Refine
Has Fulltext
- yes (26)
Is part of the Bibliography
- yes (26)
Year of publication
Document Type
- Journal article (26)
Language
- English (26) (remove)
Keywords
- fracture (4)
- surgery (3)
- arthritis (2)
- classification (2)
- tendon (2)
- AS clavicle plate (1)
- Achilles (1)
- Barbed suture (1)
- Barbed suture material (1)
- Bunnell (1)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (26)
- Institut für Anatomie und Zellbiologie (2)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (2)
- Lehrstuhl für Orthopädie (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
- Urologische Klinik und Poliklinik (1)
EU-Project number / Contract (GA) number
- 309962 (1)
Background
To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible.
Methods
A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected.
Results
Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day.
Conclusion
Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.
Traumatic brain injury (TBI) is the leading cause of death and disability in polytrauma and is often accompanied by concomitant injuries. We conducted a retrospective matched-pair analysis of data from a 10-year period from the multicenter database TraumaRegister DGU\(^®\) to analyze the impact of a concomitant femoral fracture on the outcome of TBI patients. A total of 4508 patients with moderate to critical TBI were included and matched by severity of TBI, American Society of Anesthesiologists (ASA) risk classification, initial Glasgow Coma Scale (GCS), age, and sex. Patients who suffered combined TBI and femoral fracture showed increased mortality and worse outcome at the time of discharge, a higher chance of multi-organ failure, and a rate of neurosurgical intervention. Especially those with moderate TBI showed enhanced in-hospital mortality when presenting with a concomitant femoral fracture (p = 0.037). The choice of fracture treatment (damage control orthopedics vs. early total care) did not impact mortality. In summary, patients with combined TBI and femoral fracture have higher mortality, more in-hospital complications, an increased need for neurosurgical intervention, and inferior outcome compared to patients with TBI solely. More investigations are needed to decipher the pathophysiological consequences of a long-bone fracture on the outcome after TBI.
The calcaneal beak fracture is a rare avulsion fracture of the tuber calcanei characterized by a solid bony fragment at the Achilles tendon insertion. Treatment usually requires osteosynthesis. However, lack of biomechanical understanding of the ideal fixation technique persists. A beak fracture was simulated in synthetic bones and assigned to five different groups of fixation: A) 6.5-mm partial threaded cannulated screws, B) 4.0-mm partial threaded cannulated screws, C) 5.0-mm headless cannulated compression screws, D) 2.3-mm locking plate, and E) 2.8-mm locking plate. Different traction force levels were applied through an Achilles tendon surrogate in a material-testing machine on all stabilized synthetic bones. Outcome measures were peak-to-peak displacement, total displacement, plastic deformation, stiffness, visual-fracture-line displacement, and mode of implant failure. The 2.3- and 2.8-mm plating groups showed a high drop-out rate at 100 N tension force and failed under higher tension levels of 200 N. The fracture fixation using 4.0-mm partial threaded screws showed a significantly higher repair strength and was able to withhold cyclic loading up to 300 N. The lowest peak-to-peak displacement and the highest load-to-failure and stiffness were provided by fracture fixation using 6.5-mm partial threaded cannulated screws or 5.0-mm headless cannulated compression screws. As anticipated, large 6.5-mm screw diameters provide the best biomechanical fixation. Surprisingly, the 5.0-mm headless cannulated compression screws yield reliable stability despite the absent screw head and washer. When such large screws cannot be applied, 4.0-mm screws also allow reasonable fixation strength. Plate fixation should be implemented with precaution and in combination with a restrictive postoperative motion protocol. Finally, clinical cases about the surgical application and recovery are included.
Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Background
Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice.
Methods
Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers.
Results
In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676–0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525–0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771–0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692–0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912).
Conclusions
The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.
Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required.
