Refine
Has Fulltext
- yes (27)
Is part of the Bibliography
- yes (27) (remove)
Document Type
- Journal article (23)
- Preprint (4)
Language
- English (27) (remove)
Keywords
- Positronen-Emissions-Tomografie (8)
- prostate cancer (8)
- theranostics (7)
- PET (5)
- PSMA (5)
- PSMA-RADS (4)
- RADS (4)
- neuroendocrine tumor (4)
- prostate-specific membrane antigen (4)
- 18F-DCFPyL (3)
Institute
- Klinik und Poliklinik für Nuklearmedizin (27)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (4)
- Medizinische Klinik und Poliklinik II (4)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (2)
- Pathologisches Institut (2)
- Urologische Klinik und Poliklinik (2)
- Comprehensive Cancer Center Mainfranken (1)
- Institut für Pharmazie und Lebensmittelchemie (1)
- Medizinische Klinik und Poliklinik I (1)
- Neurochirurgische Klinik und Poliklinik (1)
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 701983 (11)
We have recently demonstrated CXCR4 overexpression in vestibular schwannomas (VS). This study investigated the feasibility of CXCR4-directed positron emission tomography/computed tomography (PET/CT) imaging of VS using the radiolabeled chemokine ligand [\(^{68}\)Ga]Pentixafor.
Methods: 4 patients with 6 primarily diagnosed or pre-treated/observed VS were enrolled. All subjects underwent [\(^{68}\)Ga]Pentixafor PET/CT prior to surgical resection. Images were analyzed visually and semi-quantitatively for CXCR4 expression including calculation of tumor-to-background ratios (TBR). Immunohistochemistry served as standard of reference in three patients.
Results: [\(^{68}\)Ga]Pentixafor PET/CT was visually positive in all cases. SUV\(_{mean}\) and SUV\(_{max}\) were 3.0 ± 0.3 and 3.8 ± 0.4 and TBR\(_{mean}\) and TBR\(_{max}\) were 4.0 ± 1.4 and 5.0 ± 1.7, respectively. Histological analysis confirmed CXCR4 expression in tumors.
Conclusion: Non-invasive imaging of CXCR4 expression using [\(^{68}\)Ga]Pentixafor PET/CT of VS is feasible and could prove useful for in vivo assessment of CXCR4 expression.
Prostate-specific membrane antigen (PSMA)-targeted PET imaging for prostate cancer with \(^{68}\)Ga-labeled compounds has rapidly become adopted as part of routine clinical care in many parts of the world. However, recent years have witnessed the start of a shift from \(^{68}\)Ga- to \(^{18}\)F-labeled PSMA-targeted compounds. The latter imaging agents have several key advantages, which may lay the groundwork for an even more widespread adoption into the clinic. First, facilitated delivery from distant suppliers expands the availability of PET radiopharmaceuticals in smaller hospitals operating a PET center but lacking the patient volume to justify an onsite \(^{68}\)Ge/\(^{68}\)Ga generator. Thus, such an approach meets the increasing demand for PSMA-targeted PET imaging in areas with lower population density and may even lead to cost-savings compared to in-house production. Moreover, \(^{18}\)F-labeled radiotracers have a higher positron yield and lower positron energy, which in turn decreases image noise, improves contrast resolution, and maximizes the likelihood of detecting subtle lesions. In addition, the longer half-life of 110 min allows for improved delayed imaging protocols and flexibility in study design, which may further increase diagnostic accuracy. Moreover, such compounds can be distributed to sites which are not allowed to produce radiotracers on-site due to regulatory issues or to centers without access to a cyclotron. In light of these advantageous characteristics, \(^{18}\)F-labeled PSMA-targeted PET radiotracers may play an important role in both optimizing this transformative imaging modality and making it widely available. We have aimed to provide a concise overview of emerging \(^{18}\)F-labeled PSMA-targeted radiotracers undergoing active clinical development. Given the wide array of available radiotracers, comparative studies are needed to firmly establish the role of the available \(^{18}\)F-labeled compounds in the field of molecular PCa imaging, preferably in different clinical scenarios.
