Refine
Has Fulltext
- yes (90)
Is part of the Bibliography
- yes (90)
Year of publication
Document Type
- Journal article (89)
- Doctoral Thesis (1)
Language
- English (90) (remove)
Keywords
- radiotherapy (14)
- Medizin (8)
- DNA damage (6)
- prostate cancer (6)
- VMAT (4)
- quality assurance (4)
- toxicity (4)
- IGRT (3)
- IMRT (3)
- Radiosurgery (3)
- Strahlentherapie (3)
- breast cancer (3)
- glioblastoma multiforme (3)
- head and neck cancer (3)
- long-term outcome (3)
- lung cancer (3)
- radiosensitivity (3)
- rectal cancer (3)
- stereotactic irradiation (3)
- DNA repair (2)
- DNA-PK (2)
- Glioblastoma (2)
- Halcyon (2)
- IMAT (2)
- Image-guidance (2)
- MRI (2)
- NSCLC (2)
- NVP-BEZ235 (2)
- PTEN (2)
- Radiotherapy (2)
- Stereotactic body radiotherapy (2)
- adaptation (2)
- apoptosis (2)
- autophagy (2)
- cancer (2)
- cell cycle arrest (2)
- clinical trials (2)
- complementary alternative medicine (2)
- cone beam CT (2)
- depression (2)
- fatigue (2)
- histone H2AX (2)
- hypofractionation (2)
- hypoxia (2)
- irradiation (2)
- isocenter (2)
- megavoltage computed-tomography (2)
- migration (2)
- osteopontin (2)
- p53 (2)
- prostate-cancer (2)
- radiation sensitivity (2)
- radiotherapy (RT) (2)
- salvage radiotherapy (2)
- simultaneous integrated boost (2)
- spine radiosurgery (2)
- stereotactic body radiotherapy (2)
- survival (2)
- vertebral metastases (2)
- 2-step IMRT (1)
- 28 (1)
- 3D conformal silicone bolus (1)
- 3D printer (1)
- 4D-MRI (1)
- 68Ga-DOTATATE (1)
- ACR practice guidelines (1)
- ASCs (1)
- ATM (1)
- AZD6244 (1)
- Adaptation (1)
- Akt (1)
- Atherosclerotic plaque (1)
- Automated analysis (1)
- BRAF (1)
- Brain cancer (1)
- CD133 (1)
- CIED malfunction; pacemaker (PM) (1)
- CNS cancer (1)
- CRISPR-Cas9 (1)
- Cardiovascular risk factors (1)
- Cerebral small vessel disease (1)
- Combination (1)
- Cone-beam CT (1)
- Corticosteroids (1)
- Couch tracking (1)
- DNA double strand breaks (1)
- DNA double-strand breaks (1)
- DNA repair protraction (1)
- DNS-Reparatur (1)
- DNS-Schädigung (1)
- Dixon (1)
- E-cadherin (1)
- EBRT (1)
- EORTC-BN20 (1)
- EORTC-QLQ-C15-PAL (1)
- Enzyme Regulation (1)
- Extended field irradiation (1)
- Follicular lymphoma (1)
- Frame-based (1)
- Frame-less (1)
- Gimbaled tracking (1)
- Glioma stem cells (1)
- HECT Ligase (1)
- HUWE1 (1)
- Head and neck cancer (1)
- High grade glioma (1)
- Histone gamma H2AX (1)
- Hitzeschock-Proteine (1)
- Hitzeschockproteine (1)
- IR (1)
- ImageJ plugin (1)
- Improved survival (1)
- Inter-observer variability (1)
- Ionizing radiation (1)
- JUN (1)
- Krebsforschung (1)
- Locoregional recurrence (1)
- Lung cancer (1)
- MLC tracking (1)
- MYC (1)
- Macrophage (1)
- Mammakarzinom (1)
- Medicine (1)
- Meningioma (1)
- Molecular Biophysics (1)
- N-Myc down regulated gene 1 (1)
- NOTCH (1)
- Nampt (1)
- Nestin (1)
- Non-rigid image registration (1)
- Normal tissue tolerance (1)
- Novel PI3K (1)
- Open-source tool (1)
- Organ motion (1)
- Osteopontin (1)
- P14ARF (1)
- PBEF (1)
- PI3K (1)
- PRRT (1)
- PSMA (1)
- PSMA PET/CT (1)
- Pain (1)
- Palliativmedizin (1)
- Pelvic tumors (1)
- Peptide receptor radionuclide therapy (1)
- Peripheral blood lymphocytes (1)
- Phase II trial (1)
- Prostate carcinoma (1)
- Radiation biology (1)
- Radiation sensitivity (1)
- Radiosensitivity (1)
- Radiotherapy treatment planning (1)
- Re-irradiation (1)
- Rectal cancer (1)
- Respiration correlated imaging (1)
- Respiratory induced tumor motion (1)
- Robotic tracking (1)
- SHRSP (1)
- Short dsRNA oligonucleotides (1)
