate cleavage by neutrophil elastase is further introduced.
Calcium phosphate cement (CPC) is a well-established bone replacement material in dentistry and orthopedics. CPC mimics the physicochemical properties of natural bone and therefore shows excellent in vivo behavior. However, due to their brittleness, the application of CPC implants is limited to non-load bearing areas. Generally, the fiber-reinforcement of ceramic materials enhances fracture resistance, but simultaneously reduces the strength of the composite. Combining strong C-fiber reinforcement with a hydroxyapatite to form a CPC with a chemical modification of the fiber surface allowed us to adjust the fiber–matrix interface and consequently the fracture behavior. Thus, we could demonstrate enhanced mechanical properties of CPC in terms of bending strength and work of fracture to a strain of 5% (WOF5). Hereby, the strength increased by a factor of four from 9.2 ± 1.7 to 38.4 ± 1.7 MPa. Simultaneously, the WOF5 increased from 0.02 ± 0.004 to 2.0 ± 0.6 kJ∙m−2, when utilizing an aqua regia/CaCl2 pretreatment. The cell proliferation and activity of MG63 osteoblast-like cells as biocompatibility markers were not affected by fiber addition nor by fiber treatment. CPC reinforced with chemically activated C-fibers is a promising bone replacement material for load-bearing applications.
Despite advances in cartilage repair strategies, treatment of focal chondral lesions remains an important challenge to prevent osteoarthritis. Articular cartilage is organized into several layers and lack of zonal organization of current grafts is held responsible for insufficient biomechanical and biochemical quality of repair-tissue. The aim was to develop a zonal approach for cartilage regeneration to determine whether the outcome can be improved compared to a non-zonal strategy. Hydrogel-filled polycaprolactone (PCL)-constructs with a chondrocyte-seeded upper-layer deemed to induce hyaline cartilage and a mesenchymal stromal cell (MSC)-containing bottom-layer deemed to induce calcified cartilage were compared to chondrocyte-based non-zonal grafts in a minipig model. Grafts showed comparable hardness at implantation and did not cause visible signs of inflammation. After 6 months, X-ray microtomography (µCT)-analysis revealed significant bone-loss in both treatment groups compared to empty controls. PCL-enforcement and some hydrogel-remnants were retained in all defects, but most implants were pressed into the subchondral bone. Despite important heterogeneities, both treatments reached a significantly lower modified O’Driscoll-score compared to empty controls. Thus, PCL may have induced bone-erosion during joint loading and misplacement of grafts in vivo precluding adequate permanent orientation of zones compared to surrounding native cartilage.
Mucin, a high molecular mass hydrophilic glycoprotein, is the main component of mucus that coats every wet epithelium in animals. It is thus intrinsically biocompatible, and with its protein backbone and the o-glycosidic bound oligosaccharides, it contains a plethora of functional groups which can be used for further chemical modifications. Here, chain-growth and step-growth (thiol-ene) free-radical cross-linked hydrogels prepared from commercially available pig gastric mucin (PGM) are introduced and compared as cost-efficient and easily accessible alternative to the more broadly applied bovine submaxillary gland mucin. For this, PGM is functionalized with photoreactive acrylate groups or allyl ether moieties, respectively. Whereas homopolymerization of acrylate-functionalized polymers is performed, for thiol-ene cross-linking, the allyl-ether-functionalized PGM is cross-linked with thiol-functionalized hyaluronic acid. Morphology, mechanical properties, and cell compatibility of both kinds of PGM hydrogels are characterized and compared. Furthermore, the biocompatibility of these hydrogels can be evaluated in cell culture experiments.
Der Einfluss von Laktobazillen auf Oberfläche und Eigenschaften von verschiedenen Nahtmaterialien
(2015)
Hintergrund: Nach oralchirurgischen Eingriffen empfiehlt der Operateur allgemein die Vermeidung von Milchprodukten in Hinblick auf eine bessere Heilung im Wundgebiet. Dies stützt sich u.a. auf die Annahme, dass Laktobazillen und ihre Stoffwechselprodukte (z.B. Milchsäure) Nahtmaterial angreifen können. Der Aufbau dieser Studie zielte darauf ab, diesen Sachverhalt in Frage zu stellen und Funktionsverluste bei Milchsäureexposition sowie Besieldungsverhalten der Bakterien zu charakterisieren.
Material und Methoden: Polyamid (PA), Polyester/Polyethylenterephtalat (PET), Polypropylen (PP), Polyvinylidenfluorid (PVDF), Seide, Polyglycolsäure (PGA bzw. PGACL), teilweise mit Polylactid (PLA), Polydioxanon (PDO) und Polytetrafluorethylen (PTFE) kamen zur Anwendung. Die Fäden wurden mit L.acidophilus (LAC) beimpft, inkubiert und anschließen im Tensiometer mit verschiedenen Knotenvarianten getestet. Für die Keimbesiedlung (CFU) wurden die Fäden beimpft, inkubiert und das Keimmaterial anschließend mit Ultraschall- Vortex- Verfahren vom Faden abgelöst und ausgezählt. Dieses Verfahren wurde durch REM- Aufnahmen zusätzlich bewertet.
Ergebnisse: Reißfestigkeiten waren stets im Rahmen der Herstellerangaben bzw. darüber zu verzeichnen. Alle resorbierbaren Fäden hatten höhere Ausgangsreißkräfte als die nichtresorbierbaren Produkte. Die Applikation eines Knotens minderte ausschlaggebend für alle Produkte die maximale Reißfestigkeit eines Materials. Die Knotenhaltbarkeiten konnten sich während der Liegezeit im sauren wässrigen Milieu verändern. Die für klinische Anwendungen besten Ergebnisse verzeichneten PA als nichtresorbierbare, monofiles PDO und polyfiles PGA/PLA + CHX als resorbierbare Vertreter. Eine erhöhte CFU-Zahl auf polyfilen Fäden im Vergleich zu monofilen Fäden wurde bestätigt. Seide (polyfil, nicht resorbierbar) hatte mit Abstand die höchsten CFU, gefolgt von PGACL (polyfil, resorbierbar). PVDF (monofil, nichtresorbierbar) hatte die niedrigsten CFU- Werte. Im Schnitt war die CFU-Zahl von PGA/PLA+CHX (polyfil, resorbierbar) ähnlich hoch wie die von monofilen Produkten.
Diskussion: Die Annahme, dass eine Kontamination mit LAC den Heilungserfolg beeinflussen kann, wurde im Hinblick auf Materialermüdung durch Säureexposition aus Stoffwechselprodukten des Bakteriums entkräftet. Die für klinische Anwendungen besten Ergebnisse verzeichneten PA als nichtresorbierbare, polyfiles PGA/PLA + CHX als resorbierbare Vertreter. Alle getesteten Produkte entsprachen trotz LAC- Einwirkungen den Herstellerangaben und haben somit die materiellen Voraussetzungen einer vorhersagbaren Nahthaltbarkeit erbracht.
Calcium phosphate cements (CPC) represent valuable synthetic bone grafts, as they are self-setting, biocompatible, osteoconductive and in their composition similar to the inorganic phase of human bone. Due to their long shelf-life, neutral setting and since water is sufficient for setting, hydroxyapatite (HA) forming cements are processed in different paste formulations. Those comprise dual setting, Ca2+ binding and premixed cement systems. With dual setting formulations, both dissolution and precipitation of the cement raw powder occur simultaneously to the polymerization of water-soluble monomers to form a hydrogel. Chelating agents are able to form complexes with Ca2+ released from the raw powder. Premixed systems mostly contain the raw powder of the cement and a non-aqueous binder liquid which delays the setting reaction until application in the moist physiological environment. In the present work, two of those reaction mechanisms allowed the development of HA based cement applications.
Drillable cements are of high clinical interest, as the quality of screw and plate osteosynthesis techniques can be improved by cement augmentation. A drillable, dual setting composite from HA and a poly(2-hydroxyethyl methacrylate) hydrogel was analyzed with respect to the influence of monomer content and powder-to-liquid ratio on setting kinetics and mechanical outcome. While the conversion to HA and crystal growth were constantly confined with increased monomer amount, a minimum concentration of 50 % was required to see impressive ameliorations including a low bending modulus and high fracture energy at improved bending strength. Increasing the liquid amount enabled injection of the paste as well as drilling after 10 min of pre-setting.
While classic bone wax formulations have drawbacks such as infection, inflammation, hindered osteogenesis and a lack of biodegradability, the as-presented premixed formulation is believed to exhibit outmatching properties. It consisted of HA raw powders and a non-aqueous, but water-miscible carrier liquid from poly(ethylene glycol) (PEG). The bone wax was proved to be cohesive and malleable, it withstood blood pressure conditions and among deposition in an aqueous environment, PEG was exchanged such that porous, nanocrystalline HA was formed. Incorporation of a model antibiotic proved the suitability of the novel bone wax formulation for drug release purposes.
Prefabricated laminates from premixed carbonated apatite forming cement and poly(ε-caprolactone) fiber mats with defined pore architecture were presented as a potential approach for the treatment of 2-dimensional, curved cranial defects. They are flexible until application and were produced in a layer-by-layer approach from both components such that the polymer scaffold prevents the cement from flowing. It was demonstrated that solution electrospinning with a patterned collector for the fabrication of perforated fiber mats was suitable, as high fiber volume contents in combination with an appropriate interface enabled the successful fabrication of mechanically reinforced laminates. Mild immersion of the scaffolds under alkaline conditions additionally improved the interphase followed by an increase in bending-strength.
Since few years, magnesium phosphate cements (MPC) have attracted increasing attention for bone replacement. Compared to CPC, MPC exhibit a higher degradation potential and high early strength and they release biologically valuable Mg2+. However, common systems offer some challenges while using them in non-classic cement formulations such as the need for foreign ion supply, the potential acidity of the reaction or the fast setting kinetics. Here, it was possible to develop a chelate-setting MPC paste with a broad spectrum of potential applications.
The general mechanism of the novel setting principle was tested in a proof-of-principle manner. The cement paste consisted of farringtonite with differently concentrated phytic acid solution for chelate formation with Mg2+ from the raw powder. Adjusting the phytic acid content and adding a magnesium oxide as setting regulator to compensate its retarding effect resulted in drillable formulations. Additionally, there is a strong clinical demand for well working bone adhesives especially in a moist environment. Mostly the existing formulations are non-biodegradable. Ex vivo adhesion of the above presented MPC under wet conditions on bone demonstrated over a course of 7 d shear strengths of 0.8 MPa. Further, the hardened cement specimens showed a mass loss of 2 wt.% within 24 d in an aqueous environment and released about 0.17 mg/g of osteogenic Mg2+ per day. Together with the demonstrated cytocompatibility towards human fetal osteoblasts, this cement system showed promising characteristics in terms of degradable biocements with special application purposes.
Mineral bone cements were actually not developed for their application as bone-bonding agents, but as bone void fillers. In particular, calcium phosphate cements (CPC) are considered to be unsuitable for that application, particularly under moist conditions. Here, we showed the ex vivo ability of different magnesium phosphate cements (MPC) to adhere on bovine cortical bone substrates. The cements were obtained from a mixture of farringtonite (Mg\(_3\)(PO\(_4\))\(_2\)) with different amounts of phytic acid (C\(_6\)H\(_{18}\)O\(_{24}\)P\(_6\), inositol hexaphosphate, IP6), whereas cement setting occurred by a chelation reaction between Mg\(^{2+}\) ions and IP6. We were able to show that cements with 25% IP6 and a powder-to-liquid ratio (PLR) of 2.0 g/mL resulted in shear strengths of 0.81 ± 0.12 MPa on bone even after 7 d storage in aqueous conditions. The samples showed a mixed adhesive–cohesive failure with cement residues on the bone surface as indicated by scanning electron microscopy and energy-dispersive X-ray analysis. The presented material demonstrated appropriate bonding characteristics, which could enable a broadening of the mineral bone cements’ application field to bone adhesives
The focus of this thesis was to investigate how PCL and PLGA react to the heat exposure that comes with the MEW process over a defined timespan.
To assess the thermal stability of PCL during MEW over 25 d, an automated collection of fibers has been used to determine the CTS on each day of heating for three different temperatures. PCL is exceptionally stable over 25 d at 75 °C, whereas for 85 °C and 95 °C a slight upward trend during the last 10 d could be observed, which is an indication for thermal degradation. Same trend could be observed for diameter of fibers produced at a fixed collector speed. For all temperatures, CTS during the first 5 d decreased due to inhomogeneities of the melt. Physical analysis of the fibers by XRD and mechanical testing showed no significant changes.
To investigate the chemical details of the thermal durability, PCL was artificially aged over 25 d at 75 °C, 85 °C and 95 °C. Data from GPC analysis and rheology revealed that PCL is degrading steadily at all three temperatures. Combined with GC-MS analysis, two different mechanisms for degradation could be observed: random chain scission and unzipping. Additional GPC experiment using a mixture of PCL and a fluorescence labelled PCL showed that PCL was undergoing ester interchange reactions, which could explain its thermal stability.
PLGA was established successfully as material for MEW. GPC results revealed that PLGA degraded heavily in the one-hour preheating period. To reduce the processing temperature, ATEC was blended with PLGA in three mixtures. This slowed down degradation and a processing window of 6 h could be established. Mechanical testing with fibers produced with PLGA and all three blends was performed. PLGA was very brittle, whereas the blends showed an elastic behavior. This could be explained by ester interchange reactions that formed a loosely crosslinked network with ATEC.
The Multiweek Thermal Stability of Medical-Grade Poly(ε-caprolactone) During Melt Electrowriting
(2022)
Melt electrowriting (MEW) is a high-resolution additive manufacturing technology that places unique constraints on the processing of thermally degradable polymers. With a single nozzle, MEW operates at low throughput and in this study, medical-grade poly(ε-caprolactone) (PCL) is heated for 25 d at three different temperatures (75, 85, and 95 °C), collecting daily samples. There is an initial increase in the fiber diameter and decrease in the jet speed over the first 5 d, then the MEW process remains stable for the 75 and 85 °C groups. When the collector speed is fixed to a value at least 10% above the jet speed, the diameter remains constant for 25 d at 75 °C and only increases with time for 85 and 95 °C. Fiber fusion at increased layer height is observed for 85 and 95 °C, while the surface morphology of single fibers remain similar for all temperatures. The properties of the prints are assessed with no observable changes in the degree of crystallinity or the Young's modulus, while the yield strength decreases in later phases only for 95 °C. After the initial 5-d period, the MEW processing of PCL at 75 °C is extraordinarily stable with overall fiber diameters averaging 13.5 ± 1.0 µm over the entire 25-d period.
Polymers sensitive to thermal degradation include poly(lactic-co-glycolic acid) (PLGA), which is not yet processed via melt electrowriting (MEW). After an initial period of instability where mean fiber diameters increase from 20.56 to 27.37 µm in 3.5 h, processing stabilizes through to 24 h. The jet speed, determined using critical translation speed measurements, also reduces slightly in this 3.5 h period from 500 to 433 mm min\(^{−1}\) but generally remains constant. Acetyl triethyl citrate (ATEC) as an additive decreases the glass transition temperature of PLGA from 49 to 4 °C, and the printed ATEC/PLGA fibers exhibits elastomeric behavior upon handling. Fiber bundles tested in cyclic mechanical testing display increased elasticity with increasing ATEC concentration. The processing temperature of PLGA also reduces from 165 to 143 °C with increase in ATEC concentration. This initial window of unstable direct writing seen with neat PLGA can also be impacted through the addition of 10-wt% ATEC, producing fiber diameters of 14.13 ± 1.69 µm for the first 3.5 h of heating. The investigation shows that the initial changes to the PLGA direct-writing outcomes seen in the first 3.5 h are temporary and that longer times result in a more stable MEW process.
Das Ziel dieser Arbeit war es, die Modifizierung von porösem, calciumdefizitärem, nanokristallinem Hydroxylapatit mit verschiedenen Metallionen zu testen. Es wurden α‑TCP‑basierende Zementproben hergestellt, die durch zwei verschiedene Dotierungsmethoden mit bestimmten Metallionen (Cu2+, Co2+, Mn2+, Ni2+, V3+, Zn2+) modifiziert wurden. Die eine Methode bestand in der Zusinterung der entsprechenden Metallionen zum α‑TCP‑Pulver. Bei der anderen Methode waren die Ionen in unterschiedlicher Konzentration (1 mmolar, 100 μmolar, 10 μmolar) in der Binderlösung enthalten. Die hergestellten Zementproben wurden hinsichtlich bestimmter Eigenschaften wie der initialen Abbindezeit und Druckfestigkeit untersucht und zusätzlich rasterelektronenmikroskopischen, röntgen-diffraktometrischen und massenspektrometrischen Analysen unterzogen. Als Referenz diente ein bereits am Menschen erfolgreich als Knochenersatzmaterial eingesetzter nanokristalliner, calciumarmer Hydroxylapatit-Zement. Da Hydroxylapatit nahezu nur durch Osteoklasten mittels einer lokalen pH‑Wert-Absenkung resorbiert werden kann, wurden in‑vitro‑Versuche mit einer immortalisierten Makrophagen-Zelllinie durchgeführt. Über einen 15‑tägigen Versuchszeitraum wurde die Zytokompatibilität mittels bestimmter Zellproliferations- und Zellaktivitätsmessungen überprüft. Zusätzlich wurden die mit Zellen besiedelten Proben unter dem Rasterelektronenmikroskop betrachtet und eine TRAP‑Färbung durchgeführt, um die Differenzierung zu osteoklastenähnlichen Zellen beurteilen zu können.
Bei der Auswertung der Versuche wurde deutlich, dass nicht das Metall alleine maßgeblich für Veränderungen der physikalischen Eigenschaften im Vergleich zum metallfreien Referenzzement war. Auch die Art der Metallionendotierung, ob durch Zugabe mit der Binderlösung oder durch Zusinterung, hatte bei den Metallen unterschiedliche Auswirkungen auf die Zementeigenschaften. Während der Versuche wurden Abbindezeiten von 18 Minuten bis über 60 Minuten gemessen und Druckfestigkeiten zwischen 9,3 MPa und 30,5 MPa festgestellt. Bei der Auswertung der Zellversuchsreihe wurde festgestellt, dass die Zellen auf den mit Metallionen modifizierten Zementplättchen tendenziell eine niedrigere Aktivität bei gleich bleibender Proliferation aufwiesen als auf den metallfreien Referenzproben. Dieses Ergebnis konnte mikroskopisch bestätigt werden.
