Refine
Has Fulltext
- yes (31)
Is part of the Bibliography
- yes (31)
Year of publication
- 2015 (31) (remove)
Document Type
- Doctoral Thesis (31) (remove)
Keywords
- Kernspintomografie (9)
- Quecksilbertellurid (4)
- Topologischer Isolator (4)
- Exziton (3)
- Lunge (3)
- Biophysik (2)
- C60 (2)
- Diindenoperylen (2)
- Festkörperphysik (2)
- Gitterbaufehler (2)
- HgTe (2)
- Kondo-Effekt (2)
- Magnetische Kernresonanz (2)
- Organische Solarzelle (2)
- Photoelektronenspektroskopie (2)
- Photolumineszenz (2)
- RIXS (2)
- Rastertunnelmikroskop (2)
- topological insulator (2)
- 19F MR (1)
- 3 Tesla (1)
- 3D topological insulator (1)
- AC Gradients (1)
- ARPES (1)
- ASAXS (1)
- ATLAS <Teilchendetektor> (1)
- ATLAS-Detektor (1)
- AZO (1)
- Abschattung (1)
- Aminosäuren (1)
- Artefakt <Bildgebende Diagnostik> (1)
- B1 Mapping (1)
- Bakterielle Infektion (1)
- Bathophenanthrolin (1)
- Beschichtung (1)
- Bilagen-Solarzelle (1)
- Bloch Siegert (1)
- Bose-Einstein-Kondensation (1)
- CePt5 (1)
- Charakterisierung (1)
- CuPc (1)
- DC-Gating (1)
- Defektspektroskopie (1)
- Diamant (1)
- Diffusion (1)
- Dimensional Crossover (1)
- Dreidimensionale Bildverarbeitung (1)
- Drude model (1)
- Drude-Modell (1)
- Dünnschichtsolarzelle (1)
- Electrochemical energy storage (1)
- Elektrolumineszenz (1)
- Elektronenstruktur (1)
- Elektronische Eigenschaften (1)
- Elektronischer Transport (1)
- Energiespeicher (1)
- Exciton (1)
- Experimental physics (1)
- Exziton-Polariton (1)
- Exzitonen Diffusionslänge (1)
- Exzitonen Dynamik (1)
- Exzitonen Transport (1)
- Exzitonenbeweglichkeit (1)
- Feldstärkemessung (1)
- Femtosekunden Pulsformung (1)
- Femtosekundenbereich (1)
- Femtosekundenlaser (1)
- Funktionswerkstoff (1)
- Galliumarsenid (1)
- Geräuschminderung (1)
- Graphene (1)
- Grenzfläche (1)
- Halbleitergrenzflächen (1)
- Heterostruktur (1)
- Hochauflösendes Verfahren (1)
- Hochmagnetfeld (1)
- ITO (1)
- Implantat (1)
- Impulsformung (1)
- Infektionsbildgebung (1)
- Kohlenwasserstoffe (1)
- Kontrastmittel (1)
- Krach (1)
- Kristalloberfläche (1)
- LEED (1)
- LHC (1)
- Ladungsdichtewelle (1)
- Lautstärkereduktion (1)
- Lung Imaging (1)
- Lungenbildbgebung (1)
- Lungenfunktion (1)
- Lärm (1)
- Lärmbelastung (1)
- MBE (1)
- MRT der Lunge (1)
- Magnetfeld-Wechselwirkung (1)
- Magnetfeldsensor (1)
- Magnetic resonance (1)
- Magnetischer Röntgenzirkulardichroismus (1)
- Magnetometrie (1)
- Magnetresonanztomographie (1)
- Mercury Telluride (1)
- Metallimplantat (1)
- Mikroporosität (1)
- Mikrostruktur (1)
- Modellierung (1)
- Molekularstrahlepitaxie (1)
- Nanolithografie (1)
- Nanopartikel (1)
- Neue Physik (1)
- New physics (1)
- Nicht-kartesische Bildgebung (1)
- Non-Cartesian Imaging (1)
- ODMR-Spektroskopie (1)
- Oberfläche (1)
- Optical spectroscopy (1)
- Optische Spektroskopie (1)
- Optischer Resonator (1)
- Organische Halbleiter (1)
- Patientenkomfort (1)
- Perfluorkarbon (1)
- Pflanzen (1)
- Phasenumwandlung (1)
- Phonon (1)
- Photoanregung (1)
- Photoluminescence (1)
- Photolumineszenz Quenching (1)
- Photolumineszenzspektroskopie (1)
- Phthalocyanin (1)
- Physikalische Schicht (1)
- Polarisationspulsformung (1)
- Polariton (1)
- Polariton-Kondensation (1)
- Poröser Stoff (1)
- Proton-Proton-Streuung (1)
- Quanten-Hall-Effekt (1)
- Quantensensor (1)
- Quantenspinsystem (1)
- Radial Imaging (1)
- Radiale Bildgebung (1)
- Raman-Spektroskopie (1)
- Rashba-Effekt (1)
- Rastertunnelmikroskopie (1)
- Rekombination (1)
- Relaxation (1)
- Relaxationszeit (1)
- Retrospective Motion Compensation (1)
- Retrospektive Bewegungskorrektur (1)
- Ru(0001) (1)
- Ruthenium (1)
- Röntgenabsorptionsspektroskopie (1)
- Röntgenemission (1)
- Röntgenspektroskopie (1)
- SQUID (1)
- Salzlösung (1)
- Schwere-Fermionen-System (1)
- Siliciumcarbid (1)
- Silicon carbide (1)
- Silicon vacancy (1)
- Sol-Gel-Synthese (1)
- Sol-Gel-Verfahren (1)
- Solarzellen (1)
- Spektroskopische Flussmessung (1)
- Spin defect (1)
- Spin-Gitter-Relaxation (1)
- Spinpolarisierte Rastertunnelmikroskopie, Temperaturabhängige Phasenübergänge (1)
- Steady-State Sequences (1)
- Steady-State-Sequenzen (1)
- Steifigkeit (1)
- Step Ru surface (1)
- Supercapacitor (1)
- Superkondensator (1)
- Supersymmetrie (1)
- Supersymmetry (1)
- Supraleitung (1)
- T1-Relaxtion (1)
- T1-Wichtung (1)
- T2* (1)
- T2*-Relaxation (1)
- TI (1)
- Tieftemperatur (1)
- Tieftemperatur-Rastertunnelmikroskopie (1)
- Topological insulator (1)
- Transiente Absorptionsspektroskopie (1)
- Transparent-leitendes Oxid (1)
- Ulrakurze Echozeit (1)
- Ultrakurzer Lichtimpuls (1)
- Vektorfeldformer (1)
- Vektorfeldkontrolle (1)
- Verzerrung (1)
- Wassertransport (1)
- Wechselwirkung (1)
- Wärmeleitfähigkeit (1)
- Wärmeübertragung (1)
- Zahnmedizin (1)
- amino acids (1)
- aqueous solution (1)
- balanced SSFP (1)
- bathophenanthroline (1)
- dichteangepasste k-Raum Abtastung (1)
- diindenoperylene (1)
- electronic structure (1)
- exciton blocking layer (1)
- femtosecond pulse shaping (1)
- free breathing (1)
- freie Atmung (1)
- funktionelle Lungenbildgebung (1)
- induced (1)
- insulator (1)
- inverse photoemission (1)
- josephson junction (1)
- mechanical stiffness (1)
- mechanische Steifigkeit (1)
- mercury (1)
- microstructure (1)
- nanolithography (1)
- nicht-diagonale langreichweitige Ordnung (1)
- photoelectron spectroscopy (1)
- physics (1)
- polarization pulse shaping (1)
- porous (1)
- porös (1)
- proximity effect (1)
- quantum point contact (1)
- redispergierte Nanopartikel-Sole (1)
- redispersed nanoparticle sol (1)
- resonant inelastic x-ray scattering (1)
- salt solutions (1)
- semiconductor (1)
- semiconductor interfaces (1)
- single-crystalline Ru surfaces (1)
- sol gel (1)
- spin (1)
- spinpolarized scanning tunneling microscopy, temperature dependent phase transitions (1)
- superconductivity (1)
- telluride (1)
- thermal conductivity (1)
- topological (1)
- vacancy (1)
- vector-field control (1)
- vector-field shaper (1)
- x-ray emission (1)
- Übergitter (1)
Institute
- Physikalisches Institut (31) (remove)
Sonstige beteiligte Institutionen
In the present thesis the MBE growth and sample characterization of HgTe structures is investigated
and discussed. Due to the first experimental discovery of the quantum Spin Hall effect
(QSHE) in HgTe quantum wells, this material system attains a huge interest in the spintronics
society. Because of the long history of growing Hg-based heterostructures here at the Experimentelle
Physik III in Würzburg, there are very good requirements to analyze this material
system more precisely and in new directions. Since in former days only doped HgTe quantum
wells were grown, this thesis deals with the MBE growth in the (001) direction of undoped
HgTe quantum wells, surface located quantum wells and three dimensional bulk layers. All
Hg-based layers were grown on CdTe substrates which generate strain in the layer stack and
provide therefore new physical effects. In the same time, the (001) CdTe growth was investigated
on n-doped (001) GaAs:Si because the Japanese supplier of CdTe substrates had a
supply bottleneck due to the Tohoku earthquake and its aftermath in 2011.
After a short introduction of the material system, the experimental techniques were demonstrated
and explained explicitly. After that, the experimental part of this thesis is displayed.
So, the investigation of the (001) CdTe growth on (001) GaAs:Si is discussed in chapter 4.
Firstly, the surface preparation of GaAs:Si by oxide desorption is explored and analyzed.
Here, rapid thermal desorption of the GaAs oxide with following cool down in Zn atmosphere
provides the best results for the CdTe due to small holes at the surface, while e.g. an atomic
flat GaAs buffer deteriorates the CdTe growth quality. The following ZnTe layer supplies the
(001) growth direction of the CdTe and exhibits best end results of the CdTe for 30 seconds
growth time at a flux ratio of Zn/Te ~ 1/1.2. Without this ZnTe layer, CdTe will grow in the
(111) direction. However, the main investigation is here the optimization of the MBE growth
of CdTe. The substrate temperature, Cd/Te flux ratio and the growth time has to be adjusted
systematically. Therefore, a complex growth process is developed and established. This optimized
CdTe growth process results in a RMS roughness of around 2.5 nm and a FWHM value
of the HRXRD w-scan of 150 arcsec. Compared to the literature, there is no lower FWHM
value traceable for this growth direction. Furthermore, etch pit density measurements show
that the surface crystallinity is matchable with the commercial CdTe substrates (around 1x10^4
cm^(-2)). However, this whole process is not completely perfect and offers still room for improvements.