The aim of this study was to compare two different techniques of performing one-level spondylodesis for thoracolumbar burst fractures using either an autologous iliac crest bone graft (ICBG) or a porous tantalum fusion implant (PTFI). In a prospective nonrandomized study, 44 patients (20 women, 24 men; average age 43.1 +/- 13.2 years) suffering from severe thoracolumbar burst fractures were treated with combined anterior-posterior stabilization. An ICBG was used in 21 cases, and a PTFI was used in the other 23 cases. A two-year clinical and radiographic follow-up was carried out. There were no statistically significant differences in age, sex, localization/classification of the fracture, or visual analog scale (VAS) before injury between the two groups. All 44 patients were followed up for an average period of 533 days (range 173-1567). The sagittal spinal profile was restored by an average of 11.1 degrees (ICBG) vs. 14.3 degrees (PTFI) (monosegmental Cobb angle). Loss of correction until the last follow-up tended to be higher in the patients treated with ICBG than in those treated with PTFI (mean: 2.8 degrees vs. 1.6 degrees). Furthermore, significantly better restoration of the sagittal profile was obtained with the PTFI than with the iliac bone graft at the long-term follow-up (mean: ICBG 7.8 degrees, PTFI 12.3 degrees; p < 0.005). Short-segment posterior instrumentation combined with anterior one-level spondylodesis using either an ICBG or a PTFI resulted in sufficient correction of posttraumatic segmental kyphosis. PTFI might be a good alternative for autologous bone grafting and prevent donor site morbidities.
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
When aiming at cell‐based therapies in osteoarthritis (OA), proinflammatory conditions mediated by cytokines such as IL‐1β need to be considered. In recent studies, the phytoalexin resveratrol (RSV) has exhibited potent anti‐inflammatory properties. However, long‐term effects on 3D cartilaginous constructs under inflammatory conditions with regard to tissue quality, especially extracellular matrix (ECM) composition, have remained unexplored. Therefore, we employed long‐term model cultures for cell‐based therapies in an in vitro OA environment and evaluated effects of RSV. Pellet constructs made from expanded porcine articular chondrocytes were cultured with either IL‐1β (1–10 ng/ml) or RSV (50 μM) alone, or a cotreatment with both agents. Treatments were applied for 14 days, either directly after pellet formation or after a preculture period of 7 days. Culture with IL‐1β (10 ng/ml) decreased pellet size and DNA amount and severely compromised glycosaminoglycan (GAG) and collagen content. Cotreatment with RSV distinctly counteracted the proinflammatory catabolism and led to partial rescue of the ECM composition in both culture systems, with especially strong effects on GAG. Marked MMP13 expression was detected in IL‐1β‐treated pellets, but none upon RSV cotreatment. Expression of collagen type I was increased upon IL‐1β treatment and still observed when adding RSV, whereas collagen type X, indicating hypertrophy, was detected exclusively in pellets treated with RSV alone. In conclusion, RSV can counteract IL‐1β‐mediated degradation and distinctly improve cartilaginous ECM deposition in 3D long‐term inflammatory cultures. Nevertheless, potential hypertrophic effects should be taken into account when considering RSV as cotreatment for articular cartilage repair techniques.
Background
The role of cement-augmented screw fixation for calcaneal fracture treatment remains unclear. Therefore, this study was performed to biomechanically analyze screw osteosynthesis by reinforcement with either a calcium phosphate (CP)-based or polymethylmethacrylate (PMMA)-based injectable bone cement.
Methods
A calcaneal fracture (Sanders type IIA) including a central cancellous bone defect was generated in 27 synthetic bones, and the specimens were assigned to 3 groups. The first group was fixed with four screws (3.5 mm and 6.5 mm), the second group with screws and CP-based cement (Graftys (R) QuickSet; Graftys, Aix-en-Provence, France), and the third group with screws and PMMA-based cement (Traumacem (TM) V+; DePuy Synthes, Warsaw, IN, USA). Biomechanical testing was conducted to analyze peak-to-peak displacement, total displacement, and stiffness in following a standardized protocol.
Results
The peak-to-peak displacement under a 200-N load was not significantly different among the groups; however, peak-to-peak displacement under a 600- and 1000-N load as well as total displacement exhibited better stability in PMMA-augmented screw osteosynthesis compared to screw fixation without augmentation. The stiffness of the construct was increased by both CP- and PMMA-based cements.
