Funktionelle Bildgebung der Lunge und des Bronchialkarzinoms mittels Magnetresonanztomographie
(2008)
Ziel dieser Arbeit war es, die Magnetresonanztomographie (MRT) an der Lunge als Alternative zur traditionellen Lungenbildgebung voranzutreiben. So sollten MRT-Verfahren zur regionalen und quantitativen Lungenfunktionsprüfung für die klinische Routine entwickelt werden. Im Hinblick auf die Strahlentherapie von Patienten mit Bronchialkarzinom sollen funktionelle Lungenareale erkannt werden, um diese während der Bestrahlung optimal schonen zu können. An den zahlreichen Luft-Gewebe-Grenzflächen in der Lunge entstehen Magnetfeldinhomogenitäten. Daraus resultiert ein schneller Zerfall des MRT-Signals in der Lunge. Es wurde in dieser Arbeit ein Ansatz aufgezeigt, um die Ursache für den raschen Signalzerfall, nämlich die unterschiedlichen magnetischen Suszeptibilitäten von Lufträumen und Lungengewebe, zu beseitigen. Durch die intravaskuläre Injektion von paramagnetischen Kontrastmitteln kann die Suszeptibilität des Blutes an die Suszeptibilität der Lufträume angeglichen werden. Durch die Entwicklung einer MR-kompatiblen aktiven Atemkontrolle (MR-ABC) wurde in dieser Arbeit ein weiteres fundamentales Problem der Lungen-MRT adressiert: Die Bewegung während der Datenakquisition. Die MR-ABC detektiert Herzschlag und Atemposition und ist in der Lage die Atembewegung in jeder beliebigen Atemphase reproduzierbar für eine definierte Zeit auszusetzen. Dies wird durch einen Verschluss der Atemluftzufuhr realisiert. Traditionelle Verfahren können zwar ebenfalls die Atemphase detektieren, gestatten jedoch nicht deren Konservierung. Es wurde demonstriert, dass mit der MR-ABC hochauflösende Bilder der Lunge in hoher Bildqualität und durch die Verwendung langer Akquisitionsfenster in relativ kurzer Messzeit erreicht werden können. Eine regionale Lungenfunktionsprüfung ist für die Diagnose und Evaluierung vieler Krankheitsbilder vorteilhaft. In diesem Sinne wird seit einigen Jahren das Potential der Sauerstoff-verstärkten Lungen-MRT erforscht, die auf den paramagnetischen Eigenschaften des molekularen Sauerstoffs basiert. Im Blut gelöster Sauerstoff führt zu einer Verkürzung der T1-Relaxationszeit. Statt diese T1-Verkürzung quantitativ zu bestimmen wird aus praktischen Gründen meist ein T1-gewichteter Ansatz gewählt. In dieser Arbeit wurde jedoch gezeigt, dass nicht-quantitative Verfahren ein erhebliches Risiko zur Falschinterpretation beinhalten. Um Fehldiagnosen zu vermeiden, sollten deshalb prinzipiell quantitative Methoden zur Messung der durch die Sauerstoff-Verstärkung bedingten T1-Verkürzung in der Lunge verwendet werden. Herkömmliche Techniken zur quantitativen T1-Messung benötigen allerdings längere Messzeiten. Deshalb war zur Vermeidung von Bewegungsartefakten bisher die Datenaufnahme im Atemanhaltezustand notwendig. Wiederholtes Atemanhalten von mehreren Sekunden Dauer ist allerdings für einige Patienten sehr belastend. Aus diesem Grund wurden in dieser Arbeit zwei Methoden entwickelt, die eine quantitative Lungenfunktionsprüfung mittels MRT bei freier Atmung der Patienten ermöglichen. Eine gute Sauerstoffversorgung des Tumors wirkt sich positiv auf den Erfolg der Bestrahlung aus. Ein Ansatz zur Verbesserung der Strahlentherapie des Bronchialkarzinoms könnte daher in der Beatmung der Patienten mit hyperoxischen hypercapnischen Atemgasen während der Bestrahlung bestehen. In diesem Zusammenhang könnte die quantitative Messung der T1-Veränderung im Tumor nach Carbogenatmung ein Selektionskriterium darstellen, um diejenigen Patienten zu identifizieren, die von einer Carbogenbeatmung während der Bestrahlung profitieren können. Die Differenzierung zwischen vitalem Tumorgewebe, Nekrosen und atelektatischem Lungengewebe ist von großer Bedeutung bei der Bestrahlungsplanung des Bronchialkarzinoms. Einen neuen Ansatz bildet die in dieser Arbeit vorgestellte Magnetiserungstransfer-MRT. Um einen Magnetisierungstransfer zu erzeugen, wurde ein speziell auf die Bildgebung an der Lunge optimiertes Präparationsmodul entworfen. In Verbindung mit einer schnellen Bildakquisitionstechnik konnte die Magnetisierungstransfer-Lungenbildgebung in einem kurzen Atemstopp durchgeführt werden. Diese Technik wurde an mehreren Patienten mit Bronchialkarzinom evaluiert und die Ergebnisse mit denen der Fluor-Deoxyglykose-Positronen-Emissions-Tomographie (FDG-PET) verglichen. Es wurde festgestellt, dass mit diesem MRT-Verfahren ähnliche diagnostische Erkenntnisse erzielt werden können. Allerdings besitzt die MRT Vorteile im Hinblick auf räumliche Auflösung, Messzeit, Bildqualität, Kosten und Strahlenbelastung. Das erhebliche Potential für die Bestrahlungsplanung des Bronchialkarzinoms durch eine Magnetisierungstransfer-Bildgebung wurde damit nachgewiesen.
Das Ziel dieser Arbeit war die Evaluierung von morphologischen und funktionellen Techniken zur Untersuchung der Lunge am Niederfeld MRT bei Patienten mit Mukoviszidose. Patienten mit Mukoviszidose und lungengesunde Probanden wurden an einem Niederfeld-MRT (0,2 Tesla) mittels coronaren TrueFISP, FLASH 2D und FLASH 3D Sequenzen untersucht. T1 und T2*-Messungen wurden während Atmung von Raumluft und Atmung von 100 % Sauerstoff durchgeführt und die Parameterkarten pixelweise berechnet. Die für die Lungenbildgebung am Niederfeld-MRT optimierten 2D und 3D FLASH Sequenzen zeigten ein signifikant besseres Signalverhalten als die Standardsequenz TrueFISP. Zur Beurteilung der Parenchymveränderungen wurde ein MR-Score in Anlehnung an den Chrispin-Norman-Score angewandt. Es zeigte sich eine gute Korrelation zwischen dem MR-Score der FLASH-Sequenzen und dem etablierten CN-Score der konventionellen Bildgebung mit einer geringen Interobservariabiliät für die 2D und 3D FLASH Sequenzen. Schließlich konnte eine O2-gestütze funktionelle Bildgebung der Lunge bei Patienten mit Mukoviszidose am offenen Niederfeld-MRT etabliert werden. Es zeigten sich gute Korrelationen zwischen der relativen Änderung der T1 Relaxationszeit und der spirometrisch bestimmten Lungenfunktion. Ein solcher Zusammenhang konnte für die T2*-Messungen nicht hergestellt werden. Aufgrund der Patientenfreundlichkeit ist diese Technik insbesondere für die Untersuchung von Kindern geeignet.
In der vorliegenden Arbeit wird die Rotated-Cone-UTE-Sequenz (RC-UTE), eine 3D k-Raum-Auslesetechnik mit homogener Verteilung der Abtastdichte, vorgestellt. Diese 3D MR-Messtechnik ermöglicht die für die Detektion von schnell abfallenden Signalen notwendigen kurzen Echozeiten und weist eine höhere SNR-Effizienz als konventionelle radiale Pulssequenzen auf. Die Abtastdichte ist dabei in radialer und azimutaler Richtung angepasst. Simulationen und Messungen in vivo zeigen, dass die radiale Anpassung das T2-Blurring reduziert und die SNR-Effizienz erhöht. Die Drehung der Trajektorie in azimutale Richtung ermöglicht die Reduzierung der Unterabtastung bei gleicher Messzeit bzw. eine Reduzierung der Messzeit ohne Auflösungsverlust.
Die RC-UTE-Sequenz wurde erfolgreich für die Bildgebung des Signals des kortikalen Knochens und der Lunge in vivo angewendet. Im Vergleich mit der grundlegenden UTE-Sequenz wurden die Vorteile von RC-UTE in allen Anwendungsbeispielen aufgezeigt. Die transversalen Relaxationszeit T2* des kortikalen Knochen bei einer Feldstärke von 3.0T und der Lunge bei 1.5T und 3.0T wurde in 3D isotroper Auflösung gemessen. Außerdem wurde die Kombination von RC-UTE-Sequenz mit Methoden der Magnetisierungspräparation zur besseren Kontrasterzeugung gezeigt. Dabei wurden die Doppel-Echo-Methode, die Unterdrückung von Komponenten mit langer Relaxationszeit T2 durch Inversionspulse und der Magnetisierungstransfer-Kontrast angewendet.
Die Verwendung der RC-UTE-Sequenz für die 3D funktionelle Lungenbildgebung wird ebenfalls vorgestellt. Mit dem Ziel der umfassenden Charakterisierung der Lungenfunktion in 3D wurde die simultane Messung T1-gewichteter Bilder und quantitativer T2*-Karten für verschiedene Atemzustände an sechs Probanden durchgeführt. Mit der hier vorgestellten Methode kann die Lungenfunktion in 3D über T1-Wichtung, quantitative T2*-Messung und Rekonstruktion verschiedener Atemzustände durch Darstellung von Ventilation, Sauerstofftransport und Volumenänderung beurteilt werden.
