Refine
Has Fulltext
- yes (76)
Is part of the Bibliography
- yes (76)
Year of publication
Document Type
- Doctoral Thesis (51)
- Journal article (25)
Keywords
- MRI (76) (remove)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (21)
- Physikalisches Institut (20)
- Medizinische Klinik und Poliklinik I (9)
- Graduate School of Life Sciences (6)
- Neurologische Klinik und Poliklinik (5)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (3)
- Klinik und Poliklinik für Nuklearmedizin (3)
- Klinik und Poliklinik für Psychiatrie, Psychosomatik und Psychotherapie (3)
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (3)
- Medizinische Klinik (bis 2004) (3)
Sonstige beteiligte Institutionen
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Experimental Physics V, University of Wuerzburg (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Johns Hopkins School of Medicine (1)
- MRB Research Center for Magnetic-Resonance-Bavaria (1)
- Zentrum für Luft- und Raumfahrtmedizin der Luftwaffe (1)
In der Diagnostik der KHK und für die richtige Therapieentscheidung ist die myokardiale Perfusion von besonderem Interesse. Die verminderte Mikrozirkulation als funktionelle Folge einer Stenose korreliert mit den Beschwerden und der Prognose für einen Patienten mit KHK besser als die Morphologie der Stenose selbst. In der koronaren Angiographie wird die vaskuläre Situation der Herzkranzgefäße beurteilt und in Stenosegrade eingeteilt. Die Stenosen bedingen aber häufig nicht die entsprechende myokardiale Minderdurchblutung, so dass oft zusätzliche Untersuchungen der Ischämiediagnostik wie beispielsweise die Myokardszintigraphie oder die Stressechokardiographie erforderlich sind. Die MR-Perfusionsmessung kann bereits zur KHK-Primärdiagnostik eingesetzt werden. Die Bestimmung der hämodynamischen Relevanz einer Stenose und der Nachweis einer mikrovaskulärern Obstruktion nach Infarkt und die Therapiekontrolle nach Revaskularisierung ist möglich. Hier könnte in Zukunft die quantitative MR Perfusionsmessung den Vergleich von MR Perfusionsmessungen mit anderen Modalitäten erleichtern. Die Magnetresonanztomographie für die Bestimmung der Herzperfusion wird zunehmend in der Klinik angewendet. Die Auswertung erfolgt in der Regel nicht quantitativ, sondern rein visuell. Die quantitative Bestimmung der myokardialen Perfusion mittels MRT ist Gegenstand der aktuellen Forschung. In der vorliegenden Arbeit wurde die von Köstler beschriebene Präbolus Technik eingesetzt, die quantitative Aussagen über die myokardiale Perfusion mit einer geringen Variabilität ermöglicht. Diese Untersuchungstechnik wurde bei herzgesunden Probanden getestet. Für die quantitativen Perfusionsuntersuchungen wurde das Myokard in allen Bildern manuell segmentiert (d.h. markiert). Anschließend wurden aus den segmentierten Bildern Konzentrations-Zeit-Kurven im Myokard und im linken Ventrikel bestimmt. Aus diesen Kurven wurden durch Entfaltung mit der arteriellen Inputfunktion zu einer Modellfunktion quantitative Werte für die Perfusion gemessen. Das Ziel dieser Studie war die Untersuchung verschiedener Aspekte der Auswerteverfahren in der Herzperfusionsdiagnostik, um die Auswertung optimieren zu können. Die Untersuchungen für die quantitative Bestimmung der Myokardperfusion erfolgten mittels Präbolus-Technik und einer Multislice SSFP-Sequenz. Zur Bestimmung einer optimierten Segmentation des Myokards bei der quantitativen Bestimmung der Herzperfusion in der MRT ist es möglich, die tatsächlichen Myokardgrenzen zu verwenden, wenn eine Kontaminationskorrektur eingesetzt wird. Dabei wird das Signal-zu-Rausch-Verhältnis verbessert und die Variabilität der Perfusionswerte vermindert. Die subendokardiale und subepikardiale Perfusion können bestimmt werden. Die Untersuchung der Perfusion der subendo- und subepikardialen Schicht des menschlichen Herzens zeigte bei den untersuchten gesunden Probanden eine höhere Perfusion der subendokardialen Anteile. Künftig könnten auch in der klinischen Routine subendo- und subepikardiale Schichten getrennt ausgewertet werden, um somit eine Differenzierung eines Perfusionsdefizites zu ermöglichen. Ziel ist es, auch kleine Durchblutungsstörungen oder eine Minderdurchblutung nur der inneren Schichten des Herzmuskels quantitativ nachzuweisen. Hierzu müssen die Ergebnisse dieser Studie mit Ergebnissen von Patienten verglichen werden. Werden die Werte von quantitativen Perfusionsauswertungen mit einer Fermi- oder Exponentialfunktion ausgewertet, zeigt sich ein linearer Zusammenhang der Ergebnisse, die ineinander umgerechnet werden können. Beide Modellfunktionen sind somit für die Auswertung der Herzperfusionsuntersuchung einsetzbar. Des