Refine
Has Fulltext
- yes (99)
Is part of the Bibliography
- yes (99)
Year of publication
- 2018 (99) (remove)
Document Type
- Journal article (72)
- Doctoral Thesis (27)
Keywords
- Parton Distributions (23)
- Hadron-Hadron scattering (experiments) (16)
- Extension (14)
- Decay (13)
- Squark (11)
- ++ (10)
- Mass (7)
- Physics (7)
- Cross-Section (6)
- Gluino Production (6)
Institute
- Physikalisches Institut (99) (remove)
Sonstige beteiligte Institutionen
In der vorliegenden Arbeit wurde angestrebt, die Eigenschaften komplexgekoppelter DFB-Laser bezüglich ihrer Nutzung für metrologische Untersuchungen zu analysieren und zu verbessern.
Hierfür wurden die räumlichen Emissionseigenschaften der lateral komplexgekoppelten DFB-Laser in ausgiebigen Studien diskutiert. Für kommerziell erhältliche Laser wurde daraufhin das Fernfeld sowohl in lateraler als auch vertikaler Richtung berechnet. Die entsprechenden Fernfeldmessungen konnten die Theorie bestätigen und wie erwartet, waren die Divergenzwinkel mit 52° FWHM in der Wachstumsrichtung und 12° FWHM in lateraler Richtung (vgl. Abb. 6.4 und 6.5) sehr unterschiedlich und zeugen von einer großen Differenz in den Fernfeldwinkeln. Mit Überlegungen zu dem optischen bzw. elektrischen Einschlusspotential im Hinblick auf die veränderte Fernfeldsituation wurde zunächst die reine Halbleiterlaserschichtfolge optimiert. Der Divergenzwinkel in Wachstumsrichtung wurde um mehr als 50% auf 25° FWHM gesenkt. Damit konnte die Asymmetrie des Fernfeldes um einen Faktor von mehr als 4 reduziert werden. Strahlgüteuntersuchungen zeigten ein nahezu beugungsbegrenztes Gaußsches Strahlprofil in der langsamen Achse mit einem M2-Wert von 1,13 (Abb. 6.3).
Eine weitere Untersuchung betraf die Linienbreitenabhängigkeit solcher Laser von ihrer Ausgangsleistung, der Resonatorlänge, der Facettenvergütung und der Gitterkopplung. Die erste Beobachtung betraf die Verschmälerung der Linienbreite mit ansteigender Ausgangsleistung bis hin zu einer erneuten Verbreiterung (Rebroadening) der Linienbreite (siehe Abb. 7.3). Der Einfluss auf die Linienbreite durch eine Veränderung der Resonatorlänge ließ sich sehr gut mit der Theorie vergleichen und so erbrachte eine Verdopplung der Resonatorlänge eine Verschmälerung der Linienbreite um mehr als einen Faktor 3. Die Verlängerung der Kavität begünstigte den negativen Effekt des sog. Rebroadenings nicht, da bei der verwendeten Technologie der lateral komplexen Kopplung der Index-Beitrag an der Rückkopplung sehr klein ist. Im Falle reiner Indexkopplung wäre dies durch die veränderte κ · L-Lage deutlich zu spüren. Ein weiterer, oben auch angesprochener Vorteil der komplexen Kopplung ist, dass die Facettenreflektivitäten einen wesentlich kleineren Einfluss auf die DFB-Ausbeute und auf deren Eigenschaften haben als bei der reinen Indexkopplung. Dies lässt sich ausnutzen, um die Photonenlebensdauer in der Kavität zu erhöhen ohne negativ die DFB-Ausbeute zu beeinflussen. In dieser Arbeit wurde bei verschiedenen Längen die reine gebrochene Facette mit einer vergüteten verglichen und der Einfluss auf die Linienbreite analysiert. Die Frontfacette wurde durch eine Passivierung bei ca. 30% gehalten und die Rückfacette durch einen doppelten Reflektor auf ca. 85% gesetzt. Daraus resultierte eine Reduktion der Linienbreite um mehr als die Hälfte.
Neben diesen Ergebnissen wurde auch der Einfluss der komplexen Kopplung untersucht. Da die durch das Gitter zusätzlich eingebrachten Verluste zu einer Vergrößerung der Linienbreiten beitragen, wird bei einem größeren geometrischen Gitterüberlapp das Frequenzrauschen auch entsprechend steigen. Dies ließ sich auch im Experiment bestätigen.
Zudem wurde eine Längenabhängigkeit dieses Effektes festgestellt. Die Reduzierung der Linienbreite bei längeren Bauteilen ist deutlich ausgeprägter als bei kürzeren. So ist bei ähnlicher Verringerung des Gitterüberlappes bei einem 900 μm langen Bauteil eine Linienbreitenreduzierung um einen Faktor von „nur“ 1,85 beobachtbar, aber bei der doppelten Kavitätslänge ist dieser Faktor schon auf 3,60 angestiegen.
Im Rahmen dieser Arbeit wurden DFB-Laser hergestellt, die eine Linienbreite von bis zu 198 kHz aufwiesen. Dies stellt für lateral komplexgekoppelte Laser einen absoluten Rekordwert dar. Im Vergleich zu Index-DFB-Lasern ist dieser Wert bzgl. der Linienbreite mit den aktuellsten Ergebnissen aus der Forschung zu vergleichen [CTR+11], bei welchen eine Linienbreite zu 200 kHz bestimmt wurde.
In dem letzten Abschnitt dieser Arbeit wurde der Einfluss einer veränderten Phasenlage von Gitter und Facette untersucht. Dabei wurden spezielle Bauteile hergestellt (3-Segment-DFB-Laser) und verschiedene Gitterlängen untersucht. Die Phasenlage kann reversibel über den eingestellten Strom in den gitterfreien Segmenten geregelt werden. Wie vorhergesagt, bestätigen die Experimente, dass diese Phasenbeziehung einen signifikanten Einfluss auf die Ausgangsleistung, die Wellenlänge mit ihrer zugehörigen Seitenmodenunterdrückung und auch auf die Linien-breite hat. Bei der Analyse der Linienbreite konnte eindeutig beobachtet werden, dass für die verschiedenen Längen die inverse Linienbreite sehr gut mit der relativen Seitenmodenunterdrückung gekoppelt ist. Dies stellt eine deutliche Erleichterung der zukünftigen Optimierung der komplexgekoppelten DFB-Laser dar, da eine Linienbreitenuntersuchung meist deutlich zeitaufwendiger ist als eine Analyse mit einem optischen Spektrometer.
Herzkreislauferkrankungen stellen die häufigsten Todesursachen in den Industrienationen dar. Die Entwicklung nichtinvasiver Bildgebungstechniken mit Hilfe der Magnetresonanz-Tomografie (MRT) ist daher von großer Bedeutung, um diese Erkrankungen frühzeitig zu erkennen und um die Entstehungsmechanismen zu erforschen. In den letzten Jahren erwiesen sich dabei genetisch modifzierte Mausmodelle als sehr wertvoll, da sich durch diese neue Bildgebungsmethoden entwickeln lassen und sich der Krankheitsverlauf im Zeitraffer beobachten lässt.
Ein große Herausforderung der murinen MRT-Bildgebung sind die die hohen Herzraten und die schnelle Atmung. Diese erfordern eine Synchronisation der Messung mit dem Herzschlag und der Atmung des Tieres mit Hilfe von Herz- und Atemsignalen. Konventionelle Bildgebungstechniken verwenden zur Synchronisation mit dem Herzschlag EKG Sonden, diese sind jedoch insbesondere bei hohen Feldstärken (>3 T) sehr störanfällig. In dieser Arbeit wurden daher neue Bildgebungsmethoden entwickelt, die keine externen Herz- und Atemsonden benötigen, sondern das MRT-Signal selbst zur Bewegungssynychronisation verwenden. Mit Hilfe dieser Technik gelang die Entwicklung neuer Methoden zur Flussbildgebung und der 3D-Bildgebung, mit denen sich das arterielle System der Maus qualitativ und quantitativ erfassen lässt, sowie einer neuen Methode zur Quantisierung der longitudinalen Relaxationszeit T1 im murinen Herzen. Die in dieser Arbeit entwickelten Methoden ermöglichen robustere Messungen des Herzkreislaufsystems. Im letzten Kapitel konnte darüber hinaus gezeigt werden dass sich die entwickelten Bildgebungstechniken in der Maus auch auf die humane Bildgebung übertragen lassen.
This thesis describes the studies of topological superconductivity, which is predicted to
emerge when pair correlations are induced into the surface states of 2D and 3D topolog-
ical insulators (TIs). In this regard, experiments have been designed to investigate the
theoretical ideas first pioneered by Fu and Kane that in such system Majorana bound
states occur at vortices or edges of the system [Phys. Rev. Lett. 100, 096407 (2008), Phys.
Rev. B 79, 161408 (2009)]. These states are of great interest as they constitute a new
quasiparticle which is its own antiparticle and can be used as building blocks for fault
tolerant topological quantum computing.
After an introduction in chapter 1, chapter 2 of the thesis lays the foundation for the
understanding of the field of topology in the context of condensed matter physics with a
focus on topological band insulators and topological superconductors. Starting from a
Chern insulator, the concepts of topological band theory and the bulk boundary corre-
spondence are explained. It is then shown that the low energy Hamiltonian of mercury
telluride (HgTe) quantum wells of an appropriate thickness can be written as two time
reversal symmetric copies of a Chern insulator. This leads to the quantum spin Hall effect.
In such a system, spin-polarized one dimensional conducting states form at the edges
of the material, while the bulk is insulating. This concept is extended to 3D topological
insulators with conducting 2D surface states. As a preliminary step to treating topological
superconductivity, a short review of the microscopic theory of superconductivity, i.e. the
theory of Bardeen, Cooper, and Shrieffer (BCS theory) is presented. The presence of
Majorana end modes in a one dimensional superconducting chain is explained using the
Kitaev model. Finally, topological band insulators and conventional superconductivity
are combined to effectively engineer p-wave superconductivity. One way to investigate
these states is by measuring the periodicity of the phase of the Josephson supercurrent
in a topological Josephson junction. The signature is a 4π-periodicity compared to the
2π-periodicity in conventional Josephson junctions. The proof of the presence of this
effect in HgTe based Josephson junction is the main goal of this thesis and is discussed in
chapters 3 to 6.
Chapter 3 describes in detail the transport of a 3D topological insulator based weak
link under radio-frequency radiation. The chapter starts with a review of the state of
research of (i) strained HgTe as 3D topological insulator and (ii) the progress of induc-
ing superconducting correlations into the topological surface states and the theoretical
predictions of 3D TI based Josephson junctions. Josephson junctions based on strained
HgTe are successfully fabricated. Before studying the ac driven Josephson junctions, the
dc transport of the devices is analysed. The critical current as a function of temperature
is measured and it is possible to determine the induced superconducting gap. Under
rf illumination Shapiro steps form in the current voltage characteristic. A missing first
step at low frequencies and low powers is found in our devices. This is a signature of
a 4π-periodic supercurrent. By studying the device in a wide parameter range - as a
147148 SUMMARY
function of frequency, power, device geometry and magnetic field - it is shown that the
results are in agreement with the presence of a single gapless Andreev doublet and several
conventional modes.
