Refine
Is part of the Bibliography
- yes (243)
Year of publication
Document Type
- Journal article (129)
- Doctoral Thesis (112)
- Other (1)
- Preprint (1)
Keywords
- MRI (21)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Herzinfarkt (7)
- Kernspintomografie (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
- Herz (5)
- Herzmuskel (5)
- Kernspintomographie (5)
- Perfusion (5)
- endovascular (5)
- myocardial infarction (5)
- CT angiography (4)
- Fabry-Krankheit (4)
- Hirntumor (4)
- Lunge (4)
- Magnetresonanztomographie (4)
- Ultraschall (4)
- deep learning (4)
- late enhancement (4)
- lung (4)
- multiple myeloma (4)
- rotator cuff (4)
- ultrasound (4)
- CT (3)
- Funktionelle NMR-Tomographie (3)
- Harmonic Imaging (3)
- Herzstoffwechsel (3)
- Interventionsradiologie (3)
- Kinder (3)
- Kontrastmittel (3)
- Koronarperfusion (3)
- MR-Spektroskopie (3)
- Mammographie (3)
- Medizin (3)
- NMR-Bildgebung (3)
- Polytrauma (3)
- Pädiatrie (3)
- Radiologie (3)
- SLOOP (3)
- Spektroskopie (3)
- arthrography (3)
- cardiac magnetic resonance imaging (3)
- children (3)
- computed tomography (3)
- contrast media (3)
- diagnosis (3)
- giant cell arteritis (3)
- heart (3)
- liver (3)
- machine learning (3)
- magnetic resonance (3)
- myocardial perfusion (3)
- myocardium (3)
- pulmonary embolism (3)
- quantification (3)
- radiography (3)
- radiology (3)
- radiomics (3)
- spectroscopy (3)
- stroke (3)
- 18F-FDG PET/CT (2)
- 31P-MRS (2)
- AMADEUS (2)
- ATP (2)
- Absolutquantifizierung (2)
- Aortenklappenersatz (2)
- Aortenstenose (2)
- Appendizitis (2)
- Bildqualität (2)
- Computed tomography (2)
- Cystic fibrosis (2)
- DW-MRI (2)
- DWI (2)
- Diffusions-MRT (2)
- Diffusionsgewichtete Magnetresonanztomographie (2)
- Dosisreduktion (2)
- Dual-Source-Computertomographie (2)
- Echtzeit (2)
- Fabry disease (2)
- Hand (2)
- Heart (2)
- Interventionelle Radiologie (2)
- Late Enhancement (2)
- Leber (2)
- Leberzirrhose (2)
- Lungenembolie (2)
- MUS (2)
- Medulloblastom (2)
- Myocardial infarction (2)
- Myokardinfarkt (2)
- NMR-Mammographie (2)
- NMR-Spektroskopie (2)
- PET/CT (2)
- Periphere arterielle Verschlusskrankheit (2)
- Punktion (2)
- Rotatorenmanschette (2)
- Sauerstoff (2)
- Schockraumalgorithmus (2)
- Schulter (2)
- SonoVue (2)
- Stent (2)
- TFCC (2)
- VUR (2)
- Wertigkeit (2)
- X-ray computed (2)
- acute myocardial infarction (2)
- aneurysms (2)
- angiography (2)
- aorta (2)
- aortic stenosis (2)
- blood flow (2)
- bone (2)
- cardiac (2)
- cardiac spectroscopy (2)
- cartilage (2)
- case report (2)
- central nervous system (2)
- cystic fibrosis (2)
- data acquisition (2)
- dose reduction (2)
- dual-energy CT (2)
- echocardiography (2)
- elbow joint (2)
- endovascular therapy (2)
- first pass (2)
- follow-up (2)
- harmonic imaging (2)
- imaging (2)
- interventional radiology (2)
- joint instability (2)
- knee (2)
- lesions (2)
- mammography (2)
- microvascular obstruction (2)
- mikrovaskuläre Obstruktion (2)
- mouse (2)
- muscle degeneration (2)
- no reflow (2)
- outcome (2)
- oxygen-enhanced (2)
- pattern (2)
- perfusion (2)
- preclinical research (2)
- prostate cancer (2)
- recurrence (2)
- relapse (2)
- renal artery (2)
- rotator cuff tear (2)
- shoulder (2)
- shoulder surgery (2)
- skull (2)
- therapy (2)
- tomography (2)
- translational research (2)
- tumor (2)
- wrist (2)
- 0 (1)
- 0.2 Tesla (1)
- 11C-Methionine PET/CT (1)
- 13C-Methacetin-Atemtest (1)
- 1H-Magnetic resonance spectroscopy (1H-MRS) (1)
- 2 Tesla (1)
- 2-dimensional speckle tracking (1)
- 2D-SPLASH (1)
- 2D-perfusion angiography (1)
- 3 Tesla (1)
- 3,0 Tesla (1)
- 3.0 Tesla (1)
- 31-P-MR-Spectroskopie (1)
- 31-P-Magnetresonanztomographie (1)
- 31P (1)
- 31P-MR-Spectroscopy (1)
- 31P-MR-Spektroskopie (1)
- 31P-MR-spectroscopy (1)
- 3D printing (1)
- 3D-CSI (1)
- 3 T (1)
- 4D flow cardiovascular magnetic resonance (1)
- 4D-MRI (1)
- 68Ga-Pentixafor PET/CT (1)
- 7 T (1)
- 7T (1)
- ADC (1)
- AMARES (1)
- ASE formula (1)
- ATRT (1)
- AW-CSI (1)
- Abdomen (1)
- Absolutkonzentrationen (1)
- Abszess (1)
- Acoustic radiation force imaging (ARFI) (1)
- Adaptive cell transfer (1)
- Adenosin (1)
- Akromioklavikulargelenk (1)
- Akute Extremitätenischämie (1)
- Alter (1)
- Amputation (1)
- Anderson-Fabry Disease (1)
- Aneurysma (1)
- Aneurysmen (1)
- Angiographie (1)
- Angioplastie (1)
- Anisotrope Diffusion (1)
- Aortic Valve Replacement (1)
- Applied physics (1)
- Arterial Diameters (1)
- Arterien (1)
- Arthrography (1)
- Arthroskopie (1)
- Atherosklerose (1)
- Atmung (1)
- Atrophie (1)
- Auswertung (1)
- B (1)
- B0 correction (1)
- B0-Korrektur (1)
- BM (1)
- BMI (1)
- BOLD (1)
- BPD (1)
- Bauchspeicheldrüsentumor (1)
- Beckengefäße (1)
- Beingefäße (1)
- Bestimmung des Relaxations-Parameters in der Magnetresonanztomografie (1)
- Bewegungsfixateur (1)
- Bilderzeugung (1)
- Biliary (1)
- Biomedical engineering (1)
- Biopsie (1)
- Bizepssehnenpathologie (1)
- Blutflussgeschwindigkeit (1)
- Bluthochdruck (1)
- Bolustriggerung (1)
- Breiter Rückenmuskel (1)
- Brustkompression (1)
- Bänder (1)
- CCS (1)
- CD38 (1)
- CINE (1)
- CMR (1)
- CMV (1)
- CRC (1)
- CT perfusion (1)
- CT-angiography (1)
- CT-gesteuerte Punktion (1)
- CTNNB1 (1)
- Cancellous bone (1)
- Carcinomatosis (1)
- Cardiac magnetic resonance imaging (1)
- Cardiac ventricles (1)
- Cardiomyopathy (1)
- Cardioperfusion (1)
- Children (1)
- Cisplatin (1)
- Clinical Genetics (1)
- Cold pressure test (1)
- Computed axial tomography (1)
- Computer-aided diagnosis (1)
- Computertomografie (1)
- Computertomograph (1)
- Computertomographie Angiographie (1)
- Computertomography Angiography (1)
- Cone-beam computed tomography (1)
- Convolutional Neural Network (1)
- Crohn’s disease (1)
- Cushing’s disease (1)
- Cushing’s syndrome (1)
- Cystic fibrosis liver disease (CFLD) (1)
- Cystische Fibrose (1)
- D313Y genotype (1)
- DCIS (1)
- DCM (1)
- DIPG (1)
- DM (1)
- DSA (1)
- DTI (1)
- Darmsonographie (1)
- Data acquisition (1)
- Datenbank (1)
- Deep learning (1)
- Definition (1)
- Delayed Enhancement (1)
- Density Weighting (1)
- Desmoplakin (1)
- Diagnose (1)
- Diagnostic medicine (1)
- Diagnostik (1)
- Dichtegewichtete Bildgebung (1)
- Dichtegewichtung (1)
- Differentialdiagnose (1)
- Diffusion (1)
- Diffusion Tensor Imaging (1)
- Diffusion tensor imaging (1)
- Diffusionsgewichtete Bildgebung (1)
- Digitale Subtraktionsangiographie (1)
- Digitalisierung (1)
- Divertikulitis (1)
- Donor lymphocytes (1)
- Doppelkontrastpharyngographie (1)
- Dopplersonographie (1)
- Drainage (1)
- Dual-Source Computertomography (1)
- Duplexsonographie (1)
- EULAR guidelines (1)
- EVT (1)
- Echo Planar Imaging (1)
- Echo planar imaging (1)
- Echogenität (1)
- Echoplanar-Bildgebung (1)
- Echoplanare Bildgebung (1)
- Echosignalverstärker (1)
- Eigenvectors (1)
- Elastographie (1)
- Elbow (1)
- Elbow joint (1)
- Ellenbogengelenk (1)
- Embolisation (1)
- Entwicklung (1)
- Exercise capacity (1)
- Experimentelle Bildgebung (1)