Weiteren wurde gezeigt, dass es durch die Entfaltung der Konzentrations-Zeit-Kurven möglich ist, die myokardiale Perfusion bei gesunden Probanden korrekt zu messen, auch wenn nur die Bilder jedes n-ten Herzschlages berücksichtigt werden. Patientenstudien müssen zeigen, ob dies auch für minderperfundierte Areale zutrifft und ob diese eindeutig determiniert werden können. Die Interobservervariabilität liegt in der Größenordung der Streuung der Flusswerte bei gesunden Probanden. Die Beurteilbarkeit unterschiedlicher Regionen des Herzens hinsichtlich der Mikrozirkulation und der daraus abzuleitenden therapeutischen Konsequenzen sind das primäre Ziel. Mit der quantitativen MR-Herz-Perfusionsmessung soll ein validiertes diagnostisches Instrumentarium für die Bestimmung der Herzdurchblutung zur Verfügung gestellt werden. Diese Arbeit liefert einen Beitrag zur Optimierung der Auswertung der Herzperfusion und hilft damit den Stellenwert der MR-Herzperfusionsmessung zu verbessern. Die MRT könnte auf Grund der hohen räumlichen Auflösung und der Möglichkeit der Quantifizierung in Zukunft zum Goldstandard bei Herzperfusionsuntersuchungen werden
Vaccinia virus plays an important role in human medicine and molecular biology ever since the 18th century after E. Jenner discovered its value as a vaccination virus against smallpox. After the successful eradication of smallpox, vaccinia virus, apart from its use as a vaccine carrier, is today mainly used as a viral vector in molecular biology and increasingly in cancer therapy. The capability to specifically target and destroy cancer cells makes it a perfect agent for oncolytic virotherapy. Furthermore, the virus can easily be modified by inserting genes encoding therapeutic or diagnostic proteins to be expressed within the tumor. The emphasis in this study was the diagnosis of tumors using different vaccinia virus strains. Viruses with metal-accumulating capabilities for tumor detection via MRI technology were generated and tested for their usefulness in cell culture and in vivo. The virus strains GLV-1h131, GLV-1h132, and GLV-1h133 carry the gene encoding the two subunits of the iron storage protein ferritin under the control of three different promoters. GLV-1h110, GLV-1h111, and GLV-1h112 encode the bacterial iron storage protein bacterioferritin, whereas GLV-1h113 encodes the codon-optimized version of bacterioferritin for more efficient expression in human cells. GLV-1h22 contains the transferrin receptor gene, which plays an important role in iron uptake, and GLV-1h114 and GLV-1h115 contain the murine transferrin receptor gene. For possibly better iron uptake the virus strains GLV-1h154, GLV-1h155, GLV-1h156, and GLV-1h157 were generated, each with a version of a ferritin gene and a transferrin receptor gene. GLV-1h154 carries the genes that encode bacterioferritin and human transferrin receptor, GLV-1h155 the human ferritin H-chain gene and the human transferrin receptor gene. GLV-1h156 and GLV-1h157 infected cells both express the mouse transferrin receptor and bacterioferritin or human ferritin H-chain, respectively. The virus strains GLV-1h186 and GLV-1h187 were generated to contain a mutated form of the ferritin light chain, which was shown to result in iron overload and the wildtype light chain gene, respectively. The gene encoding the Divalent Metal Transporter 1, which is a major protein in the uptake of iron, was inserted in the virus strain GLV-1h102. The virus strain GLV-1h184 contains the magA gene of the magnetotactic bacterium Magnetospirillum magnetotacticum, which produces magnetic nanoparticles for orientation in the earth’s magnetic field. Initially the infection and replication capability of all the virus strains were analyzed and compared to that of the parental virus strain GLV-1h68, revealing that all the viruses were able to infect cells of the human cancer cell lines A549 and GI-101A. All constructs exhibited a course of infection comparable to that of GLV-1h68. Next, to investigate the expression of the foreign proteins in GI-101A and A549 cells with protein analytical methods, SDS-gelelectrophoresis, Western blots and ELISAs were performed. The proteins, which were expressed under the control of the strong promoters, could be detected using these methods. To be able to successfully detect the protein expression of MagA and DMT1, which were expressed under the control of the weak promoter, the more sensitive method RT-PCR was used to at least confirm the transcription of the inserted genes. The determination of the iron content in infected GI-101A and A549 cells showed that infection with all used virus strains led to iron accumulation