Refine
Has Fulltext
- yes (1145)
Year of publication
- 2021 (1145) (remove)
Document Type
- Journal article (893)
- Doctoral Thesis (223)
- Conference Proceeding (8)
- Working Paper (6)
- Other (5)
- Book (3)
- Preprint (3)
- Master Thesis (2)
- Bachelor Thesis (1)
- Report (1)
Language
- English (1145) (remove)
Keywords
- COVID-19 (20)
- inflammation (17)
- virtual reality (14)
- SARS-CoV-2 (11)
- boron (11)
- inorganic chemistry (11)
- cancer (8)
- immunohistochemistry (8)
- Parkinson's disease (7)
- RNA (7)
Institute
- Theodor-Boveri-Institut für Biowissenschaften (168)
- Graduate School of Life Sciences (97)
- Institut für Anorganische Chemie (60)
- Institut für Psychologie (54)
- Medizinische Klinik und Poliklinik I (54)
- Institut für Informatik (48)
- Institut für Organische Chemie (46)
- Medizinische Klinik und Poliklinik II (46)
- Institut für Geographie und Geologie (43)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (39)
Sonstige beteiligte Institutionen
- Cologne Game Lab (3)
- Open University of the Netherlands (2)
- Ökologische Station Fabrikschleichach (2)
- Airbus Defence and Space GmbH (1)
- Apotheke, Universitätsklinikum Würzburg (1)
- Biomedical Center Munich, Department of Physiological Chemistry, Ludwig-Maximilians-Universität München (1)
- Birmingham City University (1)
- Bundeswehr Institute of Radiobiology affiliated to the University of Ulm, Munich, Germany (1)
- Clinical Trial Center (CTC) / Zentrale für Klinische Studien Würzburg (ZKSW) (1)
- DFG Forschungsgruppe 2757 / Lokale Selbstregelungen im Kontext schwacher Staatlichkeit in Antike und Moderne (LoSAM) (1)
Fluorescence microscopy is a form of light microscopy that has developed during the 20th century and is nowadays a standard tool in Molecular and Cell biology for studying the structure and function of biological molecules. High-resolution fluorescence microscopy techniques, such as dSTORM (direct Stochastic Optical Reconstruction Microscopy) allow the visualization of cellular structures at the nanometre scale (10−9 m). This has already made it possible to decipher the composition and function of various biopolymers, such as proteins, lipids and nucleic acids, up to the three-dimensional (3D) structure of entire organelles. In practice, however, it has been shown that these imaging methods and their further developments still face great challenges in order to achieve an effective resolution below ∼ 10 nm. This is mainly due to the nature of labelling biomolecules. For the detection of molecular structures, immunostaining is often performed as a standard method. Antibodies to which fluorescent molecules are coupled, recognize and bind specifcally and with high affnity to the molecular section of the target structure, also called epitope or antigen. The fluorescent molecules serve as reporter molecules which are imaged with the use of a fluorescence microscope. However, the size of these labels with a length of about 10-15 nm in the case of immunoglobulin G (IgG) antibodies, cause a detection of the fluorescent molecules shifted to the real position of the studied antigen. In dense regions where epitopes are located close to each other, steric hindrance between antibodies can also occur and leads to an insuffcient label density. Together with the shifted detection of fluorescent molecules, these factors can limit the achievable resolution of a microscopy technique. Expansion microscopy (ExM) is a recently developed technique that achieves a resolution improvement by physical expansion of an investigated object. Therefore, biological samples such as cultured cells, tissue sections, whole organs or isolated organelles are chemically anchored into a swellable polymer. By absorbing water, this so-called superabsorber increases its own volume and pulls the covalently bound biomolecules isotropically apart. Routinely, this method achieves a magnifcation of the sample by about four times its volume. But protocol variants have already been developed that result in higher expansion factors of up to 50-fold. Since the ExM technique includes in the frst instance only the sample treatment for anchoring and magnifcation of the sample, it can be combined with various standard methods of fluorescence microscopy. In theory, the resolution of the used imaging technique improves linearly with the expansion factor of the ExM treated sample. However, an insuffcient label density and the size of the antibodies can here again impair the effective achievable resolution. The combination of ExM with high-resolution fluorescence microscopy methods represents a promising strategy to increase the resolution of light microscopy. In this thesis, I will present several ExM variants I developed which show the combination of ExM with confocal microscopy, SIM (Structured Illumination Microscopy), STED (STimulated Emission Depletion) and dSTORM. I optimized existing ExM protocols and developed different expansion strategies, which allow the combination with the respective imaging technique. Thereby, I gained new structural insights of isolated centrioles from the green algae Chlamydomonas reinhardtii by combining ExM with STED and confocal microscopy. In another project, I combined 3D-SIM imaging with ExM and investigated the molecular structure of the so-called synaptonemal complex. This structure is formed during meiosis in eukaryotic cells and contributes to the exchange of genetic material between homologous chromosomes. Especially in combination with dSTORM, the ExM method showed its high potential to overcome the limitations of modern fluorescence microscopy techniques. In this project, I expanded microtubules in mammalian cells, a polymer of the cytoskeleton as well as isolated centrioles from C. reinhardtii. By labelling after expansion of the samples, I was able to signifcantly reduce the linkage error of the label and achieve an improved label density. In future, these advantages together with the single molecule sensitivity and high resolution obtained by the dSTORM method could pave the way for achieving molecular resolution in fluorescence microscopy
A single, specific, sensitive biochemical biomarker that can reliably diagnose a traumatic brain injury (TBI) has not yet been found, but combining different biomarkers would be the most promising approach in clinical and postmortem settings. In addition, identifying new biomarkers and developing laboratory tests can be time-consuming and economically challenging. As such, it would be efficient to use established clinical diagnostic assays for postmortem biochemistry. In this study, postmortem cerebrospinal fluid samples from 45 lethal TBI cases and 47 controls were analyzed using commercially available blood-validated assays for creatine kinase (CK) activity and its heart-type isoenzyme (CK–MB). TBI cases with a survival time of up to two hours showed an increase in both CK and CK–MB with moderate (CK–MB: AUC = 0.788, p < 0.001) to high (CK: AUC = 0.811, p < 0.001) diagnostic accuracy. This reflected the excessive increase of the brain-type CK isoenzyme (CK–BB) following a TBI. The results provide evidence that CK immunoassays can be used as an adjunct quantitative test aid in diagnosing acute TBI-related fatalities.
Assessing protein biomarkers to detect lethal acute traumatic brain injuries in cerebrospinal fluid
(2021)
Diagnosing traumatic brain injury (TBI) from body fluids in cases where there are no obvious external signs of impact would be useful for emergency physicians and forensic pathologists alike. None of the previous attempts has so far succeeded in establishing a single biomarker to reliably detect TBI with regards to the sensitivity: specificity ratio in a post mortem setting. This study investigated a combination of body fluid biomarkers (obtained post mortem), which may be a step towards increasing the accuracy of biochemical TBI detection. In this study, serum and cerebrospinal fluid (CSF) samples from 30 acute lethal TBI cases and 70 controls without a TBI-related cause of death were evaluated for the following eight TBI-related biomarkers: brain-derived neurotrophic factor (BDNF), ferritin, glial fibrillary acidic protein (GFAP), interleukin 6 (IL-6), lactate dehydrogenase, neutrophil gelatinase-associated lipocalin (NGAL), neuron-specific enolase and S100 calcium-binding protein B. Correlations among the individual TBI biomarkers were assessed, and a specificity-accentuated threshold value analysis was conducted for all biomarkers. Based on these values, a decision tree modelling approach was performed to assess the most accurate biomarker combination to detect acute lethal TBIs. The results showed that 92.45% of acute lethal TBIs were able to be diagnosed using a combination of IL-6 and GFAP in CSF. The probability of detecting an acute lethal TBI was moderately increased by GFAP alone and considerably increased by the remaining biomarkers. BDNF and NGAL were almost perfectly correlated (p = 0.002; R\(^2\) = 0.944). This study provides evidence that acute lethal TBIs can be detected to a high degree of statistical accuracy using forensic biochemistry. The high inter-individual correlations of biomarkers may help to estimate the CSF concentration of an unknown biomarker, using extrapolation techniques.
Since the early days of Dirac flux quantization, magnetic monopoles have been sought after as a potential corollary of quantized electric charge. As opposed to magnetic monopoles embedded into the theory of electromagnetism, Weyl semimetals (WSM) exhibit Berry flux monopoles in reciprocal parameter space. As a function of crystal momentum, such monopoles locate at the crossing point of spin-polarized bands forming the Weyl cone. Here, we report momentum-resolved spectroscopic signatures of Berry flux monopoles in TaAs as a paradigmatic WSM. We carried out angle-resolved photoelectron spectroscopy at bulk-sensitive soft X-ray energies (SX-ARPES) combined with photoelectron spin detection and circular dichroism. The experiments reveal large spin- and orbital-angular-momentum (SAM and OAM) polarizations of the Weyl-fermion states, resulting from the broken crystalline inversion symmetry in TaAs. Supported by first-principles calculations, our measurements image signatures of a topologically non-trivial winding of the OAM at the Weyl nodes and unveil a chirality-dependent SAM of the Weyl bands. Our results provide directly bulk-sensitive spectroscopic support for the non-trivial band topology in the WSM TaAs, promising to have profound implications for the study of quantum-geometric effects in solids. Weyl semimetals exhibit Berry flux monopoles in momentum-space, but direct experimental evidence has remained elusive. Here, the authors reveal topologically non-trivial winding of the orbital-angular-momentum at the Weyl nodes and a chirality-dependent spin-angular-momentum of the Weyl bands, as a direct signature of the Berry flux monopoles in TaAs.
As part of the Clash of Realities International Conference on the Technology and Theory of Digital Games, the Game Technology Summit is a premium venue to bring together experts from academia and industry to disseminate state-of-the-art research on trending technology topics in digital games. In this first iteration of the Game Technology Summit, we specifically paid attention on how the successes in AI in Natural User Interfaces have been impacting the games industry (industry track) and which scientific, state-of-the-art ideas and approaches are currently pursued (scientific track).