Chapter 4 gives results of the numerical modelling of the I −V dynamics in a Josephson
junction where both a 2π- and a 4π-periodic supercurrents are present. This is done in
the framework of an equivalent circuit representation, namely the resistively shunted
Josephson junction model (RSJ-model). The numerical modelling is in agreement with
the experimental results in chapter 3. First, the missing of odd Shapiro steps can be
understood by a small 4π-periodic supercurrent contribution and a large number of
modes which have a conventional 2π-periodicity. Second, the missing of odd Shapiro
steps occurs at low frequency and low rf power. Third, it is shown that stochastic processes
like Landau Zener tunnelling are most probably not responsible for the 4π contribution.
In a next step the periodicity of Josephson junctions based on quantum spin Hall
insulators using are investigated in chapter 5. A fabrication process of Josephson junctions
based on inverted HgTe quantum wells was successfully developed. In order to achieve a
good proximity effect the barrier material was removed and the superconductor deposited
without exposing the structure to air. In a next step a gate electrode was fabricated which
allows the chemical potential of the quantum well to be tuned. The measurement of the
diffraction pattern of the critical current Ic due to a magnetic field applied perpendicular
to the sample plane was conducted. In the vicinity to the expected quantum spin Hall
phase, the pattern resembles that of a superconducting quantum interference device
(SQUID). This shows that the current flows predominantly on the edges of the mesa.
This observation is taken as a proof of the presence of edge currents. By irradiating the
sample with rf, missing odd Shapiro steps up to step index n = 9 have been observed. This
evidences the presence of a 4π-periodic contribution to the supercurrent. The experiment
is repeated using a weak link based on a non-inverted HgTe quantum well. This material
is expected to be a normal band insulator without helical edge channels. In this device,
all the expected Shapiro steps are observed even at low frequencies and over the whole
gate voltage range. This shows that the observed phenomena are directly connected
to the topological band structure. Both features, namely the missing of odd Shapiro
steps and the SQUID like diffraction pattern, appear strongest towards the quantum spin
Hall regime, and thus provide evidence for induced topological superconductivity in the
helical edge states.
A more direct way to probe the periodicity of the Josephson supercurrent than using
Shapiro steps is the measurement of the emitted radiation of a weak link. This experiment
is presented in chapter 6. A conventional Josephson junction converts a dc bias V to
an ac current with a characteristic Josephson frequency fJ
= eV /h. In a topological
Josephson junction a frequency at half the Josephson frequency fJ /2 is expected. A
new measurement setup was developed in order to measure the emitted spectrum of a
single Josephson junction. With this setup the spectrum of a HgTe quantum well based
Josephson junction was measured and the emission at half the Josephson frequency fJ /2
was detected. In addition, fJ emission is also detected depending on the gate voltage and
detection frequency. The spectrum is again dominated by half the Josephson emission at
low voltages while the conventional emission is determines the spectrum at high voltages.
A non-inverted quantum well shows only conventional emission over the whole gateSUMMARY 149
voltage and frequency range. The linewidth of the detected frequencies gives a measure
on the lifetime of the bound states: From there, a coherence time of 0.3–4ns for the fJ /2
line has been deduced. This is generally shorter than for the fJ line (3–4ns).
The last part of the thesis, chapter 7, reports on the induced superconducting state
in a strained HgTe layer investigated by point-contact Andreev reflection spectroscopy.
For the experiment, a HgTe mesa was fabricated with a small constriction. The diameter
of the orifice was chosen to be smaller than the mean free path estimated from magne-
totransport measurements. Thus one gets a ballistic point-contact which allows energy
resolved spectroscopy. One part of the mesa is covered with a superconductor which
induces superconducting correlations into the surface states of the topological insulator.
This experiment therefore probes a single superconductor normal interface. In contrast to
the Josephson junctions studied previously, the geometry allows the acquisition of energy
resolved information of the induced superconducting state through the measurement
of the differential conductance dI/dV as a function of applied dc bias for various gate
voltages, temperatures and magnetic fields. An induced superconducting order parame-
ter of about 70µeV was extracted but also signatures of the niobium gap at the expected
value around Δ Nb
≈ 1.1meV have been found. Simulations using the theory developed by
Blonder, Tinkham and Klapwijk and an extended model taking the topological surface
states into account were used to fit the data. The simulations are in agreement with a
small barrier at the topological insulator-induced topological superconductor interface
and a high barrier at the Nb to topological insulator interface. To understand the full con-
ductance curve as a function of applied voltage, a non-equilibrium driven transformation
is suggested. The induced superconductivity is suppressed at a certain bias value due to
local electron population. In accordance with this suppression, the relevant scattering
regions change spatially as a function of applied bias.
To conclude, it is emphasized that the experiments conducted in this thesis found
clear signatures of induced topological superconductivity in HgTe based quantum well
and bulk devices and opens up the avenue to many experiments. It would be interesting
to apply the developed concepts to other topological matter-superconductor hybrid
systems. The direct spectroscopy and manipulation of the Andreev bound states using
circuit quantum electrodynamic techniques should be the next steps for HgTe based
samples. This was already achieved in superconducting atomic break junctions by the
group in Saclay [Science 2015, 349, 1199-1202 (2015)]. Another possible development
would be the on-chip detection of the emitted spectrum as a function of the phase φ
through the junction. In this connection, the topological junction needs to be shunted
by a parallel ancillary junction. Such a setup would allow the current phase relation
I(φ) directly and the lifetime of the bound states to be measured directly. By coupling
this system to a spectrometer, which can be another Josephson junction, the energy
dependence of the Andreev bound states E(φ) could be obtained. The experiments on
the Andreev reflection spectroscopy described in this thesis could easily be extended to
two dimensional topological insulators and to more complex geometries, like a phase
bias loop or a tunable barrier at the point-contact. This work might also be useful for
answering the question how and why Majorana bound states can be localized in quantum
spin Hall systems.
Aufgrund der hohen Sensitivität bei der Absorptionsmessung von Gasen im Spektral-
bereich des mittleren Infrarot steigt die Nachfrage nach monolithischen, kompakten
und energieeffizienten Laserquellen in Wellenlängenfenster zwischen 3 und 6 μm ste-
tig. In diesem Bereich liegen zahlreiche Absorptionsbanden von Gasen, welche sowohl
in der Industrie als auch in der Medizintechnik von Relevanz sind. Mittels herkömm-
licher Diodenlaser konnte dieser Bereich bisher nur unzureichend abgedeckt werden,
während Quantenkaskadenlaser infolge ihrer hohen Schwellenleistungen vor allem
für portable Anwendungen nur bedingt geeignet sind. Interbandkaskadenlaser kom-
binieren die Vorteile des Interbandübergangs von konventionellen Diodenlasern mit
der Möglichkeit zur Kaskadierung der Quantenkaskadenlaser und können einen sehr
breiten Spektralbereich abdecken.
Das übergeordnete Ziel der Arbeit war die Optimierung von molekularstrahlepitak-
tisch hergestellten Interbandkaskadenlasern auf GaSb - Basis im Spektralbereich des
mittleren Infrarot für den Einsatz in der Gassensorik. Dies impliziert die Ermögli-
chung von Dauerstrichbetrieb bei Raumtemperatur, das Erreichen möglichst geringer
Schwellenleistungen sowie die Entwicklung eines flexiblen Konzepts zur Selektion von
nur einer longitudinalen Mode.
Da die Qualität der gewachsenen Schichten die Grundvoraussetzung für die Herstel-
lung von performanten Bauteilen darstellt, wurde diese im Rahmen verschiedener
Wachstumsserien eingehend untersucht. Nachdem das Flussverhältnis zwischen den
Gruppe -V Elementen Sb und As ermittelt werden konnte, bei dem die InAs/AlSb -
Übergitter der Mantelschichten verspannungskompensiert hergestellt werden können,
wurde die optimale Substrattemperatur beim Wachstum dieser zu 450 ◦C bestimmt.
Anhand von PL - sowie HRXRD- Messungen an Testproben konnte auch die opti-
male Substrattemperatur beim Wachstum der charakteristischen W- Quantenfilme
zu 450 ◦C festgelegt werden. Als weiterer kritischer Parameter konnte der As - Fluss
beim Wachstum der darin enthaltenen InAs - Schichten identifiziert werden. Die bes-
ten Ergebnisse wurden dabei mit einem As - Fluss von (1.2 ± 0.2) × 10−6 torr erzielt.
Darüber hinaus konnte in Kooperation mit der Technischen Universität Breslau eine sehr hohe guteWachstumshomogenität auf den verwendeten 2′′ großen GaSb -Wafern
nachgewiesen werden.
Im Anschluss an die Optimierung des Wachstums verschiedener funktioneller Be-
standteile wurden basierend auf einem in der Literatur veröffentlichten Laserschicht-
aufbau diverse Variationen mit dem Ziel der Optimierung der Laserkenndaten unter-
sucht. Zum Vergleich wurden 2.0 mm lange und 150 μm breite, durch die aktive Zone
geätzte Breitstreifenlaser herangezogen.
Eine erhebliche Verbesserung der Kenndaten konnte durch die Anwendung des Kon-
zepts des Ladungsträgerausgleichs in der aktiven Zone erreicht werden. Bei einer
Si - Dotierkonzentration von 5.0 × 1018 cm−3 in den inneren vier InAs - Filmen des
Elektroneninjektors konnte die niedrigste Schwellenleistungsdichte von 491W/cm2
erreicht werden, was einer Verbesserung von 59% gegenüber des Referenzlasers ent-
spricht. Mithilfe längenabhängiger Messungen konnte gezeigt werden, dass der Grund
für die Verbesserung in der deutlichen Reduzierung der internen Verluste auf nur
11.3 cm−1 liegt. Weiterhin wurde die Abhängigkeit der Laserkenngrößen von der
Anzahl der verwendeten Kaskaden in den Grenzen von 1 bis 12 untersucht. Wie
das Konzept der Kaskadierung von Quantenfilmen erwarten ließ, wurde eine mo-
notone Steigerung des Anstiegs der Strom - Lichtleistungskennlinie sowie eine Pro-
portionalität zwischen der Einsatzspannung und der Kaskadenzahl nachgewiesen.
Für ICLs mit einer gegebenen Wellenleiterkonfiguration und einer Wellenlänge um
3.6 μm wurde bei einer Temperatur von 20 ◦C mit 326W/cm2 die niedrigste Schwel-
lenleistungsdichte bei einem ICL mit vier Kaskaden erreicht. Des Weiteren konnte
für einen ICL mit 10 Kaskaden und einer Schwellenstromdichte von unter 100A/cm2
ein Bestwert für Halbleiterlaser in diesem Wellenlängenbereich aufgestellt werden.
