Refine
Has Fulltext
- yes (4)
Is part of the Bibliography
- yes (4)
Document Type
- Doctoral Thesis (4)
Keywords
- Blutspiegel (4) (remove)
Eine klassische HIV-Primärtherapie setzt sich aus einer Kombination von zwei Nukleosidischen Reverse-Transkriptase-Inhibitoren (NRTI) mit Protease-Inhibitoren (PI) oder Nicht-Nukleosidischen Reverse-Transkriptase-Inhibitoren (NNRTI) zusammen. Vor allem aufgrund NRTI-assoziierter Nebenwirkungen durch mitochondriale Toxizität wird die Option eines Verzichts auf NRTI (NRTI-Sparing) untersucht. In der vorliegenden Langzeituntersuchung wurden drei therapienaive Patientenkollektive - (1) NRTI+PI [n=23], (2) NRTI+NNRTI [n=18] und (3) NNRTI+PI [n=19] - über 96 Wochen teilweise retrospektiv, teilweise prospektiv beobachtet. Die drei Kollektive wurden bezüglich Effektivität, Veränderungen von metabolischen und hämatologischen Laborparametern und kontinuierlichem Therapeutischen Drug Monitoring (TDM) anhand statistischer Auswertung verglichen. Dabei zeigten sich unter den NNRTI Efavirenz (EFV) und Nevirapin (NVP) geringere Plasmaspiegelschwankungen als unter PI. Im Vergleich der Therapiegruppen wurden für absolute und relative Plasmaspiegel keine signifikanten Unterschiede zwischen EFV, NVP und LPV (Lopinavir) beobachtet. Unabhängig des Krankheitsstadiums (CDC-Klassifikation) konnte in allen Gruppen eine maximale Suppression der Viruslast unter die Nachweisgrenze von <50 HIV-RNA-Kopien/ml und ein Anstieg der CD4-Zellzahlen beobachtet werden. Bezüglich virologischem und immunologischem Therapieerfolg gab es im Verlauf über 96 Wochen keinen signifikanten Unterschied zwischen den Therapiekollektiven. Im Vergleich der Laborparameter von Fett- und Leberstoffwechsel kam es zwischen den Gruppen zu signifikanten Unterschieden, wobei deutliche Anstiege und höchste Werte im NRTI-freien Kollektiv gemessen wurden. Für Hämoglobin wurde dies nicht beobachtet. NRTI-Sparing kann bei HIV-therapienaiven Patienten eine Option für eine effektive Langzeittherapie mit maximaler Virussuppression und ansteigender CD4-Zellzahl darstellen, scheint aber mit einem erhöhten Risiko für ansteigende Fettstoff- und Leberparameter assoziiert zu sein.
Für Kinder und Jugendliche stellt die Blutentnahme im Rahmen des Therapeutischen Drug Monitorings (TDM) aufgrund der Invasivität häufig eine große physische sowie psychische Belastung dar. Diese Stresssituation kann durch Speichelsammlung aufgrund des nicht invasiven Prozederes vermieden und zusätzlich der Material-, Personal- und Zeitaufwand im Vergleich zu einer Blutentnahme minimiert werden. Da die therapeutischen Referenzbereiche in der AGNP Konsensus-Leitlinie zum TDM von Psychopharmaka nur für Serum und Plasma validiert sind, sind vergleichende Untersuchungen von alternativen Matrizes mit Serum oder Plasma sowie eine klinische Validierung essenziell für die Implementierung in die klinische Praxis.
Die Zielsetzung dieser Arbeit war es daher, den Zusammenhang zwischen Speichel- und Serumkonzentrationen von Amphetamin und Guanfacin zu untersuchen, um zukünftig das Prozedere der Probenahme für TDM bei Kinder und Jugendliche unter ADHS-Pharmakotherapie durch ein nicht invasives Verfahren zu erleichtern. Zur quantitativen Bestimmung wurden zwei unterschiedliche Methoden aus der Literatur weiterentwickelt. So war es möglich, aus Speichel- und Serumproben Amphetamin mittels HPLC-FL Analytik sowie Guanfacin mittels LC-MS/MS Analytik zu quantifizieren. Die chromatographischen Methoden wurden in Anlehnung an die Richtlinien der Gesellschaft für toxikologische und forensische Chemie (GTFCh) erfolgreich validiert.
