Refine
Has Fulltext
- yes (43)
Is part of the Bibliography
- yes (43)
Year of publication
Document Type
- Journal article (41)
- Doctoral Thesis (2)
Language
- English (43) (remove)
Keywords
- glaucoma (6)
- glaucoma surgery (6)
- trabeculectomy (5)
- age-related macular degeneration (3)
- bevacizumab (3)
- trabectome (3)
- trabecular meshwork (3)
- Glaukom (2)
- ab interno trabeculectomy (2)
- association (2)
- exact matching (2)
- eyes (2)
- non-penetrating glaucoma surgery (2)
- postoperative care (2)
- retinal pigment epithelium (2)
- 5-fluorouracil (1)
- AMD (1)
- Ab Interno Trabekulektomie (1)
- Ab interno trabeculectomy (1)
- Ahmed (1)
- Alternaria (1)
- Anterior chamber perfusion model (1)
- Apoptosis (1)
- Aspergillus (1)
- Augenkrankheit (1)
- Baerveldt (1)
- Bevacizumab (1)
- Bone morphogenetic protein-2 (1)
- CYR61 (1)
- Canaloplasty (1)
- Cancer (1)
- Devic syndrome (1)
- Distal outflow trac (1)
- Draize eye test (1)
- Fluorescein angiography (1)
- Fusarium (1)
- Glaucoma (1)
- Goniotomie (1)
- Incontinentia pigmenti (1)
- MAP kinase pathway (1)
- Mechanisms (1)
- Medizin (1)
- Myelin oligodendrocyte glycoprotein antibodies (MOG-IgG) (1)
- Myofibroblast differentiation (1)
- Müller cells (1)
- NMO-IgG (1)
- Necrotizing enterocolitis (1)
- Netarsudil (1)
- Non-penetrating glaucoma surgery (1)
- OCT angiography (1)
- OECD guideline (1)
- Phacocanaloplasty (1)
- Phacotrabeculectomy (1)
- Porcine eye (1)
- Proliferation (1)
- Purpureocillium (1)
- Receptor (1)
- Retinal arterial macroaneurysms (1)
- Retinopathy (1)
- Rho-kinase inhibitor (1)
- Scedosporium (1)
- Scheimpflug (1)
- Smooth-muscle-cells (1)
- Streptomyces (1)
- TGF-beta (1)
- TGFβ signaling (1)
- Trabeculectomy (1)
- Trabekulopunktion (1)
- Tropheryma whipplei (1)
- United States (1)
- VEGF (1)
- Wegener’s granulomatosis (1)
- Whipple's disease (1)
- actin (1)
- actinomycetes (1)
- actins (1)
- adhesion (1)
- aging (1)
- alternatives (1)
- antifungal susceptibility (1)
- aquaporin-4 antibodies (AQP4-IgG) (1)
- aqueous humor outflow (1)
- beaver-dam eye (1)
- behavior (1)
- biodegradable implant (1)
- biofilms (1)
- bioreactor (1)
- bleb failure (1)
- bleb scarring (1)
- canal surgery (1)
- canaloplasty (1)
- case report (1)
- cased-control studies (1)
- cataract surgery (1)
- cell cultures (1)
- cell staining (1)
- central corneal thickness (1)
- chorioretinal lesions (1)
- ciliolenticular block glaucoma (1)
- circumferential viscodilation (1)
- collagen-glycosaminoglycane matrix (CGM) (1)
- complement factor-H (1)
- cones (1)
- conjunctival defect (1)
- conjunctival hole (1)
- conjunctival repair (1)
- contact lens (1)
- corneal endothelium (1)
- corneal epithelium (1)
- corneal equivalent (1)
- corneal storage (1)
- cyclophosphamide (1)
- cytoskeleton (1)
- drainage tube (1)
- elastic magnetic-materials (1)
- ellipsoid (1)
- endophthalmitis (1)
- episcleral drainage device (1)
- epithelial-mesenchymal transition (1)
- esohypotropia (1)
- expression (1)
- extracellular matrix (1)
- eye diseases (1)
- eye infection (1)
- eye irritation testing (1)
- ferroptosis (1)
- flexible microcatheter (1)
- fluorophores (1)
- fungal infection (1)
- genetic loci (1)
- genetics of disease (1)
- genome-wide scan (1)
- genotyping (1)
- giant cell arteritis (1)
- glaucoma drainage device (1)
- glaucoma progression (1)
- goldmann applanation tonometer (1)
- grading system (1)
- granulomatosis with polyangiitis (1)
- haze (1)
- heavy eye (1)
- hemorrhages (1)
- high myopia (1)
- histology (1)
- human genetics (1)
- human retinal pigment epithelium (1)
