Background: The close monitoring of blood pressure during a caesarean section performed under central neuraxial anaesthesia should be the standard of safe anaesthesia. As classical oscillometric and invasive blood pressure measuring have intrinsic disadvantages, we investigated a novel, non-invasive technique for continuous blood pressure measuring. Methods: In this monocentric, retrospective data analysis, the reliability of continuous non-invasive blood pressure measuring using ClearSight\(^®\) (Edwards Lifesciences Corporation) is validated in 31 women undergoing central neuraxial anaesthesia for caesarean section. In addition, patients and professionals evaluated ClearSight\(^®\) through questioning. Results: 139 measurements from 11 patients were included in the final analysis. Employing Bland–Altman analyses, we identified a bias of −10.8 mmHg for systolic, of −0.45 mmHg for diastolic and of +0.68 mmHg for mean arterial blood pressure measurements. Pooling all paired measurements resulted in a Pearson correlation coefficient of 0.7 for systolic, of 0.67 for diastolic and of 0.75 for mean arterial blood pressure. Compensating the interindividual differences in linear regressions of the paired measurements provided improved correlation coefficients of 0.73 for systolic, of 0.9 for diastolic and of 0.89 for mean arterial blood pressure measurements. Discussion: Diastolic and mean arterial blood pressure are within an acceptable range of deviation from the reference method, according to the Association for the Advancement of Medical Instrumentation (AAMI) in the patient collective under study. Both patients and professionals prefer ClearSight\(^®\) to oscillometric blood pressure measurement in regard of comfort and handling.
Background: Anemia remains one of the most common comorbidities in intensive care patients worldwide. The cause of anemia is often multifactorial and triggered by underlying disease, comorbidities, and iatrogenic factors, such as diagnostic phlebotomies. As anemia is associated with a worse outcome, especially in intensive care patients, unnecessary iatrogenic blood loss must be avoided. Therefore, this scoping review addresses the amount of blood loss during routine phlebotomies in adult (>17 years) intensive care patients and whether there are factors that need to be improved in terms of patient blood management (PBM). Methods: A systematic search of the Medline Database via PubMed was conducted according to PRISMA guidelines. The reported daily blood volume for diagnostics and other relevant information from eligible studies were charted. Results: A total of 2167 studies were identified in our search, of which 38 studies met the inclusion criteria (9 interventional studies and 29 observational studies). The majority of the studies were conducted in the US (37%) and Canada (13%). An increasing interest to reduce iatrogenic blood loss has been observed since 2015. Phlebotomized blood volume per patient per day was up to 377 mL. All interventional trials showed that the use of pediatric-sized blood collection tubes can significantly reduce the daily amount of blood drawn. Conclusion: Iatrogenic blood loss for diagnostic purposes contributes significantly to the development and exacerbation of hospital-acquired anemia. Therefore, a comprehensive PBM in intensive care is urgently needed to reduce avoidable blood loss, including blood-sparing techniques, regular advanced training, and small-volume blood collection tubes.
Background: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports.
Objective: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date.
Methods: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography).
Results: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute).
Conclusions: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate.