Refine
Is part of the Bibliography
- yes (244)
Year of publication
Document Type
- Journal article (129)
- Doctoral Thesis (113)
- Other (1)
- Preprint (1)
Keywords
- MRI (22)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Kernspintomografie (8)
- Herzinfarkt (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (244) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
Background: Computed tomography (CT) pulmonary angiography is the diagnostic reference standard in suspected pulmonary embolism (PE). Favorable results for dual-energy CT (DECT) images have been reported for this condition. Nowadays, dual-energy data acquisition is feasible with different technical options, including a single-source split-filter approach. Therefore, the aim of this retrospective study was to investigate image quality and radiation dose of thoracic split-filter DECT in comparison to conventional single-energy CT in patients with suspected PE.
Methods: A total of 110 CT pulmonary angiographies were accomplished either as standard single-energy CT with automatic tube voltage selection (ATVS) (n=58), or as split-filter DECT (n=52). Objective [pulmonary artery CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] and subjective image quality [four-point Likert scale; three readers (R)] were compared among the two study groups. Size-specific dose estimates (SSDE), dose-length-product (DLP) and volume CT dose index (CTDIvol) were assessed for radiation dose analysis.
Results: Split-filter DECT images yielded 67.7% higher SNR (27.0 vs. 16.1; P<0.001) and 61.9% higher CNR (22.5 vs. 13.9; P<0.001) over conventional single-energy images, whereas CT attenuation was significantly lower (344.5 vs. 428.2 HU; P=0.013). Subjective image quality was rated good or excellent in 93.0%/98.3%/77.6% (R1/R2/R3) of the single-energy CT scans, and 84.6%/82.7%/80.8% (R1/R2/R3) of the split-filter DECT scans. SSDE, DLP and CTDIvol were significantly lower for conventional single-energy CT compared to split-filter DECT (all P<0.05), which was associated with 26.7% higher SSDE.
Conclusions: In the diagnostic workup of acute PE, the split-filter allows for dual-energy data acquisition from single-source single-layer CT scanners. The existing opportunity to assess pulmonary “perfusion” based on analysis of iodine distribution maps is associated with higher radiation dose in terms of increased SSDE than conventional single-energy CT with ATVS. Moreover, a proportion of up to 3.8% non-diagnostic examinations in the current reference standard test for PE is not negligible.
Objective:
Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals.
Methods:
Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses.
Results:
In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28% (interquartile range [IQR] 0.17–0.42%) in male and 0.24% (IQR 0.14–0.45%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g).
Conclusions:
The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers.
Objectives
To investigate the feasibility, diagnostic image quality and radiation dose of 3\(^{rd}\) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease.
Methods
We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scanprotocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP).
Results
All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv.
Conclusions
Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases.
Purpose
To evaluate whether a deep learning model (DLM) could increase the detection sensitivity of radiologists for intracranial aneurysms on CT angiography (CTA) in aneurysmal subarachnoid hemorrhage (aSAH).
Methods
Three different DLMs were trained on CTA datasets of 68 aSAH patients with 79 aneurysms with their outputs being combined applying ensemble learning (DLM-Ens). The DLM-Ens was evaluated on an independent test set of 104 aSAH patients with 126 aneuryms (mean volume 129.2 ± 185.4 mm3, 13.0% at the posterior circulation), which were determined by two radiologists and one neurosurgeon in consensus using CTA and digital subtraction angiography scans. CTA scans of the test set were then presented to three blinded radiologists (reader 1: 13, reader 2: 4, and reader 3: 3 years of experience in diagnostic neuroradiology), who assessed them individually for aneurysms. Detection sensitivities for aneurysms of the readers with and without the assistance of the DLM were compared.
Results
In the test set, the detection sensitivity of the DLM-Ens (85.7%) was comparable to the radiologists (reader 1: 91.2%, reader 2: 86.5%, and reader 3: 86.5%; Fleiss κ of 0.502). DLM-assistance significantly increased the detection sensitivity (reader 1: 97.6%, reader 2: 97.6%,and reader 3: 96.0%; overall P=.024; Fleiss κ of 0.878), especially for secondary aneurysms (88.2% of the additional aneurysms provided by the DLM).
Conclusion
Deep learning significantly improved the detection sensitivity of radiologists for aneurysms in aSAH, especially for secondary aneurysms. It therefore represents a valuable adjunct for physicians to establish an accurate diagnosis in order to optimize patient treatment.
Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDI\(_{vol}\) = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as “non-UHR”. Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ\(_{50}\) = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2–9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58–0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.
In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDI\(_{vol}\) 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1–3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732–0.848; p < 0.001) and fracture assessability (0.880; 0.842–0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0–3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise.
Hintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) können mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik ermöglicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualität sowie der Strahlendosis mit einem etabliertem DS-DECT-Gerät verglichen werden.
Material und Methoden: Insgesamt wurden 135 Patienten eingeschlossen, die eine CTPA erhielten: 68 erhielten einen DS-DECT-Scan mit 90/Sn150 kV und 67 einen SF-DECT-Scan mit Au/Sn120 kV. Für beide Protokolle wurden farbkodierte Joddistributionskarten erstellt. Die objektive (CT-Abschwächung in relevanten Gefäßen in HU, Signal-Rausch-Verhältnis (SNR), Kontrast-Rausch-Verhältnis (CNR), perfused blood volume (PBV)) und subjektive Bildqualität (2 Befunder (B), 5-Punkte-Likert-Skala) sowie Dosisparameter wurden erhoben und verglichen.
Ergebnisse: Alle CTPAs waren von diagnostischer Qualität. Ihre subjektive Bildqualität wurde in 80,9/82,4% (B1/B2) der DS-DECT und in 77,6/76,1% der SF-DECT als exzellent oder gut bewertet. Die subjektive Bildqualität der Joddistributionskarten der SF-DECT wurde von beiden Befundern als schlechter beurteilt. Die HU-Werte der relevanten Gefäße unterschieden sich nicht signifikant (p>0.05), SNR und CNR der SF-Gruppe waren in zentralen Gefäßen jedoch höher (p<0.05); die PBV-Werte der SF-Gruppe waren teils höher (p<0.05). Alle erhobenen Dosisparameter waren in der SF-Gruppe höher (p<0,05).
Konklusion: In der diagnostischen Abklärung eines V.a. eine akute LAE ermöglicht der Einsatz eines Split-Filters an einem Single-Source-CT-Scanner eine Dual-Energy-Untersuchung. Dies geht im Vergleich zu etablierten DS-Scannern jedoch mit einer schlechteren Qualität der Joddistributionskarten und einer höheren Strahlendosis einher.
Das Ziel dieser Arbeit war es, Methoden und Techniken für die morphologische und funktionelle Bildgebung der menschlichen Lunge mittels Kernspintomographie bei Feldstärken von 0,2 Tesla und 1,5 Tesla zu entwickeln und zu optimieren. Bei 0,2 Tesla wurde mittels der gemessenen Relaxationszeiten T1 und T2* eine 2D und eine 3D FLASH Sequenz zur Untersuchung der Lungenmorphologie optimiert. Sauerstoffgestützte Messungen der Relaxationszeiten T1 und T2* sowie eine SpinLabeling Sequenz liefern funktionelle Informationen über den Sauerstofftransfer und die Perfusion der Lungen. Bei 1,5 Tesla wurde die Lungenperfusion mittels MR-Kontrastmittel mit einer 2D und einer 3D Sequenz unter Verwendung der Präbolus Technik quantifiziert. Zudem wurden zwei MR-Navigationstechniken entwickelt, die es ermöglichen Lungenuntersuchungen unter freier Atmung durchzuführen und aus den Daten artefaktfreie Bilder zu rekonstruieren. Diese Techniken können in verschiedenste Sequenzen für die Lungenbildgebung implementiert werden, ohne dass die Messzeit dadurch signifikant verlängert wird.
Organ manifestations and long-term outcome of Fabry disease in patients with the GLA haplotype D313Y
(2016)
Objectives: The severity of Fabry disease is dependent on the type of mutation in the α-galactosidase A (AgalA) encoding gene (GLA). This study focused on the impact of the GLA haplotype D313Y on long-term organ involvement and function.
Setting and participants: In this monocentric study, all participants presenting with the D313Y haplotype between 2001 and 2015 were comprehensively clinically investigated at baseline and during a 4-year follow-up if available. Five females and one male were included.
Primary and secondary outcome measures: Cardiac, nephrological, neurological, laboratory and quality of life data.
Results: AgalA enzyme activity in leucocytes (0.3±0.9 nmol/min/mg protein (mean±SD)) and serum lyso-Gb3 (0.6±0.3 ng/mL at baseline) were in normal range in all patients. Cardiac morphology and function were normal (left-ventricular (LV) ejection fraction 66±8%; interventricular septum 7.7±1.4 mm; LV posterior wall 7.5±1.4 mm; normalised LV mass in MRI 52±9 g/m2; LV global longitudinal strain −21.6±1.9%) and there were no signs of myocardial fibrosis in cardiac MRI. Cardiospecific biomarkers were also in normal range. Renal function was not impaired (estimated glomerular filtration rate MDRD 103±15 mL/min; serum-creatinine 0.75±0.07 mg/dL; cystatin-c 0.71±0.12 mg/L). One female patient (also carrying a Factor V Leiden mutation) had a transitory ischaemic attack. One patient showed white matter lesions in brain MRI, but none had Fabry-associated pain attacks, pain crises, evoked pain or permanent pain. Health-related quality of life analysis revealed a reduction in individual well-being. At long-term follow-up after 4 years, no significant change was seen in any parameter.