The use of prostate-specific membrane antigen targeted PET imaging for the evaluation of prostate cancer has increased significantly in the last couple of decades. When evaluating these imaging findings based on the PSMA reporting and data system version 1.0, which categorize lesions based on their likelihood of prostate cancer involvement, PSMA-RADS-3A lesions are commonly seen, which are indeterminate for the presence of disease. A total of 28 patients with 171 PSMA-RADS-3A lesions on \(^{18}\)F-DCFPyL PET/CT scans from June 2016 to May 2017 who had follow-up cross-sectional imaging over time were included in this study. The PSA levels of patients with PSMA-RADS-3A lesions were categorized into four groups, 0–0.2, 0.2–1, 1–2, and >2 ng/mL. The pre-operative Gleason score of these patients was categorized into two groups, Gleason score < 7 or ≥7. The median age for these patients was 72.5 years (range 59–81). The median PSA value for patients with positive lesions was significantly higher than those with negative lesions (5.8 ng/mL vs. 0.2 ng/mL, p < 0.0001). The lesion positivity rate was significantly higher in patients with PSA > 1 ng/mL (18.2% vs. 81.9%, p < 0.001). On ROC analysis, the highest classification accuracy was seen at PSA ≥ 0.6 ng/mL of 80.12% (95% CI = 73.69–86.16%), and the area under the curve was 71.32% (95% CI = 61.9–80.7%, p < 0.0001). A total of 96.4% (108/112) of patients with positive lesions and 86.4% (51/59) of patients with negative lesions had a PSMA-RADS-4/5 lymph node on the initial \(^{18}\)F-DCFPyL PET/CT scan (p = 0.02). In patients with a Gleason score ≥ 7, the presence of positive PSMA-RADS-3A lesions was higher, compared to negative PSMA-RADS-3A lesions (p = 0.049). Higher PSA levels in patients with PSMA-RADS-3A lesions can point towards the presence of true positivity. PSA levels may be considered in deciding whether to call an indeterminate lesion on PSMA PET.
Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with \(^{18}\)F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUV\(_{max}\), SUV\(_{peak}\), SUV\(_{mean}\)) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50%). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUV\(_{max}\) and SUV\(_{peak}\) compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUV\(_{max}\), p = 0.07; SUV\(_{peak}\), p = 0.08). SUV\(_{mean}\) (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in \(^{18}\)F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUV\(_{mean}\) and TL-PSMA in contrast to PSMA-TV.
In recent years, a paradigm shift from single-photon-emitting radionuclide radiotracers toward positron-emission tomography (PET) radiotracers has occurred in nuclear oncology. Although PET-based molecular imaging of the kidneys is still in its infancy, such a trend has emerged in the field of functional renal radionuclide imaging. Potentially allowing for precise and thorough evaluation of renal radiotracer urodynamics, PET radionuclide imaging has numerous advantages including precise anatomical co-registration with CT images and dynamic three-dimensional imaging capability. In addition, relative to scintigraphic approaches, PET can allow for significantly reduced scan time enabling high-throughput in a busy PET practice and further reduces radiation exposure, which may have a clinical impact in pediatric populations. In recent years, multiple renal PET radiotracers labeled with C-11, Ga-68, and F-18 have been utilized in clinical studies. Beyond providing a precise non-invasive read-out of renal function, such radiotracers may also be used to assess renal inflammation. This manuscript will provide an overview of renal molecular PET imaging and will highlight the transformation of conventional scintigraphy of the kidneys toward novel, high-resolution PET imaging for assessing renal function. In addition, future applications will be introduced, e.g. by transferring the concept of molecular image-guided diagnostics and therapy (theranostics) to the field of nephrology.