Reinforcing hydrogels with micro-fibre scaffolds obtained by a Melt-Electrospinning Writing (MEW) process has demonstrated great promise for developing tissue engineered (TE) constructs with mechanical properties compatible to native tissues. However, the mechanical performance and reinforcement mechanism of the micro-fibre reinforced hydrogels is not yet fully understood. In this study, FE models, implementing material properties measured experimentally, were used to explore the reinforcement mechanism of fibre-hydrogel composites. First, a continuum FE model based on idealized scaffold geometry was used to capture reinforcement effects related to the suppression of lateral gel expansion by the scaffold, while a second micro-FE model based on micro-CT images of the real construct geometry during compaction captured the effects of load transfer through the scaffold interconnections. Results demonstrate that the reinforcement mechanism at higher scaffold volume fractions was dominated by the load carrying-ability of the fibre scaffold interconnections, which was much higher than expected based on testing scaffolds alone because the hydrogel provides resistance against buckling of the scaffold. We propose that the theoretical understanding presented in this work will assist the design of more effective composite constructs with potential applications in a wide range of TE conditions.
In kürzlich erschienenen Studien hat sich die Zementformulierung Baghdadit (Ca3ZrSi2O9) durch Eigenschaften wie eine hydraulische Aktivität, Röntgenopazität und bioaktive Wirkung als potenzielles Material für die endodontische Anwendung qualifiziert. Ziel dieser Studie war es, Baghdadit als einphasigen Biozement und in Form verschiedener Materialzusammensetzungen auf vorteilhafte Eigenschaften im Hinblick auf die Anwendung als endodontischen Funktionswerkstoff zu untersuchen. Nach eigenständiger Herstellung des mechanisch aktivierten Zementpulvers Ca3ZrSi2O9, erfolgte die Charakterisierung der verschiedenen Zementformulierungen maBag, Bag100Bru und Bag50Bru hinsichtlich der Injizierbarkeit, des pH-Verlaufs während der Abbindung, der Druckfestigkeit und Phasenzusammensetzung mittels XRD. Daneben wurde Baghdadit zu je drei verschiedenen Gewichtsanteilen als Füllstoff in eine Methacrylat-basierte Matrix integriert und hinsichtlich der Fließfähigkeit entsprechend der Norm DIN EN ISO 6876:2012, des qualitativen Polymerisationsgrads und der Druckfestigkeit geprüft. Mit einer Auswahl der oben genannten Materialien erfolgte die Untersuchung der antibakteriellen Wirksamkeit, der Röntgensichtbarkeit orientierend an der Norm DIN EN ISO 13116:2014 und der Dichtigkeit im Wurzelkanal.
Combining multi-scale 3D printing technologies to engineer reinforced hydrogel-ceramic interfaces
(2020)
Multi-material 3D printing technologies that resolve features at different lengths down to the microscale open new avenues for regenerative medicine, particularly in the engineering of tissue interfaces. Herein, extrusion printing of a bone-biomimetic ceramic ink and melt electrowriting (MEW) of spatially organized polymeric microfibres are integrated for the biofabrication of an osteochondral plug, with a mechanically reinforced bone-to-cartilage interface. A printable physiological temperature-setting bioceramic, based on α-tricalcium phosphate, nanohydroxyapatite and a custom-synthesized biodegradable and crosslinkable poloxamer, was developed as bone support. The mild setting reaction of the bone ink enabled us to print directly within melt electrowritten polycaprolactone meshes, preserving their micro-architecture. Ceramic-integrated MEW meshes protruded into the cartilage region of the composite plug, and were embedded with mechanically soft gelatin-based hydrogels, laden with articular cartilage chondroprogenitor cells. Such interlocking design enhanced the hydrogel-to-ceramic adhesion strength >6.5-fold, compared with non-interlocking fibre architectures, enabling structural stability during handling and surgical implantation in osteochondral defects ex vivo. Furthermore, the MEW meshes endowed the chondral compartment with compressive properties approaching those of native cartilage (20-fold reinforcement versus pristine hydrogel). The osteal and chondral compartment supported osteogenesis and cartilage matrix deposition in vitro, and the neo-synthesized cartilage matrix further contributed to the mechanical reinforcement at the ceramic-hydrogel interface. This multi-material, multi-scale 3D printing approach provides a promising strategy for engineering advanced composite constructs for the regeneration of musculoskeletal and connective tissue interfaces.
Post-fabrication formation of a proper vasculature remains an unresolved challenge in bioprinting. Established strategies focus on the supply of the fabricated structure with nutrients and oxygen and either rely on the mere formation of a channel system using fugitive inks or additionally use mature endothelial cells and/or peri-endothelial cells such as smooth muscle cells for the formation of blood vessels in vitro. Functional vessels, however, exhibit a hierarchical organization and multilayered wall structure that is important for their function. Human induced pluripotent stem cell-derived mesodermal progenitor cells (hiMPCs) have been shown to possess the capacity to form blood vessels in vitro, but have so far not been assessed for their applicability in bioprinting processes. Here, we demonstrate that hiMPCs, after formulation into an alginate/collagen type I bioink and subsequent extrusion, retain their ability to give rise to the formation of complex vessels that display a hierarchical network in a process that mimics the embryonic steps of vessel formation during vasculogenesis. Histological evaluations at different time points of extrusion revealed the initial formation of spheres, followed by lumen formation and further structural maturation as evidenced by building a multilayered vessel wall and a vascular network. These findings are supported by immunostainings for endothelial and peri-endothelial cell markers as well as electron microscopic analyses at the ultrastructural level. Moreover, endothelial cells in capillary-like vessel structures deposited a basement membrane-like matrix at the basal side between the vessel wall and the alginate-collagen matrix. After transplantation of the printed constructs into the chicken chorioallantoic membrane (CAM) the printed vessels connected to the CAM blood vessels and get perfused in vivo. These results evidence the applicability and great potential of hiMPCs for the bioprinting of vascular structures mimicking the basic morphogenetic steps of de novo vessel formation during embryogenesis.
Evolution has endowed the lung with exceptional design providing a large surface area for gas exchange area (ca. 100 m\(^{2}\)) in a relatively small tissue volume (ca. 6 L). This is possible due to a complex tissue architecture that has resulted in one of the most challenging organs to be recreated in the lab. The need for realistic and robust in vitro lung models becomes even more evident as causal therapies, especially for chronic respiratory diseases, are lacking. Here, we describe the Cyclic In VItro Cell-stretch (CIVIC) “breathing” lung bioreactor for pulmonary epithelial cells at the air-liquid interface (ALI) experiencing cyclic stretch while monitoring stretch-related parameters (amplitude, frequency, and membrane elastic modulus) under real-time conditions. The previously described biomimetic copolymeric BETA membrane (5 μm thick, bioactive, porous, and elastic) was attempted to be improved for even more biomimetic permeability, elasticity (elastic modulus and stretchability), and bioactivity by changing its chemical composition. This biphasic membrane supports both the initial formation of a tight monolayer of pulmonary epithelial cells (A549 and 16HBE14o\(^{-}\)) under submerged conditions and the subsequent cell-stretch experiments at the ALI without preconditioning of the membrane. The newly manufactured versions of the BETA membrane did not improve the characteristics of the previously determined optimum BETA membrane (9.35% PCL and 6.34% gelatin [w/v solvent]). Hence, the optimum BETA membrane was used to investigate quantitatively the role of physiologic cyclic mechanical stretch (10% linear stretch; 0.33 Hz: light exercise conditions) on size-dependent cellular uptake and transepithelial transport of nanoparticles (100 nm) and microparticles (1,000 nm) for alveolar epithelial cells (A549) under ALI conditions. Our results show that physiologic stretch enhances cellular uptake of 100 nm nanoparticles across the epithelial cell barrier, but the barrier becomes permeable for both nano- and micron-sized particles (100 and 1,000 nm). This suggests that currently used static in vitro assays may underestimate cellular uptake and transbarrier transport of nanoparticles in the lung.
Chronic respiratory diseases are among the leading causes of death worldwide, but only symptomatic therapies are available for terminal illness. This in part reflects a lack of biomimetic in vitro models that can imitate the complex environment and physiology of the lung. Here, a copolymeric membrane consisting of poly(ε‐)caprolactone and gelatin with tunable properties, resembling the main characteristics of the alveolar basement membrane is introduced. The thin bioinspired membrane (≤5 μm) is stretchable (up to 25% linear strain) with appropriate surface wettability and porosity for culturing lung epithelial cells under air–liquid interface conditions. The unique biphasic concept of this membrane provides optimum characteristics for initial cell growth (phase I) and then switch to biomimetic properties for cyclic cell‐stretch experiments (phase II). It is showed that physiologic cyclic mechanical stretch improves formation of F‐actin cytoskeleton filaments and tight junctions while non‐physiologic over‐stretch induces cell apoptosis, activates inflammatory response (IL‐8), and impairs epithelial barrier integrity. It is also demonstrated that cyclic physiologic stretch can enhance the cellular uptake of nanoparticles. Since this membrane offers considerable advantages over currently used membranes, it may lead the way to more biomimetic in vitro models of the lung for translation of in vitro response studies into clinical outcome.
In vitro evaluation of antibacterial efficacy of vancomycin-loaded suture tapes and cerclage wires
(2021)
Usage of implants containing antibiotic agents has been a common strategy to prevent implant related infections in orthopedic surgery. Unfortunately, most implants with microbial repellent properties are characterized by accessibility limitations during daily clinical practice. Aim of this in vitro study was to investigate whether suture tapes and cerclage wires, which were treated with vancomycin, show a sustainable antibacterial activity. For this purpose, we used 24 stainless steel wire cerclages and 24 ultra-high molecular weight polyethylene and polyester suture tape test bodies. The test bodies were incubated for 30 min. in 100 mg/ml vancomycin solution or equivalent volumes of 0.9% NaCl. After measuring the initial solution uptake of the test bodies, antibacterial efficacy via agar diffusion test with Staphylococcus aureus and vancomycin elution tests were performed 1, 2, 3, and 6 days after incubation. Vancomycin-loaded tapes as well as vancomycin-loaded cerclage wires demonstrated increased bacterial growth inhibition when compared to NaCl-treated controls. Vancomycin-loaded tapes showed an additional twofold and eightfold increase of bacterial growth inhibition compared to vancomycin-loaded wires at day 1 and 2, respectively. Elution tests at day 1 revealed high levels of vancomycin concentration in vancomycin loaded tapes and wires. Additionally, the concentration in vancomycin loaded tapes was 14-fold higher when compared to vancomycin loaded wires. Incubating suture tapes and cerclage wires in vancomycin solution showed a good short-term antibacterial activity compared to controls. Considering the ease of vancomycin application on suture tapes or wires, our method could represent an attractive therapeutic strategy in biofilm prevention in orthopedic surgery.
Zinc (Zn2+) is considered as important mediator of immune cell function, thrombosis and haemostasis. However, our understanding of the transport mechanisms that regulate Zn2+ homeostasis in platelets is limited. Zn2+ transporters, ZIPs and ZnTs, are widely expressed in eukaryotic cells. Using mice globally lacking ZIP1 and ZIP3 (ZIP1/3 DKO), our aim was to explore the potential role of these Zn2+ transporters in maintaining platelet Zn2+ homeostasis and in the regulation of platelet function. While ICP-MS measurements indicated unaltered overall Zn2+ concentrations in platelets of ZIP1/3 DKO mice, we observed a significantly increased content of FluoZin3-stainable free Zn2+, which, however, appears to be released less efficiently upon thrombin-stimulated platelet activation. On the functional level, ZIP1/3 DKO platelets exhibited a hyperactive response towards threshold concentrations of G protein-coupled receptor (GPCR) agonists, while immunoreceptor tyrosine-based activation motif (ITAM)-coupled receptor agonist signalling was unaffected. This resulted in enhanced platelet aggregation towards thrombin, bigger thrombus volume under flow ex vivo and faster in vivo thrombus formation in ZIP1/3 DKO mice. Molecularly, augmented GPCR responses were accompanied by enhanced Ca2+ and PKC, CamKII and ERK1/2 signalling. The current study thereby identifies ZIP1 and ZIP3 as important regulators for the maintenance of platelet Zn2+ homeostasis and function.
The aim of this thesis was the development of a multifunctional coating system for AuNPs based on thioether polymers, providing both excellent colloidal stability and a variable possibility to introduce functionalities for biological applications.
First, two thioether-polymer systems were synthesised as a systematic investigation into colloidal stabilisation efficacy. Besides commonly used monovalent poly(ethylene glycol) (PEG-SR), its structural analogue linear poly(glycidol) (PG-SR) bearing multiple statistically distributed thioether moieties along the backbone was synthesised. Additionally, respective thiol analogues (PEG-SH and PG-SH) were produced and applied as reference.
Successive modification of varyingly large AuNPs with aforementioned thiol- and thioether-polymers was performed via ligand exchange reaction on citrate stabilised AuNPs. An increased stabilisation efficacy of both thioether-polymers against biological and physiological conditions, as well as against freeze-drying compared to thiol analogues was determined.
Based on the excellent colloidal stabilisation efficacy and multi-functionalisability of thioether-PG, a plethora of functional groups, such as charged groups, hydrophilic/hydrophobic chains, as well as bio-active moieties namely diazirine and biotin was introduced to the AuNP surface. Moreover, the generic and covalent binding of diazirine-modified PG-SR with biomolecules including peptides and proteins was thoroughly demonstrated.
Lastly, diverse applicability and bioactivity of aforementioned modified particles in various studies was displayed, once more verifying the introduction of functionalities. On the one hand the electrostatic interaction of charged AuNPs with hydrogels based on hyaluronic acid was applied to tune the release kinetics of particles from three-dimensional scaffolds. On the other hand the strong complexation of siRNA onto two positively charged AuNPs was proven. The amount of siRNA payload was tuneable by varying the surface charge, ionic strength of the surrounding medium and the N/P ratio. Moreover, the biological activity and selectivity of the biotin-streptavidin conjugation was verified with respectively functionalised particles in controlled agglomeration test and in laser-triggered cell elimination experiments. In the latter, streptavidin-functionalised AuNPs resulted in excellent depletion of biotinylated cells whereas unfunctionalised control particles failed, excluding unspecific binding of these particles to the cell surface.
In vorliegender Dissertationsarbeit wurde der Einfluss von MEW-gedruckten Scaffolds aus dem synthetischen Polymer PnPrOx, einem Poly(2-oxazolin), mit verschiedenen Oberflächenstrukturen (fibrillär, glatt) auf die Proteinexpression menschlicher Makrophagen untersucht. Dabei wurde überprüft, inwiefern die Beschaffenheit der Oberflächenstruktur des Polymers die Polarisierung von Makrophagen auf Proteinebene beeinflusst.
As a major component of the articular cartilage extracellular matrix, hyaluronic acid is a widely used biomaterial in regenerative medicine and tissue engineering. According to its well-known interaction with multiple chondrocyte surface receptors which positively affects many cellular pathways, some approaches by combining mesenchymal stem cells and hyaluronic acid-based hydrogels are already driven in the field of cartilage regeneration and fat tissue. Nevertheless, a still remaining major problem is the development of the ideal matrix for this purpose. To generate a hydrogel for the use as a matrix, hyaluronic acid must be chemically modified, either derivatized or crosslinked and the resulting hydrogel is mostly shaped by the mold it is casted in whereas the stem cells are embedded during or after the gelation procedure which does not allow for the generation of zonal hierarchies, cell density or material gradients. This thesis focuses on the synthesis of different hyaluronic acid derivatives and poly(ethylene glycol) crosslinkers and the development of different hydrogel and bioink compositions that allow for adjustment of the printability, integration of growth factors, but also for the material and biological hydrogel, respectively bioink properties.
Background
The spectrum of indications for the use of membranes and scaffolds in the field of oral and maxillofacial surgery includes, amongst others, guided bone regeneration (GBR). Currently available membrane systems face certain disadvantages such as difficult clinical handling, inconsistent degradation, undirected cell growth and a lack of stability that often complicate their application. Therefore, new membranes which can overcome these issues are of great interest in this field.
Methods
In this pilot study, we investigated polycaprolactone (PCL) scaffolds intended to enhance oral wound healing by means of melt electrospinning writing (MEW), which allowed for three-dimensional (3D) printing of micron scale fibers and very exact fiber placement. A singular set of box-shaped scaffolds of different sizes consisting of medical-grade PCL was examined and the scaffolds’ morphology was evaluated via scanning electron microscopy (SEM). Each prototype sample with box sizes of 225 μm, 300 μm, 375 μm, 450 μm and 500 μm was assessed for cytotoxicity and cell growth by seeding each scaffold with human osteoblast-like cell line MG63.
Results
All scaffolds demonstrated good cytocompatibility according to cell viability, protein concentration, and cell number. SEM analysis revealed an exact fiber placement of the MEW scaffolds and the growth of viable MG63 cells on them. For the examined box-shaped scaffolds with pore sizes between 225 μm and 500 μm, a preferred box size for initial osteoblast attachment could not be found.
Conclusions
These well-defined 3D scaffolds consisting of medical-grade materials optimized for cell attachment and cell growth hold the key to a promising new approach in GBR in oral and maxillofacial surgery.
Background
The role of cement-augmented screw fixation for calcaneal fracture treatment remains unclear. Therefore, this study was performed to biomechanically analyze screw osteosynthesis by reinforcement with either a calcium phosphate (CP)-based or polymethylmethacrylate (PMMA)-based injectable bone cement.
Methods
A calcaneal fracture (Sanders type IIA) including a central cancellous bone defect was generated in 27 synthetic bones, and the specimens were assigned to 3 groups. The first group was fixed with four screws (3.5 mm and 6.5 mm), the second group with screws and CP-based cement (Graftys (R) QuickSet; Graftys, Aix-en-Provence, France), and the third group with screws and PMMA-based cement (Traumacem (TM) V+; DePuy Synthes, Warsaw, IN, USA). Biomechanical testing was conducted to analyze peak-to-peak displacement, total displacement, and stiffness in following a standardized protocol.
Results
The peak-to-peak displacement under a 200-N load was not significantly different among the groups; however, peak-to-peak displacement under a 600- and 1000-N load as well as total displacement exhibited better stability in PMMA-augmented screw osteosynthesis compared to screw fixation without augmentation. The stiffness of the construct was increased by both CP- and PMMA-based cements.
