Refine
Has Fulltext
- yes (6)
Is part of the Bibliography
- yes (6)
Year of publication
- 2012 (6) (remove)
Document Type
- Journal article (3)
- Doctoral Thesis (3)
Keywords
- MRI (6) (remove)
Institute
Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures
(2012)
Background: One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating.
Methods: A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip. Results: A maximum temperature rise of 22.4 degrees C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2 degrees C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8 degrees C.
Conclusion: Up to a maximum of 22.4 degrees C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip system can be used to increase MR safety of EP catheters by suppressing the effects of unwanted passive catheter heating due to RF exposure from the MR scanner.
Proton magnetic resonance imaging (MRI) has recently emerged as a clinical tool to image the lungs. This paper outlines the current technical aspects of MRI pulse sequences, radiofrequency (RF) coils and MRI system requirements needed for imaging the pulmonary parenchyma and vasculature. Lung MRI techniques are presented as a “technical toolkit”, from which MR protocols will be composed in the subsequent papers for comprehensive imaging of lung disease and function (parts 2 and 3). This paper is pitched at MR scientists, technicians and radiologists who are interested in understanding and establishing lung MRI methods. Images from a 1.5 T scanner are used for illustration of the sequences and methods that are highlighted.
Main Messages
• Outline of the hardware and pulse sequence requirements for proton lung MRI
• Overview of pulse sequences for lung parenchyma, vascular and functional imaging with protons
• Demonstration of the pulse-sequence building blocks for clinical lung MRI protocols
Background
A new thromboembolic animal model showed beneficial effects of t-PA with an infarct volume reduction of 36.8% in swiss mice. Because knock-out animal experiments for stroke frequently used C57BL76 mice we evaluated t-PA effects in this mouse strain and measured infarct volume and vascular recanalisation in-vivo by using high-field 9.4 T MRI and a 1H surface cryo coil.
Methods
Clot formation was triggered by microinjection of murine thrombin into the right middle cerebral artery (MCA). Animals (n = 28) were treated with 10 mg/kg, 5 mg/kg or no tissue plasminogen activator (t-PA) 40 min after MCA occlusion. For MR-imaging a Bruker 9.4 T animal system with a 1H surface cryo probe was used and a T2-weighted RARE sequence, a diffusion weighted multishot EPI sequence and a 3D flow-compensated gradient echo TOF angiography were performed.
Results
The infarct volume in animals treated with t-PA was significantly reduced (0.67 ± 1.38 mm3 for 10 mg/kg and 10.9 ± 8.79 mm3 for 5 mg/kg vs. 19.76 ± 2.72 mm3 ; p < 0.001) compared to untreated mice. An additional group was reperfused with t-PA inside the MRI. Already ten minutes after beginning of t-PA treatment, reperfusion flow was re-established in the right MCA. However, signal intensity was lower than in the contralateral MCA. This reduction in cerebral blood flow was attenuated during the first 60 minutes after reperfusion. 24 h after MCA occlusion and reperfusion, no difference in signal intensity of the contralateral and ipsilateral MCAs was observed.
Conclusions
We confirm a t-Pa effect using this stroke model in the C57BL76 mouse strain and demonstrate a chronological sequence MRI imaging after t-PA using a 1H surface cryo coil in a 9.4 T MRI. This setting will allow testing of new thrombolytic strategies for stroke treatment in-vivo in C57BL76 knock-out mice.
Das Ziel dieser Promotion ist der Aufbau eines dreMR Setups für einen klinischen 1,5T Scanner, das die Relaxations-Dispersions-Bildgebung ermöglicht, und die anschließende Ergründung von möglichst vielen Anwendungsfeldern von dreMR. Zu der Aufgabe gehört die Bereitstellung der zugrunde liegenden Theorie, der Bau des experimentellen Setups (Offset-Spule und Stromversorgung) sowie die Programmierung der nötigen Software. Mit dem gebauten Setup konnten zwei große Anwendungsfelder — dreMR Messungen mit und ohne Kontrastmitteln — untersucht werden.
