Refine
Has Fulltext
- yes (360)
Is part of the Bibliography
- yes (360)
Year of publication
Document Type
- Journal article (360) (remove)
Language
- English (360) (remove)
Keywords
- Hadron-Hadron scattering (experiments) (28)
- Parton Distributions (25)
- ATLAS detector (18)
- Decay (15)
- proton-proton collision (15)
- Extension (14)
- physics (14)
- Higgs boson (13)
- ++ (11)
- Physics (11)
Institute
- Physikalisches Institut (360) (remove)
Sonstige beteiligte Institutionen
- Wilhelm-Conrad-Röntgen-Forschungszentrum für komplexe Materialsysteme (4)
- Röntgen Center for Complex Material Systems (RCCM), Am Hubland, 97074 W¨urzburg, Germany (2)
- Arizona State University, Tempe, Arizona, USA (1)
- Bavarian Center for Applied Energy Research (ZAE Bayern), 97074 Würzburg, Germany (1)
- Bavarian Center for Applied Energy Research e.V. (ZAE Bayern) (1)
- Fraunhofer-Institute for Applied Optics and Precision Engineering IOF Jena, Germany (1)
- Friedrich Schiller University Jena, Germany (1)
- Genelux Corporation, San Diego Science Center, 3030 Bunker Hill Street, Suite 310, San Diego, California 92109, USA (1)
- MRB Forschungszentrum für Magnet-Resonanz-Bayern e.V., Am Hubland, D-97074 Würzburg (1)
- Max Planck School of Photonics Jena, Germany (1)
Background: During the last years, 19F-MRI and perfluorocarbon nanoemulsion (PFC) emerged as a powerful contrast agent based MRI methodology to track cells and to visualize inflammation. We applied this new modality to visualize deep tissue abscesses during acute and chronic phase of inflammation caused by Staphylococcus aureus infection. Methodology and Principal Findings: In this study, a murine thigh infection model was used to induce abscess formation and PFC or CLIO (cross linked ironoxides) was administered during acute or chronic phase of inflammation. 24 h after inoculation, the contrast agent accumulation was imaged at the site of infection by MRI. Measurements revealed a strong accumulation of PFC at the abscess rim at acute and chronic phase of infection. The pattern was similar to CLIO accumulation at chronic phase and formed a hollow sphere around the edema area. Histology revealed strong influx of neutrophils at the site of infection and to a smaller extend macrophages during acute phase and strong influx of macrophages at chronic phase of inflammation. Conclusion and Significance: We introduce 19F-MRI in combination with PFC nanoemulsions as a new platform to visualize abscess formation in a murine thigh infection model of S. aureus. The possibility to track immune cells in vivo by this modality offers new opportunities to investigate host immune response, the efficacy of antibacterial therapies and the influence of virulence factors for pathogenesis.
Using k · p theory, we derive an effective four-band model describing the physics of the typical two-dimensional topological insulator (HgTe/CdTe quantum well (QW)) in the presence of an out-of-plane (in the z-direction) inversion breaking potential and an in-plane potential. We find that up to third order in perturbation theory, only the inversion breaking potential generates new elements to the four-band Hamiltonian that are off-diagonal in spin space. When this new effective Hamiltonian is folded into an effective twoband model for the conduction (electron) or valence (heavy hole) bands, two competing terms appear: (i) a Rashba spin–orbit interaction originating from inversion breaking potential in the z-direction and (ii) an in-plane Pauli term as a consequence of the in-plane potential. Spin transport in the conduction band is further analysed within the Landauer–Büttiker formalism. We find that for asymmetrically doped HgTe QWs, the behaviour of the spin-Hall conductance is dominated by the Rashba term.