The focus of the work concerned the development of a series of MRI techniques that were specifically designed and optimized to obtain quantitative and spatially resolved information about characteristic parameters of the lung. Three image acquisition techniques were developed. Each of them allows to quantify a different parameter of relevant diagnostic interest for the lung, as further described below:
1) The blood volume fraction, which represents the amount of lung water in the intravascular compartment expressed as a fraction of the total lung water. This parameter is related to lung perfusion.
2) The magnetization relaxation time T\(_2\) und T*\(_2\)
, which represents the component of T\(_2\) associated with the diffusion of water molecules through the internal magnetic field gradients of the lung. Because the amplitude of these internal gradients is related to the alveolar size, T\(_2\) und T*\(_2\) can be used to obtain information about the microstructure of the lung.
3) The broadening of the NMR spectral line of the lung. This parameter depends on lung inflation and on the concentration of oxygen in the alveoli. For this reason, the spectral line broadening can be regarded as a fingerprint for lung inflation; furthermore, in combination with oxygen enhancement, it provides a measure for lung ventilation.
Die idiopathische Lungenfibrose (IPF) stellt eine chronische Krankheit mit einer schlechten Prognose dar. Die Erkrankung zeichnet sich durch ein dysfunktionales Alveolarepithel, die Formation von α-smooth muscle actin (α-SMA)-positiven Myofibroblasten, eine starke Kollagendeposition sowie eine fehlgeleitete Inflammation aus. In der Vermittlung dieser pro-fibrotischen Effekte spielt das Zytokin transforming growth factor β (TGF-β) eine Schlüsselrolle. Aufgrund des tödlichen Verlaufs der IPF und der limitierten Therapieoptionen ist die Entdeckung neuer Behandlungsansätze erforderlich.
Der NO/cGMP-Signalweg ist in der Modulation grundlegender physiologischer Vorgänge wie der Blutdruckregulation und der Peristaltik involviert. Hierbei spielt die NO-sensitive Guanylyl-Cyclase (NO-GC) als NO-Rezeptor eine fundamentale Rolle. In der Lunge wird die NO-GC in glatten Muskelzellen und Perizyten exprimiert. Während das Enzym in glatten Muskelzellen die Relaxation der glatten Muskulatur vermittelt, reguliert die NO-GC in Perizyten die Angiogenese, die Kapillardurchlässigkeit und den Blutfluss. Neben den physiologischen Aufgaben wurden anti-fibrotische sowie anti-inflammatorische Effekte der NO-GC in Herz, Leber, Niere und Haut beschrieben.
Daher wurde im Rahmen dieser Arbeit die NO-GC auf eine anti-fibrotische und anti-inflammatorische Bedeutung in der Lungenfibrose der Maus überprüft. Hierzu wurden Wildtyp- (WT) und globale NO-GC-Knockout-Mäuse (GCKO) untersucht. Die Fibrose wurde durch einmalige, orotracheale Bleomycin-Gabe induziert und zu unterschiedlichen Zeitpunkten (Tag 7 und 21) untersucht. Unbehandelte (Tag 0) Tiere dienten als Kontrolle. Im ersten Teil dieser Arbeit wurde die NO-GC auf eine anti-fibrotische Wirkung untersucht. Mittels Immunfluoreszenz wurde das Verhalten der α-SMA-positiven Myofibroblasten in den platelet-derived growth factor receptor β (PDGFRβ)-positiven fibrotischen Regionen untersucht. Der Kollagengehalt wurde mithilfe eines Hydroxyprolin-Kollagenassays ermittelt. Die untersuchten Fibrose-Kriterien waren in beiden Genotypen an Tag 21 stärker ausgeprägt als an Tag 7. An Tag 21 konnten im GCKO mehr α-SMA-positive Myofibroblasten, ausgeprägtere PDGFRβ-positive fibrotische Areale und ein höherer Kollagengehalt als im WT festgestellt werden. Zudem zeigten die GCKO-Tiere ein schlechteres Überleben als WT-Mäuse. Diese Ergebnisse wiesen auf eine überschießende fibrotische Antwort im GCKO und somit auf eine anti-fibrotische Wirkung der NO-GC in der Bleomycin-induzierten Lungenfibrose hin. Dass an Tag 21 die Fibrose im GCKO stärker ausfiel als im WT, konnte mit dem signifikant höheren TGF-β-Gehalt in der bronchoalveolären Lavageflüssigkeit (BALF) im GCKO erklärt werden. Das Fehlen der NO-GC im GCKO könnte zu einem Wegfall der Inhibierung der TGF-β-vermittelten, pro-fibrotischen Effekte durch die NO-GC führen. Weitere Studien sind erforderlich, um die Hypothese zu belegen und zugrundeliegende Mechanismen aufzuklären.
Die de novo Entstehung von Myofibroblasten, die maßgeblich an der Kollagensynthese beteiligt sind, stellt ein entscheidendes Fibrose-Merkmal dar. Umso bedeutender ist die Identifikation zweier Myofibroblasten-Subtypen, die sich in Lokalisation, NO-GC-Expression und Herkunft unterscheiden: (1) interstitielle, NO-GC-positive Myofibroblasten, die von Perizyten abstammen und Kollagen Typ I produzieren, und (2) intra-alveoläre, NO-GC-negative Myofibroblasten, deren Ursprung noch nicht abschließend geklärt ist. Die Anwesenheit beider Myofibroblasten-Typen konnte zu beiden untersuchten Zeitpunkten nach Bleomycin-Gabe bestätigt werden. Die NO-GC-Expression der Alveolarwand-ständigen Myofibroblasten, deren Abstammung von NO-GC-positiven Perizyten sowie deren dauerhafte Präsenz sprechen für eine relevante Rolle der NO-GC in der murinen Lungenfibrose. In weiteren Untersuchungen müssen die exakten Funktionen und spezifische Marker der Myofibroblasten-Subtypen identifiziert werden.
Im zweiten Teil dieser Arbeit wurde die NO-GC auf anti-inflammatorische Effekte in der Bleomycin-induzierten Lungenfibrose untersucht. Mittels HE-Färbung und Immunfluoreszenz wurden lymphozytäre Infiltrate an Tag 21 im GCKO festgestellt, was auf einen modulatorischen Einfluss der NO-GC auf das Immunsystem hindeutete. An Tag 21 wurden in der BALF von GCKO-Tieren signifikant mehr Gesamtimmunzellen, Lymphozyten und neutrophile Granulozyten als im WT gezählt, was auf eine starke Einwanderung von Immunzellen und somit auf eine ausgeprägte Entzündung in GCKO-Lungen hinwies. Folglich könnte die NO-GC eine anti-inflammatorische Rolle über die Regulation der Immigration von Immunzellen in der Bleomycin-induzierten Lungenfibrose spielen. In der Literatur werden pro- und anti-fibrotische Effekte der Immunzellen in der murinen Lungenfibrose diskutiert. Durch Korrelationsanalysen wurde ein positiver Zusammenhang zwischen der Gesamtimmunzellzahl und der TGF-β-Konzentration an Tag 21 festgestellt. In verschiedenen Studien wurde ein pro-fibrotischer Einfluss der Immunzellen über die Aktivierung/Sekretion von TGF-β beschrieben. Die Abwesenheit der NO-GC im GCKO könnte also über die verstärkte Immigration von Immunzellen in einem erhöhten TGF-β-Gehalt resultieren und so zu einer überschießenden fibrotischen Reaktion an Tag 21 führen. Auf welche Weise die NO-GC die Einwanderung der Immunzellen in der Bleomycin-induzierten Lungenfibrose beeinflusst, muss in weiteren Studien untersucht werden. Zusammenfassend deuten die Daten dieser Arbeit auf eine anti-inflammatorische und anti-fibrotische Rolle der NO-GC in der Lungenfibrose der Maus hin.
