Refine
Is part of the Bibliography
- yes (244)
Year of publication
Document Type
- Journal article (129)
- Doctoral Thesis (113)
- Other (1)
- Preprint (1)
Keywords
- MRI (22)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Kernspintomografie (8)
- Herzinfarkt (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (244) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
In der Nachsorge des Medulloblastoms wird standardmäßig auf die Bildgebung mittels Magnetresonanztomographie zurück gegriffen. Da die Erkrankung vor allem entlang der Liquorwege in Form einer kranialen oder spinalen Meningeose metastasiert, wurde anhand Daten der Therapieoptimierungsstudie "HIT 2000" verglichen, welche Lokalisation am häufigsten betroffen ist. Es zeigte sich, dass zu einem hohen Prozentanteil vor allem eine kombinierte Meningeose im Rezidiv oder Progress auftritt, gefolgt von einer kranialen Metastasierung. Dennoch gibt es eine Gruppe an Patienten, die eine isolierte spinale Meningeose entwickeln.
Acute ischemic cardiac injury predisposes one to cognitive impairment, dementia, and depression. Pathophysiologically, recent positron emission tomography data suggest astroglial activation after experimental myocardial infarction (MI). We analyzed peripheral surrogate markers of glial (and neuronal) damage serially within 12 months after the first ST-elevation MI (STEMI). Serum levels of glial fibrillary acidic protein (GFAP) and neurofilament light chain (NfL) were quantified using ultra-sensitive molecular immunoassays. Sufficient biomaterial was available from 45 STEMI patients (aged 28 to 78 years, median 56 years, 11% female). The median (quartiles) of GFAP was 63.8 (47.0, 89.9) pg/mL and of NfL 10.6 (7.2, 14.8) pg/mL at study entry 0–4 days after STEMI. GFAP after STEMI increased in the first 3 months, with a median change of +7.8 (0.4, 19.4) pg/mL (p = 0.007). It remained elevated without further relevant increases after 6 months (+11.7 (0.6, 23.5) pg/mL; p = 0.015), and 12 months (+10.3 (1.5, 22.7) pg/mL; p = 0.010) compared to the baseline. Larger relative infarction size was associated with a higher increase in GFAP (ρ = 0.41; p = 0.009). In contrast, NfL remained unaltered in the course of one year. Our findings support the idea of central nervous system involvement after MI, with GFAP as a potential peripheral biomarker of chronic glial damage as one pathophysiologic pathway.
Mapping the longitudinal relaxation time \(T_1\) has widespread applications in clinical MRI as it promises a quantitative comparison of tissue properties across subjects and scanners. Due to the long scan times of conventional methods, however, the use of quantitative MRI in clinical routine is still very limited. In this work, an acceleration of Inversion-Recovery Look-Locker (IR-LL) \(T_1\) mapping is presented. A model-based algorithm is used to iteratively enforce an exponential relaxation model to a highly undersampled radially acquired IR-LL dataset obtained after the application of a single global inversion pulse. Using the proposed technique, a \(T_1\) map of a single slice with 1.6mm in-plane resolution and 4mm slice thickness can be reconstructed from data acquired in only 6s. A time-consuming segmented IR experiment was used as gold standard for \(T_1\) mapping in this work. In the subsequent validation study, the model-based reconstruction of a single-inversion IR-LL dataset exhibited a \(T_1\) difference of less than 2.6% compared to the segmented IR-LL reference in a phantom consisting of vials with \(T_1\) values between 200ms and 3000ms. In vivo, the \(T_1\) difference was smaller than 5.5% in WM and GM of seven healthy volunteers. Additionally, the \(T_1\) values are comparable to standard literature values. Despite the high acceleration, all model-based reconstructions were of a visual quality comparable to fully sampled references. Finally, the reproducibility of the \(T_1\) mapping method was demonstrated in repeated acquisitions. In conclusion, the presented approach represents a promising way for fast and accurate \(T_1\) mapping using radial IR-LL acquisitions without the need of any segmentation.
In this work, a model-based acceleration of parameter mapping (MAP) for the determination of the tissue parameter T1 using magnetic resonance imaging (MRI) is introduced. The iterative reconstruction uses prior knowledge about the relaxation behavior of the longitudinal magnetization after a suitable magnetization preparation to generate a series of fully sampled k-spaces from a strongly undersampled acquisition. A Fourier transform results in a spatially resolved time course of the longitudinal relaxation process, or equivalently, a spatially resolved map of the longitudinal relaxation time T1.
In its fastest implementation, the MAP algorithm enables the reconstruction of a T1 map from a radial gradient echo dataset acquired within only a few seconds after magnetization preparation, while the acquisition time of conventional T1 mapping techniques typically lies in the range of a few minutes. After validation of the MAP algorithm for two different types of magnetization preparation (saturation recovery & inversion recovery), the developed algorithm was applied in different areas of preclinical and clinical MRI and possible advantages and disadvantages were evaluated.
Aims
To survey the perceived indications for magnetic resonance imaging of the small bowel (MRE) by experts, when MR enteroclysis (MREc) or MR enterography (MREg) may be chosen, and to determine how the approach to MRE is modified when general anaesthesia (GA) is required.
Materials and methods
Selected opinion leaders in MRE completed a questionnaire that included clinical indications (MREg or MREc), specifics regarding administration of enteral contrast, and how the technique is altered to accommodate GA.
Results
Fourteen responded. Only the diagnosis and follow-up of Crohn’s disease were considered by over 80 % as a valid MRE indication. The remaining indications ranged between 35.7 % for diagnosis of caeliac disease and unknown sources of gastrointestinal bleeding to 78.6 % for motility disorders. The majority chose MREg over MREc for all indications (from 100 % for follow-up of caeliac disease to 57.7 % for tumour diagnosis). Fifty per cent of responders had needed to consider MRE under GA. The most commonly recommended procedural change was MRI without enteral distention. Three had experience with intubation under GA (MREc modification).
Conclusion
Views were variable. Requests for MRE under GA are not uncommon. Presently most opinion leaders suggest standard abdominal MRI when GA is required.
Die 31P-MRS wird zur Diagnostik des Energiemetabolismus bei verschiedenen kardialen Erkrankungen eingesetzt. Die vorliegende Arbeit befasst sich mit einer Verbesserung und Vereinfachung der Quantifzierung kardialer Energiemetaboliten mittels der 31P-MRS. Durch Akquisitonsgewichtung kann eine genauere Beurteilung der Konzentrationen von PCr und ATP im gesunden Myokard durch Verbesserung der Effizienz und Sensitivität der 31P-MRS erreicht werden. Die Kontamination des MR-Signals durch die Brustwand wird mittels des CORRECT-SLIM-Algorithmus verringert. Eine Fallstudie am rechten Ventrikel zeigt die starke metabolische Aussagekraft der 31P-MRS vor, während und nach medikamentöser Therapie. Die 31P-MRS unter Verwendung räumlicher Sättigungspulse liefert einen unmittelbaren Einblick in den Energiemetabolismus des menschlichen Herzens mit einer deutlich kürzen Nachbearbeitungszeit. Durch diese Optimierungen ermöglicht die 31P-MRS des menschlichen Herzens eine exakte Beurteilung des Energiemetabolismus im gesunden wie erkrankten Myokard.
Background
Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI.
Methods
49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated.
Results
Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PD\(_{outflow}\)/PD\(_{inflow}\) increased by 65% (p < 0.001) and AUC\(_{outflow}\)/AUC\(_{inflow}\) increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05).
Conclusions
Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.
In der vorliegenden Arbeit wurde untersucht, ob die farbige DSA-Darstellungsweise besser als die monochromatische dazu geeignet ist, eine Entscheidung über eine mögliche Stentimplantation bei pAVK zu treffen.
Hierfür wurden DSA-Daten des Universitätsklinikums Würzburg im Zeitraum 04/2014 - 10/2015 retrospektiv ausgewertet. Drei Ärzte bewerteten die Bilder in zwei getrennten Durchgängen bezüglich ihrer Entscheidung zur Stentimplantation. Diese Entscheidungen wurden mit einem Konsensus aus 2 Ärzten verglichen. Anhand von ROC-Analysen konnte so die Treffsicherheit der Entscheidungen evaluiert werden.
In der Studie stellte sich die farbkodierte Darstellung im Vergleich zur monochromatischen Darstellung nicht als überlegen heraus.
Purpose:
The gradient system transfer function (GSTF) characterizes the frequency transfer behavior of a dynamic gradient system and can be used to correct non‐Cartesian k‐space trajectories. This study analyzes the impact of the gradient coil temperature of a 3T scanner on the GSTF.
Methods:
GSTF self‐ and B\(_0\)‐cross‐terms were acquired for a 3T Siemens scanner (Siemens Healthcare, Erlangen, Germany) using a phantom‐based measurement technique. The GSTF terms were measured for various temperature states up to 45°C. The gradient coil temperatures were measured continuously utilizing 12 temperature sensors which are integrated by the vendor. Different modeling approaches were applied and compared.
Results:
The self‐terms depend linearly on temperature, whereas the B0‐cross‐term does not. Effects induced by thermal variation are negligible for the phase response. The self‐terms are best represented by a linear model including the three gradient coil sensors that showed the maximum temperature dependence for the three axes. The use of time derivatives of the temperature did not lead to an improvement of the model. The B\(_0\)‐cross‐terms can be modeled by a convolution model which considers coil‐specific heat transportation.
Conclusion:
The temperature dependency of the GSTF was analyzed for a 3T Siemens scanner. The self‐ and B0‐cross‐terms can be modeled using a linear and convolution modeling approach based on the three main temperature sensor elements.
Der Morbus Fabry ist eine lysosomale Speicherkrankheit, die auf einem Mangel des Enzyms a-Galaktosidase A beruht. Die Krankheit wird X-chromosomal rezessiv vererbt und entsteht durch Mutation des a-Galaktosidase-Gens auf dem langen Arm des Chromosoms Xq22. Durch die erniedrigte bzw. fehlende Enzymaktivität kommt es zu einer übermäßigen Ablagerung von Glykosphingolipiden in sämtlichen Geweben des menschlichen Körpers, besonders betroffen sind Herz, Nieren, Gefäße und ZNS. Die Krankheit ist durch einen progredienten Verlauf und einer eingeschränkten Lebenserwartung gekennzeichnet. Insbesondere die kardialen Auswirkungen wie Herzrhythmusstörungen, Klappenvitien und linksventrikuläre Hypertrophie führen zur Herzinsuffizienz und fast immer zu einem meist frühzeitigen Tod durch Herzversagen. Seit einiger Zeit steht in der Enzymersatztherapie mit rekombinanter a-Galaktosidase A (Agalsidase) eine kausale Behandlung zur Verfügung. Unter der Therapie mit Agalsidase zeigen sich auch Verbesserungen der kardialen Parameter, insbesondere eine Reduktion der linksventrikulären Masse. Zur Kontrolle und zur Dokumentation der medikamentösen Wirkung an den verschiedenen Organen waren und sind klinische Studien und Untersuchungen der betroffenen Patienten notwendig. Zur Beurteilung der kardialen Funktion steht, neben den bekannten Routineverfahren wie der Echokardiographie und der MR-Bildgebung, mit der 31P-Magnetresonanz-Spektroskopie ein nicht invasives Verfahren zur Beurteilung des myokardialen Stoffwechsels zur Verfügung. Mit Hilfe von speziellen Auswerteprogrammen können die Absolutkonzentrationen von energiereichen Metaboliten, besonders von Phosphokreatin und Adenosintriphosphat, im Herzmuskel in vivo bestimmt werden. Ziel der vorliegenden Arbeit war zunächst einmal die Messung der Konzentrationen der energiereichen Metabolite im Myokard von Patienten mit Morbus Fabry und der Vergleich der Daten mit denen von gesunden Probanden. Des weiteren wurde die Patientengruppe unter Therapie mit Agalsidase b einer frühen und einer späten Kontrolluntersuchung mittels MR-Spektroskopie unterzogen, um Veränderungen im kardialen Metabolismus darzustellen. Die spektroskopischen Daten gaben Aufschluss über Ausmaß der Beeinträchtigung des myokardialen Stoffwechsels aufgrund der Gb3-Ablagerungen und ergänzten die klinischen und bildmorphologischen Untersuchungen. Hierbei konnte eine tendenzieller Anstieg der PCr- und ATP-Konzentrationen unter ERT im Myokard nachgewiesen werden, gleichfalls zeigten sich in dem untersuchten Kollektiv eine Abnahme der linksventrikulären Masse und eine erhöhte Ejektionsfraktion. Ebenso konnte dargelegt werden, dass wie auch bei anderen Herzerkrankungen, wie zum Beispiel der dilatativen Kardiomyopathie oder der koronaren Herzkrankheit, bei einer Stoffwechselerkrankung wie der Fabry-Krankheit deutlich verringerte Konzentrationen energiereicher Phosphate in den Herzmuskelzellen vorliegen.
Die akute Extremitätenischämie ist ein klinischer Notfall, der in Abhängigkeit der Dauer und der Ausprägung klinischer Symptome interventionell und chirurgisch behandelt werden kann. Ziel dieser Studie war es, den klinischen und technischen Erfolg der primären interventionellen Therapie der akuten Extremitätenischämie zu untersuchen und die Bedeutung der Anwendung und Kombination primär nicht-thrombolytischer Verfahren zu eruieren. Als zusätzliche Zielparameter wurden die Mortalitätsrate, die Komplikationsrate, das amputationsfreie Überleben sowie das reischämiefreie Intervall evaluiert.
Im Rahmen unserer Studie wurden 165 Patienten (89 männlich: 53,9%, 76 weiblich: 46,1%, Altersmittelwert: 77,5 Jahre, STABW ± 13,1 Jahre) und 167 Extremitäten (links n = 84, rechts n = 83) retrospektiv untersucht. Während der stationären Aufnahme wurden das Verschlussalter ermittelt (perakut bis chronisch), die Art des Verschlusses (komplett vs. inkomplett), die Lokalisation und Genese des Verschlusses sowie die Risikofaktoren der Patienten. Der technische Erfolg wurde radiologisch mithilfe des TIMI-Scores erhoben, der klinische Erfolg wurde während des stationären Aufenthalts und im Rahmen des Follow-ups beurteilt.
Die Mehrheit der Verschlüsse (60,5 %, n = 101) war weniger als 7 Tage alt und präsentierte sich klinisch als eine inkomplette Ischämie (n = 147, 88%). Die Okklusion reichte in 63,5 % nicht über das POP II Segment hinaus. Ursächlich war bei n = 107 der 167 Extremitäten (64,1 %) ein „akut auf chronischer“ Verschluss bei vorbestehender pAVK, in n = 41 Fällen eine Thrombembolie (24,6 %) und in n = 19 Extremitäten eine arterielle Thrombose (11,4 %).
Bei allen behandelten Extremitäten handelte es sich um einen primären Eingriff, der mittels perkutaner mechanischer Rotationsthrombektomie durchgeführt wurde. Dieser wurde bei n = 152 Verschlüssen (91 %) mit anderen (nicht thrombolytischen) interventionellen Verfahren kombiniert. Dabei wurden n = 66 Verschlüsse (39,5 %) mit einer mehrfachen Kombination aus PTA, Stent und/oder konventioneller PAT behandelt. Bei weiteren n = 43 Interventionen (25,7 %) reichte eine alleinige zusätzliche Stentimplantation aus, bzw. bei n = 33 Okklusionen (19,8 %) eine alleinige zusätzliche PTA. Lediglich in n = 15 Fällen (9 %) wurde die PMT ohne additive endovaskuläre Verfahren durchgeführt.
Wir konnten in 92,2 % der Fälle (n = 154 Eingriffen) einen primären technischen und auch klinischen Erfolg beobachten. Insgesamt lag die reischämie-/reinterventionsfreie Rate nach 30 Tagen bei 86,2 %. Die reischämie-/reinterventionsfreie Rate betrug nach 6, 12, 24 und 36 Monaten jeweils 75,6%, 69,7%, 67,1% und respektive 64,4%. Die Amputationsrate betrug nach 30 Tagen 6,3 %, nach 6 Monaten 9 % und nach einem Jahr 11,2 %. Insgesamt verstarben n = 76 von den initial 165 Patienten (46,1 %) innerhalb des Nachbeobachtungs-zeitraums von 31,8 Monaten (STABW ± 24 Monate). Nach 30 Tagen lag das Gesamtüberleben bei 91 %, nach 6 Monaten bei 83,8 % und nach einem Jahr bei 77,2 %. Drei Patienten verstarben innerhalb der ersten 24 Stunden nach dem Eingriff, was entweder auf die Intervention oder die Kontrastmittel- und Volumenbelastung zurückzuführen war und als F-Komplikation zu werten ist.
In 4,2 % der Fälle (n = 7) konnte die akute Extremitätenischämie nicht suffizient endovaskulär behandelt werden. Bei n = 6 Eingriffen (3,6 %) kam es zu Minorkomplikationen und in n = 8 weiteren Fällen zu Majorkomplikationen. Darunter waren die häufigsten Komplikationen das Kompartmentsyndrom (n = 4, 2,4 %) und die distale Embolisation (n = 4, 2,4 %) ohne anschließende Möglichkeit der erfolgreichen Thrombusbergung. Alle anderen n = 146 Eingriffe (87,4 %) verliefen komplikationslos.
We report on a currently 76-year-old female patient with relapsed/refractory (RR) multiple myeloma (MM) treated at our institution. This patient had received six lines of therapy including tandem autologous stem cell transplant, proteasome inhibitor, immunomodulatory drugs and CD38 antibody MOR202. At the last relapse, she progressed during treatment with pomalidomide and MOR202. In an individualized therapy concept, we started a multi-agent salvage therapy with pomalidomide, bortezomib, doxorubicin, dexamethasone, and CD38 antibody daratumumab (“Pom-PAD-Dara”), which resulted in a stringent complete remission with minimal residual disease (MRD) negativity after nine cycles. So far, our patient shows a progression free survival of more than 12 months. Our case demonstrates the feasibility of successful CD38 antibody retreatment in a patient with heavily pretreated CD38 antibody resistant MM.
Background
Progressive multifocal leukoencephalopathy is a demyelinating CNS disorder. Reactivation of John Cunningham virus leads to oligodendrocyte infection with lysis and consequent axonal loss due to demyelination. Patients usually present with confusion and seizures. Late diagnosis and lack of adequate therapy options persistently result in permanent impairment of brain functions. Due to profound T cell depletion, impairment of T-cell function and potent immunosuppressive factors, allogeneic hematopoietic cell transplantation recipients are at high risk for JCV reactivation. To date, PML is almost universally fatal when occurring after allo-HCT.
Methods
To optimize therapy specificity, we enriched JCV specific T-cells out of the donor T-cell repertoire from the HLA-identical, anti-JCV-antibody positive family stem cell donor by unstimulated peripheral apheresis [1]. For this, we selected T cells responsive to five JCV peptide libraries via the Cytokine Capture System technology. It enables the enrichment of JCV specific T cells via identification of stimulus-induced interferon gamma secretion.
Results
Despite low frequencies of responsive T cells, we succeeded in generating a product containing 20 000 JCV reactive T cells ready for patient infusion. The adoptive cell transfer was performed without complication. Consequently, the clinical course stabilized and the patient slowly went into remission of PML with JCV negative CSF and containment of PML lesion expansion.
Conclusion
We report for the first time feasibility of generating T cells with possible anti-JCV activity from a seropositive family donor, a variation of virus specific T-cell therapies suitable for the post allo transplant setting. We also present the unusual case for successful treatment of PML after allo-HCT via virus specific T-cell therapy.
Das Ziel der Studie bestand darin, die Durchführbarkeit, Effizienz und Sicherheit der perkutanen transluminalen Zangenbiopsie bei biliären Strikturen nach „Cross and push“ Technik am Universitätsklinikum Würzburg zu evaluieren.
Die Gewinnung der Zangenbiopsie bei den insgesamt 17 Patienten erfolgte an den baugleichen Angiographieeinheiten der interventionellen radiologischen Abteilung.
Die Schaffung des biliären Zugangsweges wurde per Feinnadelpunktion oder über einen bereits einliegenden Drainagekatheter durchgeführt. Nach Vordirigieren einer armierten Führungsschleuse bis unmittelbar vor die Stenose wurden die Gewebeproben mittels Biopsiezange entnommen. Auf diese Weise sollte ein Abknicken des Instrumentariums durch die fibrotische Beschaffenheit der Striktur vermieden und so die Gewebegewinnung erleichtert werden. Im Anschluss folgten die PTCD-Neuanlage bzw. der Katheterwechsel sowie die histologische Auswertung der Zangenbiopsie. Die Dokumentation umfasste den technischen Erfolg, die Biopsieanzahl sowie -größe, die Untersuchungs- und die Fluoroskopiezeit, das Dosisflächenprodukt, die Repräsentativität der Biopsien und die Komplikationsrate.