Eine weitere Reduktion der Schwellenleistungsdichte um 24% konnte anhand von
Lasern mit fünf Kaskaden durch die Reduktion der Te - Dotierung von 3 × 1017 cm−3
auf 4 × 1016 cm−3 im inneren Teil der SCLs erreicht werden. Auch hier wurde mit-
tels längenabhängiger Messungen eine deutliche Reduktion der internen Verluste
nachgewiesen. In einer weiteren Untersuchung wurde der Einfluss der SCL - Dicke
auf die spektralen sowie elektro - optischen Eigenschaften untersucht. Darüber hin-
aus konnten ICLs realisiert werden, deren Mantelschichten nicht aus kurzperiodigen
InAs/AlSb - Übergittern sondern aus quaternärem Al0.85Ga0.15As0.07Sb0.93 bestehen.
Für einen derartig hergestellten ICL konnte eine Schwellenstromdichte von 220A/cm2
bei einer Wellenlänge von 3.4 μm gezeigt werden.
Mithilfe der durch die verschiedenen Optimierungen gewonnenen Erkenntnisse so-
wie Entwurfskriterien aus der Literatur wurden im Rahmen diverser internationaler Kooperationsprojekte ICLs bei verschiedenen Wellenlängen zwischen 2.8 und 5.7 μm
hergestellt. Der Vergleich der Kenndaten zeigt einen eindeutigen Trend zu einer stei-
genden Schwellenstromdichte mit steigender Wellenlänge. Die charakteristische Tem-
peratur der untersuchten Breitstreifenlaser nimmt von circa 65K bei lambda=3.0 μm mit
steigender Wellenlänge auf ein Minimum von 35K im Wellenlängenbereich um 4.5 μm
ab und steigt mit weiter steigender Wellenlänge wieder auf 45K an. Ein möglicher
Grund für dieses Verhalten konnte mithilfe von Simulationen in der Anordnung der
Valenzbänder im W-Quantenfilm gefunden werden.
Zur Untersuchung der Tauglichkeit der epitaktisch hergestellten Schichten für den in
der Anwendung hilfreichen Dauerstrichbetrieb oberhalb von Raumtemperatur wur-
den Laser in Stegwellenleitergeometrie mit einer aufgalvanisierten Goldschicht zur
verbesserten Wärmeabfuhr hergestellt. Nach dem Aufbau der Laser auf Wärmesen-
ken wurde der Einfluss der Kavitätslänge sowie der Stegbreite auf diverse Kennda-
ten untersucht. Des Weiteren wurden eine Gleichung verifiziert, welche es erlaubt
die maximal erreichbare Betriebstemperatur im Dauerstrichbetrieb aus der auf die
Schwellenleistung bezogenen charakteristischen Temperatur sowie dem thermischen
Widerstand des Bauteils zu berechnen. Mithilfe von optimierten Bauteilen konn-
ten Betriebstemperaturen von mehr als 90 ◦C und Ausgangsleistungen von mehr als
100mW bei einer Betriebstemperatur von 20 ◦C erreicht werden.
Im Hinblick auf die Anwendung der Laser in der Absorptionsspektroskopie wurde ab-
schließend ein DFB-Konzept, welches zuvor bereits in konventionellen Diodenlasern
zur Anwendung kam, erfolgreich auf das ICL - Material übertragen. Dabei kommt
ein periodisches Metallgitter zum Einsatz, welches seitlich der geätzten Stege aufge-
bracht wird und aufgrund von Verlustkopplung eine longitudinale Mode bevorzugt.
Durch den Einsatz von unterschiedlichen Gitterperioden konnten monomodige ICLs
basierend auf dem selben Epitaxiematerial in einem spektralen Bereich von mehr als
100nm hergestellt werden. Ein 2.4mm langer DFB- Laser konnte einen Abstimmbe-
reich von mehr als 10nm bei Verschiebungsraten von 0.310nm/K und 0.065nm/mA
abdecken. Der DFB- ICL zeigte im Dauerstrichbetrieb in einem Temperaturbereich
zwischen 10 und 35 ◦C monomodigen Betrieb mit einer Ausgangsleistung von mehre-
ren mW. Basierend auf dem in dieser Arbeit gewachsenem Material und dem DFB-
Konzept konnte im Rahmen verschiedener Entwicklungsprojekte bereits erfolgreich
Absorptionsspektroskopie in einem breiten Spektralbereich des mittleren Infrarot be-
trieben werden.
Der Übergang vom der ersten Phase der Lehramtsausbildung ins Referendariat wird häufig mit dem Begriff „Praxisschock“ verbunden. Viele Studierende und Referendare fühlen sich unzureichend auf den Unterricht in der Schule vorbereitet. Sie fordern deshalb eine stärkere Verzahnung von Theorie und Praxis, also eine Anwendung der erlernten Theorien in „echten“ Praxisphasen auch schon in der ersten Phase der Lehramtsausbildung.
Das Lehr-Lern-Labor Seminar der Universität Würzburg kann dazu beitragen, diese Verbindung von Theorie und Praxis herzustellen. Grundlegend sollen die Studierenden in diesem Seminar ihr fachliches, didaktisches und pädagogisches (Vor-)Wissen aufgreifen und in komplexitätsreduzierten Handlungsumgebungen anwenden. Dabei sollen sie im Rahmen des Lehr-Lern-Labor Seminars zunächst Experimentierstationen zu vorgegebenen Themengebieten aus dem bayerischen Lehrplan konzipieren, um anschließend mehrmals Schülerinnen und Schüler an diesen Stationen zu betreuen. Im Sinne einer iterativen Praxis werden die Betreuungen mehrmals von den Studierenden zusammen mit zwei Dozenten reflektiert. Letztlich wiederholen sich die Betreuungen, die Reflexionsphasen und mögliche Verbesserungen der Stationen viermal in einem zyklischen Prozess.
Für die Verknüpfung von theoretischem Wissen in konkreten Handlungssituationen sind Wahrnehmungsprozesse von Bedeutung. Die sogenannte Professionelle Unterrichts-wahrnehmung beschreibt die Fähigkeit, relevante Unterrichtssituationen zu erkennen und theoriebezogen zu bewerten. Sie verknüpft das zugrunde liegende Wissen mit konkreten Handlungssituationen und dient somit als Bindeglied zwischen dem Wissen und dem Handeln, welches speziell in Reflexionsphasen gefördert werden kann.
Durch die mehrmaligen Reflexionsprozesse der eigenen Betreuungen und die der Kommilitonen im Lehr-Lern-Labor Seminar könnte es eine vielversprechende Grundlage zur Förderung der Professionellen Unterrichtswahrnehmung darstellen. Die grundlegende Fragestellung der vorliegenden Arbeit ist es daher zu untersuchen, ob sich die Professionelle Unterrichtswahrnehmung im Rahmen des Lehr-Lern-Labor Seminars fördern lässt und inwieweit neu integrierte Videoanalysen der eigenen Betreuungen und die der Kommilitonen die Professionelle Unterrichtswahrnehmung der Studierenden zusätzlich fördern. Weiterhin interessiert, ob personenspezifische Merkmale einen zusätzlichen Einfluss auf die Entwicklung der Professionellen Unterrichtswahrnehmung ausüben.
Ergänzend wird untersucht, ob zwischen dem Fachwissen, dem didaktischen Wissen und der Professionellen Unterrichtswahrnehmung Zusammenhänge bestehen. Dies könnte Aufschluss darauf geben, inwieweit Fachwissen und didaktisches Wissen die Entwicklung der Professionellen Unterrichtswahrnehmung im Seminar bedingen.
Diese Arbeit leistet somit einen wichtigen Beitrag zur Untersuchung der Wirksamkeit eines Lehr-Lern-Labor Seminars, welches in die Ausbildung von Physiklehrkräften integriert wurde und zeigt auf, wie das Seminar bezüglich der Förderung der Professionellen Unterrichtswahrnehmung effektiver gestaltet werden kann.
Molekularstrahlepitaxie von niederdimensionalen GaInAs(N) Systemen für AlGaAs Mikroresonatoren
(2018)
Die Erforschung von Quantenpunkten mit ihren quantisierten, atomähnlichen Zuständen, bietet eine Vielzahl von Möglichkeiten auf dem Weg zum Quantencomputer und für Anwendungen wie Einzelphotonenquellen und Quantenpunktlasern. Vorangegangene Studien haben grundlegend gezeigt, wie Quantenpunkte in Halbleiterresonatoren integriert und mit diesen gekoppelt werden können. Dazu war es zum einen notwendig, die Quantenpunkte und ihr epitaktisches Wachstum besser zu verstehen und zu optimieren. Zum anderen mussten die Bragg-Resonatoren optimiert werden, sodass Güten von bis zu 165.000 realisiert werden konnten. Eingehende Studien dieser Proben zeigten im Anschluss einen komplexeren Zusammenhang von Q-Faktor und Türmchendurchmesser. Man beobachtet eine quasi periodische Oszillation des Q-Faktors mit dem Pillar Durchmesser. Ein Faktor für diese Oszillation ist die Beschaffenheit der Seitenflanken des Resonatortürmchens, bedingt durch die unterschiedlichen Eigenschaften von AlAs und GaAs bei der Prozessierung der Türmchen. Darüber hinaus wurden in der Folge auf den Grundlagen dieser Strukturen sowohl optisch als auch elektrisch gepumpte Einzelphotonenquellen realisiert.
Da in diesen Bauteilen auch die Lage des Quantenpunkts innerhalb des Resonatortürmchens einen erheblichen Einfluss auf die Effizienz der Kopplung zwischen Resonator und Quantenpunkt hat, war das weitere Ziel, die Quantenpunkte kontrolliert zu positionieren. Mit einer gezielten Positionierung sollte es möglich sein, ein Resonatortürmchen direkt über dem Quantenpunkt zu plazieren und den Quantenpunkt somit in das Maximum der optischen Mode zu legen.