Die humane Lunge kann bei der Pharmakotherapie einer Erkrankung entweder als betroffenes Organ Ziel eines verabreichten Arzneistoffes sein oder aber auch als Portal für diesen in die systemische Zirkulation fungieren. Wird ein Arzneistoff inhaliert, ist für dessen Nutzen-Risiko-Profil von zentraler Bedeutung, in welchem Ausmaß und mit welcher Geschwindigkeit dieser resorbiert und anschließend in die systemische Zirkulation umverteilt wird. Wenn bei der Behandlung einer Lungenerkrankung dagegen ein Arzneistoff z.B. nach peroraler Gabe erst in der systemischen Zirkulation anflutet, müssen ausreichend hohe Wirkstoffkonzentrationen in den betroffenen Gewebearealen sichergestellt werden. Ziel der vorliegenden Arbeit war es daher, Möglichkeiten zu finden, diese beiden Vorgänge in vitro möglichst realitätsnah messen zu können. Für die Simulation der pulmonalen Absorption nach inhalativer Applikation eines Arzneistoffs diente Beclomethasondipropionat (BDP), freigesetzt aus den handelsüblichen FCKW-freien Dosieraerosolen Sanasthmax® und Ventolair®, als Modellsubstanz. Es wurde zunächst ein einfaches Dialysemodell als Screeningverfahren entwickelt. Hier wurden BDP-Partikel unter Verwendung der beiden Dosieraerosole auf humanem Lungenhomogenat deponiert und nachfolgend die kombinierten Prozesse aus Auflösung und Umverteilung der Substanz in eine Dialyseflüssigkeit, die sich entweder aus salinem Puffer oder humanem Blutplasma zusammensetzte, untersucht. Anschließend wurde erstmals ein etabliertes humanes Lungenperfusionsmodell dahingehend modifiziert, dass eine Inhalation von BDP nach Applikation eines handelsüblichen Dosieraerosols nachgestellt werden konnte. Auf diese Weise konnte an diesem realitätsnahen Modell die initiale Phase der pulmonalen Absorption von BDP in der Perfusionsflüssigkeit verfolgt werden. Beide Modelle zeigten Unterschiede in der Auflösungs- bzw. Umverteilungskinetik von BDP in Abhängigkeit von der verwendeten Applikationsform auf. So schienen sich von Ventolair® erzeugte BDP-Partikel schneller und in größerer Menge aufzulösen als diejenige bei den Versuchen mit Sanasthmax®, was eine vermehrte Umverteilung der Substanz sowohl in die Dialyseflüssigkeit als auch Perfusionslösung zur Folge hatte. Die am Lungenperfusionsmodell beobachteten Verläufe der initialen pulmonalen Absorption von BDP nach Freisetzung aus den Dosieraerosolen Sanasthmax® oder Ventolair® korrelierten dabei sehr gut mit Daten aus einer entsprechenden Humanstudie mit gesunden Probanden. Auch standen die ermittelten Unterschiede in sinnvoller Übereinstimmung mit Untersuchungen der in den von Sanasthmax® oder Ventolair® versprühten Aerosolen enthaltenen Partikel hinsichtlich Größenverteilung, Morphologie und Lösungsverhalten in Bronchialsekret. Um die Umverteilung eines Wirkstoffs von der systemischen Zirkulation in lungenspezifisches Gewebe am humanen Lungenperfusionsmodell zu simulieren, wurden die Gewebekonzentrationen von Thalidomid (THAL) in peripherem Lungengewebe im Vergleich zu den korrespondierenden Spiegeln in einem Bronchialkarzinom erstmals mittels Mikrodialyse verfolgt. Hierzu wurde im Vorfeld für diese Substanz unter Einsatz des Komplexbildners (2 Hydroxypropyl)-beta-cyclodextrin (HPCD) ein bezüglich der Sensitivität und der zeitlichen Auflösung optimiertes Mikrodialysesystem etabliert und dessen Eigenschaften systematisch untersucht. Am Lungenperfusionsmodell wurde dann eine an klinisch relevante Plasmaspiegel angelehnte THAL-Konzentration in der Perfusionslösung vorgelegt und anschließend das Anfluten in den oben genannten Geweben mit Hilfe des entwickelten Mikrodialysesystems beobachtet. Durch Zugabe von HPCD in das Mikrodialyseperfusat konnte eine signifikante Erhöhung der Wiederfindungsrate im Dialysat (Relative Recovery) erreicht und damit ein Mikrodialysesystem etabliert werden, das neben hoher zeitlicher Auflösung eine ausreichende analytische Sensitivität für THAL aufwies. Allerdings wurden aufgrund dieses Perfusatzusatzes die Diffusionsvorgänge während der Mikrodialyse derart beeinflusst, dass übliche Methoden zur Sondenkalibrierung wie z.B. die Retrodialyse nicht mehr angewendet werden konnten, und daher in Hinblick auf die Messungen am Lungenperfusionsmodell bestehende Kalibrierverfahren modifiziert werden mussten. Bei der Untersuchung der Gewebepenetration am Lungenperfusionsmodell flutete THAL in Tumorgewebe langsamer an als in peripherem Lungengewebe, wo schnell ähnliche Konzentrationen wie in der Perfusionslösung gefunden wurden. Auch lagen die Gewebespiegel im Tumorgewebe stets unter dem ermittelten Niveau im Lungengewebe. Die erhaltenen Konzentrationsverhältnisse zwischen Perfusionslösung, peripherem Lungengewebe und Tumorgewebe deckten sich dabei mit Kenntnissen aus Humanstudien, in denen analog Plasmakonzentrationen von antineoplastischen Substanzen ebenfalls mittels Mikrodialyse in Relation zu deren Spiegeln in gesundem Gewebe und Tumorgewebe verschiedenster Ätiologie bestimmt wurden.
Patienten mit chronischen Lungenerkrankungen leiden unter schwerwiegender Symptomatik und bedürfen regelmäßiger Verlaufskontrollen der Therapie. Dabei sollte zum Schutz der Patienten sowohl auf kanzerogene, ionisierende Strahlung verzichtet als auch der Einsatz potenziell nebenwirkungsreicher Kontrastmittel vermieden werden. Die pulmonale Blutflussgeschwindigkeit im Parenchym stellt einen quantitativen, bildgebenden Biomarker dar, mit dessen Hilfe die Dynamik des Krankheitsgeschehens untersucht werden kann. In dieser Arbeit wurde eine neue Auswertungsmethode vorgestellt, die mit Hilfe kontrastmittelfreier Magnetresonanztomographie die Blutflussgeschwindigkeit im Lungenparenchym quantifizieren kann. Die auf diese Weise bestimmten Ergebnisse entsprechen den Angaben zur Lungenperfusion, wie sie in der Literatur zu finden sind.
Die hypofraktionierte stereotaktische Bestrahlung erlaubt eine präzise hochdosierte und kleinvolumige Radiotherapie umschriebender Raumforderungen mit Tumorkontrollen größer 90% bei peripheren Lungentumoren. Berichtet wird über 70 Patienten mit 86 pulmonalen Läsionen in der Lunge (35 Bronchialkarzinome NSCLC, 51 Metastasen), die zwischen 1997 und 2005 an der Klinik für Strahlentherapie (Universität Würzburg) stereotaktisch bestrahlt wurden. Die Patienten wurden hypofraktioniert mit 3 x 10-12,5 Gy oder mit 1 x 26 Gy (Einzeitbestrahlung) therapiert. Die Morpholgie der pulmonalen Strahlenreaktion sowie deren zeitlicher Verlauf wurden ebenso wie das Tumoransprechen anhand von 346 Verlauf-CTs qualitativ und semiquantitativ ausgewertet. In der Diskussion wurden diese Ergebnisse mit Publikationen zu diesem Thema nach konventioneller Bestrahlung verglichen. Es zeigte sich eine günstiges Verhältnis zwischen Tumorwirksamkeit und Strahlenpneumonitis.
Eine intrauterine Infektion ist eine ernstzunehmende Erkrankung mit möglicherweise schwerwiegenden Folgen für den Feten. Frühgeborene, die einer Chorioamnionitis ausgesetzt waren, haben jedoch eine geringere Mortalitätsrate mit biochemischen und strukturellen Veränderungen während der Lungenentwicklung.
Vorhergehende experimentelle Arbeiten belegen die Initiierung einer Lungenreifung durch intraamniotisch verabreichtes Lipopolysaccharid. Hierbei wurde durch Aspiration der Amnionflüssigkeit eine fetale pulmonale Inflammationsreaktion in Gang gesetzt.
Die Hypothese der vorliegenden Arbeit lautete, dass eine durch intravenös appliziertes Lipopolysaccharid induzierte fetale systemische Inflammation die intrauterine Lungenreifung ebenfalls beeinflusst.
Die im Rahmen dieser Arbeit durchgeführten Versuche erfolgten an 21 fetalen Schafen mit einem Gestationsalter von 107 Tagen. Alle Tiere wurden zunächst mit intrauterinen Kathetern versehen. Nach einer Erholungsphase von 3 Tagen erhielten die Kontrolltiere (N=12) Kochsalzlösung und die Tiere der Versuchsgruppe (N=9) 100ng Lipopolysaccharid intravenös. Lungenstruktur und Lungenreifung der fetalen Schafe wurden mittels biochemischer und histologischer Untersuchungen nach 3 (N=5) und nach 7 (N=4) Tagen beurteilt.
Die Infusion der Lipopolysaccharidlösung hatte zumindest innerhalb des Versuchszeitraums keinen Einfluss auf das Körpergewicht des Feten. Die systemische Entzündung trägt jedoch zu einer pränatalen Verletzung mit strukturellen pulmonalen Veränderungen bei. Sowohl eine Lungenreifung als auch eine gestörte strukturelle Lungenentwicklung traten nach einer kurzfristigen fetalen Inflammation ein.
Die Konzentration an Interleukin-6 in der bronchoalveolären Lavage stieg 3 Tage nach Applikation des Lipopolysaccharids mehr als 40fach an. Sowohl die Prozessierung von Pro-Surfactant Protein (SP)-B zu reifem SP-B als auch erhöhte Konzentrationen an SP-B konnten nach 7 Tagen nachgewiesen werden. Ebenfalls war eine Steigerung des phosphorylierten STAT-3 im Lungengewebe zu erkennen. Die Ablagerung von Elastinfasern an Septierungsstellen der Alveolen wurde innerhalb von 3 Tagen nach Lipopolysaccharidapplikation negativ beeinflusst.
Aus den Erkenntnissen dieser Arbeit könnten neue Therapieansätze sowohl für das Atemnotsyndrom des Frühgeborenen als auch der bronchopulmonalen Dysplasie resultieren, die eine Modulation der Entzündungsreaktion zum Ziel haben. Alle therapeutischen Ansätze werden einen Weg zwischen den positiven Effekten der Lungenreifung mit gesteigerter Compliance, reduzierter Alveolarwanddicke und vermehrtem prozessiertem SP-B und den schädlichen Einwirkungen auf die Lungenstruktur mit veränderter Elastinverteilung und kapillärer Leckage finden müssen. Bedauerlicherweise können die erhobenen Daten nicht klären, ob die einmalige Infusion von LPS eine anhaltende oder permanente Störung der alveolären Entwicklung hervorbringt. Die strukturellen Veränderungen des Lungengewebes, die denen einer BPD ähneln, lassen jedoch eine permanente Organschädigung befürchten.