in comparison to uninfected cells, even infection with the parental virus strain GLV-1h68. The synthetic phytochelatin EC20 was also shown to enhance the accumulation of different heavy metals in bacterial cultures. In vivo experiments with A549 tumor-bearing athymic nude mice revealed that 24 days post infection virus particles were found mainly in the tumor. The virus-mediated expression of recombinant proteins in the tumors was detected successfully by Western blot. Iron accumulation in tumor lysates was investigated by using the ferrozine assay and led to the result that GLV-1h68-infected tumors had the highest iron content. Histological stainings confirmed the finding that iron accumulation was not a direct result of the insertion of genes encoding iron-accumulating proteins in the virus genome. Furthermore virus-injected tumorous mice were analyzed using MRI technology. Two different measurements were performed, the first scan being done with a seven Tesla small animal scanner seven days post infection whereas the second scan was performed using a three Tesla human scanner 21 days after virus injection. Tumors of mice injected with the virus strains GLV-1h113 and GLV-1h184 were shown to exhibit shortened T2 and T2* relaxation times, which indicates enhanced iron accumulation. In conclusion, the experiments in this study suggest that the bacterioferritin-encoding virus strain GLV-1h113 and the magA-encoding virus strain GLV-1h184 are promising candidates to be used for cancer imaging after further analyzation and optimization.
Background
A new thromboembolic animal model showed beneficial effects of t-PA with an infarct volume reduction of 36.8% in swiss mice. Because knock-out animal experiments for stroke frequently used C57BL76 mice we evaluated t-PA effects in this mouse strain and measured infarct volume and vascular recanalisation in-vivo by using high-field 9.4 T MRI and a 1H surface cryo coil.
Methods
Clot formation was triggered by microinjection of murine thrombin into the right middle cerebral artery (MCA). Animals (n = 28) were treated with 10 mg/kg, 5 mg/kg or no tissue plasminogen activator (t-PA) 40 min after MCA occlusion. For MR-imaging a Bruker 9.4 T animal system with a 1H surface cryo probe was used and a T2-weighted RARE sequence, a diffusion weighted multishot EPI sequence and a 3D flow-compensated gradient echo TOF angiography were performed.
Results
The infarct volume in animals treated with t-PA was significantly reduced (0.67 ± 1.38 mm3 for 10 mg/kg and 10.9 ± 8.79 mm3 for 5 mg/kg vs. 19.76 ± 2.72 mm3 ; p < 0.001) compared to untreated mice. An additional group was reperfused with t-PA inside the MRI. Already ten minutes after beginning of t-PA treatment, reperfusion flow was re-established in the right MCA. However, signal intensity was lower than in the contralateral MCA. This reduction in cerebral blood flow was attenuated during the first 60 minutes after reperfusion. 24 h after MCA occlusion and reperfusion, no difference in signal intensity of the contralateral and ipsilateral MCAs was observed.
Conclusions
We confirm a t-Pa effect using this stroke model in the C57BL76 mouse strain and demonstrate a chronological sequence MRI imaging after t-PA using a 1H surface cryo coil in a 9.4 T MRI. This setting will allow testing of new thrombolytic strategies for stroke treatment in-vivo in C57BL76 knock-out mice.
Nuclear Magnetic Resonance (NMR) provides a highly flexible platform for non invasive analysis and imaging biological samples, since the manipulation of nuclear spin allows the tailoring of experiments to maximize the informativeness of the data. MRI is capable of visualizing a holistic picture of the lipid storage in living plant/seed. This review has sought to explain how the technology can be used to acquire functional and physiological data from plant samples, and how to exploit it to characterize lipid deposition in vivo. At the same time, we have referred to the current limitations of NMR technology as applied to plants, and in particular of the difficulty of transferring methodologies optimized for animal/medical subjects to plant ones. A forward look into likely developments in the field is included, anticipating its key future role in the study of living plant.
Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. \(^{18}\)F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 & PLUSMN; 57.7 mu l*, 380.8 & PLUSMN; 57.2 mu l*, 398.0 & PLUSMN; 63.1 mu l*, and 444.8 & PLUSMN; 75.3 mu l at 4, 8, 12, and 16 frames, respectively; *P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed (P < 0.005), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used.