- hydrogels (1)
- hyperspectral autofluorescence imaging (1)
- iStent (1)
- identification (1)
- intraocular pressure (1)
- intravenous ceftriaxone (1)
- intravitreal vancomycin and amikacin (1)
- keratitis (1)
- laser suture lysis (1)
- laterality (1)
- macular degeneration (1)
- maculopathy (1)
- magnetic resonance imaging (1)
- magnetorheological elastomers (1)
- malignant glaucoma (1)
- marine sponges (1)
- matrix metalloproteases (1)
- mechanics (1)
- mechanotransduction (1)
- medicine (1)
- membrane (1)
- microbiome (1)
- microfilament (1)
- microtubules (1)
- mitomycin C (1)
- months follow-up (1)
- multifocal choroiditis (1)
- muscle dislocation (1)
- nasal mucosal barrier function (1)
- natamycin (1)
- neuro-/photoreceptor degeneration (1)
- neuromyelitis optica (1)
- neuromyelitis optica spectrum disorders (NMOSD) (1)
- nycthemeral intraocular pressure (1)
- ocular anterior segment perfusion culture (1)
- ocular infection (1)
- ologen implant (1)
- onset (1)
- open-angle glaucoma (1)
- ophthalmic artery (1)
- optic nerve (1)
- optic neuritis (1)
- optical coherence tomography (1)
- oral cefpodoxime (1)
- oral doxycycline (1)
- orbit (1)
- outer retinal tubulation (1)
- pars plana vitrectomy (1)
- patient (1)
- phacocanaloplasty (1)
- phacotrabeculectomy (1)
- photodynamic therapy (1)
- photoreceptors (1)
- pigment epithelium derived factor (1)
- population (1)
- prevalence (1)
- proteolysis (1)
- ranibizumab (1)
- releasable suture (1)
- retina (1)
- retinal neuro-axonal damage (1)
- retinal vasculitis (1)
- retinitis pigmentosa (1)
- riboflavin (1)
- right-left comparison (1)
- secondary (1)
- secondary CNV (1)
- selective retina therapy (1)
- series (1)
- smooth muscle actin (1)
- spectral characterization (1)
- spectral-domain optical coherence tomography (1)
- staphilococci (1)
- stiffness (1)
- strabismus fixus (1)
- stress fiber (1)
- surgical outcomes (1)
- susceptibility (1)
- systemic immunosuppression (1)
- tension (1)
- tight junction (1)
- tissue culture (1)
- tissue engineering (1)
- to-disc ratio (1)
- topic ofloxacin (1)
- trabecular bypass stent (1)
- trabeculopuncture (1)
- trabex+ (1)
- ultraviolet-a (1)
- variant genotypes (1)
- variants (1)
- vascular endothelial growth factor (1)
- vision (1)
- visual acuity (1)
- visual evoked potentials (1)
- vitamin C (1)
- vitrectomy (1)
Institute
- Augenklinik und Poliklinik (43) (remove)
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 311932 (1)
Purpose: To identify the underlying genetic cause in a two generation German family diagnosed with isolated aniridia.
Methods: All patients underwent full ophthalmic examination. Mutation screening of the paired box gene 6 (PAX6) was performed by bidirectional Sanger sequencing. A minigene assay was applied to analyze transcript processing of mutant and wildtype PAX6 variants in HEK293 cells.
Results: We identified a PAX6 sequence variant at the splice donor site (+5) of intron 12. This variant has been described before in another family with aniridia but has not been characterized at the transcript level. We could demonstrate that the mutant allele causes the skipping of exon 12 during transcript processing. The mutation is predicted to result in a ‘run on’ translation past the normal translational stop codon.
Conclusions: A splice site mutation resulting in exon skipping was found in a family with autosomal dominant aniridia. The mutation is predicted to result in an enlarged protein with an extra COOH-terminal domain. This very likely affects the transactivation properties of the PAX6 protein.