Conclusions: The results of the current study suggest that the D313Y genotype does not lead to severe organ manifestations as seen in genotypes known to be causal for classical FD."
One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical …
Serotonergic modulation of 'waiting impulsivity' is mediated by the impulsivity phenotype in humans
(2016)
In rodents, the five-choice serial reaction time task (5-CSRTT) has been established as a reliable measure of waiting impulsivity being defined as the ability to regulate a response in anticipation of reinforcement. Key brain structures are the nucleus accumbens (NAcc) and prefrontal regions (for example, pre- and infralimbic cortex), which are, together with other transmitters, modulated by serotonin. In this functional magnetic resonance imaging study, we examined 103 healthy males while performing the 5-CSRTT measuring brain activation in humans by means of a paradigm that has been widely applied in rodents. Subjects were genotyped for the tryptophan hydroxylase-2 (TPH2; G-703T; rs4570625) variant, an enzyme specific for brain serotonin synthesis. We addressed neural activation patterns of waiting impulsivity and the interaction between the NAcc and the ventromedial prefrontal cortex (vmPFC) using dynamic causal modeling. Genetic influence was examined via interaction analyses between the TPH2 genotype (GG homozygotes vs T allele carriers) and the degree of impulsivity as measured by the 5-CSRTT. We found that the driving input of the vmPFC was reduced in highly impulsive T allele carriers (reflecting a reduced top-down control) in combination with an enhanced response in the NAcc after correct target processing (reflecting an augmented response to monetary reward). Taken together, we found a high overlap of our findings with reports from animal studies in regard to the underlying cognitive processes, the brain regions associated with waiting impulsivity and the neural interplay between the NAcc and vmPFC. Therefore, we conclude that the 5-CSRTT is a promising tool for translational studies.
Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury.
Popliteal cysts, or Baker cysts, are considered rare in children and may exhibit particular features, as compared with adults. We studied data from80 paediatric patients with 55 Baker cysts, examined over a period of 7 years, and correlated clinical presentation with findings on ultrasonography and MRI. Prevalence of popliteal cysts was 57% in arthritic knees, 58% with hypermobility syndrome, and 28% without risk factors. Only one patient had a trauma history and showed an ipsilateral cyst. Mean cyst volume was 3.4 mL; cysts were larger in boys. Patients with arthritis had echogenic cysts in 53%. Cyst communication with the joint space was seen in 64% on ultrasonography and 86% on MRI. In conclusion, Baker cysts are a common finding in a clinically preselected paediatric population. Children with Baker cysts should be assessed for underlying arthritis and inherited joint hypermobility, while sporadic Baker cysts appear to be common, as well.
Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies.
Background: Giant cell arteritis (GCA) is the most common systemic vasculitis in persons aged 50 and above (incidence, 3.5 per 100 000 per year). It affects cranial arteries, the aorta, and arteries elsewhere in the body, e.g., in the limbs.
Methods: We selectively review the pertinent literature, including guidelines and recommendations from Germany and abroad.
Results: The typical symptoms of new-onset GCA are bi-temporal headaches, jaw claudiacation, scalp tenderness, visual disturbances, systemic symptoms such as fever and weight loss, and polymyalgia. The diagnostic assessment comprises laboratory testing (erythrocyte sedimentation rate, C-reactive protein), imaging studies (duplex sonography, high-resolution magnetic resonance imaging, positron-emission tomography), and temporal artery biopsy. The standard treatment is with corticosteroids (adverse effects: diabetes mellitus, osteoporosis, cataract, arterial hypertension). A meta-analysis of three randomized controlled trials led to a recommendation for treatment with methotrexate to lower the recurrence rate and spare steroids. Patients for whom methotrexate is contraindicated or who cannot tolerate the drug can be treated with azathioprine instead.
Conclusion: Giant cell arteritis, if untreated, progresses to involve the aorta and its collateral branches, leading to various complications. Late diagnosis and treatment can have serious consequences, including irreversible loss of visual function.
Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words “brain”, “metastas*”, “tumor”, “colorectal”, “cancer”, and “malignancy”. In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1% and 11.5%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment.