- Experimentelle allergische Neuritis (1)
- Extracellular volume (1)
- Extracorporeal membrane oxygenation (1)
- Fabry cardiomyopathy (1)
- Fabry nephropathy (1)
- Fabry-associated pain (1)
- Farbduplexgeräte (1)
- Fats (1)
- Feldstärke (1)
- Fett (1)
- Fibrose (1)
- First pass (1)
- Flow (1)
- Fluss (1)
- Flußgeschwindigkeit (1)
- Friedreich's Ataxia (1)
- Friedreich-Ataxie (1)
- Frühgeborenes (1)
- Frühphase (1)
- Funktionelle Kernspintomografie (1)
- Funktionsanalyse <Medizin> (1)
- GCA (1)
- GFAP (1)
- Galaktographie (1)
- Galle (1)
- Gallengangsstenose (1)
- Ganzkörpercomputertomographie bei Kindern (1)
- Gefäßverschluss (1)
- Gehirn (1)
- Gelatineschwamm (1)
- Gelenkinstabilität (1)
- Geschlecht (1)
- Gesicht (1)
- Gesundheits-App (1)
- Giant cell arteritis (GCA (1)
- Glukokortikoide (1)
- Glukokortikoideinsparende Therapie (1)
- HMDP hydroxymethylene diphosphonate (1)
- Heartdisease (1)
- Hepatozelluläres Karzinom (1)
- Herzerkrankung (1)
- Herzfunktion (1)
- Herzmetabolismus (1)
- Herzmuskelkrankheit (1)
- Herzwandbewegung (1)
- Hochfeld (1)
- Hypertrophische Herzmuskelkrankheit (1)
- Hyperämie (1)
- Hypophyse (1)
- Hypophysenhormon (1)
- ICRS (1)
- ISS (1)
- Image Quality (1)
- Imaging (1)
- Imaging techniques (1)
- Immunotherapy (1)
- Inflammatory diseases (1)
- Informationsverarbeitung (1)
- Interventional radiology (1)
- Interventionen (1)
- Intrakranielles Aneurysma (1)
- Intravenöse Applikation (1)
- JCV (1)
- Juvenile biventricular cardiomyopathy (1)
- KOOS (1)
- Karpus (1)
- Kinderheilkunde (1)
- Kinderradiologie (1)
- Kindesalter (1)
- Kleinhirntumor (1)
- Kohlenstoff-13-Exhalationstest (1)
- Komplikation (1)
- Konservative Therapie (1)
- Korrelation (1)
- Kraniopharyngeom (1)
- Kraniostenose (1)
- Krebsvorsorge (1)
- Kritische Extremitätenischämie (1)
- Künstliche Intelligenz (1)
- L-arginine (1)
- Langzeitergebnisse (1)
- Large vessel vasculitides (LVV) (1)
- Late Gadolinium Enhancement (1)
- Lebensqualität (1)
- Leberfibrose (1)
- Leberfunktion (1)
- Lebertumor (1)
- Lebertumore (1)
- Lebertumoren (1)
- Leberversagen (1)
- Leberzellkrebs (1)
- Levovist (1)
- Literatur (1)
- Liver CT (1)
- Lung (1)
- Lung disease, (1)
- Lungenfunktionsdiagnostik (1)
- Lymphogranulomatose (1)
- M2 (1)
- MCU (1)
- MDCT (1)
- MOLLI (1)
- MOR202 (1)
- MPI (1)
- MPI <Bildgebendes Verfahren> (1)
- MR (1)
- MR angiography (1)
- MR arthrography (1)
- MR guided biopsy (1)
- MR-Arthrographie (1)
- MR-Spectroscopie (1)
- MR-Tomographie (1)
- MR-Urography Pediatric (1)
- MR-spectroscopy (1)
- MRI spectroscopy (1)
- MRT-Tomographie (1)
- MS (1)
- Magnetic Particle Imaging (1)
- Magnetic Resonance Relaxometry (1)
- Magnetic Resonance Spectroscopy Imaging (1)
- Magnetic resonance (three dimensional) (1)
- Magnetic resonance imaging (1)
- Magnetic resonance imaging(MRI) (1)
- Magnetpartikelbildgebung (1)
- Magnetresonanz (1)
- Magnetresonanz-Enterographie (1)
- Magnetresonanz-Relaxometrie (1)
- Magnetresonanzangiographie (1)
- Makrophage (1)
- Maligne Tumoren (1)
- Mamillensekretion (1)
- Mamma (1)
- Marfan syndrome (1)
- Maschinelles Lernen (1)
- Mastoid process (1)
- Medizinische Radiologie (1)
- Medulloblastoma (1)
- Meningeose (1)
- Meningeosis (1)
- Merkel cell carcinoma (1)
- Messprozess (1)
- Metabolomic Imaging (1)
- Metabolomics (1)
- Metastase (1)
- Methotrexat (1)
- Methotrexate (1)
- Mikrosomale Leberfunktion (1)
- Mikrovaskuläre Obstruktion (1)
- Miktionsurosonographie (1)
- Miktionszystourethrographie (1)
- Mitoxantron (1)
- Mitoxantrone (1)
- Model Based Reconstruction Algorithms in Magnetic Resonance Imaging (1)
- Modellbasierte-Rekonstruktionsalgorithmen in der Magnetresonanztomografie (1)
- Molecular imaging (1)
- Morbus Crohn (1)
- Morphing (1)
- Morphologie (1)
- Mukoviszidose (1)
- Multidetector computed tomography (1)
- Multiples Myelom (1)
- Multivoxel (1)
- Muscle function (1)
- Muscle power (1)
- Muskelatrophie (1)
- Muskelverfettung (1)
- Myeloma (1)
- Myokardfibrose (1)
- Myokardiale Perfusion (1)
- Myokardperfusion (1)
- NIHSS (1)
- NMR relaxation (1)
- NR3C1 (1)
- Natrium (1)
- Navigator (1)
- Nephrokalzinose (1)
- Nervenfaser (1)
- Neugeborenes (1)
- Neuroblastom (1)
- Neurochirurgie (1)
- NfL (1)
- Nichtionisches Kontrastmittel (1)
- Nierenarterie (1)
- Nierenarterien (1)
- Non-rigid image registration (1)
- Notfallmedizin (1)
- Off.Resonanzen (1)
- Onkologie (1)
- Optimierung (1)
- Organfilter (1)
- Orthopädische Chirurgie (1)
- PCI (1)
- PCr (1)
- PEFB (1)
- PET (1)
- PLAG1 rearrangement (1)
- PML (1)
- PMR (1)
- PNET (1)
- PROM (1)
- PROMM (1)
- PSMA (1)
- PSMA-RADS (1)
- PTA (1)
- Palmoplantar keratoderma (1)
- Pancreas CT (1)
- Pankreaskarzinom (1)
- Pankreaskarzinom präoperativ (1)
- Parallele Bildgebung (1)
- Paralleler Prozess (1)
- Perfusions-CT (1)
- Perfusionscomputertomographie (1)
- Peripheral Artery Disease (1)
- Peripheres Nervensystem (1)
- Perkutane transhepatische Cholangiodrainage (1)
- Perkutane transluminale Angioplastie (1)
- Pharynx (1)
- Phasecontrast Imaging (1)
- Phasenkontrast (1)
- Phasenkorrektur (1)
- Phosphor (1)
- Phosphor-31-NMR-Spektroskopie (1)
- Phosphormetaboliten (1)
- Phosphorylation (1)
- Planimetrie (1)
- Plasmozytom (1)
- Plattform (1)
- Pneumothorax (1)
- Point Spread Function (1)
- Positron emission tomography (1)
- Primary hyperparathyroidism (pHPT) (1)
- Prodigy (1)
- Prostatakrebs (1)
- Prostate cancer diagnostics (1)
- Protonen-MR-Spektroskopie (1)
- Protonen-NMR-Spektroskopie (1)
- Prä-Bolus Untersuchung (1)
- Präbolus (1)
- Präbolus Technik (1)
- Pyramidenbahn (1)
- Quantitativ (1)
- Quantitative 31P-MR- Spektroskopie (1)
- Quantitative Sonoelastographie (1)
- ROC-Kurve (1)
- Radiation exposure (1)
- Radiologische Diagnostik (1)
- Radiotherapy treatment planning (1)
- Raumforderung (1)
- Read-out (1)
- Relaxation Parameter Mapping in Magnetic Resonance Imaging (1)
- Respiratory induced tumor motion (1)
- Rezidiv (1)
- Rezidivmuster (1)
- Riesenzellarteriitis (1)
- Rotatorenmanschettenläsion (1)
- Rotatorenmanschettenruptur (1)
- Röhrenstromanpassung (1)
- SASHA (1)
- SL-Band (1)
- SLAP-Läsion (1)
- SLAP-lesion (1)
- SP-fixation (1)
- SPECT (1)
- SPIO-Partikel (1)
- ST-elevation myocardial infarction (1)
- STEMI (1)
- Scar (1)
- Schmerz (1)
- Schneideballon (1)
- Schockraumbehandlung (1)
- Segmentation (1)
- Sensitivität (1)
- Sequenzvergleich (1)
- Severely injuried child (1)
- ShMOLLI (1)
- Shuntstenose (1)
- Sigmadivertikulitis (1)
- Single-Source-Dual-Energy-CT (1)
- Singlevoxel (1)
- Soft tissues (1)
- Somatostatin receptor expression (1)
- Sonographie (1)
- Spezifität (1)
- Spiral-CT (1)
- Spiral-Computertomographie (1)
- Split-Filter-Dual-Energy-CT (1)
- Staging (1)
- Stanzbiopsie (1)
- Stentfracture (1)
- Stentfraktur (1)
- Stichkanalembolisation (1)
- Strahlendosis (1)
- Strahlenexposition (1)
- Strahlenschutz (1)
- Stress (1)
- Strukturwandel (1)
- Störabstand (1)
- Subarachnoidalblutung (1)
- Swine (1)
- T1 mapping (1)
- T1-Mapping (1)
- TPM (1)