In the last decades significant regulatory attempts were made to replace, refine and reduce animal testing to assess the risk of consumer products for the human eye. As the original in vivo Draize eye test is criticized for limited predictivity, costs and ethical issues, several animal-free test methods have been developed to categorize substances according to the global harmonized system (GHS) for eye irritation. This review summarizes the progress of alternative test methods for the assessment of eye irritation. Based on the corneal anatomy and current knowledge of the mechanisms causing eye irritation, different ex vivo and in vitro methods will be presented and discussed with regard to possible limitations and status of regulatory acceptance. In addition to established in vitro models, this review will also highlight emerging, full thickness cornea models that might be suited to predict all GHS categories.
Abstract
Purpose: To compare ab interno trabeculectomy by trabecular meshwork excision to plasma-mediated ablation in primary open-angle glaucoma.
Methods: Retrospectively collected data of TrabEx+ (n=56) and Trabectome (n=99) were compared by coarsened exact matching to reduce confounding and matched based on baseline intraocular pressure and age. Primary outcomes were intraocular pressure and the number of glaucoma medications. Complications and the need for additional glaucoma surgery were assessed. Patients were followed for up to one year.
Results: 53 TrabEx+ could be matched to Trabectome. Baseline intraocular pressure was 16.5 ± 4.6 mmHg in both; age was 73.7 ± 8.8 years and 71.5 ± 9.9 years in TrabEx+ and Trabectome, respectively. TrabEx+ were taking more medications than Trabectome (p<0.001). Intraocular pressure was reduced to 14.8±4.3 in TrabEx+ and 13.4±3.4 in Trabectome at 6 months, and to 14.9±6.0 (p=0.13) in TrabEx+ and to 14.1±3.8 mmHg (all p<0.05) in Trabectome at 12 months. Medications were reduced at both 6 and 12 months (p< 0.05). No differences were seen between both groups at 6 and 12 months. In TrabEx+, only one serious complication occurred, and two patients required further glaucoma surgery.
Conclusion: Although both groups had a baseline intraocular pressure considered low for ab interno trabeculectomy, intraocular pressure and medications were reduced further at 6 and 12 months. Intraocular pressure reduction did not reach significance in TrabEx+ at 12 months. The inter-group comparison did not reveal any significant differences. Both had a low complication rate.
Intraocular pressure (IOP) is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4 independent population-based studies in The Netherlands. We replicated our findings in 7,482 participants from 4 additional cohorts from the UK, Australia, Canada, and the Wellcome Trust Case-Control Consortium 2/Blue Mountains Eye Study. IOP was significantly associated with rs11656696, located in GAS7 at 17p13.1 (p = 1.4 x 10\(^{-8}\)), and with rs7555523, located in TMCO1 at 1q24.1 (p = 1.6 x 10\(^{-8}\)). In a meta-analysis of 4 case-control studies (total N = 1,432 glaucoma cases), both variants also showed evidence for association with glaucoma (p = 2.4 x 10\(^{-2}\) for rs11656696 and p = 9.1 x 10\(^{-4}\) for rs7555523). GAS7 and TMCO1 are highly expressed in the ciliary body and trabecular meshwork as well as in the lamina cribrosa, optic nerve, and retina. Both genes functionally interact with known glaucoma disease genes. These data suggest that we have identified two clinically relevant genes involved in IOP regulation.
BACKGROUND: The purpose of this study was to compare the outcomes of trabeculectomy using single sutures or releasable sutures.
METHODS: This retrospective study analyzed the medical records of 61 patients who had undergone trabeculectomy using single sutures (n = 33, 54.1%) or releasable sutures (n = 28, 45.9%). The scleral flap was secured with a mean 3.9 (range 3-5) single sutures in 33 patients and with three releasable sutures in 28 patients. Primary outcomes were the success rate, based on intraocular pressure and medication usage, and the frequency of complications and post-surgical interventions. The criteria used to determine complete success were, first, intraocular pressure < 18 mmHg and, second, <=21 mmHg and >=20% intraocular pressure reduction without glaucoma medication.
RESULTS: All patients had an intraocular pressure <= 21 mmHg; 87.5% in the single suture group and 92.6% in the releasable suture group had an intraocular pressure < 18 mmHg at 24 months. There was a highly significant reduction in intraocular pressure to baseline values in both groups at the last visit. Applying the first criterion, complete success was achieved in 57.6% of patients with single sutures and 71.4% with releasable sutures, and based on the second criterion, 66.7% and 71.4%, respectively. No significant difference was found between the groups with regard to intraocular pressure, or success or complication rates.