Despite histological evidence in various solid tumor entities, available experience with CXCR4-directed diagnostics and endoradiotherapy mainly focuses on hematologic diseases. With the goal of expanding the application of CXCR4 theranostics to solid tumors, we aimed to elucidate the feasibility of CXCR4-targeted imaging in a variety of such neoplasms.
Methods: Nineteen patients with newly diagnosed, treatment-naïve solid tumors including pancreatic adenocarcinoma or neuroendocrine tumor, cholangiocarcinoma, hepatocellular carcinoma, renal cell carcinoma, ovarian cancer, and prostate cancer underwent [\(^{68}\)Ga]Pentixafor PET/CT. CXCR4-mediated uptake was assessed both visually and semi-quantitatively by evaluation of maximum standardized uptake values (SUV\(_{max}\)) of both primary tumors and metastases. With physiologic liver uptake as reference, tumor-to-background ratios (TBR) were calculated. [\(^{68}\)Ga]Pentixafor findings were further compared to immunohistochemistry and [\(^{18}\)F]FDG PET/CT.
Results: On [\(^{68}\)Ga]Pentixafor PET/CT, 10/19 (52.6%) primary tumors were visually detectable with a median SUVmax of 5.4 (range, 1.7–16.0) and a median TBR of 2.6 (range, 0.8–7.4), respectively. The highest level of radiotracer uptake was identified in a patient with cholangiocarcinoma (SUVmax, 16.0; TBR, 7.4). The relatively low uptake on [\(^{68}\)Ga]Pentixafor was also noted in metastases, exhibiting a median SUVmax of 4.5 (range, 2.3–8.8; TBR, 1.7; range, 1.0–4.1). A good correlation between uptake on [\(^{68}\)Ga]Pentixafor and histological derived CXCR4 expression was noted (R = 0.62, P < 0.05). In the 3 patients in whom [\(^{18}\)F]FDG PET/CT was available, [\(^{68}\)Ga]Pentixafor exhibited lower uptake in all lesions.
Conclusions: In this cohort of newly diagnosed, treatment-naïve patients with solid malignancies, CXCR4 expression as detected by [\(^{68}\)Ga]Pentixafor-PET/CT and immunohistochemistry was rather moderate. Thus, CXCR4-directed imaging may not play a major role in the management of solid tumors in the majority of patients.
We aimed to elucidate the diagnostic potential of the C-X-C motif chemokine receptor 4 (CXCR4)-directed positron emission tomography (PET) tracer \(^{68}\)Ga-Pentixafor in patients with poorly differentiated neuroendocrine carcinomas (NEC), relative to the established reference standard \(^{18}\)F-FDG PET/computed tomography (CT). In our database, we retrospectively identified 11 treatment-naïve patients with histologically proven NEC, who underwent \(^{18}\)F-FDG and CXCR4-directed PET/CT for staging and therapy planning. The images were analyzed on a per-patient and per-lesion basis and compared to immunohistochemical staining (IHC) of CXCR4 from PET-guided biopsies. \(^{68}\)Ga-Pentixafor visualized tumor lesions in 10/11 subjects, while \(^{18}\)F-FDG revealed sites of disease in all 11 patients. Although weak to moderate CXCR4 expression could be corroborated by IHC in 10/11 cases, \(^{18}\)F-FDG PET/CT detected significantly more tumor lesions (102 vs. 42; total lesions, n = 107; p < 0.001). Semi-quantitative analysis revealed markedly higher 18F-FDG uptake as compared to \(^{68}\)Ga-Pentixafor (maximum and mean standardized uptake values (SUV) and tumor-to-background ratios (TBR) of cancerous lesions, SUVmax: 12.8 ± 9.8 vs. 5.2 ± 3.7; SUVmean: 7.4 ± 5.4 vs. 3.1 ± 3.2, p < 0.001; and, TBR 7.2 ± 7.9 vs. 3.4 ± 3.0, p < 0.001). Non-invasive imaging of CXCR4 expression in NEC is inferior to the reference standard \(^{18}\)F-FDG PET/CT.