Die technische Erfolgsrate lag bei 100 %. Bei zehn Patienten und Patientinnen (58,8 %) wurde in der Zangenbiopsie ein Malignom bestätigt. Bei sieben Betroffenen (41,2 %) ergab die Zangenbiopsie einen benignen Befund, wobei dieser in zwei Fällen (11,8 %) falsch negativ war. Die Kriterien der Repräsentativität wurden bei elf Patienten und Patientinnen (64,7 %) erfüllt. Die mediane Biopsiezahl betrug 4 und die Biopsiegröße war 1 - 2 mm. Bei einer medianen Untersuchungszeit von 24 min bemaß sich die mediane Fluoroskopiezeit auf 7,6 min. Das mediane DAP für alle Interventionen betrug 2.593 μGym2. Zu einer Majorkomplikation kam es bei einer Patientin (5,9 %).
Bei der perkutanen transluminalen Zangenbiopsie nach „Cross and push“ Technik handelt es sich um ein effektives und sicheres Verfahren zur histologischen Beurteilung biliärer Strikturen mit einer moderaten Komplikationsrate. Die Anwendung sollte besonders bei proximalen Strikturen in Betracht gezogen werden, wenn die ERCP oder alternative Verfahren nicht erfolgreich waren und parallel eine Entlastung der Cholestase via PTCD intendiert oder bereits vorhanden ist. Zur weiteren Evaluation der Methode ist zukünftig die Betrachtung eines größeren Patientenkollektives nötig. Um das Verfahren mit Alternativmethoden vergleichen zu können, bedarf es randomisierter kontrollierter Studien.
Retrospektive Studie (1995-1999) aus dem Institut für Röntgendiagnostik der Universität Würzburg mit insgesamt 206 Patienten. Die Offenheitsraten der insg. 535 radiologischen Interventionen (PTA, Stentimplantationen) der Becken- und Beinarterien wurden in einer statistischen Auswertung nach Kaplan-Meier dargestellt. Dabei wurden die Ergebnisse auf die unterschiedlichen Grundparameter (Alter, Geschlecht, Risikofaktoren, Fontaine-Stadium, Gefäßlokalisation, Runoff, Stenosenart, Stenosenanzahl, Interventionsart...) bezogen.
In den letzten Jahren wird verbreitet das Coiling, die endovaskuläre Technik zur Behandlung von intrakraniellen Aneurysmata genutzt. Hierbei werden mittels eines Mikrokatheters Platinspiralen unter Durchleuchtung in das Aneurysma platziert. Aufgrund dieser minimal invasiven Methode und positiver Ergebnisse in verschiedenen Studien ist es heute eine Alternative zum bisherigen chirurgischen Clipping, das immer mehr in den Hintergrund gedrängt wurde. In der vorliegenden Studie wird die Rate der periinterventionellen Komplikationen (wie Coildislokationen und Gefäßverschlüsse), der Zusammenhang zwischen der Rekanalisation und der Aneurysmagröße, der Packungsdichte, der verwendeten Spiralen, sowie der Lokalisation des Aneurysmas untersucht. Ziel ist es das Verhältnis der Okklusion des Aneurysmas zu den oben genannten Faktoren zu klären. Im retrospektiven Teil der Studie werden Aneurysmen von 198 Patienten und im prospektiven Anteil 100 Patienten mit 101 Aneurysmen eingeschlossen. Im Anschluss werden die Ergebnisse mit ähnlichen oder vergleichbaren Daten der Literatur, wie z. B. die ISAT und deren Folgestudien, diskutiert. Ein direkter Vergleich war nicht möglich, da diese Studien weitaus größere Patientenanzahlen beinhalteten.
MRT-Untersuchungen des Herzens haben in den letzten Jahren an Häufigkeit und Bedeutung zugenommen. Die Nachfrage nach schnelleren und für den Patienten komfortableren Sequenzen steigt. Diese Arbeit untersucht, ob es mit Hilfe von parallelen Echtzeitsequenzen ohne EKG-Triggerung möglich ist, die Untersuchungszeit deutlich zu verkürzen und dabei gut reproduzierbare Messwerte zu erhalten. Hierzu wurden 9 Probanden und 21 Patienten mit A) paralleler Echtzeitbildgebung bei freier Atmung und B)einer Standard CINE Sequenz mit Atemstopp untersucht. Zur statistischen Analyse beider Methoden dienten Bland-Altman-Plots. Um Aussagen über die Reproduzierbarkeit der Ergebnisse treffen zu können wurde außerdem die Variabilität der Messungen bestimmt. Die Messzeit der neuen Echtzeitsequenz war um mehr als das zehnfache kürzer als die einer herkömmlichen CINE Sequenz. Die Ergebnisse waren mit der Standard CINE Sequenz vergleichbar und zeigten nur einen geringe Variabilität. Lediglich die linksventrikuläre Masse wurde im Gesamtkollektiv leicht überschätzt. Insgesamt scheint die Echtzeitbildgebung aufgrund der zuverlässigen Ergebnisse für den Klinikalltag geeignet. Insbesondere Patienten mit Atemnot, Herzrhythmusstörungen oder aber Kinder könnten profitieren.
Die Zielsetzung dieser Arbeit ist, die Möglichkeiten der Magnetresonanz Spektroskopie zur nichtinvasiven Diagnostik des Myokardstoffwechsels bei globalen Herzkrankheiten unter Verwendung neuer Möglichkeiten der Absolutquantifizierung von hochenergetischen Phosphaten zu beschreiben. Im Vordergrund dieser Arbeit stehen folgende Punkte: 1. Etablierung einer Methode zur Absolutquantifizierung von Metabolitenkonzentrationen aus dem menschlichen Myokard und Festlegung eines standardisierten Untersuchungsprotokolls 2. Überprüfung der Methode auf Variabilitäten durch Mehrfachauswertungen und Verlaufsuntersuchungen 3. Untersuchung der Altersabhängigkeit der Metabolitenkonzentrationen 4. Einsatz der Methode an Patienten mit globalen Herzerkrankungen; Herausstellung der metabolischen Unterschiede bei Hypertrophie und Dilatation.
Bone marrow lesions (BML) represent areas of deteriorated bone structure and metabolism characterized by pronounced water‐equivalent signaling within the trabecular bone on magnetic resonance imaging (MRI). BML are associated with repair mechanisms subsequent to various clinical conditions associated with inflammatory and non‐inflammatory injury to the bone. There is no approved treatment for this condition. Bisphosphonates are known to improve bone stability in osteoporosis and other bone disorders and have been used off‐label to treat BML. A randomized, triple‐blind, placebo‐controlled phase III trial was conducted to assess efficacy and safety of single‐dose zoledronic acid (ZOL) 5 mg iv with vitamin D 1000 IU/d as opposed to placebo with vitamin D 1000 IU/d in 48 patients (randomized 2:1) with BML. Primary efficacy endpoint was reduction of edema volume 6 weeks after treatment as assessed by MRI. After treatment, mean BML volume decreased by 64.53% (±41.92%) in patients receiving zoledronic acid and increased by 14.43% (±150.46%) in the placebo group (p = 0.007). A decrease in BML volume was observed in 76.5% of patients receiving ZOL and in 50% of the patients receiving placebo. Pain level (visual analogue scale [VAS]) and all categories of the pain disability index (PDI) improved with ZOL versus placebo after 6 weeks but reconciled after 6 additional weeks of follow‐up. Six serious adverse events occurred in 5 patients, none of which were classified as related to the study drug. No cases of osteonecrosis or fractures occurred. Therefore, single‐dose zoledronic acid 5 mg iv together with vitamin D may enhance resolution of bone marrow lesions over 6 weeks along with reduction of pain compared with vitamin D supplementation only.
Die Arbeit befasst sich mit der Frage, welche Bedeutung die Radiologie in ihrer Anfangszeit (1895-1912) für die Verselbstständigung der Kinderheilkunde zur eigenen klinischen Disziplin hatte. Sie verdeutlicht dies anhand ausgewählter Krankheitsbilder bei denen die Radiologie neue Erkenntnisse erbrachte, eine frühere und beweiskräftigere Diagnose ermöglichte, eine effektivere Therapie zuließ oder auch ein verstärktes Interesse an den medizinischen Besonderheiten des Kindesalters weckte. In diesem Zusammenhang werden auch Ergebnisse der entsprechenden Grundlagenforschung dargestellt, wie zum Beispiel die Ossifikationsstudien. Insgesamt werden, basierend auf konkreten Beispielen, Zusammenhänge zwischen radiologischer Forschung und der Forderung nach Verselbstständigung der Kinderheilkunde als eigenständige Disziplin hergestellt.
Die 31-P-Magnetresonanz-Spektroskopie (31-P-MRS) ist eine nicht-invasive Methode, welche einen direkten Einblick in den Phospholipid-Haushalt der menschlichen Leber erlaubt. Mit der 31-P-MR-Spektroskopie wurden Spektren von 10 Patienten mit Leberzirrhose sowie von 13 gesunden Probanden in Kombination mit dem Lokalisationsverfahren 3D-CSI und dem Nachbearbeitungsprogramm SLOOP (Spectral Localization with Optimal Pointspread Funktion) gewonnen. Die Ergebnisse dieser Studie ergaben signifikante Unterschiede in den Absolutkonzentrationen der Phospholipide zwischen Patienten mit Leberzirrhose und lebergesunden Probanden.
Ultra-high field cardiac MRI in large animals and humans for translational cardiovascular research
(2023)
A key step in translational cardiovascular research is the use of large animal models to better understand normal and abnormal physiology, to test drugs or interventions, or to perform studies which would be considered unethical in human subjects. Ultrahigh field magnetic resonance imaging (UHF-MRI) at 7 T field strength is becoming increasingly available for imaging of the heart and, when compared to clinically established field strengths, promises better image quality and image information content, more precise functional analysis, potentially new image contrasts, and as all in-vivo imaging techniques, a reduction of the number of animals per study because of the possibility to scan every animal repeatedly. We present here a solution to the dual use problem of whole-body UHF-MRI systems, which are typically installed in clinical environments, to both UHF-MRI in large animals and humans. Moreover, we provide evidence that in such a research infrastructure UHF-MRI, and ideally combined with a standard small-bore UHF-MRI system, can contribute to a variety of spatial scales in translational cardiovascular research: from cardiac organoids, Zebra fish and rodent hearts to large animal models such as pigs and humans. We present pilot data from serial CINE, late gadolinium enhancement, and susceptibility weighted UHF-MRI in a myocardial infarction model over eight weeks. In 14 pigs which were delivered from a breeding facility in a national SARS-CoV-2 hotspot, we found no infection in the incoming pigs. Human scanning using CINE and phase contrast flow measurements provided good image quality of the left and right ventricle. Agreement of functional analysis between CINE and phase contrast MRI was excellent. MRI in arrested hearts or excised vascular tissue for MRI-based histologic imaging, structural imaging of myofiber and vascular smooth muscle cell architecture using high-resolution diffusion tensor imaging, and UHF-MRI for monitoring free radicals as a surrogate for MRI of reactive oxygen species in studies of oxidative stress are demonstrated. We conclude that UHF-MRI has the potential to become an important precision imaging modality in translational cardiovascular research.
ZIEL: Die Miktionsurosonographie (MUS) entwickelte sich zu einer alternativen Untersuchungsmethode gegenüber der Miktionszystourethrographie (MCU) in der Diagnostik des vesikoureteralen Refluxes (VUR). Neuentwickelte stabile US-Kontrastmittel führen zu einer Dosis- und Kostenreduktion der MUS, Harmonic Imaging erhöht die Stabilität der US-Kontrastmittel. Diese Studie vergleicht die kontrastverstärkte sonographische Diagnostik des VUR unter Einsatz eines US-Kontrastmittels der 2. Generation [SonoVue®] mit der MCU. Zudem erfolgt ein Vergleich der Ultraschallmodalitäten Fundamental (F), Tissue Harmonic Imaging (THI) und Echo Contrast Imaging (ECI) bezüglich der Darstellbarkeit der Mikrobläschen des US-Kontrastmittels. MATERIAL und METHODEN: Es wurden 40 Patienten mit insgesamt 84 Nieren-Ureter-Einheiten (NUE) untersucht. Zunächst wurde die MUS und anschließend die MCU durchgeführt. Bei der MUS wurde zwischen den 3 Ultraschallmodalitäten F, THI und ECI gewechselt. Der mechanische Index (MI) wurde automatisch jeder Ultraschallmodalität angepasst. Als US-Kontrastmittel wurde SonoVue® eingesetzt, die Dosis betrug 1% des Blasenfüllungsvolumens. MUS und MCU wurden hinsichtlich der Detektionsrate des VUR verglichen. Beim Vergleich von F, THI und ECI wurden ein Ranking und ein Scoring durchgeführt. ERGEBNISSE: Es lag bei 11 Patienten in beiden Untersuchungen ein VUR vor, bei jeweils 3 Patienten konnte nur in einer der beiden Methoden ein Reflux diagnostiziert werden. Beim Vergleich der MUS mit der Standardmethode MCU zeigten sich eine Sensitivität von 85%, eine Spezifität von 92,2%, ein positiver Vorhersagewert (PVW) von 77,3% und ein negativer Vorhersagewert (NVW) von 95,2%. Beim Vergleich von F, THI und ECI zeigte sich ein signifikanter Vorteil von ECI gegenüber F, nicht aber gegenüber THI. Zwischen THI und F gab es keinen signifikanten Unterschied in der Darstellung der Mikrobläschen. SCHLUSSFOLGERUNG: Der Einsatz eines US-Kontrastmittels der 2. Generation (SonoVue®) in der MUS erzielt vergleichbare Ergebnisse in der Diagnostik des VUR wie die MCU. Die Dosisreduktion (1% des Blasenfüllungsvolumens) könnte zu einer Verringerung der Kosten einer MUS führen. Das Harmonic Imaging ermöglicht eine bessere Darstellung der Mikrobläschen im Vergleich zur fundamentalen Bildgebung.
Evaluation von Defekten des triangulären fibrokartilaginären Komplexes (TFCC) und der intrinsischen Bänder des Handgelenkes mit der direkten MR-Arthrographie im Vergleich zur diagnostischen Arthroskopie unter besonderer Berücksichtigung von Partialdefekten. Material und Methoden: 75 direkte MR-Arthrographien des Handgelenkes (intraartikuläre Injektion eines Gemisches aus Gadoliniumchelaten und Iotrolan) wurden von zwei erfahrenen Radiologen im Konsens ausgewertet. Es wurden T1-gewichtete Spin-Echo(SE)-Sequenzen in frontaler und sagittaler sowie Fast low angle shot (FLASH) 3D-Sequenzen in frontaler Schichtung akquiriert. Läsionen des skapholunären Bandes wurden entsprechend den Leitlinien der Deutschen Gesellschaft für Handchirurgie (DGH), Läsionen des lunatotriquetralen Bandes nach Hempfling, Läsionen des TFCC nach Palmer eingeteilt. Anschließend wurden die Befunde mit der Arthroskopie als Referenzstandard korreliert. Ergebnisse: Für die Verletzungen der intrinsischen Bänder und des TFCC waren die Sensitivitäten und Spezifitäten für Komplettrupturen 96% und 99,6% (T1-SE) bzw. 92% und 100% (FLASH 3D), für Partialdefekte 68,1% und 93,3% (T1-SE) bzw. 63% und 96,1% (FLASH 3D). Die T1-SE-Sequenz eignete sich für die Einschätzung skapholunärer Banddefekte besser als die FLASH 3D-Sequenz (p < 0,05). Für Partialdefekte das skapholunären Bandes wurde mit der T1-SE-Sequenz eine Sensitivität von 83,3%, mit der FLASH 3D-Sequenz von 64,7% erreicht. Schlussfolgerung: Die direkte MR-Arthrographie ist bei der Einschätzung von Komplettrupturen der intrinsischen Bänder und des TFCC der diagnostischen Arthroskopie gleichwertig. Mit der T1-SE-Sequenz sind Partialdefekte des skapholunären Bandes im Vergleich zur Arthroskopie mit ausreichender Sicherheit erkennbar. Die T1-SE-Sequenz war hierfür der FLASH 3D-Sequenz überlegen (p < 0,05) und sollte bei der Einschätzung skapholunärer Partialdefekte bevorzugt werden. Die Einschätzung des lunatotriquetralen Bandes gelingt nicht zuverlässig.
Bei Patienten mit Morbus Fabry spielt die kardiale MRT eine wesentliche Rolle für die Diagnostik, die Prognose und das Therapiemonitoring. Als Verfahren der Wahl zur Beurteilung einer fokalen myokardialen Fibrose hat sich das Late Gadolinium Enhancement (LGE) etabliert. Eine diffuse myokardiale Fibrosierung kann mittels LGE-Technik nicht suffizient abgebildet werden, da keine ausreichenden Unterschiede in der Signalintensität bestehen.
Daher könnte das sog. post-KM T1-Mapping eine interessante Alternative sein. Bei diesem Verfahren lassen die T1-Relaxationszeiten Rückschlüsse auf diffuse fibrotische Veränderungen des Myokards zu.
In der vorliegenden Arbeit wurden 43 Fabry-Patienten (20 LGE-positiv und 23 LGE-negativ) im MRT untersucht. Hierzu wurde eine modifizierte Look-Locker Inversion-Recovery (MOLLI)-Sequenz zur Messung der T1-Maps verwendet.
Ziel war es, durch das T1-Mapping Risikopatienten (u.a. LGE-negative Patienten) früher als bisher zu identifizieren und damit zeitnah einer entsprechenden Therapie zuzuführen.
Die Ergebnisse zeigten, dass LGE-positive Fabry-Patienten eine fortgeschrittenere diffuse Myokardfibrose im visuell gesunden Myokard aufweisen als LGE-negative Patienten. Eine Unterscheidung anhand der T1-Zeiten zwischen LGE-negativen Patienten und gesunden Probanden war nicht möglich. Somit kann das T1-Mapping nicht als diagnostische Methode zur Früherkennung einer diffusen Myokardfibrose bei Fabry-Patienten eingesetzt werden.
Des Weiteren konnte gezeigt werden, dass die T1-Zeit im linksventrikulären Myokard bei Fabry-Patienten mit eingeschränkter Nierenfunktion kürzer war als bei Patienten mit normaler Nierenfunktion, unabhängig vom Vorliegen einer fokalen Fibrose. Hingegen konnte im linksventrikulären Blut bei abnehmender glomerulärer Filtrationsrate (GFR) keine kürzere T1-Zeit festgestellt werden als bei normaler GFR.
Außerdem waren die T1-Relaxationszeiten bei LGE-negativen, weiblichen Fabry-Patienten kürzer als bei männlichen Patienten ohne LGE. Eine abschließende Erklärung konnte hierfür nicht gefunden werden.
T1-Mapping wird bislang noch nicht in der Routinediagnostik bei Morbus Fabry eingesetzt. Allerdings steigt dessen Bedeutung im Rahmen von Studien. Weitere Forschungsbemühungen sind notwendig, um geeignete Referenzwerte festzulegen und den Einfluss weiterer Faktoren auf die Fibrosierung des Myokards besser einschätzen zu können.
Objective
Multipartite epicondyles may mimic fractures in the setting of pediatric elbow trauma. This study examines the prevalence of multipartite epicondyles during skeletal development and their association with pediatric elbow fractures.
Materials and methods
In this retrospective analysis, 4282 elbow radiographs of 1265 elbows of 1210 patients aged 0–17 years were reviewed. The radiographs were analyzed by two radiologists in consensus reading, and the number of visible portions of the medial and lateral epicondyles was noted. For elbows in which epicondylar ossification was not yet visible, the epicondyles were already fused with the humerus or could not be sufficiently evaluated due to projection issues or because osteosynthesis material was excluded. In total, 187 elbows were included for the lateral and 715 for the medial epicondyle analyses.
Results
No multipartite medial epicondyles were found in patients without history of elbow fracture, whereas 9% of these patients had multipartite lateral epicondyles (p < 0.01). Current or previous elbow fractures increased the prevalence of multipartite epicondyles, with significant lateral predominance (medial epicondyle + 9% vs. lateral + 24%, p < 0.0001). Including all patients regardless of a history of elbow fracture, multipartite medial epicondyles were observed in 3% and multipartite lateral epicondyles in 18% (p < 0.0001). There was no gender difference in the prevalence of multipartition of either epicondyle, regardless of a trauma history.
Conclusion
Multipartite medial epicondyles occur in patients with current or previous elbow fractures only, whereas multipartite lateral epicondyles may be constitutional. Elbow fractures increase the prevalence of multipartite epicondyles on both sides, with significant lateral predominance.
Key Points
• Multipartite medial epicondyles should be considered of traumatic origin.
• Multipartite lateral epicondyles may be constitutional.
• Elbow fractures increase the prevalence of multipartite epicondyles on both sides with lateral predominance.