Conclusion
Addition of an injectable bone cement to screw osteosynthesis is able to increase fixation strength in a biomechanical calcaneal fracture model with synthetic bones. In such cases, PMMA-based cements are more effective than CP-based cements because of their inherently higher compressive strength. However, whether this high strength is required in the clinical setting for early weight-bearing remains controversial, and the non-degradable properties of PMMA might cause difficulties during subsequent interventions in younger patients.
Actin cytoskeleton deregulation confers midostaurin resistance in FLT3-mutant acute myeloid leukemia
(2021)
The presence of FMS-like tyrosine kinase 3-internal tandem duplication (FLT3-ITD) is one of the most frequent mutations in acute myeloid leukemia (AML) and is associated with an unfavorable prognosis. FLT3 inhibitors, such as midostaurin, are used clinically but fail to entirely eradicate FLT3-ITD+AML. This study introduces a new perspective and highlights the impact of RAC1-dependent actin cytoskeleton remodeling on resistance to midostaurin in AML. RAC1 hyperactivation leads resistance via hyperphosphorylation of the positive regulator of actin polymerization N-WASP and antiapoptotic BCL-2. RAC1/N-WASP, through ARP2/3 complex activation, increases the number of actin filaments, cell stiffness and adhesion forces to mesenchymal stromal cells (MSCs) being identified as a biomarker of resistance. Midostaurin resistance can be overcome by a combination of midostaruin, the BCL-2 inhibitor venetoclax and the RAC1 inhibitor Eht1864 in midostaurin-resistant AML cell lines and primary samples, providing the first evidence of a potential new treatment approach to eradicate FLT3-ITD+AML. Garitano-Trojaola et al. used a combination of human acute myeloid leukemia (AML) cell lines and primary samples to show that RAC1-dependent actin cytoskeleton remodeling through BCL2 family plays a key role in resistance to the FLT3 inhibitor, Midostaurin in AML. They showed that by targeting RAC1 and BCL2, Midostaurin resistance was diminished, which potentially paves the way for an innovate treatment approach for FLT3 mutant AML.
Zelluläre Resorption 3D-gedruckter Knochenimplantate auf Basis von Calciummagnesiumphosphaten
(2023)
Für die Behandlung von Knochendefekten kritischer Größe gibt es heute eine Reihe von Therapiemöglichkeiten. Neuartige Ansätze mit Magnesiumphosphat- (MPC) und Calciummagnesiumphosphatzementen (CMPC) haben sich als echte Alternativen zu den etablierten Calciumphosphaten erwiesen.
Ziel war es, die Osteoklastogenese in vitro auf 3D-pulvergedrucktem CMPC und MPC zu induzieren und die zelluläre Resorption (zR) zu analysieren. Polystyrol (PS), Glas, β-TCP und Brushit-bildender Zement dienten als Referenzen.
Als Proben wurden Zemente der allgemeinen stöchiometrischen Summenformel CaxMg(3–x)(PO4)2 (x = 0; 0,25; 0,75; 3) verwendet, die Struvit oder Newberyit enthielten. Für die Osteoklastogenese wurden monozytenangereicherte PBMCs aus Buffy-Coat mittels dreifacher Dichtegradientenzentrifugation isoliert, auf die Prüfoberflächen ausgesät und über einen Zeitraum von 22 Tagen mit Zytokinen (M-CSF und RANKL) stimuliert. Die Interaktion der Zellen mit den Zementen bzw. PS/Glas wurde mittels TRAP-Färbung und -Aktivität, DNA- und Ionenkonzentrationen (Ca2+, Mg2+, PO43–, pH-Wert), Rasterelektronen-, Durchlicht-, Auflicht- und Fluoreszenzmikroskopie analysiert.
Auf den Struvit- und Newberyit-bildenden Zementen konnten keine für Osteoklasten typischen Riesenzellen nachgewiesen werden. Auf den Struvit-bildenden Zementen wurde deutlich mehr mononukleäre Zellen nachgewiesen wurden als auf den Newberyit-bildenden Zementen. Während die Freisetzung von Mg2+ und PO43– ausschließlich durch die chemische Degradation erfolgte, wurde Ca2+ zunächst adsorbiert und anschließend durch zR freigesetzt. Die erhöhte Ca2+-Adsorption im Vergleich zur Ca2+-Resorption führte insgesamt zu einer Calcium-Präzipitation.
Da lediglich auf β-TCP Resorptionslakunen beobachtet wurden, wird angenommen, dass auf den CMPC, MPC und Brushite-bildenden Zementen die zellvermittelte Ca2+-Freisetzung von den Präzipitaten ausging, die von Makrophagen auf den Zementen und/oder Riesenzellen auf den Wellplatten resorbiert wurden.
Calcium phosphate biocements based on calcium phosphate chemistry are well-established biomaterials for the repair of non-load bearing bone defects due to the brittle nature and low flexural strength of such cements. This article features reinforcement strategies of biocements based on various intrinsic or extrinsic material modifications to improve their strength and toughness. Altering particle size distribution in conjunction with using liquefiers reduces the amount of cement liquid necessary for cement paste preparation. This in turn decreases cement porosity and increases the mechanical performance, but does not change the brittle nature of the cements. The use of fibers may lead to a reinforcement of the matrix with a toughness increase of up to two orders of magnitude, but restricts at the same time cement injection for minimal invasive application techniques. A novel promising approach is the concept of dual-setting cements, in which a second hydrogel phase is simultaneously formed during setting, leading to more ductile cement-hydrogel composites with largely unaffected application properties.
Biofabrication aims to fabricate biologically functional products through bioprinting or bioassembly (Groll et al 2016 Biofabrication 8 013001). In biofabrication processes, cells are positioned at defined coordinates in three-dimensional space using automated and computer controlled techniques (Moroni et al 2018 Trends Biotechnol. 36 384–402), usually with the aid of biomaterials that are either (i) directly processed with the cells as suspensions/dispersions, (ii) deposited simultaneously in a separate printing process, or (iii) used as a transient support material. Materials that are suited for biofabrication are often referred to as bioinks and have become an important area of research within the field. In view of this special issue on bioinks, we aim herein to briefly summarize the historic evolution of this term within the field of biofabrication. Furthermore, we propose a simple but general definition of bioinks, and clarify its distinction from biomaterial inks.
Das Ziel der vorliegenden Arbeit war, die Gefrierstrukturierung von Biopolymer-Keramik-Kompositen zur Nachahmung von osteochondralem Gewebe zu untersuchen. Dies diente der Forschung an alternativen Therapiemethoden zur Regeneration von osteochondralen Defekten, da durch derzeitige Therapien oftmals nur ein minderwertiger Reparaturknorpel gebildet wird und keine langfristigen Erfolge erzielt werden. Die Herstellung der Proben zur Nachahmung von osteochondralem Gewebe erfolgte mit der Technik der Gefrierstrukturierung, wodurch anisotrope und hoch geordnete Systeme erhalten wurden. Im Rahmen einer systematischen Untersuchung wurden mehrere Parameter, wie beispielsweise der externe Temperaturgradient, variiert und deren Auswirkungen auf die Proben untersucht. Im ersten Versuchsteil wurde die bidirektionale Gefrierstrukturierung untersucht, um die Morphologie der hergestellten Proben zu optimieren. Anschließend wurden zweischichtige Alginat- bzw. Kollagen-Bruschit-Systeme zur Nachahmung von osteochondralem Gewebe hergestellt. Die erste Schicht sollte Knochen imitieren, während die zweite Schicht Knorpel nachahmte. Die Morphologie der hergestellten Proben wurde unter dem Stereo- und Rasterelektronenmikroskop untersucht. Zur Untersuchung des mechanischen Verbundes zwischen den Schichten wurden Zugversuche durchgeführt. Alle hergestellten Systeme waren hoch geordnet und anisotrop. Die zweischichtigen Systeme wiesen einen Verbund beider Schichten auf und durch die Variation verschiedenster Parameter konnte ein näheres Verständnis des Einflusses dieser auf die Probenmorphologie erlangt werden.
This study aimed to develop printable calcium magnesium phosphate pastes that harden by immersion in ammonium phosphate solution post-printing. Besides the main mineral compound, biocompatible ceramic, magnesium oxide and hydroxypropylmethylcellulose (HPMC) were the crucial components. Two pastes with different powder to liquid ratios of 1.35 g/mL and 1.93 g/mL were characterized regarding their rheological properties. Here, ageing over the course of 24 h showed an increase in viscosity and extrusion force, which was attributed to structural changes in HPMC as well as the formation of magnesium hydroxide by hydration of MgO. The pastes enabled printing of porous scaffolds with good dimensional stability and enabled a setting reaction to struvite when immersed in ammonium phosphate solution. Mechanical performance under compression was approx. 8–20 MPa as a monolithic structure and 1.6–3.0 MPa for printed macroporous scaffolds, depending on parameters such as powder to liquid ratio, ageing time, strand thickness and distance.
As one kind of “smart” material, thermogelling polymers find applications in biofabrication, drug delivery and regenerative medicine. In this work, we report a thermosensitive poly(2-oxazoline)/poly(2-oxazine) based diblock copolymer comprising thermosensitive/moderately hydrophobic poly(2-N-propyl-2-oxazine) (pPrOzi) and thermosensitive/moderately hydrophilic poly(2-ethyl-2-oxazoline) (pEtOx). Hydrogels were only formed when block length exceeded certain length (≈100 repeat units). The tube inversion and rheological tests showed that the material has then a reversible sol-gel transition above 25 wt.% concentration. Rheological tests further revealed a gel strength around 3 kPa, high shear thinning property and rapid shear recovery after stress, which are highly desirable properties for extrusion based three-dimensional (3D) (bio) printing. Attributed to the rheology profile, well resolved printability and high stackability (with added laponite) was also possible. (Cryo) scanning electron microscopy exhibited a highly porous, interconnected, 3D network. The sol-state at lower temperatures (in ice bath) facilitated the homogeneous distribution of (fluorescently labelled) human adipose derived stem cells (hADSCs) in the hydrogel matrix. Post-printing live/dead assays revealed that the hADSCs encapsulated within the hydrogel remained viable (≈97%). This thermoreversible and (bio) printable hydrogel demonstrated promising properties for use in tissue engineering applications.
Diese Arbeit befasst sich mit der Untersuchung von aus Patientenisolaten gewonnenen S. aureus Kulturen und deren Biofilmbildung auf implantatähnlichen Titan-Oberflächen. Ziel war es, den zeitlichen Ablauf bakterieller periprothetischer Infektionen über einen Zeitraum von 21 Tagen zu beschreiben und besser zu verstehen. Dazu sollte überprüft werden, ob ein fluoreszenzspektrometrisch ausgewertetes LIVE/DEAD Assay eine zusätzliche Aussage zum Status der im Biofilm befindlichen Zellen liefern kann. Zudem wurde die Biofilmentwicklung anhand etablierter fluoreszenzspektrometrischer Methoden (Concanavalin-A-Markierung extrazellulärer Polymerer Substanzen, DNA-Markierung mit Hoechst 33342) untersucht. Es konnte ein reproduzierbarer Verlauf der Entwicklung des Biofilms, sowie der DNA-Menge aufgezeigt werden. Das LIVE/DEAD Assay lieferte keine signifikanten Ergebnisse in Bezug auf das Verhältnis lebender zu toter S. aureus Zellen im Biofilm.
Weiter wurde die Angreifbarkeit des frühen, am Titan adhärenten Biofilms (Alter 1-5 Tage) durch das in der Orthopädie gängig eingesetzte Antibiotikum Gentamicin untersucht. Die Wirksamkeit konnte zu jedem getesteten Zeitpunkt der ersten fünf Tage durch Anzucht von Kolonien bestätigt werden. Auch wurde die Wirksamkeit über das LIVE/DEAD Assay überprüft, jedoch konnten hier keine aussagekräftigen Daten gewonnen werden, die diese Methode zur Überprüfung der Antibiotikawirksamkeit empfehlen könnten.
Hydrogele stehen als Material für den 3D-Biodruck zunehmend im Fokus aktueller Forschung, da sie aufgrund ihrer wasserhaltigen Struktur optimale Voraussetzungen für Anwendungen der Zellkultur aufweisen. Durch die Verarbeitung solcher Biotinten mittels additiver Fertigungstechniken der Biofabrikation erhofft man sich beschädigtes oder krankes Gewebe zu heilen oder zu ersetzen. Allerdings wird der Fortschritt in diesem Bereich durch einen Mangel an geeigneten Materialien gebremst, weshalb die Entwicklung neuer Biotinten von zentraler Bedeutung ist. Das Polymer GelAGE ist ein am Lehrstuhl für Funktionswerkstoffe der Medizin und Zahnheilkunde der Universität Würzburg synthetisiertes Hydrogelsystem. Zu diesem über eine Thiol-En Reaktion vernetzenden Material stehen systematische Untersuchungen der für die in vitro Zellkultur relevanten Eigenschaften noch aus. Das Ziel dieser Arbeit war daher die biologische Evaluation von GelAGE und der Vergleich mit der Biotinte Alginat-Gelatine.
Zu diesem Zweck wurden L929-Zellen für 7 Tage in verschiedenen Hydrogelzusammensetzungen in vitro kultiviert. Um die zytokompatiblen Eigenschaften in den verschiedenen Versuchsgruppen zu untersuchen, wurden die Proben mittels der in vitro Testverfahren Live/Dead Färbung, DNA-Assay, CCK-8-Assay und Phalloidin-Färbung analysiert.
Im Rahmen dieser Arbeit konnte ein Herstellungsprotokoll für das Material GelAGE etabliert werden, welches eine Grundlage für die Durchführung weiterer biologischer Experimente bietet. Das Resultat der biologischen Untersuchungen war, dass das Polymer GelAGE als zytokompatibel bewertet werden kann, es jedoch nicht die Qualität des Alginat-Gelatine Hydrogelsystems aufweist. Allerdings konnten die Eigenschaften der GelAGE Proben teilweise durch eine Modifikation mit Humanem Plättchenlysat verbessert werden. Des Weiteren konnten deutliche Unterschiede in der Zell-Material- Interaktion zwischen den verschiedenen GelAGE Varianten nachgewiesen werden.
In 3D bioprinting for cartilage regeneration, bioinks that support chondrogenic development are of key importance. Growth factors covalently bound in non-printable hydrogels have been shown to effectively promote chondrogenesis. However, studies that investigate the functionality of tethered growth factors within 3D printable bioinks are still lacking. Therefore, in this study, we established a dual-stage crosslinked hyaluronic acid-based bioink that enabled covalent tethering of transforming growth factor-beta 1 (TGF-β1). Bone marrow-derived mesenchymal stromal cells (MSCs) were cultured over three weeks in vitro, and chondrogenic differentiation of MSCs within bioink constructs with tethered TGF-β1 was markedly enhanced, as compared to constructs with non-covalently incorporated TGF-β1. This was substantiated with regard to early TGF-β1 signaling, chondrogenic gene expression, qualitative and quantitative ECM deposition and distribution, and resulting construct stiffness. Furthermore, it was successfully demonstrated, in a comparative analysis of cast and printed bioinks, that covalently tethered TGF-β1 maintained its functionality after 3D printing. Taken together, the presented ink composition enabled the generation of high-quality cartilaginous tissues without the need for continuous exogenous growth factor supply and, thus, bears great potential for future investigation towards cartilage regeneration. Furthermore, growth factor tethering within bioinks, potentially leading to superior tissue development, may also be explored for other biofabrication applications.
3D bioprinting often involves application of highly concentrated polymeric bioinks to enable fabrication of stable cell-hydrogel constructs, although poor cell survival, compromised stem cell differentiation, and an inhomogeneous distribution of newly produced extracellular matrix (ECM) are frequently observed. Therefore, this study presents a bioink platform using a new versatile dual-stage crosslinking approach based on thiolated hyaluronic acid (HA-SH), which not only provides stand-alone 3D printability but also facilitates effective chondrogenic differentiation of mesenchymal stromal cells. A range of HA-SH with different molecular weights is synthesized and crosslinked with acrylated (PEG-diacryl) and allylated (PEG-diallyl) polyethylene glycol in a two-step reaction scheme. The initial Michael addition is used to achieve ink printability, followed by UV-mediated thiol–ene reaction to stabilize the printed bioink for long-term cell culture. Bioinks with high molecular weight HA-SH (>200 kDa) require comparably low polymer content to facilitate bioprinting. This leads to superior quality of cartilaginous constructs which possess a coherent ECM and a strongly increased stiffness of long-term cultured constructs. The dual-stage system may serve as an example to design platforms using two independent crosslinking reactions at one functional group, which allows adjusting printability as well as material and biological properties of bioinks.
Many different biofabrication approaches as well as a variety of bioinks have been developed by researchers working in the field of tissue engineering. A main challenge for bioinks often remains the difficulty to achieve shape fidelity after printing. In order to overcome this issue, a homogeneous pre-crosslinking technique, which is universally applicable to all alginate-based materials, was developed. In this study, the Young’s Modulus after post-crosslinking of selected hydrogels, as well as the chemical characterization of alginate in terms of M/G ratio and molecular weight, were determined. With our technique it was possible to markedly enhance the printability of a 2% (w/v) alginate solution, without using a higher polymer content, fillers or support structures. 3D porous scaffolds with a height of around 5 mm were printed. Furthermore, the rheological behavior of different pre-crosslinking degrees was studied. Shear forces on cells as well as the flow profile of the bioink inside the printing nozzle during the process were estimated. A high cell viability of printed NIH/3T3 cells embedded in the novel bioink of more than 85% over a time period of two weeks could be observed.