Hintergrund: Die pulmonale elektrische Impedanztomographie (EIT) stellt die regionale Ventilation der Lunge dar. Ziel dieser Studie war es, die postoperative Umverteilung der regionalen Ventilation nach lungenchirurgischen Eingriffen in Abhängigkeit von der Operationsseite und deren Zusammenhang mit der forcierten Vitalkapazität zu untersuchen.
Methoden: In dieser Beobachtungsstudie wurden Patienten untersucht, die sich rechts- und linksseitig offenen und videothorakoskopischen Eingriffen unterzogen. Es wurden Messungen mit EIT und Spirometrie durchgeführt. Jeweils 13 links- und 13 rechtsseitig operierte erwachsene Patienten, wurden präoperativ, sowie am dritten postoperativen Tag untersucht. Der Center of Ventilation (COV) innerhalb einer 32 x 32 Matrix wurde aus den EIT-Daten berechnet. COVx (links/rechts) wurde zu COVx' (ipsilateral/kontralateral) mit invertiertem Vektor der perioperativen Veränderung bei rechtsseitiger Operation modifiziert, um den Effekt der Zeit und der Seite der Operation in beiden Gruppen mit Two-way ANOVA für wiederholte Messungen zu testen.
Ergebnisse: Die perioperative Verschiebung von COVx' war abhängig von der Operationsseite (p=0,007) und war um -1,97 Matrixpunkte (p<0,001) bei rechtsseitiger und -0,61 Matrixpunkte (p=0,425) bei linksseitiger Operation von der Operationsseite weg gerichtet. Die forcierte Vitalkapazität (%vom Soll) verringerte sich von 94 (83-109) % [Median (Perzentile)] (linksseitig) und 89 (80-97) % (rechtsseitig) auf 61 (59-66) % bzw. 62 (40-72) % (p<0,05) und korrelierte mit COVx' für beide Gruppen.
Schlussfolgerung: Nur nach rechtsseitiger Lungenoperation konnte die EIT eine reduzierte Ventilation auf der Seite der Operation zeigen, während die Vitalkapazität in beiden Gruppen deutlich reduziert war.
Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung
(2019)
In this thesis, a 3D Ultrashort echo time (3D-UTE) sequence was introduced in the Self-gated Non-Contrast-Enhanced Functional Lung Imaging (SENCEFUL) framework. The sequence was developed and implemented on a 3 Tesla MR scanner. The 3D-UTE technique consisted of a nonselective RF pulse followed by a koosh ball quasi-random sampling order of the k-space. Measurements in free-breathing and without contrast agent were performed in healthy subjects and a patient with lung cancer.
A gating technique, using a combination of different coils with high signal correlation, was evaluated in-vivo and compared with a manual approach of coil selection. The gating signal offered an estimation of the breathing motion during measurement and was used as a reference to segment the acquired data into different breathing phases.
Gradient delays and trajectory errors were corrected during post-processing using the Gradient Impulse Response Function. Iterative SENSE was then applied to determine the fully sampled data.
In order to eliminate signal changes caused by motion, a 3D image registration was employed, and the results were compared to a 2D image registration method.
Ventilation was assessed in 3D and regionally quantified by monitoring the signal changes in the lung parenchyma. Finally, image quality and quantitative ventilation values were compared to the standard 2D-SENCEFUL technique.
3D-UTE, combined with an automatic gating technique and SENCEFUL MRI, offered ventilation maps with high spatial resolution and SNR. Compared to the 2D method, UTE-SENCEFUL greatly improved the clinical quality of the structural images and the visualization of the lung parenchyma.
Through‐plane motion, partial volume effects and ventilation artifacts were also reduced with a three-dimensional method for image registration.
UTE-SENCEFUL was also able to quantify regional ventilation and presented similar results to previous studies.
Makrophagen spielen als Zellen der angeborenen Abwehr eine wichtige Rolle bei der Immunabwehr. Ziel dieser Arbeit war die phänotypische und funktionelle Charakterisierung von Alveolarmakrophagen der Ratte. Hierzu wurden die durch eine bronchoalveoläre Lavage gewonnenen Alveolarmakrophagen immunhistologisch und durchflusszytometrisch untersucht. Zusätzlich wurden sie in vitro mit LPS und IFN-g stimuliert. Die Produktion von Stickstoffmonoxid wurde mit dem Griess Reagenz bestimmt und die Expression von iNOS im Immunoblot nachgewiesen. Zudem wurde die Interaktion mit naiven T-Lymphozyten untersucht. Als Vergleichszellen wurden Peritonealmakrophagen verwendet. Bei den aus bronchoalveolären Lavagen gewonnenen Zellen handelte es sich eindeutig um CD68- und CD11b-positive Alveolarmakrophagen. Vollständig aktivierte Alveolarmakrophagen exprimierten zum Teil andere Oberflächenmoleküle als nicht-aktivierte. So stieg nach Stimulierung der Anteil der Makrophagen, die die kostimulatorischen Moleküle CD80 und CD86 exprimierten, auf ca. 80 Prozent an. Ebenso bildeten sie große Mengen an Stickstoffmonoxid (380 μmol/L NO nach 48 Stunden bei 1 μg/mL LPS) und exprimierten auch das Enzym iNOS. Die aktivierten Alveolarmakrophagen waren nicht in der Lage, naive T-Lymphozyten zu aktivieren. Die Stimulierung der Alveolarmakrophagen in vitro hat gezeigt, dass LPS und IFN-g in den getesteten Konzentrationen in der Lage waren, Makrophagen vollständig zu aktivieren. Die zweistufige Aktivierung von Makrophagen durch ein Priming mit IFN-g und eine darauf folgende vollständige Aktivierung mit LPS, ist bei hohen lokalen Konzentrationen auch nur mit LPS bzw. IFN- g möglich. Dies unterstreicht die besondere Bedeutung der beiden Mediatoren für die Aktivierung von Makrophagen.
Das Ziel dieser Arbeit war es, Methoden und Techniken für die morphologische und funktionelle Bildgebung der menschlichen Lunge mittels Kernspintomographie bei Feldstärken von 0,2 Tesla und 1,5 Tesla zu entwickeln und zu optimieren. Bei 0,2 Tesla wurde mittels der gemessenen Relaxationszeiten T1 und T2* eine 2D und eine 3D FLASH Sequenz zur Untersuchung der Lungenmorphologie optimiert. Sauerstoffgestützte Messungen der Relaxationszeiten T1 und T2* sowie eine SpinLabeling Sequenz liefern funktionelle Informationen über den Sauerstofftransfer und die Perfusion der Lungen. Bei 1,5 Tesla wurde die Lungenperfusion mittels MR-Kontrastmittel mit einer 2D und einer 3D Sequenz unter Verwendung der Präbolus Technik quantifiziert. Zudem wurden zwei MR-Navigationstechniken entwickelt, die es ermöglichen Lungenuntersuchungen unter freier Atmung durchzuführen und aus den Daten artefaktfreie Bilder zu rekonstruieren. Diese Techniken können in verschiedenste Sequenzen für die Lungenbildgebung implementiert werden, ohne dass die Messzeit dadurch signifikant verlängert wird.
In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be quantified by means of noise and SNR calculations. An SNR gain can be traded for a reduced scan time, i.e., additional undersampling, or for an enhanced image quality, keeping scan time constant.
Acceleration of MR imaging is especially important in dynamic applications, since these examinations are inherently time-consuming. The impact of wave-CAIPI sampling on image quality and its potential for scan time reduction was investigated for two dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI.
Dynamic 3D Lung MRI
By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans could be enhanced. Volunteer examinations were used to quantify image quality by means of similarity between accelerated and reference images. To this end, the normalized mutual information and the root-mean-square error were chosen as quantitative image similarity measures.
The wave-CAIPI sampling was shown to exhibit superior quality, especially for short scan times. The values of the normalized mutual information were (10.2 +- 7.3)% higher in the wave-CAIPI case -- the root-mean-square error was (18.9 +- 13.2)% lower on average. SNR calculations suggest an average SNR benefit of around 14% for the wave-CAIPI, compared to Cartesian sampling.
Resolution of the lung in 8 breathing states can be achieved in only 2 minutes. By using the wave-CAIPI k-space trajectory, precise tumor delineation and assessment of respiration-induced displacement is facilitated.
Cardiac 4D Flow MRI
In 4D flow MRI, acceleration of the image acquisition is essential to incorporate the corresponding scan protocols into clinical routine. In this work, a retrospective 6-fold acceleration of the image acquisition was realized. Cartesian and wave-CAIPI 4D flow examinations of healthy volunteers were used to quantify uncertainties in flow parameters for the respective sampling schemes.
By employing wave-CAIPI sampling, the estimated errors in flow parameters in 6-fold accelerated scans could be reduced by up to 55%. Noise calculations showed that the noise level in 6-fold accelerated 4D flow acquisitions with wave-CAIPI is 43% lower, compared to Cartesian sampling. Comparisons between Cartesian and wave-CAIPI 4D flow examinations with a prospective acceleration factor R=2 revealed small, but partly statistically significant discrepancies. Differences between 2-fold and 6-fold accelerated wave-CAIPI scans are comparable to the differences between Cartesian and wave-CAIPI examinations at R=2.
Wave-CAIPI 4D flow acquisitions of the aorta could be performed with an average, simulated scan time of under 4 minutes, with reduced uncertainties in flow parameters. Important visualizations of hemodynamic flow patterns in the aorta were only slightly affected by undersampling in the wave-CAIPI case, whereas for Cartesian sampling, considerable discrepancies were observed.