- Tagging (1)
- Teichholz formula (1)
- Tesla (1)
- Therapie (1)
- Tissue Phase Mapping (1)
- Tocilizumab (1)
- Tomography (1)
- Tractography (1)
- Transarterielle Chemoembolisation (1)
- Transluminale Angioplastie (1)
- Trauma (1)
- Traveling Wave Magnetic Particle Imaging (1)
- Triangular fibrocartilage (1)
- Triangulärer fibrokartilaginärer Komplex (1)
- Tumor (1)
- Tumorentdeckungsrate (1)
- Turbo Spin Echo (1)
- US (1)
- USP28 (1)
- USP8 (1)
- Ultraschall-Elastographie (1)
- Ultraschallkontrastmittel (1)
- Ultrasound (1)
- VCUG (1)
- VIDE (1)
- VIDED (1)
- VUS (1)
- Vakuumstanzbiopsie (1)
- Vascular closure devices (1)
- Vasculitis (1)
- Vaskuläre Rekonstruktion (1)
- Vasospasm (1)
- Vasospasmen (1)
- Vena cava inferior (1)
- Ventilation (1)
- Ventricular septal rupture (1)
- Vergleich konservative digitale Röntgentechnik (1)
- Verlgeich (1)
- Vitalitätsdiagnostik (1)
- Wernicke's perpendicular fasciculus (1)
- Wernickes Assoziationsbündel (1)
- Whole-body-computertomography (1)
- Wrist (1)
- X-ray radiography (1)
- Zangenbiopsie (1)
- Zentralnervensystem (1)
- [18F]FDG PET/CT (1)
- [18F]FDG-PET-CT (1)
- \(^{18}\)F-PSMA-1007 (1)
- abdominal lymph node metastases (1)
- abdominale Bildgebung (1)
- abscess (1)
- absolute metabolite concentrations (1)
- ac-joint (1)
- access site complications (1)
- acute lower-extremity ischemia (1)
- adjunctive endovascular procedures (1)
- adolescents (1)
- adrenocortical (1)
- age dependency (1)
- akuter Myokardinfarkt (1)
- algorithms (1)
- alkaline phosphatase (1)
- amyloidosis (1)
- aneurysmal subarachnoid hemorrhage (1)
- angioplasty (1)
- animal model (1)
- ankle (1)
- anorectal angl (1)
- antegrade puncture (1)
- aortal valve stenosis (1)
- aortic dissection (1)
- apolipoprotein-E (1)
- appendicitis (1)
- arteria femoralis superficialis (1)
- arteria poplitea (1)
- arteriitis temporal arteriitis (1)
- arthroscopy (1)
- artificial intelligence (1)
- asfotase alfa (1)
- aspiration (1)
- association (1)
- atheriosclerosis (1)
- atherosclerosis (1)
- atrophy of muscles (1)
- atypical (1)
- atypical teratoid/rhabdoid tumor (1)
- atypischer teratoid/rhabdoider Tumor (1)
- auditiver Kortex (1)
- auditory cortex (1)
- biliäre Stenose (1)
- biliäre Striktur (1)
- biomedical engineering (1)
- bisphosphonates (1)
- bladder cancer (1)
- blade angioplastie (1)
- blood coagulation factor XIII (1)
- bolus tracking (1)
- bone biology (1)
- bone bruise (1)
- bone fractures (1)
- bone marrow edema (1)
- bone marrow lesion/edema (1)
- bone remineralization (1)
- bone replacement material (1)
- bone-marrow (1)
- bowel sonography (1)
- brain metastases (1)
- brainstem glioma (1)
- breast (1)
- breast cancer (1)
- breast cancer imaging (1)
- c-reactive protein (1)
- cable-clamp implants (1)
- cancellous bone (1)
- cancer (1)
- cancer detection rate (1)
- cancer imaging (1)
- cancer screening (1)
- carcinoma (1)
- carcinoma metastases to pancreas (1)
- cardiac MRI (1)
- cardiac breathing (1)
- cardiac function (1)
- cardiac imaging (1)
- cardiac infarction (1)
- cardiac magnetic resonance (1)
- cardiac metabolism (1)
- cardiac transplantation (1)
- cardiomyopathy (1)
- cardiovascular MRI (1)
- cardiovascular magnetic resonance (1)
- cardiovascular magnetic resonance (CMR) (1)
- cartilage defect (1)
- central venous catheter (1)
- cerebral arteries (1)
- cerebral metastases (1)
- cerebrospinal fluid (1)
- cervical vertebrae pneumatization (1)
- chemotherapy (1)
- chiasma antebrachii (1)
- chondral defect (1)
- chronic mesenteric ischemia (1)
- chronisch-entzündliche Darmerkrankung (1)
- cine loop (1)
- cirrhosis (1)
- classification (1)
- clinical manifestations (1)
- cold pressor test (1)
- color-coded (1)
- color-coding (1)
- colorectal cancer (1)
- complication aortic-aneurysm (1)
- computational neural networks (1)
- computed tomography angiography (CTA) (1)
- concomitant radiotherapy (1)
- cone-beamcomputed tomography (1)
- constrastagent (1)
- continuous extracorporeal femoral perfusion model (1)
- contrast agent (1)
- contrast agents (1)
- contrast medium (1)
- contrast-enhanced (1)
- contrast-enhanced ultrasound (1)
- conventional imaging (1)
- convolution kernel (1)
- convolutional neural network (1)
- convolutional neural networks (1)
- coracohumeral distance (1)
- coracohumeral impingement (1)
- coronary arteries (1)
- corpus cavernosum (1)
- correction (1)
- correlation (1)
- corticosteroid treatment (1)
- cranial (1)
- craniopharyngioma (1)
- cross-sectional imaging (1)
- ct-scan (1)
- cutting balloon (1)
- daratumumab (1)
- data base (1)
- database (1)
- deformation (1)
- delayed enhancement (1)
- density (1)
- density weighted imaging (1)
- density weighting (1)
- deterministic (1)
- diagnostics (1)
- diffus intrinsisches Ponsgliom (1)
- diffusion tractography (1)
- diffusion weighted mri (1)
- diffusion-weighted MRI (1)
- digital subtraction angiography (1)
- digital subtraction angiography (DSA) (1)
- digital transformation (1)
- disease (1)
- distal occlusion (1)
- dorsal instrumentation (1)
- double-blind (1)
- double-contrast pharyngography (1)
- drainage-treatment (1)
- drillability (1)
- drug-eluting beads (1)
- dual-energy (1)
- dual-energy computed tomography (1)
- dual-room trauma suite (1)
- dual-room whole-body CT (1)
- dual-source CT (1)
- duktal (1)
- dynamic (1)
- dynamisch (1)
- echo planar imaging (1)
- echogenicity (1)
- ejection fraction (1)
- electrical and electronic engineering (1)
- embolism/thrombosis (1)
- encephalitis (1)
- endothelium (1)
- endovascular repair (1)
- endovascular treatment (1)
- endovaskulär (1)
- endovaskuläre Therapie (1)
- enhancement (1)
- epicondyles (1)
- erythrocyte sedimentation-rate (1)
- evaluation (1)
- experimental imaging (1)
- experimental models of disease (1)
- exposure of radiation (1)
- extramedullary hematopoiesis (1)
- extremities (1)
- extremity trauma (1)
- fMRT (1)
- fabry's disease (1)
- face morphing (1)
- facial age (1)
- facial gender (1)
- farbkodierte DSA (1)
- fatty degeneration (1)
- fatty infiltration (1)
- femoral access (1)
- femoral arteries (1)
- fenestration (1)
- fibre tracking (1)
- fibroblast activation protein (1)
- fibrosis (1)
- flexor digitorum superficialis (1)
- flexor tendon (1)
- flow patterns (1)
- fluoroscopy (1)
- forearm (1)
- fracture (1)
- fracture-associated vascular damage (1)
- fractures, bone (1)
- fragility fracture (1)
- free respiration (1)
- free‐breathing (1)
- freie Atmung (1)
- functional MRI (1)
- functional analysis (1)
- functional imaging (1)
- functional magnetic resonance imaging (1)
- g-factor (1)
- gadoliniumhaltiges Kontrastmittel (1)
- galaoctography (1)
- gefitinib (1)
- gelatin sponge (1)
- gender (1)
- general anaesthesia (1)
- glial damage (1)
- glial fibrillary acidic protein (1)
- glucocorticoid excess (1)
- glucocorticoid-sparing agents (1)
- glucocorticoids (1)
- goutallier (1)
- gradient impulse response function (1)
- gradient system respose (1)