Es wurde die diagnostische Genauigkeit fünf verschiedener Rekonstruktionsalgorithmen der DE-CTA der Becken-Bein-Gefäße von Patienten mit pAVK an einem Dual-Source CT mit dem diagnostischen Goldstandard der DSA verglichen. Die DE-CTA zeigte eine exzellente Sensitivität an Becken- und Beingefäßen hinsichtlich einer korrekten Stenosegraduierung, unabhängig von der Rekonstruktion. Die Standard MPR zeigte insgesamt die besten Ergebnisse und ist deshalb vor allem in nicht eindeutigen Fällen die Methode der Wahl. Die Auswertung von DE-CS MPRs, DE-CS MIPs, gekrümmten MPRs oder die semi-automatische quantitative Stenosegradauswertung bringt keinen Zugewinn an diagnostischer Performance im Vergleich zur visuellen Auswertung der Standard MPR. Das Ausmaß der Gefäßwandverkalkungen und die intraluminale Kontrastierung hatten keinen signifikanten Effekt auf die Sensitivität zur Erkennung signifikanter Stenosen an den Becken- und Beingefäßen. Jedoch verschlechterten sich die Spezifität und die Genauigkeit der Rekonstruktionen, welche auf der DE-Knochen- und DE-Plaqueentfernung basieren, signifikant in stark verkalkten oder nur schwach kontrastierten Gefäßsegmenten. Beim Auswerten von DE-CS Rekonstruktionen ist infolgedessen vor allem in schlecht kontrastierten oder stark verkalkten Gefäßen eine weitere Verifizierung des Befundes nötig, um unnötige invasive DSAs als Folge von falsch positiven CTA-Befunden zu reduzieren.
Darmsonographie bei Kindern – Vergleich von fundamentaler und harmonischer Bildgebung. Ziel: Die harmonische Bildgebung (Harmonic Imaging, HI) wurde eingeführt, um für übergewichtige Erwachsene die Ultraschall-Untersuchung zu verbessern. Inwiefern sie auch für Kinder von Vorteil ist, die aufgrund ihrer physikalischen Eigenschaften bessere Untersuchungsbedingungen als Erwachsene bieten, ist bisher nur wenig untersucht worden. Die vorliegende Arbeit beschäftigt sich mit der Frage, ob mit HI bei der Darmsonographie von Kindern eine Verbesserung gegenüber Fundamental Imaging (FI) eintritt. Material und Methode: Bei 90 Kindern (w:m=46:44) wurden mit einem linearen 7,5MHz- Schallkopf jeweils vier Bildpaare des Darms in fundamentaler und harmonischer Bildgebung (THI- Sonoline Elegra®, Siemens) angefertigt. Die Bilder wurden anhand einer zehnstufigen Skala evaluiert. Zudem wurde der Einfluss von Alter, Geschlecht und BMI-FAP auf die Darstellbarkeit des Darms untersucht und darauf geachtet, ob Darmpathologien wie Wandverdickung und Dilatation vorliegen. Ergebnisse: Bei 17 Patienten wurde jeweils ein Bildpaar ausgeschlossen. Die harmonische Bildgebung war der fundamentalen Bildgebung in allen untersuchten Parametern signifikant überlegen (p<0,001). HI war bei 90 Patienten bei der Wand des Darms 81-mal, beim Lumen des Darms 85-mal und bei der Bildqualität 85-mal FI überlegen. Bei 19 der Kinder wurden Darmpathologien detektiert (15x Dilatation, 2x Wandverdickung und 2x Dilatation+Wandverdickung). Es besteht eine inverse Korrelation zwischen dem BMI-FAP und der Darstellbarkeit des Lumens bzw. der Bildqualität, unabhängig von der verwendeten Methode. Schlussfolgerungen: Bei der Sonographie des Darms im Kindesalter zeigt sich die harmonische Bildgebung der fundamentalen Bildgebung signifikant überlegen. Es sollte daher bei Fragestellungen, die den Darm betreffen, auch in der Pädiatrie bevorzugt Harmonic Imaging angewendet werden.
Obwohl der klinische Stellenwert der MRT in zahlreichen Studien für verschiedene Entitäten (AC-Komplex, coracoidale Pathologien, Rotatorenmanschette, Pathologien des Kapsel-Band-Apparates und der Bicepssehne sowie primär und reaktiv bedingte entzündliche Veränderungen) belegt ist, überrascht es, dass in der Literatur keine Arbeiten darüber existieren, inwieweit das Ergebnis der MRT-Untersuchung tatsächlich das therapeutische Procedere beeinflusst. Vorliegende Arbeit untersuchte daher den diagnostischen Impact der MRT im Setting einer hochspezialisierten Schultersprechstunde.
Durch Weiterentwicklungen der MR-Technologie hat die diffusionsgewichtete MRT in der Bildgebung des Abdomens zunehmend an Bedeutung gewonnen. Einige wenige Studien zeigten bereits vielversprechende Ergebnisse für den Einsatz der DWI in der Diagnostik und Verlaufsbeurteilung des Morbus Crohn.
Ziel dieser Arbeit war es, zu untersuchen, ob die DWI zur Detektion entzündlicher Darmwandläsionen und extraluminaler Komplikationen bei pädiatrischen Patienten mit Morbus Crohn ebenso geeignet ist wie die kontrastmittelverstärkte MRT.
Hierzu wurden retrospektiv die klinischen und MR-tomographischen Daten von 48 Kindern, Jugendlichen und jungen Erwachsenen mit Morbus Crohn sowie von 42 Kontrollpatienten ausgewertet, bei denen im Zeitraum zwischen Juli 2008 und Mai 2013 eine MRT-Untersuchung durchgeführt wurde. Aktuelle Befunde einer Ileokoloskopie waren als Referenz bei 60% der Morbus Crohn Patienten und bei etwa einem Drittel der Patienten der Kontrollgruppe vorhanden.
Das Bestehen eines Morbus Crohn konnte bei 47 der insgesamt 48 Patienten anhand der diffusionsgewichteten Sequenzen und in 46 Fällen mittels der kontrastverstärkten T1w-Aufnahmen korrekt nachgewiesen werden. Extramurale Komplikationen wie Abszesse oder Fisteln konnten sowohl mittels DWI als auch durch die KM-MRT detektiert werden. Da die DWI weder eine intravenöse Kontrastmittelapplikation noch Atemanhaltetechniken erfordert, ist sie gerade bei pädiatrischen Patienten ein geeignetes Bildgebungsverfahren. Wegen der relativ geringen Ortsauflösung der diffusionsgewichteten Sequenzen sollte jedoch zusätzlich eine Standardsequenz, wie die T2-gewichtete HASTE-Sequenz, akquiriert werden.
Nach den Ergebnissen dieser Studie ist die diffusionsgewichtete MRT zur Beurteilung der entzündlichen Veränderungen des Morbus Crohn sehr gut geeignet und besitzt das Potenzial, nicht nur ergänzend, sondern als Alternative zur KM-MRT zum Einsatz zu kommen.
Background
Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition.
Case presentation
We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid.
Conclusion
PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit.
Background:
Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA).
Methods:
Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0–50 and 800 s/mm\(^2\)). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm\(^2\) were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence.
Results:
Fourteen (44%) patients had active synovitis and joint effusion, nine (28%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging.
Conclusion:
Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to “T2w shine-through” artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation.
Scannereigene akustische Aktivierung - Eine neue Pulssequenz vereinfacht fMRT des auditiven Kortex
(2007)
Echo-planar Imaging (EPI) erzeugt durch schnell wechselnde Gradienten beträchtliche Schallemissionen. Dies führt nachgewiesenermaßen bei funktionellen Magnet-Resonanz-Tomographie- (fMRT-) Studien zu einer Aktivierung des auditiven Systems, insofern dieses beim jeweiligen Probanden in der Lage ist zu reagieren. Sowohl für auditive wie auch für nicht-auditive Untersuchungen wurden verschiedenste Anstrengungen unternommen, diese Interferenzen zu minimieren. Anstatt den Lärm des Scanners zu reduzieren oder die Transmission des Schalls zu behindern, war es nun das Ziel, eben diesen Schall zur Aktivierung des auditiven Kortex zu benutzen und diese mit fMRT-Untersuchungen nachzuweisen. Dieses geschieht schlicht durch das Auslassen von Read-Outs aus der Gradientenfolge der Pulssequenz. Diese Pulse sind die Hauptemissionsquellen von Schall des EPI, sie verursachen sowohl den Spitzenschallpegel als auch die Grundfrequenz, welche im umgekehrten Verhältnis zum Echo-Spacing steht. Durch eine Modell-gestützte Analyse wird gezeigt, dass das Auslassen von Read-Outs nach einem vordefinierten Schema verlässlich dazu geeignet ist, eine hämodynamische Blood-Oxygenation-Level-Dependent- (BOLD-) Signalveränderung im auditiven Kortex von normal hörenden Probanden (n=60) zu evozieren. Um den Nutzen der Technik beim auditiven fMRI zu zeigen, werden auf der Ebene der Einzelanalysen das traditionelle Family-Wise-Error-Rate- (FWER-) korrigierte Maximum Height Thresholding mit dem Spatial Mixture Modelling (SMM) verglichen. Mit Letzterem können so in 95 % der Fälle eine adäquate, bilaterale, auditive Aktivierung nachwiesen werden, wohingegen das FWER-basierte Voxel-Thresholding nur in 72 % aller Probanden eine solche Aktivierung zeigt. Um die klinische Anwendbarkeit der Technik unter pathologischen Bedingungen zu demonstrieren, wird ein Fallbericht einer Patientin vorgestellt, die an einem schweren, beidseitigen Sensorineural Hearing Loss (SNHL) aufgrund bilateraler Large Vestibular Aqueducts (LVAs) leidet. Dabei wird eben diese Modifikation benutzt, um präoperativ vor Cochlear Implantation (CI) zu zeigen, dass ein zentrales Resthörvermögen vorhanden ist. Da die Untersuchung völlig unabhängig von der Compliance des Patienten und kein zusätzliches Zubehör zum Scanner vonnöten sind, eignet sie sich hervorragend zu auditiven Untersuchungen, um so schnell das Hörvermögen zu prüfen. Dabei funktioniert die Methode unabhängig von äußerlichen Bedingungen: Bei hörgesunden Probanden ebenso wie bei Hörgeschädigten, bei Kindern, Jugendlichen und Erwachsenen aller Altersstufen sowie unabhängig von einer Sedierung während der Untersuchung. Beide benutzten Scanner zeigten unabhängig vom Gradienten oder der verwendeten Spule ein gleiches Ergebnis.
Die diffusionsgewichtete Magnetresonanztomographie (DW-MRT) ist ein fester Bestandteil der radiologischen Diagnostik des Zentralnervensystems (ZNS), und zwar nicht nur bei Schlaganfällen sondern zunehmend auch bei Hirntumoren, Schädelhirntraumata, demyelinisierenden, degenerativen sowie entzündlichen Erkrankungen. Diese Pathologien gehen in der Regel mit einer Veränderung der lokalen Diffusionsbedingungen einher, die eine reguläre Diffusionsbildgebung beeinträchtigen. Durch die Bestimmung der Diffusionsparameter lassen sich mit Hilfe verschiedener mathematischer Verfahren Faserverbindungen visualisieren. Wie sich diese unterschiedlichen Methoden in Regionen mit aversiven Diffusionsbedingungen verhalten, konnte mit der Arbeit erstmals systematisch gezeigt werden. Hierzu wurden 29 Patientenuntersuchungen ausgewertet. Als Einschlusskriterium galt eine unilaterale, diffusionsrelevante Läsion mit Bezug zur Pyramidenbahn. Ausschlusskriterium war eine vollständige Hemiparese als Zeichen einer vollständigen Zerstörung der relevanten Leitungsbahn. Im Einzelnen handelte es sich bei den untersuchten Läsionen um drei höhergradige Astrozytome (WHO Grad III-IV), drei niedriggradige Astrozytome, acht Glioblastome, zwei Karzinommetastasen, zwei arteriovenöse Malformationen und je eine entzündliche Parasitose, ein Oligodendrogliom, eine Gliomatose und ein Kavernom. Untersucht wurden zwei deterministische (einfaches und interpoliertes streamlining) und drei probabilistische Methoden (ohne crossing fibers; mit Berechnung von zwei Fasern pro Voxel und constrained/bayesian). Läsionen jeglicher Art verursachten signifikant mehr Fehlschläge bei deterministischer als bei probabilistischer Traktographie. In neun Untersuchungen bei einfacher und in acht Untersuchungen bei interpolierter Traktographie zeigten sich fasch negative Ergebnisse. Probabilistisches Traktographieren eliminiert nicht falsch negative Ergebnisse, reduziert sie jedoch unter den oben genannten aversiven Difussivitätsbedingungen mit denen intraaxiale Läsionen einhergehen. Klinisches Wissen über die verbliebene Traktintegrität ermöglicht die Umwandlung der Traktographieergebnisse in Wahrscheinlichkeitswerte innerhalb eines Bayschen Modells. Außerdem ist nur unter Miteinbeziehung klinischer Informationen eine Traktographie nach dem constrained Modell möglich. Obwohl die probabilistische Traktographie weniger anfällig für falsch negative Ergebnisse ist als die deterministische, geht die erhöhte Sensitivität der Algorithmen auf Kosten der Spezifität. Dies zeigt sich in signifikant erhöhten bilateralen Traktvolumina und einem übermäßigen Unterschied der Traktvolumina von Läsionsseite zu kontralateraler Seite. Die probabilistisch, unconstrained durchgeführte Traktographie der Pyramidenbahn zeigte eine signifikant, durch die Läsion verursachte Volumenminderung des Traktes, während dies im constrained modellierten Fall durch die Daten nicht gezeigt werden konnte. Dies zeigt die Robustheit des Constrained Modells unter den aversiven klinischen Bedingungen einer intraaxialen Läsion ohne den Nachteil von erhöhten Fehltraktographien. Es kann konstatiert werden, dass sich die deterministischen Traktographieverfahren zur präoperativen Orientierung vor neurochirurgischen Eingriffen eignen. Jedoch ist eine nicht zu unterschätzende Anzahl von falsch negativen Ergebnissen zu berücksichtigen. In zweifelhaften Fällen sollte zusätzlich eine Darstellung mittels probabilistischen Algorithmen, am besten mittels Constrained Modell durchgeführt werden.
In unserer Studie kamen die neuen Verfahren qualitative und semiquantitative Elastographie zum Einsatz. Es sollte gezeigt werden, ob sie als Ergänzung zu den herkömmlichen sonographischen Verfahren die Diagnosestellung von Erkrankungen am Hals bei Kindern und Jugendlichen verbessern können.
Bei der Untersuchung mittels semiquantitativer Elastographie konnten wir in unserer Studie beim Vergleich Schilddrüsen-Normalbefund und Hashimoto-Thyreoiditis einen signifikanten Unterschied der Scherwellengeschwindigkeiten nachweisen. Es zeigte sich, dass Patienten mit Hashimoto-Thyreoiditis signifikant höhere Scherwellengeschwindigkeiten aufweisen als Patienten mit Normalbefund. Für die anderen untersuchten Schilddrüsenerkrankungen, Struma diffusa und Struma nodosa und für die Erkrankungen der Lymphknoten, benigne Veränderung/Entzündung, maligne Veränderung und Abszess, ließ sich kein signifikanter Unterschied feststellen.
Die Sensitivität und Spezifität konnte durch Einsatz des neuen Verfahrens der qualitativen Elastographie nicht gesteigert werden. Während sich bei der Schilddrüsendiagnostik geringere Werte für Sensitivität und Spezifität im Vergleich zu den herkömmlichen Verfahren zeigten, unterschieden sich die Werte bei der Lymphknotenuntersuchung Reader-abhängig.
Bei der Schilddrüsenuntersuchung lag die Bildqualität der konventionellen Sonographie über der der qualitativen Elastographie. Dagegen wurde bei der Lymphknotenuntersuchung die Bildqualität der Elastographiebilder höher bewertet als jene der herkömmlichen Verfahren.
Insgesamt konnte in unserer Studie gezeigt werden, dass Patienten mit Hashimoto-Thyreoiditits signifikant höhere Scherwellengeschwindigkeiten im Schilddrüsengewebe aufweisen, als bei Normalbefund. In der Diagnostik von Schilddrüsen- und Lymphknotenerkrankungen konnte bezüglich des neuen Verfahrens der qualitativen Elastographie eine Überlegenheit gegenüber der konventionellen Sonographie nicht nachgewiesen werden.
Um die Ergebnisse unserer Studie abschließend bewerten zu können, wäre eine Validierung anhand einer größeren Patientengruppe nötig.
Background
Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF.
Methods
Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism.
Results
Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy.
Conclusions
The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism.
ZIEL: In den letzten Jahren ist die kontrastverstärkte sonographische Refluxprüfung, d.h. die Miktionsurosonographie (MUS), zunehmend zu einer Alternative gegenüber der standardmäßig eingesetzten Miktions-zysturethrographie (MCU) für die Diagnostik des vesikoureteralen Reflux (VUR) geworden. Eine der Einschränkungen sind jedoch die sehr hohen Kosten des Ultraschallkontrastmittels. Durch Entwicklung von neuen Ultraschallkontrastmitteln erhofft man sich aufgrund vergleichbarer Bildqualität in deutlich niedrigerer Dosis entsprechend eine Reduktion der Kosten zu erreichen. Thema dieser Studie ist eines dieser neuen Ultraschallkontrastmittel (SonoVue®) mit dem in der Routine verwendeten US-Kontrastmittel Levovist® in-vitro unter Betrachtung der für die Refluxdiagnostik relevanten physikalisch-chemischen Eigenschaften zu vergleichen. MATERIAL UND METHODEN: Der in-vitro Versuchsaufbau simulierte die in-vivo durchgeführte MUS. Verwendet wurden die Abbildungsmodalitäten Fundamental und Harmonic Imaging (THI/ECI, Sonoline Elegra®, Siemens), letztere sowohl mit einem niedrigen als auch mit einem hohen Mechanical Index (MI). SonoVue® wurde in einer Konzentration von 0,25%, 0,5% und 1%, Levovist in einer Konzentration von 5% bezogen auf ein Gesamtvolumen in-vitro von 20ml getestet. Als Vergleichsparameter diente die in-vitro Kontrastdauer. Diese wurde definiert als der Zeitraum vom Beginn der Messung bis zu dem Zeitpunkt, an dem auf mehr als 50% der Bildfläche keine echogenen Mikrobläschen mehr nachweisbar waren. ERGEBNISSE: Die Änderung der oben genannten Konzentrationen hatte keinen entscheidenden Einfluss auf die Kontrastdauer von SonoVue®. Darüber hinaus konnte beim Umschalten von THI low MI auf THI high MI die Kontrastdauer von SonoVue® signifikant verlängert werden. Betrachtet man die Abbildungsmodalität THI mit hohem MI, welche routinemäßig bei Levovist® angewendet wird, so zeigte sich, dass die Kontrastdauer bei Levovist® in einer Konzentration von 5% bei 1,1 Minuten lag, bei SonoVue® hingegen erhielten wir bei einer Konzentration von 1% eine Kontrastdauer von 7,3 Minuten. Dies bedeutet, dass trotz Verwendung einer fünffach geringeren Dosis bei SonoVue® sich die Kontrastdauer in-vitro um mehr als 80% verlängerte. Darüber hinaus blieb die Kontrastdauer von SonoVue® über einen Zeitraum von 6 Stunden weitestgehend stabil, während bei Levovist® die Kontrastdauer schon nach 0,5 Stunden eine deutliche Reduktion zeigte. SCHLUSSFOLGERUNG: Es ist zu erwarten, dass SonoVue® auch bei intravesicalen Applikationen in einer deutlich niedrigeren Dosis (1% des Blasenvolumens) verwendet werden kann und dass mehrere Untersuchungen über einen längeren Zeitraum mit einer Flasche SonoVue® durchgeführt werden können. Somit würde eine Kostenreduktion erreicht werden.
This longitudinal study was performed to evaluate the feasibility of detecting the interaction between wall shear stress (WSS) and plaque development. 20 ApoE\(^{-/-}\)mice were separated in 12 mice with Western Diet and 8 mice with Chow Diet. Magnetic resonance (MR) scans at 17.6 Tesla and histological analysis were performed after one week, eight and twelve weeks. Allin vivoMR measurements were acquired using a flow sensitive phase contrast method for determining vectorial flow. Histological sections were stained with Hematoxylin and Eosin, Elastica van Gieson and CD68 staining. Data analysis was performed using Ensight and a Matlab-based "Flow Tool". The body weight of ApoE\(^{-/-}\)mice increased significantly over 12 weeks. WSS values increased in the Western Diet group over the time period; in contrast, in the Chow Diet group the values decreased from the first to the second measurement point. Western Diet mice showed small plaque formations with elastin fragmentations after 8 weeks and big plaque formations after 12 weeks; Chow Diet mice showed a few elastin fragmentations after 8 weeks and small plaque formations after 12 weeks. Favored by high-fat diet, plaque formation results in higher values of WSS. With wall shear stress being a known predictor for atherosclerotic plaque development, ultra highfield MRI can serve as a tool for studying the causes and beginnings of atherosclerosis.