Der Einfluss von Arzneistofftransportern auf die pulmonale Absorption inhalierter Arzneistoffe
(2017)
Arzneistofftransporter ermöglichen endogenen und exogenen Molekülen die Überwindung von Zellmembranen und tragen dadurch zur Aufnahme, Verteilung und Elimination von Arzneistoffen bei. Inhalativ applizierte Wirkstoffe, wie Vertreter aus der Gruppe der Beta-2-Sympathomimetika oder Anticholinergika, zählen zu den Substraten wichtiger, pulmonal exprimierter Arzneistofftransporter. Trotz intensivierter Forschung auf dem Gebiet der Transporter-Expression ist diese im humanen Lungengewebe bisher wenig untersucht und deren pharmakokinetische Auswirkungen auf pulmonal verabreichte Arzneistoffe sind kaum bekannt. Im Rahmen der vorliegenden Arbeit sollte der Einfluss von Arzneistofftransportern auf die pulmonale Absorption inhalierter Arzneistoffe untersucht und Erkenntnisse über deren Expressions-Profil im humanen Lungengewebe gewonnen werden.
Pharmakokinetische Parameter des inhalativen Anticholinergikums Ipratropiumbromid wurden an einem ex vivo Modell der humanen Lunge untersucht. Nach vorheriger Applikation des kompetitiven OCTN1/2-Inhibitors L-Carnitin wurde keine signifikante Reduktion der absorbierten Wirkstoffmenge detektiert. Damit zeigten sich die beiden organischen Kationen/Carnitin-Transporter OCTN1 und OCTN2, anders als bisher vermutet, nicht als primär an der Absorption von Ipratropiumbromid beteiligte Transporter. Infolgedessen wurde die Beteiligung weiterer Transporter hypothetisiert.
Erstmals wurden die am humanen Lungen-Perfusions-Modell gewonnenen pharmakokinetischen Daten zur pulmonalen Absorption in direkter Beziehung zur mRNA- und Protein-Expression von Arzneistofftransportern in den jeweiligen individuellen Gewebeproben betrachtet. Die pulmonale Genexpression des Multidrug Resistance-Related Protein MRP5 wies eine signifikante negative Korrelation mit der Area under the curve (AUC0 – 60 min) von Ipratropiumbromid auf (r = -0,699; p < 0,05), was die Beteiligung von MRP5 an den Umverteilungsprozessen von Ipratropiumbromid in der humanen Lunge nahelegte. Auf Protein-Ebene wurde eine positive Korrelation zwischen der Expression des organischen Kationentransporters OCT3 und der AUC0 – 60 min von Ipratropiumbromid ermittelt (r = 0,7499,p < 0,05), woraus sich eine potentielle Beteiligung von OCT3 an der Aufnahme von Ipratropiumbromid aus dem luminalen Lungenbereich ableiten ließ.
Zur Untermauerung dieser Hypothese wurden Untersuchungen mit stabil transfizierten HEK293-Zellen durchgeführt. Sowohl der organische Kationentransporter OCT1 als auch OCT3 trugen dabei signifikant zu einer erhöhten zellulären Aufnahme der beiden Tritium-markierten Bronchodilatatoren Ipratropiumbromid und Salbutamol bei. Damit wurde für OCT3 zum ersten Mal eine Beteiligung an der zellulären Aufnahme dieser beiden Arzneistoffe nachgewiesen.
Im Kontext der Gendermedizin sind geschlechtsspezifische Unterschiede in der Transporter-Expression von großem Interesse. Inwiefern die drei Sexualsteroidhormone Estradiol, Progesteron und Testosteron einen regulatorischen Effekt auf die mRNA-Expression von Membrantransportern haben, wurde erstmals durch in vitro Inkubationsversuche in physiologischen Hormonkonzentrationen mit der humanen Bronchialepithelzelllinie Calu-3 geprüft. Mittels intensiv optimierter und sorgfältig validierter RT-qPCR-Analytik konnten vor allem nach Inkubation mit weiblichen Sexualhormonen verglichen zu keiner Hormon-Zugabe statistisch signifikante Expressions-Unterschiede detektiert werden: Nach Behandlung mit Estradiol zeigten der Oligopeptid-Transporter PEPT2 (80,8 ± 15,6 %) und OCTN2 (82,8 ± 4,2 %) eine geringere Genexpression, das Multidrug Resistance-Related Protein MRP1 (111,6 ± 9,1 %) sowie OCTN1 (112,9 ± 10,1 %) waren nach Zugabe von Estradiol kombiniert mit Progesteron höher exprimiert als ohne Hormon-Zusatz.
Da Estradiol überdies als Inhibitor des OCT1- und OCT3-vermittelten Transports gilt, wurde die Auswirkung des Hormons, unter anderem in physiologischer Konzentration, auf die Aufnahme von Tritium-markierten Ipratropiumbromid in stabil transfizierte HEK293-Zellen untersucht, wobei tatsächlich eine reduzierte zelluläre Ipratropiumbromid-Aufnahme beobachtet wurde. Somit könnte auch in vivo eine geschlechtsspezifische Inhibition der beiden Transporter stattfinden, wodurch deren Substrate einer geschlechtsspezifisch variierenden Pharmakokinetik unterliegen könnten.
Darüber hinaus wurde in rund 80 humanen Lungengewebsproben die Genexpression von Arzneistofftransportern hinsichtlich geschlechts- und altersspezifischer Unterschiede überprüft. In unter 50-jährigen Männern war das Multidrug-Resistance Protein MDR1 signifikant höher exprimiert verglichen zu Männern von 50 - 60 Jahren. OCT1 war in Patienten von
50 - 60 Jahren signifikant geringer exprimiert als in über 60-Jährigen. Daneben lieferte die Analyse aller Gewebeproben das Genexpressions-Profil von Arzneistofftransportern im humanen Lungengewebe, wobei OCT3 das höchste und OCT2 das geringste mRNA-Expressions-Niveau unter den untersuchten Transportern aufwies. Eine wesentliche Beteiligung von OCT3 an Transportvorgängen im humanen Lungengewebe erschien damit wahrscheinlich.
Resümierend konnte mit der vorliegenden Arbeit ein Beitrag zur Aufklärung des Einflusses von Arzneistofftransportern auf die pulmonale Absorption inhalativ verabreichter Arzneistoffe geleistet werden. Dabei konnte OCT3 erstmals als maßgeblich an der zellulären Aufnahme von Ipratropiumbromid beteiligter Transporter in der humanen Lunge identifiziert werden, womit einerseits die Beteiligung von Arzneistofftransportern an pharmakokinetischen Prozessen in vivo und andererseits die Bedeutung von Arzneistofftransportern für die inhalative Arzneimitteltherapie deutlich wurde.
Aus pharmakokinetischer Sicht sind neben Parametern wie der oralen Bioverfügbarkeit und der systemischen Clearance, für die Effektivität und Sicherheit eines inhalativ angewendeten Wirkstoffes unter anderem das Ausmaß der pulmonalen Deposition und seine pulmonale Umverteilungskinetik entscheidend. Wird eine topische Wirkung des Arzneistoffes angestrebt, so trägt eine lange Verweilzeit des Arzneistoffes im Zielgewebe, verbunden mit einer langsamen Umverteilung in den systemischen Kreislauf zu einer Wirkungsoptimierung mit gleichzeitiger Minimierung systemischer Nebenwirkungen bei. In-vitro- und ex-vivo-Modelle eignen sich hervorragend zur isolierten Untersuchung solcher pharmakokinetischer Vorgänge ohne den Einfluss verschiedener in-vivo-Faktoren, wie der Verteilung in andere Gewebe, Metabolisierungs- oder Eliminationsprozessen. Das Ziel der vorliegenden Arbeit war es daher, Modelle der humanen Lunge zu etablieren bzw. weiterzuentwickeln, die möglichst realitätsnah die Untersuchung der Pharmakokinetik pulmonal applizierter Wirkstoffe ermöglichen.
In dieser Arbeit werden für die Anwendung in der menschlichen Lunge
optimierte Methoden zur Bestimmung von T1- und T2*-Karten diskutiert:
Dc-Gating ermöglicht die Quantifizierung in freier Atmung, wobei für die
T1-Quantifizierung mittels Inversion Recovery eine Korrektur des dc-Signals
entwickelt wurde. Dies hat den Vorteil, dass Parameterkarten aus mehreren
Messungen anhand ihrer dc-Signale passend überlagert werden können. Da T1
und T2* auf unterschiedliche Art und Weise von der Sauerstoffkonzentration
abhängen, verbessert dies die Möglichkeit, ΔT1- und ΔT2*- Differenzkarten aus
Messungen mit unterschiedlichen O2-Konzentrationen im Atemgas zu erstellen.
Die Parameterquantifizierung ist in erster Linie für die Beobachtung von
Krankheitsverläufen interessant, da T1 und T2* absolute, vergleichbare Zahlen
sind. Da T2* deutlich vom Atemzustand abhängt, ist es auch hierfür sinnvoll,
durch Gating identische Atemzustände abzubilden. Um die unterschiedlichen
Einflüsse des Sauerstoffs auf T1 und T2* besser vergleichbar zu machen, wurde
in dieser Arbeit weiterhin eine kombinierte Messung für beide Parameter
implementiert: Da auch diese in freier Atmung stattfindet, profitieren nicht
nur die Differenzkarten von der Überlagerung der Bilder, sondern auch der
Vergleich der ΔT1- und ΔT2*-Karten untereinander.
Messungen mit einer konventionellen kartesischen Methode an COPD-Patienten
unter Raumluft- und 100% Sauerstoffatmung ergaben bei Verwendung identischer
Atemmasken ein deutlich geringeres ΔT1 als in gesunden Probanden. Dass T1 in
der Lunge nicht nur von der Sauerstoffkonzentration sondern auch von der
Gewebezusammensetzung und insbesondere auch dem Blutvolumenanteil abhängt,
zeigte sich hierbei aber auch an den bei COPD im Mittel sehr viel kürzeren
T1-Zeiten bei Raumluft. Die aufgrund emphysematischer Veränderung noch
zusätzlich reduzierte Protonendichte im Parenchym kranker Lungen macht diese
Messungen allerdings besonders schwierig.