- gradient system trasfer function (1)
- grading system of chondral defects (1)
- harmonische Bildgebung (1)
- head and neck (1)
- head and neck cancer (1)
- healing and remodelling processes (1)
- heart metabolism (1)
- hemodialysis (1)
- hemodynamics (1)
- hepatocellular carcinoma (1)
- hepatocellular carcinoma (HCC) (1)
- hepatozelluläres Karzinom (HCC) (1)
- high blood pressure (1)
- high risk (1)
- high tibial osteotomy (1)
- high-energy-phosphate metabolism (1)
- hinged external fixator (1)
- hodgkin's lymphoma (1)
- hypercortisolism (1)
- hypertrophic cardiomyopathy (1)
- hypophosphatasia (1)
- identification (1)
- idiopathic fecal incontinence (1)
- image analysis (1)
- image processing (1)
- image quality (1)
- image segmentation (1)
- imaging techniques (1)
- immune check inhibitor (1)
- impact (1)
- in vivo imaging (1)
- infarction size (1)
- inferior vena cava (1)
- infiltrate (1)
- inflammation (1)
- inherited metabolic disorders (1)
- interventional procedures (1)
- interventional therapy (1)
- interventionelle Radiologie (1)
- interventionelle Therapie (1)
- intracranial (1)
- intracranial lesions (1)
- intracranial tumors (1)
- intrakraniell (1)
- intrakranielle Läsionien (1)
- intrakranielle Tumoren (1)
- intramyokardiale Einblutung (1)
- intravascular ultrasound (IVUS) (1)
- intravenös (1)
- ionizing radiation (1)
- ischemic stroke (1)
- juvenile idiopathic arthritis (1)
- ketogenic diet (1)
- ketone bodies (1)
- kranial (1)
- large animal models (1)
- large vessel occlusion (1)
- large-vessel vasculitis (1)
- late gadolinium-enhancement (1)
- late thrombectomy (1)
- left lateral wall (1)
- left ventricular hypertrophy (1)
- left ventricular mass index (1)
- level of evidence: IV (1)
- ligaments (1)
- lipoblastoma (1)
- literature (1)
- livertumour (1)
- local point-spread function (1)
- long-term results (1)
- lower extremity (1)
- lymphatic metastasis (1)
- magnesium phosphate cement (1)
- magnetic particle imaging (1)
- magnetic resonance (vascular studies) (1)
- magnetic resonance imaging MRI (1)
- maligne untere Einflussstauung (1)
- mammographic compression (1)
- matched filters (1)
- mechanical thrombectomy (1)
- medical research (1)
- medulloblastoma (1)
- mesenteric stenting (1)
- meta-analysis (1)
- metabolic profile (1)
- metabolism (1)
- mice (1)
- mikrochirurgische Resektion (1)
- minimal invasive surgery (1)
- minimalinvasiv (1)
- molecular diagnostics (1)
- molecular imaging (1)
- motor cortex (1)
- movable sliding gantry (1)
- mr spectroscopy (1)
- mrs (1)
- multiparametric CT (1)
- multiples myeloma (1)
- multivoxel (1)
- musculoskeletal system (1)
- muskuloskelettalen Bildgebung (1)
- myocardial blood flow (1)
- myokardiale Perfusion (1)
- neoadjuvant therapies (1)
- neonatal (1)
- nephrocalcinosis (1)
- neural networks (1)
- neurofilament light chain (1)
- neurology (1)
- neuronavigation (1)
- neuroradiology (1)
- neurosurgery (1)
- nipple discharge (1)
- nnU-net (1)
- non-small-cell lung (1)
- novel human cadaveric perfusion model (1)
- obesity (1)
- ocular manifestations (1)
- oedema (1)
- ollimator (1)
- oncology (1)
- ophthalmic artery (1)
- optic nerve (1)
- orbit (1)
- organ filters (1)
- organoid (1)
- orthopedic surgery (1)
- osteoarthritis (1)
- osteomalacia (1)
- osteoporosis (1)
- outcome prediction (1)
- paediatrics (1)
- pain (1)
- palliative care (1)
- parallel imaging (1)
- parathyroid carcinoma (1)
- patency rate (1)
- pathology (1)
- pediatric (1)
- pediatrics (1)
- pedicle screws (1)
- pelvic trauma (1)
- pembrolizumab (1)
- penile thrombosis (1)
- percutaneous biliary drainage (1)
- perfusion imaging (1)
- perfusion map (1)
- peripheral nervous system (1)
- peripheral vascular tree (1)
- perkutan (1)
- perkutane Rotationsthrombektomie (1)
- pharynx (1)
- phase-contrast MRI (1)
- phosphor (1)
- photo app (1)
- photon-counting (1)
- photon-counting CT (1)
- photon-counting computed tomography (CT) (1)
- photon-counting-detector CT (1)
- phytic acid (1)
- pig (1)
- plasmocytoma (1)
- polymyalgia rheumatica (1)
- polymyalgia-rheomatica (1)
- positive nodal status (1)
- post-neoadjuvant therapies (1)
- post-reconstruction filtering (1)
- pre-bolus technique (1)
- prebolus (1)
- prebolus technique (1)
- preoperative localization (1)
- prestyloid recess (1)
- preterm infants (1)
- priapism (1)
- primitive neuroectodermal tumor (1)
- primitiver neuroektodermaler Tumor (1)
- probabilistic (1)
- prognosis (1)
- prognostic marker on MRI (1)
- prognostische Marker (1)
- progression (1)
- proton-MR-spectroscopy (1)
- pränatal (1)
- pterionaler Zugang (1)
- pubic symphysis (1)
- pulmonary arteries (1)
- pädiatrischen Tumoren (1)
- pädiatrisches Polytrauma (1)
- quality (1)
- quality of life (1)
- radial (1)
- radiation dosage (1)
- radiation dose (1)
- radiation dose reduction (1)
- radiation myelitis (1)
- radiation protection (1)
- radical cystectomy (1)
- radiogenomics (1)
- radiologische Diagnostik im Schockraum (1)
- rare bone disease (1)
- read-outs (1)
- real-time (1)
- real-time imaging (1)
- refractory (1)
- regression analysis (1)
- relaxation (physics) (1)
- relaxation time (1)
- renal arteries (1)
- renal system (1)
- repeat surgery (1)
- repeated surgery (1)
- reproducibility (1)
- reproducibility of results (1)
- research infrastructure (1)
- resolution (1)
- resuscitation time (1)
- retroperitoneal tumor (1)
- rickets (1)
- rotational percutaneous mechanical thrombectomy (1)
- rotator cuff lesion (1)
- sacral nerve stimulation (1)
- sacral neuromodulation (1)
- salvage radiotherapy (1)
- sauropod dinosaurs (1)
- scanner (1)
- scannernoise (1)
- seahorse (1)
- segmentation (1)
- self‐gated (1)
- semantic segmentation (1)
- sensitivity (1)
- sequence imaging protocol (1)
- shimming (1)
- signal filtering (1)
- signal to noise ratio (1)
- singlevoxel (1)
- skeletal (1)
- small animal SPECT (1)
- small bowel MRI (1)
- small pixel effect (1)
- small-animal imaging (1)
- small-cell lung (1)
- smoking (1)
- smoldering myeloma (1)
- sodium (1)
- specifity (1)
- spectral CT (1)
- spectral imaging (1)
- spectroscopic sequences (1)
- spin labeling (1)
- spinal (1)
- spine (1)
- spine trauma (1)
- spiral trajectory (1)
- spleen (1)
- squamous tumors (1)
- staging (1)
- standardized reporting system (1)
- statistical data (1)
- stem cell transplantation (1)
- stenosis (1)
- stent (1)
- stent retriever (1)
- stents (1)
- stress (1)
- subarachnoid hemorrhage (1)
- subscapularis tear (1)
- superparamagnetic iron oxide particles (1)
- supraspinatus (1)
- supratentorial (1)
- supratentoriell (1)
- surgery (1)
- surgical repair (1)
- surgical trauma room (1)
- surgical treatment (1)
- sympathetic stimulation (CPT) (1)
- synovitis (1)
- systematic review (1)
- systemic vasculitides (1)
- tagging (1)
- temperature dependency (1)
- tetraparesis (1)
- thermal variation (1)
- thorax (1)
- three-dimensional imaging (1)
- totally implantable venous access port (1)
- tract embolization (1)