Besondere Herausforderung für die Aufgabenstellung war, Quantenpunkte in einem Abstand von mind. der Hälfte des angestrebten Türmchendurchmessers, d.h 0,5 μm bis 2 μm, zu positionieren. Die Positionierung musste so erfolgen, dass nach dem Wachstum eines AlAs/GaAs DBR Spiegel über den Quantenpunkten, Resonatortürmchen zielgenau auf die Quantenpunkte prozessiert werden können. Es wurden geeignete Prozesse zur Strukturierung eines Lochgitters in die epitaktisch gewaschene Probe mittels Elektronenstrahllithographie entwickelt. Für ein weiteres Wachstum mittels Molekularstrahlepitaxie, mussten die nasschemischen Reinigungsschritte sowie eine Reinigung mit aktivem Wasserstoff im Ultrahochvakuum optimiert werden, sodass die Probe möglichst defektfrei überwachsen werden konnte, die Struktur des Lochgitters aber nicht zerstört wurde. Es wurden erfolgreich InAs-Quantenpunkte auf die vorgegebene Struktur positioniert, erstmals in einem Abstand von mehreren Mikrometern zum nächsten Nachbarn. Eine besondere Herausforderung war die Vorbereitung für eine weitere Prozessierung der Proben nach Quantenpunktwachstum. Eine Analyse mittels prozessierten Goldkreuzen, dass 30 % der Quantenpunkte innerhalb von 50 nm und 60 % innerhalb von 100 nm prozessiert wurden. In der Folge wurde mit der hier erarbeiteten Methode Quantenpunkte erfolgreich in DBR-Resonatoren sowie photonische Kristalle eingebaut
Die gute Abstimmbarkeit von Quantenpunkten und die bereits gezeigte Möglichkeit, diese in Halbleiterresonatoren einbinden zu können, machen sie auch interessant für die Anwendung im Telekommunikationsbereich. Um für Glasfasernetze Anwendung zu finden, muss jedoch die Wellenlänge auf den Bereich von 1300 nm oder 1550 nm übertragen werden. Vorangegangene Ergebnisse kamen allerdings nur knapp an die Wellenlänge von 1300nm. Eine fu ̈r andere Bauteile sowie für Laserdioden bereits häufig eingesetzte Methode, InAs-Quantenpunkte in den Bereich von Telekommunikationswellenla ̈ngen zu verschieben, ist die Verwendung von Stickstoff als weiteres Gruppe-V-Element. Bisherige Untersuchungen fokussierten sich auf Anwendungen in Laserdioden, mit hoher Quantenpunktdichte und Stickstoff sowohl in den Quantenpunkten als in den umgebenen Strukturen. Da InAsN-Quantenpunkte in ihren optischen Eigenschaften durch verschiedene Verlustmechanismen leiden, wurde das Modell eines Quantenpunktes in einem Wall (Dot-in-Well) unter der Verwendung von Stickstoff weiterentwickelt. Durch gezielte Separierung der Quantenpunkte von den stickstoffhaltigen Schichten, konnte e eine Emission von einzelnen, MBE-gewachsenen InAs Quantenpunkten von über 1300 nm gezeigt werden. Anstatt den Stickstoff direkt in die Quantenpunkte oder unmittelbar danach in die Deckschicht ein zu binden, wurde eine Pufferschicht ohne Stickstoff so angepasst, dass die Quantenpunkte gezielt mit Wellenlängen größer 1300 nm emittieren. So ist es nun möglich, die Emission von einzelnen InAs Quantenpunkten jenseits dieser Wellenlänge zu realisieren.
Es ist nun daran, diese Quantenpunkte mit den beschriebenen Mikroresonatoren zu koppeln, um gezielt optisch und elektrisch gepumpte Einzelphotonenquellen für 1300nm zu realisieren.
Micromegas are parallel-plate gaseous detectors with micro-pattern readout structures that are able to measure precisely and efficiently at high particle rates. Their difference with respect to other gaseous detectors is that the space in which particles ionise the gas and create electrons is separated from the region in which these electrons are multiplied (or amplified) by a thin metallic mesh. In the ionisation region, typically a few mm thick, a moderate field of a few hundred V/cm is applied. The amplification region with a homogeneous electrical field of 40--50~kV/cm is only 100--150~$\upmu$m thick. The latter guarantees that the positive ions produced in the amplification process are rapidly evacuated and the possibility to build up space charge at high rate is reduced. Critical in micromegas detectors are sparks in the thin amplification region in the presence of the high electrical field. This problem was solved in 2011 by introducing a spark protection scheme. It consists of a layer of resistive strips on top of the readout strips, separated from the latter by a thin insulation layer.
Micromegas with the spark protection scheme were selected as instrumentation of the first ATLAS forward muon station (NSW) in the upgrade of the ATLAS detector for the operation of the Large Hadron Collider (LHC) at high luminosity (HL-LHC), expected for 2026.
The main subjects of this thesis are: the characterisation of the first micromegas quadruplet prototypes for the NSW detectors; the characterisation of the materials used in the spark-protection system; and the study of the influence of the mesh distance holders (pillars) on the detector performance.
The thesis starts with a brief introduction into the LHC and ATLAS projects, followed by a chapter that explains the reason for the upgrade of the ATLAS muon system and shows the layout of the NSW.
The first of the three main chapters covers the construction and the characterisation of the first two prototypes for the NSW detectors. These detectors comprise four detection layers and have the same mechanical structure as the NSW detectors. The mechanical precision as well as the homogeneity of the detector response are discussed. The latter has been measured using X-rays and cosmic rays. The spatial resolution that can be achieved with these detectors precision has been measured at the MAMI accelerator at Mainz with low-energy electrons. The chapter is completed by a section that describes the successful integration of a data acquisition system (DAQ) into the official ATLAS DAQ system that was required for an initially planned installation of one of the prototypes on the existing Small Wheel.
The next chapter presents a study of the influence of temperature and humidity changes on the resistive strips used in the spark protection system. In addition the long-term stability of the resistive material has been measured accumulating charge equivalent to 100 years of operation in the HL-LHC and exposing the samples to intense gamma irradiation equivalent to 10 years of HL-LHC operation.
The third part covers the impact of the mesh distance holders (pillars) on the performance of the detector. This study has been performed with a 10 x 10 cm$^2$ bulk-micromegas with two different pillar shapes. Both 5.9 keV gammas from a $^{55}$Fe and 8 keV X-rays from a Cu target were used. In this context also the electrostatic charge-up of the detector is discussed.
In the Appendices one finds a summary of the fundamental physics relevant for gaseous detectors as well as some supporting material for the topics covered in the main part of the thesis.
Röntgencomputertomographie (CT) hat in ihrer industriellen Anwendung ein sehr breites Spektrum möglicher Prüfobjekte. Ziel einer CT-Messung sind dreidimensionale Abbilder der Verteilung des Schwächungskoeffizienten der Objekte mit möglichst großer Genauigkeit. Die Parametrierung eines CT-Systems für ein optimales Messergebnis hängt stark vom zu untersuchenden Objekt ab. Eine Vorhersage der optimalen Parameter muss die physikalischen Wechselwirkungen mit Röntgenstrahlung des Objektes und des CT-Systems berücksichtigen. Die vorliegende Arbeit befasst sich damit, diese Wechselwirkungen zu modellieren und mit der Möglichkeit den Prozess zur Parametrierung anhand von Gütemaßen zu automatisieren. Ziel ist eine simulationsgetriebene, automatische Parameteroptimierungsmethode, welche die Objektabhängigkeit berücksichtigt. Hinsichtlich der Genauigkeit und der Effizienz wird die bestehende Röntgensimulationsmethodik erweitert. Es wird ein Ansatz verfolgt, der es ermöglicht, die Simulation eines CT-Systems auf reale Systeme zu kalibrieren. Darüber hinaus wird ein Modell vorgestellt, welches zur Berechnung der zweiten Ordnung der Streustrahlung im Objekt dient. Wegen des analytischen Ansatzes kann dabei auf eine Monte-Carlo Methode verzichtet werden. Es gibt in der Literatur bisher keine eindeutige Definition für die Güte eines CT-Messergebnisses. Eine solche Definition wird, basierend auf der Informationstheorie von Shannon, entwickelt. Die Verbesserungen der Simulationsmethodik sowie die Anwendung des Gütemaßes zur simulationsgetriebenen Parameteroptimierung werden in Beispielen erfolgreich angewendet beziehungsweise mittels Referenzmethoden validiert.
Coherent two-dimensional (2D) optical spectroscopy has revolutionized our ability to probe many types of couplings and ultrafast dynamics in complex quantum systems. The dynamics and function of any quantum system strongly depend on couplings to the environment. Thus, studying coherent interactions for different environments remains a topic of tremendous interest. Here we introduce coherent 2D electronic mass spectrometry that allows 2D measurements on effusive molecular beams and thus on quantum systems with minimum system-bath interaction and employ this to identify the major ionization pathway of 3d Rydberg states in NO2. Furthermore, we present 2D spectra of multiphoton ionization, disclosing distinct differences in the nonlinear response functions leading to the ionization products. We also realize the equivalent of spectrally resolved transient-absorption measurements without the necessity for acquiring weak absorption changes. Using time-of-flight detection introduces cations as an observable, enabling the 2D spectroscopic study on isolated systems of photophysical and photochemical reactions.
The validity of Kirchhoff’s laws in plasmonic nanocircuitry is investigated by studying a junction of plasmonic two-wire transmission lines. We find that Kirchhoff’s laws are valid for sufficiently small values of a phenomenological parameter κ relating the geometrical parameters of the transmission line with the effective wavelength of the guided mode. Beyond such regime, for large values of the phenomenological parameter, increasing deviations occur and the equivalent impedance description (Kirchhoff’s laws) can only provide rough, but nevertheless useful, guidelines for the design of more complex plasmonic circuitry. As an example we investigate a system composed of a two-wire transmission line and a nanoantenna as the load. By addition of a parallel stub designed according to Kirchhoff’s laws we achieve maximum signal transfer to the nanoantenna.
In this work, functional plasmonic nanocircuitry is examined as a key of revolutionizing state-of-the-art electronic and photonic circuitry in terms of integration density and transmission bandwidth. In this context, numerical simulations enable the design of dedicated devices, which allow fundamental control of photon flow at the nanometer scale via single or multiple plasmonic eigenmodes. The deterministic synthesis and in situ analysis of these eigenmodes is demonstrated and constitutes an indispensable requirement for the practical use of any device. By exploiting the existence of multiple eigenmodes and coherence - both not accessible in classical electronics - a nanoscale directional coupler for the ultrafast spatial and spatiotemporal coherent control of plasmon propagation is conceived. Future widespread application of plasmonic nanocircuitry in quantum technologies is boosted by the promising demonstrations of spin-optical and quantum plasmonic nanocircuitry.
In Magnetic Resonance Imaging (MRI), acquisition of dynamic data may be highly complex due to rapid changes occurred in the object to be imaged. For clinical diagnostic, dynamic MR images require both high spatial and temporal resolution. The speed in the acquisition is a crucial factor to capture optimally dynamics of the objects to obtain accurate diagnosis. In the 90’s, partially parallel MRI (pMRI) has been introduced to shorten scan times reducing the amount of acquired data. These approaches use multi-receiver coil arrays to acquire independently and simultaneously the data.
Reduction in the amount of acquired data results in images with aliasing artifacts. Dedicated methods as such Sensitivity Encoding (SENSE) and Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) were the basis of a series of algorithms in pMRI.
Nevertheless, pMRI methods require extra spatial or temporal information in order to optimally reconstruct the data. This information is typically obtained by an extra scan or embedded in the accelerated acquisition applying a variable density acquisition scheme.