Background: Transgenic mouse models are increasingly used to study the pathophysiology of human cardiovascular diseases. The aortic pulse wave velocity (PWV) is an indirect measure for vascular stiffness and a marker for cardiovascular risk. Results: This study presents a cardiovascular magnetic resonance (CMR) transit time (TT) method that allows the determination of the PWV in the descending murine aorta by analyzing blood flow waveforms. Systolic flow pulses were recorded with a temporal resolution of 1 ms applying phase velocity encoding. In a first step, the CMR method was validated by pressure waveform measurements on a pulsatile elastic vessel phantom. In a second step, the CMR method was applied to measure PWVs in a group of five eight-month-old apolipoprotein E deficient (ApoE(-/-)) mice and an age matched group of four C57Bl/6J mice. The ApoE(-/-) group had a higher mean PWV (PWV = 3.0 ± 0.6 m/s) than the C57Bl/6J group (PWV = 2.4 ± 0.4 m/s). The difference was statistically significant (p = 0.014). Conclusions: The findings of this study demonstrate that high field CMR is applicable to non-invasively determine and distinguish PWVs in the arterial system of healthy and diseased groups of mice.
Understanding a complex network’s structure holds the key to understanding its function. The physics community has contributed a multitude of methods and analyses to this cross-disciplinary endeavor. Structural features exist on both the microscopic level, resulting from differences between single node properties, and the mesoscopic level resulting from properties shared by groups of nodes. Disentangling the determinants of network structure on these different scales has remained a major, and so far unsolved, challenge. Here we show how multiscale generative probabilistic exponential random graph models combined with efficient, distributive message-passing inference techniques can be used to achieve this separation of scales, leading to improved detection accuracy of latent classes as demonstrated on benchmark problems. It sheds new light on the statistical significance of motif-distributions in neural networks and improves the link-prediction accuracy as exemplified for gene-disease associations in the highly consequential Online Mendelian Inheritance in Man database.
The molecular beam epitaxially growth of (001) Hg\(_{1-x}\) Cd\(_z\) Te-HgTe superlattices has been systematically investigated. The well width as well as the period were determined directly by X-ray diffraction. This was accomphshed for the well width by exploiting the high reflectivity from HgTe and the low reflectivity from CdTe for the (002) Bragg reflection. Knowing the well and barrier thicknesses we have been able to set an upper limit on the aver~ge composition of the barriers, Xl, by annealing the superlattice and then measuring the composition of the. resultmg alloy. Xb was shown to decrease exponentially with decreasing barrier width. Xb is appreciably smaller m. narrow barriers due to the increased significance of interdiffusion in the Hg\(_{1-x}\)Cd\(_x\) Te/HgTe interface in narrow barriers. The experimentally determined optical absorption coefficient for these superlattices is compared WIth theoretical calculations. The absorption coefficient was determined from transmission and reflection spectra at 300, 77 and 5 K. Using the thickness and composition of the barriers and wells, and an interface width due to interdiffusion, the complex refractive index is calculated and compared with the experimental absorption coefficient. The envelope function method based on an 8 x 8 second order k . p band model was used to calculate the superlattice states. These results when inserted into Kubo's formula, yield the dynamic conductivity for interband transitions. The experimental and theoretical values for the absorption coefficient using no adjustable parameters are in good agreement for most of the investigated superlattices. Furthermore the agreement for the higher energetic interband transitions is much worse if values for the barrier composition, which are appreciably different than the experimentally determined values, are used. The infrared photoluminescence was investigated at temperatures from 4.2 to 300 K. Pronounced photoluminescence was observed for all superlattices in this temperature range.
In this paper, we present results on the first MBE growth of HgSe. The influence of the GaAs substrate temperature as well as the Hg and Se fluxes on the growth and the electrical properties has been investigated. It has been found that the growth rate is very low at substrate temperatures above 120°C. At 120°C and at lower temperatures, the growth rate is appreciably higher. The sticking coefficient of Se seems to depend inversely on the Hg/Se flux ratio. Epitaxial growth could be maintained at 70°C with Hg/Se flux ratios between lOO and ISO, and at 160°C between 280 and 450. The electron mobilities of these HgSe epilayers at room temperature decrease from a maximum value of 8.2 x 10^3 cm2 /V' s with increasing electron concentration. The concentration was found to be between 6xlO^17 and 1.6x10^19 cm- 3 at room temperature. Rocking curves from X-ray diffraction measurements of the better epilayers have a full width at half maximum of 5S0 arc sec.