This thesis concerned the design and examination of a scaffold for tissue engineering applications. The template for the presented scaffold came from nature itself: the intercellular space in tissues that provides structure and support to the cells of the respective tissue, known as extracellular matrix (ECM). Fibres are a predominant characteristic feature of ECM, providing adhesion sites for cell-matrix interactions. In this dissertation a fibrous mesh was generated using the electrospinning technique to mimic the fibrous structure of the ECM. Two base polymers were explored: a biodegradable polyester, poly(D,L-lactide-co-glycolide); and a functional PEG-based star polymer, NCO-sP(EO-stat-PO). This topic was described in three major parts: the first part was materials based, concerning the chemical design and characterisation of the polymer scaffolds; the focus was then shifted to the cellular response to this fibrous scaffold; and finally the in vivo performance of the material was preliminarily assessed. The first steps towards an electrospun mesh started with adjusting the spinning parameters for the generation of homogeneous fibres. As reported in Chapter 3 a suitable setup configuration was on the one hand comprised of a spinning solution that consisted of 28.5 w/v% PLGA RG 504 and 6 w/v% NCO-sP(EO-stat-PO) in 450 µL acetone, 50 µL DMSO and 10 µL of an aqueous trifluoroacetic acid solution. On the other hand an ideal spinning behaviour was achieved at process parameters such as a flow rate of 0.5 mL/h, spinneret to collector distance of 12-16 cm and a voltage of 13 kV. The NCO-sP(EO-stat-PO) containing fibres proved to be highly hydrophilic as the functional additive was present on the fibre surface. Furthermore, the fibres featured a bulk degradation pattern as a consequence of the proportion of PLGA. Besides the morphologic similarity to ECM fibres, the functionality of the electrospun fibres is also decisive for a successful ECM mimicry. In Chapter 4, the passive as well as active functionality of the fibres was investigated. The fibres were required to be protein repellent to prevent an unspecific cell adhesion. This was proven as even 6.5 % sP(EO-stat-PO) in the PLGA fibres reduced any unspecific protein adsorption of bovine serum albumin and foetal calf serum to less than 1 %. However, avidin based proteins attached to the fibres. This adhesion process was avoided by an additional fibre surface treatment with glycidol. The active functionalisation of NCO-sP(EO-stat-PO)/PLGA fibres was investigated with two fluorescent dyes and biocytin. A threefold, chemically orthogonal, fibre modification was achieved with these dyes. The chapters about the chemical and mechanical properties laid the basis for the in vitro chapters where a specific fibre functionalisation with peptides was conducted to analyse the cell adhesion and biochemical expressions. Beginning with fibroblasts in Chapter 5 the focus was on the specific cell adhesion on the electrospun fibres. While NCO-sP(EO-stat-PO)/PLGA fibres without peptides did not allow any adhesion of fibroblasts, a fibre modification with GRGDS (an adhesion mediating peptide sequence) induced the adhesion and spreading of human dermal fibroblasts on the fibrous scaffolds. The control sequence GRGES that has no adhesion mediating qualities did not lead to any cell adhesion as observed on fibres without modifications. While the experiments of Chapter 5 were a proof-of-concept, in Chapter 6 a possible application in cartilage tissue engineering was examined. Therefore, primary human chondrocytes were seeded on fibrous scaffolds with various peptide sequences. Though the chondrocytes exhibited high viability on all scaffolds, an active interaction of cells and fibres was only found for the decorin derived sequence CGKLER. Live-cell-imaging revealed both cell attachment and migration within CGKLER-modified meshes. As chondrocytes undergo a de-differentiation towards a fibroblast-like phenotype, the chondrogenic re-differentiation on these scaffolds was investigated in a long term cell culture experiment of 28 days. Therefore, the glycosaminoglycan production was analysed as well as the mRNA expression of genes coding for collagen I and II, aggrecan and proteoglycan 4. In general only low amounts of the chondrogenic markers were measured, suggesting no chondrogenic differentiation. For conclusive evidence follow-up experiments are required that support or reject the findings. The success of an implant for tissue engineering relies not only on the response of the targeted cell type but also on the immune reaction caused by leukocytes. Hence, Chapter 7 dealt with primary human macrophages and their behaviour and phenotype on two-dimensional (2D) surfaces compared to three-dimensional (3D) fibrous substrates. It was found that the general non-adhesiveness of NCO-sP(EO-stat-PO) surfaces and fibres does not apply to macrophages. The cells aligned along the fibres on surfaces or resided in the pores of the meshes. On flat surfaces without 3D structure the macrophages showed a retarded adhesion kinetic accompanied with a high migratory activity indicating their search for a topographical feature to adhere to. Moreover, a detailed investigation of cell surface markers and chemokine signalling revealed that macrophages on 2D surfaces exhibited surface markers indicating a healing phenotype while the chemokine release suggested a pro-inflammatory phenotype. Interestingly, the opposite situation was found on 3D fibrous substrates with pro-inflammatory surface markers and pro-angiogenic cytokine release. As the immune response largely depends on cellular communication, it was concluded that the NCO-sP(EO-stat-PO)/PLGA fibres induce an adequate immune response with promising prospects to be used in a scaffold for tissue engineering. The final chapter of this thesis reports on a first in vivo study conducted with the presented electrospun fibres. Here, the fibres were combined with a polypropylene mesh for the treatment of diaphragmatic hernias in a rabbit model. Two scaffold series were described that differed in the overall surface morphology: while the fibres of Series A were incorporated into a thick gel of NCO-sP(EO-stat-PO), the scaffolds of Series B featured only a thin hydrogel layer so that the overall fibrous structure could be retained. After four months in vivo the treated defects of the diaphragm were significantly smaller and filled mainly with scar tissue. Thick granulomas occurred on scaffolds of Series A while the implants of Series B did not induce any granuloma formation. As a consequence of the generally positive outcome of this study, the constructs were enhanced with a drug release system in a follow-up project. The incorporated drug was the MMP-inhibitor Ilomastat which is intended to reduce the formation of scar tissue. In conclusion, the simple and straight forward fabrication, the threefold functionalisation possibility and general versatile applicability makes the meshes of NCO-sP(EO-stat-PO)/PLGA fibres a promising candidate to be applied in tissue engineering scaffolds in the future.
Clinically used mineral bone cements lack high strength values, absorbability and drillability. Therefore, magnesium phosphate cements have recently received increasing attention as they unify a high mechanical performance with presumed degradation in vivo. To obtain a drillable cement formulation, farringtonite (Mg\(_3\)(PO\(_4\))\(_2\)) and magnesium oxide (MgO) were modified with the setting retardant phytic acid (C\(_6\)H\(_{18}\)O\(_{24}\)P\(_6\)). In a pre-testing series, 13 different compositions of magnesium phosphate cements were analyzed concentrating on the clinical demands for application. Of these 13 composites, two cement formulations with different phytic acid content (22.5 wt% and 25 wt%) were identified to meet clinical demands. Both formulations were evaluated in terms of setting time, injectability, compressive strength, screw pullout tests and biomechanical tests in a clinically relevant fracture model. The cements were used as bone filler of a metaphyseal bone defect alone, and in combination with screws drilled through the cement. Both formulations achieved a setting time of 5 min 30 s and an injectability of 100%. Compressive strength was shown to be ~12–13 MPa and the overall displacement of the reduced fracture was <2 mm with and without screws. Maximum load until reduced fracture failure was ~2600 N for the cements only and ~3800 N for the combination with screws. Two new compositions of magnesium phosphate cements revealed high strength in clinically relevant biomechanical test set-ups and add clinically desired characteristics to its strength such as injectability and drillability.
Tumorzellen, Stromazellen, Extrazellulärmatrix (EZM) und lösliche Faktoren in der Tumormikroumgebung beeinflussen und verstärken sich gegenseitig in der Ausbildung eines malignen Phänotyps. Sowohl die fibrotische EZM als auch eine kleine Subpopulation von pluripotenten Tumorstammzellen sind bekanntermaßen für die Steigerung der Tumoraggressivität verantwortlich. Inwiefern diese beiden unabhängigen Faktoren im Kontext von Brustkrebs miteinander in Beziehung stehen, ist jedoch bis heute unklar.
Um untersuchen zu können, welchen Beitrag Tumorzellen, Stromazellen, EZM und lösliche Faktoren einzeln und im Zusammenspiel zur Malignität eines Tumors leisten, ist die Entwicklung geeigneter in-vitro-Modelle unabdingbar. Daher war es das Ziel dieser Arbeit, ein 3D-Mikrotumormodell zu generieren, in dem eine Analyse dieser genannten Faktoren stattfinden könnte. An diesem Modell wurden darüber hinaus erste Untersuchungen von im Tumorkontext bekannten EZM-Proteinen durchgeführt. Um die dreidimensionale Anordnung von Tumorzellen und ihrer Gewebeumgebung adäquat wiedergeben zu können, beinhalteten die 3D-Tumorsphäroide sowohl Brustkrebszellen (MDA-MB-231) als auch Stromazellen (hASCs).
Die EZM als wichtiger Bestandteil der (Tumor-) Mikroumgebung sollte übersichtshalber durch Hämatoxylin-Eosin-Färbung und detaillierter durch immunhistochemische Analyse nach zwei verschiedenen Kulturzeitpunkten charakterisiert werden, um EZM-Veränderungen im zeitlichen Verlauf darzustellen. Im Fokus der Analyse standen die beiden wichtigsten profibrotischen EZM-Proteine Fibronektin und Kollagen I, die maßgeblich an der Pathogenese von Brustkrebs beteiligt sind. Zudem wurde das Vorkommen des Myofibroblastenmarkers α-SMA untersucht.
An den Sphäroiden einer Kontrollgruppe, die lediglich hASCs beinhaltete, sollte vergleichend eine Analyse der genannten EZM-Proteine sowie α-SMA durchgeführt werden. Um schließlich den Einfluss der von Tumorzellen sezernierten löslichen Faktoren in der Tumormikroumgebung herauszustellen, wurden Sphäroide aus hASCs in tumorkonditioniertem Medium gezüchtet und darin ebenfalls Matrixproteine und α-SMA untersucht.
Abschließend erfolgte eine Korrelation der EZM-Analyse mit dem Vorhandensein von Tumorstammzellen in den 3D-Tumorsphäroiden. Dafür wurden die Tumorstammzellen mithilfe eines GFP-basierten Reporters für den Stammzellmarker NANOG (NANOG-GFP-Reporterzelllinie) in mikroskopischen Aufnahmen der 3D-Tumorsphäroide nachgewiesen und im Kontext mit der EZM lokalisiert.
Bone graft substitutes in orthopedic applications have to fulfill various demanding requirements. Most calcium phosphate (CaP) bone graft substitutes are highly porous to achieve bone regeneration, but typically lack mechanical stability. This study presents a novel approach, in which a scaffold structure with appropriate properties for bone regeneration emerges from the space between specifically shaped granules. The granule types were tetrapods (TEPO) and pyramids (PYRA), which were compared to porous CaP granules (CALC) and morselized bone chips (BC). Bulk materials of the granules were mechanically loaded with a peak pressure of 4 MP; i.e., comparable to the load occurring behind an acetabular cup. Mechanical loading reduced the volume of CALC and BC considerably (89% and 85%, respectively), indicating a collapse of the macroporous structure. Volumes of TEPO and PYRA remained almost constant (94% and 98%, respectively). After loading, the porosity was highest for BC (46%), lowest for CALC (25%) and comparable for TEPO and PYRA (37%). The pore spaces of TEPO and PYRA were highly interconnected in a way that a virtual object with a diameter of 150 µm could access 34% of the TEPO volume and 36% of the PYRA volume. This study shows that a bulk of dense CaP granules in form of tetrapods and pyramids can create a scaffold structure with load capacities suitable for the regeneration of an acetabular bone defect
Synthetische anorganische Knochenersatzmaterialien auf Calcium-Phosphat- und Magnesium-Phosphat-Basis wurden in der hier vorliegenden Dissertation mit verschiedenen handelsüblichen Antibiotika versetzt und deren Freisetzungsverhalten charakterisiert. Zudem wurde der Einfluss des Antibiotikazusatzes auf bestimmte materialcharakteristische Eigenschaften untersucht, hierbei fanden die Quecksilberporosimetrie, die Röntgendiffraktometrie und die Rasterelektronenmikroskopie ihre Anwendung. Insbesondere für die Knochenersatzmaterialien auf Calcium-Phosphat-Basis sollte eine klinisch praktikable und demnach möglichst einfache Methode etabliert werden, um die Kombination mit einem Antibiotikum durchzuführen. Die Detektion der Antibiotika erfolgte mit Hilfe eines UV/VIS-Spektrophotometers. Zudem wurde für einige ausgewählte Kombinationen aus Antibiotikum und Knochenersatzmaterial durch einen Agardiffusionstest die antibakterielle Wirkung nach der Freisetzung aus dem jeweiligen Trägermaterial bestätigt.
In order to mimic the extracellular matrix for tissue engineering, recent research approaches often involve 3D printing or electrospinning of fibres to scaffolds as cell carrier material. Within this thesis, a micron fibre printing process, called melt electrospinning writing (MEW), combining both additive manufacturing and electrospinning, has been investigated and improved. Thus, a unique device was developed for accurate process control and manufacturing of high quality constructs. Thereby, different studies could be conducted in order to understand the electrohydrodynamic printing behaviour of different medically relevant thermoplastics as well as to characterise the influence of MEW on the resulting scaffold performance.
For reproducible scaffold printing, a commonly occurring processing instability was investigated and defined as pulsing, or in extreme cases as long beading. Here, processing analysis could be performed with the aim to overcome those instabilities and prevent the resulting manufacturing issues. Two different biocompatible polymers were utilised for this study: poly(ε-caprolactone) (PCL) as the only material available for MEW until then and poly(2-ethyl-2-oxazoline) for the first time. A hypothesis including the dependency of pulsing regarding involved mass flows regulated by the feeding pressure and the electrical field strength could be presented. Further, a guide via fibre diameter quantification was established to assess and accomplish high quality printing of scaffolds for subsequent research tasks.
By following a combined approach including small sized spinnerets, small flow rates and high field strengths, PCL fibres with submicron-sized fibre diameters (fØ = 817 ± 165 nm) were deposited to defined scaffolds. The resulting material characteristics could be investigated regarding molecular orientation and morphological aspects. Thereby, an alignment and isotropic crystallinity was observed that can be attributed to the distinct acceleration of the solidifying jet in the electrical field and by the collector uptake. Resulting submicron fibres formed accurate but mechanically sensitive structures requiring further preparation for a suitable use in cell biology. To overcome this handling issue, a coating procedure, by using hydrophilic and cross-linkable star-shaped molecules for preparing fibre adhesive but cell repellent collector surfaces, was used.
Printing PCL fibre patterns below the critical translation speed (CTS) revealed the opportunity to manufacture sinusoidal shaped fibres analogously to those observed using purely viscous fluids falling on a moving belt. No significant influence of the high voltage field during MEW processing could be observed on the buckling phenomenon. A study on the sinusoidal geometry revealed increasing peak-to-peak values and decreasing wavelengths as a function of decreasing collector speeds sc between CTS > sc ≥ 2/3 CTS independent of feeding pressures. Resulting scaffolds printed at 100 %, 90 %, 80 % and 70 % of CTS exhibited significantly different tensile properties, foremost regarding Young’s moduli (E = 42 ± 7 MPa to 173 ± 22 MPa at 1 – 3 % strain). As known from literature, a changed morphology and mechanical environment can impact cell performance substantially leading to a new opportunity of tailoring TE scaffolds.
Further, poly(L-lactide-co-ε-caprolactone-co-acryloyl carbonate) as well as poly(ε-caprolactone-co-acryloyl carbonate) (PCLAC) copolymers could be used for MEW printing. Those exhibit the opportunity for UV-initiated radical cross-linking in a post-processing step leading to significantly increased mechanical characteristics. Here, single fibres of the polymer composed of 90 mol.% CL and 10 mol.% AC showed a considerable maximum tensile strength of σmax = 53 ± 16 MPa. Furthermore, sinusoidal meanders made of PCLAC yielded a specific tensile stress-strain characteristic mimicking the qualitative behaviour of tendons or ligaments. Cell viability by L929 murine fibroblasts and live/dead staining with human mesenchymal stem cells revealed a promising biomaterial behaviour pointing out MEW printed PCLAC scaffolds as promising choice for medical repair of load-bearing soft tissue.
Indeed, one apparent drawback, the small throughput similar to other AM methods, may still prevent MEW’s industrial application yet. However, ongoing research focusses on enlargement of manufacturing speed with the clear perspective of relevant improvement. Thereby, the utilisation of large spinneret sizes may enable printing of high volume rates, while downsizing the resulting fibre diameter via electrical field and mechanical stretching by the collector uptake. Using this approach, limitations of FDM by small nozzle sizes could be overcome. Thinking visionary, such printing devices could be placed in hospitals for patient-specific printing-on-demand therapies one day. Taking the evolved high deposition precision combined with the unique small fibre diameter sizes into account, technical processing of high performance membranes, filters or functional surface finishes also stands to reason.
Additive manufacturing of scaffolds with sub-micron filaments via melt electrospinning writing
(2015)
The aim of this study was to explore the lower resolution limits of an electrohydrodynamic process combined with direct writing technology of polymer melts. Termed melt electrospinning writing, filaments are deposited layer-by-layer to produce discrete three-dimensional scaffolds for in vitro research. Through optimization of the parameters (flow rate, spinneret diameter, voltage, collector distance) for poly-ϵ-caprolactone, we could direct-write coherent scaffolds with ultrafine filaments, the smallest being 817 ± 165 nm. These low diameter filaments were deposited to form box-structures with a periodicity of 100.6 ± 5.1 μm and a height of 80 μm (50 stacked filaments; 100 overlap at intersections). We also observed oriented crystalline regions within such ultrafine filaments after annealing at 55 °C. The scaffolds were printed upon NCO-sP(EO-stat-PO)-coated glass slide surfaces and withstood frequent liquid exchanges with negligible scaffold detachment for at least 10 days in vitro.
Mineral biocements are brittle materials, which usually results in catastrophic failure during mechanical loading. Here, previous works demonstrated the feasibility of reducing brittleness by a dual-setting approach, in which a silica sol was simultaneously gelled during the setting of a brushite forming cement. The current thesis aimed at further improving this concept by both using a novel silicate based cement matrix for an enhanced bonding between cement and silica matrix as well as multifunctional silica precursors to increase the network density of the gel. Due to its well-known biocompatibility and osteogenic regeneration capacity, baghdadite was chosen as mineral component of such composites. This required in a first approach the conversion of baghdadite ceramics into self-setting cement formulations. This was investigated initially by using baghdadite as reactive filler in a brushite forming cement (Chapter 4). Here, the ß-TCP component in a equimolar mixture of ß-TCP and acidic monocalcium phosphate anhydrous was subsequently replaced by baghdadite at various concentrations (0, 5, 10, 20, 30, 50, and 100 wt%) to study the influence on physicochemical cement properties such as mechanical performance, radiopacity, phase composition and microstructure. X-ray diffraction profiles demonstrated the dissolution of baghdadite during the cement reaction without affecting the crystal structure of the precipitated brushite phase. In addition, EDX analysis showed that calcium is homogeneously distributed in the cement matrix, while zirconium and silicon form cluster-like aggregates ranging in size from a few micrometers to more than 50 µm. X-ray images and µ-CT analyses indicate improved X-ray visibility with increased incorporation of baghdadite in brushite cement, with an aluminum equivalent thickness nearly doubling at a baghdadite content of 50 wt%. At the same time, the compressive strength of brushite cement increased from 12.9 ± 3.1 MPa to 21.1 ± 4.1 MPa at a baghdadite content of 10 wt%. Cell culture medium conditioned with powdered brushite cement approached physiological pH values when increasing amounts of baghdadite were added to the cement (pH = 6.47 for pure brushite, pH = 7.02 for brushite with 20 wt% baghdadite substitution). Baghdadite substitution also affected the ion content in the culture medium and thus the proliferation activity of primary human osteoblasts in vitro. The results demonstrated for the first time the suitability of baghdadite as a reactive cement additive for improving the radiopacity, mechanical performance, and cytocompatibility of brushite cements.