In this work, we were able to reduce or totally eliminate the acquisition of the training data for kt-SENSE and kt-PCA algorithms obtaining accurate reconstructions with high temporal fidelity.
For dynamic data acquired in an interleaved fashion, the temporal average of accelerated data can generate an artifact-free image used to estimate the coil sensitivity maps avoiding the need of extra acquisitions. However, this temporal average contains errors from aliased components, which may lead to signal nulls along the spectra of reconstructions when methods like kt-SENSE are applied. The use of a GRAPPA filter applied to the temporal average reduces these errors and subsequently may reduce the null components in the reconstructed data. In this thesis the effect of using temporal averages from radial data was investigated. Non-periodic artifacts performed by undersampling radial data allow a more accurate estimation of the true temporal average and thereby avoiding undesirable temporal filtering in the reconstructed images. kt-SENSE exploits not only spatial coil sensitivity variations but also makes use of spatio-temporal correlations in order to separate the aliased signals. Spatio-temporal correlations in kt-SENSE are learnt using a training data set, which consists of several central k-space lines acquired in a separate scan. The scan of these extra lines results in longer acquisition times even for low resolution images. It was demonstrate that limited spatial resolution of training data set may lead to temporal filtering effects (or temporal blurring) in the reconstructed data.
In this thesis, the auto-calibration for kt-SENSE was proposed and its feasibility was tested in order to completely eliminate the acquisition of training data. The application of a prior TSENSE reconstruction produces the training data set for the kt-SENSE algorithm. These training data have full spatial resolution. Furthermore, it was demonstrated that the proposed auto-calibrating method reduces significantly temporal filtering in the reconstructed images compared to conventional kt-SENSE reconstructions employing low resolution training images. However, the performance of auto-calibrating kt-SENSE is affected by the Signal-to-Noise Ratio (SNR) of the first pass reconstructions that propagates to the final reconstructions.
Another dedicated method used in dynamic MRI applications is kt-PCA, that was first proposed for the reconstruction of MR cardiac data. In this thesis, kt-PCA was employed for the generation of spatially resolved M0, T1 and T2 maps from a single accelerated IRTrueFISP or IR-Snapshot FLASH measurement. In contrast to cardiac dynamic data, MR relaxometry experiments exhibit signal at all temporal frequencies, which makes their reconstruction more challenging. However, since relaxometry measurements can be represented by only few parameters, the use of few principal components (PC) in the kt-PCA algorithm can significantly simplify the reconstruction. Furthermore, it was found that due to high redundancy in relaxometry data, PCA can efficiently extract the required information from just a single line of training data.
It has been demonstrated in this thesis that auto-calibrating kt-SENSE is able to obtain high temporal fidelity dynamic cardiac reconstructions from moderate accelerated data avoiding the extra acquisition of training data. Additionally, kt-PCA has been proved to be a suitable method for the reconstruction of highly accelerated MR relaxometry data.
Furthermore, a single central training line is necessary to obtain accurate reconstructions. Both reconstruction methods are promising for the optimization of training data acquisition and seem to be feasible for several clinical applications.
Die vorliegende Arbeit beschäftigt sich mit optoelektronischer Transportspektroskopie verschiedener Resonanztunneldioden (RTDs). Die Arbeit ist thematisch in zwei Schwerpunktee untergliedert. Im ersten Schwerpunkt werden anhand GaAs-basierter RTD-Fotosensoren für den Telekommunikationswellenlängenbereich um 1,3 µm die Akkumulationsdynamiken photogenerierter Minoritätsladungsträger und deren Wirkung auf den RTD-Tunnelstrom untersucht. Im zweiten Schwerpunkt werden GaSb-basierte Al(As)Sb/GaSb-Doppelbarrieren-Quantentrog-RTDs in Hinblick auf ihren Raumtemperaturbetrieb entwickelt und erforscht. Diese legen den Grundstein für die spätere Realisation von RTD-Fotodetektoren im mittleren infraroten (MIR) Spektralbereich. Im Folgenden ist eine kurze inhaltliche Zusammenfassung der einzelnen Kapitel gegeben.
Kapitel 1 leitet vor dem Hintergrund eines stark steigenden Bedarfs an verlässlichen und sensitiven Fotodetektoren für Telekommunikationsanwendungen sowie für die optische Molekül- und Gasspektroskopie in das übergeordnete Thema der RTD-Fotodetektoren ein.
Kapitel 2 erläutert ausgewählte physikalische und technische Grundlagen zu RTD-Fotodetektoren. Ausgehend von einem kurzem Überblick zu RTDs, werden aktuelle Anwendungsgebiete aufgezeigt und die physikalischen Grundlagen elektrischen Transports in RTDs diskutiert. Anschließend werden Grundlagen, Definitionen und charakteristische Kenngrößen optischer Detektoren und Sensoren definiert. Abschließend werden die physikalischen Grundlagen zum Fotostrom in RTDs beschrieben.
In Kapitel 3 RTD-Fotosensor zur Lichtdetektion bei 1,3 µm werden AlGaAs/GaAs-Doppelbarrieren-Quantentrog-Resonanztunneldioden (DBQW-RTDs) mit gitterangepasster, quaternärer GaInNAs-Absorptionsschicht als Raumtemperatur-Fotodetektoren für den nahen infraroten (NIR) Spektralbereich bei der Telekommunikationswellenlänge von λ=1,3 µm untersucht. RTDs sind photosensitive Halbleiterbauteile, die innerhalb der vergangenen Jahre aufgrund ihrer hohen Fotosensitivität und Fähigkeit selbst einzelne Photonen zu detektieren, ein beachtliches Interesse geweckt haben. Die RTD-Fotosensitivität basiert auf einer Coulomb-Wechselwirkung photogenerierter und akkumulierter Ladungsträger. Diese verändern das lokale elektrostatische Potential und steuern so einen empfindlichen Resonanztunnelstrom. Die Kenntnis der zugrundeliegenden physikalischen Parameter und deren Spannungsabhängigkeit ist essentiell, um optimale Arbeitspunkte und Bauelementdesigns zu identifizieren.
Unterkapitel 3.1 gibt einen Überblick über das Probendesign der untersuchten RTD-Fotodetektoren, deren Fabrikationsprozess sowie eine Erläuterung des Fotodetektionsmechanismus. Über Tieftemperatur-Elektrolumineszenz-Spektroskopie wird die effektive RTD-Quantentrog-Breite zu d_DBQW≃3,4 nm bestimmt. Die Quantisierungsenergien der Elektron- und Schwerloch-Grundzustände ergeben sich zu E_Γ1≈144 meV und E_hh1≈39 meV. Abschließend wird der in der Arbeit verwendeten Messaufbau skizziert.
In Unterkapitel 3.2 werden die physikalischen Parameter, die die RTD-Fotosensitivität bestimmen, auf ihre Spannungsabhängigkeit untersucht. Die Fotostrom-Spannungs-Kennlinie des RTD-Fotodetektors ist nichtlinear und über drei spannungsabhängige Parametern gegeben: der RTD-Quanteneffizienz η(V), der mittleren Lebensdauer photogenerierter und akkumulierter Minoritätsladungsträger (Löcher) τ(V) und der RTD-I(V)-Kennlinie im Dunkeln I_dark (V). Die RTD Quanteneffizienz η(V) kann über eine Gaußsche-Fehlerfunktion modelliert werden, welche beschreibt, dass Lochakkumulation erst nach Überschreiten einer Schwellspannung stattfindet. Die mittlere Lebensdauer τ(V) fällt exponentiell mit zunehmender Spannung V ab. Über einen Vergleich mit thermisch limitierten Lebensdauern in Quantentrögen können Leitungsband- und Valenzband-Offset zu Q_C \≈0,55 und Q_V≈0,45 abgeschätzt werden. Basierend auf diesen Ergebnissen wird ein Modell für die Fotostrom-Spannungs-Kennlinie erstellt, das eine elementare Grundlage für die Charakterisierung von RTD-Photodetektoren bildet.
In Unterkapitel 3.3 werden die physikalischen Parameter, die die RTD-Fotosensitivität beschränken, detailliert auf ihre Abhängigkeit gegenüber der einfallenden Lichtleistung untersucht. Nur für kleine Lichtleistungen wird eine konstante Sensitivität von S_I=5,82×〖10〗^3 A W-1 beobachtet, was einem Multiplikationsfaktor von M=3,30×〖10〗^5 entspricht. Für steigende Lichtleistungen fällt die Sensitivität um mehrere Größenordnungen ab. Die abfallende, nichtkonstante Sensitivität ist maßgeblich einer Reduktion der mittleren Lebensdauer τ zuzuschreiben, die mit steigender Lochpopulation exponentiell abfällt. In Kombination mit den Ergebnissen aus Unterkapitel 3.2 wird ein Modell der RTD-Fotosensitivität vorgestellt, das die Grundlage einer Charakterisierung von RTD-Fotodetektoren bildet. Die Ergebnisse können genutzt werden, um die kritische Lichtleistung zu bestimmen, bis zu der der RTD-Fotodetektor mit konstanter Sensitivität betrieben werden kann, oder um den idealen Arbeitspunkt für eine minimale rauschäquivalente Leistung (NEP) zu identifizieren. Dieser liegt für eine durch theoretisches Schrotrauschen limitierte RTD bei einem Wert von NEP=1,41×〖10〗^(-16) W Hz-1/2 bei V=1,5 V.
In Kapitel 4 GaSb-basierte Doppelbarrieren-RTDs werden unterschiedliche Al(As)Sb/GaSb-DBQW-RTDs auf ihre elektrische Transporteigenschaften untersucht und erstmalig resonantes Tunneln von Elektronen bei Raumtemperatur in solchen Resonanztunnelstrukturen demonstriert. Unterkapitel 4.1 beschreibt den Wachstums- und der Fabrikationsprozess der untersuchten AlAsSb/GaSb-DBQW-RTDs.
In Unterkapitel 4.2 wird Elektronentransport durch eine AlSb/GaSb-DBQW-Resonanztunnelstruktur untersucht. Bei einer Temperatur von T=4,2 K konnte resonantes Tunneln mit bisher unerreicht hohen Resonanz-zu-Talstrom-Verhältnisse von PVCR=20,4 beobachtet werden. Dies wird auf die exzellente Qualität des Halbleiterkristallwachstums und des Fabrikationsprozesses zurückgeführt. Resonantes Tunneln bei Raumtemperatur konnte hingegen nicht beobachtet werden. Dies wird einer Besonderheit des Halbleiters GaSb zugeschrieben, welche dafür sorgt, dass bei Raumtemperatur die Mehrheit der Elektronen Zustände am L-Punkt anstelle des Γ Punktes besetzt. Resonantes Tunneln über den klassischen Γ Γ Γ-Tunnelpfad ist so unterbunden.