Purpose: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET) is emerging as an important modality for imaging patients with prostate cancer (PCa). As with any imaging modality, indeterminate findings will arise. The PSMA reporting and data system (PSMA-RADS) version 1.0 codifies indeterminate soft tissue findings with the PSMA-RADS-3A moniker. We investigated the role of point-spread function (PSF) reconstructions on categorization of PSMA-RADS-3A lesions. Methods: This was a post hoc analysis of an institutional review board approved prospective trial. Around 60 min after the administration of 333 MBq (9 mCi) of PSMA-targeted \(^{18}\)F-DCFPyL, patients underwent PET/computed tomography (CT) acquisitions from the mid-thighs to the skull vertex. The PET data were reconstructed with and without PSF. Scans were categorized according to PSMA-RADS version 1.0, and all PSMA-RADS-3A lesions on non-PSF images were re-evaluated to determine if any could be re-categorized as PSMA-RADS-4. The maximum standardized uptake values (SUVs) of the lesions, mean SUVs of blood pool, and the ratios of those values were determined. Results: A total of 171 PSMA-RADS-3A lesions were identified in 30 patients for whom both PSF reconstructions and cross-sectional imaging follow-up were available. A total of 13/171 (7.6%) were re-categorized as PSMA-RADS-4 lesions with PSF reconstructions. A total of 112/171 (65.5%) were found on follow-up to be true positive for PCa, with all 13 of the re-categorized lesions being true positive on follow-up. The lesions that were re-categorized trended towards having higher SUV\(_{max}\)-lesion and SUV\(_{max}\)-lesion/SUV\(_{mean}\)-blood-pool metrics, although these relationships were not statistically significant. Conclusions: The use of PSF reconstructions for \(^{18}\)F-DCFPyL PET can allow the appropriate re-categorization of a small number of indeterminate PSMA-RADS-3A soft tissue lesions as more definitive PSMA-RADS-4 lesions. The routine use of PSF reconstructions for PSMA-targeted PET may be of value at those sites that utilize this technology.
Purpose: Prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging has become commonly utilized in patients with prostate cancer (PCa). The PSMA reporting and data system version 1.0 (PSMA-RADS version 1.0) categorizes lesions on the basis of the likelihood of PCa involvement, with PSMA-RADS-3A (soft tissue) and PSMA-RADS-3B (bone) lesions being indeterminate for the presence of disease. We retrospectively reviewed the imaging follow-up of such lesions to determine the rate at which they underwent changes suggestive of underlying PCa.
Methods: PET/CT imaging with \(^{18}\)F-DCFPyL was carried out in 110 patients with PCa and lesions were categorized according to PSMA-RADS Version 1.0. 56/110 (50.9%) patients were determined to have indeterminate PSMA-RADS-3A or PSMA-RADS-3B lesions and 22/56 (39.3%) patients had adequate follow-up to be included in the analysis. The maximum standardized uptake values (SUV\(_{max}\)) of the lesions were obtained and the ratios of SUV\(_{max}\) of the lesions to SUV\(_{mean}\) of blood pool (SUV\(_{max}\)-lesion/SUV\(_{mean}\)-bloodpool) were calculated. Pre-determined criteria were used to evaluate the PSMA-RADS-3A and PSMA-RADS-3B lesions on follow-up imaging to determine if they demonstrated evidence of underlying malignancy.
Results: A total of 46 lesions in 22 patients were considered indeterminate for PCa (i.e. PSMA-RADS-3A (32 lesions) or PSMA-RADS-3B (14 lesions)) and were evaluable on follow-up imaging. 27/46 (58.7%) lesions demonstrated changes on follow-up imaging consistent with the presence of underlying PCa at baseline. These lesions included 24/32 (75.0%) PSMA-RADS-3A lesions and 3/14 (21.4%) lesions categorized as PSMA-RADS-3B. The ranges of SUVmax and SUVmax-lesion/SUVmean-bloodpool overlapped between those lesions demonstrating changes consistent with malignancy on follow-up imaging and those lesions that remained unchanged on follow-up.