We report the contactless determination of the conductivity, the mobility and the carrier concentration of II-VI semiconductors by means of the technique of the partially filled waveguide at a microwave frequency of 9 GHz. The samples are CdHgTe epitaxial layers, grown on CdZnTe substrates by molecular beam epitaxy. The conductivity is determined from the transmission coefficient of the sample in the partially filled waveguide. For the analysis of the experimental data, the complex transmission coefficient is calculated by a rigorous multi-mode matching procedure. By varying the conductivity of the sample, we obtain an optimum fit of the calculated data to the experimental results. Comparison with conductivity data determined by the van der Pauw method shows that our method allows to measure the conductivity with good accuracy. The behaviour of the transmission coefficient of the sample is discussed in dependence on the layer conductivity, the layer thickness and the dielectric constant of the substrate. The calculations require to consider in detail the distribution of the electromagnetic fields in the sample region. The usual assumption of a hardly disturbed TE\(_{10}\) mode cannot be used in our case. By applying a magnetic field in extraordinary Voigt configuration. galvanomagnetic measurements have been carried out which yield the mobility and thus the carrier concentration. These results are also in good agreement with van der Pauw transport measurements.
The surface sublimation of Cd and Te atoms from the zinc blende (111)A CdTe surface has been investigated in detail by reflection high energy electron diffraction and x-ray photoelectron spectroscopy. These experiments verify that Te is much easier to evaporate than Cd. The experimental value for the Te activation energy from a Te stabilized (111)A CdTe surface is 1.41 ±0.1O eV, which is apparently inconsistent with recent theoretical results.
The influence of different CdZnTe substrate treatments prior to II-VI molecular beam epitaxial growth on surface stoichiometry, oxygen, and carbon contamination has been studied using x-ray photoelectron spectroscopy and reflection high energy electron diffraction. Heating the substrate at 300 °C can eliminate oxygen contamination, but cannot completely remove carbon from the surface. Heating at higher temperatures decreases the carbon contamination only slightly, while increasing the Zn-Cd ratio on the surface considerably. The magnitude of the latter effect is surprising and is crucial when one is using lattice matched CdZnTe (Zn 4%) substrates.
We report here that reconstruction on (100), (1lIlA, and (1l1lB CdTe surfaces is either C(2X2), (2X2), and (l X I) or (2X I), (l X I), and (l X I) when they are Cd or Te stabilized, respectively. There is a mixed region between Cd and Te stabilization in which the reflected high-energy electron-diffraction (RHEED) patterns contain characteristics of both Cd- and Te-stabilized surfaces. We have also found that the Cd-to-Te ratio of the x-ray photoelectron intensities of their 3d\(_{3/ 2}\) core levels is about 20% larger for a Cd-stabilized (1lIlA, (1lIlB, or (100) CdTe surface than for a Te-stabilized one. According to a simple model calculation, which was normalized by means of the photoelectron intensity ratio of a Cd-stabilized (lll)A and aTe-stabilized (1l1lB CdTe surface, the experimental data for CdTe surfaces can be explained by a linear dependence of the photoelectron-intensity ratio on the fraction of Cd in the uppermost monatomic layer. This surface composition can be correlated with the surface structure, i.e., the corresponding RHEED patterns. This correlation can in turn be employed to determine Te and Cd evaporation rates. The Te reevaporation rate is increasingly slower for the Te-stabilized (Ill) A, (l1l)B, and (100) surfaces, while the opposite is true for Cd from Cd-stabilized (Ill) A and (Ill)B surfaces. In addition, Te is much more easily evaporated from all the investigated surfaces than is Cd, if the substrate is kept at normal molecular-beam-epitaxy growth temperatures ranging from 2oo·C to 300 ·C.