Intrazerebrale stereotaktische Eingriffe werden zu einem großen Teil ohne direkte Sichtkontrolle durchgeführt. Ein Operateur muss sich deshalb bei der räumlichen Festlegung von Strukturen und beim Anfahren dieser Strukturen auf Hilfsmittel wie stereotaktische Geräte und auf Atlanten, über welche die stereotaktischen Geräte gesteuert werden, verlassen. Trotz großer Fortschritte bei den bildgebenden Verfahren während der letzten dreißig Jahre, ist es gegenwärtig noch nicht möglich, zuverlässig alle subkortikalen Strukturen mit computertomographischen (CT) oder magnetresonanztomographischen (MRT) zu identifizieren oder begrenzen. Eine ganze Reihe zytoarchitektonischer beziehungsweise immunhistochemischer Atlanten wurde veröffentlicht. Dennoch ist es nicht gelungen, die Ergebnisse und Abbildungen dieser Atlanten mit bildgebenden Verfahren bis in die gewünschten Details zu kombinieren, um auf diese Weise das immer noch geringe Auflösungsvermögen radiologischer Methoden zu erhöhen. Deformationen bei der Gewebsentnahme des Gehirns, bei der anschließenden Einbettung, bei der alkoholischen Dehydrierung des Gewebes, Verformungen beim Schneiden und Färben der Schnitte überfordern selbst hoch komplexe mathematische Verfahren und Algorithmen beim Versuch, zytoarchitektonische und immunhistochemische Schnitte mit der gewünschten Präzision den radiologischen Ergebnissen und Bildern und damit indirekt auch den Verhältnissen in vivo anzupassen. Als Alternative verwendeten wir ungewöhnlich dicke (350 – 440 µm) Gallozyanin- (Nissl) gefärbte Serienschnitte durch die Gehirne (ZNS) von drei Personen im Alter von 56, 68 und 36 Jahren. Bei einem Fall wurde das ZNS post mortem mit einem Kernspintomographen vor der Entnahme gescannt. Die Serienschnitte durch dieses Gehirn und das eines zweiten und dritten nicht-gescannten Falles wurden mit Gallozyanin gefärbt, die zytoarchitektonischen Grenzen des Thalamuskomplexes und seiner Unterkerne wurden nach Hassler (1982) identifiziert, jede ihrer Grenzen mit dem Cursor eines Graphiktabletts umfahren und die Gestalt des Thalamuskomplexes und seiner Unterkerne mit Hilfe von Photoshop CS5® und eines computergestützten 3D-Rekonstruktionsprogramms (Amira®) dargestellt. Im Fall 3 ließen sich nach Dunkelfeldbeleuchten die Verteilung markhaltiger Fasern studieren und die zytoarchitektonischen mit myeloarchitektonischen Befunden erweitern und ergänzen. Zusätzlich konnten im Fall 1 die histologischen Serienschnitte und ihre 3D Rekonstruktion mit dem post mortem in cranio MRT registriert werden. Insgesamt kann dieser methodische Ansatz als eine robuste und relativ einfache wenn auch mit umfangreicherer manueller Tätigkeit verbundene Technik zur sehr detailreichen unverformten Korrelation zytoarchitektonischer und kernspinotomographsicher Darstellung des Thalamuskomplexus und seiner Unterkerne angesehen werden. Sie könnte als Grundlage für die Herausgabe eines multimedialen 3D stereotaktischen Atlas des menschlichen Gehirns dienen.
Die Myokardausdehnung wird als neuer Parameter der Infarktanatomie eingeführt. Dessen Entwicklung über die Zeit korreliert in hohem Maße mit der Entwicklung des enddiastolischen Volumens. Beide gemeinsam, die Myokardausdehnung und die Infarktausdehnung, bestimmen die Entwicklung des enddiastolischen Volumens im Laufe des linksventrikulären Remodellings nach Myokardinfarkt. Neben den bekannten verschiedenen Formen der Dilatation des linken Ventrikels kommt es bei zahlreichen Patienten auch zu einem Rückgang des enddiastolischen Volumens im Verlauf des Remodellings.