- Somatostatin receptor (1)
- Spinal metastases (1)
- Spinal metastasis (1)
- Step and Shoot IMRT (1)
- Stereotactic (1)
- Strahlenbiologie (1)
- Strahlenempfindlichkeit (1)
- Structural Biology (1)
- Symptomlinderung (1)
- Synergy (1)
- TGFβ1 (1)
- TME (1)
- Temozolomide (1)
- Total nodal irradiation (1)
- Tumorzelle (1)
- Tumorzellen (1)
- Ubiquitin (1)
- VIBE (1)
- VSOP (1)
- Winston‐Lutz test (1)
- X-Ray Chrystallography (1)
- Yoga (1)
- \(\gamma\)h2ax (1)
- accelerated hyperfractionation (1)
- acute toxicity (1)
- adaption (1)
- adaptive radiotherapy (1)
- adenocarcinoma (1)
- adipocytokines (1)
- adipose tissue-derived stromal cells (1)
- adrenal tumours (1)
- adrenocortical carcinoma (ACC) (1)
- advanced technology (1)
- altered fractionation (1)
- anxiety (1)
- auto-planning (1)
- battery depletion (1)
- beta-catenin (1)
- biochemical relapse free survival (1)
- blood lymphocytes (1)
- brain cancer (1)
- brain tumor (1)
- brain tumours (1)
- breath-hold (1)
- buildup region (1)
- cancer patients (1)
- capacitance (1)
- cardiac implantable electronic devices (CIED) (1)
- cardiac resynchronization therapy (CRT) (1)
- cell labeling (1)
- cell membranes (1)
- cell proliferation (1)
- cell velocimetry (1)
- chemoradiotherapy (1)
- chemotherapy (1)
- clinical application (1)
- colony survival (1)
- colorectal cancer (1)
- cone-beam ct (1)
- conformal radiotherapy (1)
- credentialing (1)
- cyberknife radiosurgery (1)
- cytoskeleton (1)
- dabrafenib (1)
- data acquisition (1)
- deformable image registration (1)
- delineation (1)
- density (1)
- depth dose curves (1)
- diode (1)
- dominant intraprostatic lesion (1)
- dose accumulation (1)
- dose escalation (1)
- dose evaluation (1)
- dose to OARs (1)
- dosimetry (1)
- double arc (1)
- dual-energy CT (1)
- dual-source CT (1)
- echinocytes (1)
- echo planar imaging (1)
- effective point of measurement (1)
- electrometer (1)
- electroporation (1)
- expression (1)
- external beam radiotherapy (EBRT) (1)
- flat silicone bolus (1)
- focal radiotherapy (1)
- foci (1)
- full arc (1)
- functional magnetic resonance imaging (1)
- fused deposition modeling (FDM) (1)
- gadoxetic acid (1)
- gamma H2AX-foci (1)
- gastric cancer (1)
- glioblastoma (1)
- guidance (1)
- head (1)
- head and neck squamous cell carcinoma (1)
- heat shock proteins (1)
- helical tomotherapy (1)
- hemoglobin jet (1)
- high-dose-rate (HDR) brachytherapy (1)
- high-dose-rate brachytherapy boost (1)
- histone γH2AX (1)
- hospital-based palliative care (1)
- human cancer diseases (1)
- hypotonic (1)
- illness-death model (1)
- image-guided radiation therapy (1)
- imaging techniques (1)
- implantable cardioverter defibrillator (ICD) (1)
- in vivo (1)
- individual case review (1)
- individual radiosensitivity (1)
- individual silicone bolus (1)
- inhibitor (1)
- intensity modulated radiotherapy (1)
- intensity-modulated radiation therapy (1)
- intensity-modulated radiotherapy (1)
- ionization chambers (1)
- iron oxide nanoparticles (1)
- irridation (1)
- isotonic (1)
- leaf width (1)
- limitations (1)
- liver metastases (1)
- liver oligometastases (1)
- long-term effects (1)
- lung metastases (1)
- mTOR (1)
- mTOR Inhibitor (1)
- macroscopic recurrence (1)
- matched filters (1)
- membrane characteristics (1)
- membrane proteins (1)
- meningioma (1)
- metastasis-directed therapy (1)
- methods (1)
- micro-chambers (1)
- micro-ionization chambers (1)
- microionization chambers (1)
- microvilli (1)
- mind-body intervention (1)
- mind–body intervention (1)