A second approach (Chapter 5) aimed to produce single component baghdadite cements by an increase of baghdadite solubility to initiate a self-setting cement reaction. For this, the material was mechanically activated by longer grinding times of up to 24h leading to both a decrease in particle and crystallite size as well as a partial amorphization of baghdadite. Baghdadite cements were formed by adding water at a powder to liquid ratio of 2.0 g/ml. Maximum compressive strengths were determined to be ~2 MPa after 3 days of setting for a 24-hour ground material. Inductively coupled plasma mass spectrometry (ICP-MS) measurements showed an incongruent dissolution profile of the set cements, with preferential dissolution of calcium and only minor release of zirconium ions. Cement formation occurs under alkaline conditions, with the unground raw powder resulting in a pH of 11.9 during setting, while prolonged grinding increases the pH to about 12.3.
Finally, mechanically activated baghdadite cements were combined with inorganic silica networks (Chapter 6) to create dual-setting cements with a further improvement of mechanical performance. While a modification of the cement pastes with a TEOS derived sol was already thought to improve strength, it was hypothesized that using multi-arm silica precursors can further enhance their mechanical performance due to a higher network density. In addition, this should also reduce pore size of both gels and cement and hence will be able to adjust the release kinetics of incorporated drugs. For this, multi-armed silica precursors were synthesized by the reaction of various multivalent alcohols (ethylene glycol, glycerine, pentaerythrit) with an isocyanate modified silica precursor. After hydrolysis under acidic conditions, the sols were mixed with baghdadite cement powders in order to allow a simultaneous gel formation and cement setting. Since the silica monomers have a high degree of linkage sites, this resulted in a branched network that interpenetrated with the growing cement crystals. In addition to minor changes in the crystalline phase composition as determined by X-ray diffraction, the novel composites exhibited improved mechanical properties with up to 20 times higher compressive strength and further benefit from an about 50% lower overall porosity than the reference pure baghdadite cement. In addition, the initial burst release of the model drug vancomycin was completely inhibited by the added silica matrix. This observation was verified by testing for the antimicrobial activity with Staphylococcus aureus by measuring the inhibition zones of selected samples after 24 h and 48 h, whereas the antimicrobial effectiveness of a constant vancomycin release could be demonstrated.
The current thesis clearly demonstrated the high potential of baghdadite as a cement formulation for medical application. The initially poor mechanical properties of such cements can be overcome by special processing techniques or by combination with silica networks. The achieved mechanical performance is > 10 MPa and hence suitable for bone replacement under non-load bearing conditions. The high intrinsic radiopacity as well as the alkaline pH during setting may open the way ahead to further dental applications, e.g. as root canal sealers or filler in dental composites. Here, the high pH is thought to lead to antimicrobial properties of such materials similar to commonly applied calcium hydroxide or calcium silicates, however combined with an intrinsic radiopacity for X-ray imaging. This would simplify such formulations to single component materials which are less susceptible to demixing processes during transport, storage or processing.
In this study, the hydraulic reactivity and cement formation of baghdadite (Ca\(_{3}\)ZrSi\(_{2}\)O\(_{9}\)) was investigated. The material was synthesized by sintering a mixture of CaCO\(_{3}\), SiO\(_{2}\), and ZrO\(_{2}\) and then mechanically activated using a planetary mill. This leads to a decrease in particle and crystallite size and a partial amorphization of baghdadite as shown by X-ray powder diffraction (XRD) and laser diffraction measurements. Baghdadite cements were formed by the addition of water at a powder to liquid ratio of 2.0 g/ml. Maximum compressive strengths were found to be ~2 MPa after 3-day setting for a 24-h ground material. Inductively coupled plasma mass spectrometry (ICP-MS) measurements showed an incongruent dissolution profile of set cements with a preferred dissolution of calcium and only marginal release of zirconium ions. Cement formation occurs under alkaline conditions, whereas the unground raw powder leads to a pH of 11.9 during setting, while prolonged grinding increased pH values to approximately 12.3.
Biofabrication, including printing technologies, has emerged as a powerful approach to the design of disease models, such as in cancer research. In breast cancer, adipose tissue has been acknowledged as an important part of the tumor microenvironment favoring tumor progression. Therefore, in this study, a 3D-printed breast cancer model for facilitating investigations into cancer cell-adipocyte interaction was developed. First, we focused on the printability of human adipose-derived stromal cell (ASC) spheroids in an extrusion-based bioprinting setup and the adipogenic differentiation within printed spheroids into adipose microtissues. The printing process was optimized in terms of spheroid viability and homogeneous spheroid distribution in a hyaluronic acid-based bioink. Adipogenic differentiation after printing was demonstrated by lipid accumulation, expression of adipogenic marker genes, and an adipogenic ECM profile. Subsequently, a breast cancer cell (MDA-MB-231) compartment was printed onto the adipose tissue constructs. After nine days of co-culture, we observed a cancer cell-induced reduction of the lipid content and a remodeling of the ECM within the adipose tissues, with increased fibronectin, collagen I and collagen VI expression. Together, our data demonstrate that 3D-printed breast cancer-adipose tissue models can recapitulate important aspects of the complex cell–cell and cell–matrix interplay within the tumor-stroma microenvironment
Magnetic particle imaging is an emerging tomographic method used for evaluation of the spatial distribution of iron‐oxide nanoparticles. In this work, the effect of the polymer coating on the response of particles was studied. Particles with covalently crosslinked coating showed improved signal and image resolution.
This thesis aimed to evaluate the possibility to use nanoparticles as antifungal drug carriers as well as their potential application in screening and diagnostics of invasive aspergillosis. The interaction of nanogels, superparamagnetic iron oxide nanoparticles (SPIOs) and gold nanoparticles (GNP) with fungal-specific polysaccharides, cells and biofilms was investigated.
Firstly, it was evaluated how the charge of nanogels influence their interaction with fungal cells. Linear poly(glycidol)s (pG) and poly(2-methyl-2-oxazoline) (pMOx) polymers were synthesized and further functionalized with thiol groups for preparation of redox responsive nanogels. Results showed that negatively charged nanogels were internalized by the fungi to a much greater extent than positively charged ones.
Furthermore, it was investigated how amphiphilicity of polymers used for preparation of nanogels influences nanogel-fungi interaction. It was concluded that nanogels prepared from polymers with degree of functionalization of 10% had the strongest interaction, regardless the length of the alkyl chain. Moreover, amphotericin B-loaded nanogels had a higher antifungal effect and lower toxicity towards mammalian cells than the free drug. In addition, inverse nanoprecipitation of thiol functionalized pGs was shown to be successful for preparation of nanogels with narrow size distribution.
It was also demonstrated that crosslinking of the polymeric coating in hydrogel-like network with thiol functionalized pGs improved the SPIOs imaging performance.
Finally, it was investigated whether GNPs could be used as model particles for the assessment of targeting to fungi. Fc dectin-1 was conjugated covalently to GNPs decorated with pGs, and binding affinity towards β-glucans was tested by surface plasmon resonance.
In summary, this thesis demonstrated evidence for the potential of pG nanogels and pG coated nanoparticles for antifungal therapy and diagnostics of fungal infections caused by A. fumigatus.
In this study, well-defined, 3D arrays of air-suspended melt electrowritten fibers are made from medical grade poly(ɛ-caprolactone) (PCL). Low processing temperatures, lower voltages, lower ambient temperature, increased collector distance, and high collector speeds all aid to direct-write suspended fibers that can span gaps of several millimeters between support structures. Such processing parameters are quantitatively determined using a “wedge-design” melt electrowritten test frame to identify the conditions that increase the suspension probability of long-distance fibers. All the measured parameters impact the probability that a fiber is suspended over multimillimeter distances. The height of the suspended fibers can be controlled by a concurrently fabricated fiber wall and the 3D suspended PCL fiber arrays investigated with early post-natal mouse dorsal root ganglion explants. The resulting Schwann cell and neurite outgrowth extends substantial distances by 21 d, following the orientation of the suspended fibers and the supporting walls, often generating circular whorls of high density Schwann cells between the suspended fibers. This research provides a design perspective and the fundamental parametric basis for suspending individual melt electrowritten fibers into a form that facilitates cell culture.
As a promising biofabrication technology, extrusion-based bioprinting has gained significant attention in the last decade and major advances have been made in the development of bioinks. However, suitable synthetic and stimuli-responsive bioinks are underrepresented in this context. In this work, we described a hybrid system of nanoclay Laponite XLG and thermoresponsive block copolymer poly(2-methyl-2-oxazoline)-b-poly(2-n-propyl-2-oxazine) (PMeOx-b-PnPrOzi) as a novel biomaterial ink and discussed its critical properties relevant for extrusion-based bioprinting, including viscoelastic properties and printability. The hybrid hydrogel retains the thermogelling properties but is strengthened by the added clay (over 5 kPa of storage modulus and 240 Pa of yield stress). Importantly, the shear-thinning character is further enhanced, which, in combination with very rapid viscosity recovery (~ 1 s) and structure recovery (~ 10 s), is highly beneficial for extrusion-based 3D printing. Accordingly, various 3D patterns could be printed with markedly enhanced resolution and shape fidelity compared to the biomaterial ink without added clay.
Fibrous tissue growth and loss of residual hearing after cochlear implantation can be reduced by application of the glucocorticoid dexamethasone-21-phosphate-disodium-salt (DEX). To date, sustained delivery of this agent to the cochlea using a number of pharmaceutical technologies has not been entirely successful. In this study we examine a novel way of continuous local drug application into the inner ear using a refillable hydrogel functionalized silicone reservoir. A PEG-based hydrogel made of reactive NCO-sP(EO-stat-PO) prepolymers was evaluated as a drug conveying and delivery system in vitro and in vivo. Encapsulating the free form hydrogel into a silicone tube with a small opening for the drug diffusion resulted in delayed drug release but unaffected diffusion of DEX through the gel compared to the free form hydrogel. Additionally, controlled DEX release over several weeks could be demonstrated using the hydrogel filled reservoir. Using a guinea-pig cochlear trauma model the reservoir delivery of DEX significantly protected residual hearing and reduced fibrosis. As well as being used as a device in its own right or in combination with cochlear implants, the hydrogel-filled reservoir represents a new drug delivery system that feasibly could be replenished with therapeutic agents to provide sustained treatment of the inner ear.
3D neuronal cultures attempt to better replicate the in vivo environment to study neurological/neurodegenerative diseases compared to 2D models. A challenge to establish 3D neuron culture models is the low elastic modulus (30–500 Pa) of the native brain. Here, an ultra-soft matrix based on thiolated hyaluronic acid (HA-SH) reinforced with a microfiber frame is formulated and used. Hyaluronic acid represents an essential component of the brain extracellular matrix (ECM). Box-shaped frames with a microfiber spacing of 200 µm composed of 10-layers of poly(ɛ-caprolactone) (PCL) microfibers (9.7 ± 0.2 µm) made via melt electrowriting (MEW) are used to reinforce the HA-SH matrix which has an elastic modulus of 95 Pa. The neuronal viability is low in pure HA-SH matrix, however, when astrocytes are pre-seeded below this reinforced construct, they significantly support neuronal survival, network formation quantified by neurite length, and neuronal firing shown by Ca\(^{2+}\) imaging. The astrocyte-seeded HA-SH matrix is able to match the neuronal viability to the level of Matrigel, a gold standard matrix for neuronal culture for over two decades. Thus, this 3D MEW frame reinforced HA-SH composite with neurons and astrocytes constitutes a reliable and reproducible system to further study brain diseases.
Impairments in neuronal circuits underly multiple neurodevelopmental and neurodegenerative disorders. 3D cell culture models enhance the complexity of in vitro systems and provide a microenvironment closer to the native situation than with 2D cultures. Such novel model systems will allow the assessment of neuronal network formation and their dysfunction under disease conditions. Here, mouse cortical neurons are cultured from embryonic day E17 within in a fiber‐reinforced matrix. A soft Matrigel with a shear modulus of 31 ± 5.6 Pa is reinforced with scaffolds created by melt electrowriting, improving its mechanical properties and facilitating the handling. Cortical neurons display enhance cell viability and the neuronal network maturation in 3D, estimated by staining of dendrites and synapses over 21 days in vitro, is faster in 3D compared to 2D cultures. Using functional readouts with electrophysiological recordings, different firing patterns of action potentials are observed, which are absent in the presence of the sodium channel blocker, tetrodotoxin. Voltage‐gated sodium currents display a current–voltage relationship with a maximum peak current at −25 mV. With its high customizability in terms of scaffold reinforcement and soft matrix formulation, this approach represents a new tool to study neuronal networks in 3D under normal and, potentially, disease conditions.
Ziel dieser Arbeit war die Entwicklung und Charakterisierung vorgemischter Calciumphosphatzementpasten sowie die Übertragung des Konzepts dieser Pasten auf den 3D-Druck. Es wurden drei verschiedene Zementformulierungen untersucht, basierend auf Pulvermischungen aus α-TCP/DCPA/CaCO3 (Biozement D), TTCP/DCPA und β-TCP/MCPA, die auf verschiedene Materialeigenschaften geprüft und einem 3D-Druckversuch unterzogen wurden. Die Biozement D Paste wurde mit drei Pulver-Flüssigkeits-Verhältnissen (PLR) (80/20, 85/15, 87/13), die TTCP/DCPA Paste mit zwei PLR (83/17, 85/15), und die β-TCP/MCPA Paste ebenfalls mit zwei PLR (67/33, 70/30) getestet. Alle Pasten konnten mit dem 3D-Drucker erfolgreich verdruckt werden. Die Biozement D Paste mit dem PLR 85/15 stellte sich in ihrer Gruppe als die geeignetste Paste heraus. Bessere Ergebnisse bezüglich der Injizierbarkeit und Druckbarkeit erreichte die TTCP/DCPA Paste. Hier wurden mit beiden PLR formstabile Scaffolds erzielt. Feine Wabenmuster konnten mit dem PLR von 83/17 in Kombination mit einer hohen Druckgeschwindigkeit hergestellt werden. Mit dem höheren PLR (85/15) und einer niedrigeren Druckgeschwindigkeit stieg die Formstabilität weiter an, wodurch die hexagonale Struktur exakter gedruckt werden konnte. Ein gutes Druckergebnis konnte auch mit der β-TCP/MCPA Paste und dem PLR 70/30 erreicht werden.
To facilitate true regeneration, a vascular graft should direct the evolution of a neovessel to obtain the function of a native vessel. For this, scaffolds have to permit the formation of an intraluminal endothelial cell monolayer, mimicking the tunica intima. In addition, when attempting to mimic a tunica media‐like outer layer, the stacking and orientation of vascular smooth muscle cells (vSMCs) should be recapitulated. An integral scaffold design that facilitates this has so far remained a challenge. A hybrid fabrication approach is introduced by combining solution electrospinning and melt electrowriting. This allows a tissue‐structure mimetic, hierarchically bilayered tubular scaffold, comprising an inner layer of randomly oriented dense fiber mesh and an outer layer of microfibers with controlled orientation. The scaffold supports the organization of a continuous luminal endothelial monolayer and oriented layers of vSM‐like cells in the media, thus facilitating control over specific and tissue‐mimetic cellular differentiation and support of the phenotypic morphology in the respective layers. Neither soluble factors nor a surface bioactivation of the scaffold is needed with this approach, demonstrating that heterotypic scaffold design can direct physiological tissue‐like cell organization and differentiation.
Biofabrication is an advancing new research field that might, one day, lead to complex products like tissue replacements or tissue analogues for drug testing. Although great progress was made during the last years, there are still major hurdles like new types of materials and advanced processing techniques. The main focus of this thesis was to help overcoming this hurdles by challenging and improving existing fabrication processes like extrusion-based bioprinting but also by developing new techniques. Furthermore, this thesis assisted in designing and processing materials from novel building blocks like recombinant spider silk proteins or inks loaded with charged nanoparticles.
A novel 3D printing technique called Melt Electrospinning Writing (MEW) was used in Chapter 3 to create tubular constructs from thin polymer fibers (roughly 12 μm in diameter) by collecting the fibers onto rotating and translating cylinders. The main focus was put on the influence of the collector diameter and its rotation and translation on the morphology of the constructs generated by this approach. In a first step, the collector was not moving and the pattern generated by these settings was analyzed. It could be shown that the diameter of the stationary collectors had a big impact on the morphology of the constructs. The bigger the diameter of the mandrel (smallest collector diameters 0.5 mm, biggest 4.8 mm) got, the more the shape of the generated footprint converged into a circular one known from flat collectors. In a second set of experiments the mandrels were only rotated. Increasing the rotational velocity from 4.2 to 42.0 rpm transformed the morphology of the constructs from a figure-of-eight pattern to a sinusoidal and ultimately to a straight fiber morphology. It was possible to prove that the transformation of the pattern was comparable to what was known from increasing the speed using flat collectors and that at a critical speed, the so called critical translation speed, straight fibers would appear that were precisely stacking on top of each other. By combining rotation and translation of the mandrel, it was possible to print tubular constructs with defined winding angles. Using collections speeds close to the critical translation speed enabled higher control of fiber positioning and it was possible to generate precisely stacked constructs with winding angles between 5 and 60°.