Obsessive compulsive disorder (OCD) and attention deficit hyperactivity disorder (ADHD) are two of the most common neuropsychiatric diseases in paediatric populations. The high comorbidity of ADHD and OCD with each other, especially of ADHD in paediatric OCD, is well described. OCD and ADHD often follow a chronic course with persistent rates of at least 40–50 %. Family studies showed high heritability in ADHD and OCD, and some genetic findings showed similar variants for both disorders of the same pathogenetic mechanisms, whereas other genetic findings may differentiate between ADHD and OCD. Neuropsychological and neuroimaging studies suggest that partly similar executive functions are affected in both disorders. The deficits in the corresponding brain networks may be responsible for the perseverative, compulsive symptoms in OCD but also for the disinhibited and impulsive symptoms characterizing ADHD. This article reviews the current literature of neuroimaging, neurochemical circuitry, neuropsychological and genetic findings considering similarities as well as differences between OCD and ADHD.
In der vorliegenden Arbeit wurden magnetische Kolloide auf der Basis von Eisenoxid-Nanopartikeln hergestellt, die eine erhöhte Verweildauer im Blutstrom aufweisen sollten. Die Hüllmoleküle bestehen aus zwei Teilen: Direkt an den Phosphor gebunden eine hydrophobe Alkylkette aus vier bis zehn CH2-Einheiten, und daran anschließend eine Methoxy-terminierte Polyethylenglykol (PEG)-Kette. Die PEG-Kette sollte sowohl die Hydrophilie der fertigen Partikel als auch den nötigen Schutz gegen Phagozytose gewährleisten. Diese speziellen Phosphonsäuren wurden dann dazu verwendet, Magnetit-Nanopartikel stabil einzuhüllen.
Die vorliegende Arbeit beschäftigt sich mit der Synthese neuer heptadentater Liganden und deren Gd(III)- und Y(III)-Komplexen. Diese auf dem AAZTA-Grundgerüst basierenden Liganden sollten in 6-Position des Perhydro-1,4-diazepinrings über eine zusätzliche funktionelle Gruppe verfügen, wodurch eine kovalente Anbindung der entsprechenden Gd(III)-Komplexe an Makromoleküle, Polymere oder Peptide möglich wäre. Abschließend wurden die Protonen-Relaxivitäten der darge¬stellten Gd(III)-Komplexe bestimmt, und die Komplexe bezüglich ihrer Eignung als Kontrastmittel bei der MRI untersucht.
Acute ischemic cardiac injury predisposes one to cognitive impairment, dementia, and depression. Pathophysiologically, recent positron emission tomography data suggest astroglial activation after experimental myocardial infarction (MI). We analyzed peripheral surrogate markers of glial (and neuronal) damage serially within 12 months after the first ST-elevation MI (STEMI). Serum levels of glial fibrillary acidic protein (GFAP) and neurofilament light chain (NfL) were quantified using ultra-sensitive molecular immunoassays. Sufficient biomaterial was available from 45 STEMI patients (aged 28 to 78 years, median 56 years, 11% female). The median (quartiles) of GFAP was 63.8 (47.0, 89.9) pg/mL and of NfL 10.6 (7.2, 14.8) pg/mL at study entry 0–4 days after STEMI. GFAP after STEMI increased in the first 3 months, with a median change of +7.8 (0.4, 19.4) pg/mL (p = 0.007). It remained elevated without further relevant increases after 6 months (+11.7 (0.6, 23.5) pg/mL; p = 0.015), and 12 months (+10.3 (1.5, 22.7) pg/mL; p = 0.010) compared to the baseline. Larger relative infarction size was associated with a higher increase in GFAP (ρ = 0.41; p = 0.009). In contrast, NfL remained unaltered in the course of one year. Our findings support the idea of central nervous system involvement after MI, with GFAP as a potential peripheral biomarker of chronic glial damage as one pathophysiologic pathway.
Background:
Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly.
Methods:
Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test.
Results:
Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle.
Conclusion:
These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.