CONCLUSION: The results of trabeculectomy using single sutures or releasable sutures are equivalent. Therefore, the choice of suture technique should be based on individual patient requirements and surgeon experience.
Purpose
To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching.
Methods
Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification.
Results
A total of 78 eyes (39 in each group) could be matched as exact pairs with a baseline IOP of 18.3 ± 5.1 mmHg and glaucoma medications of 2.7 ± 1.2 in each. IOP in IS2 was reduced to 14.6 ± 4.2 mmHg at 3 months and in T to a minimum of 13.1 ± 3.2 mmHg at 1 month. In IS2, IOP began to rise again at 6 months, eventually exceeding baseline. At 24 months, IOP in IS2 was 18.8 ± 9.0 mmHg and in T 14.2 ± 3.5 mmHg. IS2 had a higher average IOP than T at all postoperative visits (p < 0.05 at 1, 12, 18 months). Glaucoma medications decreased to 2.0 ± 1.5 in IS2 and to 1.5 ± 1.4 in T.
Conclusion
T resulted in a larger and sustained IOP reduction compared with IS2 where a rebound occurred after 6 months to slightly above preoperative values.
Background
Cataract and glaucoma are both common comorbidities among older patients. Combining glaucoma surgery with minimal invasive phacoemulsification (phaco) is a considerable option to treat both conditions at the same time, although the combination with filtration surgery can produce a strong inflammatory response. Combined non-penetrating procedures like canaloplasty have shown to reduce intraocular pressure (IOP) comparable to trabeculectomy without the risk of serious bleb-related complications. The purpose of this retrospective study was to compare the outcomes of phacotrabeculectomy and phacocanaloplasty.
Methods
Thirty-nine eyes with concomitant cataract and glaucoma who underwent phacotrabeculectomy (n = 20; 51.3%) or phacocanaloplasty (n = 19; 48.7%) were included into this trial on reduction of IOP, use of medication, success rate, incidence of complications and postsurgical interventions. Complete success was defined as IOP reduction by 30% or more and to 21 mmHg or less (definition 1a) or IOP to less than 18 mmHg (definition 2a) without glaucoma medication.
Results
Over a 12-month follow-up, baseline IOP significantly decreased from 30.0 ± 5.3 mmHg with a mean of 2.5 ± 1.2 glaucoma medications to 11.7 ± 3.5 mmHg with a mean of 0.2 ± 0.4 medications in eyes with phacotrabeculectomy (P < .0001). Eyes with phacocanaloplasty had a preoperative IOP of 28.3 ± 4.1 mmHg and were on 2.8 ± 1.1 IOP-lowering drugs. At 12 months, IOP significantly decreased to 12.6 ± 2.1 mmHg and less glaucoma medications were necessary (mean 1.0 ± 1.5 topical medications; P < .05). 15 patients (78.9%) with phacotrabeculectomy and 9 patients (60.0%) in the phacocanaloplasty group showed complete success according to definition 1 and 2 after 1 year (P = .276). Postsurgical complications were seen in 7 patients (36.8%) of the phacocanaloplasty group which included intraoperative macroperforation of the trabeculo-Descemet membrane (5.3%), hyphema (21.1%) and bleb formation (10.5%). Although more complications were observed in the phacotrabeculectomy group, no statistically significant difference was found.
Conclusions
Phacocanaloplasty offers a new alternative to phacotrabeculectomy for treatment of concomitant glaucoma and cataract, although phacotrabeculectomy yielded in better results in terms of IOP maintained without glaucoma medications.
Background:
To report the results of the repair of conjunctival erosions resulting from glaucoma drainage device surgery using collagen-glycosaminoglycane matrices (CGM).
Methods:
Case series of 8 patients who underwent revision surgery due to conjunctival defects with exposed tubes through necrosis of the overlying scleral flap and conjunctiva after Baerveldt drainage device surgery. The defects were repaired by lateral displacement of the tube towards the sclera, with a slice of a CGM as a patch, covered by adjacent conjunctiva.
Result:
Successful, lasting closure (follow-up of 12 to 42 months) of the conjunctival defects was achieved without any side-effects or complications in all eight cases.