In Chapter 4 a different approach was followed. It was based on extrusion-based bioprinting in combination with a hydrogel ink system. The ink was loaded with nanoparticles and the nanoparticle release was analyzed. In other words, two systems, a printable polyglycidol/hyaluronic acid ink and mesoporous silica nanoparticles (MSN), were combined to analyze charge driven release mechanism that could be fine-tuned using bioprinting. Thorough rheological evaluations proved that the charged nanoparticles, both negatively charged MSN-COOH and positively charged MSN-NH2, did not alter the shear thinning properties of the ink that revealed a negative base charge due to hyaluronic acid as one of its main components. Furthermore, it could be shown that the particles did also not have a negative effect on the recovery properties of the material after exposure to high shear. During printing, the observations made via rheological testing were supported by the fact that all materials could be printed at the same settings of the bioprinter. Using theses inks, it was possible to make constructs as big as 12x12x3 mm3 composed of 16 layers. The fiber diameters produced were about 627±31 μm and two-component constructs could be realized utilizing the two hydrogel print heads of the printer to fabricate one hybrid construct. The particle distribution within those constructs was homogeneous, both from a microscopic and a macroscopic point of view. Particle release from printed constructs was tracked over 6 weeks and revealed that the print geometry had an influence on the particle release. Printed in a geometry with direct contact between the strands containing different MSN, the positively charged particles quickly migrated into the strand previously containing only negatively charged MSN-COOH. The MSN-COOH seemed to be rather released into the surrounding liquid and also after 6 weeks no MSN-COOH signal could be detected in the strand previously only containing MSN-NH2. In case of a geometry without direct contact between the strands, the migration of the positively charged nanoparticles into the MSN-COOH containing strand was strongly delayed. This proved that the architecture of the printed construct can be used to fine-tune the particle release from nanoparticle containing printable hydrogel ink systems.
Chapter 5 discusses an approach using hydrogel inks based on recombinant spider silk proteins processed via extrusion-based bioprinting. The ink could be applied for printing at protein concentrations of 3 % w/v without the addition of thickeners or any post process crosslinking. Both, the recombinant protein eADF4(C16) and a modification introducing a RGD-sequence to the protein (eADF4(C16)-RGD), could be printed revealing a very good print fidelity. The RGD modification had positive effect on the adhesion of cells seeded onto printed constructs. Furthermore, human fibroblasts encapsulated in the ink at concentrations of 1.2 million cells per mL did not alter the print fidelity and did not interfere with the crosslinking mechanism of the ink. This enabled printing cell laden constructs with a cell survival rate of 70.1±7.6 %. Although the cell survival rate needs to be improved in further trials, the approach shown is one of the first leading towards the shift of the window of biofabrication because it is based on a new material that does not need potentially harmful post-process crosslinking and allows the direct encapsulation of cells staying viable throughout the print process.
Melt electrowriting, a high-resolution additive manufacturing technique, is used in this study to process a magnetic polymer-based blend for the first time. Carbonyl iron (CI) particles homogenously distribute into poly(vinylidene fluoride) (PVDF) melts to result in well-defined, highly porous structures or scaffolds comprised of fibers ranging from 30 to 50 µm in diameter. This study observes that CI particle incorporation is possible up to 30 wt% without nozzle clogging, albeit that the highest concentration results in heterogeneous fiber morphologies. In contrast, the direct writing of homogeneous PVDF fibers with up to 15 wt% CI is possible. The fibers can be readily displaced using magnets at concentrations of 1 wt% and above. Combined with good viability of L929 CC1 cells using Live/Dead imaging on scaffolds for all CI concentrations indicates that these formulations have potential for the usage in stimuli-responsive applications such as 4D printing.
Previous research on the melt electrowriting (MEW) of poly(vinylidene difluoride) (PVDF) resulted in electroactive fibers, however, printing more than five layers is challenging. Here, we investigate the influence of a heated collector to adjust the solidification rate of the PVDF jet so that it adheres sufficiently to each layer. A collector temperature of 110°C is required to improve fiber processing, resulting in a total of 20 fiber layers. For higher temperatures and higher layers, an interesting phenomenon occurred, where the intersection points of the fibers coalesced into periodic spheres of diameter 206 ± 52 μm (26G, 150°C collector temperature, 2000 mm/min, 10 layers in x- and y-direction).The heated collector is an important component of a MEW printer that allows polymers with a high melting point to be processable with increased layers.
This thesis identifies how the printing conditions for a high-resolution additive manufacturing technique, melt electrowriting (MEW), needs to be adjusted to process electroactive polymers (EAPs) into microfibers. Using EAPs based on poly(vinylidene difluoride) (PVDF), their ability to be MEW-processed is studied and expands the list of processable materials for this technology.
A novel approach, in the context of bioprinting, is the targeted printing of a defined number of cells at desired positions in predefined locations, which thereby opens up new perspectives for life science engineering. One major challenge in this application is to realize the targeted printing of cells onto a gel substrate with high cell survival rates in advanced bioinks. For this purpose, different alginate-dialdehyde—polyethylene glycol (ADA-PEG) inks with different PEG modifications and chain lengths (1–8 kDa) were characterized to evaluate their application as bioinks for drop on demand (DoD) printing. The biochemical properties of the inks, printing process, NIH/3T3 fibroblast cell distribution within a droplet and shear forces during printing were analyzed. Finally, different hydrogels were evaluated as a printing substrate. By analysing different PEG chain lengths with covalently crosslinked and non-crosslinked ADA-PEG inks, it was shown that the influence of Schiff's bases on the viscosity of the corresponding materials is very low. Furthermore, it was shown that longer polymer chains resulted in less stable hydrogels, leading to fast degradation rates. Several bioinks highly exhibit biocompatibility, while the calculated nozzle shear stress increased from approx. 1.3 and 2.3 kPa. Moreover, we determined the number of cells for printed droplets depending on the initial cell concentration, which is crucially needed for targeted cell printing approaches.
Designing of implant surfaces using a suitable ligand for cell adhesion to stimulate specific biological responses of stem cells will boost the application of regenerative implants. For example, materials that facilitate rapid and guided migration of stem cells would promote tissue regeneration. When seeded on fibronectin (FN) that was homogeneously immmobilized to NCO-sP(EO-stat-PO), which otherwise prevents protein binding and cell adhesion, human mesenchymal stem cells (MSC) revealed a faster migration, increased spreading and a more rapid organization of different cellular components for cell adhesion on fibronectin than on a glass surface. To further explore, how a structural organization of FN controls the behavior of MSC, adhesive lines of FN with varying width between 10 mu m and 80 mu m and spacings between 5 mu m and 20 mu m that did not allow cell adhesion were generated. In dependance on both line width and gaps, cells formed adjacent cell contacts, were individually organized in lines, or bridged the lines. With decreasing sizes of FN lines, speed and directionality of cell migration increased, which correlated with organization of the actin cytoskeleton, size and shape of the nuclei as well as of focal adhesions. Together, defined FN lines and gaps enabled a fine tuning of the structural organization of cellular components and migration. Microstructured adhesive substrates can mimic the extracellular matrix in vivo and stimulate cellular mechanisms which play a role in tissue regeneration.
Intraperitoneal adhesions are fibrous bands that connect tissues in the peritoneal cavity that are usually separated. These adhesions form as a consequence of trauma, inflammation or surgical interventions and often result in severe consequences such as chronic pain, small bowel obstructions or female infertility.
The aim of this thesis was to develop a synthetic barrier device for adhesion prevention made of modified poly(lactide) [PLA]. Solid PLA films (SurgiWrap®) are already successfully in clinical use due to the good biocompatibility and the biodegradability of the material resulting in non-toxic degradation products since lactic acid is naturally part of the metabolic circles of the human body. Considering the brittleness and stiffness of the films, the long degradation time of several months as well as the need for suturing, there is potential for optimization. Through a copolymerization with the hydrophilic poly(ethylene glycol) [PEG], a reduction of the degradation time was intendend. Moreover, the copolymerization should also lead to an improvement of the mechanical properties of the films since PEG acts as plasticizer for PLA. Linear PLA-PEG-PLA triblock copolymers as well as star-shaped PEG-PLA copolymers were synthesized via standard ring opening polymerization to tailor the barrier properties. Besides solid films, solution electrospun meshes from PLA and the synthesized PEG-PLA copolymers were investigated for a potential application as well. Since suturing of a barrier additionally induces adhesion formation, alginate coated membranes were prepared in order to achieve self-adhesiveness. With the intention to reduce infections and consequently inflammation, electrospun meshes and solvent cast films were loaded with the antibacterial drug triclosan and drug release as well as antibacterial efficacy was investigated.
Mechanical tests confirmed that through the variation of the PEG content and branching the mechanical properties can be tailored and are in good accordance with the glass transition temperatures [Tg] of the polymers. Consequently, potentially adequate mechanical properties for surgical handling as well as for the performance within the patient’s body were successfully achieved. Degradation studies revealed that the degradation time was significantly shorter for PEG-PLA membranes than for PLA films and with an appropriate PEG content could be adjusted to the intended time frame. Cell adhesion and viability tests confirmed the non-toxicity of the clinically used PLA films as well as of PEG-PLA films and meshes. With a bioadhesion test the benefit of an alginate coated side towards the pure PLA film concerning self-adhesiveness was successfully demonstrated. Moreover, optical evaluations and a T-peel test of different alginate coated PLA films showed that the cohesion between the chemically different layers was distinctly enhanced by the use of an appropriate PEG-PLA mesh as intermediate cohesion promoting layer. In in vitro release studies with triclosan loaded films a higher release was determined for PEG-PLA than for PLA films. In agar diffusion tests a higher and longer inhibition of staphylococcus aureus growth was observed confirming the release results. Moreover, drug loaded meshes (especially drug loaded after electrospinning) showed enhanced and elongated bacterial inhibition in comparison to films.
Calcium magnesium phosphate cements (CMPCs) are promising bone substitutes and experience great interest in research. Therefore, in-vivo degradation behavior, osseointegration and biocompatibility of three-dimensional (3D) powder-printed CMPC scaffolds were investigated in the present study. The materials Mg225 (Ca\(_{0.75}\)Mg\(_{2.25}\)(PO\(_4\))\(_2\)) and Mg225d (Mg225 treated with diammonium hydrogen phosphate (DAHP)) were implanted as cylindrical scaffolds (h = 5 mm, Ø = 3.8 mm) in both lateral femoral condyles in rabbits and compared with tricalcium phosphate (TCP). Treatment with DAHP results in the precipitation of struvite, thus reducing pore size and overall porosity and increasing pressure stability. Over 6 weeks, the scaffolds were evaluated clinically, radiologically, with Micro-Computed Tomography (µCT) and histological examinations. All scaffolds showed excellent biocompatibility. X-ray and in-vivo µCT examinations showed a volume decrease and increasing osseointegration over time. Structure loss and volume decrease were most evident in Mg225. Histologically, all scaffolds degraded centripetally and were completely traversed by new bone, in which the remaining scaffold material was embedded. While after 6 weeks, Mg225d and TCP were still visible as a network, only individual particles of Mg225 were present. Based on these results, Mg225 and Mg225d appear to be promising bone substitutes for various loading situations that should be investigated further.
In der vorliegenden Arbeit wurden unterschiedliche zementbasierte Knochenersatzmaterialien hinsichtlich ihres Potentials zur Behandlung knöcherner Defekte in vivo untersucht. Zwei verschiedene Calcium-dotierten Magnesiumphosphat Zementformulierungen (CMPC) wurden mit einem Referenzmaterial aus Calciumphosphat Zement (CPC) verglichen. Dazu wurden auf Basis von CMPC präfabrizierte, injizierbare Pasten bzw. sphärische Granulate hergestellt und anhand von orthotopen, potenziell kraftbelasteten Defekten in Kaninchenfemora getestet. Zentrales Ziel hierbei war es, herauszufinden, wie sich die Materialien in Defektsituationen mit Hartgewebekontakt biologisch verhalten und degradieren bzw. in Knochen umbauen. Nach einer Liegedauer von 6 bzw. 12 Wochen wurden die Knochenneubildung und die Degradation der Materialien mittels Histomorphometrie analysiert.
Alle Materialien waren biokompatibel und führten zur Bildung von neuem Knochen. Der CMPC-Zement zeigte im Vergleich zu CPC einen beschleunigten Abbau, während sich am Referenzmaterial mehr mineralisierter Knochen bildete. Die untersuchten Calcium-dotierten Struvit-bildenden Magnesiumphosphatzemente erwiesen sich als biokompatibel, gut resorbierbar und stellen mit ihrer Fähigkeit zur Knochenbildung ein vielversprechendes Knochenersatzmaterial dar.
Polymeric Janus Fibers
(2023)
Janus fibers are a class of composite materials comprising mechanical and chemical to biological functionality. Combining different materials and functionalities in one micro- or even nanoscale fiber enables otherwise unreachable synergistic physicochemical effects with unprecedented opportunities for technical or biomedical applications. Here, recent developments of processing technologies and applications of polymeric Janus fibers will be reviewed. Various examples in the fields of textiles, catalysis, sensors as well as medical applications, like drug delivery systems, tissue engineering and antimicrobial materials, are presented to illuminate the outstanding potential of such high-end functional materials for novel applications in the upcoming future.
Melt electrowriting, a high‐resolution additive manufacturing technology, has so far been developed with vertical stacking of fiber layers, with a printing trajectory that is constant for each layer. In this work, microscale layer shifting is introduced through deliberately offsetting the printing trajectory for each printed layer. Inaccuracies during the printing of sinusoidal walls are corrected via layer shifting, resulting in accurate control of their geometry and mechanical properties. Furthermore, more substantial layer shifting allows stacking of fiber layers in a horizontal manner, overcoming the electrostatic autofocusing effect that favors vertical layer stacking. Novel nonlinear geometries, such as overhangs, wall texturing and branching, and smooth and abrupt changes in printing trajectory are presented, demonstrating the flexibility of the layer shifting approach beyond the state‐of‐the‐art. The practice of microscale layer shifting for melt electrowriting enables more complex geometries that promise to have a profound impact on the development of products in a broad range of applications.
The aim of the thesis was to develop water soluble poly(2-oxazoline) (POx) copolymers with new side group functionalities, which can be used for the formation of hydrogels in biomedical applications and for the development of peptide-polymer conjugates.
First, random copolymers of the monomer MeOx or EtOx with ButEnOx and EtOx with DecEnOx were synthesized and characterized. The vinyl functionality brought into the copolymer by the monomers ButEnOx and DecEnOx would later serve for post-polymerization functionalization. The synthesized copolymers were further functionalized with thiols via post-polymerization functionalization using a newly developed synthesis protocol or with a protected catechol molecule for hydrogel formation. For the formation of peptide-polymer conjugates, a cyclic thioester, namely thiolactone acrylamide and an azlactone precursor, whose synthesis was newly developed, were attached to the side chain of P(EtOx-co-ButEnOx) copolymers.
The application of the functionalized thiol copolymers as hydrogels using thiol-ene chemistry for cross-linking was demonstrated. The swelling behavior and mechanical properties were characterized. The hydrophilicity of the network as well as the cross-linking density strongly influenced the swelling behavior and the mechanical strength of the hydrogels. All hydrogels showed good cell viability results.
The hydrogel networks based on MeOx and EtOx were loaded with two dyes, fluorescein and methylene blue. It was observed that the uptake of the more hydrophilic dye fluorescein depended more on the ability of the hydrogel to swell. In contrast, the uptake of the more hydrophobic dye methylene blue was less dependent on the swelling degree, but much more on the hydrophilicity of the network.
For the potential application as cartilage glue, (biohybrid) hydrogels were synthesized based on the catechol-functionalized copolymers, with and without additional fibrinogen, using sodium periodate as the oxidizing agent. The system allowed for degradation due to the incorporated ester linkages at the cross-linking points. The swelling behavior as well as the mechanical properties were characterized. As expected, hydrogels with higher degrees of cross-linking showed less swelling and higher elastic modulus. The addition of fibrinogen however increased the elasticity of the network, which can be favorable for the intended application as a cartilage glue. Biological evaluation clearly demonstrated the advantage of degradable ester links in the hydrogel network, where chondrocytes were able to bridge the artificial gap in contrast to hydrogels without any ester motifs.
Lastly, different ways to form peptide-polymer conjugates were presented. Peptides were attached with the thiol of the terminal cysteine group to the vinyl side chain of P(EtOx-co-ButEnOx) copolymers by radical thiol-ene chemistry. Another approach was to use a cyclic thioester, thiolactone, or an azlactone functionality to bind a model peptide via native chemical ligation. The two latter named strategies to bind peptides to POx side chains are especially interesting as one and in the case of thiolactone two free thiols are still present at the binding site after the reaction, which can, for example, be used for further thiol-ene cross-linking to form POx hydrogels.
In summary, side functional poly(oxazoline) copolymers show great potential for numerous biomedical applications. The various side chain functionalities can be introduced by an appropriate monomer or by post-polymerization functionalization, as demonstrated. By their multi-functionality, hydrogel characteristics, such as cross-linking degree and mechanical strength, can be fine-tuned and adjusted depending on the application in the human body. In addition, the presented chemoselective and orthogonal reaction strategies can be used in the future to synthesize polymer conjugates, which can, for example, be used in drug delivery or in tissue regeneration.
The physical and chemical stability of peptides for biomedical applications can be greatly enhanced through the conjugation of polymers. A well‐known but rather underemployed selective coupling functionality is the azlactone group, which readily reacts with a number of different nucleophiles without the need for activation and the formation of any by‐products. For example, azlactone functional polymers are used to react with peptides and proteins, rich in amino and thiol groups, to form polymeric beads for affinity‐based column chromatography. So far, side chain functional azlactone polymers have been mainly synthesized by radical polymerization using 2‐vinyl‐4,4‐dimethyl azlactone together with different acrylate monomers. Here, a new azlactone precursor equipped with a functional thiol is presented, which can be attached to any vinyl functional polymer by thiol–ene chemistry. Subsequently, the formation of the reactive azlactone ring can be performed in situ at high conversion rate without the need for illumination. This approach is tested on an azlactone side functional poly(2‐oxazoline) by coupling amine containing molecules including a model peptide and is proven via \(^1\)H NMR spectroscopy, IR spectroscopy, as well as HPLC measurements.
Der 3D-Druck ist ein elementarer Bestandteil der Biofabrikation. Beispielsweise wird mittels Biotinten und einem geeigneten 3D-Druckverfahren Schicht für Schicht eine Geometrie aufgebaut. Durch die Gestaltung von mikrofluidischen Druckköpfen wird eine Möglichkeit geschaffen multiple Materialansätze im Druckkopf zu vermischen und so in einem bestimmten Mischungsverhältnis zu drucken.
Mit dem DLP-SLA-Drucker Vida HD Crown and Bridge (EnvisionTEC) und dem Harz E-Shell 600 (EnvisionTEC) wurden zunächst die Auflösungsgrenzen des Druckers ermittelt sowie Komponenten für die Realisierung eines mikrofluidischen Druckkopfes prozessiert.