The growth of undoped HgTe quantum wells was also a new direction in research in contrast
to the previous n-doped grown HgTe quantum wells. Here in chapter 5, the goal of very low
carrier densities was achieved and therefore it is now possible to do transport experiments in
the n - and p - region by tuning the gate voltage. To achieve this high sample quality, very precise
growth of symmetric HgTe QWs and their HRXRD characterization is examined. Here,
the quantum well thickness can now determined accurate to under 0.3 nm. Furthermore, the transport analysis of different quantum well thicknesses shows that the carrier density and
mobility increase with rising HgTe layer thickness. However, it is found out that the band
gap of the HgTe QW closes indirectly at a thickness of 11.6 nm. This is caused by the tensile
strained growth on CdTe substrates. Moreover, surface quantum wells are studied. These
quantum wells exhibit no or a very thin HgCdTe cap. Though, oxidization and contamination
of the surface reduces here the carrier mobility immensely and a HgCdTe layer of around 5 nm
provides the pleasing results for transport experiments with superconductors connected to the
topological insulator [119]. A completely new achievement is the realization of MBE growth
of HgTe quantum wells on CdTe/GaAs:Si substrates. This is attended by the optimization of
the CdTe growth on GaAs:Si. It exposes that HgTe quantum wells grown in-situ on optimized
CdTe/GaAs:Si show very nice transport data with clear Hall plateaus, SdH oscillations, low
carrier densities and carrier mobilities up to 500 000 cm^2/Vs. Furthermore, a new oxide etching
process is developed and analyzed which should serve as an alternative to the standard
HCl process which generates volcano defects at some time. However, during the testing time
the result does not differ in Nomarski, HRXRD, AFM and transport measurements. Here,
long-time tests or etching and mounting in nitrogen atmosphere may provide new elaborate
results.
The main focus of this thesis is on the MBE growth and standard characterization of HgTe bulk
layers and is discussed in chapter 6. Due to the tensile strained growth on lattice mismatched
CdTe, HgTe bulk opens up a band gap of around 22 meV at the G-point and exhibits therefore
its topological surface states. The analysis of surface condition, roughness, crystalline quality,
carrier density and mobility via Nomarski, AFM, XPS, HRXRD and transport measurements
is therefore included in this work. Layer thickness dependence of carrier density and mobility
is identified for bulk layer grown directly on CdTe substrates. So, there is no clear correlation
visible between HgTe layer thickness and carrier density or mobility. So, the carrier density is
almost constant around 1x10^11 cm^(-2) at 0 V gate voltage. The carrier mobility of these bulk
samples however scatters between 5 000 and 60 000 cm^2/Vs almost randomly. Further experiments
should be made for a clearer understanding and therefore the avoidance of unusable
bad samples.But, other topological insulator materials show much higher carrier densities and
lower mobility values. For example, Bi2Se3 exhibits just density values around 1019 cm^(-2)
and mobility values clearly below 5000 cm2/Vs. The carrier density however depends much
on lithography and surface treatment after growth. Furthermore, the relaxation behavior and
critical thickness of HgTe grown on CdTe is determined and is in very good agreement with
theoretical prediction (d_c = 155 nm). The embedding of the HgTe bulk layer between HgCdTe
layers created a further huge improvement. Similar to the quantum well structures the carrier
mobility increases immensely while the carrier density levels at around 1x10^11 cm^(-2) at 0
V gate voltage as well. Additionally, the relaxation behavior and critical thickness of these
barrier layers has to be determined. HgCdTe grown on commercial CdTe shows a behavior as
predicted except the critical thickness which is slightly higher than expected (d_c = 850 nm).
Otherwise, the relaxation of HgCdTe grown on CdTe/GaAs:Si occurs in two parts. The layer
is fully strained up to 250 nm. Between 250 nm and 725 nm the HgCdTe film starts to relax
randomly up to 10 %. The relaxation behavior for thicknesses larger than 725 nm occurs than
linearly to the inverse layer thickness. A explanation is given due to rough interface conditions
and crystalline defects of the CdTe/GaAs:Si compared to the commercial CdTe substrate. HRXRD and AFM data support this statement. Another point is that the HgCdTe barriers protect the active HgTe layer and because of the high carrier mobilities the Hall measurements provide new transport data which have to be interpreted more in detail in the future. In addition, HgTe bulk samples show very interesting transport data by gating the sample from the top and the back. It is now possible to manipulate the carrier densities of the top and bottom surface states almost separately. The back gate consisting of the n-doped GaAs substrate and the thick insulating CdTe buffer can tune the carrier density for Delta(n) ~ 3x10^11 cm^(-2). This is sufficient to tune the Fermi energy from the p-type into the n-type region [138].
In this thesis it is shown that strained HgTe bulk layers exhibit superior transport data by embedding between HgCdTe barrier layers. The n-doped GaAs can here serve as a back gate.
Furthermore, MBE growth of high crystalline, undoped HgTe quantum wells shows also new
and extended transport output. Finally, it is notable that due to the investigated CdTe growth
on GaAs the Hg-based heterostructure MBE growth is partially independent from commercial
suppliers.
In der vorliegenden Arbeit wird die Rotated-Cone-UTE-Sequenz (RC-UTE), eine 3D k-Raum-Auslesetechnik mit homogener Verteilung der Abtastdichte, vorgestellt. Diese 3D MR-Messtechnik ermöglicht die für die Detektion von schnell abfallenden Signalen notwendigen kurzen Echozeiten und weist eine höhere SNR-Effizienz als konventionelle radiale Pulssequenzen auf. Die Abtastdichte ist dabei in radialer und azimutaler Richtung angepasst. Simulationen und Messungen in vivo zeigen, dass die radiale Anpassung das T2-Blurring reduziert und die SNR-Effizienz erhöht. Die Drehung der Trajektorie in azimutale Richtung ermöglicht die Reduzierung der Unterabtastung bei gleicher Messzeit bzw. eine Reduzierung der Messzeit ohne Auflösungsverlust.
Die RC-UTE-Sequenz wurde erfolgreich für die Bildgebung des Signals des kortikalen Knochens und der Lunge in vivo angewendet. Im Vergleich mit der grundlegenden UTE-Sequenz wurden die Vorteile von RC-UTE in allen Anwendungsbeispielen aufgezeigt. Die transversalen Relaxationszeit T2* des kortikalen Knochen bei einer Feldstärke von 3.0T und der Lunge bei 1.5T und 3.0T wurde in 3D isotroper Auflösung gemessen. Außerdem wurde die Kombination von RC-UTE-Sequenz mit Methoden der Magnetisierungspräparation zur besseren Kontrasterzeugung gezeigt. Dabei wurden die Doppel-Echo-Methode, die Unterdrückung von Komponenten mit langer Relaxationszeit T2 durch Inversionspulse und der Magnetisierungstransfer-Kontrast angewendet.
Die Verwendung der RC-UTE-Sequenz für die 3D funktionelle Lungenbildgebung wird ebenfalls vorgestellt. Mit dem Ziel der umfassenden Charakterisierung der Lungenfunktion in 3D wurde die simultane Messung T1-gewichteter Bilder und quantitativer T2*-Karten für verschiedene Atemzustände an sechs Probanden durchgeführt. Mit der hier vorgestellten Methode kann die Lungenfunktion in 3D über T1-Wichtung, quantitative T2*-Messung und Rekonstruktion verschiedener Atemzustände durch Darstellung von Ventilation, Sauerstofftransport und Volumenänderung beurteilt werden.
The controlled shaping of ultrashort laser pulses is a powerful technology and applied in many laser laboratories today. Most of the used pulse shapers are only able to produce linearly polarized pulses shaped in amplitude and phase. Some devices are also capable of producing limited time-varying polarization profiles, but they are not able to control the amplitude. However, for some state-of-the-art non-linear time-resolved methods, such as polarization-enhanced two-dimensional spectroscopy, the possibility of controlling the amplitude and the polarization simultaneously is desirable.
Over the last years, different concepts have been developed to overcome these restrictions and to manipulate the complete vector-field of an ultrashort laser pulse with independent control over all four degrees of freedom - phase, amplitude, orientation, and ellipticity. The aim of this work was to build such a vector-field shaper. While the basic concept used for our setup is based on previous designs reported in the literature, the goal was to develop an optimized optical design that minimizes artifacts, allowing for the generation of predefined polarization pulse sequences with the highest achievable accuracy.
In Chapter 3, different approaches reported in the literature for extended and unrestricted vector-field control were examined and compared in detail. Based on this analysis, we decided to follow the approach of modulating the spectral phase and amplitude of two perpendicularly polarized pulses independently from each other in two arms of an interferometer and recombining them to a single laser pulse to gain control over the complete vector field.
As described in Chapter 4, the setup consists of three functional groups: i) an optical component to generate and recombine the two polarized beams, ii) a 4f setup, and iii) a refracting telescope to direct the two beams under two different angles of incidence onto the grating of the 4f setup in a common-path geometry. This geometry was chosen to overcome potential phase instabilities of an interferometric vector-field shaper. Manipulating the two perpendicularly polarized pulses simultaneously within one 4f setup and using adjacent pixel groups of the same liquid-crystal spatial light modulator (LC SLM) for the two polarizations has the advantages that only a single dual-layer LC SLM is required and that a robust and compact setup was achieved. The shaping capabilities of the presented design were optimized by finding the best parameters for the setup through numerical calculations to adjust the frequency distributions for a broad spectrum of 740 – 880 nm. Instead of using a Wollaston prism as in previous designs, a thin-film polarizer (TFP) is utilized to generate and recombine the two orthogonally polarized beams. Artifacts such as angular dispersion and phase distortions along the beam profile which arise when a Wollaston prism is used were discussed. Furthermore, it was shown by ray-tracing simulations that in combination with a telescope and the 4f setup, a significant deformation of the beam profile would be present when using a Wollaston prism since a separation of the incoming and outgoing beam in height is needed. The ray-tracing simulations also showed that most optical aberrations of the setup are canceled out when the incoming and outgoing beams propagate in the exact same plane by inverting the beam paths. This was realized by employing a TFP in the so-called crossed-polarizer arrangement which has also the advantage that the polarization-dependent efficiencies of the TFP and the other optics are automatically compensated and that a high extinction ratio in the order of 15000:1 is reached. Chromatic aberrations are, however, not compensated by the crossed-polarizer arrangement. The ray-tracing simulations confirmed that these chromatic aberrations are mainly caused by the telescope and not by the cylindrical lens of the 4f setup. Nevertheless, in the experimentally used wavelength range of 780 – 816 nm, only minor distortions of the beam profile were observed, which were thus considered to be negligible in the presented setup.