In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be quantified by means of noise and SNR calculations. An SNR gain can be traded for a reduced scan time, i.e., additional undersampling, or for an enhanced image quality, keeping scan time constant.
Acceleration of MR imaging is especially important in dynamic applications, since these examinations are inherently time-consuming. The impact of wave-CAIPI sampling on image quality and its potential for scan time reduction was investigated for two dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI.
Dynamic 3D Lung MRI
By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans could be enhanced. Volunteer examinations were used to quantify image quality by means of similarity between accelerated and reference images. To this end, the normalized mutual information and the root-mean-square error were chosen as quantitative image similarity measures.
The wave-CAIPI sampling was shown to exhibit superior quality, especially for short scan times. The values of the normalized mutual information were (10.2 +- 7.3)% higher in the wave-CAIPI case -- the root-mean-square error was (18.9 +- 13.2)% lower on average. SNR calculations suggest an average SNR benefit of around 14% for the wave-CAIPI, compared to Cartesian sampling.
Resolution of the lung in 8 breathing states can be achieved in only 2 minutes. By using the wave-CAIPI k-space trajectory, precise tumor delineation and assessment of respiration-induced displacement is facilitated.
Cardiac 4D Flow MRI
In 4D flow MRI, acceleration of the image acquisition is essential to incorporate the corresponding scan protocols into clinical routine. In this work, a retrospective 6-fold acceleration of the image acquisition was realized. Cartesian and wave-CAIPI 4D flow examinations of healthy volunteers were used to quantify uncertainties in flow parameters for the respective sampling schemes.
By employing wave-CAIPI sampling, the estimated errors in flow parameters in 6-fold accelerated scans could be reduced by up to 55%. Noise calculations showed that the noise level in 6-fold accelerated 4D flow acquisitions with wave-CAIPI is 43% lower, compared to Cartesian sampling. Comparisons between Cartesian and wave-CAIPI 4D flow examinations with a prospective acceleration factor R=2 revealed small, but partly statistically significant discrepancies. Differences between 2-fold and 6-fold accelerated wave-CAIPI scans are comparable to the differences between Cartesian and wave-CAIPI examinations at R=2.
Wave-CAIPI 4D flow acquisitions of the aorta could be performed with an average, simulated scan time of under 4 minutes, with reduced uncertainties in flow parameters. Important visualizations of hemodynamic flow patterns in the aorta were only slightly affected by undersampling in the wave-CAIPI case, whereas for Cartesian sampling, considerable discrepancies were observed.
Purpose
The aim of this study was to compare the wave‐CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free‐breathing 4D lung MRI.
Methods
The wave‐CAIPI k‐space trajectory was implemented in a respiratory self‐gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave‐CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study.
Results
The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave‐CAIPI approach. Average normalized mutual information values of the wave‐CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave‐CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave‐CAIPI.
Conclusion
The application of the wave‐CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave‐CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.
In der S3-Leitlinie „Diagnostik und Therapie des Morbus Crohn“ von 2008 war lediglich die Sonographie als primär bildgebendes Verfahren verankert; der Einsatz der Dünndarm-MRT blieb optional und ohne feste Position im Diagnostik-Algorithmus der CED. Im Unterschied hierzu stärkt die 2014 aktualisierte entsprechende S3-Leitlinie den Stellenwert der MRT als bildgebende Modalität. Weiterhin bestehen bleibt die Sonographie als primäre Bildgebung; eine MRT soll jedoch ebenfalls erfolgen: zur Primärdiagnostik, zur Erkennung extraintestinaler Komplikationen und zur Beurteilung endoskopisch nicht einsehbarer Darmabschnitte. Darüber hinaus kann sie in Verlaufskontrollen angewendet werden, falls erforderlich. Da sich diese jungen Patienten bei langer Krankheitsdauer in der Regel einer hohen Zahl an Untersuchungen unterziehen, sollte die Möglichkeit, dies strahlenexpositionsfrei durchführen zu können, unbedingt gewährleistet werden. Andernfalls ist mit einer erhöhten Rate an Malignomen im späteren Lebensalter zu rechnen.
Daraus ergibt sich die Bedeutung einer Korrelation von mittels Ultraschall wie MRT erhobenen Befunden bei kindlicher CED. Hierzu liegen bislang nur wenige Untersuchungen vor, die zumeist auf den additiven Wert der Sonographie zur MRT und/oder dem additiven Wert der MR-Perfusionsanalyse fokussieren. Der hier vorgestellte Ansatz einer direkten Korrelation der Parameter Wanddicke und Perfusionsmarker zwischen Sonographie und MRT sowie gegenüber klinischen Aktivitätsmarkern (shPCDAI) ist innovativ.
Für das MRT konnten wir eine signifikante Korrelation von Wanddicke und Signalintensitätszunahme zwei Minuten nach Kontrastmittelgabe für das terminale Ileum, der Prädilektionsstelle des Morbus Crohn, nachweisen. Ein Zusammenhang zwischen Wanddicke und klinischem Aktivitätsindex konnte nicht gezeigt werden, jedoch zwischen Signalintensitätszunahme und short PCDAI. Die Perfusionsanalyse sollte daher unserer Ansicht nach bei MRT-Untersuchungen zur Beantwortung der Frage „aktive Entzündung“ herangezogen werden.
Für die Sonographie konnten wir keinen Zusammenhang von Wanddicke und Perfusion, jedoch eine signifikante Korrelation von Wanddicke und short PCDAI nachweisen. Die Perfusion korrelierte wiederum nicht mit dem klinischen Aktivitätsindex. Die morphologische Wanddickenanalyse sollte daher für Sonographie-Untersuchungen zur Beantwortung der Frage „aktive Entzündung“ herangezogen werden.
Bei der Korrelation der MRT- und Sonographie-Ergebnisse zeigte sich ein gutes Übereinstimmen der Daten der Darmwanddicken-Messungen, die höchste Korrelation ergab sich im terminalen Ileum. Auch für Signalintensitätszunahmen (MRT) und Perfusion (FKDS) zeigte sich ein gutes Übereinstimmen – mit Ausnahme des Rektosigmoids (späte KM-Phase). Die größte Korrelation war auch hier im terminalen Ileum zu finden. Dies belegt die gute Vergleichbarkeit beider Modalitäten. Eine Korrelation von MRAIs – USAI – shPCDAI ließ sich nicht nachweisen. Dies könnte an einer divergenten Einschätzung der Erkrankungsaktivität, jedoch auch an der kleinen Fallzahl liegen. Zur Erstellung des shPCDAI waren die retrospektiv erhobenen Variablen teils nicht ausreichend. Hauptlimitation für den USAI war die – teils durch Darmgasüberlagerung bedingte – unvollständige Dokumentation. Die Stärke des MRAI lag dagegen bei konstant vorliegenden Messungen in fünf Darmabschnitten.
Trotz dieser Limitationen belegt die vorliegende Arbeit die Gleichwertigkeit beider Methoden in der Beurteilung von Darmwanddicken und eine bessere Korrelation wie Aussagekraft der MRT bei der Perfusionsanalyse. Aktuelle Publikationen belegen die Bedeutung Diffusionsgewichteter-MR-Bildgebung bei der CED-Diagnostik. Die DWI wurde im Rahmen unserer Untersuchung nicht angewendet, wird aber in Zukunft als vielversprechender, additiver Baustein oder sogar Ersatz für die Kontrastmittelgabe (Perfusionsanalyse) für MRT bei CED zu evaluieren sein.
Die 31P-MRS ist aktuell die einzige verfügbare nicht-invasive Methode mit der der Herzmetabolismus ohne radioaktive Tracer untersucht werden kann. MRS ermöglicht Einblicke in die Energetik der ischämischen Herzkrankheit, des Herzinfarkts, der hypertrophen Kardiomyopathie oder auch der Herzklappenfehler. Ferner kann die Methode zur Überwachung des Therapieerfolgs o.g. Krankheiten genutzt werden. Gegenwärtig wird die MR-Spektroskopie, aufgrund der geringen räumlichen und zeitlichen Auflösung sowie der geringen Reproduzierbarkeit, jedoch nur in der Forschung angewendet. Die Einführung von MRT-Sytemen höherer Feldstärke, z.B. 7 Tesla, wird vermutlich eine Optimierung der Auflösung und Reproduzierbarkeit ermöglichen und damit die 31P-MRS in die klinische Diagnostik integrieren können. Die vorliegende Arbeit befasst sich neben der methodischen Weiterentwicklung und Standardisierung der MRS mit einem direkten Vergleich MR-tomographischer (LE) und MR-spektroskopischer (AW-CSI) Techniken zur Detektion von Infarktfolgen. Hierbei konnte durch die simultane Anwendung von MRS und Late Enhancement, ein bereits in der klinischen Infarktdiagnostik etabliertes Verfahren, die Aussagekraft der MR-Spektroskopie in Bezug auf die Infarktlokalisation validiert werden. Ein wesentlicher Vorteil der MRS gegenüber dem Late Enhancement besteht darin, dass bereits frühzeitig pathologische Veränderungen des Metabolismus in Arealen wie dem remote, stunned oder hibernating myocardium detektiert werden können. Letztere demarkieren sich nicht beim LE. Unter Etablierung eines Segmentationsalgorithmus konnten sehr niedrige Variabilitäten bei dem verwendeten Quantifizierungsprogramm („SLOOP“) erreicht werden. Zusätzlich gelang es durch systematische Analysen die für die Auswertung der MRS benötigten Nachbearbeitungszeiten drastisch zu verkürzen. Als klinische Anwendung erfolgte die Bestimmung des kardialen Metabolismus mittels akquisitionsgewichteter 31P-3D-CSI bei Patienten mit Hinterwandinfarkt. Damit konnten erstmalig spulenferne Myokardareale (Hinterwand) hinsichtlich Veränderungen im Metabolismus erfasst werden. Veränderte PCr/γATP-ratios wurden bei Infarktpatienten gegenüber einem Kollektiv herzgesunder Probanden gefunden. Eine exakte Lokalisation der untersuchten Infarkte und damit eine Validierung der spektroskopischen Datenanalyse wurden durch den Vergleich mit den simultan aufgenommenen Late Enhancement Bildern möglich. Damit eröffnet sich in Verbindung mit zunehmend zur Verfügung stehenden Hochfeldgeräten (3T und mehr) für die MRS der Weg zu einem wichtigen klinischen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen.
Mit dem hier vorgestellten Untersuchungs- und Auswertealgorithmus konnte die Myokardperfusion weitgehend automatisiert semiquantitativ und quantitativ bestimmt werden. Dafür wurden zunächst die Bilddaten segmentiert und in Signalintensitäts-Zeit-Kurven transferiert. Durch eine Basislinien- und Kontaminationskorrektur wurden Artefakte minimiert. Mit Anwendung des Parallel-Bildgebungs-Verfahrens Auto-SENSE konnte zusätzlich eine Erhöhung der Schichtanzahl erreicht werden. Durch die angewendete Basislinienkorrektur konnten Inhomogenitäten verringert werden, welche durch Verwendung einer Oberflächenspule methodenbedingt auftreten. Partialvolumeneffekte, die durch die Morphologie des Herzens insbesondere basis- und spitzennah auftraten, führten durch eine Mischung aus KM-Anflutung im Myokard und Kontamination aus dem Ventrikellumen zu einer Beeinflussung der Perfusionsergebnisse. Durch die Verwendung der vorgestellten Kontaminationskorrektur konnten diese Artefakte erheblich minimiert werden. Die so errechneten Perfusionswerte korrelierten gut mit den in der Literatur angegebenen Daten, welche sowohl in tierexperimentellen als auch Probanden- und auch Patientenstudien mit unterschiedlichen Modalitäten ermittelt wurden. Eine regionale Heterogenität konnte nicht signifikant nachgewiesen werden. Molekular-physiologische Untersuchungen legen zwar nahe, dass es diese Heterogenität gibt, die regionale Verteilung der Perfusion wird jedoch kontrovers und noch keinesfalls abschließend in der Literatur diskutiert. Durch Anwendung von Auto-SENSE konnte mit einer Erhöhung der Schichtanzahl bei gleichbleibender Schichtdicke das gesamte linksventrikuläre Myokard untersucht werden. Trotz verringertem SNR waren die Ergebnisse vergleichbar mit der konventionellen Turbo-FLASH-Technik. Ob das Potential der Parallelbildgebung für eine Abdeckung des gesamten Herzens oder für eine höhere Auflösung von 3-4 Schichten pro Untersuchungen genutzt werden soll, ist in der aktuellen Literatur noch Gegenstand der Diskussion. Die hochaufgelösten Untersuchungen scheinen jedoch derzeit vorteilhafter aufgrund geringerer Partialvolumeneffekte sowie der besseren Beurteilbarkeit einer subendokardialen Zone und eines transmuralen Perfusionsgradienten. Die MR-Perfusionsbildgebung ist ein aktives und rasch wachsendes Gebiet innerhalb der kardialen Bildgebung mit großem Entwicklungspotential. Durch Einbindung in ein umfassendes Herz-MR-Untersuchungsprotokoll (z.B. Morphologie, Kinetik, evtl. MR-Koronarangiographie) ist in einem Untersuchungsgang eine umfassende Diagnostik bei Patienten mit Verdacht auf KHK möglich.
Background
Diagnosis of subscapularis (SSC) tendon lesions on magnetic resonance imaging (MRI) can be challenging. A small coracohumeral distance (CHD) has been associated with SSC tears. This study was designed to define a specific threshold value for CHD to predict SSC tears on axial MRI scans.
Methods
This retrospective study included 172 shoulders of 168 patients who underwent arthroscopic surgery for rotator cuff tear or glenohumeral instability. Diagnostic arthroscopy confirmed an SSC tear in 62 cases (36.0%, test group a), rotator cuff tear tears other than SSC in 71 cases (41.3%, control group b) and glenohumeral instability without any rotator cuff tear in 39 cases (22.7%, zero-sample group c). All patients had a preoperative MRI of the shoulder (1.5T or 3T). Minimum CHD was measured on axial fat-suppressed proton density-, T2-, or T1-weigthed sequences. Receiver operating characteristics analysis was used to determine the threshold value for CHD, and sensitivity and specificity were calculated.
Results
CHD measurement had a good interobserver reliability (Intraclass correlation coefficient 0.799). Mean CHD was highly significantly (P < .001) less for test group a (mean 7.3 mm, standard deviation ± 2.2) compared with control group b (mean 11.1 mm, standard deviation ± 2.3) or zero-sample group c (mean 13.6 mm, standard deviation ± 2.9). A threshold value of CHD <9.5 mm had a sensitivity of 83.6% and a specificity of 83.9% to predict SSC tears.
Conclusion
A CHD <9.5 mm on MRI is predictive of SSC lesions and a valuable tool to diagnose SSC tears.
Organfilter in der konventionellen Röntgendiagnostik und ihre Bedeutung für den Strahlenschutz
(2004)
Die vorliegende Arbeit untersucht den Effekt von Organfiltern insbesondere auf die Dosis. Im Rahmen dieser Untersuchung wurde die Dosis in Form des Flächendosisproduktes (FDP) gemessen. Filter bewirken nicht nur eine Verbesserung der Objektdarstellung in den normalerweise zu stark geschwärzten Randpartien, sondern auch eine Dosisreduktion, d.h. die Organfilter sind gut geeignet, den Strahlenschutz positiv zu beeinflussen. Dieser Effekt der Dosisreduktion war bei den Keilfiltern (Mittel- und Vorfuß sowie HWS) weniger deutlich als bei den für Schädel und Schulter angewendeten Filtern.
Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM.
Das Hauptziel der vorliegenden Arbeit war es, eine genauere Erkenntnis über die derzeitigen Möglichkeiten der quantitativen Messung der myokardiale Perfusion im Hinblick auf die Beschreibung verschiedener myokardialer Infarkte mittels kardialer MRT zu gewinnen. Die Untersuchungen zur Perfusion im Infarktgebiet ergaben, dass ein visuell festgestellter subendokardialer Infarkt an Hand der Bestimmung der absoluten Perfusion nicht immer nachvollzogen werden konnte. Ein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Höhe der absoluten Perfusion im Infarktgebiet konnte nicht gezeigt werden. Die Untersuchungen zur Perfusion im Remote Myokard ergaben keinen Zusammenhang zwischen der Perfusion im Remote Myokard und dem transmuralen Ausmaß des no-reflow-Phänomens in der First Pass Perfusion. Auch korrelierte die Perfusion im Remote Myokard nicht mit dem Auftreten eines no-reflow Phänomens im Late Enhancement. Die Perfusion im Remote Myokard unterschied sich zwischen transmuralen und nicht-transmuralen Infarkten. Eine Hyperperfusion im Remote Myokard konnte erst ab einer Infarktausdehnung von 75% im Late Enhancement beobachtet werden, während eine Hypoperfusion im Remote Myokard bei allen Infarktausdehnungen zwischen 0% und 100% auftrat. Die Untersuchungen zur Perfusion bei Vorliegen eines transmuralen Infarktes“ ergaben eine signifikante Korrelation der Perfusionen in Infarktgebiet und Remote Myokard bei transmuralem Infarkten. Die Ergebnisse zur Messung der Perfusion in Abhängigkeit von der relativen Infarktgröße wiesen keinen Zusammenhang zwischen der Perfusion im Infarktgebiet und der relativen Infarktgröße auf. Ebenso konnte keine Beziehung zwischen der Perfusion im Remote Myokard und der relativen Infarktgröße dargelegt werden. Letztendlich wurde das Verhalten der quantitativen Perfusion im Infarktgebiet und im Remote Myokard in Abhängigkeit von der Zeit nach Infarktereignis untersucht. Dabei zeigte sich kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Infarktgebiet zwischen der Erst- und der Spätuntersuchung. Ebenso war kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Remote Myokard zwischen der Erst- und der Spätuntersuchung erkennbar. Die kardiale MRT ist aufgrund der gleichzeitigen Analyse von morphologischen, funktionellen, quantitativen und metabolischen Parametern in einem Untersuchungsgang ein erfolgversprechendes Bildgebungsverfahren der Zukunft, da sie nicht invasiv ist, ohne Einsatz von Röntgenstrahlung auskommt und dabei eine gute räumliche Auflösung bei hohem Gewebekontrast bietet. Studien zeigen, dass die Kombination von Stress-Perfusion und Late-Technik in einem MRT-Protokoll eine höhere Genauigkeit als die Verwendung der SPECT-Untersuchung in der klinischen Beurteilung von Koronargefäßstenosen und im Nachweis subendokardialer Infarkte aufweist. 62 Allerdings erfährt die in vorliegender Arbeit verwendete Technik der Datenverarbeitung in dieser Form ohne Zweifel noch ihre Limitation im klinischen Alltag. Grundsätzlich ist zu sagen, dass die Messung der absoluten Perfusion im Myokard mit der MRT des Herzens zurzeit sicherlich noch nicht ausgereift ist. Dennoch lassen die in dieser Arbeit vorgestellten Ergebnisse und die viel versprechende Weiterentwicklung in der magnetresonanztomographischen Bildgebung weit reichende und interessante Möglichkeiten erahnen.