Conclusions:
Erosion of the drainage tube, creating buttonholes in the conjunctiva after implantation of glaucoma drainage devices, is a potentially serious problem. It can be managed successfully using a biodegradable CGM as a patch.
Course of disease in multifocal choroiditis lacking sufficient immunosuppression: a case report
(2016)
Background:
Multifocal choroiditis with panuveitis is a rare disease. The educational merit of this case presentation results from the good documentation and the impressive ocular fundus pictures.
Case presentation:
We illustrate the 3-year course of disease in a 22-year-old myopic white woman with multifocal choroiditis with panuveitis and secondary choroidal neovascularization. The activity of the disease was evaluated clinically by optical coherence tomography and fluorescein angiography. Choroidal neovascularization was treated by intravitreal bevacizumab (2.5 mg/0.1 ml). Our patient lacked systemic therapy for the first 11 months because of noncompliance.
Conclusions:
The case is remarkable as the delayed onset of peripheral lesions and the additional existence of high myopia made diagnosis difficult. In addition, it demonstrates that full outbreak of disease with multiple central and peripheral fundus lesions and secondary choroidal neovascularization can develop without systemic treatment.
The functional role of the respiratory epithelium is to generate a physical barrier. In addition, the epithelium supports the innate and acquired immune system through various cytokines and chemokines. However, epithelial cells are also involved in the pathogenesis of various respiratory diseases, some of which are mediated by increased permeability of the mucosal membrane or disturbed mucociliary transport. In addition, it has been shown that epithelial cells are involved in the development of inflammatory respiratory diseases. The following review article focuses on the aspects of epithelial mis-differentiation, in particular with respect to nasal mucosal barrier function, epithelial immunogenicity, nasal epithelial-mesenchymal transition and nasal microbiome.
Transforming growth factor β (TGFβ) signaling has manifold functions such as regulation of cell growth, differentiation, migration, and apoptosis. Moreover, there is increasing evidence that it also acts in a neuroprotective manner. We recently showed that TGFβ receptor type 2 (Tgfbr2) is upregulated in retinal neurons and Müller cells during retinal degeneration. In this study we investigated if this upregulation of TGFβ signaling would have functional consequences in protecting retinal neurons. To this end, we analyzed the impact of TGFβ signaling on photoreceptor viability using mice with cell type-specific deletion of Tgfbr2 in retinal neurons and Müller cells (Tgfbr2\(_{ΔOC}\)) in combination with a genetic model of photoreceptor degeneration (VPP). We examined retinal morphology and the degree of photoreceptor degeneration, as well as alterations of the retinal transcriptome. In summary, retinal morphology was not altered due to TGFβ signaling deficiency. In contrast, VPP-induced photoreceptor degeneration was drastically exacerbated in double mutant mice (Tgfbr2\(_{ΔOC}\); VPP) by induction of pro-apoptotic genes and dysregulation of the MAP kinase pathway. Therefore, TGFβ signaling in retinal neurons and Müller cells exhibits a neuroprotective effect and might pose promising therapeutic options to attenuate photoreceptor degeneration in humans.
Purpose
To characterize the effects of netarsudil on the aqueous humor outflow tract distal to the trabecular meshwork (TM). Wehypothesized that netarsudil increases outflow facility in eyes with and without circumferential ab interno trabeculectomy (AIT)that removes the TM.
Methods
Sixty-four porcine anterior segment cultures were randomly assigned to groups with (n= 32) and without circumferential AIT (n= 32). Cultures were exposed to 0.1, 1, and 10μM netarsudil (N= 8 eyes per concentration). For each concentration,IOP and vessel diameters were compared with their respective pretreatment baselines. Outflow tract vessel diameters wereassessed by spectral-domain optical coherence tomography (SDOCT) and rendered in 4D (XYZ time series).
Results
Netarsudil at 1μM reduced IOP both in eyes with TM (−0.60 ± 0.24 mmHg,p= 0.01) and in eyes without TM (−1.79 ±0.42 mmHg,p< 0.01). At this concentration, vessels of the distal outflow tract dilated by 72%. However, at 0.1μMnetarsudilelevated IOP in eyes with TM (1.59 ± 0.36 mmHg,p< 0.001) as well as in eyes without TM (0.23 ± 0.32 mmHg,p<0.001). Vessels of the distal outflow tract constricted by 31%. Similarly, netarsudil at a concentration of 10μM elevated IOP both in eyeswith TM (1.91 ± 0.193,p< 0.001) and in eyes without TM (3.65 ± 0.86 mmHg,p< 0.001). At this concentration, outflow tractvessels constricted by 27%.