The software implementation of the pulse shaper was reviewed in Chapter 5 of this thesis. In order to perform various experiments, five different parameterizations, accounting for the extended shaping capabilities of a vector-field shaper, were developed. The Pixel Basis, the Spectral Basis, and the Spectral Taylor Basis can generally be used in combination with an optimization algorithm and are therefore well suited for quantum control experiments. For multidimensional spectroscopy, the Polarized Four-Pulse Basis was established. With this parameterization pulse sequences with up to four subpulses can be created. The polarization state of each subpulse can be specified and the relative intensity, phase, and temporal delay between consecutive subpulses can be controlled. In addition, different software programs were introduced in Chapter 5 which are required to perform the experiments conducted in this work.
The experimental results were presented in Chapter 6. The frequency distribution across the LC SLM was measured proving that the optimal frequency distribution was realized experimentally. Furthermore, the excellent performance of the TFP was verified. In general, satellite pulses are emitted from the TFP due to multiple internal reflections. Various measurements demonstrated that these pulses are temporally separated by at least 4.05 ps from the main pulse and that they have vanishing intensity. The phase stability between the two arms of the presented common-path setup σ = 28.3 mrad (λ/222) over 60 minutes. To further improve this stability over very long measurement times, an on-the-fly phase reduction and stabilization (OPRAS) routine utilizing the pulse shaper itself was developed. This routine automatically produces a compressed pulse with a minimized relative phase between the two polarization components. A phase stability of σ = 31.9 mrad (λ/197) over nearly 24 hours was measured by employing OPRAS. Various pulse sequences exceeding the capabilities of conventional pulse shapers were generated and characterized. The experimental results proved that shaped pulses with arbitrary phase, amplitude, and polarization states can be created. In all cases very high agreement between the target parameters and the experimental data was achieved.
For the future use of the setup also possible modifications were suggested. These are not strictly required, but all of them could further improve the performance and flexibility of the setup. Firstly, it was illustrated how a “dual-output” of the setup can be realized. With this modification it would be possible to use the main intensity of the shaped pulse for an experiment while using a small fraction to characterize the pulse or to perform OPRAS simultaneously. Secondly, the basic idea of replacing the telescope by focusing mirrors in order to eliminate the chromatic aberrations was presented. Regarding the different parameterizations for vector-field shaping, some modifications increasing the flexibility of the implemented bases and the realization of a von Neumann Basis for the presented setup were proposed. In future experiments, the vector-field shaper will be used in conjunction with a photoemission electron microscope (PEEM). This approach combines the temporal resolution provided by ultrashort laser pulses with the high spatial resolution gained by electron microscopy in order to perform two-dimensional spectroscopy and coherent control on nanostructures with polarization-shaped femtosecond laser pulses. In combination with other chiral-sensitive experimental setups implemented earlier in our group, the vector-field shaper opens up new perspectives for chiral femtochemistry and chiral control.
The designed vector-field shaper meets all requirements to generate high-precision polarization-shaped multipulse sequences. These can be used to perform numerous polarization-sensitive experiments. Employing the OPRAS routine, a quasi-infinitely long phase stability is achieved and complex and elaborated long-term measurements can be carried out. The fact that OPRAS demands no additional hardware and that only a single dual-layer LC SLM and inexpensive optics are required allows the building of a vector-field shaper at comparatively low costs. We hope that with the detailed insights into the optical design process as well as into the software implementation given in this thesis, vector-field shaping will become a standard technique just as conventional pulse shaping in the upcoming years.
Kohärenz- und Magnetfeldmessungen an Polariton-Kondensaten unterschiedlicher räumlicher Dimensionen
(2015)
Die Bose-Einstein-Kondensation (BEK) und die damit verbundenen Effekte wie Superfluidität und Supraleitung sind faszinierende Resultate der Quantennatur von Bosonen. Nachdem die Bose-Einstein-Kondensation für Atom-Systeme nur bei Temperaturen nahe dem absoluten Nullpunkt realisierbar ist, was einen enormen technologischen Aufwand benötigt, wurden Bosonen mit wesentlich kleineren Massen zur Untersuchung der BEK gesucht. Hierfür bieten sich Quasiteilchen in Festkörpern wie Magnonen oder Exzitonen an, da deren effektive Massen sehr klein sind und die Kondensationstemperatur dementsprechend höher ist als für ein atomares System. Ein weiteres Quasiteilchen ist das Exziton-Polariton als Resultat der starken Licht-Materie-Wechselwirkung in Halbleitermikrokavitäten, welches sowohl Materie- als auch Photoneigenschaften hat und dessen Masse theoretisch eine BEK bis Raumtemperatur erlaubt. Ein weiterer Vorteil dieses System ist die einfache Erzeugung des Bose-Einstein-Kondensats in diesen Systemen durch elektrisches oder optisches Injizieren von Exzitonen in die Halbleiter-Quantenfilme der Struktur. Außerdem kann die Impulsraumverteilung dieser Quasiteilchen leicht durch einfache experimentelle Methoden mittels eines Fourierraumspektroskopie-Aufbaus bestimmt werden. Durch die winkelabhängige Messung der Emission kann direkt auf die Impulsverteilung der Exziton-Polaritonen in der Quantenfilmebene zurückgerechnet werden, die zur Identifikation der BEK hilfreich ist. Deshalb wird das Exziton-Polariton als ein Modellsystem für die Untersuchung von Bose-Einstein-Kondensation in Festkörpern und den damit in Relation stehenden Effekten angesehen. In dieser Arbeit wird die Grundzustandskondensation von Exziton-Polaritonen in Halbleitermikrokavitäten verschiedener Dimensionen realisiert und deren Emissionseigenschaften untersucht. Dabei wird vor allem die Wechselwirkung des Polariton-Kondensats mit der der unkondensierten Polaritonen bzw. der Quantenfilm-Exzitonen im externen Magnetfeld verglichen und ein Nachweis zum Erhalt der starken Kopplung über die Polariton-Kondensationsschwelle hinaus entwickelt. Außerdem werden die Kohärenzeigenschaften von null- und eindimensionalen Polariton-Kondensaten durch Bestimmung der Korrelationsfunktion erster beziehungsweise zweiter Ordnung analysiert. Als Materialsystem werden hierbei die III/V-Halbleiter gewählt und die Quantenfilme bestehen bei allen Messungen aus GaAs, die von einer AlAs Kavität umgeben sind.
Eindimensionale Polariton-Kondensation - räumliche Kohärenz der Polariton-Drähte
Im ersten experimentellen Teil dieser Arbeit (Kapitel 1) wird die Kondensation der Polaritonen in eindimensionalen Drähten unter nicht-resonanter optischer Anregung untersucht. Dabei werden verschiedene Drahtlängen und -breiten verwendet, um den Einfluss des zusätzlichen Einschlusses auf die Polariton-Dispersion bestimmen zu können. Ziel dieser Arbeit ist es, ein eindimensionales Bose-Einstein-Kondensat mit einer konstanten räumlichen Kohärenz nach dem zentralen Abfall der g^(1)(r)-Funktion für große Abstände r in diesen Drähten zu realisieren (sogenannte langreichweitige Ordnung im System, ODLRO (Abkürzung aus dem Englischen off-diagonal long-range order).
Durch Analyse der Fernfeldemissionseigenschaften können mehrere Polariton-Äste, der eindimensionale Charakter und die Polariton-Kondensation in 1D-Systemen nachgewiesen werden. Daraufhin wird die räumliche Kohärenzfunktion g^(1)(r) mithilfe eines hochpräzisen Michelson-Interferometer, das im Rahmen dieser Arbeit aufgebaut wurde, bestimmt. Die g^(1)(r)-Funktion nimmt hierbei über große Abstände im Vergleich zur thermischen De-Broglie-Wellenlänge einen konstanten Plateauwert an, der abhängig von der Anregungsleistung ist. Unterhalb der Polariton-Kondensationsschwelle (Schwellleistung P_S) ist kein Plateau sichtbar und die räumliche Kohärenz ist nur im zentralen Bereich von unter |r| < 1 µm vorhanden. Mit ansteigender Anregungsleistung nimmt das zentrale Maximum in der Weite zu und es bildet sich das Plateau der g^(1)(r)-Funktion aus, das nur außerhalb des Drahtes auf Null abfällt. Bei P=1,6P_S ist das Plateau maximal und beträgt circa 0,15. Außerdem kann nachgewiesen werden, dass mit steigender Temperatur die Plateauhöhe abnimmt und schließlich bei T=25K nicht mehr gemessen werden kann. Hierbei ist dann nur noch das zentrale Maximum der Kohärenzfunktion g^(1)(r) sichtbar. Weiterhin werden die Ergebnisse mit einer modernen mikroskopischen Theorie, die auf einem stochastischen Mastergleichungssystem basiert, verglichen, wodurch die experimentellen Daten reproduziert werden können. Im letzten Teil des Kapitels wird noch die Kohärenzfunktion g^(1)(r) im 1D-Fall mit der eines planaren Polariton-Kondensats verglichen (2D).
Nulldimensionale Polariton-Kondensation - Kondensation und Magnetfeldwechselwirkung in einer Hybridkavität
Im zweiten Teil der Arbeit wird die Polariton-Kondensation in einer neuartigen Hybridkavität untersucht. Der Aufbau des unteren Spiegels und der Kavität inklusive der 12 verwendeten Quantenfilme ist analog zu den gewöhnlichen Mikrokavitäten auf Halbleiterbasis. Der obere Spiegel jedoch besteht aus einer Kombination von einem DBR (Abkürzung aus dem Englischen distributed Bragg reflector) und einem Brechungsindexkontrast-Gitter mit einem Luft-Halbleiterübergang (größt möglichster Brechungsindexkontrast). Durch die quadratische Strukturgröße des Gitters (Seitenlänge 5µm) sind die Polaritonen zusätzlich zur Wachstumsrichtung noch in der Quantenfilmebene eingesperrt, so dass sie als nulldimensional angesehen werden können (Einschluss auf der ungefähren Größe der thermischen De-Broglie-Wellenlänge). Um den Erhalt der starken Kopplung über die Kondensationsschwelle hinaus nachweisen zu können, wird ein Magnetfeld in Wachstumsrichtung angelegt und die diamagnetische Verschiebung des Quantenfilms mit der des 0D-Polariton-Kondensats verglichen. Hierdurch kann das Polariton-Kondensat von dem konventionellen Photonlasing in solchen Strukturen unterschieden werden. Weiterhin wird als letztes Unterscheidungsmerkmal zwischen Photonlasing und Polariton-Kondensation eine Messung der Autokorrelationsfunktion zweiter Ordnung g^(2)(t) durchgeführt. Dabei kann ein Wiederanstieg des g^(2)(t = 0)-Werts mit ansteigender Anregungsleistung nachgewiesen werden, nachdem an der Kondensationsschwelle der g^(2)(t = 0)-Wert auf 1 abgefallen ist, was auf eine zeitliche Kohärenzzunahme im System hinweist. Oberhalb der Polariton-Kondensationsschwelle P_S steigt der g^(2)(t = 0)-Wert wieder aufgrund zunehmender Dekohärenzprozesse, verursacht durch die im System ansteigende Polariton-Polariton-Wechselwirkung, auf Werte größer als 1 an. Für einen gewöhnlichen Photon-Laser (VCSEL, Abkürzung aus dem Englischen vertical-cavity surface-emitting laser) im monomodigen Betrieb kann mit steigender Anregungsleistung kein Wiederanstieg des g^(2)(t = 0)-Werts gemessen werden. Somit stellt dies ein weiteres Unterscheidungsmerkmal zwischen Polariton-Kondensation und Photonlasing dar.
