The aim of the present work was to improve drug monitoring in patients with various diseases in the context of precision medicine. This was pursued through the development and validation of mass spectrometric methods for determining the drug concentrations of kinase inhibitors and their clinical application. Besides conventional approaches to determine plasma level concentrations, the focus was also on alternative sampling techniques using volumetric absorptive microsampling (VAMS).
A conventional LC-MS/MS method was developed for the determination of cabozantinib in human EDTA plasma and validated according to the guidelines of the European and United States drug authorities (EMA, FDA). The method met the required criteria for linearity, accuracy and precision, selectivity, sensitivity, and stability of the analyte. Validation was also performed for dilution integrity, matrix effect, recovery, and carry-over, with results also in accordance with the requirements. The importance of monitoring the exposure of cabozantinib was demonstrated by a clinical case report of a 34-year-old female patient with advanced adrenocortical carcinoma who also required hemodialysis due to chronic kidney failure. Expected cabozantinib plasma concentrations were simulated for this off-label use based on a population pharmacokinetic model. It was shown that the steady state trough levels were much lower than expected but could not be explained by hemodialysis. Considering the critical condition and potential drug-drug interaction with metyrapone, a substance the patient had taken among several others during the observation period, individual pharmacokinetics could consequently not be estimated without drug monitoring.
In addition, a VAMS method for simultaneous determination of ten kinase inhibitors from capillary blood was developed. This microsampling technique was mainly characterized by the collection of a defined volume of blood, which could be dried and subsequently analyzed. The guidelines for bioanalytical method validation of the EMA and FDA were also used for this evaluation. As the nature of dried blood samples differs from liquid matrices, further parameters were investigated. These include the investigation of the hematocrit effect, process efficiency, and various stability conditions, for example at increased storage temperatures. The validation showed that the developed method is suitable to analyze dried matrix samples accurate, precise, and selective for all analytes. Apart from the stability tests, all acceptance criteria were met. The decreased stability of two analytes was probably due to the reproducible but reduced recovery. In vitro studies provided results on the VAMS-to-plasma correlation to predict the analyte distribution between both matrices, at least in an exploratory manner. It revealed a heterogeneous picture of analytes with different VAMS-to-plasma distributions. Furthermore, the analysis of 24 patient samples indicated the applicability of at-home VAMS. Both should be confirmed later as part of the clinical validation.
The clinical investigation of the VAMS method pursued two objectives. On the one hand, the simultaneous collection of VAMS and serum samples should enable a conversion of the determined concentrations and, on the other hand, the feasibility of autonomous microsampling at home should be examined more closely. For the former, it could be shown that different conversion methods are suitable for converting VAMS concentrations into serum levels. The type of conversion was secondary for the prediction. However, the previously defined criteria could not be fulfilled for all five kinase inhibitors investigated. The framework conditions of the study led to increased variability, especially for analytes with short half-life. A low and varying hematocrit, caused by the underlying disease, also made prediction difficult for a specific patient collective. For the second objective, investigating the feasibility of VAMS, different aspects were considered. It could be shown that the majority of patients support home-based microsampling. The acceptance is likely to increase even further when microsampling is no longer part of a non-interventional study, but participation is accompanied by targeted monitoring and subsequent adjustment of the therapy. The fact that additional training increases understanding of the correct sampling procedure is also a source of confidence. Demonstrated stability during storage under real-life conditions underlines the practicality of this sampling technique.
Taken together, mass spectrometric methods for both plasma and VAMS could be developed and validated, and their clinical application could be successfully demonstrated. The availability of simple bioanalytical methods to determine kinase inhibitor exposure could improve access to prospective studies and thus facilitate the implementation of routine therapeutic drug monitoring.