Adipose tissue-derived stromal cells (ASCs) represent a capable source for cell-based therapeutic approaches. For monitoring a cell-based application in vivo, magnetic resonance imaging (MRI) of cells labeled with iron oxide particles is a common method. It is the aim of the present study to analyze potential DNA damage, cytotoxicity and impairment of functional properties of human (h)ASCs after labeling with citrate-coated very small superparamagnetic iron oxide particles (VSOPs). Cytotoxic as well as genotoxic effects of the labeling procedure were measured in labeled and unlabeled hASCs using the MTT assay, comet assay and chromosomal aberration test. Trilineage differentiation was performed to evaluate an impairment of the differentiation potential due to the particles. Proliferation as well as migration capability were analyzed after the labeling procedure. Furthermore, the labeling of the hASCs was confirmed by Prussian blue staining, transmission electron microscopy (TEM) and high-resolution MRI. Below the concentration of 0.6 mM, which was used for the procedure, no evidence of genotoxic effects was found. At 0.6 mM, 1 mM as well as 1.5 mM, an increase in the number of chromosomal aberrations was determined. Cytotoxic effects were not observed at any concentration. Proliferation, migration capability and differentiation potential were also not affected by the procedure. Labeling with VSOPs is a useful labeling method for hASCs that does not affect their proliferation, migration and differentiation potential. Despite the absence of cytotoxicity, however, indications of genotoxic effects have been demonstrated.
Einleitung: Zwischen 1994-2003 wurden in Zusammenarbeit von HNO- und Neurochirurgie 615 Vestibularschwannome (Grad T3a-T4b) über den subokzipitalen Zugang operiert. In 89 Fällen (14%) konnte aus unterschiedlichen Gründen der Tumor nur inkomplett entfernt werden. Mittels neurologischer Untersuchung und MRT wurde postoperativ das funktionelle Ergebnis bzw. das Wachstumsverhalten des Resttumors untersucht. Außerdem wurden die Art des Resttumors und die Gründe für eine inkomplette Resektion analysiert. Material und Methoden: Alle Tumore wurden unter stetigem Neuromonitoring (AEP, Fazialis-EMG) operiert. Reichte der Tumor bis an die kaudalen Hirnnerven (IX, X, XI, XII) heran, wurden diese ebenfalls überwacht. In der postoperativen Kontrolle erfolgten eine neurologische Untersuchung und eine MRT. Die Ergebnisse wurden mit vorausgegangenen Untersuchungen verglichen, um das Wachstumsverhalten des Resttumors und das funktionelle Ergebnis zu beurteilen. Die Operationsberichte wurden nach den Gründen der inkompletten Tumorentfernung gesichtet. Ergebnisse: Starke Adhärenz des Tumorgewebes zu den Hirnnerven (VII, VIII, kaudale Gruppe) oder zum Hirnstamm, interfaszikuläre Tumornester, eine Gefährdung der Blutversorgung, spontane Entladungen im EMG oder eine reduzierte Ableitbarkeit der AEPs zwangen den Operateur, die Präparation abzubrechen. Die durchschnittliche Tumorgröße in den Fällen der inkompletten Resektion betrug 26,8 mm vs. 19,4 mm bei kompletter Tumorentfernung. Der zurückgelassene Tumorrest bestand in 86% aus einem Kapselanteil, einem Tumorrasen oder interfaszikulären Tumornestern. Grobe Tumorreste waren die Ausnahme. 12 Monate postoperativ wurde bei den Patienten mit kompletter Resektion in 88% eine gute bis sehr gute Funktionalität (House/Brackmann Grad I-II) des Gesichtsnervs beobachtet, bei inkompletter Tumorentfernung in 75%. 66% (n=59) der Resttumore zeigten keine Progredienz, 13% (n=12) eine Wachstumstendenz ohne klinische Symptomatik, 6% (n=5) mussten erneut operiert werden (15%/n=13 keine Kontrolle). Der durchschnittliche Nachbeobachtungszeitraum betrug 48,1 Monate (1-134). Zusammenfassung: Trotz Zurücklassens eines Tumorrestes kommt es nur selten zu einem erneuten Tumorwachstum. In noch weniger Fällen muss eine Rezidivoperation durchgeführt werden. Dies rechtfertigt eine subtotale Tumorresektion in den Fällen einer Hirnnervengefährdung. Verzichtet man auf eine komplette Resektion, lässt sich auch bei sehr großen Tumoren ein gutes bis sehr gutes funktionelles Ergebnis erzielen.
Das Ziel dieser Promotion ist der Aufbau eines dreMR Setups für einen klinischen 1,5T Scanner, das die Relaxations-Dispersions-Bildgebung ermöglicht, und die anschließende Ergründung von möglichst vielen Anwendungsfeldern von dreMR. Zu der Aufgabe gehört die Bereitstellung der zugrunde liegenden Theorie, der Bau des experimentellen Setups (Offset-Spule und Stromversorgung) sowie die Programmierung der nötigen Software. Mit dem gebauten Setup konnten zwei große Anwendungsfelder — dreMR Messungen mit und ohne Kontrastmitteln — untersucht werden.