Conclusion: PSMA-RADS-3A and PSMA-RADS-3B lesions are truly indeterminate in that proportions of findings in both categories demonstrate evidence of malignancy on follow-up imaging. Overall, PSMA-RADS-3A lesions are more likely than PSMA-RADS-3B lesions to represent sites of PCa and this information should be taken into when guiding patient therapy.
Even as medical data sets become more publicly accessible, most are restricted to specific medical conditions. Thus, data collection for machine learning approaches remains challenging, and synthetic data augmentation, such as generative adversarial networks (GAN), may overcome this hurdle. In the present quality control study, deep convolutional GAN (DCGAN)-based human brain magnetic resonance (MR) images were validated by blinded radiologists. In total, 96 T1-weighted brain images from 30 healthy individuals and 33 patients with cerebrovascular accident were included. A training data set was generated from the T1-weighted images and DCGAN was applied to generate additional artificial brain images. The likelihood that images were DCGAN-created versus acquired was evaluated by 5 radiologists (2 neuroradiologists [NRs], vs 3 non-neuroradiologists [NNRs]) in a binary fashion to identify real vs created images. Images were selected randomly from the data set (variation of created images, 40%-60%). None of the investigated images was rated as unknown. Of the created images, the NRs rated 45% and 71% as real magnetic resonance imaging images (NNRs, 24%, 40%, and 44%). In contradistinction, 44% and 70% of the real images were rated as generated images by NRs (NNRs, 10%, 17%, and 27%). The accuracy for the NRs was 0.55 and 0.30 (NNRs, 0.83, 0.72, and 0.64). DCGAN-created brain MR images are similar enough to acquired MR images so as to be indistinguishable in some cases. Such an artificial intelligence algorithm may contribute to synthetic data augmentation for "data-hungry" technologies, such as supervised machine learning approaches, in various clinical applications.
(1) Background: Prostate-specific membrane antigen (PSMA)-directed radioligand therapy (RLT) has shown remarkable results in patients with advanced prostate cancer. We aimed to evaluate the toxicity profile of the PSMA ligand [\(^{177}\)Lu]Lu-PSMA I&T. (2) Methods: 49 patients with metastatic, castration-resistant prostate cancer treated with at least three cycles of [\(^{177}\)Lu]Lu-PSMA I&T were evaluated. Prior to and after RLT, we compared leukocytes, hemoglobin, platelet counts, and renal functional parameters (creatinine, eGFR, n = 49; [\(^{99m}\)Tc]-MAG3-derived tubular extraction rate (TER), n = 42). Adverse events were classified according to the Common Terminology Criteria for Adverse Events (CTCAE) v5.0 and KDIGO Society. To identify predictive factors, we used Spearman's rank correlation coefficient. (3) Results: A substantial fraction of the patients already showed impaired renal function and reduced leukocyte counts at baseline. Under RLT, 11/49 (22%) patients presented with nephrotoxicity CTCAE I or II according to creatinine, but 33/49 (67%) according to eGFR. Only 5/42 (13%) showed reduced TER, defined as <70% of the age-adjusted mean normal values. Of all renal functional parameters, absolute changes of only 2% were recorded. CTCAE-based re-categorization was infrequent, with creatinine worsening from I to II in 2/49 (4.1%; GFR, 1/49 (2%)). Similar results were recorded for KDIGO (G2 to G3a, 1/49 (2%); G3a to G3b, 2/49 (4.1%)). After three cycles, follow-up eGFR correlated negatively with age (r = −0.40, p = 0.005) and the eGFR change with Gleason score (r = −0.35, p < 0.05) at baseline. Leukocytopenia CTCAE II occurred only in 1/49 (2%) (CTCAE I, 20/49 (41%)) and CTCAE I thrombocytopenia in 7/49 (14%), with an absolute decrease of 15.2% and 16.6% for leukocyte and platelet counts. Anemia CTCAE II occurred in 10/49 (20%) (CTCAE I, 36/49 (73%)) with a decrease in hemoglobin of 4.7%. (4) Conclusions: After PSMA-targeted therapy using [\(^{177}\)Lu]Lu-PSMA I&T, no severe (CTCAE III/IV) toxicities occurred, thereby demonstrating that serious adverse renal or hematological events are unlikely to be a frequent phenomenon with this agent.