Zweidimensionale Polariton-Kondensation - Wechselwirkung mit externem Magnetfeld
Im letzten experimentellen Kapitel dieser Arbeit wird die Magnetfeldwechselwirkung der drei möglichen Regime der Mikrokavitätsemission einer planaren Struktur (zweidimensional) untersucht. Dazu werden zuerst durch eine Leistungsserie bei einer Verstimmung des Photons und des Quantenfilm-Exzitons von d =-6,5meV das lineare, polaritonische Regime, das Polariton-Kondensat und bei weiterer Erhöhung der Anregungsleistung das Photonlasing identifiziert. Diese drei unterschiedlichen Regime werden daraufhin im Magnetfeld von B=0T-5T auf ihre Zeeman-Aufspaltung und ihre diamagnetische Verschiebung untersucht und die Ergebnisse der Magnetfeldwechselwirkung werden anschließend miteinander verglichen. Im linearen Regime kann die Abhängigkeit der Zeeman-Aufspaltung und der diamagnetischen Verschiebung vom exzitonischen Anteils des Polaritons bestätigt werden. Oberhalb der Polariton-Kondensationsschwelle wird eine größere diamagnetische Verschiebung gemessen als für die gleiche Verstimmung im linearen Regime. Dieses Verhalten wird durch Abschirmungseffekte der Coulomb-Anziehung von Elektronen und Löchern erklärt, was in einer Erhöhung des Bohrradius der Exzitonen resultiert. Auch die Zeeman-Aufspaltung oberhalb der Polariton-Kondensationsschwelle zeigt ein vom unkondensierten Polariton abweichendes Verhalten, es kommt sogar zu einer Vorzeichenumkehr der Aufspaltung im Magnetfeld. Aufgrund der langen Spin-Relaxationszeiten von 300ps wird eine Theorie basierend auf der im thermischen Gleichgewichtsfall entwickelt, die nur ein partielles anstatt eines vollständigen thermischen Gleichgewicht annimmt. So befinden sich die einzelnen Spin-Komponenten im Gleichgewicht, während zwischen den beiden Spin-Komponenten kein Gleichgewicht vorhanden ist. Dadurch kann die Vorzeichenumkehr als ein Zusammenspiel einer dichteabhängigen Blauverschiebung jeder einzelner Spin-Komponente und der Orientierung der Spins im Magnetfeld angesehen werden. Für das Photonlasing kann keine Magnetfeldwechselwirkung festgestellt werden, wodurch verdeutlicht wird, dass die Messung der Zeeman-Aufspaltung beziehungsweise der diamagnetischen Verschiebung im Magnetfeld als ein eindeutiges Werkzeug zur Unterscheidung zwischen Polariton-Kondensation und Photonlasing verwendet werden kann.
Im Rahmen dieser Arbeit sollten die Möglichkeiten der MR Tomographie erkundet werden bakterielle Infektionen im Zeitverlauf darzustellen. Genauer gesagt sollte das Potential der MR Tomographie anhand eines durch eine Infektion induzierten lokalisierten Abszesses unter Verwendung dreier unterschiedlicher MRT Methoden untersucht werden: Mittels nativem \(T_2\) Kontrast; der Verwendung von superparamagnetischen Eisenoxid Partieln (USPIO) als \(T_2^*\) Kontrastmittel; und dem Einsatz von Perfluorkarbonen (PFC) als \(^{19}F\) MRT Marker (siehe Kapitel 3).
Wie erwartet führte die durch die Infektion hervorgerufene Entzündung zu veränderten \(T_2\)-Zeiten, welche auf \(T_2\)-gewichteten MR Bildern eine Lokalisierung des Abszessbereiches erlauben. Jedoch eigneten sich diese Daten aufgrund der graduellen Änderung der \(T_2\)-Zeiten nicht, um eine klare Grenze zwischen Abszess und umliegendem Gewebe zu ziehen.
Superparamagnetische Eisenoxidpartikel andererseit haben als MRT Kontrastmittel bereits in den letzten Jahren ihre Fähigkeit unter Beweis gestellt Entzündungen [53, 58, 64] darzustellen. Die Anreicherung dieser Partikel am Rande des Abszesses [53], wie sie auch in unseren MR Daten zu beobachten war, erlaubte eine relativ scharfe Abgrenzung gegenüber dem umgebenden Gewebe in der chronischen Phase der Infektion (Tag 9 p.i.). Hingegen genügte die nur sehr spärlichen Anreicherung von USPIO Partikeln in der akuten Phase der Infektion (Tag 3 p.i.) nicht für eine entsprechende Abgrenzung [58].
Aufgrund der sehr geringen biologischen Häufigkeit und den sehr kurzen Relaxationszeiten von endogenem Fluor eignen sich Perfluorkarbone als Markersubstanz in der MR Tomographie von biologischen Systemen. Insbesondere da PFC Emulsionen durch phagozytierende Zellen aufgenommen werden und im Bereich von Entzündungen akkumulieren [30, 59]. In dieser Arbeit konnte anhand der erhaltenen MRT Daten eine Akkumulation von Perfluorkarbonen nicht nur in der chronischen Phase, sondern auch in der akuten Phase nachgewiesen werden. Diese Daten erlauben somit zu allen untersuchten Zeitpunkten eine Abgrenzung zwischen Infektion und umliegenden Gewebe.
Aufgrund der besagten Vorteile wurden die Perfluorkarbone gewählt, um die Möglichkeiten der MR Tomographie zu testen, quantitative Informationen über die schwere der Infektion zu liefern. Als Referenz für die Bakterienbelastung wurden die Biolumineszenzbildgebung (BLI) [49, 50] und die Standardmethode zur Bestimmung der Bakterienbelastung cfu (koloniebildenden Einheiten) herangezogen. Eine Gegenüberstellung der zeitlichen Verläufe der durch die Biolumineszenzbildgebung und durch die cfu erhaltenen Daten liefert eine qualitative Übereinstimmung mit den durch die 19F MR Tomographie erhaltenen Daten. Dies trifft hierbei sowohl auf die über den gesamten Infektionsbereich hinweg summierten Signalamplituden, als auch auf das Volumen zu, in dem Fluor am Ort der Infektion akkumuliert wurde. Im Gegensatz zur Methode der cfu Bestimmung sind die MR Tomographie und die Biolumineszenzbildgebung nicht invasiv und erlauben die Verfolgung des Infektionsverlaufes an einem einzelnen Individuum. Hierzu benötigt, im Gegensatz zur MR Tomographie, die Methode der Biolumineszenzbildgebung jedoch einen speziellen Pathogenstamm. Darüber hinaus ist hervorzuheben, dass die MR Tomographie zudem die Möglichkeit bietet auch morphologische Informationen über den Infektionsbereich und seine Umgebung zu akquirieren.
Gerade weil jede dieser Methoden die mit der Infektion einhergehenden Prozesse aus einer leicht anderen Blickrichtung betrachtet, erscheint es sinnvoll diese etablierte Untersuchungsplattform bestehend aus MRT, BLI und cfu über die in dieser Arbeit bearbeitete Fragestellung hinaus näher zu untersuchen. Insbesondere der Aspekt inwieweit die drei Methoden sich gegenseitig ergänzen, könnte einen tieferen Einblick in die Wechselwirkung zwischen Pathogen und Wirt erlauben.
Auch wenn für die betrachtete Fragestellung bereits der hierdurchgeführte semiquanitative Ansatz zur Bestimmung der relativen Fluormengen am Ort der Infektion ausreichte, so ist doch im Allgemeinen wünschenswert probenbezogen die Sensitivität der Spule und damit die Güte der Spulenabstimmung zu bestimmen. Hierzu ist jedoch die Aufnahme von \(B_1\)-Karten unabdingbar und wird entsprechend im Kapitel 4 \(Bloch-Siegert B_1^+-Mapping\) näher addressiert. Der Schwerpunkt liegt hierbei, wie der Kapitelname bereits andeutet, auf der Bloch-Siegert Methode, die insbesondere in der präsentierten Implementierung in einer Turbo/ Multi Spin Echo Sequenz eine effiziente Nutzung der relativ langen \(T_\)2-Zeiten der Perfluorkarbone erlaubt. Da zudem die Bloch-Siegert-Methode eine rein phasenbasierte Methode ist, kann neben der aus den Daten erzeugten \(B_1\)-Karte zugleich ein unverfälschtes Magnitudenbild generiert werden, wodurch eine sehr effiziente Nutzung der vorhandenen Messzeit ermöglicht wird. Diese Eigenschaft ist insbesondere für \(^{19}F\) Bildgebung von besonderem Interesse, da hier für jede Messung, aufgrund der üblicherweise relativ geringen Konzentration an Fluoratomen, lange Messzeiten benötigt werden.
Zusammenfassend konnte anhand des untersuchten Tiermodells sowohl die Fähigkeit der MR Tomographie nachgewiesen werden Infektionen im Zeitverlauf darzustellen, als auch die Fähigkeit der MR Tomographie quantitative Informationen über den Verlauf der Infektion zu liefern. Desweiteren konnte eine Möglichkeit aufgezeigt werden, welche das Potential hat in vertretbarem Zeitrahmen auch in vivo B1+-Karten auf dem Fluorkanal zu erstellen und so einen zentralen Unsicherheitsfaktor, für Relaxometry und absolute Quantifizierung von \(^{19}F\) Daten in vivo, zu beseitigen.
Im Rahmen der vorliegenden Arbeit werden mit einem Rastertunnelmikroskop (RTM) Ladungsdichtemodulationen
(LDM) auf Oberflächen von drei verschiedenen Probensystemen
untersucht. Bei den Proben handelt es sich um Chrom auf Wolfram(110), Iridiumditellurid
(IrTe2) als Volumenmaterial und Eisen auf Rhodium(001). Es werden sowohl die Temperaturabhängigkeit
der Phasenübergänge als auch die Wechselwirkung zwischen magnetischen
und elektronischen Eigenschaften analysiert.