Ziel der vorliegenden Arbeit war es, einen genaueren Aufschluss über die Erfassung der mikrovaskulären Integrität von Myokardinfarkten nach erfolgreicher koronarer Revaskularisierung mittels kardialer MR-Bildgebungstechniken zu geben. Dazu wurde zuerst das Auftreten des „no-reflow“ in der FPP und im LE sowie zu verschiedenen Zeitintervallen untersucht. Die Untersuchungen hierzu ergaben ein häufigeres Auftreten des „no-reflow“ in den FPP-Untersuchungen und eine Abnahme des beobachtbaren „no-reflow“, je später die Untersuchung nach Kontrastmittelgabe erfolgte. Zusätzlich zeigte sich, dass das Auftreten eines „no-reflow“ in der LE-Untersuchung immer mit einem Auftreten in der FPP einherging. Weiterhin wurden die Auswirkungen des Infarktausmaßes auf das „no-reflow“ überprüft. Bei den Untersuchungen wurde zwischen Infarktvolumen und transmuraler Infarktgröße unterschieden. Dabei zeigte sich, dass das Auftreten eines „no-reflow“ in der FPP- und LE-Untersuchung besser mit dem relativen Infarktvolumen als mit dem transmuralen Infarktausmaß korrelierte. Infarkte mit einem relativen Volumen kleiner neun Prozent ließen kein „no-reflow“ im LE beobachten, wobei bei einem Infarktvolumen > 15 % ein „no-reflow“ sowohl in der FPP- als auch in der LE-Untersuchung beobachtbar war. Die Untersuchungen zum transmuralen Infarktausmaß zeigten, dass ein „no-reflow“ auch bei nicht transmuralen Infarkten auftrat. Daneben konnte beobachtet werden, dass auch transmurale Infarkte ohne „no-reflow“ auftreten. Des Weiteren wurden die Auswirkungen eines beobachtbaren „no-reflow“ auf die EF überprüft. Die EF wurde hierzu 14 Tage und drei Monate nach Myokardinfarkt bestimmt und mit dem „no-reflow“ in der FPP und im LE der Erstuntersuchung verglichen. Hierbei zeigten zum ersten Untersuchungszeitpunkt in der FPP-Untersuchung mehr als 50 % der Infarkte sowohl bei einer EF < 55 % als auch bei einer EF > 55 % ein „no-reflow“. Dagegen war in der LE-Untersuchung bei einer EF < 55 % kein Unterschied bezüglich der Beobachtung eines „no-reflow“ feststellbar, während bei einer EF > 55 % über 70 % der Infarkte kein „no-reflow“ aufwiesen. In der „Untersuchung nach drei Monaten“ zeigten in der FPP-Untersuchung bei einer EF < 55 % knapp 75 % der Infarkte ein „no-reflow“, während es bei einer EF > 55 % ungefähr 25 % waren. In der LE-Untersuchung war, ähnlich dem ersten Untersuchungszeitpunkt, bei einer EF < 55 % kein wesentlicher Unterschied festzustellen, wohingegen bei einer EF > 55 % über 75 % der Infarkte kein beobachtbares „no-reflow“ im LE zeigten. Für die FPP- und LE-Untersuchung ergab sich bei beiden Untersuchungszeitpunkten kein statistischer signifikanter Unterschied bezüglich der EF der Patienten, die „no-reflow“ zeigten, zu den Patienten, die kein „no-reflow“ zeigten. Ohne Zweifel ist die kardiale MRT aufgrund des nichtinvasiven dreidimensionalen Charakters und des guten Gewebekontrastes ohne Einsatz von Röntgenstrahlung ein viel versprechendes bildgebendes Verfahren der Zukunft. Der Vorteil der Anwendung dieses Verfahrens bei Patienten mit Myokardinfarkt ist die präzise Bewertung des transmuralen Ausmaßes der myokardialen Nekrose sowie des „no-reflow“ und die gleichzeitige Erfassung der Herzfunktionsparameter. Der Stand der Erfassung und Bewertung des „no-reflow“ in MRT-Bildern reicht jedoch zurzeit noch nicht für den Einsatz in der klinischen Routinediagnostik aus. Die in dieser Arbeit vorgestellten Ergebnisse sollen einen Beitrag für diese Weiterentwicklung leisten. Für einen späteren Standard zur Erfassung der mikrovaskulären Integrität beim Akuten Koronarsyndrom sind jedoch weitere Studien nötig. Hierbei wären genauere Untersuchungen zum Schweregrad des „no-reflow“ sowie zum Auftreten zu verschiedenen Zeitpunkten sinnvoll. Außerdem sollten exaktere Aussagen über die Korrelation des Auftretens des „no-reflow“ und den Herzfunktionsparametern erhoben werden. Es ist anzunehmen, dass sich durch eine Weiterentwicklung der kardialen MRT der Informationsgehalt in Zukunft stetig steigern wird und dadurch eine eindrucksvolle Ergänzung der kardiologischen Differentialdiagnostik sein. Dabei könnte eine multimodale Akquisition der kardialen Makro- und Mikrozirkulation, pathologischer Gewebeveränderungen und myokardialer Funktionsstörungen in einem Untersuchungsgang mit einem kurzen zeitlichen Aufwand erreicht werden. Durch Integration der MRT-Untersuchungen zum „no-reflow“ in den klinischen Alltag könnte somit eine Bestimmung des individuellen Risikos sowie ein risikoadaptiertes Behandlungskonzept erreicht werden.
This work deals with the acceleration of cardiovascular MRI for the assessment
of functional information in steady-state contrast and for viability assessment
during the inversion recovery of the magnetization. Two approaches
are introduced and discussed in detail. MOCO-MAP uses an exponential
model to recover dynamic image data, IR-CRISPI, with its low-rank plus
sparse reconstruction, is related to compressed sensing.
MOCO-MAP is a successor to model-based acceleration of parametermapping
(MAP) for the application in the myocardial region. To this end, it
was augmented with a motion correction (MOCO) step to allow exponential
fitting the signal of a still object in temporal direction. Iteratively, this
introduction of prior physical knowledge together with the enforcement of
consistency with the measured data can be used to reconstruct an image
series from distinctly shorter sampling time than the standard exam (< 3 s
opposed to about 10 s). Results show feasibility of the method as well as
detectability of delayed enhancement in the myocardium, but also significant
discrepancies when imaging cardiac function and artifacts caused already by
minor inaccuracy of the motion correction.
IR-CRISPI was developed from CRISPI, which is a real-time protocol
specifically designed for functional evaluation of image data in steady-state
contrast. With a reconstruction based on the separate calculation of low-rank
and sparse part, it employs a softer constraint than the strict exponential
model, which was possible due to sufficient temporal sampling density via
spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on
dynamic and on inversion recovery data. Thus, motion correction is rendered
unnecessary with it.
IR-CRISPI was equipped with noise suppression via spatial wavelet filtering.
A study comprising 10 patients with cardiac disease show medical
applicability. A comparison with performed traditional reference exams offer
insight into diagnostic benefits. Especially regarding patients with difficulty
to hold their breath, the real-time manner of the IR-CRISPI acquisition provides
a valuable alternative and an increase in robustness.
In conclusion, especially with IR-CRISPI in free breathing, a major acceleration
of the cardiovascular MR exam could be realized. In an acquisition
of less than 100 s, it not only includes the information of two traditional
protocols (cine and LGE), which take up more than 9.6 min, but also allows
adjustment of TI in retrospect and yields lower artifact level with similar
image quality.
Squamous cell carcinomas (SCC) frequently have an exceptionally high mutational burden. As consequence, they rapidly develop resistance to platinum-based chemotherapy and overall survival is limited. Novel therapeutic strategies are therefore urgently required. SCC express ∆Np63, which regulates the Fanconi Anemia (FA) DNA-damage response in cancer cells, thereby contributing to chemotherapy-resistance. Here we report that the deubiquitylase USP28 is recruited to sites of DNA damage in cisplatin-treated cells. ATR phosphorylates USP28 and increases its enzymatic activity. This phosphorylation event is required to positively regulate the DNA damage repair in SCC by stabilizing ∆Np63. Knock-down or inhibition of USP28 by a specific inhibitor weakens the ability of SCC to cope with DNA damage during platin-based chemotherapy. Hence, our study presents a novel mechanism by which ∆Np63 expressing SCC can be targeted to overcome chemotherapy resistance. Limited treatment options and low response rates to chemotherapy are particularly common in patients with squamous cancer. The SCC specific transcription factor ∆Np63 enhances the expression of Fanconi Anemia genes, thereby contributing to recombinational DNA repair and Cisplatin resistance. Targeting the USP28-∆Np63 axis in SCC tones down this DNA damage response pathways, thereby sensitizing SCC cells to cisplatin treatment.
Background: Computed tomography (CT) pulmonary angiography is the diagnostic reference standard in suspected pulmonary embolism (PE). Favorable results for dual-energy CT (DECT) images have been reported for this condition. Nowadays, dual-energy data acquisition is feasible with different technical options, including a single-source split-filter approach. Therefore, the aim of this retrospective study was to investigate image quality and radiation dose of thoracic split-filter DECT in comparison to conventional single-energy CT in patients with suspected PE.
Methods: A total of 110 CT pulmonary angiographies were accomplished either as standard single-energy CT with automatic tube voltage selection (ATVS) (n=58), or as split-filter DECT (n=52). Objective [pulmonary artery CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] and subjective image quality [four-point Likert scale; three readers (R)] were compared among the two study groups. Size-specific dose estimates (SSDE), dose-length-product (DLP) and volume CT dose index (CTDIvol) were assessed for radiation dose analysis.
Results: Split-filter DECT images yielded 67.7% higher SNR (27.0 vs. 16.1; P<0.001) and 61.9% higher CNR (22.5 vs. 13.9; P<0.001) over conventional single-energy images, whereas CT attenuation was significantly lower (344.5 vs. 428.2 HU; P=0.013). Subjective image quality was rated good or excellent in 93.0%/98.3%/77.6% (R1/R2/R3) of the single-energy CT scans, and 84.6%/82.7%/80.8% (R1/R2/R3) of the split-filter DECT scans. SSDE, DLP and CTDIvol were significantly lower for conventional single-energy CT compared to split-filter DECT (all P<0.05), which was associated with 26.7% higher SSDE.
Conclusions: In the diagnostic workup of acute PE, the split-filter allows for dual-energy data acquisition from single-source single-layer CT scanners. The existing opportunity to assess pulmonary “perfusion” based on analysis of iodine distribution maps is associated with higher radiation dose in terms of increased SSDE than conventional single-energy CT with ATVS. Moreover, a proportion of up to 3.8% non-diagnostic examinations in the current reference standard test for PE is not negligible.
Objective:
Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals.
Methods:
Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses.
Results:
In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28% (interquartile range [IQR] 0.17–0.42%) in male and 0.24% (IQR 0.14–0.45%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g).
Conclusions:
The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers.
Objectives
To investigate the feasibility, diagnostic image quality and radiation dose of 3\(^{rd}\) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease.
Methods
We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scanprotocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP).
Results
All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv.
Conclusions
Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases.
Purpose
To evaluate whether a deep learning model (DLM) could increase the detection sensitivity of radiologists for intracranial aneurysms on CT angiography (CTA) in aneurysmal subarachnoid hemorrhage (aSAH).
Methods
Three different DLMs were trained on CTA datasets of 68 aSAH patients with 79 aneurysms with their outputs being combined applying ensemble learning (DLM-Ens). The DLM-Ens was evaluated on an independent test set of 104 aSAH patients with 126 aneuryms (mean volume 129.2 ± 185.4 mm3, 13.0% at the posterior circulation), which were determined by two radiologists and one neurosurgeon in consensus using CTA and digital subtraction angiography scans. CTA scans of the test set were then presented to three blinded radiologists (reader 1: 13, reader 2: 4, and reader 3: 3 years of experience in diagnostic neuroradiology), who assessed them individually for aneurysms. Detection sensitivities for aneurysms of the readers with and without the assistance of the DLM were compared.
Results
In the test set, the detection sensitivity of the DLM-Ens (85.7%) was comparable to the radiologists (reader 1: 91.2%, reader 2: 86.5%, and reader 3: 86.5%; Fleiss κ of 0.502). DLM-assistance significantly increased the detection sensitivity (reader 1: 97.6%, reader 2: 97.6%,and reader 3: 96.0%; overall P=.024; Fleiss κ of 0.878), especially for secondary aneurysms (88.2% of the additional aneurysms provided by the DLM).
Conclusion
Deep learning significantly improved the detection sensitivity of radiologists for aneurysms in aSAH, especially for secondary aneurysms. It therefore represents a valuable adjunct for physicians to establish an accurate diagnosis in order to optimize patient treatment.
Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDI\(_{vol}\) = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as “non-UHR”. Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ\(_{50}\) = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2–9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58–0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.
In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDI\(_{vol}\) 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1–3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732–0.848; p < 0.001) and fracture assessability (0.880; 0.842–0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0–3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise.
Hintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) können mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik ermöglicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualität sowie der Strahlendosis mit einem etabliertem DS-DECT-Gerät verglichen werden.
Material und Methoden: Insgesamt wurden 135 Patienten eingeschlossen, die eine CTPA erhielten: 68 erhielten einen DS-DECT-Scan mit 90/Sn150 kV und 67 einen SF-DECT-Scan mit Au/Sn120 kV. Für beide Protokolle wurden farbkodierte Joddistributionskarten erstellt. Die objektive (CT-Abschwächung in relevanten Gefäßen in HU, Signal-Rausch-Verhältnis (SNR), Kontrast-Rausch-Verhältnis (CNR), perfused blood volume (PBV)) und subjektive Bildqualität (2 Befunder (B), 5-Punkte-Likert-Skala) sowie Dosisparameter wurden erhoben und verglichen.
Ergebnisse: Alle CTPAs waren von diagnostischer Qualität. Ihre subjektive Bildqualität wurde in 80,9/82,4% (B1/B2) der DS-DECT und in 77,6/76,1% der SF-DECT als exzellent oder gut bewertet. Die subjektive Bildqualität der Joddistributionskarten der SF-DECT wurde von beiden Befundern als schlechter beurteilt. Die HU-Werte der relevanten Gefäße unterschieden sich nicht signifikant (p>0.05), SNR und CNR der SF-Gruppe waren in zentralen Gefäßen jedoch höher (p<0.05); die PBV-Werte der SF-Gruppe waren teils höher (p<0.05). Alle erhobenen Dosisparameter waren in der SF-Gruppe höher (p<0,05).
Konklusion: In der diagnostischen Abklärung eines V.a. eine akute LAE ermöglicht der Einsatz eines Split-Filters an einem Single-Source-CT-Scanner eine Dual-Energy-Untersuchung. Dies geht im Vergleich zu etablierten DS-Scannern jedoch mit einer schlechteren Qualität der Joddistributionskarten und einer höheren Strahlendosis einher.
Das Ziel dieser Arbeit war es, Methoden und Techniken für die morphologische und funktionelle Bildgebung der menschlichen Lunge mittels Kernspintomographie bei Feldstärken von 0,2 Tesla und 1,5 Tesla zu entwickeln und zu optimieren. Bei 0,2 Tesla wurde mittels der gemessenen Relaxationszeiten T1 und T2* eine 2D und eine 3D FLASH Sequenz zur Untersuchung der Lungenmorphologie optimiert. Sauerstoffgestützte Messungen der Relaxationszeiten T1 und T2* sowie eine SpinLabeling Sequenz liefern funktionelle Informationen über den Sauerstofftransfer und die Perfusion der Lungen. Bei 1,5 Tesla wurde die Lungenperfusion mittels MR-Kontrastmittel mit einer 2D und einer 3D Sequenz unter Verwendung der Präbolus Technik quantifiziert. Zudem wurden zwei MR-Navigationstechniken entwickelt, die es ermöglichen Lungenuntersuchungen unter freier Atmung durchzuführen und aus den Daten artefaktfreie Bilder zu rekonstruieren. Diese Techniken können in verschiedenste Sequenzen für die Lungenbildgebung implementiert werden, ohne dass die Messzeit dadurch signifikant verlängert wird.
Organ manifestations and long-term outcome of Fabry disease in patients with the GLA haplotype D313Y
(2016)
Objectives: The severity of Fabry disease is dependent on the type of mutation in the α-galactosidase A (AgalA) encoding gene (GLA). This study focused on the impact of the GLA haplotype D313Y on long-term organ involvement and function.
Setting and participants: In this monocentric study, all participants presenting with the D313Y haplotype between 2001 and 2015 were comprehensively clinically investigated at baseline and during a 4-year follow-up if available. Five females and one male were included.
Primary and secondary outcome measures: Cardiac, nephrological, neurological, laboratory and quality of life data.
Results: AgalA enzyme activity in leucocytes (0.3±0.9 nmol/min/mg protein (mean±SD)) and serum lyso-Gb3 (0.6±0.3 ng/mL at baseline) were in normal range in all patients. Cardiac morphology and function were normal (left-ventricular (LV) ejection fraction 66±8%; interventricular septum 7.7±1.4 mm; LV posterior wall 7.5±1.4 mm; normalised LV mass in MRI 52±9 g/m2; LV global longitudinal strain −21.6±1.9%) and there were no signs of myocardial fibrosis in cardiac MRI. Cardiospecific biomarkers were also in normal range. Renal function was not impaired (estimated glomerular filtration rate MDRD 103±15 mL/min; serum-creatinine 0.75±0.07 mg/dL; cystatin-c 0.71±0.12 mg/L). One female patient (also carrying a Factor V Leiden mutation) had a transitory ischaemic attack. One patient showed white matter lesions in brain MRI, but none had Fabry-associated pain attacks, pain crises, evoked pain or permanent pain. Health-related quality of life analysis revealed a reduction in individual well-being. At long-term follow-up after 4 years, no significant change was seen in any parameter.
Conclusions: The results of the current study suggest that the D313Y genotype does not lead to severe organ manifestations as seen in genotypes known to be causal for classical FD."
One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical …
Serotonergic modulation of 'waiting impulsivity' is mediated by the impulsivity phenotype in humans
(2016)
In rodents, the five-choice serial reaction time task (5-CSRTT) has been established as a reliable measure of waiting impulsivity being defined as the ability to regulate a response in anticipation of reinforcement. Key brain structures are the nucleus accumbens (NAcc) and prefrontal regions (for example, pre- and infralimbic cortex), which are, together with other transmitters, modulated by serotonin. In this functional magnetic resonance imaging study, we examined 103 healthy males while performing the 5-CSRTT measuring brain activation in humans by means of a paradigm that has been widely applied in rodents. Subjects were genotyped for the tryptophan hydroxylase-2 (TPH2; G-703T; rs4570625) variant, an enzyme specific for brain serotonin synthesis. We addressed neural activation patterns of waiting impulsivity and the interaction between the NAcc and the ventromedial prefrontal cortex (vmPFC) using dynamic causal modeling. Genetic influence was examined via interaction analyses between the TPH2 genotype (GG homozygotes vs T allele carriers) and the degree of impulsivity as measured by the 5-CSRTT. We found that the driving input of the vmPFC was reduced in highly impulsive T allele carriers (reflecting a reduced top-down control) in combination with an enhanced response in the NAcc after correct target processing (reflecting an augmented response to monetary reward). Taken together, we found a high overlap of our findings with reports from animal studies in regard to the underlying cognitive processes, the brain regions associated with waiting impulsivity and the neural interplay between the NAcc and vmPFC. Therefore, we conclude that the 5-CSRTT is a promising tool for translational studies.
Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury.
Popliteal cysts, or Baker cysts, are considered rare in children and may exhibit particular features, as compared with adults. We studied data from80 paediatric patients with 55 Baker cysts, examined over a period of 7 years, and correlated clinical presentation with findings on ultrasonography and MRI. Prevalence of popliteal cysts was 57% in arthritic knees, 58% with hypermobility syndrome, and 28% without risk factors. Only one patient had a trauma history and showed an ipsilateral cyst. Mean cyst volume was 3.4 mL; cysts were larger in boys. Patients with arthritis had echogenic cysts in 53%. Cyst communication with the joint space was seen in 64% on ultrasonography and 86% on MRI. In conclusion, Baker cysts are a common finding in a clinically preselected paediatric population. Children with Baker cysts should be assessed for underlying arthritis and inherited joint hypermobility, while sporadic Baker cysts appear to be common, as well.
Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies.
Background: Giant cell arteritis (GCA) is the most common systemic vasculitis in persons aged 50 and above (incidence, 3.5 per 100 000 per year). It affects cranial arteries, the aorta, and arteries elsewhere in the body, e.g., in the limbs.
Methods: We selectively review the pertinent literature, including guidelines and recommendations from Germany and abroad.
Results: The typical symptoms of new-onset GCA are bi-temporal headaches, jaw claudiacation, scalp tenderness, visual disturbances, systemic symptoms such as fever and weight loss, and polymyalgia. The diagnostic assessment comprises laboratory testing (erythrocyte sedimentation rate, C-reactive protein), imaging studies (duplex sonography, high-resolution magnetic resonance imaging, positron-emission tomography), and temporal artery biopsy. The standard treatment is with corticosteroids (adverse effects: diabetes mellitus, osteoporosis, cataract, arterial hypertension). A meta-analysis of three randomized controlled trials led to a recommendation for treatment with methotrexate to lower the recurrence rate and spare steroids. Patients for whom methotrexate is contraindicated or who cannot tolerate the drug can be treated with azathioprine instead.
Conclusion: Giant cell arteritis, if untreated, progresses to involve the aorta and its collateral branches, leading to various complications. Late diagnosis and treatment can have serious consequences, including irreversible loss of visual function.
Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words “brain”, “metastas*”, “tumor”, “colorectal”, “cancer”, and “malignancy”. In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1% and 11.5%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment.