Die oben erwähnten Optimierungen der T1-Quantifizierung zielen daher auch
darauf ab, das Signal aus der Lunge zu maximieren, um Patientenmessungen
einfacher zu machen: Messungen in freier Atmung sind für Patienten nicht nur
einfacher, sondern erlauben effektiv auch längere Messzeiten. Insbesondere
wurde aber durch die Entwicklung einer radialen Methode die Echozeit zur
Messung reduziert, um die kurze T2*-Zeit in der Lunge auszugleichen.
Schließlich wurde durch Implementation einer 2D UTE Sequenz die Messung bei
der kürzesten vom Scanner erlaubten Echozeit ermöglicht.
Die Messungen bei ultrakurzen Echozeiten in Probanden zeigten allerdings
deutlich kürzere T1-Zeiten als die zuvor gefundenen oder in der Literatur
dokumentierten. In weiteren Experimenten wurde das sichtbare T1 zu mehreren
Echozeiten mit Hilfe der zur kombinierten Quantifizierung entwickelten
Methode bestimmt. Dabei ergab sich eine Zunahme des gemessenen T1 mit der
Echozeit. Aus diesem Verhalten sowie den gefundenen kürzesten und längsten T1
lässt sich schließen, dass das intra- und extravaskuläre Lungenwasser, also
Blut bzw. das umgebende Gewebe, mit unterschiedlichen T1- und T2*-Zeiten zum
Signal und damit auch dem effektiven T1 beitragen.
Dass das TE der Messung die Gewichtung dieser Kompartimente bestimmt, hat
dabei mehrere Auswirkungen: Einerseits bedeutet dies, dass beim Vergleich von
T1-Messungen in der Lunge stets auch das TE mitbetrachtet werden muss, bei
dem diese durchgeführt wurden. Andererseits lässt sich die Möglichkeit, die
Messung auf die unterschiedlichen Kompartimente abzustimmen, potentiell
ausnutzen, um zusätzliche diagnostische Informationen zu gewinnen: Da T1 vom
Blutvolumenanteil und der Gewebezusammensetzung abhängt, könnte dieser Effekt
helfen, diese beiden Einflüsse zu differenzieren.
Während die in dieser Arbeit beschriebenen Experimente die TE-Abhängigkeit
des sichtbaren T1 in Probanden aufzeigen, liefern sie allerdings noch keine
genaue Erklärung für die möglichen Ursprünge dieses Effekts. Um diese weiter
zu untersuchen, könnten allerdings gezielte Phantom- und in vivo-Experimente
Aufschluss geben: Ein Aufbau, der die Feldverzerrung durch luftgefüllte
Alveolen in Lösungen mit entsprechenden verschiedenen Suszeptibilitäten
nachbildet, reduziert den Unterschied zwischen den Kompartimenten auf T1 und
χ. Eine in vivo-Messung mit möglichst großer Differenz zwischen Ex- und
Inspiration hingegen könnte den Einfluss der Abstände der Kompartimente vom
Gasraum aufzeigen, da die Alveolarwände in tiefer Inspiration am weitesten
gedehnt und daher am dünnsten sind.
Charakterisierung der pulmonalen Pharmakokinetik von Salmeterol und Insulin-like Growth Factor-1
(2015)
Für inhalativ applizierte Arzneimittel spielt das Ausmaß der pulmonalen Absorption eine entscheidende Rolle. Für Substanzen, die lokal in der Lunge wirken sollen, sind für eine gute Wirksamkeit hohe lokale Wirkstoffkonzentrationen, und für eine geringe Nebenwirkungsrate niedrige systemische Plasmaspiegel wichtig. Sollen allerdings Substanzen das Lungenepithel überwinden und im systemischen Kreislauf wirken, ist eine hohe systemische Verfügbarkeit für eine gute Wirkung gewünscht. Das Ziel dieser Studie war es mit in vitro und ex vivo Methoden das Absorptions- und Permeationsverhalten von pulmonal applizierten Substanzen zu studieren.
Der Transportmechanismus über das Lungenepithel des langwirksamen ß2-Agonisten Salmeterol wurde mithilfe des humanen ex vivo Lungenperfusionsmodells untersucht. Die Anwendung von L-Carnitin als Hemmstoff von organischen Kationen/Carnitin Transportern (OCT/N) bewirkte eine Verringerung der pulmonalen Absorption von Salmeterol von ca. 90 %, was auf eine Beteiligung von Transportern, möglicherweise des OCTN2 oder OTCN1, für den Transport von Salmeterol über das Lungenepithel hindeutete. Es wurde somit zum ersten Mal erfolgreich gezeigt, dass Salmeterol wahrscheinlich als Substrat der Transportproteine fungiert und der Übertritt über das Lungenepithel von organischen Kationen/Carnitin Transportern abhängig ist. Bisher wurde eine Interaktion von Salmeterol mit den OCT/N nur in in vitro Versuchen studiert und Salmeterol wurde nur als Hemmstoff und nicht als Substrat untersucht. Die Beteiligung eines Transporters für die pulmonale Absorption von Salmeterol steht außerdem im Einklang mit Untersuchungen über weitere ß2-Agonisten wie das kurzwirksame Salbutamol und das langwirksame GW597901. Somit scheinen sowohl lipophile als auch hydrophile ß2-Agonisten Substrate für die OCT/N zu sein.
Die Fähigkeit von IGF-1, nach pulmonaler Applikation in den systemischen Kreislauf zu gelangen, wurde in der vorliegenden Studie mit Hilfe des Lungenperfusionsmodells untersucht. Das IGF-1 wurde gebunden an Trehalose oder an Fibroin als Pulver verabreicht. Die Trehalose sollte eine schnelle Abgabe des IGF 1 bewirken, und das Fibroin sollte zum einen ein Trägermaterial mit schützenden Eigenschaften für das IGF 1 darstellen, und zum anderen sollte eine mögliche verzögerte Freisetzung von IGF-1 aus Fibroin in einem ex vivo Modell untersucht werden, die in vorausgegangenen in vitro Versuchen über 3 h lang vorhanden war. Das Peptid wurde nach der Applikation sowohl der Trehalosepartikel als auch der Fibroinpartikel pulmonal absorbiert und folgte einer linearen Verteilungskinetik. Dieses lineare Absorptionsverhalten des IGF-1 war vergleichbar mit der Kinetik von inhalativem Insulin, die in in vivo Studien beobachtet wurde. Somit konnte gezeigt werden, dass das IGF-1 nach pulmonaler Applikation systemisch verfügbar sein könnte und eine vergleichbare pulmonale Pharmakokinetik wie das strukturell ähnliche Insulin besitzt. Außerdem unterschied sich das Absorptionsverhalten von IGF-1, gebunden an Trehalose, nicht signifikant von dem von IGF-1/Fibroin, was im Gegensatz zu in vitro Untersuchungen stand, in denen das IGF-1 verzögert aus Fibroin freigesetzt wurde. Somit wirkte sich die kontrollierte Abgabe in vitro nicht auf die Verteilungskinetik ex vivo aus. Daraus ergibt sich, dass sowohl Trehalose als auch Fibroin als Trägermaterial für IGF-1 zur pulmonalen Applikation geeignet wären, und dass IGF-1, gebunden an Fibroin eine Formulierung wäre, die zum einen das IGF 1 schützen kann und die zum anderen eine gleiche pulmonale Kinetik wie IGF 1, gebunden an schnell auflösende Trägersubstanzen, besitzt. Außerdem wurde dadurch die Wichtigkeit betont, die Pharmakokinetik von pulmonal verabreichten Substanzen am intakten Organ mit erhaltener Komplexität und Funktionalität zu untersuchen, und dass das Lungenperfusionsmodell hierfür eine geeignete Methode darstellt. Darüber hinaus wurde belegt, dass mithilfe des Lungenperfusionsmodells erfolgreich pharmakokinetische Daten für nieder- und höhermolekulare Substanzen gesammelt werden können, die als Aerosol oder als Pulver appliziert werden.
Auch in den in der vorliegenden Arbeit durchgeführten in vitro Permeationsversuchen, die mit der Bronchialepithelzelllinie Calu-3 durchgeführt wurden, zeigte IGF-1 vergleichbare lineare Permeationseigenschaften wie das Insulin, mit einem apparenten Permeationskoeffizienten von 1,49 * 10-8 cm/sec für IGF-1 und 2,11 * 10-8 cm/sec für Insulin. Das IGF 1 schien durch die Calu-3 Zellen sowohl parazellulär als auch transzytotisch zu permeieren, wie es für Makromoleküle generell vermutet wird. Durch die Verwendung von Hemmstoffen der Transzytose bzw. bestimmter endozytotischer Mechanismen in den Permeationsstudien konnte gezeigt werden, dass, wie bereits genannt, der Transport durch die Zellen eine wichtige Rolle für den Übertritt von IGF-1 über Calu-3 Zellmonolayer spielte. Die Studien ergaben außerdem, dass die zelluläre Aufnahme des IGF-1 unabhängig von Clathrin und abhängig von Dynamin war.
Der Einsatz einer humanen bronchioalveolären Lavage in den Permeationsversuchen bewirkte zum einen eine Erhöhung des Transportes von IGF 1 durch die Calu-3 Zellen, und zum anderen war die zelluläre Aufnahme in diesem Fall unabhängig von Dynamin und unterschied sich somit von den vorherigen Untersuchungen, in denen keine Lavage eingesetzt wurde. Das bedeutet, dass Faktoren in einer bronchioalveolaren Lavage enthalten waren, die sowohl das Ausmaß der Permeation als auch den Mechanismus der zellulären Aufnahme von IGF-1 in Calu-3 Zellen beeinflussten.
