Vaccinia virus plays an important role in human medicine and molecular biology ever since the 18th century after E. Jenner discovered its value as a vaccination virus against smallpox. After the successful eradication of smallpox, vaccinia virus, apart from its use as a vaccine carrier, is today mainly used as a viral vector in molecular biology and increasingly in cancer therapy. The capability to specifically target and destroy cancer cells makes it a perfect agent for oncolytic virotherapy. Furthermore, the virus can easily be modified by inserting genes encoding therapeutic or diagnostic proteins to be expressed within the tumor. The emphasis in this study was the diagnosis of tumors using different vaccinia virus strains. Viruses with metal-accumulating capabilities for tumor detection via MRI technology were generated and tested for their usefulness in cell culture and in vivo. The virus strains GLV-1h131, GLV-1h132, and GLV-1h133 carry the gene encoding the two subunits of the iron storage protein ferritin under the control of three different promoters. GLV-1h110, GLV-1h111, and GLV-1h112 encode the bacterial iron storage protein bacterioferritin, whereas GLV-1h113 encodes the codon-optimized version of bacterioferritin for more efficient expression in human cells. GLV-1h22 contains the transferrin receptor gene, which plays an important role in iron uptake, and GLV-1h114 and GLV-1h115 contain the murine transferrin receptor gene. For possibly better iron uptake the virus strains GLV-1h154, GLV-1h155, GLV-1h156, and GLV-1h157 were generated, each with a version of a ferritin gene and a transferrin receptor gene. GLV-1h154 carries the genes that encode bacterioferritin and human transferrin receptor, GLV-1h155 the human ferritin H-chain gene and the human transferrin receptor gene. GLV-1h156 and GLV-1h157 infected cells both express the mouse transferrin receptor and bacterioferritin or human ferritin H-chain, respectively. The virus strains GLV-1h186 and GLV-1h187 were generated to contain a mutated form of the ferritin light chain, which was shown to result in iron overload and the wildtype light chain gene, respectively. The gene encoding the Divalent Metal Transporter 1, which is a major protein in the uptake of iron, was inserted in the virus strain GLV-1h102. The virus strain GLV-1h184 contains the magA gene of the magnetotactic bacterium Magnetospirillum magnetotacticum, which produces magnetic nanoparticles for orientation in the earth’s magnetic field. Initially the infection and replication capability of all the virus strains were analyzed and compared to that of the parental virus strain GLV-1h68, revealing that all the viruses were able to infect cells of the human cancer cell lines A549 and GI-101A. All constructs exhibited a course of infection comparable to that of GLV-1h68. Next, to investigate the expression of the foreign proteins in GI-101A and A549 cells with protein analytical methods, SDS-gelelectrophoresis, Western blots and ELISAs were performed. The proteins, which were expressed under the control of the strong promoters, could be detected using these methods. To be able to successfully detect the protein expression of MagA and DMT1, which were expressed under the control of the weak promoter, the more sensitive method RT-PCR was used to at least confirm the transcription of the inserted genes. The determination of the iron content in infected GI-101A and A549 cells showed that infection with all used virus strains led to iron accumulation in comparison to uninfected cells, even infection with the parental virus strain GLV-1h68. The synthetic phytochelatin EC20 was also shown to enhance the accumulation of different heavy metals in bacterial cultures. In vivo experiments with A549 tumor-bearing athymic nude mice revealed that 24 days post infection virus particles were found mainly in the tumor. The virus-mediated expression of recombinant proteins in the tumors was detected successfully by Western blot. Iron accumulation in tumor lysates was investigated by using the ferrozine assay and led to the result that GLV-1h68-infected tumors had the highest iron content. Histological stainings confirmed the finding that iron accumulation was not a direct result of the insertion of genes encoding iron-accumulating proteins in the virus genome. Furthermore virus-injected tumorous mice were analyzed using MRI technology. Two different measurements were performed, the first scan being done with a seven Tesla small animal scanner seven days post infection whereas the second scan was performed using a three Tesla human scanner 21 days after virus injection. Tumors of mice injected with the virus strains GLV-1h113 and GLV-1h184 were shown to exhibit shortened T2 and T2* relaxation times, which indicates enhanced iron accumulation. In conclusion, the experiments in this study suggest that the bacterioferritin-encoding virus strain GLV-1h113 and the magA-encoding virus strain GLV-1h184 are promising candidates to be used for cancer imaging after further analyzation and optimization.
Einleitung: Zwischen 1994-2003 wurden in Zusammenarbeit von HNO- und Neurochirurgie 615 Vestibularschwannome (Grad T3a-T4b) über den subokzipitalen Zugang operiert. In 89 Fällen (14%) konnte aus unterschiedlichen Gründen der Tumor nur inkomplett entfernt werden. Mittels neurologischer Untersuchung und MRT wurde postoperativ das funktionelle Ergebnis bzw. das Wachstumsverhalten des Resttumors untersucht. Außerdem wurden die Art des Resttumors und die Gründe für eine inkomplette Resektion analysiert. Material und Methoden: Alle Tumore wurden unter stetigem Neuromonitoring (AEP, Fazialis-EMG) operiert. Reichte der Tumor bis an die kaudalen Hirnnerven (IX, X, XI, XII) heran, wurden diese ebenfalls überwacht. In der postoperativen Kontrolle erfolgten eine neurologische Untersuchung und eine MRT. Die Ergebnisse wurden mit vorausgegangenen Untersuchungen verglichen, um das Wachstumsverhalten des Resttumors und das funktionelle Ergebnis zu beurteilen. Die Operationsberichte wurden nach den Gründen der inkompletten Tumorentfernung gesichtet. Ergebnisse: Starke Adhärenz des Tumorgewebes zu den Hirnnerven (VII, VIII, kaudale Gruppe) oder zum Hirnstamm, interfaszikuläre Tumornester, eine Gefährdung der Blutversorgung, spontane Entladungen im EMG oder eine reduzierte Ableitbarkeit der AEPs zwangen den Operateur, die Präparation abzubrechen. Die durchschnittliche Tumorgröße in den Fällen der inkompletten Resektion betrug 26,8 mm vs. 19,4 mm bei kompletter Tumorentfernung. Der zurückgelassene Tumorrest bestand in 86% aus einem Kapselanteil, einem Tumorrasen oder interfaszikulären Tumornestern. Grobe Tumorreste waren die Ausnahme. 12 Monate postoperativ wurde bei den Patienten mit kompletter Resektion in 88% eine gute bis sehr gute Funktionalität (House/Brackmann Grad I-II) des Gesichtsnervs beobachtet, bei inkompletter Tumorentfernung in 75%. 66% (n=59) der Resttumore zeigten keine Progredienz, 13% (n=12) eine Wachstumstendenz ohne klinische Symptomatik, 6% (n=5) mussten erneut operiert werden (15%/n=13 keine Kontrolle). Der durchschnittliche Nachbeobachtungszeitraum betrug 48,1 Monate (1-134). Zusammenfassung: Trotz Zurücklassens eines Tumorrestes kommt es nur selten zu einem erneuten Tumorwachstum. In noch weniger Fällen muss eine Rezidivoperation durchgeführt werden. Dies rechtfertigt eine subtotale Tumorresektion in den Fällen einer Hirnnervengefährdung. Verzichtet man auf eine komplette Resektion, lässt sich auch bei sehr großen Tumoren ein gutes bis sehr gutes funktionelles Ergebnis erzielen.
MRT-Untersuchungen des Herzens haben in den letzten Jahren an Häufigkeit und Bedeutung zugenommen. Die Nachfrage nach schnelleren und für den Patienten komfortableren Sequenzen steigt. Diese Arbeit untersucht, ob es mit Hilfe von parallelen Echtzeitsequenzen ohne EKG-Triggerung möglich ist, die Untersuchungszeit deutlich zu verkürzen und dabei gut reproduzierbare Messwerte zu erhalten. Hierzu wurden 9 Probanden und 21 Patienten mit A) paralleler Echtzeitbildgebung bei freier Atmung und B)einer Standard CINE Sequenz mit Atemstopp untersucht. Zur statistischen Analyse beider Methoden dienten Bland-Altman-Plots. Um Aussagen über die Reproduzierbarkeit der Ergebnisse treffen zu können wurde außerdem die Variabilität der Messungen bestimmt. Die Messzeit der neuen Echtzeitsequenz war um mehr als das zehnfache kürzer als die einer herkömmlichen CINE Sequenz. Die Ergebnisse waren mit der Standard CINE Sequenz vergleichbar und zeigten nur einen geringe Variabilität. Lediglich die linksventrikuläre Masse wurde im Gesamtkollektiv leicht überschätzt. Insgesamt scheint die Echtzeitbildgebung aufgrund der zuverlässigen Ergebnisse für den Klinikalltag geeignet. Insbesondere Patienten mit Atemnot, Herzrhythmusstörungen oder aber Kinder könnten profitieren.