Conclusion
Addition of an injectable bone cement to screw osteosynthesis is able to increase fixation strength in a biomechanical calcaneal fracture model with synthetic bones. In such cases, PMMA-based cements are more effective than CP-based cements because of their inherently higher compressive strength. However, whether this high strength is required in the clinical setting for early weight-bearing remains controversial, and the non-degradable properties of PMMA might cause difficulties during subsequent interventions in younger patients.
Background: The soft tissue of the central pretibial area is difficult to reconstruct often requiring free tissue transfer. Especially medi- cally compromised patients are not ideal candidates for free tissue transfer and may benefit from expeditiously harvested local flaps with limited donor site morbidity. As muscle flaps are rare, pedi- cled flaps based on lateral perforators represent an alternative as the arc of rotation can often be limited to 90 °.
Material and Methods: A retrospective analysis of patient data was conducted to identify patients over the age of 60 years with comor- bidities that underwent pretibial soft tissue reconstruction with a single-pedicle perforator flap. Patient demographics, size and cause of the defect, flap dimension, arc of rotation and complications were recorded.
Results: Five patients with an average age of 71.4 years were in- cluded. The arc of rotation was 69 °, all flaps healed. There were two recurrences of osteomyelitis.
Conclusion: Lateral perforators originating from the anterior tib- ial artery or peroneal artery are adequate source vessels for single pedicled perforator flaps even in medically compromised patients. A perforator located proximal to the defect allows limiting the arcof rotation to less than 90 °, which increases the safety of the flap. Patients benefit from a simple procedure without a microvascular anastomosis and a donor site confined to one extremity
Background:
Although indocyanine-green fluorescence angiography (ICG-FA) has been established as a useful tool to assess perfusion in free tissue transfer, only few studies have applied this modality to pedicled perforator flaps. As both volume and reach of pedicled perforator flaps are limited and tip necrosis often equals complete flap failure, ICG-FA may help to detect hypoperfusion in pedicled flaps.
Methods:
In 5 patients, soft tissue reconstruction was achieved with pedicled perforator flaps. ICG-FA was utilized intraoperatively to visualize flap perfusion.
Results:
Three pedicled anterolateral thigh flap flaps and 2 propeller flaps were transferred. ICG-FA detected hypoperfusion in 2 flaps. No flap loss occurred; in 2 cases, prolonged wound healing was encountered.
Conclusions:
ICG-FA confirmed clinical findings and reliably detected tissue areas with hypoperfusion. A clear cut-off point between nonvital tissue and such that stabilized in the following clinical course could not be found. ICG-FA is a promising technology which could also be used in pedicled perforator flaps.
Background:
Pedicled perforator flaps have expanded reconstructive options in extremity reconstruction. Despite preoperative mapping, intraoperative findings may require microvascular tissue transfer when no adequate perforators can be found. The free peroneal artery perforator flap may serve as a reliable back-up plan in small defects.
Methods:
In 16 patients with small soft tissue defects on the upper and lower extremities, perforator-based propeller flaps were planned. The handheld Doppler device was used to localize potential perforators for a propeller flap in close proximity to the defect. Perforators of the proximal peroneal artery were also marked to allow conversion to microvascular tissue transfer.
Results:
In 6 cases, no adequate perforators were found intraoperatively. In 4 patients, the peroneal artery perforator flap was harvested and transferred. The pedicle length did not exceed 4 cm. No flap loss occurred.
Conclusions:
When no adequate perforator capable of nourishing a propeller flap can be found intraoperatively, the free peroneal artery flap is a good option to reconstruct small soft tissue defects in the distal extremities. The short vascular pedicle is less ideal in cases with a large zone of injury requiring a more distant site of anastomosis or when recipient vessels are located in deeper tissue planes.