Zusammenfassend konnten in der vorliegenden Arbeit erfolgreich weitere Hinweise für die Beteiligung von Transportern an der pulmonalen Absorption von ß2-Agonisten mithilfe des ex vivo Lungenperfusionsmodells gefunden werden, was somit eine wertvolle Ergänzung zu bisher vorhanden in vitro Studien darstellt. Daneben wurde zum ersten Mal gezeigt, dass das IGF-1 nach Applikation in die Lunge pulmonal absorbiert werden könnte. Das belegt den Nutzen der Lunge als Eintrittsort in den systemischen Kreislauf, was vor allem für peptidische Arzneistoffe von Bedeutung ist.
Zur Beurteilung der Lungenanatomie wurde das MT-STIR-Verfahren vorgestellt. Es wurde gezeigt, dass das MT-STIR-Verfahren das störende Signal des umgebenden Muskelgewebes effektiv unterdrückt und damit die Visualisierung des Lungenparenchyms verbessert. Im Vergleich zu konventionellen anatomischen 1H-MR-Verfahren wie IR- und MIR-Verfahren erhöht das MT-STIR-Verfahren das Signal-zu-Rausch-Verhältnis (SNR) des Lungenparenchyms signifikant und vermeidet den Signalausfall des Lungenparenchyms aufgrund der pathologischen Verkürzung der Lungen-T1-Relaxationszeit auf ca. 900 ms wie bei Patienten mit Mukoviszidose (CF), so dass sowohl große Lungenperfusionsdefekte in Patienten mit CF als auch kleine ungefährliche Lungenentzündungen in „gesunden“ Probanden durch das MT-STIR-Verfahren gut dargestellt werden können. Für die indirekte, aber quantitative Beurteilung der Lungenventilation wurde die oben genannte schnelle quantitative Lungen-T1-Mapping-Technik während der Inhalation eines Atemgasgemisches mit verschiedenen O2-Konzentrationen (21%, 40%, 60%, 80% und 100%) eingesetzt. Dabei ist im Blut physikalisch gelöster Sauerstoff leicht paramagnetisch und dient als Blut-T1-verkürzendes MR-Kontrastmittel (KM). In der Lunge ist das Blut die Hauptquelle des freien Wassers, so dass Lungen-T1-Werte nach dem Zwei-Kompartimente-Schnellaustausch-Modell der Lungen-T1-Relaxationszeit durch den Blut-T1-Wert beeinflusst werden. Die zugehörige Theorie, ein O2-gestütztes Lungen-T1-Modell, wurde aus der Lungenphysiologie und den T1-Relaxationsmechanismen hergeleitet und zeigt, dass bei Probanden die Lungen-T1-Verkürzung von 21% O2 zu 100% O2 ca. 11% beträgt und die Beziehung zwischen dem Lungen-R1 (= 1/T1)-Wert und der inhalierten O2-Konzentration linear mit einer Steigung von 0,12 1/s und einem R1-Achsenabschnitt von 0,70 1/s ist. Die Steigung wurde im Rahmen dieser Doktorarbeit als oxygen transfer function (OTF) definiert und ist vom gasaustauschbestimmenden Ventilations-Perfusions- und Diffusions-Perfusions-Verhältnis abhängig, so dass sie praktisch ein Maß für den pulmonalen Gasaustausch darstellt. Experimentell wurde gezeigt, dass Lungen-T1-Werte bei 100% O2 um 10% kürzer als bei 21% O2 sind, was gut mit dem O2-gestützten Lungen-T1-Modell übereinstimmt. Weiterhin wurde die OTF dadurch bestimmt, dass die gemessenen Lungen-R1-Werte gegen die inhalierte O2-Konzentration aufgetragen wurden und eine Gerade an die Messpunkte angepasst wurde. Gesundes Lungenparenchym von Probanden und gut perfundiertes Lungenparenchym von Patienten mit CF zeigten OTF-Werte zwischen 0,10 und 0,14 1/s, R1-Achsenabschnitte zwischen 0,70 und 0,80 1/s und ausgezeichnete Korrelationskoeffizienten von annähernd 1,00, was mit dem O2-gestützten Lungen-T1-Modell übereinstimmt. Schlecht perfundiertes Lungenparenchym von Patienten mit CF zeigte eindeutig erniedrigte OTF-Werte, erhöhte R1-Achsenabschnitte und schlechte Korrelationskoeffizienten. Das O2-gestützte Lungen-T1-Mapping-Verfahren zeigt eine hohe Reproduzierbarkeit. Zur Beurteilung der Lungenperfusion wurde eine quantitative Perfusionsmapping-Technik mittels Protonen-Spin-Labeling, ohne Verwendung eines intravenösen Kontrastmittels wie Gadolinium (Gd)-DTPA, vorgestellt. Aus einer nicht-schichtselektiven (globalen) T1-Map und einer schichtselektiven T1-Map derselben Lungenschicht, die jeweils mit der oben genannten schnellen quantitativen Lungen-T1-Mapping-Technik akquiriert wurde, wurde eine Perfusionamap berechnet, wobei jedes Pixel in der Perfusionsmap eine Perfusionsrate in Einheiten von m/100g/min hat. Es wurde demonstriert, dass die hintere coronale Lungenschicht eine höhere Perfusionsrate als die vordere coronale Lungenschicht desselben Probanden hatte, als er in Rückenlage gemessen wurde, was den Gravitationseffekt auf die Lungenperfusion bestätigt. Die berechneten Perfusionsraten des gut perfundierten Lungenparenchyms von Probanden und von Patienten mit CF lagen zwischen 400 und 600 m/100g/min, die gut mit dem Literaturwert übereinstimmen. Die berechneten Perfusionsraten des schlecht perfundierten Lungenparenchyms von Patienten mit CF waren niedriger als 200 m/100g/min. Die Spin-Labeling-Technik zeigte eine hohe Reproduzierbarkeit und niedrige relative Fehler der berechneten Perfusionsraten.
Ziel dieser Arbeit war es, das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung mittels der MRT darzustellen. Um trotz der niedrigen Protonendichte der Lunge und der geforderten hohen Auflösung ausreichend Signal für eine verlässliche Diagnostik zu erhalten, sind Aufnahmezeiten von einigen Minuten nötig. Um die Untersuchung für den Patienten angenehmer zu gestalten oder auf Grund der eingeschränkten Fähigkeit eines Atemstopps überhaupt erst zu ermöglichen, war eine Anforderung, die Aufnahmen in freier Atmung durchzuführen. Dadurch entstehen allerdings Bewegungsartefakte, die die Diagnostik stark beeinträchtigen
und daher möglichst vermieden werden müssen. Für eine Bewegungskompensation
der Daten muss die auftretende Atembewegung detektiert werden. Die Bewegungsdetektion
kann durch externe Messgeräte (Atemgurt oder Spirometer) oder durch eine
zusätzliche Anregungen erfolgen (konventionelle Navigatoren) erfolgen. Nachteile
dieser Methoden bestehen darin, dass die Bewegung während der Atmung nicht
direkt verfolgt wird, dass elektronische Messgeräte in die Nähe des Tomographen
gebracht werden und das die Patienten zusätzlich vorbereitet und eingeschränkt
werden. Des Weiteren erfordert eine zusätzliche Anregung extra Messzeit und kann
unter Umständen die Magnetisierung auf unterwünschte Weise beeinflussen.
Um die angesprochenen Schwierigkeiten der Bewegungsdetektion zu umgehen,
wurden in dieser Arbeit innerhalb einer Anregung einer 3d FLASH-Sequenz sowohl
Bilddaten- als auch Navigatordaten aufgenommen. Als Navigator diente dabei das
nach der Rephasierung aller bildgebenden Gradienten entstehende Signal (DC Signal).
Das DC Signal entspricht dabei der Summe aller Signale, die mit einem bestimmten
Spulenelement detektiert werden können. Bewegt sich beispielsweise die Leber
bedingt durch die Atmung in den Sensitivitätsbereich eines Spulenelementes, wird
ein stärkeres DC Signal detektiert werden. Je nach Positionierung auf dem Körper
kann so die Atembewegung mit einzelnen räumlich lokalisierten Spulenelementen
nachverfolgt werden. Am DC Signalverlauf des für die Bewegungskorrektur ausgewählten
Spulenelementes sind dann periodische Signalschwankungen zu erkennen.
Zusätzlich können aus dem Verlauf Expirations- von Inspirationszuständen unterschieden
werden, da sich Endexpirationszustände im Regelfall durch eine längere
Verweildauer auszeichnen.
Grundsätzlich kann das DC Signal vor oder nach der eigentlichen Datenaufnahme
innerhalb einer Anregung aufgenommen werden. Auf Grund der kurzen Relaxationszeit
T∗2 des Lungengewebes fällt das Signal nach der RF Anregung sehr schnell ab. Um
möglichst viel Signal zu erhalten sollten, wie in dieser Arbeit gezeigt wurde, innerhalb einer Anregung zuerst die Bilddaten und danach die Navigatordaten aufgenommen
werden. Dieser Ansatz führt zu einer Verkürzung der Echozeit TE um 0.3 ms und
damit zu einem SNR Gewinn von etwa 20 %. Gleichzeitig ist das verbleibende Signal
nach der Datenakquisition und Rephasierung der bildgebenden Gradienten noch
ausreichend um die Atembewegung zu erfassen und somit eine Bewegungskorrektur
der Daten (Navigation) zu ermöglichen.
