Refine
Has Fulltext
- yes (44)
Is part of the Bibliography
- yes (44)
Year of publication
- 2022 (44) (remove)
Document Type
- Doctoral Thesis (23)
- Journal article (20)
- Master Thesis (1)
Keywords
- Topologischer Isolator (7)
- HgTe (5)
- Quecksilbertellurid (5)
- topological insulator (4)
- Elektronentransport (3)
- Exziton-Polariton (3)
- molecular beam epitaxy (3)
- Elektronenspinresonanz (2)
- Fourier-Spektroskopie (2)
- Laser (2)
- Optischer Resonator (2)
- Organischer Halbleiter (2)
- Perowskit (2)
- Photoelektronenspektroskopie (2)
- Röntgen-Photoelektronenspektroskopie (2)
- Topologie (2)
- Zweidimensionales Material (2)
- cardiac (2)
- magnetic resonance imaging (2)
- nanoparticles (2)
- photoelectron spectroscopy (2)
- radial (2)
- resonant tunneling diode (2)
- thin films (2)
- 3D analysis (1)
- 3D printing (1)
- ARPES (1)
- Absorptionsspektroskopie (1)
- Adaptive Optics (1)
- Adaptive Optik (1)
- Aharonov-Bohm (1)
- AlGaAs (1)
- Atherosclerosis, intracranial arteries (1)
- Axion (1)
- Bildgebendes Verfahren (1)
- Bismuthene (1)
- Bismutselenide (1)
- Bornitrid (1)
- Boron Nitride (1)
- CdTe (1)
- CePt5 (1)
- Cerlegierung (1)
- Core-shell (1)
- Crystal (1)
- Cu(111) (1)
- Dirac semimetal (1)
- Drei-Fünf-Halbleiter (1)
- Dreidimensionale Rekonstruktion (1)
- Einzelmolekülmikroskopie (1)
- Einzelphotonenemission (1)
- Electron Paramagnetic Resonance (1)
- Electron spin (1)
- Elektronenkorrelation (1)
- Elektronenspin (1)
- Elektronischer Transport (1)
- External-Cavity Quantum Cascade Laser (1)
- Externer-Kavitäts-Quanten-Kaskaden-Laser (1)
- FDTD Simulation (1)
- Faserorientierung (1)
- Fatigue (1)
- Fiber Orientation (1)
- Fluoreszenz (1)
- Fluoreszenzlebensdauer-Mikroskopie (1)
- Fluoreszenzmikroskopie (1)
- Gas mixtures (1)
- Gaseous Hydrocarbons (1)
- Gasförmige Kohlenwasserstoffe (1)
- Gasgemisch (1)
- Gittersimulator (1)
- Gunnarsson Schönhammer (1)
- HPc (1)
- Halbleiter-Supraleiter-Kontakt (1)
- Hemisphärische Kavität (1)
- III–V semiconductor devices (1)
- Imaging spin-filter (1)
- In situ (1)
- Inversion Symmetry Breaking (1)
- KWIC (1)
- Kondo (1)
- Konfokale Mikroskopie (1)
- Korrelation (1)
- Kristall (1)
- Laser absorption spectroscopy (1)
- Laserabsorptionspektroskopie (1)
- Laserspektroskopie (1)
- Luttinger liquid (1)
- MIR spectroscopy (1)
- MIR-Spektroskopie (1)
- Magnetic Topological Insulator (1)
- Meniere’s disease (1)
- Microscopy (1)
- Mikrocomputertomographie (1)
- Mikroresonator (1)
- Mikroskopie (1)
- Molecular beam epitaxy (1)
- Momentum- and spin-resolved hard X-ray photoelectron spectroscopy (1)
- Mustervergleich (1)
- Nanodraht (1)
- Nanometerbereich (1)
- Nanowires (1)
- OLED (1)
- Oberflächenlegierung (1)
- Oberflächenzustand (1)
- Optik (1)
- Orbital Angular Momentum (1)
- Organic Light Emitting Diode (1)
- Organic Photovoltaic (1)
- Organische Leuchtdioden (1)
- Pattern Matching (1)
- Perovskite (1)
- Photolumineszenz (1)
- Polariton Lasing (1)
- Quantenkaskadenlaser (1)
- Quantenwell (1)
- Quantum anomalous Hall effect (1)
- Rashba-Effekt (1)
- Rastertunnelmikroskopie (1)
- Rotary EXcitation (REX) (1)
- STED-Mikroskopie (1)
- Schwache Kopplung (1)
- Shapiro (1)
- Silicon Carbide (1)
- Siliziumcarbid (1)
- Single Molecule Localization Microscopy (1)
- Spin-Orbit Coupling (1)
- Spinell (1)
- Surface states (1)
- T1rho (1)
- T1ρ (1)
- TCSPC (1)
- TT\(_{1rho}\) mapping (1)
- T\(_{1P}\) dispersion (1)
- T\(_{1P}\) mapping (1)
- Technische Optik (1)
- Tensor (1)
- Tensor Tomography (1)
- Time-of-flight energy recording (1)
- Tomografie (1)
- Topologische Laser (1)
- Transportprozess (1)
- Ultraviolett-Photoelektronenspektroskopie (1)
- Vapor-liquid-solid (1)
- Volkov-Pankratov states (1)
- Volume Reconstruction (1)
- Winkel- und spin-aufgelöste Photoelektronenspektroskopie im harten Röntgenbereich (1)
- X-Ray Dark-Field (1)
- XPS (1)
- Zahnimplantat (1)
- ZnTe (1)
- band structure (1)
- biochemical assays (1)
- biomaterials (1)
- carbon nanotubes (1)
- catalysis (1)
- catalyst (1)
- characterization and analytical techniques (1)
- coherent multidimensional spectroscopy (1)
- computed tomography (1)
- coronary arteries (1)
- correction (1)
- correlated oxides (1)
- correlation (1)