- modulated arc therapy (1)
- mouse model (1)
- multi-leaf collimator (1)
- multiple brain metastases (1)
- neck cancer (1)
- neoadjuvant (1)
- nicht-maligne Zellen (1)
- nicotinamide phosphoribosyltransferase (1)
- non-muscle myosin (1)
- non-small cell lung cancer (1)
- obesity (1)
- oligo-recurrence (1)
- oligometastases (1)
- oligorecurrence (1)
- online adaption (1)
- optimization (1)
- oral mucositis (1)
- outcome (1)
- outcomes research (1)
- overexpression (1)
- oxidative DNA damage (1)
- palliative care (1)
- palliative medicine (1)
- paraspinal tumors (1)
- partial arc (1)
- partitioning analysis RPA (1)
- patient-reported outcome (1)
- pediatric (1)
- penumbra (1)
- peptide receptor radionuclide therapy (PRRT) (1)
- percent depth dose curves (1)
- perioperative changes (1)
- peripheral blood lymphocytes (1)
- phlorizin (1)
- phosphorylation (1)
- plan comparison (1)
- planning study (1)
- planning variability (1)
- plans (1)
- polarity (1)
- prognostic index (1)
- prognostic value (1)
- propensity score matching (1)
- prostate Imaging Reporting and Data System (1)
- quaility indicator (1)
- quality of live (1)
- questionnaire (1)
- radiation (1)
- radiation biology (1)
- radiation dose (1)
- radiation oncology (1)
- radiation therapy (1)
- radiation-therapy (1)
- radiosensibility (1)
- radiosensitization (1)
- re-irradiation (1)
- re-planning (1)
- relative dosimetry (1)
- reminder e-mails (1)
- repair (1)
- risk (1)
- risk score (1)
- robotic table motion (1)
- scanning electron microscopy (1)
- scatter radiation (1)
- setup verification (1)
- signal filtering (1)
- signaling pathways (1)
- single arc (1)
- spectral CT (1)
- spine Radiosurgery (1)
- spine tumors (1)
- squamous cell carcinoma (1)
- standard (1)
- statistical data (1)
- stereotactic body radiation therapy (1)
- stereotactic radiotherapy (1)
- strategies (1)
- surface dose measurement (1)
- symptom control (1)
- symptoms (1)
- sync-oligometastases (1)
- temozolomide (1)
- therapy (1)
- tracking (1)
- transperineal ultrasound (1)
- transportome (1)
- treated metastases control (1)
- treatment (1)
- treatment plan (1)
- tumor biomarker (1)
- tumor cell lines (1)
- tumor control probability (1)
- validation (1)
- variability (1)
- vemurafenib (1)
- virtual isocenter (1)
- virtual isocentre (1)
- virtual non-contrast (1)
- visfatin (1)
- visfatin levels (1)
- volume regulation (1)
- volumetric modulated arc therapy (VMAT) (1)
- whole breast irradiation (1)
- whole-brain radiotherapy (1)
- wound healing (1)
- yoga (1)
- zinc oxide nanoparticles (1)
- ∆Np63 (1)
Institute
- Klinik und Poliklinik für Strahlentherapie (90) (remove)
Background: To analyze long-term results of radiotherapy alone for stage I-III low grade follicular lymphoma and to compare outcome after extended field irradiation (EFI) and total nodal irradiation (TNI). Methods and materials: Between 1982 and 2007, 107 patients were treated with radiotherapy alone for low grade follicular lymphoma at Ann Arbor stage I (n = 50), II (n = 36) and III (n = 21); 48 and 59 patients were treated with EFI and TNI, respectively. The median total dose in the first treatment series of the diaphragmatic side with larger lymphoma burden was 38 Gy (25 Gy – 50 Gy) and after an interval of median 30 days, a total dose of 28 Gy (12.6 Gy – 45 Gy) was given in the second treatment series completing TNI. Results: After a median follow-up of 14 years for living patients, 10-years and 15-years overall survival (OS) were 64% and 50%, respectively. Survival