In Unterkapitel 4.3 werden die elektrischen Transporteigenschaften von AlAsSb/GaSb DBQW RTDs mit pseudomorph gewachsenen ternären Vorquantentopfemittern untersucht. Der primäre Zweck der Vorquantentopfstrukturen liegt in der Erhöhung der Energieseparation zwischen Γ- und L-Punkt. So kann Elektronentransport über L- Kanäle unterdrückt und Elektronenzustände am Γ-Punkt wiederbevölkert werden. Zudem ist bei genügend tiefen Vorquantentopfstrukturen aufgrund von Quantisierungseffekten eine Verbesserung der RTD-Transporteigenschaften möglich. Strukturen ohne Vorquantentopf-Emitter zeigen ein Tieftemperatur- (T=77 K) Resonanz-zu-Talstrom-Verhältnis von PVCR=8,2, während bei Raumtemperatur kein resonantes Tunneln beobachtet werden kann. Die Integration von Ga0,84In0,16Sb- beziehungsweise GaAs0,05Sb0,95-Vorquantentopfstrukturen führt zu resonantem Tunneln bei Raumtemperatur mit Resonanz-zu-Talstrom-Verhältnissen von PVCR=1,45 und 1,36.
In Unterkapitel 4.4 wird die Abhängigkeit der elektrischen Transporteigenschaften von AlAsSb/GaSb RTDs vom As-Stoffmengenanteil des GaAsSb-Emitter-Vorquantentopfs und der AlAsSb-Tunnelbarriere untersucht. Eine Erhöhung der As-Stoffmengenkonzentration führt zu einem erhöhten Raumtemperatur-PVCR mit Werten von bis zu 2,36 bei gleichzeitig reduziertem Tieftemperatur-PVCR. Das reduzierte Tieftemperatur-Transportvermögen wird auf eine mit steigendem As-Stoffmengenanteil zunehmend degradierende Kristallqualität zurückgeführt.
In Kapitel 5 AlAsSb/GaSb-RTD-Fotosensoren zur MIR-Lichtdetektion werden erstmalig RTD-Fotodetektoren für den MIR-Spektralbereich vorgestellt und auf ihre optoelektronischen Transporteigenschaften hin untersucht. Zudem wird erstmalig ein p-dotierter RTD-Fotodetektor demonstriert. In Unterkapitel 5.1 wird das Probendesign GaSb-basierter RTD-Fotodetektoren für den mittleren infraroten Spektralbereich vorgestellt. Im Speziellen werden Strukturen mit umgekehrter Ladungsträgerpolarität (p- statt n-Dotierung, Löcher als Majoritätsladungsträger) vorgestellt.
In Unterkapitel 5.2 werden die optischen Eigenschaften der gitterangepassten quaternären GaInAsSb-Absorptionsschicht mittels Fourier-Transformations-Infrarot-Spektroskopie untersucht. Über das Photolumineszenz-Spektrum wird die Bandlückenenergie zu E_Gap≅(447±5) meV bestimmt. Das entspricht einer Grenzwellenlänge von λ_G≅(2,77±0,04) µm. Aus dem niederenergetischen monoexponentiellem Abfall der Linienform wird eine Urbach-Energie von E_U=10 meV bestimmt. Der hochenergetische Abfall folgt der Boltzmann-Verteilungsfunktion mit einem Abfall von k_B T=25 meV.
In Unterkapitel 5.3 werden die elektrischen Transporteigenschaften der RTD-Fotodetektoren untersucht und mit denen einer n-dotierten Referenzprobe verglichen. Erstmalig wird resonantes Tunneln von Löchern in AlAsSb/GaSb-DBQW-RTDs bei Raumtemperatur demonstriert. Dabei ist PVCR=1,58. Bei T=4,2 K zeigen resonantes Loch- und Elektrontunneln vergleichbare Kenngrößen mit PVCR=10,1 und PVCR=11,4. Die symmetrische I(V)-Kennlinie der p-dotierten RTD-Fotodetektoren deutet auf eine geringe Valenzbanddiskontinuität zwischen GaSb und der GaInAsSb-Absorptionsschicht hin. Zudem sind die p-dotierten RTDs besonders geeignet für eine spätere Integration mit Typ-II-Übergittern.
In Unterkapitel 5.4 werden die optoelektronischen Transporteigenschaften p-dotierter RTD-Fotodetektoren untersucht. Das vorgestellte neuartige RTD-Fotodetektorkonzept, welches auf resonanten Lochtransport als Majoritätsladungsträger setzt, bietet speziell im für den MIR-Spektralbereich verwendeten GaSb-Materialsystem Vorteile, lässt sich aber auch auf das InP- oder GaAs- Materialsystem übertragen. Die untersuchten p-dotierten Fotodetektoren zeigen eine ausgeprägte Fotosensitivität im MIR-Spektralbereich. Fotostromuntersuchungen werden für optische Anregung mittels eines Halbleiterlasers der Wellenlänge λ=2,61 µm durchgeführt. Bei dieser Wellenlänge liegen fundamentale Absorptionslinien atmosphärischen Wasserdampfs. Die Fotostrom-Spannungs-Charakteristik bestätigt, dass die Fotosensitivität auf einer Modulation des resonanten Lochstroms über Coulomb-Wechselwirkung akkumulierter photogenerierter Minoritätsladungsträger (Elektronen) beruht. Es werden Sensitivitäten von S_I=0,13 A W-1 ermittelt. Durch eine verbesserte RTD-Quanteneffizienz aufgrund eines optimierten Dotierprofils der Absorptionsschicht lässt sich die Sensitivität auf S_I=2,71 A W-1 erhöhen, was einem Multiplikationsfaktor von in etwa M\≈8,6 entspricht. Gleichzeitig wird jedoch der RTD-Hebelfaktor verringert, sodass n_(RTD p2)=0,42⋅n_(RTD p1). Erstmalig wurde damit erfolgreich Gas-Absorptionsspektroskopie anhand von H2O-Dampf mittels MIR-RTD-Fotodetektor an drei beieinanderliegenden Absorptionslinien demonstriert.
The noninvasive magnetic resonance imaging technique allows for the investigation of functional processes in the living plant. For this purpose during this work, different NMR imaging methods were further developed and applied.
For the localisation of the intrusion of water into the germinating rape seed with the simultaneous depiction of the lipid-rich tissue via a 3D rendering, in Chap. 5 the technique of interleaved chemical selective acquisition of water and lipid was used in the germinating seed. The utilization of high-resolution MR images of germinated seeds enabled the localization of a predetermined water gap in the lipid-rich aleurone layer, which resides directly under the seed coat. The for a long time in biology prevalent discussion, whether such a gap exists or the seed soaks up the water from all sides, rather like a sponge, could hereby, at least for the rapeseed seed, be answered clearly. Furthermore, the segmentation and 3D visualization of the vascular tissue in the rapeseed seeds was enabled by the high-resolution datasets, a multiply branched structure preconstructed in the seed could be shown. The water is directed by the vascular tissue and thus awakens the seed gradually to life. This re-awakening could as well be tracked by means of invasive imaging via an oxygen sensor. In the re-awakened seeds, the lipid degradation starts, other than expected, not in the lipid-rich cotyledons but in the residual endosperm remaining from seed development and in the aleurone layer which previously protected the embryo. Within this layer, the degradation could be verified in the high-resolution MR datasets.
The method presented in Chap. 6 provides a further characteristic trait for phenotyping of seeds and lipid containing plants in general. The visualization of the compounds of fatty acids in plant seeds and fruits could be achieved by the distinct utilization of chemical shift-selective imaging techniques. Via the application of a CSI sequence the fatty acid compounds in an olive were localized in a 2D slice. In conjunction with an individually adjusted CHESS presaturation module Haa85 the high-resolution 3D visualization of saturated and unsaturated fatty acid compounds in different seeds was achieved. The ratio maps calculated from these datasets allow to draw conclusions from the developmental stage or the type of seed. Furthermore, it could be shown that the storage condition of two soybean seeds with different storage time durations lead to no degradation of the fatty acid content.
Additional structural information from inside of dry seeds are now accessible via MRI. In this work the imaging of cereal seeds could be significantly improved by the application of the UTE sequence. The hitherto existing depictions of the lipid distribution, acquired with the spin echo sequence, were always sufficient for examinations of the lipid content, yet defects in the starchy endosperm or differences in the starch concentration within the seed remained constantly unseen with this technique. In a direct comparison of the datasets acquired with the previous imaging technique (spin echo) and with UTE imaging, the advantage of data acquisition with UTE could be shown. By investigating the potential seed compounds (starch, proteins, sugar) in pure form, the constituent parts contributing to the signal could be identified as bound water (residual moisture) and starch. The application of a bi-exponential fit on the datasets of the barley seed enabled the separate mapping of magnetization and of relaxation time of two components contributing to the NMR signal. The direct comparison with histological stainings verified the previous results, thus this technique can be used for the selective imaging of starch in dry seeds.
Conclusions on the translocation characteristics in plants can be drawn by the technique proposed in Chap. 8. The associated translocation velocities can now, even in the range of several um/h, be determined in the living plant. Based on calculated concentrations of an MR contrast agent, which was taken up by the plant, these translocation velocities were estimated both in longitudinal direction, thus along the vascular bundle, and in horizontal direction, thus out of the bundle. The latter velocity is located below the contrast agent's velocity value of free diffusion. By adjusting a dynamic contrast-enhancing imaging technique (DCE-Imaging, Tof91) the acquisition duration of a T1-map was significantly reduced. By means of these maps, local concentrations of the contrast agent in plant stems and the siliques of the rapeseed plant could be determined.
Numerous questions in plant science can only be answered by non-invasive techniques such as MRI. For this reason, besides the experimental results achieved in this work, further NMR methods were tested and provided for the investigation of plants.
As an example, the study on the imaging of magnetic exchange processes are mentioned, which provided the groundwork for a possible transfer of CEST experiments (Chemical Exchange Saturation Transfer) to the plant. The results are presented in the bachelor thesis of A. Jäger Jae17, which was performed under my supervision, they find great interest under biologists.
The development of new technologies, which extend the possibilities for the investigation of living organisms, is of great importance. For this reason, I have contributed to the development of the currently unpublished method RACETE (Refocused Acquisition of Chemical Exchange Transferred Excitations [Jak17, Reu17, Gut18a]). By rephasing the transferred magnetization the utilization of properties which have not been available in chemical "`exchange"' experiments is enabled. With this method a positive contrast is generated, thus a reference experiment is not mandatory. Furthermore, the image phase, which in classical experiments contains no information about the exchanged protons, can be used for the distinct identification of multiple substances which have been excited simultaneously.
This recently at the Department of Experimental Physics V developed method can be used in particular for the identification of lipids and for the localization of sugars and amino acids, thus it can serve the enhancement and improvement of non-invasive analytical methods.