Zur Untersuchung des Zusammenhangs zwischen Speichel- und Serumkonzentrationen von Amphetamin und Guanfacin bei Kinder und Jugendlichen wurde eine klinische Studie in der Klinik und Poliklinik für Kinder- und Jugendpsychiatrie, Psychosomatik und Psychotherapie des Universitätsklinikum Würzburgs initiiert. Von 34 Probanden, die mit Lisdexamphetamin und/oder Guanfacin behandelt wurden, konnte jeweils eine korrespondierende Speichel- und Serumprobe gewonnen und quantifiziert werden. Für Amphetamin wurde belegt, dass der Speichel-pH-Wert einen erheblichen Einfluss auf die Wirkstoffverteilung, den Quotienten aus Speichel- und Serumkonzentration, hat (ρ = -0,712; P < 0,001). Dadurch konnte erstmalig unter Berücksichtigung des Speichel-pH-Wertes eine Berechnung der theoretischen Serumkonzentration aus der Speichelkonzentration durchgeführt werden. Es wurde zwar gezeigt, dass sich sowohl der Mittelwert der Differenzen durch die Berechnung theoretischen Serumkonzentration von -343 auf 12 ng/mL als auch die Anzahl der Messwert innerhalb des Akzeptanzintervalls von 20 % verbessern, jedoch war auch nach der Umrechnung die Differenz der Messwerte zu groß, sodass eine klinische Validierung für Amphetamin nicht möglich war. In dieser Studie wurde auch erstmals Guanfacin im Speichel nachgewiesen und quantifiziert, die Konzentrationen lagen zwischen 0,45 und 5,55 ng/mL und waren im Mittel dreifach niedriger als im Serum (2,36 ng/mL vs. 7,47 ng/mL; t (8) = 5,94; P < 0,001).
Die Speichelguanfacinkonzentration wies einen starken Zusammenhang mit der korrespondierenden Serumkonzentration auf (r = 0,758; P = 0,018). Obwohl ein nicht signifikanter Trend für den Einfluss des Speichel-pH-Wertes auf den Quotienten aus Speichel- und Serumkonzentration zu erkennen war, scheint dieser weniger stark ausgeprägt zu sein als bei Amphetamin und anderen basischen Arzneistoffen (r = -0,574; P = 0,106).
Mit der vorliegenden Arbeit konnte zum einen gezeigt werden, dass sich die Speichelbestimmung von Amphetamin nur zum qualitativen Nachweis für TDM eignet. Zum anderen konnte gezeigt werden, dass der Speichel-pH-Wert einen geringeren Einfluss auf die Speichelkonzentration von Guanfacin zu haben scheint, als es bei Amphetamin der Fall ist, und sich Guanfacin somit potenziell für TDM in Speichel eignet. Zukünftig könnten Speichelproben zur Kontrolle der Adhärenz sowohl von Amphetamin als auch von Guanfacin verwendet werden und die Probenahme für die Patienten vereinfachen.
The aim of the present work was to improve drug monitoring in patients with various diseases in the context of precision medicine. This was pursued through the development and validation of mass spectrometric methods for determining the drug concentrations of kinase inhibitors and their clinical application. Besides conventional approaches to determine plasma level concentrations, the focus was also on alternative sampling techniques using volumetric absorptive microsampling (VAMS).
A conventional LC-MS/MS method was developed for the determination of cabozantinib in human EDTA plasma and validated according to the guidelines of the European and United States drug authorities (EMA, FDA). The method met the required criteria for linearity, accuracy and precision, selectivity, sensitivity, and stability of the analyte. Validation was also performed for dilution integrity, matrix effect, recovery, and carry-over, with results also in accordance with the requirements. The importance of monitoring the exposure of cabozantinib was demonstrated by a clinical case report of a 34-year-old female patient with advanced adrenocortical carcinoma who also required hemodialysis due to chronic kidney failure. Expected cabozantinib plasma concentrations were simulated for this off-label use based on a population pharmacokinetic model. It was shown that the steady state trough levels were much lower than expected but could not be explained by hemodialysis. Considering the critical condition and potential drug-drug interaction with metyrapone, a substance the patient had taken among several others during the observation period, individual pharmacokinetics could consequently not be estimated without drug monitoring.