- covalent organic framework (1)
- crystalline (1)
- dSTORM (1)
- dental implant (1)
- electrochemistry (1)
- electron-hole scattering (1)
- electronic phase transitions (1)
- exciton (1)
- fatigue (1)
- functional magnetic resonance imaging (1)
- helical edge states (1)
- honeycomb lattice (1)
- image processing (1)
- impedance spectroscopy (1)
- in vivo imaging (1)
- interplay of surface states (1)
- large artery vasculitis (1)
- laser spectroscopy (1)
- magnetic properties and materials (1)
- mapping (1)
- maser (1)
- medical device (1)
- melt electrowriting (1)
- metamorphic buffer layer (1)
- mice (1)
- microtomography (1)
- mid-infrared sensing (1)
- multichromophores (1)
- organic light emitting diodes (1)
- oscillating biomagnetic fields (1)
- perylene dyes (1)
- photoluminescence (1)
- photon counting (1)
- photon‐correlation (1)
- photoreflectance (1)
- photosensor (1)
- polymer electrolytes (1)
- population inversion (1)
- quantitative MRI (1)
- quantum dot (1)
- quantum interference (1)
- quantum point contact (1)
- quantum spin hall insulator (1)
- sFLIM (1)
- saccotomy (1)
- scanning tunneling spectroscopy (1)
- signal to noise ratio (1)
- silicon vacancy (1)
- single photon emission (1)
- single-photon detectors (1)
- small animal (1)
- spin lock (1)
- spin polarization (1)
- spin transport (1)
- spin-lock (1)
- stenosis (1)
- stimulated emission (1)
- strong coupling (1)
- subcutaneous implanation (1)
- superradiance (1)
- surface states (1)
- sustainable energy source (1)
- tautomerization (1)
- temporal bone (1)
- ternary organic solar cells (1)
- thermoelectric characterization (1)
- thermoelectric generators (1)
- thorax (1)
- thulium telluride (1)
- topological insulators (1)
- topological surface states (1)
- transition metal dichalcogenide (1)
- transition metal oxides (1)
- two-dimensional materials (1)
- two-dimensional topological insulator (1)
- vasa vasorum (1)
- vertebral artery (1)
- vestibular aqueduct (VA) (1)
- water oxidation (1)
- x-ray micro computed tomography (1)
Institute
- Physikalisches Institut (44) (remove)
Sonstige beteiligte Institutionen
- Wilhelm-Conrad-Röntgen-Forschungszentrum für komplexe Materialsysteme (2)
- Arizona State University, Tempe, Arizona, USA (1)
- Department of Cellular Therapies, University of Navarra, Pamplona, Spain (1)
- Department of X-ray Microscopy, University of Würzburg, Würzburg, Germany (1)
- Fraunhofer-Institute for Applied Optics and Precision Engineering IOF Jena, Germany (1)
- Friedrich Schiller University Jena, Germany (1)
- Max Planck School of Photonics Jena, Germany (1)
- National Institute for Materials Science, Tsukuba, Japan (1)
- Siemens Corporate Technology Munich (1)
- University of Oldenburg, Germany (1)
Thermoelectric materials utilizing ionic transport open-up entirely new possibilities for the recuperation of waste heat. Remarkably, solid state electrolytes which have entered the focus of battery research in recent years turn-out to be promising candidates also for ionic thermoelectrics. Here, the dynamics of ionic transport and thermoelectric properties of a methacrylate based polymer blend in combination with a lithium salt is analyzed. Impedance spectroscopy data indicates the presence of just one transport mechanism irrespective of lithium salt concentration. In contrast, the temperature dependent ionic conductivity increases with salt concentration and can be ascribed to a Vogel–Fulcher–Tammann (VFT) behavior. The obtained Seebeck coefficients of 2 mV K\(^{−1}\) allow for high power outputs while the polymer matrix maintains the temperature gradient by its low thermal conductivity. Adding multi-walled carbon nanotubes to the polymer matrix allows for variation of the Seebeck coefficient as well as the ionic and electronic conductivities. As a result, a transition between a high temperature VFT regime and a low temperature Arrhenius regime appears at a critical temperature, T\(_{c}\), shifting upon addition of salt. The observed polarity change in Seebeck voltage at T\(_{c}\) suggests a new mode of thermoelectric operation, which is demonstrated by a proof-of-concept mixed electronic-ionic-thermoelectric generator.