In dieser Arbeit werden Quantenpunkt-Speichertransistoren basierend auf modulationsdotierten GaAs/AlGaAs Heterostrukturen mit vorpositionierten InAs Quantenpunkten vorgestellt, welche in Abhängigkeit der Ladung auf den Quantenpunkten unterschiedliche Widerstände und Kapazitäten aufweisen. Diese Ladungsabhängigkeiten führen beim Anlegen von periodischen Spannungen zu charakteristischen, durch den Ursprung gehenden Hysteresen in der Strom-Spannungs- und der Ladungs-Spannungs-Kennlinie. Die ladungsabhängigen Widerstände und Kapazitäten ermöglichen die Realisierung von neuromorphen Operationen durch Nachahmung von synaptischen Funktionalitäten und arithmetischen Operationen durch Integration von Spannungs- und Lichtpulsen.
Transition metal oxides (TMO) represent a highly interesting material class as
they exhibit a variety of different emergent phenomena including multiferroicity and
superconductivity. These effects result from a significant interplay of charge, spin
and orbital degrees of freedom within the correlated d-electrons. Oxygen vacancies
(OV) at the surface of certain d0 TMO release free charge carriers and prompt the
formation of a two-dimensional electron gas (2DEG). Barium titanate (BaTiO3) is a
prototypical and promising d0 TMO. It displays ferroelectricity at room temperature
and features several structural phase transitions, from cubic over tetragonal (at
room temperature) and orthorhombic to rhombohedral. The spontaneous electric
polarization in BaTiO3 can be used to manipulate the physical properties of adjacent
materials, e.g. in thin films. Although the macroscopic properties of BaTiO3 are studied
in great detail, the microscopic electronic structure at the surface and interface of
BaTiO3 is not sufficiently understood yet due to the complex interplay of correlation
within the d states, oxygen vacancies at the surface, ferroelectricity in the bulk and
the structural phase transitions in BaTiO3.
This thesis investigates the electronic structure of different BaTiO3 systems by
means of angle-resolved photoelectron spectroscopy (ARPES). The valence band of
BaTiO3 single crystals is systematically characterized and compared to theoretical
band structure calculations. A finite p-d hybridization of titanium and oxygen states
was inferred at the high binding energy side of the valence band. In BaTiO3 thin films,
the occurrence of spectral weight near the Fermi level could be linked to a certain
amount of OV at the surface which effectively dopes the host system. By a systematic
study of the metallic surface states as a function of temperature and partial oxygen
pressure, a model was established which reflects the depletion and accumulation of
charge carriers at the surface of BaTiO3. An instability at T ~ 285K assumes a volatile
behavior of these surface states.
The ferroelectricity in BaTiO3 allows a control of the electronic structure at the interface
of BaTiO3-based heterostructures. Therefore, the interface electronic structure
of Bi/BaTiO3 was studied with respect to the strongly spin-orit coupled states in Bi by
also including a thickness dependent characterization. The ARPES results, indeed,
confirm the presence of Rashba spin-split electronic states in the bulk band gap of the ferroelectric substrate. By varying the film thickness in Bi/BaTiO3, it was able to modify
the energy position and the Fermi vector of the spin-split states. This observation
is associated with the appearance of an interface state which was observed for very
low film thickness. Both spectral findings suggest a significant coupling between the
Bi films and BaTiO3.
Neue Therapieansätze durch Tissue Engineering erfordern gleichzeitig angepasste Diagnosemöglichkeiten und nicht-invasive Erfolgskontrollen. Speziell die 3D-MR-Bildgebung ist ein vielversprechendes Instrument, um Parameter mit hoher räumlicher Präzision zu quantifizieren. Vor diesem Hintergrund wurden im Rahmen dieser Arbeit neue Ansätze für die hochauflösende 3D-MRT in vivo entwickelt und deren Eignung im Bereich des Tissue Engineerings gezeigt.
Welchen Vorteil die Quantifizierung von Parametern bietet, konnte im Rahmen einer prä-klinischen Studie an einem Modell der Hüftkopfnekrose gezeigt werden. Der Therapieverlauf wurde zu verschiedenen Zeitpunkten kontrolliert. Trotz der niedrigen räumlichen Auflösung, konnten durch eine systematische Auswertung der Signalintensitäten von T1- und T2-FS-gewichteten Aufnahmen Rückschlüsse über Veränderungen in der Mikrostruktur gezogen werden, die darüber hinaus in guter Übereinstimmung mit Ergebnissen von ex vivo µCT-Aufnahmen waren. Dort konnte eine Verdickung der Trabekelstruktur nachgewiesen werden, welche sehr gut mit einer Signalabnahme in den T1-gewichteten Aufnahmen korrelierte. Die radiale Auswertung der Daten erlaubte dabei eine komprimierte Darstellung der Ergebnisse. Dadurch wurde eine effiziente Auswertung der umfangreichen Daten (verschiedene Tiere an mehreren Zeitpunkten mit einer Vielzahl an Einzelaufnahmen) ermöglicht und eine unabhängige Bewertung erreicht.
Um die Limitationen der begrenzten Auflösung von 2D-Multi-Schichtaufnahmen aufzuheben, wurden neue Ansätze für eine hochaufgelöste 3D-Aufnahme entwickelt. Hierfür wurden Spin-Echo-basierte Sequenzen gewählt, da diese eine genauere Abbildung der Knochenmikrostruktur erlauben als Gradienten-Echo-basierte Methoden. Zum einen wurde eine eigene 3D-FLASE-Sequenz entwickelt und zum anderen eine modifizierte 3D-TSE-Sequenz. Damit an Patienten Aufnahmen bei klinischer Feldstärke von 1,5 T mit einer hohen räumlichen Auflösung innerhalb einer vertretbaren Zeit erzielt werden können, muss eine schnelle und signalstarke Sequenz verwendet werden. Eine theoretische Betrachtung bescheinigte der TSE-Sequenz eine um 25 % höhere Signaleffizienz verglichen mit einer FLASE-Sequenz mit identischer Messzeit. Dieser Unterschied konnte auch im Experiment nachgewiesen werden. Ein in vivo Vergleich der beiden Sequenzen am Schienbein zeigte eine vergleichbare Darstellung der Spongiosa mit einer Auflösung von 160 × 160 × 400 µm.
Für die Bildgebung des Hüftkopfs mit der neuen Sequenz waren jedoch aufgrund der unterschiedlichen Anatomie weitere Modifikationen notwendig. Um längere Messzeiten durch ein unnötig großes Field-of-View zu vermeiden, mussten Einfaltungsartefakte unterdrückt werden. Dies wurde durch die orthogonale Anwendung der Anregungs- und Refokussierungspulse in der TSE-Sequenz effizient gelöst. Technisch bedingt konnte jedoch nicht eine vergleichbare Auflösung wie am Schienbein realisiert werden.
Der Vorteil der 3D-Bildgebung, dass Schichtdicken von deutlich weniger als 1 mm erreicht werden können, konnte jedoch erfolgreich auf den Unterkiefer übertragen werden. Der dort verlaufende Nervus Mandibularis ist dabei eine wichtige Struktur, deren Verlauf im Vorfeld von verschiedenen operativen Eingriffen bekannt sein muss. Er ist durch eine dünne knöcherne Wand vom umgebenden Gewebe getrennt. Im Vergleich mit einer 3D-VIBE-Sequenz zeigte die entwickelte 3D-TSE-Sequenz mit integrierter Unterdrückung von Einfaltungsartefakten eine ähnlich gute Lokalisierung des Nervenkanals über die gesamte Länge der Struktur. Dies konnte in einer Studie an gesunden Probanden mit verschiedenen Beobachtern nachgewiesen werden. Durch die neue Aufnahmetechnik konnte darüber hinaus die Auflösung im Vergleich zu bisherigen Studien deutlich erhöht werden, was insgesamt eine präzisere Lokalisierung des Nervenkanals erlaubt.
Ein Baustein des Tissue Engineerings sind bio-resorbierbare Materialien, deren Abbau- und Einwachsverhalten noch untersucht werden muss, bevor diese für die klinische Anwendung zugelassen werden. Die durchgeführten in vitro µMR-Untersuchungen an Polymerscaffolds zeigten die reproduzierbare Quantifizierung der Porengröße und Wandstärke. Darüber hinaus wurde eine inhomogene Verteilung der Strukturparameter beobachtet. Die Ergebnisse waren in guter Übereinstimmung mit µCT-Aufnahmen als Goldstandard. Unterschiedliche Varianten der Scaffolds konnten identifiziert werden. Dabei bewies sich die MR-Bildgebung als zuverlässige Alternative.
Insgesamt zeigen die Ergebnisse dieser Arbeit, welche Vorteile und Anwendungsmöglichkeiten die 3D-MRT-Bildgebung bietet, und dass auch mit klinischer Feldstärke in vivo Voxelgrößen im Submillimeterbereich für alle Raumrichtungen erreichbar sind. Die erzielten Verbesserungen in der räumlichen Auflösung erhöhen die Genauigkeit der verschiedenen Anwendungen und ermöglichen eine bessere Identifikation von kleinen Abweichungen, was eine frühere und zuverlässigere Diagnose für Patienten verspricht.
Einfluss metallischer Nanostrukturen auf die optoelektronischen Eigenschaften organischer Halbleiter
(2018)
Opto-elektronische Bauelemente auf Basis organischer Moleküle haben in den letzten Jahren nicht nur in Nischenbereichen, wie der Kombination organischer Photovoltaik mit gebäudeintegrierten Konzepten, sondern vor allem auch in der Entwicklung von kommerziell verfügbaren OLED (organische lichtemittierende Dioden) Bauteilen, wie 4K TV-Geräten und Handy Displays, an Bedeutung gewonnen. Im Vergleich zu anorganischen Bauteilen weisen jedoch vor allem organische Solarzellen noch weitaus geringere Effizienzen auf, weswegen die Erforschung ihrer Funktionsweise und der Einflüsse der einzelnen Bestandteile auf mikroskopischer Ebene für die Weiterentwicklung und Verbesserung des Leistungspotentials dieser Technologie unabdingbar ist. \\
Um dies zu erreichen, wurde in dieser Arbeit die Wechselwirkung zwischen der lokalisierten Oberflächenplasmonenresonanz (LSPR) metallischer Nanopartikel mit den optischen Anregungen organischer Dünnschichten in dafür eigens präparierten opto-elektronischen Hybrid-Bauteilen aus kleinen Molekülen untersucht. Durch die Implementierung und Kopplung an solche plasmonischen Nanostrukturen kann die Absorption bzw. Emission durch das lokal um die Strukturen erhöhte elektrische Feld gezielt beeinflusst werden. Hierbei ist der spektrale Überlapp zwischen LSPR und den Absorptions- bzw. E\-missions\-spek\-tren der organischen Emitter entscheidend. In dieser Arbeit wurden durch Ausnutzen dieses Mechanismus sowohl die Absorption in organischen photovoltaischen Zellen erhöht, als auch eine verstärkte Emission in nanostrukturierten OLEDs erzeugt. \\
Besonderer Fokus wurde bei diesen Untersuchungen auf mikroskopische Effekte durch neu entstehende Grenzflächen und die sich verändernden Morphologien der aktiven organischen Schichten gelegt, da deren Einflüsse bei optischen Untersuchungen oftmals nur unzureichend berücksichtigt werden. In der Arbeit wurden daher die nicht zu vernachlässigenden Folgen der Einbringung von metallischen Nanostrukturen auf die Morphologie und Grenzflächen zusammen mit den spektralen Veränderungen der Absorptions- und Emissionscharakteristik organischer Moleküle analysiert und in Zusammenhang gebracht, wodurch eine Verbesserung der Effizienzen opto-elektronischer Bauteile erreicht werden soll.
