Introduction: Since 1996, the preferred approach for positioning the active middle-ear implant Vibrant Soundbridge© is a mastoidectomy and a posterior tympanotomy. With this device, placement of the floating mass transducer (FMT) on the long incus process is the standard method for treatment of mild-to-severe sensorineural hearing loss in the case of normal middle-ear anatomy. The aim of this study was to determine the vibrational effectiveness of FMT placement at the short incus process. Materials and Methods: An extended antrotomy and a posterior tympanotomy were performed in 5 fresh human temporal bones. As a control for normal middle-ear function, the tympanic membrane was stimulated acoustically and the vibration of the stapes footplate and the round-window (RW) membrane were (sequentially) measured by laser Doppler vibrometry. Vibration responses for coupling of an FMT to the long incus process (standard coupling) were compared to those for coupling to the short incus process. Results: Apart from narrow frequency bands near 3 and 9 kHz for the stapes footplate and RW membrane, respectively, the velocity responses presented no significant differences between standard coupling of the FMT and coupling to the short incus process. Conclusion: Coupling the FMT to the short incus process may be a viable alternative in cases where the surgical approach is limited to an extended antrotomy. A reliable technique for attachment to the short incus process has yet to be developed.
Background
Fabry Disease (FD) is an X-linked hereditary lysosomal storage disorder which leads to a multisystemic intralysosomal accumulation of globotriaosylceramid (Gb3). Besides prominent renal and cardiac organ involvement, patients commonly complain about vestibulocochlear symptoms like high-frequency hearing loss, tinnitus and vertigo. However, comprehensive data especially on vertigo remain scarce. The aim of this study was to examine the prevalence and characteristics of vertigo and hearing loss in patients with FD, depending on renal and cardiac parameters and get hints about the site and the pattern of the lesions.
Methods
Single-center study with 57 FD patients. Every patient underwent an oto-rhino-laryngological examination as well as videonystagmography and vestibular evoked myogenic potentials (VEMPs) and audiological measurements using pure tone audiometry and auditory brainstem response audiometry (ABR). Renal function was measured by eGFR, cardiac impairment was graduated by NYHA class.
Results
More than one out of three patients (35.1%) complained about hearing loss, 54.4% about vertigo and 28.1% about both symptom. In 74% a sensorineural hearing loss of at least 25 dB was found, ABR could exclude any retrocochlear lesion. Caloric testing showed abnormal values in 71.9%, VEMPs were pathological in 68%. A correlation between the side or the shape of hearing loss and pathological vestibular testing could not be revealed.
Conclusions
Hearing loss and vertigo show a high prevalence in FD. While hearing loss seems due to a cochlear lesion, peripheral vestibular as well as central nervous pathologies cause vertigo. Thus, both the site of lesion and the pathophysiological patterns seem to differ.