Conclusion
In the porcine anterior segment culture, the dose-dependent IOP changes caused by netarsudil matched the diameterchanges of distal outflow tract vessels. Hyper- and hypotensive properties of netarsudil persisted after TM removal
Purpose
We used exact matching for a highly balanced comparison of ab interno trabeculectomy (AIT) with the trabectome to trabeculectomy with mitomycin C (TRAB).
Methods
A total of 5485 patients who underwent AIT were exact-matched to 196 TRAB patients by baseline intraocular pressure (IOP), number of glaucoma medications, and glaucoma type. Nearest-neighbor–matching was applied to age. Success was defined as a final IOP of less than 21 mmHg, IOP reduction of at least 20% reduction from baseline, and no secondary surgical interventions. Outcomes were measured at 1, 3, 6, 12, 18, and 24 months.
Results
A total of 165 AIT could be matched to 165 TRAB. The mean baseline IOP was 22.3 ± 5.6 mmHg, and the baseline number of glaucoma medications was 2.7 ± 1.1 in both groups. At 24 months, IOP was reduced to 15.8 ± 5.2 mmHg in AIT and 12.4 ± 4.7 mmHg in TRAB. IOP was lower than baseline at all visits (p < 0.01) and lower in TRAB than AIT (p < 0.01). Glaucoma medications were reduced to 2.1 ± 1.3 in AIT and 0.2 ± 0.8 in TRAB. Compared to baseline, patients used fewer drops postoperatively (p < 0.01) and more infrequently in TRAB than in AIT (p > 0.01). Secondary surgical interventions had the highest impact on success and became necessary in 15 AIT and 59 TRAB patients. Thirty-two challenging events occurred in TRAB and none in AIT.
Conclusion
Both AIT and TRAB reduced IOP and medications. This reduction was more significant in TRAB but at the expense of four times as many secondary interventions.
Fungal eye infections can lead to loss of vision and blindness. The disease is most prevalent in the tropics, although case numbers in moderate climates are increasing as well. This study aimed to determine the dominating filamentous fungi causing eye infections in Germany and their antifungal susceptibility profiles in order to improve treatment, including cases with unidentified pathogenic fungi. As such, we studied all filamentous fungi isolated from the eye or associated materials that were sent to the NRZMyk between 2014 and 2020. All strains were molecularly identified and antifungal susceptibility testing according to the EUCAST protocol was performed for common species. In total, 242 strains of 66 species were received. Fusarium was the dominating genus, followed by Aspergillus, Purpureocillium, Alternaria, and Scedosporium. The most prevalent species in eye samples were Fusarium petroliphilum, F. keratoplasticum, and F. solani of the Fusarium solani species complex. The spectrum of species comprises less susceptible taxa for amphotericin B, natamycin, and azoles, including voriconazole. Natamycin is effective for most species but not for Aspergillus flavus or Purpureocillium spp. Some strains of F. solani show MICs higher than 16 mg/L. Our data underline the importance of species identification for correct treatment.
Purpose:
The biologic relevance of human connective tissue growth factor (hCTGF) for primary human tenon fibroblasts (HTFs) was investigated by RNA expression profiling using affymetrix (TM) oligonucleotide array technology to identify genes that are regulated by hCTGF.
Methods:
Recombinant hCTGF was expressed in HEK293T cells and purified by affinity and gel chromatography. Specificity and biologic activity of hCTGF was confirmed by biosensor interaction analysis and proliferation assays. For RNA expression profiling HTFs were stimulated with hCTGF for 48h and analyzed using affymetrix (TM) oligonucleotide array technology. Results were validated by real time RT-PCR.
Results:
hCTGF induces various groups of genes responsible for a wound healing and inflammatory response in HTFs. A new subset of CTGF inducible inflammatory genes was discovered (e.g., chemokine [C-X-C motif] ligand 1 [CXCL1], chemokine [C-X-C motif] ligand 6 [CXCL6], interleukin 6 [IL6], and interleukin 8 [IL8]). We also identified genes that can transmit the known biologic functions initiated by CTGF such as proliferation and extracellular matrix remodelling. Of special interest is a group of genes, e.g., osteoglycin (OGN) and osteomodulin (OMD), which are known to play a key role in osteoblast biology.