Quantifizierung myokardialer Mikrostruktur und Perfusion mittels longitudinaler NMR Relaxation
(2018)
Ziel der Arbeit war es die Quantifizierung funktioneller bzw. mikrostruktureller Parameter des Herzmuskels mit Hilfe T1-basierter Methoden zu verbessern. Diese Methoden basieren darauf, die gewünschte Information durch eine geeignete Präparation der Magnetisierung bzw. durch die Gabe von Kontrastmittel in den Zeitverlauf der longitudinalen Relaxation zu kodieren. Aus der Änderung der Relaxationszeit läßt sich dann die gewünschte Information bestimmen. Dafür sollte sowohl der Einfluß der Anatomie als auch derjenige der Meßmethodik auf die Bestimmung der longitudinalen Relaxationszeit und damit auf die Quantifizierung der Funktion bzw. Mikrostrukturparameter untersucht werden.
Speziell der Einfluß der Bildgebungssequenz führt dazu, daß nur eine scheinbare Relaxationszeit gemessen wird. Während dies keinen Einfluß auf die T1-basierte Bestimmung der untersuchten Mikrostrukturparameter hatte, ergab sich für die Perfusionsquantifizierung eine deutliche Abhängigkeit von den Parametern der verwendeten IRLL-Sequenz. Um diesen Einfluß gerecht zu werden, wurden an die Meßmethodik angepaßte Gleichungen zur Bestimmung der Perfusion gefunden mit denen die systematischen Abweichungen korrigiert werden können. Zusätzlich reduzieren die angepaßten Gleichungen die Anforderungen bezüglich der Inversionsqualität im schichtselektiven Experiment. Dies wurde in einem weiteren Projekt bei der Bestimmung der Nierenperfusion im Mausmodell ausgenutzt.
Neben der Untersuchung der Auswirkungen der Meßmethode wurde auch der Einfluß der anatomischen Besonderheiten des Blutkreislaufs am Herzen auf die Parameterquantifizierung mittels T1-basierter Methoden untersucht. Es konnte gezeigt werden, daß auf Grund der Anatomie des Herzens bei typischen Orientierungen der Bildgebungsschicht, auch bei der schichtselektiven Inversionspräparation der Magnetisierung des Herzmuskels ein Anteil des Blutpools invertiert wird. Daraus folgt, daß die vereinfachende Annahme, nach welcher bei schichtselektiver Präparation in Folge von Perfusion nur Blut mit Gleichgewichtsmagnetisierung den Herzmuskel erreicht, nicht erfüllt ist. Es konnte gezeigt werden, daß dies bei Perfusion zu einer deutlichen Unterschätzung der berechneten Perfusionswertes führt. Um mit diesem Problem umgehen zu können, wurde aufbauend auf einem vereinfachten Modell der zeitlichen Entwicklung der Blutmagnetisierung eine Korrektur für die Bestimmung der Perfusionswerte gefunden welche den Einfluß der anatomischen Besonderheiten berücksichtigt.
Das für die Perfusionskorrektur eingeführte Model prognostiziert ebenso, daß auch bei schichtselektiver Inversion die T1-basierte Bestimmung der untersuchten Mikrostrukturparameter von der Perfusion abhängig wird und eine systematische Überschätzung der quantifizierten Werte verursacht. Da die Perfusion im Kleintier deutlich höher ist als im Menschen, ist dieser Einfluß besonders in der präklinischen Forschung zu beachten. So können dort allein durch verminderte Perfusion deutliche Änderungen in den bestimmten Werten der Mikrostrukturparameter erzeugt werden, welche zu einer fehlerhaften Interpretation der Ergebnisse führen und somit ein falsches Bild für die Vorgänge im Herzmuskel suggerieren. Dabei bestätigt der Vergleich mit experimentellen Ergebnissen aus der Literatur die Vorhersagen für das Rattenmodell. Beim Menschen ist der prognostizierte Effekt deutlich kleiner. Der prognostizierte Fehler bspw. im RBV-Wert liegt in diesem Fall bei etwa 10% und wird üblicherweise in der aktuellen Forschung vernachlässigt. Inwieweit dies in er klinischen Forschung gerechtfertigt ist, muß in weiteren Untersuchungen geklärt werden.
Den untersuchten Methoden zur Bestimmung von funktionellen und mikrostrukturellen Parametern ist gemein, daß sie eine exakte Quantifizierung der longitudinalen Relaxationszeit T1 benötigen. Dabei ist im Kleintierbereich die klassische IRLL-Methode als zuverlässige Sequenz zur T1-Quantifizierung etabliert. In der klinischen Bildgebung werden auf Grund der unterschiedlichen Zeitskalen und anderer technischer Voraussetzungen andere Anforderungen an die Datenakquisition gestellt. Dabei hat in den letzten Jahren die MOLLI-Sequenz große Verbreitung gefunden. Sie ist eine Abwandlung der IRLL-Sequenz, bei der mit einer bSSFP-Bildgebungssequenz getriggert ganze Bilder während eines Herzschlages aufgenommen werden. Die MOLLI-Sequenz reagiert dabei empfindlich auf die Wartezeiten zwischen den einzelnen Transienten. Um mit diese Problematik in den Griff zu bekommen und gleichzeitig die Meßzeit verkürzen zu können wurde eine neue Methode zum Fitten der Daten entwickelt, welche die Abhängigkeit der scheinbaren Relaxationszeit von der Wartezeit zwischen den einzelnen Transienten, sowie der mittleren Herzrate fast vollständig eliminiert. Diese Methode liefert für das ganze klinisch Spektrum an erwarteten T1-Zeiten, vor und nach Kontrastmittelgabe, stabile Ergebnisse und erlaubte ein deutliche Verkürzung der Meßzeit, ohne die Anzahl der aufgenommenen Meßzeitpunkte zu reduzieren. Dies wurde in einer initialen klinischen Studie genutzt, um ECV-Werte in Patienten zu bestimmen.
Ein Nachteil der Verwendung der MOLLI-Sequenz ist, daß nur die scheinbare Relaxationszeit aus den Fit der Meßdaten bestimmt wird. Die standardmäßig genutzte Korrektur benutzt aber dem gefitteten Wert der Gleichgewichtsmagnetisierung um den wahren T1-Wert zu bestimmen. Somit ist es für die Bestimmung des T1-Wertes notwendig, die Qualität der Inversionspräparation zu kennen. Auf Basis der neuen Fitmethode wurde eine Anpassung der MOLLI-Sequenz demonstriert, welche die Bestimmung der Gleichgewichtsmagnetisierung unabhängig von der Qualität der Inversionspräparation erlaubt. Dafür verlängert sich die Meßdauer lediglich um einen Herzschlag um in geeigneter Weise ein zusätzliches Bild aufnehmen zu können.
Abschließend wurde in dieser Arbeit der Signal-Zeit-Verlauf der MOLLI-Sequenz eingehend theoretische untersucht um ein besseres Verständnis der getriggerten IRLL-Sequenzen zu entwickeln. In diesem Zusammenhang konnte eine einfache Interpretation der scheinbaren Relaxationszeit gefunden werden. Ebenso konnte erklärt werden, warum die für ungetriggerte IRLL-Sequenzen abgeleitete Korrekturgleichung auch im getriggerten Fall erstaunlich gute Ergebnisse liefert. Weiterhin konnten Fehlerquellen für die verbleibenden Abweichungen identifiziert werden, welche als Ausgangspunkt für die Ableitung verbesserter Korrekturgleichungen genutzt werden können.
Als Orbitaltomographie wird eine junge Methode innerhalb der Photoelektronenspektrokopie bezeichnet, welche es ermöglicht, Molekülorbitale mit hoher Ortsauflösung abzubilden. Hierfür werden die zu untersuchenden Moleküle durch elektromagnetische Strahlung angeregt und die mittels Photoeffekt emittierten Elektronen hinsichtlich ihres Impulses und ihrer kinetischen Energie charakterisiert. Moderne Photoemissionsexperimente erlauben die simultane Vermessung des gesamten Impulshalbraumes oberhalb der Probe. Die detektierte Intensitätsverteilung stellt dann unter bestimmten Bedingungen das Betragsquadrat eines hemisphärischen Schnittes durch den Fourierraum des spektroskopierten Orbitals dar, wobei der Radius der Hemisphäre von der Energie der anregenden Strahlung abhängt.
Bei den in dieser Arbeit untersuchten Systemen handelt es sich um adsorbierte Moleküle, die hochgeordnete Schichten auf kristallinen Edelmetalloberflächen bilden. Im Fall eindomänigen Wachstums liefern die parallel orientierten Moleküle identische Photoemissionssignale. Kommt es hingegen zur Ausbildung von Rotations- und Spiegeldomänen, stellt die gemessene Impulsverteilung eine Superposition der unterschiedlichen Einzelbeiträge dar. Somit lassen sich Rückschlüsse auf die Orientierungen der Moleküle auf den Substraten ziehen. Diese Charakterisierung molekularer Adsorptionsgeometrien wird anhand verschiedener Modellsysteme vorgestellt.
Variiert man die Energie der anregenden Strahlung und somit den Radius der hemisphärischen Schnitte durch den Impulsraum, ist es möglich den Fourierraum des untersuchten Molekülorbitals dreidimensional abzubilden. Kombiniert man die gemessenen Intensitäten mit Informationen über die Phase der Wellenfunktion im Impulsraum, die durch zusätzliche Experimente oder rechnerisch gewonnen werden können, lässt sich durch eine Fouriertransformation ein dreidimensionales Bild des Orbitals generieren, wie Schritt für Schritt gezeigt wird.
Im Zuge eines Photoemissionsprozesses kann das Molekül in einen angeregten vibronischen Zustand übergehen. Mittels Photoemissionsexperimenten mit hoher Energieauflösung lassen sich Unterschiede zwischen den Impulsverteilungen der schwingenden Moleküle und denen im vibronischen Grundzustand feststellen. Ein Vergleich der Messdaten mit Simulationen kann die Identifikation der angeregten Schwingungsmode ermöglichen, was eine neue Methode darstellt, Erkenntnisse über die Elektron-Phonon-Kopplung in molekularen Materialien zu gewinnen.