This work considered the frequency-modulated balanced steady-state free precession (fm-bSSFP) sequence as a tool to provide banding free bSSFP MR images. The sequence was implemented and successfully applied to suppress bandings in various in vitro and in vivo examples. In combination with a radial trajectory it is a promising alternative for standard bSSFP applications. First, two specialized applications were shown to establish the benefits of the acquisition strategy in itself. In real time cardiac imaging, it was shown that the continuous shift in frequency causes a movement of the bandings across the FOV. Thus, no anatomical region is constantly impaired, and a suitable timeframe can be found to examine all important structures. Furthermore, a combination of images with different artifact positions, similar to phase-cycled acquisitions is possible. In this way, fast, banding-free imaging of the moving heart was realized. Second, acquisitions with long TR were shown. While standard bSSFP suffers from increasing incidence of bandings with higher TR values, the frequency-modulated approach provided banding free images, regardless of the TR.
A huge disadvantage of fm-bSSFP, in combination with the radial trajectory, is the decrease in signal intensity. In this work a specialized reconstruction method, the multifrequency reconstruction for frequency-modulated bSSFP (Muffm), was established, which successfully compensated that phenomena. The application of Muffm to several anatomical sites, such as inner ear, legs and cardiac acquisitions, proofed the advantageous SNR of the reconstruction.
Furthermore, fm-bSSFP was applied to the clinically highly relevant task of water-fat separation. Former approaches of a phase-sensitive separation procedure in combination with standard bSSFP showed promising results but failed in cases of high inhomogeneity or high field strengths where banding artifacts become a major issue. The novel approach of using the fm-bSSFP acquisition strategy with the separation approach provided robust, reliable images of high quality. Again, losses in signal intensity could be regained by Muffm, as both approaches are completely compatible.
Opposed to conventional banding suppression techniques, like frequency-scouts or phase-cycling, all reconstruction methods established in this work rely on a single radial acquisition, with scan times similar to standard bSSFP scans. No prolonged measurement times occur and patient time in the scanner is kept as short as possible, improving patient comfort, susceptibility to motion or physiological noise and cost of one scan.
All in all, the frequency-modulated acquisition in combination with specializes reconstruction methods, leads to a completely new quality of images with short acquisition times.
Objective: To determine whether rats reaching the same body mass, having been fed either a low-fat (LFD) or a high-fat diet (HFD), differ in white adipose tissue (WAT) deposition. Methods: In experiment 1, 22 Sprague-Dawley rats of the same age were divided into 11 rats with body mass below the batch median and fed a HFD, and 11 above the median and fed a LFD. In experiment 2, 20 Sprague-Dawley rats of the same age and starting body mass were randomised to either a HFD or LFD. When all groups reached similar final body mass, WAT was quantified using magnetic resonance imaging (MRI), dissection, and plasma leptin. Results: In experiment 1, both groups reached similar final body mass at the same age; in experiment 2 the HFD group reached similar final body mass earlier than the LFD group. There were no significant differences in WAT as assessed by MRI or leptin between the HFD and LFD groups in both experiments. Dissection revealed a trend for higher retroperitoneal and epididymal adiposity in the HFD groups in both experiments. Conclusions: We conclude that at similar body mass, adiposity is independent of the macronutrient composition of the feeding regimen used to achieve it. (C) 2014 S Karger GmbH, Freiburg
The focus of the work concerned the development of a series of MRI techniques that were specifically designed and optimized to obtain quantitative and spatially resolved information about characteristic parameters of the lung. Three image acquisition techniques were developed. Each of them allows to quantify a different parameter of relevant diagnostic interest for the lung, as further described below:
1) The blood volume fraction, which represents the amount of lung water in the intravascular compartment expressed as a fraction of the total lung water. This parameter is related to lung perfusion.
2) The magnetization relaxation time T\(_2\) und T*\(_2\)
, which represents the component of T\(_2\) associated with the diffusion of water molecules through the internal magnetic field gradients of the lung. Because the amplitude of these internal gradients is related to the alveolar size, T\(_2\) und T*\(_2\) can be used to obtain information about the microstructure of the lung.
3) The broadening of the NMR spectral line of the lung. This parameter depends on lung inflation and on the concentration of oxygen in the alveoli. For this reason, the spectral line broadening can be regarded as a fingerprint for lung inflation; furthermore, in combination with oxygen enhancement, it provides a measure for lung ventilation.