In addition, a VAMS method for simultaneous determination of ten kinase inhibitors from capillary blood was developed. This microsampling technique was mainly characterized by the collection of a defined volume of blood, which could be dried and subsequently analyzed. The guidelines for bioanalytical method validation of the EMA and FDA were also used for this evaluation. As the nature of dried blood samples differs from liquid matrices, further parameters were investigated. These include the investigation of the hematocrit effect, process efficiency, and various stability conditions, for example at increased storage temperatures. The validation showed that the developed method is suitable to analyze dried matrix samples accurate, precise, and selective for all analytes. Apart from the stability tests, all acceptance criteria were met. The decreased stability of two analytes was probably due to the reproducible but reduced recovery. In vitro studies provided results on the VAMS-to-plasma correlation to predict the analyte distribution between both matrices, at least in an exploratory manner. It revealed a heterogeneous picture of analytes with different VAMS-to-plasma distributions. Furthermore, the analysis of 24 patient samples indicated the applicability of at-home VAMS. Both should be confirmed later as part of the clinical validation.
The clinical investigation of the VAMS method pursued two objectives. On the one hand, the simultaneous collection of VAMS and serum samples should enable a conversion of the determined concentrations and, on the other hand, the feasibility of autonomous microsampling at home should be examined more closely. For the former, it could be shown that different conversion methods are suitable for converting VAMS concentrations into serum levels. The type of conversion was secondary for the prediction. However, the previously defined criteria could not be fulfilled for all five kinase inhibitors investigated. The framework conditions of the study led to increased variability, especially for analytes with short half-life. A low and varying hematocrit, caused by the underlying disease, also made prediction difficult for a specific patient collective. For the second objective, investigating the feasibility of VAMS, different aspects were considered. It could be shown that the majority of patients support home-based microsampling. The acceptance is likely to increase even further when microsampling is no longer part of a non-interventional study, but participation is accompanied by targeted monitoring and subsequent adjustment of the therapy. The fact that additional training increases understanding of the correct sampling procedure is also a source of confidence. Demonstrated stability during storage under real-life conditions underlines the practicality of this sampling technique.
Taken together, mass spectrometric methods for both plasma and VAMS could be developed and validated, and their clinical application could be successfully demonstrated. The availability of simple bioanalytical methods to determine kinase inhibitor exposure could improve access to prospective studies and thus facilitate the implementation of routine therapeutic drug monitoring.
Die oralen Antidiabetika Metformin und Sitagliptin werden überwiegend renal eliminiert, weshalb während der Therapie regelmäßig die Nierenfunktion abgeschätzt werden sollte. Dies geschieht mithilfe von Serumkreatinin-basierten Formeln, zum Beispiel der Gleichung nach Cockcroft-Gault.
Mit dem Ziel, zukünftig eine Möglichkeit für eine vereinfachte Kontrolle der Therapie mit Metformin und/oder Sitagliptin in Kapillarblutproben zu haben, wurde eine Methode zur Bestimmung der Konzentration von Kreatinin, Metformin und Sitagliptin aus Trockenblutproben (Dried Blood Spots, DBS) entwickelt. Als Träger zeigte Blotting Papier die besten Ergebnisse in Bezug auf die Handhabung und die Extraktionseffizienz. Aus einem einzelnen DBS gelang es, Metformin und Kreatinin mittels HPLC-UV und Sitagliptin mittels LC-MS/MS zu quantifizieren. Die flüssigchromatographischen Methoden wurden entsprechend der EMA- und FDA-Kriterien erfolgreich vollvalidiert. Die unteren Nachweisgrenzen (LLOQ) lagen bei 0,2 µg/mL für Metformin, 1,5 µg/mL für Kreatinin und 3 ng/mL für Sitagliptin.
Da Referenzbereiche für Arzneistoffkonzentrationen in der Regel für Serum/Plasma angegeben werden, wurde das Verteilungsverhalten der beiden Antidiabetika zwischen Plasma (cP) und Blutzellen (cBZ) mittels in-vitro Inkubationsversuchen ermittelt. Für Metformin betrug der Verteilungskoeffizient cP/cBZ 4,65 ± 0,73, für Sitagliptin 5,58 ± 0,98. Damit lagen beide Arzneistoffe mehr als 4-fach höher im Plasma als in den Blutzellen vor. Erythrozyten waren zuvor schon als tiefes Kompartiment für Metformin beschrieben worden, für Sitagliptin waren dieses die ersten Daten die zeigten, dass der Arzneistoff ebenfalls eine relevante Verteilung in die Blutzellen zeigt.