- transarterial chemoembolization (1)
- transarterial chemoembolization (TACE) (1)
- transarterielle Chemomebolisation (TACE) (1)
- transcranial dopplersonography (1)
- transfer learning (1)
- trauma centre (1)
- trauma management (1)
- traumatisch (1)
- traveling wave magnetic particle imaging (1)
- triangular fibrocartilage (1)
- triangular fibrocartilage complex (1)
- triglycerides (1)
- tube current modulation (1)
- tumor burden (1)
- ultrahigh field (1)
- ultrahigh resolution (1)
- ultrahigh-field (1)
- ultrahigh-field MRI (1)
- undersampling (1)
- vacuum-assisted biopsy (1)
- variational network (1)
- vascular (1)
- vascular access (1)
- vascular reconstruction (1)
- vasculature (1)
- vasculitis (1)
- vertebral pedicles (1)
- vertebral pneumaticity (1)
- virtual non-contrast (1)
- virtual noncalcium imaging (1)
- vitality of heart muscle (1)
- voiding cystourethrography (1)
- voiding urosonography (1)
- volume determination (1)
- wall shear stress (1)
- wave‐CAIPI (1)
- whole-body MRI (1)
- whole-body imaging (1)
- workflow (1)
- x-ray computed (1)
- zoledronic acid (1)
- Ödem (1)
- β-Hydroxybutyrate (1)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (243) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
The introduction of new therapeutic agents has revolutionized the treatment of metastatic melanoma. The approval of adjuvant anti‐programmed death‐1 monotherapy with nivolumab or pembrolizumab, and dabrafenib plus trametinib has recently set a new landmark in the treatment of stage III melanoma. Now, clinical trials have shown that immune checkpoint blockade can be performed in a neoadjuvant setting, an approach established as a standard therapeutic approach for other tumour entities such as breast cancer. Recent studies suggest that a pathological response achieved by neoadjuvant immunotherapy is associated with long‐term tumour control and that short neoadjuvant application of checkpoint inhibitors may be superior to adjuvant therapy. Most recently, neoadjuvant ipilimumab plus nivolumab in stage III melanoma was reported. With two courses of dose‐optimized ipilimumab (1 mg kg−1) combined with nivolumab (3 mg kg−1), pathological responses were observed in 77% of patients, while only 20% of patients experienced grade 3 or 4 adverse events. However, the neoadjuvant trials employing combined immune checkpoint blockade conducted so far have excluded patients with in transit metastases, a common finding in stage III melanoma. Here we report four patients with in transit metastases or an advanced primary tumour who have been treated with neoadjuvant ipilimumab plus nivolumab according to the OpACIN‐neo trial scheme (arm B). All patients achieved radiological disease control and a pathological response. None of the patients has relapsed so far.
Zur Abklärung malignitätsverdächtiger Befunde in der Brust benötigt man eine effektive minimal-invasive Methode. Diese retrospektive Studie evaluiert die Wertigkeit der Vakuumstanzbiopsie mit manueller Führung. Es zeigt sich, dass hier eine unkomplizierte und ausreichende Gewinnung von Gewebe und somit eine zuverlässige Einschätzung von mammographischen Auffälligkeiten möglich ist.
Background
Hypophosphatasia (HPP) is a rare, inherited metabolic disorder caused by loss-of-function mutations in the ALPL gene that encodes the tissue-nonspecific alkaline phosphatase TNAP (ORPHA 436). Its clinical presentation is highly heterogeneous with a remarkably wide-ranging severity. HPP affects patients of all ages. In children HPP-related musculoskeletal symptoms may mimic rheumatologic conditions and diagnosis is often difficult and delayed. To improve the understanding of HPP in children and in order to shorten the diagnostic time span in the future we studied the natural history of the disease in our large cohort of pediatric patients. This single centre retrospective chart review included longitudinal data from 50 patients with HPP diagnosed and followed at the University Children's Hospital Wuerzburg, Germany over the last 25 years.
Results
The cohort comprises 4 (8%) perinatal, 17 (34%) infantile and 29 (58%) childhood onset HPP patients. Two patients were deceased at the time of data collection. Diagnosis was based on available characteristic clinical symptoms (in 88%), low alkaline phosphatase (AP) activity (in 96%), accumulating substrates of AP (in 58%) and X-ray findings (in 48%). Genetic analysis was performed in 48 patients (31 compound heterozygous, 15 heterozygous, 2 homozygous mutations per patient), allowing investigations on genotype-phenotype correlations. Based on anamnestic data, median age at first clinical symptoms was 3.5 months (min. 0, max. 107), while median time to diagnosis was 13 months (min. 0, max. 103). Common symptoms included: impairment of motor skills (78%), impairment of mineralization (72%), premature loss of teeth (64%), musculoskeletal pain and craniosynostosis (each 64%) and failure to thrive (62%). Up to now 20 patients started medical treatment with Asfotase alfa.
Conclusions
Reported findings support the clinical perception of HPP being a chronic multi-systemic disease with often delayed diagnosis. Our natural history information provides detailed insights into the prevalence of different symptoms, which can help to improve and shorten diagnostics and thereby lead to an optimised medical care, especially with promising therapeutic options such as enzyme-replacement-therapy with Asfotase alfa in mind.
In der vorliegenden Arbeit wurde eine Eignung des Bolus Tracking beim 4-Phasen Spiral CT insbesondere zur Ermittlung einer optimalen Frühphase des hepatobiliären Systems nachgewiesen. Die optimale Frühphase wurde definiert bei 20%-30% Leberenhancement im Vergleich zur portalvenösen Phase. 250 Untersuchungen des Abdomens wurden an einem Spiral CT mit identischem Tischvorschub und Schichtdicke durchgeführt, wobei 200 Patienten mit Bolus Tracking und 50 Patienten mit Standardverfahren untersucht wurden. Die Startverzögerung der Frühphase beim Standardverfahren betrug 25 Sekunden und bei allen 250 Untersuchungen wurde für die portalvenöse Phase ein Delay von 60 Sekunden nach Start der arteriellen Phase gewählt. Zu Beginn der Studie wurden 150 Untersuchungen mit Bolus Tracking untersucht, dabei wurden die Patienten randomisiert auf 6 verschiedene Protokolle mit Schwellenwerten von 50 HE, 75 HE und 100 HE bei Startverzögerungen von 5 und 10 Sekunden aufgeteilt. Es ergab sich ein signifikanter Vorteil für das Protokoll mit einem Schwellenwert von 75 HE und 10 Sekunden Startverzögerung. Weitere 50 Untersuchungen bei einem Schwellenwert von 75 HE und einer Startverzögerung von 10 Sekunden wurden mit 50 Patienten mit Standardverfahren verglichen. Hier zeigte sich kein signifikanter Unterschied Bolus Tracking versus Standardverfahren bei jedoch einem tendenziellen Vorteil des Bolus Tracking.
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.