was not significantly different between stages I, II and III. TNI and EFI resulted in 15-years OS of 65% and 34% but patients treated with TNI were younger, had better performance status and higher stage of disease compared to patients treated with EFI. In multivariate analysis, only age at diagnosis (p<0.001, relative risk [RR] 1.06) and Karnofsky performance status (p = 0.04, RR = 0.96) were significantly correlated with OS. Freedom from progression (FFP) was 58% and 56% after 10-years and 15-years, respectively. Recurrences outside the irradiated volume were significantly reduced after TNI compared to EFI; however, increased rates of in-field recurrences and extra-nodal out-of-field recurrence counterbalanced this effect resulting in no significant difference in FFP between TNI and EFI. In univariate analysis, FFP was significantly improved in stage I compared to stage II but no differences were observed between stages I/II and stage III. In multivariate analysis no patient or treatment parameter was correlated with FFP. Acute toxicity was significantly increased after TNI compared to EFI with a trend to increased late toxicity as well. Conclusions: Radiotherapy alone for stage I and II follicular lymphoma resulted in long-term OS with high rates of disease control; no benefit of TNI over EFI was observed. For stage III follicular lymphoma, TNI achieved promising OS and FFP and should be considered as a potentially curative treatment option.
Background: To investigate geometric and dosimetric accuracy of frame-less image-guided radiosurgery (IG-RS) for brain metastases. Methods and materials: Single fraction IG-RS was practiced in 72 patients with 98 brain metastases. Patient positioning and immobilization used either double- (n = 71) or single-layer (n = 27) thermoplastic masks. Pre-treatment set-up errors (n = 98) were evaluated with cone-beam CT (CBCT) based image-guidance (IG) and were corrected in six degrees of freedom without an action level. CBCT imaging after treatment measured intra-fractional errors (n = 64). Pre- and posttreatment errors were simulated in the treatment planning system and target coverage and dose conformity were evaluated. Three scenarios of 0 mm, 1 mm and 2 mm GTV-to-PTV (gross tumor volume, planning target volume) safety margins (SM) were simulated. Results: Errors prior to IG were 3.9 mm± 1.7 mm (3D vector) and the maximum rotational error was 1.7° ± 0.8° on average. The post-treatment 3D error was 0.9 mm± 0.6 mm. No differences between double- and single-layer masks were observed. Intra-fractional errors were significantly correlated with the total treatment time with 0.7mm±0.5mm and 1.2mm±0.7mm for treatment times ≤23 minutes and >23 minutes (p<0.01), respectively. Simulation of RS without image-guidance reduced target coverage and conformity to 75% ± 19% and 60% ± 25% of planned values. Each 3D set-up error of 1 mm decreased target coverage and dose conformity by 6% and 10% on average, respectively, with a large inter-patient variability. Pre-treatment correction of translations only but not rotations did not affect target coverage and conformity. Post-treatment errors reduced target coverage by >5% in 14% of the patients. A 1 mm safety margin fully compensated intra-fractional patient motion. Conclusions: IG-RS with online correction of translational errors achieves high geometric and dosimetric accuracy. Intra-fractional errors decrease target coverage and conformity unless compensated with appropriate safety margins.