Chrom (Cr) ist ein einfaches Übergangsmetall, in dem sowohl eine klassische Ladungsdichtewelle
(LDW) als auch eine Spindichtewelle (SDW) auftreten. Die im Experiment
betrachteten Cr-Inseln auf Wolfram(110) schlagen eine Brücke zwischen dem Volumenmaterial
und ultradünnen Schichten. Dabei zeigt sich der Zusammenhang zwischen elektronischen
und magnetischen Eigenschaften in der Ausbildung einer LDW-Lücke und dem
gleichzeitigen Verschwinden des magnetischen Kontrastes bei lokalen Schichtdicken von
dCr = 4nm. Dies kann durch eine Rotation des Spindichtewellenvektors Q erklärt werden.
Für dCr < 3nm verschwindet die LDW erneut. Zusätzlich zur LDW und SDW
entsteht aufgrund der unterschiedlichen Gitterparameter von Chrom und Wolfram bei
lokalen Schichtdicken von dCr < 3nm eine Moiré-Überstruktur.
IrTe2 ist Gegenstand zahlreicher aktueller Forschungsaktivitäten und weist eine LDM mit
gleichzeitiger Transformation des atomaren Gitters auf. Ein Phasenübergang erster Ordnung
erzeugt zunächst bei der Übergangstemperatur TC = 275K eine Modulation mit
dem Wellenvektor q = 1/5(1, 1, 0). Mithilfe temperaturabhängiger RTM-Messungen kann
das Phasendiagramm um einen weiteren Übergang erster Ordnung bei TS = 180K erweitert
werden. Dabei bilden sich zunehmend Te-Dimere an der sichtbaren (001)-Oberfläche
und IrTe2 wechselt in einen Grundzustand mit maximaler Dichte von Dimeren und dem
Wellenvektor q = 1/6(1, 1, 0). Der Mechanismus beider Phasenübergänge wird durch die
Probenqualität und die Oberflächenpräparation beeinflusst, sodass die Phasenübergänge
erster Ordnung teilweise verlangsamt ablaufen. Durch eine Analyse der Oberflächendynamik
am Phasenübergang kann der zugrundeliegende Mechanismus des Domänenwachstums
im Realraum untersucht werden.
Im letzten Teil der Arbeit werden ultradünne Eisenfilme auf Rhodium(001) betrachtet.
Dabei treten auf der Doppellage Eisen (Fe) auf Rhodium (Rh) spannungsabhängige
elektronische Modulationen mit senkrecht zueinander orientierten Wellenvektoren
q1 = [(0, 30 ± 0, 03), 0, 0] und q2 = [0, (0, 30 ± 0, 03), 0] in Richtung [100] und [010] auf.
Temperaturabhängige Messungen zeigen die stetige Verkleinerung der Modulation beim
Erwärmen der Probe und somit einen Phasenübergang zweiter Ordnung. Die LDM tritt
auch auf der dritten und vierten Lage Eisen mit gleichgerichteten aber kleineren Wellenvektoren
q auf. Spinpolarisierte RTM-Daten zeigen einen c(2×2)-Antiferromagnetismus auf
einer Monolage Eisen. Für Fe-Bedeckungen von 1ML - 5ML tritt Ferromagnetismus
perpendikular zur Oberfläche auf. Diese Messungen zeigen erstmals gleichzeitiges Auftreten
einer elektronischen und magnetischen Phase in einem reinen 3d-Übergangsmetall
im Realraum.
Exploring the transport properties of the three-dimensional topological insulator material HgTe
(2015)
In the present thesis the transport properties of strained bulk HgTe devices are investigated. Strained HgTe forms a 3D TI and is of special interest for studying topological surface states, since it can be grown by MBE in high crystal quality. The low defect density leads to considerable mobility values, well above the mobilities of other TI materials. However, strained HgTe has a small band gap of ca. 20 meV. With respect to possible applications the question is important, under which conditions the surface transport occurs. To answer this question, the HgTe devices are investigated at dilution refrigerator temperatures (T<100 mK) in high magnetic fields of different orientation. The influence of top and back gate electrodes as well as surface protecting layers is discussed.
On the basis of an analysis of the quantum Hall behaviour it is shown that transport is dominated by the topological surface states in a surprisingly large parameter range. A dependence on the applied top gate voltage is presented for the topological surface states. It enables the first demonstration of an odd integer QHE sequence from the surfaces perpendicular to the magnetic field. Furthermore, the p-type QHE from the surface states is observed for the first time in any 3D TI. This is achieved in samples of high surface quality. It is concluded from the gate response that the screening behaviour in 3D TI devices is non-trivial. The transport data are qualitatively analysed by means of intuitive theoretical models.
Die zahnmedizinische Behandlung von Erkrankungen der Zähne oder im Bereich der Mundhöhle erfolgt bei Weitem nicht immer aus optischen Gründen. Diese Erkrankungen werden auch mit ernsthaften Erkrankungen in Zusammenhang gebracht. Studien haben gezeigt, dass einige Erkrankungen im Mund- und Zahnbereich zu Herz- und Lungenkrankheiten oder Diabetes führen können. Oftmals erstreckt sich die Pathologie oder Symptomatik von Mund- und Zahnerkrankungen über einen weiten Bereich. In der zahnmedizinischen Klinik kommen daher viele verschiedene diagnostische Apparate zum Einsatz. Allerdings zählt die Magnetresonanztomographie, die sich in anderen Bereichen bereits zum wichtigsten bildgebenden Diagnosetool entwickelt hat, dort noch nicht zu den Standardverfahren. Dabei liegen ihre Vorteile auf der Hand: sie ist bekannt für sehr gute Bildkontraste vor allem zwischen verschiedenen Weichgewebsarten und kommt ohne gefährliche ionisierende Strahlung aus. Wahrscheinlich ist ersteres der Grund, warum die MRT in der Zahnmedizin noch nicht sonderlich vertreten ist, kommt es dort oft auf die kontrastreiche Darstellung von Hartgeweben an. Neueste Entwicklungen und Studien belegen jedoch die vielseitigen Vorteile der MRT auch in diesem Bereich. Ziel dieser Arbeit von der applikativen Seite betrachtet, war es, das enorme Potential der MRT in den vielseitigen Bereichen der Zahnmedizin weiterhin aufzuzeigen. Viele dieser Anwendungen stellen jedoch sehr hohe Anforderungen an die Systeme. Meist sind die darzustellenden Strukturen sehr klein und erfordern eine hohe Auflösung. Während man beim Röntgenverfahren beispielsweise die Energie des Strahles (Dosis) steigern kann, bedeutet dies in der MRT (ohne das Gerät zu wechseln) eine Verlängerung der Messzeit. Gerade im Bereich des Kopfes kommt es oft zu ungewollten Bewegungen, die das Ergebnis und die Reproduzierbarkeit der gewonnenen diagnostischen Informationen verschlechtern oder gänzlich unbrauchbar machen. Die grösste Herausforderung dabei ist die dreidimensionale Abformung von Zahnoberflächen in der Prothetik. Dieses Verfahren kann eine aufwändige und unangenehme manuelle Abformung der Zähne und die Herstellung eines Zwischengipsmodells ersetzen und ein direktes dreidimensionales Modell der Zahnoberflächen produzieren. Durch die moderne CAD-/CAM-Technik kann daraus vom Zahntechniker direkt eine Zahnrestauration erstellt werden. Daher war ein wichtiger Bestandteil des Projekts dentale MRT die Entwicklung einer Methode zur Erkennung und gleichzeitiger Korrektur von Bewegungen.
Verschiedenste Anforderungen waren an die Methode gestellt. Zum einen muss die Methode bereits Bewegungen im Bereich von ~100 µm erkennen, um die Anforderungen an die finale Bildauflösung zu unterschreiten. Bei der dentalen Abformung wird eine 1-Kanal-Empfängerspule verwendet und je nach Messung kann der Patient dabei auf dem Bauch oder Rücken liegen. Weiterhin muss die Bewegungserkennung ohne zusätzliche externe Geräte wie Kameras, deren Sicht z.B. durch den Patienten verdeckt ist, durchführbar sein.
Die vorliegende Arbeit deckt also zwei größere Themenblöcke ab. Zum einen wurden in der Arbeit neue Applikationen entwickelt oder weiterentwickelt, um verschiedenen Bereichen der Zahnmedizin den Zugang zu MRTUntersuchungen zu eröffnen. Kapitel 4 beschreibt die Möglichkeit, die Bewegung des Kiefergelenks dynamisch zu erfassen. Es stellte sich in der Arbeit heraus, dass sowohl die Bewegung von Weichgewebeanteilen darstellbar waren, als auch der intraartikuläre Abstand im Kiefergelenk unter Kaubelastung in Echtzeit vermessen werden konnte. Dabei wurde die Bildgebungssequenz und der zugehörige Rekonstruktionsalgorithmus so entwickelt, dass die Daten flexibel und ohne Vorwissen akquiriert und aufbereitet werden können. Hierbei konnten verschiedenen Pathologien anhand der dynamischen Bilder sichtbar gemacht werden und die dynamische MRT konnte Erkrankungen erkennen, die mit anderen Mitteln nicht sichtbar waren. Die vielen diagnostischen Möglichkeiten, die dadurch entstehen sind bisher noch nicht untersucht und sollten durch großangelegte Studien untersucht und belegt werden.
Kapitel 5 beschreibt die Ergebnisse einer großangelegten Studie im Bereich der dentomaxillären Bildgebung . Die diagnostischen Möglichkeiten der MRT für die kieferorthopädische Anwendung liegen klar auf der Hand. Die typischen Patienten in der Kieferorthopädie sind Kinder und Jugendliche. Die Abwesenheit von gewebsschädigender Strahlung ist hier ein besonderer Vorteil der MRT. Eine Messung dauert zudem nach diversen Weiterentwicklungen der Methode nur noch 2 (bzw. 4) Minuten. Die Auflösung in den gerenderten Bildern beträgt 0.25x0.25x0.5 mm. Mit der Methode konnte unter anderem die Geminisierung einer Zahnwurzel und der Abstand des Zahnmarks zur Zahnoberfläche (Zahnschmelz) dargestellt und vermessen werden.