Diese Arbeit untersucht die Fragestellung ob bei der Untersuchung von gesundem Hirngewebe und pathologischen,intrakraniellen Läsionen mittels Singelvoxel- versus Multivoxel-MR-Protonen-Spektroskopie signifikant unterschiedliche Ergebnisse bestehen. Untersucht wurden Hirntumoren der WHO-Grade 2 bis 4, Metastasen und fokal-entzündliche Läsionen. Zusammenfassend ist die Unterscheidung zwischen normalem und pathologisch verändertem Hirngewebe am besten mit der Singelvoxel-Methode und Bildung der CHO/CRE-Ratio möglich. Zur Differentialdiagnose und weiteren Malignitätseinschätzung eignet sich die Bildung der CHO/NAA-Ratio mit Singelvoxel-Spektroskopie. Weiterhin ist die parallele Anwendung von Singel- und Multivoxel-Spektroskopie empfehlenswert.
Background
Animal models are frequently used to assess new treatment methods in cancer research. MRI offers a non-invasive in vivo monitoring of tumour tissue and thus allows longitudinal measurements of treatment effects, without the need for large cohorts of animals. Tumour size is an important biomarker of the disease development, but to our knowledge, MRI based size measurements have not yet been verified for small tumours (10−2–10−1 g). The aim of this study was to assess the accuracy of MRI based tumour size measurements of small tumours on mice.
Methods
2D and 3D T2-weighted RARE images of tumour bearing mice were acquired in vivo using a 7 T dedicated animal MR system. For the 3D images the acquired image resolution was varied. The images were exported to a PC workstation where the tumour mass was determined assuming a density of 1 g/cm3, using an in-house developed tool for segmentation and delineation. The resulting data were compared to the weight of the resected tumours after sacrifice of the animal using regression analysis.
Results
Strong correlations were demonstrated between MRI- and necropsy determined masses. In general, 3D acquisition was not a prerequisite for high accuracy. However, it was slightly more accurate than 2D when small (<0.2 g) tumours were assessed for inter- and intraobserver variation. In 3D images, the voxel sizes could be increased from 1603 μm3 to 2403 μm3 without affecting the results significantly, thus reducing acquisition time substantially.
Conclusions
2D MRI was sufficient for accurate tumour size measurement, except for small tumours (<0.2 g) where 3D acquisition was necessary to reduce interobserver variation. Acquisition times between 15 and 50 minutes, depending on tumour size, were sufficient for accurate tumour volume measurement. Hence, it is possible to include further MR investigations of the tumour, such as tissue perfusion, diffusion or metabolic composition in the same MR session.
Zielsetzung: Harmonic Imaging produziert Bilder mit hoher Orts- und Kontrastauflösung. Die Mikrobläschen im verwendeten Kontrastmittel werden deutlich sichtbarer. Ziel dieser Studie war es, das diagnostische Potential der kontrastverstärkten Miktionsurosonographie (MUS) mittels Harmonic Imaging bei reduzierter Kontrastmitteldosis mit der Miktionszystourethrographie (MCU) zu vergleichen. Material und Methodik: 55 Patienten (17 Jungen, 38 Mädchen; Durchschnittsalter 4 Jahre), die zur Refuxuntersuchung kamen, wurden für die Vergleichsstudie rekrutiert. Im Anschluß an einen Standard-Ultraschall des Harntraktes mit Harmonic Imaging (Sonoline Elegra, Siemens) folgte die Blasenkatheterisierung und die intravesikale Gabe des Ultraschallkontrastmittels Levovist® (300 mg/ml). Anstatt der bei MUS mit konventioneller Ultraschallmodalität verwendeten Menge – 10% des Blasenvolumens – wurde jetzt nur 5% Volumen des Kontrastmittels benutzt. Die Sonographie des Harntraktes wurde wiederholt und auch unter Miktion fortgeführt. Es schloss sich ein MCU an. Ergebnisse: Zur Evaluation standen insgesamt 114 Nieren-Ureter-Einheiten (NUE) zur Verfügung. In 29 NUE wurde mit einer oder beiden Methoden ein vesikoureteraler Reflux (VUR) diagnostiziert. In 7 NUE wurde der Reflux nur mit Hilfe der MUS, in 3 NUE nur mittels MCU diagnostiziert. Beim Vergleich der MUS mit der Referenzmethode MCU waren die diagnostischen Ergebnisse folgendermaßen: 86,4% Sensitivität, 92,4% Spezifität, 73,1% positiver Vorhersagewert und 96,6% negativer Vorhersagewert. Der Korrelationskoeffizient zwischen den beiden Methoden betrug 0,741 (p<0,001). Schlußfolgerungen: MUS mit Harmonic Imaging und halbierter Kontrastmitteldosis ist in Bezug auf Ausschluß und Diagnose eines VUR mit der MCU vergleichbar. Die Reduktion der Kontrastmittelmenge schränkt die Aussagefähigkeit der MUS nicht ein, sondern ermöglicht bei gleichen Ergebnissen eine kostengünstigere Untersuchung.
Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with \(^{18}\)F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUV\(_{max}\), SUV\(_{peak}\), SUV\(_{mean}\)) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50%). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUV\(_{max}\) and SUV\(_{peak}\) compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUV\(_{max}\), p = 0.07; SUV\(_{peak}\), p = 0.08). SUV\(_{mean}\) (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in \(^{18}\)F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUV\(_{mean}\) and TL-PSMA in contrast to PSMA-TV.
Rotatorenmanschettenrupturen stellen ein häufig auftretendes Krankheitsbild in der Bevölkerungsgruppe der „Über-40-Jährigen“ dar. Die führenden Methoden in der Diagnostik der Rotatorenmanschette sind neben der klinischen Untersuchung die Kernspintomographie und die Sonographie. Die Aussagekraft beider Methoden wurde im Rahmen von Untersuchungen an präoperativen und postoperativen Patienten verglichen. Die Ergebnisse zeigten eine ausgezeichnete Sensitivität (92,9%) und Spezifität (84,2%) der Sonographie in der Erkennung von Rupturen der Rotatorenmanschette, jedoch eine Abnahme der Sensitivität (71,4%) bei Differenzierung der Läsionen in partielle und komplette Rupturen. Bei der Beurteilung der postoperativen Rotatorenmanschette blieben kleine Läsionen aufgrund der Inhomogenität des Echomusters unerkannt, größere Rerupturen wurden in allen Fällen diagnostiziert. Die Treffsicherheit der Kernspintomographie ergab eine Sensitivität von 78.6% (64,3% bei Differenzierung, s.o.), eine Spezifität von 89,5%, wobei die Untersuchungen an einem Niederfeldgerät (0,2 Tesla) mit im Vergleich zu den in der Schulterdiagnostik standardmäßig eingesetzten Kernspintomographen geringerer Auflösung und verminderter Bildqualität durchgeführt wurden. Innerhalb des ersten postoperativen Jahres erschweren Artefakte die Diagnostik der rekonstruierten Rotatorenmanschette, danach erweist sich die Kernspintomographie als ein überaus spezifisches Verfahren, mit welchem auch kleine Läsionen dargestellt werden. Des Weiteren untersucht vorliegende Arbeit anhand von Patienten- und Probandenkollektiven mit rupturierten und intakten Rotatorenmanschetten, inwieweit sich bei unterschiedlichen Ausmaßen von Rotatorenmanschettenrupturen während einer passiven oder aktiven Abduktion des Armes eine Änderung der Biomechanik feststellen läßt. Bei Untersuchungen an einem offenen Kernspintomographen wurden erstmals Verhältnisse geschaffen, welche die aktive und passive Abduktion des Armes ohne und mit Belastung möglichst realitätsnah simulierten. Die Ergebnisse der dynamischen Untersuchung zeigen, daß Rupturen des M.supraspinatus alleine zu keiner signifikanten Veränderung des Bewegungsablaufs führen. Eine zusätzliche Beteiligung des M.infraspinatus dagegen verursachte sowohl im prä- als auch im postoperativen Kollektiv eine signifikante Verringerung des Subakromialraumes, bei zusätzlicher Belastung in den jeweiligen Abduktionsstellungen zeigte sich keine weitere signifikante Translation. Dies verdeutlicht die Rolle des M.infraspinatus, dessen Funktionsdefizit ein permanentes Höhertreten des Humeruskopfes zur Folge hat. Anhand vorliegender Ergebnisse besteht kein Hinweis auf die Bestätigung der These, biomechanische Veränderungen würden zeitlich vor morphologischen Sehnenläsionen auftreten. Sowohl in der präoperativen Diagnostik als auch in der Beurteilung postoperativer Rotatorenmanschetten besitzt die Kernspintomographie einen herausragenden Stellenwert. Durch die dynamische Untersuchung konnte die oft vernachlässigte Bedeutung des M.infraspinatus hervorgehoben werden, dessen Rekonstruktion bzw. Stärkung anzustreben ist, bevor es zu einer weiteren Störung der Biomechanik kommt. Die dynamische Kernspintomographie stellt somit eine wertvolle Methode zur Untersuchung physiologischer und pathologischer Bewegungsabläufe der Schulter dar.
Es wurden insgesamt 70 Punktionen durchgeführt. Die Patienten waren zwischen 2 und 83 Jahre alt (Durchschnitt 56J.). Das Punktionssystem bestand aus einer Titan-Koaxialnadel und einer ferromagnetischen Punktionsnadel. Der Vorteil dieses Punktionssystems gegenüber einem reinen Titansystem ist die höhere Qualität der Punktionszylinder. Ein Nachteil ist, dass die Punktion außerhalb des MRT-Systems erfolgen muss. Ewa 50% der MRT-gesteuerten Punktionen entfielen auf die Leber. Knochenpunktionen wurden in 21% der Punktionen durchgeführt. Hierzu wurde ein Knochenbiopsieset mit Bohrer benutzt. Die übrigen Punktionen verteilten sich auf Thorax, den Abdominalraum ohne Leber sowie den Kopf/Hals Bereich. Die technische Erfolgsrate lag bei 96%, in drei Fällen war das gewonnene Material nicht repräsentativ, die Sensitivität bestimmte sich mit 88% bei einer Spezifität von 100%. Diese Ergebnisse liegen in der Größenordnung CT- und Ultraschallgesteuerter Punktionen. Berücksichtigt werden muss in diesem Zusammenhang die Tatsache, dass die Indikation zu MRT-gesteuerten Punktionen sich in den meisten Fällen aus der fehlenden Visualisierung der Herdbefunde im CT bzw. der komplexen anatomische Lage ableitete. Hinsichtlich der Komplikationen sind die Ergebnisse vorliegender Studie mit denen CT gesteuerter Punktionen vergleichbar, hier liegt die in der Literatur beschriebene Komplikationsrate CT gesteuerter Punktionen zwischen 1% und 3%. In dem vorliegenden Kollektiv trat lediglich eine konservativ zu beherrschende Blutung bei einer mediastinalen Punktion auf. Vergleicht man die Anzahl richtig positiver Histologien mit denen falsch negativer hinsichtlich der Dauer der Intervention, der Visualisierbarkeit der Läsionen gegeben als der Kontrastunterschied der Läsion zum Umgebungsrauschen (Kontrast/Rausch Verhältnis) sowie hinsichtlich des Kriteriums einer Doppel- oder Einfachangulierung, so zeigten sich keine signifikanten Unterschiede, was erwartungsgemäß in der geringen Anzahl falsch negativer Befunde begründet ist. Ursächlich für falsch negative Befunde waren vielmehr der geringe Durchmesser der Läsionen (4 Herdbefunde < 3 cm) sowie Punktionen im Randbereich maligner Läsionen (N=2).
Studien der letzten Jahre haben gezeigt, dass viele Frauen aufgrund von Schmerzen bzw. aufgrund der Angst vor Schmerzen während der Mammographie diese Kebsvorsorgeuntersuchung nicht wahrnahmen. Die vorliegende Arbeit sollte folgende Fragen klären: Empfinden Frauen bei der Brustkompression während der Mammographie weniger Schmerzen wenn sie ihre Brüste selbst komprimieren, als bei Kompression durch eine MTA? Sind Frauen nach Eigenkompression zufriedener mit der gesamten Mammographie, als Frauen mit Fremdkompression, und inwieweit wirkt sich diese Zufriedenheit auf die Bereitschaft aus, wieder eine Mammographie durchführen zu lassen? Durch diese Studie sollte ein neuer Wege aufgezeigt werden, Frauen die Mammographie so angenehm wie möglich zu gestalten, um dadurch positiven Einfluss auf ihr Verhalten dieser wichtigen Vorsorgeuntersuchung gegenüber nehmen zu können. Untersucht wurden 200 Patientinnen, die der radiologischen Abteilung der Frauenklinik der Universität Würzburg zur Durchführung einer Mammographie zugewiesen worden waren. Es erfolgte die Erhebung der generellen und situativen Ängstlichkeit mittels State-Trait-Angstinventar (STAI), sowie der individuellen Kontrollüberzeugungen mittels Fragebogen zur Erhebung von Kontrollüberzeugungen zu Krankheit und Gesundheit (KKG). Nach der Mammographie beantworteten die Frauen nochmals einen Fragebogen, der ihre Zufriedenheit mit der Mammographie, sowie die dabei empfundenen Schmerzen und die Bereitschaft in zwei Jahren wieder an einem Screening durch Mammographie teilzunehmen, erfasste. Die Ergebnisse der Arbeit lassen sich folgender Maßen zusammenfassen: Es zeigte sich eine Korrelation zwischen der situativen Ängstlichkeit und den bei der Untersuchung empfundenen Schmerzen. Außerdem zeigte sich, je geringer die situationsgebundene Angst der Frauen war, desto zufriedener waren sie auch mit der Untersuchung. Es konnte kein Zusammenhang zwischen der Kontrollüberzeugung und der Zufriedenheit mit der Mammographie nachweisen werden, weder bei Fremdkompression, noch bei Eigenkompression. Auch mit dem bei der Kompression empfundenen Schmerz konnte bei keiner Kontrollüberzeugung ein Zusammenhang hergestellt werden. Bezüglich der Kompression selbst wurde festgestellt, dass Patientinnen der Experimentalgruppe bei der Kompression mehr Kraft anwandten als Patientinnen der Kontrollgruppe und damit ihre Brüste flacher komprimierten. Die Mehrheit beider Gruppen war mit der Mammographie zufrieden und gaben an, wieder an einer Mammographie in zwei Jahren teilnehmen zu wollen. Allerdings waren Frauen, die ihre Brüste selber komprimierten generell zufriedener mit ihrer Untersuchung und empfanden weniger Schmerzen während der Kompression. Der Zusammenhang, dass Frauen eine erneute Teilnahme an einer Mammographie als umso wahrscheinlicher ansahen, je zufriedener sie mit der aktuellen Untersuchung waren, konnte ebenfalls bestätigt werden.
Seit März 2004 ist im Zentrum für operative Medizin der Universitätsklinik Würzburg der Schockraum mit einem Somatom Sensation 16 der Firma Siemens, einem CT mit Sliding-Gantry in Betrieb. Auch schwer verletzte Kinder werden hier nach dem Würzburger Schockraumalgorithmus behandelt. Insgesamt gibt es nur wenige Daten zur Anwendung von GK-CT bei Kindern. Die DGU beschreibt im TraumaRegister die Daten von zuletzt 266 Kliniken. Nur 5,1 % dieser Daten stammen von Kindern unter 16 Jahren. Die Unterschiede zu Erwachsenen entstehen durch die geringere Erfahrung im Straßenverkehr, die kindliche Anatomie, die größere Gefährdung durch den hypovolämischen Schock und die bessere Rekonvaleszenz von Kindern. Ebenso ist die radiologische Diagnostik durch das geringere Körpervolumen und die höhere Strahlenempfindlichkeit der Kinder problematischer. Der Schockraumalgorithmus der Universitätsklinik Würzburg besteht aus der Reanimations-, CT- und Versorgungsphase. Die Indikation zur GK-CT wird nach dem Triage-Schema gestellt und ist auch bei polytraumatisierten Kindern Diagnostik der Wahl. Die Schwere der Verletzungen wird mit dem ISS bestimmt. In den Jahren 2004 bis 2009 wurden 72 Kinder mit Verdacht auf ein Polytrauma behandelt. Davon erhielten 57 (79,2%) ein GK-CT, 15 (20,1 %) erhielten eine organbezogene CT (CCT, Thorax, Abdomen). 15 (26,3 %) der 57 Kinder mit GK-CT hatten retrospektiv kein Polytrauma (ISS < 16), wobei hier von einer Overtriage auszugehen ist. Die Kinder wurden hauptsächlich im Straßenverkehr und hier als Beifahrer eines PKWs verletzt, gefolgt von den Radfahrern und Fußgängern, die von einem PKW erfasst wurden. Ein Drittel der Patienten erlitt Sturzverletzungen aus bis zu fünf Metern Höhe. Die am häufigsten verletzte Körperregion war mit 52,8 % der Kopf, gefolgt vom Thorax, den Extremitäten und 25 % Gesichtsverletzungen. Dies ist durch die ungünstigere Körper-Kopf-Relation der Kinder erklärbar. Im Vergleich zu Erwachsenen ist bei Kindern vermehrt das Gesicht, der Hals und die untere Extremität verletzt, die Wirbelsäule war weniger betroffen. 82 % der Kinder wurden maschinell beatmet, davon 65% initial und 14% in der ZNA. Es wird empfohlen, Kinder frühzeitig zu intubieren, was sich in der Intubationsrate von 82% widerspiegelt. Eine Notfalloperation wurde in 38,9 % der Fälle durchgeführt, wobei es sich hauptsächlich um Frakturrepositionen handelte, vor allem bei Kindern mit ISS < 16. Bei Kindern mit ISS ≥ 16 wurde in 8,8 % der Fälle eine Kraniotomie durchgeführt. Insgesamt wurden 62 % der Kinder operiert, wobei es sich auch bei den Operationen im Verlauf hauptsächlich um Frakturrepositionen handelte. 15 Kinder erhielten kein GK-CT als primäre Diagnostik, obwohl dies retrospektiv gemäß des Triage-Schemas indiziert gewesen wäre. Bei diesen Kindern wurden zusätzlich zum CCT selektive CTs, Röntgenaufnahmen und Abdomenultraschalluntersuchungen durchgeführt. Bei sechs Kindern wurde trotz initialer GK-CT eine therapierelevante Diagnose erst im Verlauf des Klinikaufenthalts gestellt. Dabei handelte es sich um eine Schädelbasis-, eine Orbitaboden-, eine Klavikula-, eine Talusfraktur, ein Mesenterialarterieneinriss und eine Ileumruptur. Ein Kind verstarb, weil dessen Ileumruptur in der radiologischen Diagnostik nicht detektiert wurde und die Zeit bis zur Laparotomie verzögerte. Während des Krankenhausaufenthalts wurde zur Verlaufsdokumentation die Röntgenuntersuchung, gefolgt von der Sonographie, am häufigsten angewendet. Die CT tritt hierbei in den Hintergrund, wobei die MRT häufiger durchgeführt wurde als bei der initialen Diagnostik.
Die Strahlenbelastung des pädiatrischen Kollektivs ist im Kontext der schnellen Diagnoseerhebung therapierelevanter Verletzungen zu sehen. Bei der GK-CT ist mit einem durchschnittlichen DLP von 2268 mGy•cm, bei der CCT von 956 mGy•cm zu rechnen. Bei den Röntgenuntersuchungen ein DFP von 4 cGy•cm2 bei Thoraxröntgenuntersuchungen und 11 cGy•cm2 bei anderen Röntgenuntersuchungen. Zur korrekten Einordnung der Strahlendosis sind genauere Richtwerte für Kinder und genauere Protokolle nötig. Die GK-CT ist Methode der Wahl bei polytraumatisierten Kindern und wird nur in seltenen Fällen von der FAST oder der Röntgenuntersuchung ersetzt. Trotz der GK-CT können nicht alle therapierelevanten Diagnosen gestellt werden. Insgesamt verbrachten die Kinder durchschnittlich 17 Tage im Krankenhaus und sieben Tage auf der Intensivstation. 77,8 % konnten danach nach Hause entlassen werden, sieben Kinder mussten nach dem Krankenhausaufenthalt in eine Rehabilitationsklinik verlegt werden. Die Letalität der Kinder ist mit 10,5% (n=6) im Vergleich zu den Erwachsenen mit 13,5 % und anderen Studien mit einer pädiatrischen Letalität mit durchschnittlich 18 % geringer. Vier Kinder verstarben an schwerem SHT, ein Kind in Folge seines schweren Thoraxtraumas und ein Kind entwickelte eine Sepsis in Folge einer in der radiologischen Diagnostik nicht detektierbaren Ileumruptur.
Die radiologische Diagnostik des kindlichen Polytraumas hat sich durch das MSCT in den letzten Jahren stark gewandelt. Die geringe Letalität unseres Patientenkollektivs ist ein deutlicher Hinweis auf die Effizienz des Würzburger Schockraumalgorithmus auch beim pädiatrischen Polytrauma.