Age is one of the most salient aspects in faces and of fundamental cognitive and social relevance. Although face processing has been studied extensively, brain regions responsive to age have yet to be localized. Using evocative face morphs and fMRI, we segregate two areas extending beyond the previously established face-sensitive core network, centered on the inferior temporal sulci and angular gyri bilaterally, both of which process changes of facial age. By means of probabilistic tractography, we compare their patterns of functional activation and structural connectivity. The ventral portion of Wernicke’s understudied perpendicular association fasciculus is shown to interconnect the two areas, and activation within these clusters is related to the probability of fiber connectivity between them. In addition, post-hoc age-rating competence is found to be associated with high response magnitudes in the left angular gyrus. Our results provide the first evidence that facial age has a distinct representation pattern in the posterior human brain. We propose that particular face-sensitive nodes interact with additional object-unselective quantification modules to obtain individual estimates of facial age. This brain network processing the age of faces differs from the cortical areas that have previously been linked to less developmental but instantly changeable face aspects. Our probabilistic method of associating activations with connectivity patterns reveals an exemplary link that can be used to further study, assess and quantify structure-function relationships.
Background: External beam radiotherapy (EBRT) is the treatment of choice for irresectable meningioma. Due to the strong expression of somatostatin receptors, peptide receptor radionuclide therapy (PRRT) has been used in advanced cases. We assessed the feasibility and tolerability of a combination of both treatment modalities in advanced symptomatic meningioma. Methods: 10 patients with irresectable meningioma were treated with PRRT (177Lu-DOTA0,Tyr3 octreotate or - DOTA0,Tyr3 octreotide) followed by external beam radiotherapy (EBRT). EBRT performed after PRRT was continued over 5–6 weeks in IMRT technique (median dose: 53.0 Gy). All patients were assessed morphologically and by positron emission tomography (PET) before therapy and were restaged after 3–6 months. Side effects were evaluated according to CTCAE 4.0. Results: Median tumor dose achieved by PRRT was 7.2 Gy. During PRRT and EBRT, no side effects>CTCAE grade 2 were noted. All patients reported stabilization or improvement of tumor-associated symptoms, no morphologic tumor progression was observed in MR-imaging (median follow-up: 13.4 months). The median pre-therapeutic SUVmax in the meningiomas was 14.2 (range: 4.3–68.7). All patients with a second PET after combined PRRT + EBRT showed an increase in SUVmax (median: 37%; range: 15%–46%) to a median value of 23.7 (range: 8.0–119.0; 7 patients) while PET-estimated volume generally decreased to 81 ± 21% of the initial volume. Conclusions: The combination of PRRT and EBRT is feasible and well tolerated. This approach represents an attractive strategy for the treatment of recurring or progressive symptomatic meningioma, which should be further evaluated.
Background One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70 % of these patients. Conventional radiotherapy with of 1–10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3–6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology – intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery – have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1) A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2) Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions) or intermediate (5 fractions) life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3) Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. Methods / Design It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥2 points at the treated vertebral site on the 0 to 10 Visual Analogue Scale. 60 patients will be included into this two-centre phase II trial. Conclusions Results of this study will refine the methods of patient selection, target volume definition, treatment planning and delivery as well as quality assurance for radiosurgery. It is the intention of this study to form the basis for a future randomized controlled trial comparing conventional radiotherapy with fractionated radiosurgery for palliation of painful vertebral metastases. Trial registration ClinicalTrials.gov Identifier: NCT01594892
Background:
The vital importance of imaging techniques in radiation oncology now extends beyond diagnostic evaluation and treatment planning. Recent technical advances have enabled the integration of various imaging modalities into the everyday practice of radiotherapy directly at the linear accelerator, improving the management of inter-and intrafractional variations.
Methods:
We present the topic of image-guided radiotherapy (IGRT) on the basis of a selective review of the literature.
Results:
IGRT can be performed with the aid of ultrasound, 2D X-ray devices, and computed tomography. It enables instant correction for positioning deviations and thereby improves the precision of daily radiotherapy fractions. It also enables immediate adjustment for changes in the position and filling status of the internal organs. Anatomical changes that take place over the course of radiotherapy, such as weight loss, tumor shrinkage, and the opening of atelectases, can be detected as they occur and accounted for in dosimetric calculations. There have not yet been any randomized controlled trials showing that IGRT causes fewer adverse effects or improves tumor control compared to conventional radiotherapy.