Kapitel 6 stellt Neuentwicklungen im Bereich der dentalen Abformung von Zahnoberflächen dar. Hier wurde eine neue Methode entwickelt um den Patientenkomfort bei der Messung zu steigern und so Bewegungen im Vorhinein zu unterbinden. Bei der alten Methode liegt der Patient auf dem Bauch und ein großer Teil der Mundhöhle ist mit Kontrastmittel befüllt. Durch die Verwendung einer präparierten Tiefziehschiene kann das Kontrastmittel nun lokal appliziert
werden und eine Messung in Rückenlage das Patienten ist somit problemlos möglich. Die damit verbundene Reproduzierbarkeit der Abformungsergebnisse wäre durch eine großangelegte Studie zu zeigen. Die Hauptaufgabe der vorliegenden Dissertation war es, eine Methode zur Bewegungskorrektur zu entwickeln, die es ohne eine große Anzahl an Zusatzgeräten ermöglicht, die Bewegung eines Subjekts während der Messung zu erfassen und dementsprechend zu korrigieren. Diese neue Methode, gestützt auf einer Messung eines MRT-aktiven Markers der am Subjekt angebracht wird, beruht außer der Verwendung des Markers nur auf MRT-Hardware. Die Methode wird in Kapitel 8 vorgestellt. Da es sich bei der Methode um eine Neuentwicklung handelt, war es in erster Linie wichtig, die Einflüsse der verschiedenen Parameter, die sich auf die Positionierungsgenauigkeit auswirken, abzuschätzen und letzten Endes festzulegen. Dies wurde in mehreren Vorstudien, Experimenten und Computersimulationen abgehandelt. In der Arbeit konnte durch Validierungsexperimente gezeigt werden dass sich mit dem bildbasierten Navigator Bewegungen im Genauigkeitsbereich von ~50 µm (Translation) und ~0.13◦(Rotation) detektieren lassen. Mit den Positionsinformationen lassen sich MRT-Daten retrospektiv korrigieren oder idealerweise das Bildgebungsvolumen in Echtzeit anpassen um Inkonsistenzen in den Daten im Vorhinein vorzubeugen. Durch Bewegung beeinträchtigte in-vivo Daten konnten so mit der Methode korrigiert werden und anhand eines geeigneten Phantoms konnte die Verbesserung der Erkennung von Kanten, wie sie beispielsweise bei der dentalen Abformung angewandt wird, gezeigt werden. Die kontinuierlichen Entwicklungen in den Bereichen Hard-, Software und Algorithmik ermöglichen weitere hochauflösende Anwendungen. In Kapitel 9 sind die Ergebnisse einer Studie gezeigt, die sich mit der Analyse der Handbewegungen während einer Messung beschäftigt. Für eine hochauflösenden Darstellung der Handanatomie bei 7 T ist eine Unterbindung der Handbewegung sehr wichtig. Um ein geeignetes Design für eine Empfängerspule zu entwerfen, die Bewegungen der Hand unterbindet, wurde eine qualitative Bewegungsanalyse der Hand in mehreren verschiedenen Positionen durchgeführt. Durch Vergleich der Ergebnisse konnte so auf geeignete Designs zurückgeschlossen werden.
In oxidischen Heterostrukturen rufen Neuordnung von Ladung und Spin eine Vielzahl von unerwarteten physikalischen Eigenschaften hervor. Die Möglichkeit, Leitfähigkeit, Magnetismus oder auch Hochtemperatur-Supraleitung zu kontrollieren, machen diese künstlich hergestellten Materialien vor allem in Hinblick auf eine zukünftige Anwendung in der Mikroelektronik äußerst interessant. Dies erfordert jedoch ein grundsätzliches Verständnis für die zugrunde liegenden Mechanismen. Die vorliegende Doktorarbeit befasst sich mit photonengestützter Spektroskopie, die einen direkten Zugang zur elektronischen Struktur dieser Heterostruktursysteme ermöglicht. Ein weiteres Ziel ist es, geeignete spektroskopische Methoden zur Charakterisierung der vergrabenen Schichten zu etablieren.
Zwei prototypische oxidische Mehrschichtsysteme stehen im Zentrum der hier vorgestellten Untersuchungen. Das LaAlO3/SrTiO3-Heterostruktursystem weist ab einer kritischen LaAlO3-Filmdicke an der Grenzfläche ein zweidimensionales Elektronensystem mit hochmobilen Ladungsträgern auf. Als treibender Mechanismus wird die elektronische Rekonstruktion diskutiert. Im Rahmen dieser Arbeit wurde dieses zweidimensionale Elektronensystem mithilfe der Photoelektronenspektroskopie und der resonanten inelastischen Röntgenstreuung charakterisiert. Die daraus bestimmten Ladungsträgerdichten weisen im Vergleich mit Daten aus Transportmessungen auf eine Koexistenz von lokalisierten und mobilen Ladungsträgern an der Grenzfläche hin. Die Analyse von Rumpfniveau- und Valenzbandspektren zeigt, dass man zur Erklärung der experimentellen Resultate ein modifiziertes Bild der elektronischen Rekonstruktion benötigt, bei der Sauerstofffehlstellen an der LaAlO3-Oberfläche als Ladungsreservoir dienen könnten. Mithilfe der resonanten Photoelektronenspektroskopie war es möglich, die metallischen Zustände am chemischen Potential impulsaufgelöst zu spektroskopieren. So gelang es erstmals, die vergrabene Fermi-Fläche einer oxidischen Heterostruktur zu vermessen. Außerdem konnten Titan-artige Zustände identifiziert werden, die höchstwahrscheinlich durch Sauerstofffehlstellen im SrTiO3 lokalisiert sind. Diese werden als mögliche Quelle für den Ferromagnetismus interpretiert, der mit der supraleitenden Phase in der LaAlO3/SrTiO3-Heterostruktur koexistiert.
Bei dem anderen hier untersuchten Mehrschichtsystem handelt es sich um die LaNiO3-LaAlO3-Übergitterstruktur. Der Einbau des metallischen LaNiO3 in eine Heterostruktur ist aufgrund seiner Nähe zu einer korrelationsinduzierten isolierenden Phase hinsichtlich einer kontrollierten Ausbildung von neuartigen Phasen besonders interessant. In der Tat beobachtet man unterhalb einer LaNiO3-Schichtdicke von vier Einheitszellen einen kontinuierlichen Metall-Isolator-Übergang, der sich in den Valenzbandspektren durch einen Verlust an Quasiteilchenkohärenz äußert. Auch wenn die impulsaufgelösten
Daten am Fermi-Niveau durch Photoelektronenbeugung beeinflusst sind, so lässt sich dennoch eine Fermi-Fläche identifizieren. Ihre Topologie bietet die Möglichkeit eines Fermi-Flächen-Nestings mit der Ausbildung einer Spindichtewelle. Die Resultate unterstützen die Hinweise auf eine magnetische Ordnung im zweidimensionalen Grundzustand.
In this thesis, thin-film solar cells on the basis of Cu(In,Ga)(S,Se)2 (CIGSSe) were investigated.
Until today, most high efficient CIGSSe-based solar cells use a toxic and wetchemical deposited CdS buffer layer, which doesn’t allow a dry inline production. However, a promising and well-performing alternative buffer layer, namely indium sulfide, has been found which doesn’t comprise these disadvantages. In order to shed light on these well-performing devices, the surfaces and in particular the interfaces which play a major role for the charge carrier transport are investigated in the framework of this thesis. Both, the chemical and electronic properties of the solar cells’ interfaces were characterized.
In case of the physical vapor deposition of an InxSy-based buffer layer, the cleaning step of the CdS chemical-bath deposition is not present and thus changes of the absorber surface have to be taken into account. Therefore, adsorbate formation, oxidation, and segregation of absorber elements in dependence of the storing temperature and the humidity are investigated in the first part of this thesis.
The efficiencies of CIGSSe-based solar cells with an InxSy buffer layer depend on the nominal indium concentration x and display a maximum for x = 42 %. In this thesis, InxSy samples with a nominal indium concentration of 40.2% ≤ x ≤ 43.2% were investigated by surface-sensitive and surface-near bulk-sensitive techniques, namely with photoemission spectroscopy (PES) and x-ray emission spectroscopy (XES). The surfaces of the films were found to be sulfur-poor and indium-rich in comparison with stoichiometric In2S3. Moreover, a direct determination of the band alignment at the InxSy/CISSe interface in dependence of the nominal indium concentration x was conducted with the help of PES and inverse PES (IPES) and a flat band alignment was found for x = 42 %.
In order to study the impact of a heat treatment as it occurs during subsequent cell process steps, the indium sulfide-buffered absorbers were annealed for 30 minutes under UHV conditions at 200 °C after the initial data set was taken. Besides a reported enhanced solar cell performance, a significant copper diffusion from the absorber into the buffer layer takes place due to the thermal treatment. Accordingly, the impact of the copper diffusion on the hidden InxSy/CISSe interface was discussed and for x = 40.2% a significant cliff (downwards step in the conduction band) is observed. For increasing x, the alignment in the conduction band turns into a small upwards step (spike) for the region 41% ≤ x ≤ 43.2%. This explains the optimal solar cell performance for this indium contents.
In a further step, the sodium-doped indium sulfide buffer which leads to significantly higher efficient solar cells was investigated. It was demonstrated by PES/IPES that the enhanced performance can be ascribed to a significant larger surface band gap in comparison with undoped InxSy. The occurring spike in the Na:InxSy/CISSe band alignment gets reduced due to a Se diffusion induced by the thermal treatment. Furthermore, after the thermal treatment the sodium doped indium sulfide layer experiences a copper diffusion which is reduced by more than a factor of two compared to pure InxSy.
Next, the interface between the Na:InxSy buffer layer and the i-ZnO (i = intrinsic, non-deliberately doped), as a part of the transparent front contact was analyzed. The i-ZnO/Na:InxSy interface shows significant interdiffusion, leading to the formation of, e.g., ZnS and hence to a reduction of the nominal cliff in the conduction band alignment.
In the last part of this thesis, the well-established surface-sensitive reflective electron energy loss spectroscopy (REELS) was utilized to study the CIGSSe absorber, the InxSy buffer, and annealed InxSy buffer surfaces. By fitting the characteristic inelastic scattering cross sections λK(E) with Drude-Lindhard oscillators the dielectric function was identified. The determined dielectric functions are in good agreement with values from bulk-sensitive optical measurements on indium sulfide layers. In contrast, for the chalcopyrite-based absorber significant differences appear. In particular, a substantial larger surface band gap of the CIGSSe surface of E^Ex_Gap = (1.4±0.2) eV in comparison with bulk values is determined. This provides for the first time an independent verification of earlier PES/IPES results. Finally, the electrons’ inelastic mean free paths l for the three investigated surfaces are compared for different primary energies with theoretical values and the universal curve.