Ziel der vorliegenden Arbeit war a)die Untersuchung eines Patientenkollektives vor und drei Monate sowie ein Jahr nach Aortenklappenersatz, d.h. von Patienten, bei denen eine globale Linksherzerkrankung vorliegt. Es sollte herausgefunden werden, ob sich aus dem Energiestatus vor der Operation auf deren Erfolg rückschließen läßt und man somit Empfehlungen für den Zeit-punkt des Klappenersatzes aus einer 31P - MRS ableiten kann. Damit sollte erstmals eine quantitative Beurteilung des Metabolismus bei Herzklappenvitien sowie eine Korrelation der so ermittelten Parameter mit dem klinischen Zustand der Patienten vor und nach der Operation versucht werden. Es wurden 21 Patienten mit Aortenklappenvitien untersucht, für 14 davon lagen auch die Werte der ersten Kontrolle nach einem Vierteljahr und für 5 die Werte nach einem Jahr vor. Aortenklappenvitien führen zu einer globalen Herzerkrankung (hier überwiegend linksventrikuläre Hypertro-phie bei Klappenstenose). Dies vereinfacht die spektroskopische Unter-suchung. Es wurde eine quantitative Untersuchung des Energiestoff-wechsels des Herzens dieser Patienten durchgeführt. Dabei ergaben sich Hinweise darauf, daß die Patienten um so mehr von der Operation profi-tieren, je schlechter ihre präoperativen Werte waren. Es konnte jedoch kein Parameter als Kriterium für den besten Operationszeitpunkt etabliert werden. Hierzu ist die Beurteilung der Nachkontrollen sowie generell ei-nes größeren Patientenkollektives abzuwarten. b) Das zweite Patientenkollektiv bildeten Patienten, die einen Herzinfarkt erlitten hatten, d.h. mit einer regionalen Herzschädigung. Sie wurden vor und ein halbes Jahr nach Therapie durch PTCA oder Bypass-Operation untersucht. Ziel war die Beurteilung der Untersuchung auf ihre Zuverlässigkeit bezüglich der Unterscheidung von vitalem und avi-talem Herzmuskel im Infarktbereich. Diese ist wichtig für die Entschei-dung, ob die Patienten von einer Operation profitieren können oder nicht. In dieser Studie wurden 50 Patienten untersucht, absolut eine geringe Anzahl, verglichen mit den Größen der bislang publizierten Studien je-doch eine sehr große Studie. Der Vergleich zwischen infarzierten und nichtinfarzierten Arealen mittels MRS sowie die quantitative Beurteilung metabolischer Schäden bei einem Infarkt wurde hier erstmalig durchge-führt. Dabei zeigte sich eine signifikante Unterscheidung der Absolutwerte von Patienten und Probanden. Ein Kriterium für die Unterscheidung zwi-schem avitalem und hibernating oder stunned myocardium konnte hier noch nicht gefunden werden, offensichtlich reicht hierfür das einfache Verhältnis PCr/g-ATP nicht aus. Eventuell kann eine Kombination von Pa-rametern gefunden werden. Im Vergleich der eigenen Ergebnisse mit de-nen des Goldstandards, d.h. den Dobutamin-Streß-MRI Untersuchungen wies die Spektroskopie eine Sensitivität von 47,1% gegenüber dem Gold-standard auf. Dies liegt unter anderem daran, daß bei der MRI-Untersuchung einzelne Segmente beurteilt werden konnten, während die Beurteilung einer regionalen Herzerkrankung aufgrund der geringen Ort-sauflösung der Spektroskopie noch Schwierigkeiten bereitet. Sollte es in Zukunft möglich sein, SLOOP-Spektren aus einzelnen Herzsegmenten zu erhalten, könnte sich dieser Wert verbessern. c) Die gemessenen 31P-Spektren wurden mit 3 verschiedenen Auswer-tungsprogrammen, LUISE, AMARES und SLOOP untersucht. Die so gewonnenen Ergebnisse sollten verglichen und die Verfahren hinsicht-lich Leistungsfähigkeit/Genauigkeit, Durchführbarkeit und Nutzen ver-glichen werden. Im Vergleich der drei Auswertungsverfahren stellte sich Folgendes her-aus: Kriterium LUISE AMARES SLOOP einfache Handha-bung/Erlernbarkeit ++ +++ + regionale Herzbeurtei-lung ++ ++ + Vergleichbarkeit der Ergebnisse + ++ +++ geringer Zeitaufwand ++ +++ + Abbildung 61: Vergleich der 3 Auswertungsverfahren Das während der Laufzeit dieser Arbeit entwickelte SLOOP-Verfahren brachte den Durchbruch zur Absolutquantifizierung. Damit wird eine Vergleichbarkeit der von zu verschiedenen Zeitpunkten, von verschiedenen Patienten und unter-schiedlichenn Arbeitsgruppen gewonnenen Daten ohne Korrekturfaktoren mög-lich. Die Güte der damit ermittelten Werte zeigt sich unter anderem darin, daß nur mit den SLOOP-Werten signifikante Ergebnisse im Vergleich mit den MRI-Daten erzielt werden konnten. Dies liegt an der Tatsache, daß bei den anderen Verfahren eine zu große Streuung der Werte auftritt. Im Vergleich der drei Auswertungsverfahren liefert aber derzeit AMARES am schnellsten und einfachsten verwertbare Daten.
Background:
Contrast-enhanced cardiovascular magnetic resonance angiography (CE-CMRA) is the established imaging modality for patients with Marfan syndrome requiring life-long annual aortic imaging before and after aortic root replacement. Contrast-free CMRA techniques avoiding side-effects of contrast media are highly desirable for serial imaging but have not been evaluated in the postoperative setup of Marfan patients. The purpose of this study was to assess the feasibility of non-contrast balanced steady-state free precession (bSSFP) magnetic resonance imaging for aortic monitoring of postoperative patients with Marfan syndrome.
Methods:
Sixty-four adult Marfan patients after aortic root replacement were prospectively included. Fourteen patients (22%) had a residual aortic dissection after surgical treatment of type A dissection. bSSFP imaging and CE-CMRA were performed at 1.5 Tesla. Two radiologists evaluated the images regarding image quality (1 = poor, 4 = excellent), artifacts (1 = severe, 4 = none) and aortic pathologies. Readers measured the aortic diameters at defined levels in both techniques. Statistics included observer agreement for image scoring and diameter measurements and ROC analyses for comparison of the diagnostic performance of bSSFP and CE-CMRA.
Results:
Both readers observed no significant differences in image quality between bSSFP and CE-CMRA and found a median image quality score of 4 for both techniques (all p > .05). No significant differences were found regarding the frequency of image artifacts in both sequences (all p > .05). Sensitivity and specificity for detection of aortic dissections was 100% for both readers and techniques. Compared to bSSFP imaging, CE-CMRA resulted in higher diameters (mean bias, 0.9 mm; p < .05). The inter-observer biases of diameter measurements were not significantly different (all p > .05), except for the distal graft anastomosis (p = .001). Using both techniques, the readers correctly identified a graft suture dehiscence with aneurysm formation requiring surgery.
Conclusion:
Unenhanced bSSFP CMR imaging allows for riskless aortic monitoring with high diagnostic accuracy in Marfan patients after aortic root surgery.
In der vorliegenden Arbeit sollte untersucht werden, welcher individuelle Röhrenstrom für unterschiedliche anatomische Regionen (Schädel, Hals, Thorax und Abdomen) nötig ist um diagnostisch aussagekräftige CT-Aufnahmen zu erzeugen. In diese prospektive Studie wurden 262 erwachsene Patienten aufgenommen. Ausgehend von seit Jahren bewährten Standardparametern wurde für jede anatomische Region anhand eines Iterationsschemas der minimal notwendige Röhrenstrom durch mehrmalige Wiederholung des Referenzscans ermittelt und mit diesem Wert die Untersuchung durchgeführt. Drei voneinander unabhängige Radiologen beurteilten die Bildqualität vor und nach Röhrenstromanpassung ohne Kenntnis der Expositionsparameter. Für Untersuchungen des Schädels (n=50) ergab sich ein Einsparungspotentials von 13 %, bei Thoraxuntersuchungen (n=67) von 57 % und bei Untersuchungen des Abdomens (n=119) eine maximale Einsparung von 45 % der Standarddosis. Dabei lag die Standarddosis für Schädel- (CTDIW= 41,7 mGy), Thorax- (CTDIW= 9,7 mGy) und Abdomenuntersuchungen (CTDIW = 11,7 mGy) bereits im untersten Quartil der deutschen Expositionspraxis. Für Abdomenuntersuchungen fand sich eine lineare Beziehung zwischen dem erforderlichen Röhrenstrom und dem in der a.p.-Richtung im Oberbauch gemessenen Körperdurchmesser. Der erforderliche Röhrenstrom variierte von 110 bis 325 mA (CTDIW=6,4-17,6 mGy) und die Körperdurchmesser von 16-35 cm. So ergibt sich, daß schlanke Patienten mit einem Durchmesser unter 27 cm bei den üblichen Expositionsparametern unnötig hohen Dosen ausgesetzt werden. Für diese Patienten kann man den notwendigen Röhrenstrom abschätzen, indem man den Körperdurchmesser mit ¾ multipliziert. Durch die individuelle Anpassung des Röhrenstroms an den Körperdurchmesser wird die Strahlenexposition bei Abdomen-CT-Untersuchungen um bis zu 45 % gesenkt ohne Beeinträchtigung der diagnostischen Aussagekraft. Für CT-Untersuchungen des Thorax ist das Einsparungspotential unabhängig vom Körperdurchmesser, im Mittel reicht ein Röhrenstrom von 73 mA (CTDIW= 4,2 mGy) aus. Bei CT-Untersuchungen des Gehirnschädels ergab sich das geringste Einsparpotential mit einer notwendigen Dosis CTDIW = 36,2 mGy bei durchschnittlich 174 mA. Der Studienarm Hals wurde vorzeitig wegen Zunahme von Aufhärtungsartefakten durch den Unterkiefer bzw. die Schulter abgebrochen.