In Kooperation mit einer diabetologischen Schwerpunktpraxis wurde eine erste klinische Studie (Basisstudie) durchgeführt, die zum Ziel hatte, aus den DBS die Nierenfunktion abzuschätzen. In DBS von 70 Patienten wurden Metformin, und/oder Sitagliptin sowie Kreatinin quantifiziert. Mit Hilfe der von der Praxis übermittelten Serumkreatinin-konzentration konnte durch den Vergleich mit der Konzentration im Kapillarbut erstmalig ein Korrelationsfaktor bestimmt und verifiziert werden, um die Kapillarblut- in die Serumkonzentration des Kreatinins umzurechnen (F = cKapillarblut/cPlasma = 0,916 ± 0,088). So war es möglich, die Nierenfunktion über die Formel nach Cockcroft und Gault abzuschätzen.
In der Basisstudie fiel auf, dass die Konzentration des Sitagliptins im Blut der Patienten signifikant mit steigendem Hämatokrit korrelierte (Pearson R = 0,396; p < 0,05). Die nähere Untersuchung dieser Beobachtung mittels in-vitro Verteilungsversuchen zeigte eine sehr stark inter-individuell schwankende Verteilung des Sitagliptins zwischen Plasma und den Blutzellen und eine vom Hämatokrit (Hct) linear abhängige Verteilung. In Blut mit einem höheren Hct fand sich mehr Arzneistoff in den Blutzellen als in Blut mit niedrigerem Hct, was die höheren Gesamtkonzentrationen an Sitagliptin im DBS erklärte. Dialyseversuche in-vitro bestätigten, dass die Eliminationszeit mit steigendem Hämatokrit des Blutes anstieg. Damit konnte zum ersten Mal gezeigt werden, dass die Blutzellen ein tiefes Kompartiment für Sitagliptin darstellen.
Eine zweite klinische Studie (Feldstudie) wurde in Kooperation mit 14 öffentlichen Apotheken mit dem Ziel, repräsentative Konzentrationen für die Kapillarblutspiegel der beiden Medikamente unter Alltagsbedingungen zu ermitteln, durchgeführt. In DBS von 84 Patienten wurden wiederum Metformin, Sitagliptin und Kreatinin quantifiziert. Aus den Daten der beiden Studienpopulationen (n = 134) wurde für Metformin eine mittlere Konzentration von 2,22 ± 1,16 µg/mL und für Sitagliptin von 432,20 ± 268,79 ng/mL bestimmt. Mittels populationspharmakokinetischer Methoden konnten für beide Arzneistoffe zum ersten Mal Eliminationshalbwertszeiten (t1/2) aus Kapillarblut für Patienten mit einer Kreatininclearance größer und kleiner als 60 mL/min bestimmt werden. Erwartungsgemäß waren die t1/2 bei besserer Nierenfunktion kürzer, sowohl für Metformin (11,9 h versus 18,5 h) als auch für Sitagliptin (8,4 h versus 13,0 h). Für Sitagliptin waren dies erstmalige klinische Belege für eine ansteigende Eliminationszeit mit sinkender Nierenfunktion.
Die gewonnenen Daten boten zudem Gelegenheit, den literaturbekannten ungünstigen Effekt einer kombinierten Einnahme von Diuretika, NSAIDs, ACE-Inhibitoren und/oder Angiotensinrezeptorantagonisten („target drugs“) auf die Nierenfunktion („triple whammy“) zu betrachten. Tatsächlich korrelierten die Anzahl der eingenommenen „target drugs“ und auch die Dosis der Diuretika mit einer sinkenden Kreatininclearance der Patienten.
Mit vorliegender Arbeit wurden zum einen neue Erkenntnisse über die Pharmakokinetik des Sitagliptins gewonnen, zum anderen wurde die Grundlage geschaffen, um aus einem DBS die Blutspiegel von Metformin und Sitagliptin im Zusammenhang mit der Nierenfunktion zu betrachten. In Zukunft könnte diese Methode für ein Therapeutisches Drug Monitoring der beiden Arzneistoffe eingesetzt werden um dieses für Patienten aufgrund der minimalinvasiven Blutabnahme wesentlich angenehmer zu gestalten.