Conclusion:
IGRT is more precise and thus potentially safer than conventional radiotherapy. It also enables the application of special radiotherapeutic techniques with narrow safety margins in the vicinity of radiosensitive organs. Proper patient selection for IGRT must take account of the goals of treatment and the planning characteristics, as well as the available technical and human resources. IGRT should be used for steep dose gradients near organs at risk, for highly conformal dose distributions in the gastrointestinal tract where adjustment for filling variations is needed, for high-precision dose escalation to avoid geographic miss, and for patients who cannot lie perfectly still because of pain or claustrophobia.
The majority of breast cancer patients will require radiation therapy at some time during the course of their disease. An estimated 30–50% of all radiation treatments are of palliative nature, either to alleviate symptoms or prophylactic to prevent deterioration of quality of life due to locally progressive disease. Radiotherapy is a locally effective tool, and typically causes no systemic and mostly mild acute side effects. The following article provides an overview of options and decision-making in palliative radiotherapy for symptom control.
Purpose
The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, thereby reducing the delivery time. The aim was to find classes of such solutions whose plan quality can compete with conventional IMRT.
Materials/Methods
A planning study was performed. Step and shoot IMRT plans were created using direct machine parameter optimization (DMPO) as a reference. DMPO plans were compared to an IMRT variant having only one segment per angle ("2-Step Fast"). 2-Step Fast is based on a geometrical analysis of the topology of the planning target volume (PTV) and the organs at risk (OAR). A prostate/rectum case, spine metastasis/spinal cord, breast/lung and an artificial PTV/OAR combination of the ESTRO-Quasimodo phantom were used for the study. The composite objective value (COV), a quality score, and plan delivery time were compared. The delivery time for the DMPO reference plan and the 2-Step Fast IMRT technique was measured and calculated for two different linacs, a twelve year old Siemens Primus™ ("old" linac) and two Elekta Synergy™ "S" linacs ("new" linacs).
Results
2-Step Fast had comparable or better quality than the reference DMPO plan. The number of segments was smaller than for the reference plan, the number of gantry angles was between 23 and 34. For the modern linac the delivery time was always smaller than that for the reference plan. The calculated (measured) values showed a mean delivery time reduction of 21% (21%) for the new linac, and of 7% (3%) for the old linac compared to the respective DMPO reference plans. For the old linac, the data handling time per beam was the limiting factor for the treatment time reduction.
Conclusions
2-Step Fast plans are suited to reduce the delivery time, especially if the data handling time per beam is short. The plan quality can be retained or even increased for fewer segments provided more gantry angles are used.
Background
Spinal radiosurgery is a quickly evolving technique in the radiotherapy and neurosurgical communities. However, the methods of spine radiosurgery have not been standardized. This article describes the results of a survey about the methods of spine radiosurgery at five international institutions.
Methods
All institutions are members of the Elekta Spine Radiosurgery Research Consortium and have a dedicated research and clinical focus on image-guided radiosurgery. The questionnaire consisted of 75 items covering all major steps of spine radiosurgery.
Results
Strong agreement in the methods of spine radiosurgery was observed. In particular, similarities were observed with safety and quality assurance playing an important role in the methods of all institutions, cooperation between neurosurgeons and radiation oncologists in case selection, dedicated imaging for target- and organ-at-risk delineation, application of proper safety margins for the target volume and organs-at-risk, conformal planning and precise image-guided treatment delivery, and close clinical and radiological follow-up. In contrast, three major areas of uncertainty and disagreement were identified: 1) Indications and contra-indications for spine radiosurgery; 2) treatment dose and fractionation and 3) tolerance dose of the spinal cord.
Conclusions
Results of this study reflect the current practice of spine radiosurgery in large academic centers. Despite close agreement was observed in many steps of spine radiosurgery, further research in form of retrospective and especially prospective studies is required to refine the details of spinal radiosurgery in terms of safety and efficacy.
Background: To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods: An infrared(IR)-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP) and connected to the table via a 6 degree-of-freedom(DoF) mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT) is performed. A robotic 6 DoF treatment couch (HexaPOD™) then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results: Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD) of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102) was 1.6 ± 0.8 mm while intra-fraction movement (n = 110) was 0.6 ± 0.4 mm. Conclusions: This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intrafraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient comfort.