Die farbkodierte Duplexsonographie (FKDS) hat sich als nichtinvasive Methode zur Darstellung des Blutflußes innerhalb von Gefäßen sowie von Gefäßveränderungen etabliert. Während gute Ergebnisse der Farbduplexsonographie in großen Gefäßen über 0,51 mm vorliegen, konnte in einer Modellstudie an kleinen Gefäßen unter 0,51 mm festgestellt werden, daß die FKDS in kleineren Gefäßen systematisch zu niedrig mißt. Mit Hilfe des geprüften Echosignalverstärkers kann dieser systematische Fehler nicht behoben werden. Der Einsatz des Echosignalverstärkers bewirkt grundsätzlich nur eine geringe Zunahme der gemessenen Flußgeschwindigkeit. Dies ist unabhängig von dem Gerätetyp und der Schlauchgröße. Der maximale Effekt wird nach 10 bis 60 Sekunden erreicht. Die Messungen der drei Farbdopplergeräte QAD 1 (Firma Philips/Quantum), SONOLINE Elegra (Firma Siemens) und HDI 3000 (Firma Philips/ATL) unterscheiden sich in ihrer Auswertung signifikant. Die Ursache der großen Messdifferenzen unter den Geräte ist endgültig nicht geklärt. Wahrscheinlich liegt die Ursache in der internen Signalverarbeitung der Farbduplexgeräte.
Die kardiale MRT konnte in dieser Arbeit für die Infarktdiagnostik und Therapiekontrolle erfolgreich eingesetzt werden. Auf Grund einer Vielzahl von Sequenztechniken, dem Vorteil der Nichtinvasivität und dem Fehlen von ionisierenden Strahlen hat sich die MRT zu einem wichtigen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen entwickelt.
Ultra-high-resolution photon-counting detector CT arthrography of the ankle: a feasibility study
(2023)
This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ\(_{50}\); Br98: 39.0, Br84: 22.6, Br76: 16.5 lp/cm). Seven radiologists subjectively assessed the image quality regarding the depiction of bone, hyaline cartilage, and ligaments. An additional quantitative assessment comprised the measurement of noise and the computation of contrast-to-noise ratios (CNR). While an optimal depiction of bone tissue was achieved with the ultra-sharp Br98 kernel (S ≤ 0.043), the visualization of cartilage improved with lower modulation transfer functions at each dose level (p ≤ 0.014). The interrater reliability ranged from good to excellent for all assessed tissues (intraclass correlation coefficient ≥ 0.805). The noise levels in subcutaneous fat decreased with reduced spatial frequency (p < 0.001). Notably, the low-dose Br76 matched the CNR of the full-dose Br84 (p 0.999) and superseded Br98 (p < 0.001) in all tissues. Based on the reported results, a photon-counting detector CT arthrography of the ankle with an ultra-high-resolution collimation offers stellar image quality and tissue assessability, improving the evaluation of miniscule anatomical structures. While bone depiction was superior in combination with an ultra-sharp convolution kernel, soft tissue evaluation benefited from employing a lower spatial frequency.
Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current–time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FD\(_{Ur77}\) and LD\(_{Ur77}\) examinations (p < 0.001) with LD\(_{Ur77}\) scans also providing favorable bone visualization compared to FD\(_{Br69}\) and FD\(_{Br62}\) (p < 0.001). Fleiss’ kappa was 0.618 (0.594–0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.
Die interventionelle Radiologie hat sich in den letzten Jahrzehnten zunehmend auf palliativmedizinische sowie onkologische Bereiche ausgeweitet und kann durch minimal-invasive Therapieoptionen gerade in vulnerablen Patientenkollektiven attraktive Behandlungsmöglichkeiten zur Verfügung stellen. Die tumorbedingte untere Einflussstauung ist ein seltenes Krankheitsbild und stellt eine schwere symptomatische Komplikation einer malignen Grunderkrankung dar. Dabei kommt es im Rahmen dieser Grunderkrankung durch die Primärtumormasse oder Metastasen zu extrinsischer Kompression der Vena cava inferior (VCI), Gefäßinvasion oder Thrombusbildung.
Ziel der Dissertationsarbeit ist es, den technischen und klinischen Erfolg der Sinus-XL ® Stentimplantation in die Vena cava inferior bei einer tumorbedingten unteren Einflussstauung zu untersuchen. Als technischer Erfolg wurde dabei die problemlose Stentimplantation mit anschließender Aufhebung der VCI-Stenose/Okklusion und Revaskularisation der VCI definiert. Bezüglich des klinischen Erfolges wurde der Frage nachgegangen, inwieweit die Stentimplantation die typischen Symptome einer unteren Einflussstauung (Ödeme der unteren Extremität, Aszites und Anasarka) lindern und bestenfalls eliminieren kann. In der vorliegenden Arbeit sind dazu retrospektiv die Daten von insgesamt 21 Patienten (11 Frauen, 10 Männer) mit einem medianen Alter von 61 Jahren (19-92 Jahre), die zwischen Oktober 2010 und Januar 2021 aufgrund einer tumorbedingten unteren Einflussstauung mit einem Sinus-XL ® Stent endovaskulär versorgt wurden, ausgewertet worden. Zur Quantifizierung der klinischen Symptomatik wurde für das jeweilige Symptom ein Scoring-System entwickelt bzw. modifiziert.
Der technische Erfolg belief sich auf 100% (21/21). Postinterventionell konnte zudem eine signifikante Reduktion des transstenotischen Druckgradienten (p = 0,008) und eine signifikante Aufweitung des Stenosendiameters (p < 0,001) erreicht werden. Die primäre und primär-assistierte Stentoffenheit betrug 92,9 % (13/14) und 100% (14/14), die anatomische Stentoffenheit (< 50% Restenose) belief sich auf 53,3 % (8/15). Die Reinterventionsrate lag bei 4,8 % (1/21). Schwerwiegende Komplikationen traten nicht auf. Der klinische Erfolg bezüglich der Ödeme der unteren Extremität belief sich auf 82,4 % (14/17), 93,8 % (15/16) sowie auf 85,7 % (18/21) und zeigte in allen betrachteten Zeitintervallen eine signifikante Scorewertreduktion (p < 0,001). Das klinische Outcome bezüglich der Ödeme war bei kürzeren Stenosen/Obstruktionen signifikant besser (p = 0,025). Bezüglich einer intrahepatischen Segmentbeteiligung, der transstenotischen Druckgradienten, der absoluten Gradientenreduktion sowie der Überlebenszeit nach der Intervention zeigten sich hingegen keine als klinisch relevant einzustufende Ergebnisse. Ein eindeutiger Effekt der Intervention auf die Symptome Anasarka und Aszites konnte nicht nachgewiesen werden. Diesbezüglich zeigten sich klinische Erfolgsraten von 42,9 % (6/14) und 5,3 % (1/19). Im postinterventionellen Verlauf konnten außerdem signifikante Reduktionen der präinterventionellen Harnstoffwerte sowie des Körpergewichtes der Patienten verzeichnet werden.
Zusammenfassend zeigt die vorliegende Arbeit, dass die Sinus-XL ® Stentimplantation geeignet ist, eine tumorbedingte Vena cava inferior-Stenose/Obstruktion aufzuheben und eine Revaskularisation der VCI zu erreichen. Die klinischen Symptome einer unteren Einflussstauung – insbesondere bezogen auf die Ödeme der unteren Extremität und mit Einschränkungen bezogen auf die Symptome Aszites und Anasarka – können ebenfalls durch die Stentimplantation gelindert und teilweise sogar langanhaltend eliminiert werden. Die Sinus-XL ® Stentimplantation sollte daher stets als Therapieoption bei tumorbedingten unteren Einflussstauungen in Erwägung gezogen werden. Nicht zuletzt stellt die Stentimplantation auch eine sichere und komplikationsarme Intervention dar. Weitere Studien, bestenfalls multizentrische Studien, sind jedoch notwendig, um die dargestellten Ergebnisse weiter zu untermauern.
Da die häufigste Ursache der pathologischen Mamillensekretion ein benigner Prozess ist, sollte die Diagnostik mittels nicht invasiver Verfahren im Vordergrund stehen. Dabei stellt die Kernspintomographie eine wichtige Modalität dar, vor allem wenn die Mammographie und die Mammasonographie keine Befunde zeigen. In dieser Studie wurden Patientinnen mit pathologischer Mamillensekretion mittels MR-Mammographie bei 3,0 Tesla und anschließend mittels Galaktographie untersucht.
Von Juli 2009 bis Juni 2012 wurden 50 Patientinnen in die Studie eingeschlossen, die eine pathologische Mamillensekretion zeigten und einer MR-Mammographie bei 3,0 Tesla zustimmten. Bei allen Studienteilnehmerinnen waren sowohl die Mammographie als auch die Mammasonographie negativ oder zeigten einen unklaren Befund. Weitere Einschlusskriterien waren im Normbereich liegende Nieren- und Prolaktinwerte.
Sechs Patientinnen zeigten einen beidseitigen Ausfluss. Hier wurden beide Brüste in die Studie eingeschlossen, so dass insgesamt 56 Fälle mit einem Durchschnittsalter von 51,2 Jahren (Standardabweichung ± 12,8 Jahre, Median 52,5 Jahre) betrachtet wurden. Ältere Patientinnen zeigten dabei häufiger maligne Ursachen als jüngere, ohne Nachweis eines signifikanten Unterschieds (p = 0,272).
Bei der klinischen Untersuchung war in 44,6% (25/56) ein nicht-blutiger und in 55,4% (31/56) ein blutiger Ausfluss erkennbar. Die Inzidenz der Malignität in der Gruppe der blutigen Sekretion war höher (19,4% vs. 8,0%), jedoch nicht signifikant (p = 0,23). In der Literatur wird davon berichtet, dass bei blutigem Ausfluss das Risiko für ein Mammakarzinom höher ist. Es wird aber auch darauf hingewiesen, dass bei einem nicht-blutigen Ausfluss ein Malignom keinesfalls ausgeschlossen werden kann.
Die häufigste Ursache der pathologischen Mamillensekretion war, wie auch in der Literatur berichtet wird, mit 39,4% ein Papillom. Insgesamt wurde in 14,8% ein Malignom nachgewiesen. Dies ist etwas höher als die vergleichbaren Angaben von 2% - 10% in der Literatur.
Es bestand ein signifikanter, direkt proportionaler Zusammenhang zwischen Größe in der MR-Mammographie und Malignität (p = 0,019). Ein Phänomen, das Liberman et al. ebenfalls beschrieben. Sowohl sie als auch Langer et al. empfehlen somit bei Läsionen, die kleiner als 5 mm sind, aufgrund der geringen Malignomrate auf eine Biopsie zu verzichten. Auch in der vorliegenden Studie waren alle Läsionen < 5 mm benigne.
Zwischen der MR-mammographisch geschätzten Größe und der histopathologisch ermittelten Größe konnte eine signifikant hohe Korrelation gezeigt werden (Korrelationskoeffizient nach Pearson 0,095, p < 0,0001). Dabei wurden die Befunde in der Kernspintomographie tendenziell größer dargestellt. Die gleiche Erfahrung machten auch Son et al. und Schouten van der Velden et al..
Die Ergebnisse der MR-Mammographie wurden mit der danach durchgeführten Galaktographie verglichen. Ein wichtiger Nachteil der Galaktographie zeigte sich in der eingeschränkten Durchführbarkeit. In 23,3% konnte diese nicht erfolgreich beendet werden. In der Literatur wird von ähnlichen Prozentsätzen gesprochen. Zusätzlich erzielten wir im Vergleich zur MR-Mammographie sowohl eine geringere Sensitivität (86% vs. 96%) als auch eine niedrigere Spezifität (33% vs. 70%) für die Galaktographie, was sicherlich auch die Schwierigkeit der Unterscheidung zwischen benignen und malignen Befunden bei einer Galaktographie widerspiegelt. Morrogh et al. verglichen die Galaktographie mit der MR-Mammographie bei 1,5 Tesla ebenfalls bei Patientinnen mit pathologischer Mamillensekretion und negativer Standarddiagnostik. Die von ihnen berichtete Sensitivität von 83% für die MR-Mammographie ist vergleichbar mit der der vorliegenden Studie (75%). Bei 1,5 Tesla erreichten sie allerdings nur eine Spezifität von 62%, die geringer ist als die von uns errechnete Spezifität von 88%. Auch andere Studien referieren eine höhere Spezifität bei höherer Feldstärke.
Um dies allerdings aussagekräftig zu zeigen, muss eine intraindividuelle Studie bei 1,5 Tesla und 3,0 Tesla durchgeführt werden.
Zusammenfassend kann man jedoch sagen, dass die Galaktographie durch die nicht invasive, strahlungsfreie MR-Mammographie bei der Untersuchung von Patientinnen mit pathologischer Mamillensekretion ersetzt werden sollte, insbesondere wenn die Standarddiagnostik keine auffälligen Befunde liefern konnte.
Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T
(2019)
Purpose of this work was to assess feasibility of cardiac diffusion tensor imaging (cDTI) at 7 T in a set of healthy, unfixed, porcine hearts using various parallel imaging acceleration factors and to compare SNR and derived cDTI metrics to a reference measured at 3 T. Magnetic resonance imaging was performed on 7T and 3T whole body systems using a spin echo diffusion encoding sequence with echo planar imaging readout. Five reference (b = 0 s/mm\(^2\)) images and 30 diffusion directions (b = 700 s/mm\(^2\)) were acquired at both 7 T and 3 T using a GRAPPA acceleration factor R = 1. Scans at 7 T were repeated using R = 2, R = 3, and R = 4. SNR evaluation was based on 30 reference (b = 0 s/mm\(^2\)) images of 30 slices of the left ventricle and cardiac DTI metrics were compared within AHA segmentation. The number of hearts scanned at 7 T and 3 T was n = 11. No statistically significant differences were found for evaluated helix angle, secondary eigenvector angle, fractional anisotropy and apparent diffusion coefficient at the different field strengths, given sufficiently high SNR and geometrically undistorted images. R≥3 was needed to reduce susceptibility induced geometric distortions to an acceptable amount. On average SNR in myocardium of the left ventricle was increased from 29±3 to 44±6 in the reference image (b = 0 s/mm\(^2\)) when switching from 3 T to 7 T. Our study demonstrates that high resolution, ex vivo cDTI is feasible at 7 T using commercial hardware.
Objectives
The aim of this study was to explore the left ventricular (LV) deformation changes and the potential impact of deformation on outcome in patients with proven light-chain (AL) amyloidosis and LV hypertrophy.
Background
Cardiac involvement in AL amyloidosis patients is associated with poor outcome. Detecting regional cardiac function by advanced non-invasive techniques might be favorable for predicting outcome.
Methods
LV longitudinal, circumferential and radial peak systolic strains (Ssys) were assessed by speckle tracking imaging (STI) in 44 biopsy-proven systemic AL amyloidosis patients with LV hypertrophy (CA) and in 30 normal controls. Patients were divided into compensated (n = 18) and decompensated (n = 26) group based on clinical assessment and followed-up for a median period of 345 days.
Results
Ejection fraction (EF) was preserved while longitudinal Ssys (LSsys) was significantly reduced in both compensated and decompensated groups. Survival was significantly reduced in decompensated group (35% vs. compensated 78%, P = 0.001). LSsys were similar in apical segments and significantly reduced in basal segments between two patient groups. LSsys at mid-segments were significantly reduced in all LV walls of decompensated group. Patients were further divided into 4 subgroups according to the presence or absence of reduced LSsys in no (normal), only basal (mild), basal and mid (intermediate) and all segments of the septum (severe). This staging revealed continuously worse prognosis in proportion to increasing number of segments with reduced LSsys (mortality: normal 14%, mild 27%, intermediate 67%, and severe 64%). Mid-septum LSsys<11% suggested a 4.8-fold mortality risk than mid-septum LSsys≥11%. Multivariate regression analysis showed NYHA class and mid-septum LSsys were independent predictors for survival.
Conclusions
Reduced deformation at mid-septum is associated with worse prognosis in systemic amyloidosis patients with LV hypertrophy.
Die Kombination einer geringen Kontrastmittelmenge (Prä-Bolus) zur Ermittlung und Konstruktion einer Arteriellen Input Funktion, kombiniert mit der Verabreichung eines höher dosierten Kontrastmittel-Bolus zur Darstellung der morphologischen Herzstrukturen bewirkt eine deutliche Verbesserung des Kontrast-Rausch-Verhältnisses bei gleichzeitigem Vermeiden von Sättigungseffekten. Durch die Möglichkeit der Anwendung dieser Technik in Multi Slice MR Imaging Sequenzen empfiehlt sich die neue Prä-Bolustechnik für weitere, zukünftige klinische Studien auf diesem Gebiet.
Purpose
While [\(^{18}\)F]-fluorodeoxyglucose ([\(^{18}\)F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT.
Methods
Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [\(^{18}\)F]FDG and [\(^{68}\)Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUV\(_{max}\)) and peak (SUV\(_{peak}\) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference.
Results
[\(^{18}\)F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([\(^{18}\)F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [\(^{18}\)F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples.
Conclusion
FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted.
Das Kraniopharyngeom ist eine dysontogenetische Mittellinienfehlbildung mit raumforderndem Charakter. Die Ätiopathogenese ist noch ungeklärt. Bildgebende Verfahren (Sonographie, MRT) ermöglichen bereits pränatal eine Diagnostik. Das neonatale Kraniopharyngeom ist sehr selten. Bisher finden sich in der Literatur nur wenige Fallberichte von denen operative Verläufe sowie klinische Langzeitverläufe bekannt sind. Es bleibt eine Kontroverse hinsichtlich Radikalität und Zeitpunkt der Operation, nicht aber dahingehend, dass die operationsmikroskopische Versorgung die Therapie der Wahl des neonatalen Kraniopharyngeoms darstellt. Die Nähe zur hypophysären-hypothalamischen Achse bedingt eine hohe Komorbidität der Kinder prä- und postoperativ.
We describe the case of a 71-year-old Caucasian female with primary disseminated non-small cell cancer of the lung, presented for palliative radiotherapy of metastatic spread to the 9th and 11th thoracic vertebrae without intramedullary growth. Palliative radiotherapy with daily fractions of 3 Gy and a cumulative dose of 36 Gy to thoracic vertebrae 8-12 was performed. The patient received concomitantly 250 mg gefitinib daily. After a latent period of 16 months, the patient developed symptoms of myelitis. Magnetic resonance imaging (MRI) did not reveal any bony or intraspinal tumor progression, but spinal cord signal alteration. No response to steroids was achieved. The neurological symptoms were progressive in August 2013 with the right leg being completely plegic. The left leg was incompletely paralyzed. Deep and superficial sensitivity was also diminished bilaterally. The patient was completely urinary and anally incontinent. Contrary to the clinical findings, a follow-up MRI (July 2013) showed amelioration of the former signal alterations in the spinal cord. The diagnosis of paraneoplastic myelopathy was refuted by a negative test for autologous antibodies. At the last clinical visit in May 2014, the neurological symptoms were stable. The last tumor-specific treatment the patient is receiving is erlotinib 125 mg/d.
We reviewed the literature and found no reported cases of radiation myelopathy after the treatment in such a setting. The calculated probability of such complication after radiotherapy alone is statistically measurable at the level of 0.02%. We suppose that gefitinib could also play a role in the development of this rare complication.
Parathyroid carcinoma (PC) is an orphan malignancy accounting for only ~1% of all cases with primary hyperparathyroidism. The localization of recurrent PC is of critical importance and can be exceedingly difficult to diagnose and sometimes futile when common sites of recurrence in the neck and chest cannot be confirmed. Here, we present the diagnostic workup, molecular analysis and multimodal therapy of a 46-year old woman with the extraordinary manifestation of abdominal lymph node metastases 12 years after primary diagnosis of PC. The patient was referred to our endocrine tumor center in 2016 with the aim to localize the tumor causative of symptomatic biochemical recurrence. In view of the extensive previous workup we decided to perform [18F]FDG-PET-CT. A pathological lymph node in the liver hilus showed slightly increased FDG-uptake and hence was suspected as site of recurrence. Selective venous sampling confirmed increased parathyroid hormone concentration in liver veins. Abdominal lymph node metastasis was resected and histopathological examination confirmed PC. Within four months, the patient experienced biochemical recurrence and based on high tumor mutational burden detected in the surgical specimen by whole exome sequencing the patient received immunotherapy with pembrolizumab that led to a biochemical response. Subsequent to disease progression repeated abdominal lymph node resection was performed in 10/2018, 01/2019 and in 01/2020. Up to now (12/2020) the patient is biochemically free of disease. In conclusion, a multimodal diagnostic approach and therapy in an interdisciplinary setting is needed for patients with rare endocrine tumors. Molecular analyses may inform additional treatment options including checkpoint inhibitors such as pembrolizumab.