Purpose: As has been previously reported, the somatostatin receptor (SSTR) imaging agent [\(^{68}\)Ga]-labeled 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-d-Phe(1)-Tyr(3)-octreotate ([\(^{68}\)Ga]DOTATATE) demonstrates lower uptake in normal organs in patients with a high neuroendocrine tumor (NET) burden. Given the higher SSTR affinity of [\(^{68}\)Ga]DOTATATE, we aimed to quantitatively investigate the biodistribution of [\(^{68}\)Ga]-labeled 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-d-Phe(1)-Tyr(3)-octreotide ([68Ga]DOTATOC) to determine a potential correlation between uptake in normal organs and NET burden.
Procedures: Of the 44 included patients, 36/44 (82%) patients demonstrated suspicious radiotracer uptake on [\(^{68}\)Ga]DOTATOC positron emission tomography (PET)/x-ray computed tomography (CT). Volumes of Interest (VOIs) were defined for tumor lesions and normal organs (spleen, liver, kidneys, adrenals). Mean body weight corrected standardized uptake value (SUV\(_{mean}\)) for normal organs was assessed and was used to calculate the corresponding mean specific activity uptake (Upt: fraction of injected activity per kg of tissue). For the entire tumor burden, SUV\(_{mean}\), maximum standardized uptake value (SUV\(_{max}\)), and the total mass (TBM) was calculated and the decay corrected tumor fractional uptake (TBU) was assessed. A Spearman’s rank correlation coefficient was used to determine the correlations between normal organ uptake and tumor burden.
Results: The median SUV\(_{mean}\) was 18.7 for the spleen (kidneys, 9.2; adrenals, 6.8; liver, 5.6). For tumor burden, the median values were SUV\(_{mean}\) 6.9, SUV\(_{max}\) 35.5, TBM 42.6g, and TBU 1.2%. With increasing volume of distribution, represented by lean body mass and body surface area (BSA), Upt decreased in kidneys, liver, and adrenal glands and SUV\(_{mean}\) increased in the spleen. Correlation improved only for both kidneys and adrenals when the influence of the tumor uptake on the activity available for organ uptake was taken into account by the factor 1/(1-TBU). TBU was neither predictive for SUV\(_{mean}\) nor for Upt in any of the organs. The distribution of organ Upt vs. BSA/(1-TBU) were not different for patients with minor TBU (<3%) vs. higher TBU (>7%), indicating that the correlations observed in the present study are explainable by the body size effect. High tumor mass and uptake mitigated against G1 NET.
Conclusions: There is no significant impact on normal organ biodistribution with increasing tumor burden on [\(^{68}\)Ga]DOTATOC PET/CT. Potential implications include increased normal organ dose with [\(^{177}\)Lu-DOTA]\(^0\)-D-Phe\(^1\)-Tyr\(^3\)-Octreotide and decreased absolute lesion detection with [\(^{68}\)Ga]DOTATOC in high NET burden.