We report on a 14 months old toddler who sustained a traumatic hemipelvectomy by being crushed between a car and a stone wall. After stabilization in the resuscitation room he was treated operatively by laparotomy, osteosynthesis of the pelvic ring, reconstruction of the both external iliac vessels and the urethra and reposition of the testicles. After 66 days he was discharged into rehabilitation. Implants were removed after eight months. 20 months after the injury, the leg was plegic, initial radiological signs of femoral head necrosis showed up but the infant was able to walk with an orthesis and a walker.
Up to our knowledge, this is the youngest patient described in the literature with a survived traumatic hemipelvectomy and salvaged limb.
Background
Postoperative pulmonary complications (PPCs) increase morbidity and mortality of surgical patients, duration of hospital stay and costs. Postoperative atelectasis of dorsal lung regions as a common PPC has been described before, but its clinical relevance is insufficiently examined. Pulmonary electrical impedance tomography (EIT) enables the bedside visualization of regional ventilation in real-time within a transversal section of the lung. Dorsal atelectasis or effusions might cause a ventral redistribution of ventilation. We hypothesized the existence of ventral redistribution in spontaneously breathing patients during their recovery from abdominal and peripheral surgery and that vital capacity is reduced if regional ventilation shifts to ventral lung regions.
Methods
This prospective observational study included 69 adult patients undergoing elective surgery with an expected intermediate or high risk for PPCs. Patients undergoing abdominal and peripheral surgery were recruited to obtain groups of equal size. Patients received general anesthesia with and without additional regional anesthesia. On the preoperative, the first and the third postoperative day, EIT was performed at rest and during spirometry (forced breathing). The center of ventilation in dorso-ventral direction (COVy) was calculated.
Results
Both groups received intraoperative low tidal volume ventilation. Postoperative ventral redistribution of ventilation (forced breathing COVy; preoperative: 16.5 (16.0–17.3); first day: 17.8 (16.9–18.2), p < 0.004; third day: 17.4 (16.2–18.2), p = 0.020) and decreased forced vital capacity in percentage of predicted values (FVC%predicted) (median: 93, 58, 64%, respectively) persisted after abdominal surgery. In addition, dorsal to ventral shift was associated with a decrease of the FVC%predicted on the third postoperative day (r = − 0.66; p < 0.001). A redistribution of pulmonary ventilation was not observed after peripheral surgery. FVC%predicted was only decreased on the first postoperative day (median FVC%predicted on the preoperative, first and third day: 85, 81 and 88%, respectively). In ten patients occurred pulmonary complications after abdominal surgery also in two patients after peripheral surgery.
Conclusions
After abdominal surgery ventral redistribution of ventilation persisted up to the third postoperative day and was associated with decreased vital capacity. The peripheral surgery group showed only minor changes in vital capacity, suggesting a role of the location of surgery for postoperative redistribution of pulmonary ventilation.
Background:
Reverse oblique distal radio-ulnar joint (DRUJ) configuration is assumed to show inferior postoperative results in ulnar-shortening osteotomy due to osteoarthritis, as the joint force pressure in the DRUJ may be increased. An evaluation and comparison of the postoperative functional results with regard to clinical and radiographic signs of arthritis among different DRUJ configurations was carried out retrospectively.
Methods:
Sixty-two patients after ulnar shortening osteotomy were included. The minimum follow-up was 5 years. Preoperative x-rays were assessed for the DRUJ configuration according to the Tolat classification, whereas postoperative radiographs were evaluated with regard to signs of osteoarthritis using the Kallgren-Lawrence-Score. Functional results were evaluated using the disabilities of the arm, shoulder and hand (DASH) and Mayo Wrist Score and measuring range of motion and grip strength.
Results:
Significantly better functional results were found in patients with parallel configuration of the DRUJ (Tolat type 1 configuration) with regard to DASH score, grip strength, and supination compared with nonparallel configurations. In the Tolat type 1, configurated DRUJ mean DASH score was 9 compared with 18 in the Tolat type 2 and 3 groups. Apart from supination, no differences were observed in range of motion among groups.
Conclusion:
Although long-term postoperative range of motion failed to display statistically significant differences between DRUJ configurations except for supination, better results regarding grip strength and DASH scores were seen in a parallel-aligned DRUJ configuration. Although onset of osteoarthritis does not seem to become apparent within the observation period, nonparallel aligned configuration predisposes to inferior results.