Conclusions:
This study specifies the important role of hCTGF for primary tenon fibroblast function. The RNA expression profile yields new insights into the relevance of hCTGF in influencing biologic processes like wound healing, inflammation, proliferation, and extracellular matrix remodelling in vitro via transcriptional regulation of specific genes. The results suggest that CTGF potentially acts as a modulating factor in inflammatory and wound healing response in fibroblasts of the human eye.
The cornea is the most-transplanted tissue worldwide. However, the availability and quality of grafts are limited due to the current methods of corneal storage. In this study, a dynamic bioreactor system is employed to enable the control of intraocular pressure and the culture at the air-liquid interface. Thereby, in vivo-like storage conditions are achieved. Different media combinations for endothelium and epithelium are tested in standard and dynamic conditions to enhance the viability of the tissue. In contrast to culture conditions used in eye banks, the combination of the bioreactor and biochrom medium 1 allows to preserve the corneal endothelium and the epithelium. Assessment of transparency, swelling, and the trans-epithelial-electrical-resistance (TEER) strengthens the impact of the in vivo-like tissue culture. For example, compared to corneas stored under static conditions, significantly lower optical densities and significantly higher TEER values were measured (p-value <0.05). Furthermore, healing of epithelial defects is enabled in the bioreactor, characterized by re-epithelialization and initiated stromal regeneration. Based on the obtained results, an easy-to-use 3D-printed bioreactor composed of only two parts was derived to translate the technology from the laboratory to the eye banks. This optimized bioreactor facilitates noninvasive microscopic monitoring. The improved storage conditions ameliorate the quality of corneal grafts and the storage time in the eye banks to increase availability and reduce re-grafting.
Purpose
To determine whether 24-h IOP monitoring can be a predictor for glaucoma progression and to analyze the inter-eye relationship of IOP, perfusion, and progression parameters.
Methods
We extracted data from manually drawn IOP curves with HIOP-Reader, a software suite we developed. The relationship between measured IOPs and mean ocular perfusion pressures (MOPP) to retinal nerve fiber layer (RNFL) thickness was analyzed. We determined the ROC curves for peak IOP (T\(_{max}\)), average IOP(T\(_{avg}\)), IOP variation (IOP\(_{var}\)), and historical IOP cut-off levels to detect glaucoma progression (rate of RNFL loss). Bivariate analysis was also conducted to check for various inter-eye relationships.
Results
Two hundred seventeen eyes were included. The average IOP was 14.8 ± 3.5 mmHg, with a 24-h variation of 5.2 ± 2.9 mmHg. A total of 52% of eyes with RNFL progression data showed disease progression. There was no significant difference in T\(_{max}\), T\(_{avg}\), and IOP\(_{var}\) between progressors and non-progressors (all p > 0.05). Except for T\(_{avg}\) and the temporal RNFL, there was no correlation between disease progression in any quadrant and T\(_{max}\), T\(_{avg}\), and IOP\(_{var}\). Twenty-four-hour and outpatient IOP variables had poor sensitivities and specificities in detecting disease progression. The correlation of inter-eye parameters was moderate; correlation with disease progression was weak.
Conclusion
In line with our previous study, IOP data obtained during a single visit (outpatient or inpatient monitoring) make for a poor diagnostic tool, no matter the method deployed. Glaucoma progression and perfusion pressure in left and right eyes correlated weakly to moderately with each other.
Key messages
What is known:
● Our prior study showed that manually obtained 24-hour inpatient IOP measurements in right eyes are poor predictors for glaucoma progression. The inter-eye relationship of 24-hour IOP parameters and disease progression on optical coherence tomography (OCT) has not been examined.
What we found:
● 24-hour IOP profiles of left eyes from the same study were a poor diagnostic tool to detect worsening glaucoma.
● Significant inter-eye correlations of various strengths were found for all tested parameters
Objective
Blindness is a feared complication of giant cell arteritis (GCA). However, the spectrum of pathologic orbital imaging findings on magnetic resonance imaging (MRI) in GCA is not well understood. In this study, we assess inflammatory changes of intraorbital structures on black blood MRI (BB-MRI) in patients with GCA compared to age-matched controls.