Background. Mediating glucose absorption in the small intestine and renal clearance, sodium glucose cotransporters (SGLTs) have emerged as an attractive therapeutic target in diabetic patients. A substantial fraction of patients, however, only achieve inadequate glycemic control. Thus, we aimed to assess the potential of the SGLT-targeting PET radiotracer alpha-methyl-4-deoxy-4-[\(^{18}\)F]fluoro-D-glucopyranoside ([\(^{18}\)F]Me4FDG) as a noninvasive intestinal and renal biomarker of SGLT-mediated glucose transport. Methods. We investigated healthy rats using a dedicated small animal PET system. Dynamic imaging was conducted after administration of the reference radiotracer 2-deoxy-2-[\(^{18}\)F]fluoro-D-glucose ([\(^{18}\)F]FDG), or the SGLT-targeting agent, [\(^{18}\)F]Me4FDG either directly into the digestive tract (for assessing intestinal absorption) or via the tail vein (for evaluating kidney excretion). To confirm the specificity of [18F]Me4FDG and responsiveness to treatment, a subset of animals was also pretreated with the SGLT inhibitor phlorizin. In this regard, an intraintestinal route of administration was used to assess tracer absorption in the digestive tract, while for renal assessment, phlorizin was injected intravenously (IV). Results. Serving as reference, intestinal administration of [\(^{18}\)F]FDG led to slow absorption with retention of % of administered radioactivity at 15 min. [\(^{18}\)F]Me4FDG, however, was rapidly absorbed into the blood and cleared from the intestine within 15 min, leading to markedly lower tracer retention of % (). Intraintestinal phlorizin led to marked increase of [\(^{18}\)F]Me4FDG uptake (15 min, %; vs. untreated controls), supporting the notion that this PET agent can measure adequate SGLT inhibition in the digestive tract. In the kidneys, radiotracer was also sensitive to SGLT inhibition. After IV injection, [\(^{18}\)F]Me4FDG reabsorption in the renal cortex was significantly suppressed by phlorizin when compared to untreated animals (%ID/g at 60 min, vs. untreated controls, ; ). Conclusion. As a noninvasive read-out of the concurrent SGLT expression in both the digestive tract and the renal cortex, [\(^{18}\)F]Me4FDG PET may serve as a surrogate marker for treatment response to SGLT inhibition. As such, [\(^{18}\)F]Me4FDG may enable improvement in glycemic control in diabetes by PET-based monitoring strategies.
Objectives: Recently, the standardized reporting and data system for prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging studies, termed PSMA-RADS version 1.0, was introduced. We aimed to determine the interobserver agreement for applying PSMA-RADS to imaging interpretation of 18F-DCFPyL PET examinations in a prospective setting mimicking the typical clinical work-flow at a prostate cancer referral center.
Methods: Four readers (two experienced readers (ER, > 3 years of PSMA-targeted PET interpretation experience) and two inexperienced readers (IR, < 1 year of experience)), who had all read the initial publication on PSMA-RADS 1.0, assessed 50 18F-DCFPyL PET/computed tomography (CT) studies independently. Per scan, a maximum of 5 target lesions were selected by the observers and a PSMA-RADS score for every target lesion was recorded. No specific pre-existing conditions were placed on the selection of the target lesions, although PSMA-RADS 1.0 suggests that readers focus on the most highly avid or largest lesions. An overall scan impression based on PSMA-RADS was indicated and interobserver agreement rates on a target lesion-based, on an organ-based, and on an overall PSMA-RADS score-based level were computed.
Results: The number of target lesions identified by each observer were as follows: ER 1, 123; ER 2, 134; IR 1, 123; and IR 2, 120. Among those selected target lesions, 125 were chosen by at least two individual observers (all four readers selected the same target lesion in 58/125 (46.4%) instances, three readers in 40/125 (32%) and two observers in 27/125 (21.6%) instances). The interobserver agreement for PSMA-RADS scoring among identical target lesions was good (intraclass correlation coefficient (ICC) for four, three and two identical target lesions, ≥0.60, respectively). For lymph nodes, an excellent interobserver agreement was derived (ICC=0.79). The interobserver agreement for an overall scan impression based on PSMA-RADS was also excellent (ICC=0.84), with a significant difference for ER (ICC=0.97) vs. IR (ICC=0.74, P=0.005).
Conclusions: PSMA-RADS demonstrates a high concordance rate in this study, even among readers with different levels of experience. This suggests that PSMA-RADS can be effectively used for communication with clinicians and can be implemented in the collection of data for large prospective trials.