Infrared photoconductor fabricated with HgTe/CdTe superlattice grown by molecular beam epitaxy
(1993)
An infrared photoconductor fabricated with a HgTe/CdTe superlattice grown on a GaAs substrate by molecular beam epitaxy is described here for the first time. The growth procedure, device fabrication, and measurement results are described. The results show that the device has relatively high uniformity and 1000 K black-body detectivity 2.4 X 10\(^9\) cm Hz\(^{1/2}\) W\(^{-1}\) . The photoconductivity decay method was used for determining carrier lifetime of the HgTe/CdTe superlattice, the measured lifetime is 12\(\mu\)s at 77 K, which is the longest lifetime ever reported for HgTe/CdTe superlattices and we believe that the increase of lifetime is mainly due to the reduction of dimensions.
Molecular beam epitaxially grown short period (001) Hg\(_{1_x}\)Cd\(_x\)Te-HgTe superlattices have been systematically investigated. Several narrow well widths were chosen, e.g., 30, 35 and 40 Å, and the barrier widths were varied between 24 and 90 Å for a particular well width. Both the well width and the total period were determined directly by means of x-ray diffraction. The well width was determined by exploiting the high reflectivity from HgTe and the low reflectivity from CdTe for the (002) Bragg reflection. Knowing the well and barrier widths we have been able to set an upper limit on the average Cd concentration of the barriers, \(\overline x_b\), by annealing several superlattices and then measuring the composition of the resulting alloy. \(\overline x_b\) was shown to decrease exponentially with decreasing barrier width. The structure of a very short period superlattice, i.e., 31.4 Å, was also investigated by transmission electron microscopy, corroborating the x-ray diffraction results.
We have investigated oxygen on CdTe substrates by means of x-ray photoelectron spectroscopy (XPS) and reflection high-energy electron diffraction (RHEED). A Te oxide layer that was at least 15 A thick was found on the surface of as-delivered CdTe substrates that were mechanically polished. This oxide is not easily evaporated at temperatures lower than 350°C. Furthermore, heating in air, which further oxidizes the CdTe layer, should be avoided. Etching with HCI acid (15% HCl) for at least 20 s and then rinsing with de-ionized water reduces the Te oxide layer on the surface down to 4% of a monoatomic layer. However, according to XPS measurements of the 0 Is peak, 20%-30% of a monoatomic layer of oxygen remains on the surface, which can be eliminated by heating at temperatures ranging between 300 and 340 cC. The RHEED patterns for a molecular beam epitaxially (MBE)-grown CdTe film on a (lOO) CdTe substrate with approximately one monoatomic layer of oxidized Te on the surface lose the characteristics of the normal RHEED pattems for a MBE-grown CdTe film on an oxygen-free CdTe substrate.
We have grown HgTe/CdTe superlattices by molecular beam epitaxy; barrier thicknesses were in the range from 15 to 91 Å and the well thickness was maintained at a constant value of 30 Å. The infrared photoluminescence was investigated by means of Fourier transform infrared spectroscopy in the temperature range from 4.2 to 300 K. All superlattices showed pronounced photoluminescence at temperatures up to 300 K. To gain more detailed insight into the band structure of the HgTe/CdTe superlattices, band structure calculations were performed. The concept of the envelope function approximation was followed. Employing the transfer matrix method, the calculations were completed taking into account an eight band k·p model. An important parameter in these calculations is the natural valence band offset (VBO) between the well and barrier materials. As a general trend, the value for the direct gap decreases with increasing VBO. The experimentally determined energies of the band gap are in reasonable agreement with the values obtained by the theoretical calculations. A comparison between theory and experiment shows that the observed transition energies are closer to calculations employing a large offset (350 meV) as opposed to a small VBO (40 meV).
A semiempirical model is presented that correlates the broadening of the absorption edge with both transitions below the energy gap and with transitions by the Kane band model. This model correctly fits both the absorption and luminescence spectra of narrow-gap (Hg,Cd)Te samples that have been grown by the traveling heater method as well as by molecular-beam epitaxy. The accuracy of the band-gap determination is enhanced by this model.