Oral antineoplastic drugs are an important component in the treatment of solid tumour diseases, haematological and immunological malignancies. Oral drug administration is associated with positive features (e.g., non-invasive drug administration, outpatient care with a high level of independence for the patient and reduced costs for the health care system). The systemic exposure after oral intake however is prone to high IIV as it strongly depends on gastrointestinal absorption processes, which are per se characterized by high inter-and intraindividual variability. Disease and patient-specific characteristics (e.g., disease state, concomitant diseases, concomitant medication, patient demographics) may additionally contribute to variability in plasma concentrations between individual patients. In addition, many oral antineoplastic drugs show complex PK, which has not yet been fully investigated and elucidated for all substances. All this may increase the risk of suboptimal plasma exposure (either subtherapeutic or toxic), which may ultimately jeopardise the success of therapy, either through a loss of efficacy or through increased, intolerable adverse drug reactions. TDM can be used to detect suboptimal plasma levels and prevent permanent under- or overexposure. It is essential in the treatment of ACC with mitotane, a substance with unfavourable PK and high IIV. In the current work a HPLC-UV method for the TDM of mitotane using VAMS was developed. A low sample volume (20 µl) of capillary blood was used in the developed method, which facilitates dense sampling e.g., at treatment initiation. However, no reference ranges for measurements from capillary blood are established so far and a simple conversion from capillary concentrations to plasma concentrations was not possible. To date the therapeutic range is established only for plasma concentrations and observed capillary concentrations could not be reliable interpretated.The multi-kinase inhibitor cabozantinib is also used for the treatment of ACC. However, not all PK properties, like the characteristic second peak in the cabozantinib concentration-time profile have been fully understood so far. To gain a mechanistic understanding of the compound, a PBPK model was developed and various theories for modelling the second peak were explored, revealing that EHC of the compound is most plausible. Cabozantinib is mainly metabolized via CYP3A4 and susceptible to DDI with e.g., CYP3A4 inducers. The DDI between cabozantinib and rifampin was investigated with the developed PBPK model and revealed a reduced cabozantinib exposure (AUC) by 77%. Hence, the combination of cabozantinib with strong CYP inducers should be avoided. If this is not possible, co administration should be monitored using TDM. The model was also used to simulate cabozantinib plasma concentrations at different stages of liver injury. This showed a 64% and 50% increase in total exposure for mild and moderate liver injury, respectively.Ruxolitinib is used, among others, for patients with acute and chronic GvHD. These patients often also receive posaconazole for invasive fungal prophylaxis leading to CYP3A4 mediated DDI between both substances. Different dosing recommendations from the FDA and EMA on the use of ruxolitinib in combination with posaconazole complicate clinical use. To simulate the effect of this relevant DDI, two separate PBPK models for ruxolitinib and posaconazole were developed and combined. Predicted ruxolitinib exposure was compared to observed plasma concentrations obtained in GvHD patients. The model simulations showed that the observed ruxolitinib concentrations in these patients were generally higher than the simulated concentrations in healthy individuals, with standard dosing present in both scenarios. According to the developed model, EMA recommended RUX dose reduction seems to be plausible as due to the complexity of the disease and intake of extensive co-medication, RUX plasma concentration can be higher than expected.
Even though the international combat against Neglected Tropical Diseases such as schistosomiasis or soil-transmitted helminthiases depends on reliable therapeutics, anthelminthic pharmacovigilance has been neglected on many national African drug markets. Therefore, quality and composition of 88 different batches of Albendazole, Mebendazole and Praziquantel locally collected from randomly selected facilities in Western Burkina Faso, Southeast Côte d’Ivoire, Southwest Ghana and Northwest Tanzania were analysed.
Visual examination of both packaging and samples was performed according to the WHO ‘Be Aware’ tool. Products were then screened with the GPHF Minilab, consisting of tests of mass uniformity, disintegration times and thin-layer chromatography (TLC). Confirmatory tests were performed according to international pharmacopoeiae, applying assays for dissolution profiles and high-performance liquid chromatography (HPLC).
Despite minor irregularities, appearance of the products did not hint at falsified medicines. However, 19.6 % of the brands collected in Ghana and Tanzania were not officially licensed for sale. Mass uniformity was confirmed in 53 out of 58 brands of tablets. 41 out of 56 products passed disintegration times; 10 out of the 15 failing products did not disintegrate at all.
TLC results did not reveal any falsifications or pronounced dosing errors. HPLC findings confirmed the TLC results despite shifted specification limits: ten of the 83 tested batches contained less than 90 %, none more than 110 % label claim. However, no more than 46.3 % (31 / 67) of the tablet batches assayed passed the respective criteria for dissolution.
In the four study countries, no falsified anthelminthic medicine was encountered. The active pharmaceutical ingredient was not found to either exceed or distinctively fall below specification limits. Galenic characteristics as most critical criteria however, especially dissolution profiles, revealed substantial deficits.