Die 31P-MRS wird zur Diagnostik des Energiemetabolismus bei verschiedenen kardialen Erkrankungen eingesetzt. Die vorliegende Arbeit befasst sich mit einer Verbesserung und Vereinfachung der Quantifzierung kardialer Energiemetaboliten mittels der 31P-MRS. Durch Akquisitonsgewichtung kann eine genauere Beurteilung der Konzentrationen von PCr und ATP im gesunden Myokard durch Verbesserung der Effizienz und Sensitivität der 31P-MRS erreicht werden. Die Kontamination des MR-Signals durch die Brustwand wird mittels des CORRECT-SLIM-Algorithmus verringert. Eine Fallstudie am rechten Ventrikel zeigt die starke metabolische Aussagekraft der 31P-MRS vor, während und nach medikamentöser Therapie. Die 31P-MRS unter Verwendung räumlicher Sättigungspulse liefert einen unmittelbaren Einblick in den Energiemetabolismus des menschlichen Herzens mit einer deutlich kürzen Nachbearbeitungszeit. Durch diese Optimierungen ermöglicht die 31P-MRS des menschlichen Herzens eine exakte Beurteilung des Energiemetabolismus im gesunden wie erkrankten Myokard.
Background
Imaging results are frequently considered as hallmarks of disease by spine surgeons to plan their future treatment strategy. Numerous classification systems have been proposed to quantify or grade lumbar magnetic resonance imaging (MRI) scans and thus objectify imaging findings. The clinical impact of the measured parameters remains, however, unclear. To evaluate the pathological significance of imaging findings in patients with multisegmental degenerative findings, clinicians can perform image-guided local infiltrations to target defined areas such as the facet joints.
The aim of the present retrospective study was to evaluate the correlation of MRI facet joint degeneration and spinal stenosis measurements with improvement obtained by image-guided intraarticular facet joint infiltration.
Methods
Fifty MRI scans of patients with chronic lumbar back pain were graded radiologically using a wide range of classification and measurement systems. The reported effect of facet joint injections at the site was recorded, and a comparative analysis performed.
Results
When we allocated patients according to their reported pain relief, 27 showed no improvement (0–30%), 16 reported good improvement (31–75%) and 7 reported excellent improvement (> 75%). MRI features assessed in this study did, however, not show any relevant correlation with reported pain after facet joint infiltration: Values for Kendall’s tau ranged from \(\tau\) = − 0.190 for neuroforaminal stenosis grading as suggested by Lee, to \(\tau\) = 0.133 for posterior disc height as proposed by Hasegawa.
Conclusion
Despite the trend in evidence-based medicine to provide medical algorithms, our findings underline the continuing need for individualised spine care that, along with imaging techniques or targeted infiltrations, includes diagnostic dimensions such as good patient history and clinical examination to formulate a diagnosis.
Trial registration
ClinicalTrials.gov, NCT03308149, retrospectively registered October 2017
Das Hauptziel der vorliegenden Arbeit war es, eine genauere Erkenntnis über die derzeitigen Möglichkeiten der quantitativen Messung der myokardiale Perfusion im Hinblick auf die Beschreibung verschiedener myokardialer Infarkte mittels kardialer MRT zu gewinnen. Die Untersuchungen zur Perfusion im Infarktgebiet ergaben, dass ein visuell festgestellter subendokardialer Infarkt an Hand der Bestimmung der absoluten Perfusion nicht immer nachvollzogen werden konnte. Ein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Höhe der absoluten Perfusion im Infarktgebiet konnte nicht gezeigt werden. Die Untersuchungen zur Perfusion im Remote Myokard ergaben keinen Zusammenhang zwischen der Perfusion im Remote Myokard und dem transmuralen Ausmaß des no-reflow-Phänomens in der First Pass Perfusion. Auch korrelierte die Perfusion im Remote Myokard nicht mit dem Auftreten eines no-reflow Phänomens im Late Enhancement. Die Perfusion im Remote Myokard unterschied sich zwischen transmuralen und nicht-transmuralen Infarkten. Eine Hyperperfusion im Remote Myokard konnte erst ab einer Infarktausdehnung von 75% im Late Enhancement beobachtet werden, während eine Hypoperfusion im Remote Myokard bei allen Infarktausdehnungen