Um eine retrospektive Bewegungskorrektur durchführen zu können, müssen Akzeptanzbedingungen
(Schwellenwerte) für die Datenauswahl festgelegt werden. Bei
der Wahl des Schwellenwertes ist darauf zu achten, dass weder zu wenige noch zu
viele Daten akzeptiert werden. Akzeptiert man sehr wenige Daten, zeichnen sich die
Rekonstruktionen durch einen scharfen Übergang zwischen Lunge und Diaphragma
aus, da man sehr wenig Bewegung in den Rekonstruktionen erlaubt. Gleichzeitig
erhöht sich allerdings das Risiko, dass nach der Navigation Linien fehlen. Dies führt
zu Einfaltungsartefakten, die in Form von gestörten Bildintensitäten in den Rekonstruktionen
zu sehen sind und die diagnostische Aussagekraft einschränken. Um
Einfaltungsartefakte zu vermeiden sollte der Schwellenwert so gewählt werden, dass
nach der Datenauswahl keine Linien fehlen. Aus dieser Anforderung lässt sich ein
maximaler Schwellenwert ableiten. Akzeptiert man dagegen sehr viele Daten, zeichnen
sich die Rekonstruktionen durch erhöhtes Signal und das vermehrte Auftreten
von Bewegungsartefakten aus. In diesem Fall müsste der Arzt entscheiden, ob Bewegungsartefakte
die Diagnostik zu stark beeinflussen. Wählt man den Schwellenwert
so, dass weder Linien fehlen noch zu viel Bewegung erlaubt wird, erhält man Rekonstruktionen
die sich durch einen scharfen Diaphragmaübergang auszeichnen und in
denen noch kleinste Gefäße auch in der Nähe des Diaphragmas deutlich zu erkennen
sind. Hierfür haben sich Schwellenwerte, die zu einer Datenakzeptanz von ca. 40 %
führen als günstig erwiesen.
Um Einfaltungsartefakte auf Grund der retrospektiven Datenauswahl zu verhindern,
muss das Bildgebungsvolumen mehrfach abgetastet werden. Dadurch wird
gewährleistet, dass für die letztendliche Rekonstruktion ausreichend Daten zur Verfügung
stehen, wobei mehrfach akzeptierte Daten gemittelt werden. Dies spielt auf
Grund der niedrigen Protonendichte der Lunge eine wesentliche Rolle in der Rekonstruktion
hochaufgelöster Lungendatensätze. Weiterhin führt das Mitteln von
mehrfach akzeptierten Daten zu einer Unterdrückung der sogenannten Ghost Artefakte,
was am Beispiel der Herzbewegung in der Arbeit gezeigt wird.
Da die Messungen unter freier Atmung durchgeführt werden und keine zusätzlichen
externen Messgeräte angeschlossen werden müssen, stellte die Untersuchung
für die Patienten in dieser Arbeit kein Problem dar. Im ersten Teil dieser wurde Arbeit
gezeigt, dass sich mit Hilfe des DC Signales als Navigator und einer retrospektiven
Datenauswahl das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung
von beispielsweise 1.6 x 1.6 x 4 mm3 innerhalb von 13 min. darstellen lässt. Die Anwendbarkeit der vorgestellten Methode zur Bewegungskorrektur wurde neben
Probanden auch an Patienten demonstriert.
Da wie bereits beschrieben das Bildgebungsvolumen mehrfach abgetastet werden
muss, wiederholt sich auch die Abfolge der für die Bildgebung verantwortlichen
Gradienten periodisch. Da sich der Atemzyklus aber auch periodisch wiederholt,
kann es zu Korrelationen zwischen der Atmung und den wiederholten Messungen
kommen. Dies führt dazu, dass auch nach vielen wiederholten Messungen immer
noch größere Bereiche fehlender Linien im k-Raum bleiben, was zu Artefakten in
den Rekonstruktionen führt. Dies konnte im Falle der konventionellen Bewegungskorrektur
in den Gatingmasken, die die Verteilung und Häufigkeit der einzelnen
akzeptierten Phasenkodierschritte im k-Raum zeigen, beobachtet werden.
Da eine vorsätzliche Unterbrechung der Atemperiodizität (der Patient wird dazu
angehalten, seine Atemfrequenz während der Messung absichtlich zu variieren) zur
Vermeidung der angesprochenen Korrelationen nicht in Frage kommt, musste die
Periodizität in der Datenaufnahme unterbrochen werden. In dieser Arbeit wurde
dies durch eine quasizufällige Auswahl von Phasen- und Partitionskodiergradienten
erreicht, da Quasizufallszahlen so generiert werden, dass sie unabhängig von ihrer
Anzahl einen Raum möglichst gleichförmig ausfüllen. Die quasizufällige Datenaufnahme
führt deshalb dazu, das sowohl akzeptierte als auch fehlende Linien nach der
Bewegungskorrektur homogen im k-Raum verteilt auftreten.
Vergleicht man das auftreten von Ghosting zeichnen sich die quasizufälligen Rekonstruktionen
im Vergleich zur konventionellen Datenaufnahme durch eine verbesserte
Reduktion von Ghost Artefakten aus. Dies ist auf die homogene Verteilung mehrfach
akzeptierter Linien im k-Raum zurückzuführen. Die homogenere Verteilung von
fehlenden Linien im k-Raum führt weiterhin zu einer wesentlich stabileren Rekonstruktion
fehlender Linien mit parallelen MRT-Verfahren (z.B. iterativem Grappa).
Dies wird umso deutlicher je höher der Anteil fehlender Linien im k-Raum wird. Im
Falle der konventionellen Datenaufnahme werden die zusammenhängenden Bereiche
fehlender Linien immer größer, was eine erfolgreiche Rekonstruktion mit iterativem
Grappa unmöglich macht. Im Falle der quasizufälligen Datenaufnahme dagegen
können auch Datensätze in denen 40% der Linien fehlen einfaltungsartefaktfrei
rekonstruiert werden.
Im weiteren Verlauf der Arbeit wurde gezeigt, wie die Stabilität der iterativen Grappa
Rekonstruktion im Falle der quasizufälligen Datenaufnahme für eine erhebliche
Reduktion der gesamten Messzeit genutzt werden kann. So ist in einer Messzeit von
nur 74s die Rekonstruktion eines artefaktfreien und bewegungskorrigierten dreidimensionalen
Datensatzes der menschlichen Lunge mit einer Auflösung von 2 x 2 x
5 mm3 möglich. Des Weiteren erlaubt die quasizufällige Datenaufnahme in Kombination
mit iterativem Grappa die Rekonstruktion von Datensätzen unterschiedlicher
Atemphasen von Inspiration bis Expiration (4D Bildgebung). Nach einer Messzeit
von 15min. wurden 19 unterschiedliche Atemzustände rekonstruiert, wobei sich der Anteil der fehlenden Linien zwischen 0 und 20 % lag. Im Falle der konventionellen
Datenaufnahme wäre eine wesentlich längere Messzeit nötig gewesen, um ähnliche
Ergebnisse zu erhalten.
Zum Schluss soll noch ein Ausblick über mögliche Weiterentwicklungen und Anwendungsmöglichkeiten,
die sich aus den Erkenntnissen dieser Arbeit ergeben haben,
gegeben werden. So könnte das quasizufällige Aufnahmeschema um eine Dichtegewichtung
erweitert werden. Hierbei würde der zentrale k-Raum Bereich etwas
häufiger als die peripheren Bereiche akquiriert werden. Dadurch sollte die iterative
Grappa Rekonstruktion noch stabiler funktionieren und Ghost Artefakte besser reduziert
werden. Die Verteilung der Linien sollte allerdings nicht zu inhomogen werden,
um größere Lücken im k-Raum zu vermeiden.
Darüber hinaus könnte die vorgestellte Methode der Bewegungskompensation
auch für die Untersuchung anderer Organe oder Körperteile verwendet werden.
Voraussetzung wäre lediglich das Vorhandensein dezidierter Spulenanordnungen,
mit denen die Bewegung nachverfolgt werden kann. So ist beispielsweise eine dynamische
Bildgebung des frei und aktiv bewegten Knies möglich, wobei zwischen
Beugung und Streckung durch die erste Ableitung des zentralen k-Raum Signales
unterschieden werden kann. Dies kann zusätzliche Diagnoseinformationen liefern
oder für Verlaufskontrollen nach Operationen benutzt werden [15].
Eine Weiterentwicklung mit hohem klinischen Potential könnte die Kombination
der in dieser Arbeit vorgestellten retrospektiven Bewegungskorrektur mit einer Multi-
Gradienten-Echo Sequenz darstellen. Hierzu musste die bestehende Sequenz lediglich
um eine mehrfache Abfolge von Auslesegradienten innerhalb einer Anregung erweitert
werden. Dies ermöglicht eine bewegungskorrigierte voxelweise Bestimmung der
transversalen Relaxationszeit T∗2 in hoher räumlicher Auflösung. Unter zusätzlicher
Sauerstoffgabe kann es zu einer Veränderung von T∗2 kommen, die auf den sogenannten
BOLD Effekt (Blood Oxygen Level Dependent) zurückzuführen ist. Aus dieser
Änderung könnten Rückschlüsse auf hypoxische Tumorareale gezogen werden. Da
diese eine erhöhte Strahlenresistenz aufweisen, könnte auf diese Bereiche innerhalb
des Tumors eine erhöhte Strahlendosis appliziert und so möglicherweise Behandlungsmisserfolge
reduziert werden. Gleichzeitig kann durch die 4D Bildgebung eine
mögliche Tumorbewegung durch die Atmung erfasst und diese Information ebenfalls
in der Bestrahlungsplanung benutzt werden. Die Lungen MRT könnte somit um eine
hochaufgelöste dreidimensionale funktionelle Bildgebung erweitert werden.