Das Ziel dieser Arbeit ist neben der Synthese von Sol-Gel-Funktionsschichten auf der Basis von
transparent leitfähigen Oxiden (transparent conducting oxides, TCOs) die umfassende infrarotoptische und elektrische Charakterisierung sowie Modellierung dieser Schichten. Es wurden sowohl über klassische Sol-Gel-Prozesse als auch über redispergierte Nanopartikel-Sole spektralselektive Funktionsschichten auf Glas- und Polycarbonat-Substraten appliziert, die einen möglichst hohen Reflexionsgrad im infraroten Spektralbereich und damit einhergehend einen möglichst geringen Gesamtemissionsgrad sowie einen niedrigen elektrischen Flächenwiderstand aufweisen. Zu diesem Zweck wurden dotierte Metalloxide, nämlich einerseits Zinn-dotiertes Indiumoxid (tin doped indium oxide, ITO) und andererseits Aluminium-dotiertes Zinkoxid (aluminum doped zinc oxide, AZO)verwendet. Im Rahmen dieser Arbeit wurden vertieft verschiedene Parameter untersucht, die bei der Präparation von niedrigemittierenden ITO- und AZO-Funktionsschichten im Hinblick auf die Optimierung ihrer infrarot-optischen und elektrischen Eigenschaften sowie ihrer Transmission im sichtbaren Spektralbereich von Bedeutung sind.
Neben der Sol-Zusammensetzung von klassischen Sol-Gel-ITO-Beschichtungslösungen wurden auch
die Beschichtungs- und Ausheizparameter bei der Herstellung von klassischen Sol-Gel-ITO- sowie
-AZO-Funktionsschichten charakterisiert und optimiert. Bei den klassischen Sol-Gel- ITO-Funktionsschichten konnte als ein wesentliches Ergebnis der Arbeit der Gesamtemissionsgrad um 0.18 auf 0.17, bei in etwa gleichbleibenden visuellen Transmissionsgraden und elektrischen Flächenwiderständen, reduziert werden, wenn anstelle von (optimierten) Mehrfach-Beschichtungen Einfach-Beschichtungen mit einer schnelleren Ziehgeschwindigkeit anhand des Dip-Coating-Verfahrens hergestellt wurden. Mit einer klassischen Sol-Gel-ITO-Einfach-Beschichtung, die mit einer deutlich erhöhten Ziehgeschwindigkeit von 600 mm/min gedippt wurde, konnte mit einem Wert von 0.17 der kleinste Gesamtemissionsgrad dieser Arbeit erzielt werden.
Die Gesamtemissionsgrade und elektrischen Flächenwiderstände von klassischen Sol-Gel-AZOFunktionsschichten konnten mit dem in dieser Arbeit optimierten Endheizprozess deutlich gesenkt werden. Bei Neunfach-AZO-Beschichtungen konnten der Gesamtemissionsgrad um 0.34 auf 0.50 und der elektrische Flächenwiderstand um knapp 89 % auf 65 Ω/sq verringert werden. Anhand von Hall-Messungen konnte darüber hinaus nachgewiesen werden, dass mit dem optimierten Endheizprozess, der eine erhöhte Temperatur während der Reduzierung der Schichten aufweist, mit N = 4.3·1019 cm-3 eine etwa doppelt so hohe Ladungsträgerdichte und mit µ = 18.7 cm2/Vs eine etwa drei Mal so große Beweglichkeit in den Schichten generiert wurden, im Vergleich zu jenen Schichten, die nach dem alten Endheizprozess ausgehärtet wurden. Das deutet darauf hin, dass bei dem optimierten Heizschema sowohl mehr Sauerstofffehlstellen und damit eine höhere Ladungsträgerdichte als auch Funktionsschichten mit einem höheren Kristallisationsgrad und damit einhergehend einer höheren Beweglichkeit ausgebildet werden.
Ein Großteil der vorliegenden Arbeit behandelt die Optimierung und Charakterisierung von ITO-Nanopartikel-Solen bzw. -Funktionsschichten. Neben den verwendeten Nanopartikeln, dem
Dispergierungsprozess, der Beschichtungsart sowie der jeweiligen Beschichtungsparameter und der
Nachbehandlung der Funktionsschichten, wurde erstmals in einer ausführlichen Parameterstudie die
Sol-Zusammensetzung im Hinblick auf die Optimierung der infrarot-optischen und elektrischen
Eigenschaften der applizierten Funktionsschichten untersucht. Dabei wurde insbesondere der Einfluss der verwendeten Stabilisatoren sowie der verwendeten Lösungsmittel auf die Schichteigenschaften charakterisiert. Im Rahmen dieser Arbeit wird dargelegt, dass die exakte Zusammensetzung der Nanopartikel-Sole einen große Rolle spielt und die Wahl des verwendeten Lösungsmittels im Sol einen größeren Einfluss auf den Gesamtemissionsgrad und die elektrischen Flächenwiderstände der applizierten Schichten hat als die Wahl des verwendeten Stabilisators. Allerdings wird auch gezeigt, dass keine pauschalen Aussagen darüber getroffen werden können, welcher Stabilisator oder welches Lösungsmittel in den Nanopartikel-Solen zu Funktionsschichten mit kleinen Gesamtemissionsgraden und elektrischen Flächenwiderständen führt. Stattdessen muss jede einzelne Kombination von verwendetem Stabilisator und Lösungsmittel empirisch getestet werden, da jede Kombination zu Funktionsschichten mit anderen Eigenschaften führt.
Zudem konnte im Rahmen dieser Arbeit erstmals stabile AZO-Nanopartikel-Sole über verschiedene Rezepte hergestellt werden.
Neben der Optimierung und Charakterisierung von ITO- und AZO- klassischen Sol-Gel- sowie Nanopartikel-Solen und -Funktionsschichten wurden auch die infrarot-optischen Eigenschaften dieser Schichten modelliert, um die optischen Konstanten sowie die Schichtdicken zu bestimmen. Darüber hinaus wurden auch kommerziell erhältliche, gesputterte ITO- und AZO-Funktionsschichten modelliert. Die Reflexionsgrade dieser drei Funktionsschicht-Typen wurden einerseits ausschließlich mit dem Drude-Modell anhand eines selbstgeschriebenen Programmes in Sage modelliert, und andererseits mit einem komplexeren Fit-Modell, welches in der kommerziellen Software SCOUT aus dem erweiterten Drude-Modell, einem Kim-Oszillator sowie dem OJL-Modell aufgebaut wurde. In diesem Fit-Modell werden auch die Einflüsse der Glas-Substrate auf die Reflexionsgrade der applizierten Funktionsschichten berücksichtigt und es können die optischen Konstanten sowie die Dicken der Schichten ermittelt werden. Darüber hinaus wurde im Rahmen dieser Arbeit ein Ellipsometer installiert und geeignete Fit-Modelle entwickelt, anhand derer die Ellipsometer-Messungen ausgewertet und die optischen Konstanten sowie Schichtdicken der präparierten Schichten bestimmt werden können.
In this thesis, I present a model system for carbohydrate interactions with single-crystalline Ru surfaces. Geometric and electronic properties of copper phthalocyanine (CuPc) on top of graphene on hexagonal Ru(0001), rectangular Ru(10-10) and vicinal Ru(1,1,-2,10) surfaces have been studied. First, the Fermi surfaces and band structures of the three Ru surfaces were investigated by high-resolution angle-resolved photoemission spectroscopy. The experimental data and theoretical calculations allow to derive detailed information about the momentum-resolved electronic structure. The results can be used as a reference to understand the chemical and catalytic properties of Ru surfaces. Second, graphene layers were prepared on the three different Ru surfaces. Using low-energy electron diffraction and scanning tunneling microscopy, it was found that graphene can be grown in well-ordered structures on all three surfaces, hexagonal Ru(0001), rectangular Ru(10-10) and vicinal Ru(1,1,-2,10), although they have different surface symmetries. Evidence for a strong interaction between graphene and Ru surfaces is a 1.3-1.7e V increase in the graphene pi-bands binding energy with respect to free-standing graphene sheets. This energy variation is due to the hybridization between the graphene pi bands and the Ru 4d electrons, while the lattice mismatch does not play an important role in the bonding between graphene and Ru surfaces. Finally, the geometric and electronic structures of CuPc on Ru(10-10), graphene/Ru(10-10), and graphene/Ru(0001) have been studied in detail. CuPc molecules can be grown well-ordered on Ru(10-10) but not on Ru(0001). The growth of CuPc on graphene/Ru(10-10) and Ru(0001) is dominated by the Moire pattern of graphene. CuPc molecules form well-ordered structures with rectangular unit cells on graphene/Ru(10-10) and Ru(0001). The distance of adjacent CuPc molecules is 1.5 and 1.3 nm on graphene/Ru(0001) and 1.54 and 1.37 nm on graphene/Ru(10-10). This indicates that the molecule-substrate interaction dominates over the intermolecular interaction for CuPc molecules on graphene/Ru(10-10) and graphene/Ru(0001).
The results of two analyses searching for supersymmetry (SUSY) in data of the ATLAS experiment are presented in this thesis. The data were recorded in proton-proton collisions at the Large Hadron Collider in 2012 at a centre of mass energy of \(\sqrt{s}\)=8 TeV and correspond to an integrated luminosity of 20.3 fb\(^{−1}\). The first search is performed in signatures containing an opposite-sign electron or muon pair, which is compatible with originating from a Z boson decay, in addition to jets and large missing transverse momentum. The analysis targets the production of squarks and gluinos in R-parity conserving (RPC) models with SUSY breaking via General Gauge Mediation (GGM). The main Standard Model (SM) backgrounds are \(t\overline t\), WW, W+t and Z to \(\tau \tau\) processes which are entirely estimated from data using different-flavour events. Besides that, the SM production of Z bosons in association with jets and large fake missing momentum from mismeasurements plays a role and is predicted with the data-driven jet smearing method. Backgrounds from events with fake leptons are estimated with the data-driven matrix method. WZ/ZZ production as well as smaller background contributions are determined from Monte-Carlo simulations. The search observes an excess of data over the SM prediction with a local significance of 3.0 \(\sigma\) in the electron channel, 1.7 \(\sigma\) in the muon channel and 3.0 \(\sigma\) when the two channels are added together. The results are used to constrain the parameters of the GGM model. The second analysis uses the already published results of an ATLAS search for SUSY in events with one isolated electron or muon, jets and missing transverse momentum to reinterpret them in the context of squark and gluino production in SUSY models with R-parity violating (RPV) \(LQ\overline D\)-operators. In contrast to RPC models, the lightest SUSY particle (LSP) is not stable but decays into SM particles. "Standard" analyses often do not consider SUSY models with RPV although they are in principle sensitive to them. The exclusion limits on the squark and gluino mass obtained from the reinterpretation extend up to 1200 GeV. These are the first results by any ATLAS SUSY search which systematically cover a wide range of RPV couplings in the case of prompt LSP decays. However, the analysis is not sensitive to the full parameter space of the \(LQ\overline D\)-model and reveals gaps in the ATLAS SUSY program which have to be closed by dedicated search strategies in the future.