Bei den Komponenten handelt es sich zum einen um Geometrien, die beispielsweise als Mischeinheit im Kanal dienen können und des Weiteren um senkrechte Kanäle die Biotinten führen können, sowie um Kanäle, die als Zuläufe für den Hauptkanal des mikrofluidischen Druckkopfs dienen können.
Die Eigenschaften und die technische Realisierbarkeit der gedruckten Objekte wurden eruiert.
Dabei wurden die jeweiligen Geometrien und Kanalöffnungen vermessen, große Aspektverhältnisse der Geometrien untersucht und die Durchgängigkeit der Kanäle geprüft.
Zukünftig können die prozessierten Komponenten für einen mikrofluidischen Druckkopf variabel kombiniert werden und auf dieser Basis weiterführende Experimente stattfinden.
Bioprinting has emerged as a valuable threedimensional (3D) biomanufacturing method to fabricate complex hierarchical cell-containing constructs. Spanning from basic research to clinical translation, sterile starting materials are crucial. In this study, we present pharmacopeia compendial sterilization methods for the commonly used bioink component alginate. Autoclaving (sterilization in saturated steam) and sterile filtration followed by lyophilization as well as the pharmacopeia non-compendial method, ultraviolet (UV)-irradiation for disinfection, were assessed. The impact of the sterilization methods and their effects on physicochemical and rheological properties, bioprinting outcome, and sterilization efficiency of alginate were detailed. Only sterile filtration followed by lyophilization as the sterilization method retained alginate's physicochemical properties and bioprinting behavior while resulting in a sterile outcome. This set of methods provides a blueprint for the analysis of sterilization effects on the rheological and physicochemical pattern of bioink components and is easily adjustable for other polymers used in the field of biofabrication in the future.
Purpose: The topical application of tranexamic acid (TXA) into the joint space during total joint arthroplasty (TJA) with no increase of complications, has been widely reported. We investigated the influence of TXA on antibiotic release, activity of the released antibiotic against a clinical isolate of S. aureus, and compressive strength of a widely used commercially prepared gentamicin-loaded cement brand (PALACOS R + G). Method: 12 bone cement cylinders (diameter and height = 6 and 12 mm, respectively) were molded. After curing in air for at least 1 h, six of the cylinders were completely immersed in 5 mL of fetal calf serum (FCS) and the other six were completely immersed in a solution consisting of 4.9 mL of FCS and 0.1 mL (10 mg) of TXA. Gentamicin elution tests were performed over 7 d. Four hundred µL of the gentamicin eluate were taken every 24 h for the first 7 d without renewing the immersion fluid. The gentamicin concentration was determined in a clinical analyzer using a homogeny enzyme immuno-assay. The antimicrobial activity of the eluate, obtained after day 7, was tested. An agar diffusion test regime was used with Staphylococcus aureus. Bacteria were grown in a LB medium and plated on LB agar plates to get a bacterial lawn. Fifty µL of each eluate were pipetted on 12-mm diameter filter discs, which were placed in the middle of the agar gel. After 24 h of cultivation at 37 °C, the zone of inhibition (ZOI) for each specimen was measured. The compressive strength of the cements was determined per ISO 5833. Results: At each time point in the gentamicin release test, the difference in gentamicin concentration, obtained from specimens immersed in the FCS solution only and those immersed in the FCS + TXA solution was not significant (p = 0.055–0.522). The same trend was seen in each of the following parameters, after 7 d of immersion: (1) Cumulative gentamicin concentration (p < 0.297); (2) gentamicin activity against S. aureus (strongly visible); (3) ZOI size (mostly > 20 mm) (p = 0.631); and (4) compressive strength (p = 0.262). Conclusions: For the PALACOS R + G specimens, the addition of TXA to FCS does not produce significant decreases in gentamicin concentration, in the activity of the gentamicin eluate against a clinical isolate of S. aureus, the zone of inhibition of S. aureus, and in the compressive strength of the cement, after 7 d of immersion in the test solution.
Es wurde die Expression der osteogenen Markerproteine Alkalische Phosphatase, Bone Sialoprotein, Kollagen Typ I und Osteopontin von humanen mesenchymalen Stromazellen nach Kultur auf elektrogesponnenen Scaffolds analysiert. Die Scaffolds wurden mittels der Melt electrospinning writing Methode erstellt und unterschieden sich in ihrer Maschenweite. Anhand weiterer Kontrollversuche auf Monolayern wurde ein möglicher Einfluss der Geometrie auf die Proteinexpression untersucht.
Hydrophilic (AB)\(_{n}\) Segmented Copolymers for Melt Extrusion‐Based Additive Manufacturing
(2021)
Several manufacturing technologies beneficially involve processing from the melt, including extrusion‐based printing, electrospinning, and electrohydrodynamic jetting. In this study, (AB)\(_{n}\) segmented copolymers are tailored for melt‐processing to form physically crosslinked hydrogels after swelling. The copolymers are composed of hydrophilic poly(ethylene glycol)‐based segments and hydrophobic bisurea segments, which form physical crosslinks via hydrogen bonds. The degree of polymerization was adjusted to match the melt viscosity to the different melt‐processing techniques. Using extrusion‐based printing, a width of approximately 260 µm is printed into 3D constructs, with excellent interlayer bonding at fiber junctions, due to hydrogen bonding between the layers. For melt electrospinning, much thinner fibers in the range of about 1–15 µm are obtained and produced in a typical nonwoven morphology. With melt electrowriting, fibers are deposited in a controlled way to well‐defined 3D constructs. In this case, multiple fiber layers fuse together enabling constructs with line width in the range of 70 to 160 µm. If exposed to water the printed constructs swell and form physically crosslinked hydrogels that slowly disintegrate, which is a feature for soluble inks within biofabrication strategies. In this context, cytotoxicity tests confirm the viability of cells and thus demonstrating biocompatibility of this class of copolymers.
Infektionen von Endoprothesen sind auch heute noch, obgleich aufgrund aktueller Hygienestandards seltener, eine schwerwiegende Komplikation. Die Folgen können risikoreiche Revisionsoperationen bis hin zum kompletten Prothesenverlust sein. Um die Gefahr bakterieller Protheseninfektionen zu minimieren, rückten unter anderem Oberflächenbeschichtungen mit antimikrobieller Wirkung in den Fokus der Forscher. Eine Kombination aus dem antimikrobiell wirksamen Metall Silber und dem die Härte verbessernden Stickstoff – als TiAgN – Beschichtung – zeigte bereits gute in vitro Ergebnisse (Moseke et al. 2011).
Auf Grundlage dieser positiven in vitro Studie wurde die TiAgN – Beschichtung in der hier vorliegenden Arbeit in vivo im Tiermodell untersucht. Ziel der Studie war es das Einwachsen TiAgN – beschichteter Titanimplantate im Kaninchenknochen mit unbeschichteten Titanimplantaten zu vergleichen. Hierzu wurden bei insgesamt drei Kaninchen jeweils zwei TiAgN – beschichtete Proben und eine unbeschichtete Kontrolle in beide Femora implantiert. Der Einheilzeitraum betrug drei Monate.
Nach der Entnahme der Femora wurde zunächst durch Röntgenaufnahmen die genaue Lage der Implantate festgesellt. Nach der Anfertigung von Dünnschliffen nach Donath und der Trichrom – Färbung nach Masson – Goldner wurden für die histologische Auswertung lichtmikroskopische Bilder in 40 – facher Vergrößerung angefertigt. Um den gesamten Umfang der Implantatanschnitte vermessen zu können, wurden die aufgenommen Einzelbilder zu den ursprünglichen Gesamtbildern zusammengesetzt. Die Vermessung der Implantatumfänge erfolgte hinsichtlich der Untersuchungsparameter Knochen – Implantat – Kontakt (KIK), nicht mineralisierter Knochen (Osteoid), Bindegewebe und Spalten – Implantatoberflächenbereiche an denen kein Gewebe angewachsen ist. Für die drei beobachteten Kaninchen ergab sich für die TiAgN – beschichteten Probeimplantate ein KIK von 94,87 %, ein Osteoidanteil am KIK von 45,15 % und ein Spaltanteil von 2,82 % verglichen mit den unbeschichteten Kontrollen von 97,31 % für den KIK, 60,12 % für den Osteoid – sowie 2,69 % für den Spaltanteil. Somit zeigt sich für TiAgN – beschichtete Titanimplantate kein signifikant schlechteres Einwachsen im Vergleich zu unbeschichteten Titanimplantaten.
Ausgehend von der guten antimikrobiellen Wirksamkeit und Zytokompatibilität in vitro (Moseke et al. 2011) sowie der guten Osseointegration in vivo präsentiert sich diese Beschichtung sehr vielversprechend. Dennoch sind weitere Untersuchungen erforderlich, wie beispielsweise die Überprüfung der Haftfestigkeit zwischen Beschichtung und Implantat sowie die antimikrobielle Wirksamkeit in vivo. Ergeben sich für diese Beschichtung weiterhin gute Ergebnisse, kann eine Studie am Menschen in Erwägung gezogen werden.
The main focus of this thesis was the processing of different calcium and magnesium phosphate cements together with an optimization of mechanical and biological properties. Therefore, different manufacturing techniques like 3D powder printing and centrifugally casting were employed for the fabrication of reinforced or biomedically improved implants.
One of the main problems during 3D powder printing is the low green strength of many materials, especially when they are only physically bonded and do not undergo a setting reaction. Such materials need post-treatments like sintering to exhibit their full mechanical performance. However, the green bodies have to be removed from the printer requiring a certain stability. With the help of fiber reinforcement, the green strength of printed gypsum samples could be increased by the addition of polymeric and glass fibers within the printing process. The results showed that fiber reinforcement during 3D powder printing is possible and opens up diverse opportunities to enhance the damage tolerance of green bodies as well as directly printed samples. The transfer to biomedically relevant materials like calcium and magnesium phosphate cements and biocompatible fibers would be the next step towards reinforced patient-specific implants.
In a second approach, centrifugally casting derived from construction industries was established for the fabrication of hollow bioceramic cylinders. The aim was the replacement of the diaphysis of long bones, which exhibit a tubular structure with a high density of cortical bone on the fringe. By centrifugation, cement slurries with and without additives could be fabricated to tubes. As a first establishment, the processing parameters regarding the material (e.g. cement composition) as well as the set-up (e.g. rotation times) had to be optimized for each system. In respect of mechanics, such tubes can keep up with 3D powder printed tubes, although the mechanical performance of 3D printed tubes is strongly dependent on printing directions. Additionally, some material compositions like dual setting systems cannot be fabricated by 3D powder printing. Therefore, a transfer of such techniques to centrifugally casting enabled the fabrication of tubular structures with an extremely high damage tolerance due to high deformation ability. A similar effect was achieved by fiber (mesh) addition, as already shown for 3D powder printing. Another possibility of centrifugally casting is the combination of different materials resulting in graded structures to adjust implant degradation or bone formation. This became especially apparent for the incorporation of the antibiotic vancomycin, which is used for the treatment of bacterial implant infections. A long-term release could be achieved by the entrapment of the drug between magnesium phosphate cement layers. Therefore, the release of the drug could be regulated by the degradation of the outer shell, which supports the release into an acidic bacterial environment. The centrifugally casting technique exhibited to be a versatile tool for numerous materials and applications including the fabrication of non-centrosymmetric patient-specific implants for the reconstruction of human long bones.
The third project aimed to manufacture strontium-substituted magnesium phosphate implants with improved biological behavior by 3D powder printing. As the promoting effect of strontium on bone formation and the inhibitory impact on bone resorption is already well investigated, the incorporation of strontium into a degradable magnesium phosphate cement promised a fast integration and replacement of the implant. Porous structures were obtained with a high pore interconnectivity that is favorable for cell invasion and bone ingrowth. Despite the porosity, the mechanical performance was comparable to pure magnesium phosphate cement with a high reliability of the printed samples as quantitatively determined by Weibull statistics. However, the biological testing was impeded by the high degradation rate and the relating ion release. The high release of phosphate ions into surrounding media and the detachment of cement particles from the surface inhibited osteoblast growth and activity. To distinguish those two effects, a direct and indirect cell seeding is always required for degradable materials. Furthermore, the high phosphate release compared to the strontium release has to be managed during degradation such that the adverse effect of phosphate ions does not overwhelm the bone promoting effect of the strontium ions.
The manufacturing techniques presented in this thesis together with the material property improvement offer a diverse tool box for the fabrication of patient-specific implants. This includes not just the individual implant shape but also the application like bone growth promotion, damage tolerance and local drug delivery. Therefore, this can act as the basis for further research on specific medical indications.
In modern medicine hip and knee joint replacement are common surgical procedures. However, about 11 % of hip implants and about 7 % of knee implants need re-operations. The comparison of implant registers revealed two major indications for re-operations: aseptic loosening and implant infections, that both severely impact the patients’ health and are an economic burden for the health care system. To address these problems, a calcium hydroxide coating on titanium was investigated in this thesis. Calcium hydroxide is a well-known antibacterial agent and used with success in dentistry. The coatings were applied with electrochemically assisted deposition, a versatile tool that combines easiness of process with the ability to coat complex geometries homogeneously. The pH-gradient during coating was investigated and showed the surface confinement of the coating process. Surface pre-treatment altered the surface morphology and chemistry of the titanium substrates and was shown to affect the morphology of the calcium hydroxide coatings. The influence of the coating parameters stirring speed and current pulsing were examined in various configurations and combinations and could also affect the surface morphology. A change in surface morphology results in a changed adhesion and behavior of cells and bacteria. Thus, the parameters surface pre-treatment, stirring speed and current pulsing presented a toolset for tailoring cellular response and antibacterial properties. Microbiological tests with S. aureus and S. epidermidis were performed to test the time-dependent antibacterial activity of the calcium hydroxide coatings. A reduction of both strains could be achieved for 13 h, which makes calcium hydroxide a promising antibacterial coating. To give insight into biofilm growth, a protocol for biofilm staining was investigated on titanium disks with S. aureus and S. epidermidis. Biofilm growth could be detected after 5 days of bacterial incubation, which was much earlier than the 3 weeks that are currently assumed in medical treatment. Thus, it should be considered to treat infections as if a biofilm were present from day 5 on. The ephemeral antibacterial properties of calcium hydroxide were further enhanced and prolonged with the addition of silver and copper ions. Both ionic modifications significantly enhanced the bactericidal potential. The copper modification showed higher antibacterial effects than the silver modification and had a higher cytocompatibility which was comparable to the pure calcium hydroxide coating. Thus, copper ions are an auspicious option to enhance the antibacterial properties. Calcium hydroxide coatings presented in this thesis have promising antibacterial properties and can easily be applied to complex geometries, thus they are a step in fighting aseptic loosening and implant infections.
Dicalcium phosphate cement preparation requires the addition of setting retarders to meet clinical requirements regarding handling time and processability. Previous studies have focused on the influence of different setting modifiers on material properties such as mechanical performance or injectability, while ignoring their influence on biological cement properties as they are used in low concentrations in the cement pastes and the occurrence of most compounds in human tissues. Here, analyses of both material and biological behavior were carried out on samples with common setting retardants (citric acid, sodium pyrophosphate, sulfuric acid) and novel (phytic acid). Cytocompatibility was evaluated by in vitro tests with osteoblastic (hFOB 1.19) and osteoclastic (RAW 264.7) cells. We found cytocompatibility was better for sodium pyrophosphate and phytic acid with a three-fold cell metabolic activity by WST-1 test, whereas samples set with citric acid showed reduced cell number as well as cell activity. The compressive strength (CS) of cements formed with phytic acid (CS = 13 MPa) were nearly equal to those formed with citric acid (CS = 15 MPa) and approximately threefold higher than for other setting retardants. Due to a proven cytocompatibility and high mechanical strength, phytic acid seems to be a candidate replacement setting retardant for dicalcium phosphate cements.
Melt electrowriting (MEW) is a high-resolution additive manufacturing technology that balances multiple parametric variables to arrive at a stable fabrication process. The better understanding of this balance is underscored here using high-resolution camera vision of jet stability profiles in different electrical fields. Complementing this visual information are fiber-diameter measurements obtained at precise points, allowing the correlation to electrified jet properties. Two process signatures—the jet angle and for the first time, the Taylor cone area—are monitored and analyzed with a machine vision system, while SEM imaging for diameter measurement correlates real-time information. This information, in turn, allows the detection and correction of fiber pulsing for accurate jet placement on the collector, and the in-process assessment of the fiber diameter. Improved process control is used to successfully fabricate collapsible MEW tubes; structures that require exceptional accuracy and printing stability. Using a precise winding angle of 60° and 300 layers, the resulting 12 mm-thick tubular structures have elastic snap-through instabilities associated with mechanical metamaterials. This study provides a detailed analysis of the fiber pulsing occurrence in MEW and highlights the importance of real-time monitoring of the Taylor cone volume to better understand, control, and predict printing instabilities.
Im Rahmen dieser Arbeit sollte herausgefunden werden, inwiefern Calciumorthophosphatzemente (CPC) dafür geeignet sind, um als Prüfkörper zur Qualifizierung von Knochenklebern zu dienen, und worin ihre Limitationen bestehen. Dazu sollte nicht nur ein materieller Vergleich verschiedener hydroxylapatitbildender Zemente mit Knochen erfolgen. Es sollte auch das Adhäsionsverhalten neuartiger Knochenkleber auf den verschiedenen Prüfkörpermaterialien verglichen werden, um mögliche Rückschlüsse für die Eignung als standardisierbares in-vitro Prüfkörpermaterial ziehen zu können.