Objectives
Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort.
Methods
Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE.
Results
Concentric VWE of the proximal intradural ICA was found in 13 (30%) patients, and of the proximal intradural VA in 39 (91%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 %), morphology indicated atherosclerotic lesions in addition to vasa vasorum.
Conclusions
Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis.
Improved radiological examinations with newly developed 3D models may increase understanding of Meniere's disease (MD). The morphology and course of the vestibular aqueduct (VA) in the temporal bone might be related to the severity of MD. The presented study explored, if the VA of MD and non-MD patients can be grouped relative to its angle to the semicircular canals (SCC) and length using a 3D model. Scans of temporal bone specimens (TBS) were performed using micro-CT and micro flat panel volume computed tomography (mfpVCT). Furthermore, scans were carried out in patients and TBS by computed tomography (CT). The angle between the VA and the three SCC, as well as the length of the VA were measured. From these data, a 3D model was constructed to develop the vestibular aqueduct score (VAS). Using different imaging modalities it was demonstrated that angle measurements of the VA are reliable and can be effectively used for detailed diagnostic investigation. To test the clinical relevance, the VAS was applied on MD and on non-MD patients. Length and angle values from MD patients differed from non-MD patients. In MD patients, significantly higher numbers of VAs could be assigned to a distinct group of the VAS. In addition, it was tested, whether the outcome of a treatment option for MD can be correlated to the VAS.
X-ray dark-field imaging allows to resolve the conflict between the demand for centimeter scaled fields of view and the spatial resolution required for the characterization of fibrous materials structured on the micrometer scale. It draws on the ability of X-ray Talbot interferometers to provide full field images of a sample's ultra small angle scattering properties, bridging a gap of multiple orders of magnitude between the imaging resolution and the contrasted structure scale. The correspondence between shape anisotropy and oriented scattering thereby allows to infer orientations within a sample's microstructure below the imaging resolution. First demonstrations have shown the general feasibility of doing so in a tomographic fashion, based on various heuristic signal models and reconstruction approaches. Here, both a verified model of the signal anisotropy and a reconstruction technique practicable for general imaging geometries and large tensor valued volumes is developed based on in-depth reviews of dark-field imaging and tomographic reconstruction techniques.
To this end, a wide interdisciplinary field of imaging and reconstruction methodologies is revisited. To begin with, a novel introduction to the mathematical description of perspective projections provides essential insights into the relations between the tangible real space properties of cone beam imaging geometries and their technically relevant description in terms of homogeneous coordinates and projection matrices. Based on these fundamentals, a novel auto-calibration approach is developed, facilitating the practical determination of perspective imaging geometries with minimal experimental constraints. A corresponding generalized formulation of the widely employed Feldkamp algorithm is given, allowing fast and flexible volume reconstructions from arbitrary tomographic imaging geometries. Iterative reconstruction techniques are likewise introduced for general projection geometries, with a particular focus on the efficient evaluation of the forward problem associated with tomographic imaging. A highly performant 3D generalization of Joseph's classic linearly interpolating ray casting algorithm is developed to this end and compared to typical alternatives. With regard to the anisotropic imaging modality required for tensor tomography, X-ray dark-field contrast is extensively reviewed. Previous literature is brought into a joint context and nomenclature and supplemented by original work completing a consistent picture of the theory of dark-field origination. Key results are explicitly validated by experimental data with a special focus on tomography as well as the properties of anisotropic fibrous scatterers. In order to address the pronounced susceptibility of interferometric images to subtle mechanical imprecisions, an efficient optimization based evaluation strategy for the raw data provided by Talbot interferometers is developed. Finally, the fitness of linear tensor models with respect to the derived anisotropy properties of dark-field contrast is evaluated, and an iterative scheme for the reconstruction of tensor valued volumes from projection images is proposed. The derived methods are efficiently implemented and applied to fiber reinforced plastic samples, imaged at the ID19 imaging beamline of the European Synchrotron Radiation Facility. The results represent unprecedented demonstrations of X-ray dark-field tensor tomography at a field of view of 3-4cm, revealing local fiber orientations of both complex shaped and low-contrast samples at a spatial resolution of 0.1mm in 3D. The results are confirmed by an independent micro CT based fiber analysis.