In der Diagnostik der KHK und für die richtige Therapieentscheidung ist die myokardiale Perfusion von besonderem Interesse. Die verminderte Mikrozirkulation als funktionelle Folge einer Stenose korreliert mit den Beschwerden und der Prognose für einen Patienten mit KHK besser als die Morphologie der Stenose selbst. In der koronaren Angiographie wird die vaskuläre Situation der Herzkranzgefäße beurteilt und in Stenosegrade eingeteilt. Die Stenosen bedingen aber häufig nicht die entsprechende myokardiale Minderdurchblutung, so dass oft zusätzliche Untersuchungen der Ischämiediagnostik wie beispielsweise die Myokardszintigraphie oder die Stressechokardiographie erforderlich sind. Die MR-Perfusionsmessung kann bereits zur KHK-Primärdiagnostik eingesetzt werden. Die Bestimmung der hämodynamischen Relevanz einer Stenose und der Nachweis einer mikrovaskulärern Obstruktion nach Infarkt und die Therapiekontrolle nach Revaskularisierung ist möglich. Hier könnte in Zukunft die quantitative MR Perfusionsmessung den Vergleich von MR Perfusionsmessungen mit anderen Modalitäten erleichtern. Die Magnetresonanztomographie für die Bestimmung der Herzperfusion wird zunehmend in der Klinik angewendet. Die Auswertung erfolgt in der Regel nicht quantitativ, sondern rein visuell. Die quantitative Bestimmung der myokardialen Perfusion mittels MRT ist Gegenstand der aktuellen Forschung. In der vorliegenden Arbeit wurde die von Köstler beschriebene Präbolus Technik eingesetzt, die quantitative Aussagen über die myokardiale Perfusion mit einer geringen Variabilität ermöglicht. Diese Untersuchungstechnik wurde bei herzgesunden Probanden getestet. Für die quantitativen Perfusionsuntersuchungen wurde das Myokard in allen Bildern manuell segmentiert (d.h. markiert). Anschließend wurden aus den segmentierten Bildern Konzentrations-Zeit-Kurven im Myokard und im linken Ventrikel bestimmt. Aus diesen Kurven wurden durch Entfaltung mit der arteriellen Inputfunktion zu einer Modellfunktion quantitative Werte für die Perfusion gemessen. Das Ziel dieser Studie war die Untersuchung verschiedener Aspekte der Auswerteverfahren in der Herzperfusionsdiagnostik, um die Auswertung optimieren zu können. Die Untersuchungen für die quantitative Bestimmung der Myokardperfusion erfolgten mittels Präbolus-Technik und einer Multislice SSFP-Sequenz. Zur Bestimmung einer optimierten Segmentation des Myokards bei der quantitativen Bestimmung der Herzperfusion in der MRT ist es möglich, die tatsächlichen Myokardgrenzen zu verwenden, wenn eine Kontaminationskorrektur eingesetzt wird. Dabei wird das Signal-zu-Rausch-Verhältnis verbessert und die Variabilität der Perfusionswerte vermindert. Die subendokardiale und subepikardiale Perfusion können bestimmt werden. Die Untersuchung der Perfusion der subendo- und subepikardialen Schicht des menschlichen Herzens zeigte bei den untersuchten gesunden Probanden eine höhere Perfusion der subendokardialen Anteile. Künftig könnten auch in der klinischen Routine subendo- und subepikardiale Schichten getrennt ausgewertet werden, um somit eine Differenzierung eines Perfusionsdefizites zu ermöglichen. Ziel ist es, auch kleine Durchblutungsstörungen oder eine Minderdurchblutung nur der inneren Schichten des Herzmuskels quantitativ nachzuweisen. Hierzu müssen die Ergebnisse dieser Studie mit Ergebnissen von Patienten verglichen werden. Werden die Werte von quantitativen Perfusionsauswertungen mit einer Fermi- oder Exponentialfunktion ausgewertet, zeigt sich ein linearer Zusammenhang der Ergebnisse, die ineinander umgerechnet werden können. Beide Modellfunktionen sind somit für die Auswertung der Herzperfusionsuntersuchung einsetzbar. Des Weiteren wurde gezeigt, dass es durch die Entfaltung der Konzentrations-Zeit-Kurven möglich ist, die myokardiale Perfusion bei gesunden Probanden korrekt zu messen, auch wenn nur die Bilder jedes n-ten Herzschlages berücksichtigt werden. Patientenstudien müssen zeigen, ob dies auch für minderperfundierte Areale zutrifft und ob diese eindeutig determiniert werden können. Die Interobservervariabilität liegt in der Größenordung der Streuung der Flusswerte bei gesunden Probanden. Die Beurteilbarkeit unterschiedlicher Regionen des Herzens hinsichtlich der Mikrozirkulation und der daraus abzuleitenden therapeutischen Konsequenzen sind das primäre Ziel. Mit der quantitativen MR-Herz-Perfusionsmessung soll ein validiertes diagnostisches Instrumentarium für die Bestimmung der Herzdurchblutung zur Verfügung gestellt werden. Diese Arbeit liefert einen Beitrag zur Optimierung der Auswertung der Herzperfusion und hilft damit den Stellenwert der MR-Herzperfusionsmessung zu verbessern. Die MRT könnte auf Grund der hohen räumlichen Auflösung und der Möglichkeit der Quantifizierung in Zukunft zum Goldstandard bei Herzperfusionsuntersuchungen werden
In der Nachsorge des Medulloblastoms wird standardmäßig auf die Bildgebung mittels Magnetresonanztomographie zurück gegriffen. Da die Erkrankung vor allem entlang der Liquorwege in Form einer kranialen oder spinalen Meningeose metastasiert, wurde anhand Daten der Therapieoptimierungsstudie "HIT 2000" verglichen, welche Lokalisation am häufigsten betroffen ist. Es zeigte sich, dass zu einem hohen Prozentanteil vor allem eine kombinierte Meningeose im Rezidiv oder Progress auftritt, gefolgt von einer kranialen Metastasierung. Dennoch gibt es eine Gruppe an Patienten, die eine isolierte spinale Meningeose entwickeln.
Acute ischemic cardiac injury predisposes one to cognitive impairment, dementia, and depression. Pathophysiologically, recent positron emission tomography data suggest astroglial activation after experimental myocardial infarction (MI). We analyzed peripheral surrogate markers of glial (and neuronal) damage serially within 12 months after the first ST-elevation MI (STEMI). Serum levels of glial fibrillary acidic protein (GFAP) and neurofilament light chain (NfL) were quantified using ultra-sensitive molecular immunoassays. Sufficient biomaterial was available from 45 STEMI patients (aged 28 to 78 years, median 56 years, 11% female). The median (quartiles) of GFAP was 63.8 (47.0, 89.9) pg/mL and of NfL 10.6 (7.2, 14.8) pg/mL at study entry 0–4 days after STEMI. GFAP after STEMI increased in the first 3 months, with a median change of +7.8 (0.4, 19.4) pg/mL (p = 0.007). It remained elevated without further relevant increases after 6 months (+11.7 (0.6, 23.5) pg/mL; p = 0.015), and 12 months (+10.3 (1.5, 22.7) pg/mL; p = 0.010) compared to the baseline. Larger relative infarction size was associated with a higher increase in GFAP (ρ = 0.41; p = 0.009). In contrast, NfL remained unaltered in the course of one year. Our findings support the idea of central nervous system involvement after MI, with GFAP as a potential peripheral biomarker of chronic glial damage as one pathophysiologic pathway.
Mapping the longitudinal relaxation time \(T_1\) has widespread applications in clinical MRI as it promises a quantitative comparison of tissue properties across subjects and scanners. Due to the long scan times of conventional methods, however, the use of quantitative MRI in clinical routine is still very limited. In this work, an acceleration of Inversion-Recovery Look-Locker (IR-LL) \(T_1\) mapping is presented. A model-based algorithm is used to iteratively enforce an exponential relaxation model to a highly undersampled radially acquired IR-LL dataset obtained after the application of a single global inversion pulse. Using the proposed technique, a \(T_1\) map of a single slice with 1.6mm in-plane resolution and 4mm slice thickness can be reconstructed from data acquired in only 6s. A time-consuming segmented IR experiment was used as gold standard for \(T_1\) mapping in this work. In the subsequent validation study, the model-based reconstruction of a single-inversion IR-LL dataset exhibited a \(T_1\) difference of less than 2.6% compared to the segmented IR-LL reference in a phantom consisting of vials with \(T_1\) values between 200ms and 3000ms. In vivo, the \(T_1\) difference was smaller than 5.5% in WM and GM of seven healthy volunteers. Additionally, the \(T_1\) values are comparable to standard literature values. Despite the high acceleration, all model-based reconstructions were of a visual quality comparable to fully sampled references. Finally, the reproducibility of the \(T_1\) mapping method was demonstrated in repeated acquisitions. In conclusion, the presented approach represents a promising way for fast and accurate \(T_1\) mapping using radial IR-LL acquisitions without the need of any segmentation.