Methods
In this multicenter case-control study, 106 subjects underwent BB-MRI. Fifty-six patients with clinically or histologically diagnosed GCA and 50 age-matched controls without clinical or laboratory evidence of vasculitis were included. All individuals were imaged on a 3-T MR scanner with a post-contrast compressed-sensing (CS) T1-weighted sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) BB-MRI sequence. Imaging results were correlated with available clinical symptoms.
Results
Eighteen of 56 GCA patients (32%) showed inflammatory changes of at least one of the intraorbital structures. The most common finding was enhancement of at least one of the optic nerve sheaths (N = 13, 72%). Vessel wall enhancement of the ophthalmic artery was unilateral in 8 and bilateral in 3 patients. Enhancement of the optic nerve was observed in one patient. There was no significant correlation between imaging features of inflammation and clinically reported orbital symptoms (p = 0.10). None of the age-matched control patients showed any inflammatory changes of intraorbital structures.
Conclusions
BB-MRI revealed inflammatory findings in the orbits in up to 32% of patients with GCA. Optic nerve sheath enhancement was the most common intraorbital inflammatory change on BB-MRI. MRI findings were independent of clinically reported orbital symptoms.
Key Points
• Up to 32% of GCA patients shows signs of inflammation of intraorbital structures on BB-MRI.
• Enhancement of the optic nerve sheath is the most common intraorbital finding in GCA patients on BB-MRI.
• Features of inflammation of intraorbital structures are independent of clinically reported symptoms.
The aim of this review is to use the multimedia aspects
of a purely digital online publication to explain and
illustrate the highly capable technique of m-sequences in
multifocal ophthalmic electrophysiology. M-sequences
have been successfully applied in clinical routines during
the past 20 years. However, the underlying mathematical
rationale is often daunting. These mathematical
properties of m-sequences allow one not only to
separate the responses from different fields but also to
analyze adaptational effects and impacts of former
events. By explaining the history, the formation, and the
different aspects of application, a better comprehension
of the technique is intended. With this review we aim to
clarify the opportunities of m-sequences in order to
motivate scientists to use m-sequences in their future
research.
Marine sponge-derived Streptomyces sp SBT343 extract inhibits staphylococcal biofilm formation
(2017)
Staphylococcus epidermidis and Staphylococcus aureus are opportunistic pathogens that cause nosocomial and chronic biofilm-associated infections. Indwelling medical devices and contact lenses are ideal ecological niches for formation of staphylococcal biofilms. Bacteria within biofilms are known to display reduced susceptibilities to antimicrobials and are protected from the host immune system. High rates of acquired antibiotic resistances in staphylococci and other biofilm-forming bacteria further hamper treatment options and highlight the need for new anti-biofilm strategies. Here, we aimed to evaluate the potential of marine sponge-derived actinomycetes in inhibiting biofilm formation of several strains of S. epidermidis, S. aureus, and Pseudomonas aeruginosa. Results from in vitro biofilm-formation assays, as well as scanning electron and confocal microscopy, revealed that an organic extract derived from the marine sponge-associated bacterium Streptomyces sp. SBT343 significantly inhibited staphylococcal biofilm formation on polystyrene, glass and contact lens surfaces, without affecting bacterial growth. The extract also displayed similar antagonistic effects towards the biofilm formation of other S. epidermidis and S. aureus strains tested but had no inhibitory effects towards Pseudomonas biofilms. Interestingly the extract, at lower effective concentrations, did not exhibit cytotoxic effects on mouse fibroblast, macrophage and human corneal epithelial cell lines. Chemical analysis by High Resolution Fourier Transform Mass Spectrometry (HRMS) of the Streptomyces sp. SBT343 extract proportion revealed its chemical richness and complexity. Preliminary physico-chemical characterization of the extract highlighted the heat-stable and non-proteinaceous nature of the active component(s). The combined data suggest that the Streptomyces sp. SBT343 extract selectively inhibits staphylococcal biofilm formation without interfering with bacterial cell viability. Due to absence of cell toxicity, the extract might represent a good starting material to develop a future remedy to block staphylococcal biofilm formation on contact lenses and thereby to prevent intractable contact lens-mediated ocular infections.