zwischen 0% und 100% auftrat. Die Untersuchungen zur Perfusion bei Vorliegen eines transmuralen Infarktes“ ergaben eine signifikante Korrelation der Perfusionen in Infarktgebiet und Remote Myokard bei transmuralem Infarkten. Die Ergebnisse zur Messung der Perfusion in Abhängigkeit von der relativen Infarktgröße wiesen keinen Zusammenhang zwischen der Perfusion im Infarktgebiet und der relativen Infarktgröße auf. Ebenso konnte keine Beziehung zwischen der Perfusion im Remote Myokard und der relativen Infarktgröße dargelegt werden. Letztendlich wurde das Verhalten der quantitativen Perfusion im Infarktgebiet und im Remote Myokard in Abhängigkeit von der Zeit nach Infarktereignis untersucht. Dabei zeigte sich kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Infarktgebiet zwischen der Erst- und der Spätuntersuchung. Ebenso war kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Remote Myokard zwischen der Erst- und der Spätuntersuchung erkennbar. Die kardiale MRT ist aufgrund der gleichzeitigen Analyse von morphologischen, funktionellen, quantitativen und metabolischen Parametern in einem Untersuchungsgang ein erfolgversprechendes Bildgebungsverfahren der Zukunft, da sie nicht invasiv ist, ohne Einsatz von Röntgenstrahlung auskommt und dabei eine gute räumliche Auflösung bei hohem Gewebekontrast bietet. Studien zeigen, dass die Kombination von Stress-Perfusion und Late-Technik in einem MRT-Protokoll eine höhere Genauigkeit als die Verwendung der SPECT-Untersuchung in der klinischen Beurteilung von Koronargefäßstenosen und im Nachweis subendokardialer Infarkte aufweist. 62 Allerdings erfährt die in vorliegender Arbeit verwendete Technik der Datenverarbeitung in dieser Form ohne Zweifel noch ihre Limitation im klinischen Alltag. Grundsätzlich ist zu sagen, dass die Messung der absoluten Perfusion im Myokard mit der MRT des Herzens zurzeit sicherlich noch nicht ausgereift ist. Dennoch lassen die in dieser Arbeit vorgestellten Ergebnisse und die viel versprechende Weiterentwicklung in der magnetresonanztomographischen Bildgebung weit reichende und interessante Möglichkeiten erahnen.
In der Diagnostik und Therapie der KHK ist die myokardiale Perfusion von immensem Interesse. Die verminderte Mikrozirkulation als funktionelle Folge einer Stenose korreliert mit den Beschwerden und der Prognose für einen Patienten mit KHK besser als die Morphologie der Stenose selbst. In der koronaren Angiographie wird die vaskuläre Situation der Herzkranzgefäße beurteilt und in Stenosegrade eingeteilt. Die Stenosen bedingen aber häufig nicht die entsprechende myokardiale Minderdurchblutung, sodass oft zusätzliche Untersuchungen der Ischämie-/Vitalitätsdiagnostik (z.B. Myokardszintigraphie, Stressechokardiographie) erforderlich sind.Im Gegensatz zu der bereits in der klinischen Routine eingesetzten Methode der MRT First-Pass Messungen, die meist nur qualitative Aussagen zur Myokardperfusion liefert, kann die hier untersuchte T1-Methode die Myokardperfusion quantitativ beschreiben. Mit der Spin Labeling Methode können T1-Werte nach globaler und schicht-selektiver Sättigung bestimmt werden. So lassen sich nach einem Zwei- Kompartimente-Modell Absolutwerte für die myokardiale Perfusion berechnen. In der vorliegenden Arbeit wurden gesunde Probanden und Patienten mit klinischem Hinweis auf KHK unter Ruhe und unter Adenosin vermittelter Vasodilatation untersucht. Ein definiertes Untersuchungsprotokoll sicherte die Vergleichbarkeit der Ergebnisse, die Dauer eines Messprotokolls betrug circa 45 Minuten. Bei den Messwerten der Probanden konnte eine T1-Verkürzung unter Vasodilatation nachgewiesen werden. Die Verkürzung der Relaxationszeit korreliert gut mit der Perfusionszunahme im Myokard. Im nächsten Schritt wurde an den untersuchten Patienten gezeigt, dass sich mit dieser Methode auch lokale Unterschiede in der myokardialen Perfusion nachweisen lassen. So wurde die koronare Flussreserve für Vorderwand und Hinterwand bestimmt. Des Weiteren wurden die Relaxationsraten dieser Segmente verglichen. Perfusionsdifferenzen für Patienten mit Ein-Gefäßerkrankungen konnten ebenso nachgewiesen werden, wie signifikante Unterschiede in den Relaxationsraten von Vorder- und Hinterwand bei Patienten mit der klinischen Diagnose KHK.