Both prostate-specific membrane antigen (PSMA)- and somatostatin receptor (SSTR)-targeted positron emission tomography (PET) imaging agents for staging and restaging of prostate carcinoma or neuroendocrine tumors, respectively, are seeing rapidly expanding use. In addition to diagnostic applications, both classes of radiotracers can be used to triage patients for theranostic endoradiotherapy. While interpreting PSMA- or SSTR-targeted PET/computed tomography (CT) scans, the reader has to be aware of certain pitfalls. Adding to the complexity of the interpretation of those imaging agents, both normal biodistribution, and also false-positive and -negative findings differ between PSMA- and SSTR-targeted PET radiotracers. Herein summarized under the umbrella term molecular imaging reporting and data systems (MI-RADS), two novel RADS classifications for PSMA- and SSTR-targeted PET imaging are described (PSMA- and SSTR-RADS). Both framework systems may contribute to increase the level of a reader’s confidence and to navigate the imaging interpreter through indeterminate lesions, so that appropriate workup for equivocal findings can be pursued. Notably, PSMA- and SSTR-RADS are structured in a reciprocal fashion, i.e. if the reader is familiar with one system, the other system can readily be applied as well. In the present review we will discuss the most common pitfalls on PSMA- and SSTR-targeted PET/CT, briefly introduce PSMA- and SSTR-RADS, and define a future role of the umbrella framework MI-RADS compared to other harmonization systems.
Background: Radiolabeled agents that are substrates for the norepinephrine transporter (NET) can be used to quantify cardiac sympathetic nervous conditions and have been demonstrated to identify high-risk congestive heart failure (HF) patients prone to arrhythmic events. We aimed to fully characterize the kinetic profile of the novel \(^{18}\)F-labeled NET probe AF78 for PET imaging of the cardiac sympathetic nervous system (SNS) among various species.
Methods: \(^{18}\)F-AF78 was compared to norepinephrine (NE) and established SNS radiotracers by employing in vitro cell assays, followed by an in vivo PET imaging approach with healthy rats, rabbits and nonhuman primates (NHPs). Additionally, chase protocols were performed in NHPs with NET inhibitor desipramine (DMI) and the NE releasing stimulator tyramine (TYR) to investigate retention kinetics in cardiac SNS.
Results: Relative to other SNS radiotracers, 18F-AF78 showed higher transport affinity via NET in a cell-based competitive uptake assay (IC\(^{50}\) 0.42 ± 0.14 µM), almost identical to that of NE (IC\(^{50}\), 0.50 ± 0.16 µM, n.s.). In rabbits and NHPs, initial cardiac uptake was significantly reduced by NET inhibition. Furthermore, cardiac tracer retention was not affected by a DMI chase protocol but was markedly reduced by intermittent TYR chase, thereby suggesting that \(^{18}\)F-AF78 is stored and can be released via the synaptic vesicular turnover process. Computational modeling hypothesized the formation of a T-shaped π-π stacking at the binding site, suggesting a rationale for the high affinity of \(^{18}\)F-AF78.
Conclusion: \(^{18}\)F-AF78 demonstrated high in vitro NET affinity and advantageous in vivo radiotracer kinetics across various species, indicating that \(^{18}\)F-AF78 is an SNS imaging agent with strong potential to guide specific interventions in cardiovascular medicine.
The novel PET probe 2-deoxy-2-18F-fluoro-D-sorbitol (18F-FDS) has demonstrated favorable renal kinetics in animals. We aimed to elucidate its imaging properties in two human volunteers. 18F-FDS was produced by a simple one-step reduction from 18F-FDG. On dynamic renal PET, the cortex was delineated and activity gradually transited in the parenchyma, followed by radiotracer excretion. No adverse effects were reported. Given the higher spatiotemporal resolution of PET relative to conventional scintigraphy, 18F-FDS PET offers a more thorough evaluation of human renal kinetics. Due to its simple production from 18F-FDG, 18F-FDS is virtually available at any PET facility with radiochemistry infrastructure.