Diese Arbeit untersucht die Fragestellung ob bei der Untersuchung von gesundem Hirngewebe und pathologischen,intrakraniellen Läsionen mittels Singelvoxel- versus Multivoxel-MR-Protonen-Spektroskopie signifikant unterschiedliche Ergebnisse bestehen. Untersucht wurden Hirntumoren der WHO-Grade 2 bis 4, Metastasen und fokal-entzündliche Läsionen. Zusammenfassend ist die Unterscheidung zwischen normalem und pathologisch verändertem Hirngewebe am besten mit der Singelvoxel-Methode und Bildung der CHO/CRE-Ratio möglich. Zur Differentialdiagnose und weiteren Malignitätseinschätzung eignet sich die Bildung der CHO/NAA-Ratio mit Singelvoxel-Spektroskopie. Weiterhin ist die parallele Anwendung von Singel- und Multivoxel-Spektroskopie empfehlenswert.
Background
Animal models are frequently used to assess new treatment methods in cancer research. MRI offers a non-invasive in vivo monitoring of tumour tissue and thus allows longitudinal measurements of treatment effects, without the need for large cohorts of animals. Tumour size is an important biomarker of the disease development, but to our knowledge, MRI based size measurements have not yet been verified for small tumours (10−2–10−1 g). The aim of this study was to assess the accuracy of MRI based tumour size measurements of small tumours on mice.
Methods
2D and 3D T2-weighted RARE images of tumour bearing mice were acquired in vivo using a 7 T dedicated animal MR system. For the 3D images the acquired image resolution was varied. The images were exported to a PC workstation where the tumour mass was determined assuming a density of 1 g/cm3, using an in-house developed tool for segmentation and delineation. The resulting data were compared to the weight of the resected tumours after sacrifice of the animal using regression analysis.
Results
Strong correlations were demonstrated between MRI- and necropsy determined masses. In general, 3D acquisition was not a prerequisite for high accuracy. However, it was slightly more accurate than 2D when small (<0.2 g) tumours were assessed for inter- and intraobserver variation. In 3D images, the voxel sizes could be increased from 1603 μm3 to 2403 μm3 without affecting the results significantly, thus reducing acquisition time substantially.
Conclusions
2D MRI was sufficient for accurate tumour size measurement, except for small tumours (<0.2 g) where 3D acquisition was necessary to reduce interobserver variation. Acquisition times between 15 and 50 minutes, depending on tumour size, were sufficient for accurate tumour volume measurement. Hence, it is possible to include further MR investigations of the tumour, such as tissue perfusion, diffusion or metabolic composition in the same MR session.
Zielsetzung: Harmonic Imaging produziert Bilder mit hoher Orts- und Kontrastauflösung. Die Mikrobläschen im verwendeten Kontrastmittel werden deutlich sichtbarer. Ziel dieser Studie war es, das diagnostische Potential der kontrastverstärkten Miktionsurosonographie (MUS) mittels Harmonic Imaging bei reduzierter Kontrastmitteldosis mit der Miktionszystourethrographie (MCU) zu vergleichen. Material und Methodik: 55 Patienten (17 Jungen, 38 Mädchen; Durchschnittsalter 4 Jahre), die zur Refuxuntersuchung kamen, wurden für die Vergleichsstudie rekrutiert. Im Anschluß an einen Standard-Ultraschall des Harntraktes mit Harmonic Imaging (Sonoline Elegra, Siemens) folgte die Blasenkatheterisierung und die intravesikale Gabe des Ultraschallkontrastmittels Levovist® (300 mg/ml). Anstatt der bei MUS mit konventioneller Ultraschallmodalität verwendeten Menge – 10% des Blasenvolumens – wurde jetzt nur 5% Volumen des Kontrastmittels benutzt. Die Sonographie des Harntraktes wurde wiederholt und auch unter Miktion fortgeführt. Es schloss sich ein MCU an. Ergebnisse: Zur Evaluation standen insgesamt 114 Nieren-Ureter-Einheiten (NUE) zur Verfügung. In 29 NUE wurde mit einer oder beiden Methoden ein vesikoureteraler Reflux (VUR) diagnostiziert. In 7 NUE wurde der Reflux nur mit Hilfe der MUS, in 3 NUE nur mittels MCU diagnostiziert. Beim Vergleich der MUS mit der Referenzmethode MCU waren die diagnostischen Ergebnisse folgendermaßen: 86,4% Sensitivität, 92,4% Spezifität, 73,1% positiver Vorhersagewert und 96,6% negativer Vorhersagewert. Der Korrelationskoeffizient zwischen den beiden Methoden betrug 0,741 (p<0,001). Schlußfolgerungen: MUS mit Harmonic Imaging und halbierter Kontrastmitteldosis ist in Bezug auf Ausschluß und Diagnose eines VUR mit der MCU vergleichbar. Die Reduktion der Kontrastmittelmenge schränkt die Aussagefähigkeit der MUS nicht ein, sondern ermöglicht bei gleichen Ergebnissen eine kostengünstigere Untersuchung.