Die MRT hat die höchste Detektionsrate der radiologischen Verfahren zur Erkennung einer Knochenmarksinfiltration durch das multiple Myelom. In der vorliegenden Studie hatte die T2-w TIRM Sequenz die höchste Sensitivität. Es konnte jedoch kein signifikanter Unterschied zwischen der T2w-TIRM Sequenz und der T1-w TSE Sequenz festgestellt werden. Die Interobservervarianz war in Sitzung 2 (T2-w TIRM Sequenz) und Sitzung 3 (T2-w TIRM/T1-w TSE/KM +T1-w TSE Sequenz) gleichwertig. Durch Kontrastmittelgabe konnte die Sensitivität nicht signifikant verbessert werden. Zusammenfassend bietet die T2-w TIRM Sequenz die Möglichkeit einer ersten schnellen orientierenden Untersuchung. Für ein detailliertes radiologisches Staging, Grading und zum Therapiemonitoring sollte jedoch weiterhin eine MRT-Untersuchung mit T2-w TIRM/T1-w TSE Sequenz plus zusätzlicher Kontrastmittelzugabe erfolgen.
Das Pankreaskarzinom stellt mit seiner schlechten Prognose und der Schwierigkeit, es in frühem Stadium zu erkennen, eine große Herausforderung für die Medizin dar. Es gibt zahlreiche diagnostische Möglichkeiten für die Detektion und das Staging dieses Malignoms. Hierfür hat sich als Mittel der ersten Wahl in den letzten Jahren die MD-Computertomographie bewährt. Das Ziel dieser Arbeit war es, die Treffsicherheit der Computertomographie für die Detektion als auch für die Einstufung der präoperativen Resektabilität zu bestimmen und herauszufinden, wo Fehlerquellen in der Bildbefundung liegen, um diese in Zukunft verbessern bzw. vermeiden zu können. Hierfür wurden 83 Patienten mit primärem Verdacht auf ein Pankreaskarzinom in die Studie einbezogen und die präoperativ erstellen Bilder retrospektiv befundet. Dabei ergaben sich Werte für die Sensitivität der Tumordetektion von 94 % und für die Spezifität von 43,75 %. Die Sensitivität zur Einschätzung der Resektabiliät eines Pankreaskarzinoms mit Hilfe des CTs in dieser Studie beträgt 64 % und die Spezifität 97,30 %. Die Ergebnisse an der Universität Würzburg sind damit vergleichbar mit den Ergebnissen anderer Untersuchungen an anderen Zentren.
Trotz der hohen Bildqualität der Multidetektorcomputertomographie war es schwierig, eine chronische Pankreatitis von einem Karzinom zu unterscheiden. Besonders wichtig, vor allem in Zusammenarbeit mit der Visceralchirurgie, ist es, präoperativ festzulegen, ob der Tumor noch resektabel ist, um unnötig aufwändige Operationen zu vermeiden und Patienten mit resektablem Tumor die Chance auf eine potentiell kurative Therapie nicht zu verwehren. Ein in der Bildgebung primär irresektabel eingestufter Befund war mit fast 100 % auch tatsächlich irresektabel. Dagegen stellten sich 20 % der initital als resektabel eingestuften Befunde intraoperativ als irresektabel dar. Als Hauptursachen der falsch eingestuften Befunde fanden sich in dieser Studie Probleme in der Detektion eines arteriellen Gefäßbefalls, kleiner Lebermetastasen oder einer Peritonealkarzinose. Zu ähnlichen Ergebnissen kommen auch andere Autoren. Auch in Zukunft wird trotz weiterer technischer Fortschritte in der Schnittbildgebung eine sichere Unterscheidung wahrscheinlich nicht immer möglich sein. Folglich gilt es im präoperativen Staging des Pankreaskarzinoms, größtmögliche Sorgfalt walten zu lassen. Dies beinhaltet, so genau wie möglich, auf Hinweise zur Unterscheidung einer chronischen Pankreatitis, eines Karzinoms und der erwähnten Irresektabilitätskriterien zu achten. So wird im Rahmen, der durch technische Möglichkeiten gegebenen Treffsicherheit, ein Maximum an Genauigkeit sichergestellt.
Objectives: Positron emission tomography (PET) is currently considered the non-invasive reference standard for lymph node (N-)staging in lung cancer. However, not all patients can undergo this diagnostic procedure due to high costs, limited availability, and additional radiation exposure. The purpose of this study was to predict the PET result from traditional contrast-enhanced computed tomography (CT) and to test different feature extraction strategies. Methods: In this study, 100 lung cancer patients underwent a contrast-enhanced \(^{18}\)F-fluorodeoxyglucose (FDG) PET/CT scan between August 2012 and December 2019. We trained machine learning models to predict FDG uptake in the subsequent PET scan. Model inputs were composed of (i) traditional “hand-crafted” radiomics features from the segmented lymph nodes, (ii) deep features derived from a pretrained EfficientNet-CNN, and (iii) a hybrid approach combining (i) and (ii). Results: In total, 2734 lymph nodes [555 (20.3%) PET-positive] from 100 patients [49% female; mean age 65, SD: 14] with lung cancer (60% adenocarcinoma, 21% plate epithelial carcinoma, 8% small-cell lung cancer) were included in this study. The area under the receiver operating characteristic curve (AUC) ranged from 0.79 to 0.87, and the scaled Brier score (SBS) ranged from 16 to 36%. The random forest model (iii) yielded the best results [AUC 0.871 (0.865–0.878), SBS 35.8 (34.2–37.2)] and had significantly higher model performance than both approaches alone (AUC: p < 0.001, z = 8.8 and z = 22.4; SBS: p < 0.001, z = 11.4 and z = 26.6, against (i) and (ii), respectively). Conclusion: Both traditional radiomics features and transfer-learning deep radiomics features provide relevant and complementary information for non-invasive N-staging in lung cancer.
The relation between LV function and cardiac MRI tissue characteristics in separate myocardial segments and their change over time has yet to be explored in myocarditis. Thus, our research aimed to investigate possible associations between global and regional myocardial T1 and T2 times and peak strain in patients with suspected myocarditis.
From 2012 to 2015, 129 patients with clinically suspected myocarditis of the prospective, observational MyoRacer-Trial underwent systematic biventricular EMB at baseline and cardiac MRI at baseline and after three months as a follow-up. We divided the LV myocardium into 17 segments and estimated the segmental myocardial strain using FT. We registered T1 and T2 maps to the cine sequences and transferred the segmentations used for FT to ensure conformity of the myocardial segments. Multi-level multivariable linear mixed effects regression was applied to investigate the relation of segmental myocardial strain to relaxation times and their respective change from baseline to follow-up.
We found a significant improvement in myocardial peak strain from baseline to follow-up (p < 0.001; all p-values given for likelihood ratio tests) and significant associations between higher T1 and T2 times and lower segmental myocardial peak strain (p ranging from < 0.001 to 0.049). E.g., regression coefficient (Reg. coef.) for segmental radial peak strain in short axis view (SRPS_SAX) and T1 time: -1.9, 95% CI (-2.6;-1.2) %/100 ms, p < 0.001. A decrease in T1 and T2 times from baseline to follow-up was also significantly related to a recovery of segmental peak strains (p ranging from < 0.001 to 0.050). E.g., Reg. coef. for SRPS_SAX per ΔT1: -1.8, 95% CI (-2.5;-1.0) %/100 ms, p < 0.001. Moreover, the higher the baseline T1 time, the more substantial the functional recovery from baseline to follow-up (p ranging from 0.004 to 0.042, e.g., for SRPS_SAX: Reg. coef. 1.3, 95% CI (0.4;2.1) %/100 ms, p 0.004). We did not find an effect modification by the presence of myocarditis in the EMB (p > 0.1).
Our cross-sectional and longitudinal analyses provide evidence of dose-dependent correlations between T1 and T2 relaxation times and myocardial peak strain in patients with clinical presentation of myocarditis, regardless of the EMB result. Thus, assessing strain values and mapping relaxation times helps estimate the functional prognosis in patients with clinically suspected myocarditis.
BACKGROUND. Prostate cancer (PCa) remains a major health concern in men of the Western World. However, we still lack effective diagnostic tools a) for an effective screening with both high sensitivity and specificity, b) to guide biopsies and avoid histology sampling errors and c) to predict tumor aggressiveness in order to avoid overtreatment. Therefore, a more reliable, highly cancer-specific and ideally in vivo approach is needed. The present study has been designed in order to further develop and test the method of "metabolomic imaging" using magnetic resonance spectroscopy (MRS) at 7T to address those challenges.
METHODS. Thirty whole prostates with biopsy-proven PCa were in vitro analyzed with a 7T human MR scanner. A voxel grid containing the spectral information was overlaid with the MR image of the middle transverse cross-sectional plane of each case. Subsequent histopathological evaluation of the prostate specimen followed. After the spectral output was processed, all voxels were compared with a metabolomic PCa profile, which had been established within a preliminary study, in order to create a metabolomic map indicating MRS cancer-suspicious regions. Those regions were compared with the histologically identified tumor lesions regarding location.
RESULTS. Sixty-one percent of the histological cancer lesions were detected by metabolomic imaging. Among the cases with PCa on the examined slice, 75% were identified as cancerous. None of the tested features significantly differed between detected and undetected cancer lesions. A defined "Malignancy Index" (MI) significantly differentiated between MRS-suspicious lesions corresponding with a histological cancer lesion and benign lesions (p = 0.006) with an overall accuracy of 70%. The MI furthermore showed a positive correlation with the Gleason grade (p = 0.021).
CONCLUSION. A new approach within PCa diagnostics was developed with spectral analysis including the whole measureable metabolome - referred to as "metabolomics" - rather than focusing on single metabolites. The MI facilitates precise tumor detection and may additionally serve as a marker for tumor aggressiveness. Metabolomic imaging might contribute to a highly cancer-specific in vivo diagnostic protocol for PCa.
Die vorliegende Arbeit hat zum Ziel, den Stellenwert von kontrastverstärkten MR- Sequenzen in der bildgebenden Diagnostik von Hand und Fingern zu untersuchen. Denn trotz einer breiten empirischen Anwendung von gadoliniumhaltigen Kontrastmitteln im europäischen Raum besteht keine ausreichende wissenschaftliche Datengrundlage zur kontrastverstärkten Hand-MRT nach einem Trauma. Zu diesem Zweck wurden zwischen Januar 2016 und August 2018 am Rhön-Klinikum Campus Bad Neustadt 165 MRT-Untersuchungen von distalem Unterarm, Karpus, Metakarpus und/oder Fingern selektiert. Einschlusskriterien waren eine positive Traumaanamnese, standardisierte MRT-Sequenzen und das Fehlen von Kontraindikationen.
Zur Definition eines diagnostischen Referenzstandards wurden alle Fälle vorab durch einen Senior-Investigator mit 36 Jahren Erfahrung in muskuloskelettaler Radiologie analysiert. Für die Bildevaluation wurden aus jeder MRT-Untersuchung zwei Datensätze erstellt, wobei der erste Datensatz nur die nativen Sequenzen (PD / T2 FSE fs und T1 FSE ) und der zweite Datensatz zusätzlich zu eine kontrastverstärkte Sequenz als T1 FSE fs nach Gadolinium-Applikation enthielt. Als Observer fungierten zwei radiologische Fach- bzw. Oberärzte des Universitätsklinikum Würzburgs.
In der vorliegenden Studie wurde ein diagnostisch relevantes Kontrastmittelenhancement an Patienten mit traumatischen Handverletzungen nachgewiesen. Der Kontrastmitteleffekt war mit subjektiven und objektiven Messgrößen statistisch signifikant bei Läsionen der Ligamente und an den ligamentähnlichen Insertionen des ulnaren TFCC-Abschnittes. Als Erklärung für das Kontrastmittelenhancement in der MRT dient in erster Linie die bereits früher beschriebene Hyperämie, die posttraumatisch am Traumaort mit Ausgang von der Synovialis entsteht.
Anhand der Studienergebnisse kann die Empfehlung ausgesprochen werden, in der MRT-Diagnostik von traumatischen Läsionen der Hand immer dann intravenöses Kontrastmittel auf Gadolinium-Basis zu verabreichen, wenn am vermuteten Läsionsort der T2-Kontrast für eine sichere Diagnose unzureichend ist.
Ziel der Arbeit
Die vorliegende Arbeit spiegelt Erfahrungen bezüglich des Einsatzes von Cutting Balloon Kathetern in stenosierten Hämodialyseshunts im Institut für Diagnostische und Interventionelle Radiologie der Universitätsklinik Würzburg wider. Ziel war vor allem die Erfassung der technischen und klinischen Erfolgsrate sowie die Untersuchung der primären Offenheitsraten unter verschiedenen Gesichtspunkten und der Komplikationsrate.
Patienten, Material, Methoden
Zwischen Mai 2006 und Oktober 2010 wurden 44 Interventionen an chronisch niereninsuffizienten Patienten mit stenosierten Dialyseshunts mittels Cutting Balloon Kathetern durchgeführt. Diese wurden retrospektiv ausgewertet.
26 Patienten waren männlich, 18 weiblich. Das Durchschnittsalter zum Zeitpunkt der PTA betrug 66,2 Jahre (±13,3 Jahre). 38 der 44 Patienten erreichten das Follow Up von 450 Tagen.
Bei den Interventionen kamen neben den Peripheral Cutting Balloons® (Boston Scientific Corporation, Natick, MA, USA) (n=45) auch konventionelle Ballonkatheter (n=77) und Hochdruckballonkatheter (n=2) zum Einsatz.
Betrachtet wurden der technische, klinische und hämodynamische Erfolg, die primären Offenheitsraten nach 30, 60 und 180 Tagen unter verschiedenen Gesichtspunkten sowie die Komplikationsrate.
Ergebnisse
In neun Fällen konnte durch die DSA der Nachweis von mehr als einer Stenose ausgemacht werden. Insgesamt wurden 62 Stenosen diagnostiziert, wovon 52 mittels Cutting Balloons behandelt wurden. Die Stenosen, welche mittels Cutting Balloons behandelt wurden, wiesen im Mittel eine Länge von 2,6 cm (±2,1 cm) auf.
Der technische Erfolg lag bei 100%. Die klinische Erfolgsrate lag bei 92,9%. Hämodynamischer Erfolg konnte in 65,9% der Fälle erzielt werden.
Die primäre Offenheitsrate betrug im Mittel 178,2 Tage (±22,8). Sie betrug nach 30 Tagen 88,6%, nach 90 Tagen 68,2% und nach 180 Tagen 36,4%.
Bei den Patienten mit autologen Shunts betrug die primäre Offenheitsrate im Mittel 215,0 Tage (±27,3). Sie betrug in diesem Patientenkollektiv nach 30 Tagen 90,9%, nach 90 Tagen 78,8% und nach 180 Tagen 48,5%.
Bei den Patienten mit alloplastischen Shunts lag die primäre Offenheitsrate im Schnitt bei 67,8 Tagen (±12,0). Sie betrug hier nach 30 Tagen 81,8%, nach 90 Tagen 36,4% und nach 180 Tagen 0%.
Der Unterschied der primären Offenheitsraten war für autologe vs. alloplastische Shunts statistisch signifikant (p=0,002).
Die primäre Offenheitsrate betrug im Mittel bei Patienten mit Diabetes mellitus 248,5 Tage (±42,2). Sie betrug in diesem Patientenkollektiv nach 30 Tagen 88,2%, nach 90 Tagen 76,5% und nach 180 Tagen 52,9%.
Bei Patienten ohne Diabetes mellitus lag die primäre Offenheitsrate im Schnitt bei 133,9 Tagen (±22,7). Sie betrug hier nach 30 Tagen 85,2%, nach 90 Tagen 63,0% und nach 180 Tagen 25,9%.
Der Unterschied der primären Offenheitsraten war bei Diabetikern vs. Nicht-Diabetikern statistisch nicht signifikant.
Die primäre Offenheitsrate betrug im Mittel bei den Patienten mit Dyslipoproteinämie 153,6 Tage (±36,9). Sie betrug in diesem Patientenkollektiv nach 30 Tagen 78,9%, nach 90 Tagen 47,4% und nach 180 Tagen 31,6%.
Bei den Patienten ohne Dyslipoproteinämie lag die primäre Offenheitsrate im Schnitt bei 196,9 Tagen (±28,8). Sie betrug hier nach 30 Tagen 96,0%, nach 90 Tagen 84,0% und nach 180 Tagen 40,0%.
Der Unterschied der primären Offenheitsraten war bei Patienten mit vs. Patienten ohne Dyslipoproteinämie statistisch signifikant (p=0,009).
90,9% der Interventionen (n=40) verliefen komplikationslos. In 9,1% der Fälle (n=4) traten Komplikationen auf, die gemäß den SIR Reporting Standards (62) zu den Minor-Komplikationen zählen.
Fazit
Die PTA mittels Cutting Balloon Katheter stellt bei hohem technischem und klinischem Erfolg sowie niedriger Komplikationsrate eine effektive Behandlungsmethode stenosierter Hämodialyseshunts dar. Weitere Studien werden benötigt, um im Hinblick auf die Kosten-Nutzen-Relation eindeutige Indikationsstellungen für den Einsatz des Cutting Balloons in dysfunktionellen Hämodialyseshunts zu etablieren.
Es wurden Perfusionsmessungen mittels MRT an Infarktpatienten im Akutstadium und im Langzeitverlauf durchgeführt und quantitativ mittels einem Sektormodell ausgewertet. Hierbei zeigte sich, dass sich die Perfusionswerte im Infarktareal und gesunden Myokard nicht signifikant unterschieden und dass sich diese auch im Jahresverlauf nicht signifikant änderten. Es ergab sich auch keine signifikante Korrelation zwischen der Größe des Infarkareales und den gemessenen Perfusionswerten.
Background
In spite of several research studies help to describe the heart in Fabry disease (FD), the cardiomyopathy is not entirely understood. In addition, the impact of blood pressure and alterations in geometry have not been systematically evaluated.
Methods
In 74 FD patients (mean age 36±12 years; 45 females) the extent of myocardial fibrosis and its progression were quantified using cardiac magnetic-resonance-imaging with late enhancement technique (LE). Results were compared to standard echocardiography complemented by 2D-speckle-tracking, 3D-sphericity-index (SI) and standardized blood pressure measurement. At baseline, no patient received enzyme replacement therapy (ERT). After 51±24 months, a follow-up examination was performed.
Results
Systolic blood pressure (SBP) was higher in patients with vs. without LE: 123±17 mmHg vs. 115±13 mmHg; P = 0.04. A positive correlation was found between SI and the amount of LE-positive myocardium (r = 0.51; P<0.001) indicating an association of higher SI in more advanced stages of the cardiomyopathy. SI at baseline was positively associated with the increase of LE-positive myocardium during follow-up. The highest SBP (125±19 mmHg) and also the highest SI (0.32±0.05) was found in the subgroup with a rapidly increasing LE (ie, ≥0.2% per year; n = 16; P = 0.04). Multivariate logistic regression analysis including SI, SBP, EF, left ventricular volumes, wall thickness and NT-proBNP adjusted for age and sex showed SI as the most powerful parameter to detect rapid progression of LE (AUC = 0.785; P<0.05).
Conclusions
LV geometry as assessed by the sphericity index is altered in relation to the stage of the Fabry cardiomyopathy. Although patients with FD are not hypertensive, the SBP has a clear impact on the progression of the cardiomyopathy.
Die Sonographie ist für die Diagnosestellung der Nephrokalzinose Goldstandard. Gerade durch die technische Weiterentwicklung kommen aber immer wieder neue Herausforderungen auf den Untersucher zu. Höhere Frequenzen und dadurch höhere Auflösungen der Bilder führen zu einer häufigeren Darstellung von Veränderungen, die es zu interpretieren gilt. So kommt es bei Nierenuntersuchungen Frühgeborener auffällig oft zu einem Auftreten von Echogenitätsanhebungen, die meist als Nephrokalzinose diagnostiziert werden. Die vorliegende Studie sollte durch Messungen von Helligkeit und Größenverhältnissen, sowie durch Auswertung bestimmter Laborparameter weitere und unabhängigere Kriterien zur Diagnosestellung der Nephrokalzinose finden.
Die Riesenzellarteriitis (RZA) ist in der Altersgruppe der über 50-Jährigen die häufigste idiopathische systemische Vaskulitis. Die Erkrankung bedarf einer zeitnahen Diagnostik und Therapie, um schwere Komplikationen wie eine Erblindung oder einen Schlaganfall zu vermeiden. Die Rezidivneigung erfordert eine mehrjährige, zum Teil lebenslange Glukokortikoid(GC)-Therapie, was das Risiko GC-induzierter Langzeitnebenwirkungen erhöht. Daher wird bei der Mehrzahl der Patienten eine additive GC-einsparende Therapie empfohlen. Hierzu steht der Anti-IL-6-Rezeptor-Antikörper Tocilizumab in subkutaner Applikation als zugelassene Substanz zur Verfügung, alternativ kann Methotrexat (MTX) eingesetzt werden (off-label).