Gegenstand der Untersuchung war ein α-Tricalciumphosphat (α-TCP)-System und ein Tetracalciumphosphat (TTCP)-System welche im Rahmen einer Zement-Abbindereaktion calciumdefizitären Hydroxylapatit (CDHA) bzw. stöchiometrischen Hydroxylapatit (HA) bilden. Die Materialien wurden dazu verwendet Prüfkörperteile in Form von Zylindern (5 x 5 mm) und Plättchen (20 x 10 x 5 mm) herzustellen, die dann mit verschiedenen Knochenklebern verklebt werden konnten. Der stärkste der verwendeten Kleber war ein Cyanoacrylat-Kleber (Truglue®). Er erzielte auf Prüfkörpern aus Knochen nach 24-stündiger Lagerung in PBS mittlere Abscherfestigkeiten von ca. 4,22 ± 1,92 MPa. Als zweitstärkster Kleber erwies sich ein neuartiger zementbasierter Kleber, der aus wärmebehandeltem Trimagnesiumphosphat-Hydrat und Phosphoserin bestand. Dieser Kleber erzielte unter den gleichen Umständen mittlere Abscherfestigkeiten von ca. 1,89 ± 0,29 MPa. Etwas schwächer schnitt ein ebenfalls neuartiger zementbasierter Kleber ab, der aus dem Magnesiumphosphat Farringtonit, sowie aus Magnesiumoxid und 25 % Phytinsäure bestand. Dieser Kleber erzielte mittlere Abscherfestigkeiten von ca. 0,51 ± 0,16 MPa. Insgesamt haben die Untersuchungen gezeigt, dass die in-vitro Qualifizierung von Knochenklebern unter Verwendung von Prüfkörpern aus Zement möglich wäre. Die Prüfkörper aus CDHA vereinten die meisten Vorteile und wären für Klebesysteme mit Abscherfestigkeiten von bis zu 2 MPa geeignet. Dabei erzeugten die Knochenkleber auf CDHA zwar abweichende Abscherfestigkeiten als auf Knochen, doch ließ sich ein vergleichbarer Trend bei stets reduzierten Varianzen erkennen. Durch die gute Konsistenz der Zementpaste war die Herstellung homogener Prüfkörper möglich. Aufgrund der Stabilität von CDHA unter wässrigen Bedingungen konnten Langzeitversuche ohne Einschränkungen vorgenommen werden. Die Limitationen der Prüfkörper aus CDHA bestanden allerdings darin, dass sie nicht für Abscherversuche von stärkeren Klebern geeignet waren. In solchen Fällen versagten die Prüfkörper noch bevor die maximale Abscherfestigkeit des jeweiligen Klebers gemessen werden konnte.
Fabrication of microchannels using 3D printing of sugars as fugitive material is explored in different fields, including microfluidics. However, establishing reproducible methods for the controlled production of sugar structures with sub-100 μm dimensions remains a challenge.
This study pioneers the processing of sugars by melt electrowriting (MEW) enabling the fabrication of structures with so far unprecedented resolution from Isomalt. Based on a systematic variation of process parameters, fibers with diameters down to 20 μm can be fabricated. The flexibility in the adjustment of fiber diameter by on-demand alteration of MEW parameters enables generating constructs with perfusable channels within polydimethylsiloxane molds. These channels have a diameter that can be adjusted from 30 to 200 μm in a single design.
Taken together, the experiments show that MEW strongly benefits from the thermal and physical stability of Isomalt, providing a robust platform for the fabrication of small-diameter embedded microchannel systems.
Knorpeldefekte gelten in der Medizin als besonders schwierig zu beheben, da das avaskuläre und aneurale hyaline Knorpelgewebe nur über sehr begrenzte Selbstheilungskräfte verfügt. Die Entwicklung neuer klinischer Therapien für eine erfolgreiche Regeneration bis hin zum vollständigen Ersatz von beschädigtem oder erkranktem Knorpel stellt daher das Ziel umfangreicher Forschung dar. Darüber hinaus zeichnet sich Knorpel durch eine organisierte, zonale Zell-Matrix-Verteilung und -Dichte aus, die möglichst naturgetreu nachgebildet werden muss, um einen adäquaten Gelenkknorpelersatz zu schaffen. Das dreidimensionale Bioprinting von humanen mesenchymalen Stromazellen (hMSCs) in Hydrogelen ist hierbei ein vielversprechender Ansatz. Es sind jedoch umfangreiche Studien erforderlich, um herauszufinden, wie 3D-Stammzellkonstrukte mit unterschiedlichen Zelldichten und Zell-Zell-Wechselwirkungen in einer gedruckten Hydrogel Matrix interagieren. Deshalb wurde in dieser Arbeit untersucht, ob die mesenchymalen Stromazellen in Form von Einzelzellen oder Sphäroiden durch das Extrusionsdruckverfahren in ihrer Proliferationsfähigkeit und ihrem chondrogenen Differenzierungspotential beeinträchtigt werden.
Hierfür wurden in dieser Arbeit sowohl das Zellüberleben als auch Proliferations- und Differenzierungsmarker in gedruckten und nicht gedruckten Proben mit Einzelzellkonzentrationen von 2-20 Millionen Zellen sowie bei Sphäroiden mit ca 4000 Zellen/Sphäroid untersucht. Es konnte gezeigt werden, dass das extrusionsbasierte Druckverfahren keine negativen Auswirkungen auf die Überlebensfähigkeit und die Proliferation der hMSCs hat. Zum Nachweis der chondrogenen Differenzierung wurden mehrere Experimente durchgeführt. Durch die Expression von Typ-II-Kollagen und Aggrecan sowie durch die Quantifizierung von GAG welches zu einem großen Teil in der ECM von Knorpelgewebe zu finden ist, konnte bestätigt werden, dass die mesenchymalen Stromazellen durch den Druckprozess ihr chondrogenes Differenzierungspotential nicht einbüßen. Die beim 3D-Bioprinting auftretenden Scherkräfte scheinen die in-vitro Chondrogenese sogar ohne chemische Stimulation durch TGF-β1 anzustoßen. Außerdem zeigten die Sphäroidgruppen ein höheres chondrogenes Differenzierungspotential als die Einzelzellgruppen.
Um dies im Zusammenhang mit dem 3D Extrusionsdruckverfahren zu bestätigen, erscheint es sinnvoll, weitere Versuche mit noch höheren Zellkonzentrationen in Form von Sphäroiden durchzuführen. Zusammenfassend zeigte sich in dieser Arbeit, dass das extrusionsbasierte Druckverfahren in Alginat/Gelatine Hydrogelen keine Zellschädigung verursacht und weder die chondrogene Differenzierung von Einzelzellen noch von Sphäroiden beeinträchtigt.
Brushite cements have been clinically used for irregular bone defect filling applications, and various strategies have been previously reported to modify and improve their physicochemical properties such as strength and injectability. However, strategies to address other limitations of brushite cements such as low radiopacity or acidity without negatively impacting mechanical strength have not yet been reported. In this study, we report the effect of substituting the beta-tricalcium phosphate reactant in brushite cement with baghdadite (Ca\(_3\)ZrSi\(_2\)O\(_9\)), a bioactive zirconium-doped calcium silicate ceramic, at various concentrations (0, 5, 10, 20, 30, 50, and 100 wt%) on the properties of the final brushite cement product. X-ray diffraction profiles indicate the dissolution of baghdadite during the cement reaction, without affecting the crystal structure of the precipitated brushite. EDX analysis shows that calcium is homogeneously distributed within the cement matrix, while zirconium and silicon form cluster-like aggregates with sizes ranging from few microns to more than 50 µm. X-ray images and µ-CT analysis indicate enhanced radiopacity with increased incorporation of baghdadite into brushite cement, with nearly a doubling of the aluminium equivalent thickness at 50 wt% baghdadite substitution. At the same time, compressive strength of brushite cement increased from 12.9 ± 3.1 MPa to 21.1 ± 4.1 MPa with 10 wt% baghdadite substitution. Culture medium conditioned with powdered brushite cement approached closer to physiological pH values when the cement is incorporated with increasing amounts of baghdadite (pH = 6.47 for pure brushite, pH = 7.02 for brushite with 20 wt% baghdadite substitution). Baghdadite substitution also influenced the ionic content in the culture medium, and subsequently affected the proliferative activity of primary human osteoblasts in vitro. This study indicates that baghdadite is a beneficial additive to enhance the radiopacity, mechanical performance and cytocompatibility of brushite cement
Augmenting the vascular supply to generate new tissues, a crucial aspect in regenerative medicine, has been challenging. Recently, our group showed that calcium phosphate can induce the formation of a functional neo-angiosome without the need for microsurgical arterial anastomosis. This was a preclinical proof of concept for biomaterial-induced luminal sprouting of large-diameter vessels. In this study, we investigated if sprouting was a general response to surgical injury or placement of an inorganic construct around the vessel. Cylindrical biocement scaffolds of differing chemistries were placed around the femoral vein. A contrast agent was used to visualize vessel ingrowth into the scaffolds. Cell populations in the scaffold were mapped using immunohistochemistry. Calcium phosphate scaffolds induced 2.7–3 times greater volume of blood vessels than calcium sulphate or magnesium phosphate scaffolds. Macrophage and vSMC populations were identified that changed spatially and temporally within the scaffold during implantation. NLRP3 inflammasome activation peaked at weeks 2 and 4 and then declined; however, IL-1β expression was sustained over the course of the experiment. IL-8, a promoter of angiogenesis, was also detected, and together, these responses suggest a role of sterile inflammation. Unexpectedly, the effect was distinct from an injury response as a result of surgical placement and also was not simply a foreign body reaction as a result of placing a rigid bioceramic next to a vein, since, while the materials tested had similar microstructures, only the calcium phosphates tested elicited an angiogenic response. This finding then reveals a potential path towards a new strategy for creating better pro-regenerative biomaterials.
The development and formulation of printable inks for extrusion-based 3D bioprinting has been a major challenge in the field of biofabrication. Inks, often polymer solutions with the addition of crosslinking to form hydrogels, must not only display adequate mechanical properties for the chosen application but also show high biocompatibility as well as printability. Here we describe a reproducible two-step method for the assessment of the printability of inks for bioprinting, focussing firstly on screening ink formulations to assess fibre formation and the ability to form 3D constructs before presenting a method for the rheological evaluation of inks to characterise the yield point, shear thinning and recovery behaviour. In conjunction, a mathematical model was formulated to provide a theoretical understanding of the pressure-driven, shear thinning extrusion of inks through needles in a bioprinter. The assessment methods were trialled with a commercially available crème, poloxamer 407, alginate-based inks and an alginate-gelatine composite material. Yield stress was investigated by applying a stress ramp to a number of inks, which demonstrated the necessity of high yield for printable materials. The shear thinning behaviour of the inks was then characterised by quantifying the degree of shear thinning and using the mathematical model to predict the window of printer operating parameters in which the materials could be printed. Furthermore, the model predicted high shear conditions and high residence times for cells at the walls of the needle and effects on cytocompatibility at different printing conditions. Finally, the ability of the materials to recover to their original viscosity after extrusion was examined using rotational recovery rheological measurements. Taken together, these assessment techniques revealed significant insights into the requirements for printable inks and shear conditions present during the extrusion process and allow the rapid and reproducible characterisation of a wide variety of inks for bioprinting.
Melt electrowriting (MEW) is an additive manufacturing process that produces highly defined constructs with elements in the micrometer range. A specific configuration of MEW enables printing tubular constructs to create small-diameter tubular structures. The small pool of processable materials poses a bottleneck for wider application in biomedicine. To alleviate this obstacle, an acrylate-endcapped urethane-based polymer (AUP), using a poly(ε-caprolactone) (PCL) (molar mass: 20 000 g mol\(^{−1}\)) (AUP PCL20k) as backbone material, is synthesized and utilized for MEW. Spectroscopic analysis confirms the successful modification of the PCL backbone with photo-crosslinkable acrylate endgroups. Printing experiments of AUP PCL20k reveal limited printability but the photo-crosslinking ability is preserved post-printing. To improve printability and to tune the mechanical properties of printed constructs, the AUP-material is blended with commercially available PCL (AUP PCL20k:PCL in ratios 80:20, 60:40, 50:50). Print fidelity improves for 60:40 and 50:50 blends. Blending enables modification of the constructs' mechanical properties to approximate the range of blood vessels for transplantation surgeries. The crosslinking-ability of the material allows pure AUP to be manipulated post-printing and illustrates significant differences in mechanical properties of 80:20 blends after crosslinking. An in vitro cell compatibility assay using human umbilical vein endothelial cells also demonstrates the material's non-cytotoxicity.
In this work, a toolbox was provided to create three-component polymer conjugates with a defined architecture, designed to bear different biocomponents that can interact with larger biological systems in biomacromolecular recognition experiments. The target architecture is the attachment of two biomolecule ‘arms’ to the alpha telechelic end point of a polymer and fixating the conjugate to the gold surface of SAW and SPR sensor chips with the polymer’s other omega chain end. This specific design of a conjugate will be implemented by using a strategy to yield novel double alpha as well as omega telechelic functionalized POx and the success of all cascade reaction steps leading to the final conjugation product will be proven through affinity measurements between covalently bound mannose and ConA. All reactions were performed on a low molecular model level first and then transferred to telechelic and also side chain functionalized polymer systems.
Interactions between proteins and carbohydrates with larger biomacromolecules, e.g., lectins, are usually examined using self-assembled monolayers on target gold surfaces as a simplified model measuring setup. However, most of those measuring setups are either limited to a single substrate or do not allow for control over ligand distance and spacing. Here, we develop a synthetic strategy, consisting of a cascade of a thioesterification, native chemical ligation (NCL) and thiol-ene reaction, in order to create three-component polymer conjugates with a defined double bioactivation at the chain end. The target architecture is the vicinal attachment of two biomolecule residues to the α telechelic end point of a polymer and a thioether group at the ω chain end for fixating the conjugate to a gold sensor chip surface. As proof-of-principle studies for affinity measurements, we demonstrate the interaction between covalently bound mannose and ConA in surface acoustic wave (SAW) and surface plasmon resonance (SPR) experiments.
Myocardial infarction (MI) induces a complex inflammatory immune response, followed by the remodelling of the heart muscle and scar formation. The rapid regeneration of the blood vessel network system by the attraction of hematopoietic stem cells is beneficial for heart function. Despite the important role of chemokines in these processes, their use in clinical practice has so far been limited by their limited availability over a long time-span in vivo. Here, a method is presented to increase physiological availability of chemokines at the site of injury over a defined time-span and simultaneously control their release using biodegradable hydrogels. Two different biodegradable hydrogels were implemented, a fast degradable hydrogel (FDH) for delivering Met-CCL5 over 24hrs and a slow degradable hydrogel (SDH) for a gradual release of protease-resistant CXCL12 (S4V) over 4weeks. We demonstrate that the time-controlled release using Met-CCL5-FDH and CXCL12 (S4V)-SDH suppressed initial neutrophil infiltration, promoted neovascularization and reduced apoptosis in the infarcted myocardium. Thus, we were able to significantly preserve the cardiac function after MI. This study demonstrates that time-controlled, biopolymer-mediated delivery of chemokines represents a novel and feasible strategy to support the endogenous reparatory mechanisms after MI and may compliment cell-based therapies.
Bioactive glass (BG) scaffolds are being investigated for bone tissue engineering applications because of their osteoconductive and angiogenic nature. However, to increase the in vivo performance of the scaffold, including enhancing the angiogenetic growth into the scaffolds, some researchers use different modifications of the scaffold including addition of inorganic ionic components to the basic BG composition. In this study, we investigated the in vitro biocompatibility and bioactivity of Cu2+-doped BG derived scaffolds in either BMSC (bone-marrow derived mesenchymal stem cells)-only culture or co-culture of BMSC and human dermal microvascular endothelial cells (HDMEC). In BMSC-only culture, cells were seeded either directly on the scaffolds (3D or direct culture) or were exposed to ionic dissolution products of the BG scaffolds, kept in permeable cell culture inserts (2D or indirect culture). Though we did not observe any direct osteoinduction of BMSCs by alkaline phosphatase (ALP) assay or by PCR, there was increased vascular endothelial growth factor (VEGF) expression, observed by PCR and ELISA assays. Additionally, the scaffolds showed no toxicity to BMSCs and there were healthy live cells found throughout the scaffold. To analyze further the reasons behind the increased VEGF expression and to exploit the benefits of the finding, we used the indirect method with HDMECs in culture plastic and Cu2+-doped BG scaffolds with or without BMSCs in cell culture inserts. There was clear observation of increased endothelial markers by both FACS analysis and acetylated LDL (acLDL) uptake assay. Only in presence of Cu2+-doped BG scaffolds with BMSCs, a high VEGF secretion was demonstrated by ELISA; and typical tubular structures were observed in culture plastics. We conclude that Cu2+-doped BG scaffolds release Cu2+, which in turn act on BMSCs to secrete VEGF. This result is of significance for the application of BG scaffolds in bone tissue engineering approaches.
Knochenklebstoffe, welche eine unkonventionelle Möglichkeit im Bereich der chirurgischen Frakturversorgung darstellen, müssen bereits in vitro eine Reihe an klinischen Anforderungen erfüllen. Hinsichtlich entsprechender Prüfverfahren wurde noch keine Normierungsarbeit geleistet, weswegen Ergebnisse verschiedener Arbeiten schwierig vergleichbar sind.
Ziel der Arbeit war es daher Prüfverfahren vorzustellen, welche die Besonderheiten des „Werkstoffes Knochen“ berücksichtigen. In diesem Rahmen werden zwei neuartigen Klebstoffsysteme, ein in situ härtender Knochenzement aus Trimagnesiumphosphat, Magnesiumoxid und organischer Phytinsäure und ein lichthärtender Knochenklebstoff aus Polyethylenglycoldimethacrylat, NCO-sP(EO-stat-PO), Campherchinon und anorganischen Newberyit-Füllern, vorgestellt. Neben diesen sind drei kommerziell erhältliche Klebstoffe Gegenstand der Untersuchung. Dies sind zum einen Histoacryl® und TruGlue® Gewebekleber, zwei Klebstoffe auf Cyanoacrylat-Basis mit unterschiedlich langer Alkyl-Seitenkette, zum anderen Bioglue®, ein Gewebekleber aus Albumin und Glutaraldehyd.
Bei den Klebstoffen wurde die Zug- und Scherfestigkeit unter Einfluss der physiologischen Klebstoffalterung, der Variation der Klebefugenbreite, der Variation von komplementären Fügeteilen, sowie Fügeteiloberflächen inspiziert. Makro- und mikroskopische, sowie elektronenmikroskopischen Untersuchung der Bruchflächen auf mikrostrukturelle Besonderheiten und Versagemechanismus wurden angestellt.
Die neuartigen Klebstoffsysteme unterliegen zwar den konventionellen Cyanoacrylaten hinsichtlich mechanischer Parameter, weisen aber dennoch adäquate Klebefestigkeiten auf bei zugleich zahlreichen Vorteilen gegenüber konventionellen Systemen im Umgang mit Knochen.
Gerade der Magnesiumphosphatzement scheint auf Grund mechanischer Parameter und Vorzügen wie der guten Biokompatibilität und biologischen Abbaubarkeit, Osteoinduktivität, Osteokonduktivität, der einfachen Applizierbarkeit, einem hohen Kosten-Nutzen-Faktor oder dem günstigen Verhalten in wässrigen Milieu vielversprechend.