Background
Tibial head depression fractures demand a high level of fracture stabilization to prevent a secondary loss of reduction after surgery. Elderly individuals are at an increased risk of developing these fractures, and biomechanical investigations of the fractures are rare. Therefore, the aim of this study was to systematically analyze different types of osteosyntheses in combination with two commonly used bone substitutes.
Methods
Lateral tibial head depression fractures were created in synthetic bones. After reduction, the fractures were stabilized with eight different treatment options of osteosynthesis alone or in combination with a bone substitute. Two screws, 4 screws and a lateral buttress plate were investigated. As a bone substitute, two common clinically used calcium phosphate cements, Norian® Drillable and ChronOS™ Inject, were applied. Displacement of the articular fracture fragment (mm) during cyclic loading, stiffness (N/mm) and maximum load (N) in Load-to-Failure tests were measured.
Results
The three different osteosyntheses (Group 1: 2 screws, group 2: 4 screws, group 3: plate) alone revealed a significantly higher displacement compared to the control group (Group 7: ChronOS™ Inject only) (Group 1, 7 [p < 0.01]; group 2, 7 [p = 0.04]; group 3, 7 [p < 0.01]). However, the osteosyntheses in combination with bone substitute exhibited no differences in displacement compared to the control group. The buttress plate demonstrated a higher normalized maximum load than the 2 and 4 screw osteosynthesis. Comparing the two different bone substitutes to each other, ChronOS™ inject had a significantly higher stiffness and lower displacement than Norian® Drillable.
Conclusions
The highest biomechanical stability under maximal loading was provided by a buttress plate osteosynthesis. A bone substitute, such as the biomechanically favorable ChronOS™ Inject, is essential to reduce the displacement under lower loading.
Background:
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps.
Methods:
In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap.
Results:
The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss.
Conclusions:
The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Background:
Bone-ligament-bone grafts for reconstruction of the scapholunate ligament are a valuable tool to prevent disease progression to carpal collapse. Locally available grafts do not require an additional donor site. The first extensor compartment was evaluated biomechanically regarding its possible use as an autograft.
Methods:
Twelve native fresh-frozen, human cadaver specimens were tested by applying axial tension in a Zwick Roell machine. Load to failure, transplant elongation, and bony avulsion were recorded. The load to failure was quantitated in newtons (N) and the displacement in length (millimeters). Parameters were set at distinct points as start of tension, 1 mm stretch and 1.5 mm dissociation, failure and complete tear, and were evaluated under magnified visual control. Although actual failure occurred at higher tension, functional failure was defined at a stretch of 1.5 mm.
Results:
Mean load at 1 mm elongation was 44.1 ± 28 N and at 1.5 mm elongation 57.5 ± 42 N. Failure occurred at 111 ± 83.1 N. No avulsion of the bony insertion was observed. Half the transplants failed in the central part of the ligament, while the rest failed near the insertion but not at the insertion itself. Analysis of tension strength displayed a wide range from 3.8 to 83.7 N/mm at a mean of 33.4 ± 28.4 N/mm.
Conclusions:
The biomechanical tensile properties of the first dorsal extensor compartment are similar to those of the dorsal part of the scapholunate ligament. A transplant with a larger bone stock and a longer ligament may display an advantage, as insertion is possible in the dorsal, easily accessible part of the carpal bones rather than in the arête-like region adjacent to the insertion of the scapholunate ligament. In this study, 1.5 mm lengthening of the bone–ligament–bone transplant was defined as clinical failure, as such elongation will cause severe gapping and is considered as failure of the transplant.
Multiple-level amputations of the upper extremity represent a surgical challenge generally only attempted in young patients. This case demonstrates a successful replantation in an elderly woman. The postoperative course was complicated by disseminated intravascular coagulopathy most likely due to inadequate resuscitation. Hand trauma is often underestimated in its general severity. Upper extremity amputations need to be handled similar to polytraumatized patients.