In this work, a model-based acceleration of parameter mapping (MAP) for the determination of the tissue parameter T1 using magnetic resonance imaging (MRI) is introduced. The iterative reconstruction uses prior knowledge about the relaxation behavior of the longitudinal magnetization after a suitable magnetization preparation to generate a series of fully sampled k-spaces from a strongly undersampled acquisition. A Fourier transform results in a spatially resolved time course of the longitudinal relaxation process, or equivalently, a spatially resolved map of the longitudinal relaxation time T1.
In its fastest implementation, the MAP algorithm enables the reconstruction of a T1 map from a radial gradient echo dataset acquired within only a few seconds after magnetization preparation, while the acquisition time of conventional T1 mapping techniques typically lies in the range of a few minutes. After validation of the MAP algorithm for two different types of magnetization preparation (saturation recovery & inversion recovery), the developed algorithm was applied in different areas of preclinical and clinical MRI and possible advantages and disadvantages were evaluated.
Aims
To survey the perceived indications for magnetic resonance imaging of the small bowel (MRE) by experts, when MR enteroclysis (MREc) or MR enterography (MREg) may be chosen, and to determine how the approach to MRE is modified when general anaesthesia (GA) is required.
Materials and methods
Selected opinion leaders in MRE completed a questionnaire that included clinical indications (MREg or MREc), specifics regarding administration of enteral contrast, and how the technique is altered to accommodate GA.
Results
Fourteen responded. Only the diagnosis and follow-up of Crohn’s disease were considered by over 80 % as a valid MRE indication. The remaining indications ranged between 35.7 % for diagnosis of caeliac disease and unknown sources of gastrointestinal bleeding to 78.6 % for motility disorders. The majority chose MREg over MREc for all indications (from 100 % for follow-up of caeliac disease to 57.7 % for tumour diagnosis). Fifty per cent of responders had needed to consider MRE under GA. The most commonly recommended procedural change was MRI without enteral distention. Three had experience with intubation under GA (MREc modification).
Conclusion
Views were variable. Requests for MRE under GA are not uncommon. Presently most opinion leaders suggest standard abdominal MRI when GA is required.
Die 31P-MRS wird zur Diagnostik des Energiemetabolismus bei verschiedenen kardialen Erkrankungen eingesetzt. Die vorliegende Arbeit befasst sich mit einer Verbesserung und Vereinfachung der Quantifzierung kardialer Energiemetaboliten mittels der 31P-MRS. Durch Akquisitonsgewichtung kann eine genauere Beurteilung der Konzentrationen von PCr und ATP im gesunden Myokard durch Verbesserung der Effizienz und Sensitivität der 31P-MRS erreicht werden. Die Kontamination des MR-Signals durch die Brustwand wird mittels des CORRECT-SLIM-Algorithmus verringert. Eine Fallstudie am rechten Ventrikel zeigt die starke metabolische Aussagekraft der 31P-MRS vor, während und nach medikamentöser Therapie. Die 31P-MRS unter Verwendung räumlicher Sättigungspulse liefert einen unmittelbaren Einblick in den Energiemetabolismus des menschlichen Herzens mit einer deutlich kürzen Nachbearbeitungszeit. Durch diese Optimierungen ermöglicht die 31P-MRS des menschlichen Herzens eine exakte Beurteilung des Energiemetabolismus im gesunden wie erkrankten Myokard.
Background
Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI.
Methods
49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated.
Results
Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PD\(_{outflow}\)/PD\(_{inflow}\) increased by 65% (p < 0.001) and AUC\(_{outflow}\)/AUC\(_{inflow}\) increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05).
Conclusions
Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.
In der vorliegenden Arbeit wurde untersucht, ob die farbige DSA-Darstellungsweise besser als die monochromatische dazu geeignet ist, eine Entscheidung über eine mögliche Stentimplantation bei pAVK zu treffen.
Hierfür wurden DSA-Daten des Universitätsklinikums Würzburg im Zeitraum 04/2014 - 10/2015 retrospektiv ausgewertet. Drei Ärzte bewerteten die Bilder in zwei getrennten Durchgängen bezüglich ihrer Entscheidung zur Stentimplantation. Diese Entscheidungen wurden mit einem Konsensus aus 2 Ärzten verglichen. Anhand von ROC-Analysen konnte so die Treffsicherheit der Entscheidungen evaluiert werden.
In der Studie stellte sich die farbkodierte Darstellung im Vergleich zur monochromatischen Darstellung nicht als überlegen heraus.
Purpose:
The gradient system transfer function (GSTF) characterizes the frequency transfer behavior of a dynamic gradient system and can be used to correct non‐Cartesian k‐space trajectories. This study analyzes the impact of the gradient coil temperature of a 3T scanner on the GSTF.
Methods:
GSTF self‐ and B\(_0\)‐cross‐terms were acquired for a 3T Siemens scanner (Siemens Healthcare, Erlangen, Germany) using a phantom‐based measurement technique. The GSTF terms were measured for various temperature states up to 45°C. The gradient coil temperatures were measured continuously utilizing 12 temperature sensors which are integrated by the vendor. Different modeling approaches were applied and compared.
Results:
The self‐terms depend linearly on temperature, whereas the B0‐cross‐term does not. Effects induced by thermal variation are negligible for the phase response. The self‐terms are best represented by a linear model including the three gradient coil sensors that showed the maximum temperature dependence for the three axes. The use of time derivatives of the temperature did not lead to an improvement of the model. The B\(_0\)‐cross‐terms can be modeled by a convolution model which considers coil‐specific heat transportation.
Conclusion:
The temperature dependency of the GSTF was analyzed for a 3T Siemens scanner. The self‐ and B0‐cross‐terms can be modeled using a linear and convolution modeling approach based on the three main temperature sensor elements.
Der Morbus Fabry ist eine lysosomale Speicherkrankheit, die auf einem Mangel des Enzyms a-Galaktosidase A beruht. Die Krankheit wird X-chromosomal rezessiv vererbt und entsteht durch Mutation des a-Galaktosidase-Gens auf dem langen Arm des Chromosoms Xq22. Durch die erniedrigte bzw. fehlende Enzymaktivität kommt es zu einer übermäßigen Ablagerung von Glykosphingolipiden in sämtlichen Geweben des menschlichen Körpers, besonders betroffen sind Herz, Nieren, Gefäße und ZNS. Die Krankheit ist durch einen progredienten Verlauf und einer eingeschränkten Lebenserwartung gekennzeichnet. Insbesondere die kardialen Auswirkungen wie Herzrhythmusstörungen, Klappenvitien und linksventrikuläre Hypertrophie führen zur Herzinsuffizienz und fast immer zu einem meist frühzeitigen Tod durch Herzversagen. Seit einiger Zeit steht in der Enzymersatztherapie mit rekombinanter a-Galaktosidase A (Agalsidase) eine kausale Behandlung zur Verfügung. Unter der Therapie mit Agalsidase zeigen sich auch Verbesserungen der kardialen Parameter, insbesondere eine Reduktion der linksventrikulären Masse. Zur Kontrolle und zur Dokumentation der medikamentösen Wirkung an den verschiedenen Organen waren und sind klinische Studien und Untersuchungen der betroffenen Patienten notwendig. Zur Beurteilung der kardialen Funktion steht, neben den bekannten Routineverfahren wie der Echokardiographie und der MR-Bildgebung, mit der 31P-Magnetresonanz-Spektroskopie ein nicht invasives Verfahren zur Beurteilung des myokardialen Stoffwechsels zur Verfügung. Mit Hilfe von speziellen Auswerteprogrammen können die Absolutkonzentrationen von energiereichen Metaboliten, besonders von Phosphokreatin und Adenosintriphosphat, im Herzmuskel in vivo bestimmt werden. Ziel der vorliegenden Arbeit war zunächst einmal die Messung der Konzentrationen der energiereichen Metabolite im Myokard von Patienten mit Morbus Fabry und der Vergleich der Daten mit denen von gesunden Probanden. Des weiteren wurde die Patientengruppe unter Therapie mit Agalsidase b einer frühen und einer späten Kontrolluntersuchung mittels MR-Spektroskopie unterzogen, um Veränderungen im kardialen Metabolismus darzustellen. Die spektroskopischen Daten gaben Aufschluss über Ausmaß der Beeinträchtigung des myokardialen Stoffwechsels aufgrund der Gb3-Ablagerungen und ergänzten die klinischen und bildmorphologischen Untersuchungen. Hierbei konnte eine tendenzieller Anstieg der PCr- und ATP-Konzentrationen unter ERT im Myokard nachgewiesen werden, gleichfalls zeigten sich in dem untersuchten Kollektiv eine Abnahme der linksventrikulären Masse und eine erhöhte Ejektionsfraktion. Ebenso konnte dargelegt werden, dass wie auch bei anderen Herzerkrankungen, wie zum Beispiel der dilatativen Kardiomyopathie oder der koronaren Herzkrankheit, bei einer Stoffwechselerkrankung wie der Fabry-Krankheit deutlich verringerte Konzentrationen energiereicher Phosphate in den Herzmuskelzellen vorliegen.