3d-Übergangsmetallphthalocyanin-Moleküle auf Metalloberflächen: Der Einfluss der d-Orbitalbesetzung
(2015)
Im Rahmen dieser Dissertation wird die Untersuchung von 3d-Übergangsmetallphthalocyanin- Molekülen (ÜMPc) – quadratisch-planaren organischen Molekülen, welche im Zentrum ein 3d-Übergangsmetallion besitzen – auf metallischen Oberflächen vorgestellt. Der Fokus dieser Arbeit liegt dabei auf dem Einfluss der d-Orbitalbesetzung auf die magnetischen, elektronischen und strukturellen Eigenschaften der adsorbierten Moleküle, die mit Hilfe der Rastertunnelmikroskopie und -spektroskopie charakterisiert wurden. Die gewonnen Ergebnisse werden zum Teil mit theoretischen Berechnungen analysiert und interpretiert.
Die erste Hälfte der experimentellen Auswertung behandelt die Untersuchung dieser Moleküle auf Ag(001) in Hinblick auf die Existenz einer magnetischen Wechselwirkung, bei der ein unkompensiertes magnetisches Moment des Moleküls durch die Substratelektronen abgeschirmt wird. Dieser Effekt wird als Kondo-Abschirmung bezeichnet und erzeugt in der Zustandsdichte des Moleküls eine Resonanz am Fermi-Niveau. Die Messungen zeigen, dass diese Resonanz ausschließlich am Zentralion von MnPc vorgefunden wird, wohingegen sie bei allen anderen 3d-Übergangsmetallphthalocyanin-Molekülen, die eine höhere d-Orbitalbesetzung besitzen, nicht vorhanden ist. Anhand theoretischer Berechnungen kann die Ursache für dieses Verhalten darauf zurückgeführt werden, dass von allen d-Orbitalen einzig das dz2-Orbital mit dem Substrat geeignet hybridisiert, um eine Kondo-Abschirmung zu erzeugen. Da ausschließlich MnPc einen unkompensierten Spin in diesem Orbital besitzt, kann die An- bzw. Abwesenheit
des Kondo-Effekts auf die unterschiedliche Besetzung des dz2-Orbitals zurückgeführt werden. Neben der eben erwähnten Kondo-Resonanz ist bei MnPc ein weiteres Merkmal am Fermi- Niveau überlagert. Durch die Analyse der räumlichen Verteilung, den Vergleich mit anderen Molekülen und der Manipulation des MnPc-Moleküls kann gezeigt werden, dass es sich bei diesem Merkmal um einen d-Orbitalzustand handelt. Die Manipulation des Moleküls durch gezieltes Entfernen von Wasserstoffatomen ermöglicht darüber hinaus die Stärke der Kondo-Abschirmung zu beeinflussen.
In der zweiten Hälfte der experimentellen Auswertung werden Moleküle auf bismutinduzierten Oberflächenlegierungen der Edelmetalle Cu(111) und Ag(111) untersucht. Diese Legierungen zeichnen sich durch einen ausgeprägten Rashba-Effekt aus, der durch eine Aufspaltung der Parabeldispersion und Aufhebung der Spin-Entartung im zweidimensionalen Elektronengas der Oberflächenlegierung charakterisiert ist. Das Wachstumsverhalten von CuPc und MnPc auf diesen Oberflächen zeigt ein sehr gegensätzliches Verhalten. Während bei MnPc die Substrat-Molekül-Wechselwirkung dominant ist, wodurch diese Moleküle immer einen festen Adsorptionsplatz auf der Oberfläche besitzen, ist diese Wechselwirkung bei CuPc schwach ausgeprägt. Aus diesem Grund wandern die CuPc-Moleküle zu den Stufenkanten und bilden Cluster. Das unterschiedliche Wachstumsverhalten der Moleküle lässt sich auf die partiell-gefüllten d-Orbitale von MnPc zurückführen, die aus der Molekülebene ragen, mit dem Substrat hybridisieren und damit das Molekül an das Substrat binden. Bei CuPc hingegen sind diese d-Orbitale gefüllt und die Hybridisierung kann nicht stattfinden.
Im letzten Abschnitt werden die elektronischen und magnetischen Eigenschaften von MnPc auf diesen Substraten behandelt, die einige Besonderheiten aufweisen. So bildet sich durch die Adsorption des Moleküls auf den Oberflächen eine Grenzschichtresonanz aus, die eine partielle Füllung erkennen lässt. Spektroskopiedaten, aufgenommen am Ort der Grenzschichtresonanz, weisen eine symmetrisch um das Fermi-Niveau aufgespaltene Resonanz auf. Die Intensität der unter- und oberhalb der Fermi-Energie befindlichen Resonanz zeigen dabei ein komplementäres Verhalten bzgl. der jeweiligen Lage auf der Grenzschichtresonanz: An den Orten, an denen die Resonanz unterhalb des Fermi-Niveaus ihre maximale Intensität besitzt, ist die Resonanz oberhalb des Fermi-Niveaus nicht vorhanden und umgekehrt. Diese experimentellen Beobachtungen werden mit einem Modellansatz erklärt, welcher die Wirkung eines effektiven Magnetfeldes und eine Spin-Filterung postuliert.
The combination of a topological insulator (TI) and a superconductor (S), which together
form a TI/S interface, is expected to influence the possible surface states in the
TI. It is of special interest, if the theoretical prediction of zero energy Majorana states
in this system is verifiable. This thesis presents the experimental realization of such
an interface between the TI strained bulk HgTe and the S Nb and studies if the afore
mentioned expectations are met.
As these types of interfaces were produced for the first time the initial step was
to develop a new lithographic process. Optimization of the S deposition technique as
well as the application of cleaning processes allowed for reproducible fabrication of
structures. In parallel the measurement setup was upgraded to be able to execute the
sensitive measurements at low energy. Furthermore several filters have been implemented
into the system to reduce high frequency noise and the magnetic field control
unit was additionally replaced to achieve the needed resolution in the μT range.
Two kinds of basic geometries have been studied: Josephson junctions (JJs) and
superconducting quantum interference devices (SQUIDs). A JJ consists of two Nb contacts
with a small separation on a HgTe layer. These S/TI/S junctions are one of the
most basic structures possible and are studied via transport measurements. The transport
through this geometry is strongly influenced by the behavior at the two S/TI
interfaces. In voltage dependent differential resistance measurements it was possible
to detect multiple Andreev reflections in the JJ, indicating that electrons and holes are
able to traverse the HgTe gap between both interfaces multiple times while keeping
phase coherence. Additionally using BTK theory it was possible to extract the interface
transparency of several junctions. This allowed iterative optimization for the highest
transparency via lithographic improvements at these interfaces. The increased transparency
and thus the increased coupling of the Nb’s superconductivity to the HgTe
results in a deeper penetration of the induced superconductivity into the HgTe. Due
to this strong coupling it was possible to enter the regime, where a supercurrent is
carried through the complete HgTe layer. For the first time the passing of an induced
supercurrent through strained bulk HgTe was achieved and thus opened the area for
detailed studies. The magnetic dependence of the supercurrent in the JJ was recorded,
which is also known as a Fraunhofer pattern. The periodicity of this pattern in magnetic
field compared to the JJ geometry allowed to conclude how the junction depends
on the phase difference between both superconducting contacts. Theoretical calculations
predicted a phase periodicity of 4p instead of 2p, if a TI is used as weak link
material between the contacts, due to the presence of Majorana modes. It could clearly
be shown that despite the usage of a TI the phase still was 2p periodic. By varying
further influencing factors, like number of modes and phase coherence length in the
junction, it might still be possible to reach the 4p regime with bound Majorana states
in the future. A good candidate for further experiments was found in capped HgTe
samples, but here the fabrication process still has to be developed to the same quality
as for the uncapped HgTe samples.
The second type of geometry studied in this thesis was a DC-SQUID, which consists
of two parallel JJs and can also be described as an interference device between two JJs.
The DC-SQUID devices were produced in two configurations: The symmetric SQUID,
where both JJs were identical, and the asymmetric SQUID, where one JJ was not linear,
but instead has a 90° bent. These configurations allow to test, if the predicted
uniformity of the superconducting band gap for induced superconductivity in a TI
is valid. While the phase of the symmetric SQUID is not influenced by the shape of
the band gap, the asymmetric SQUID would be in phase with the symmetric SQUID
in case of an uniform band gap and out of phase if p- or d-wave superconductivity
is dominating the transport, due to the 90° junction. As both devices are measured
one after another, the problem of drift in the coil used to create the magnetic field has
to be overcome in order to decide if the oscillations of both types of SQUIDs are in
phase. With an oscillation period of 0.5 mT and a drift rate in the range of 5.5 μT/h
the measurements on both configurations have to be conducted in a few hours. Only
then the total shift is small enough to compare them with each other. For this to be
possible a novel measurement system based on a real time micro controller was programmed,
which allows a much faster extraction of the critical current of a device. The
measurement times were reduced from days to hours, circumventing the drift problems
and enabling the wanted comparison. After the final system optimizations it has
been shown that the comparison should now be possible. Initial measurements with
the old system hinted that both types of SQUIDs are in phase and thus the expected
uniform band gap is more likely. With all needed optimizations in place it is now up
to the successors of this project to conclusively prove this last point.
This thesis has proven that it is possible to induce superconductivity in strained
bulk HgTe. It has thus realized the most basic sample geometry proposed by Fu and
Kane in 2008 for the appearance of Majorana bound states. Based on this work it is
now possible to further explore induced superconductivity in strained bulk HgTe to
finally reach a regime, where the Majorana states are both stable and detectable.
Magnetometrie mit Diamant
(2015)
Gegenstand der Arbeit ist die Magnetometrie mit Stickstoff-Fehlstellen-Zentren im Diamantgitter und die Entwicklung eines Rastersondenmagnetometers auf Basis eines Ensembles dieser Defektzentren. Ein solches Instrument verspricht eine bislang nicht erreichte Kombination von Feldsensitivität und räumlicher Auflösung während einer Magnetfeldmessung, und kann damit einen wichtigen Beitrag für das Verständnis von magnetischen Systemen und Phänomenen liefern.
Die Arbeit widmet sich zunächst dem Verständnis der elektronischen Zustände des Defekts, und wie diese optisch untersucht werden können. Gleichzeitige Anregung der Zentren durch sichtbares Licht und elektromagnetischer Strahlung im Bereich von Mikrowellenfrequenzen machen es möglich, die elektronische Spinstruktur des Defekts zu messen und zu manipulieren. Dadurch kann direkt der Einfluss von externen Magnetfeldern auf die Energie der Spinzustände ausgelesen werden. Die quantenmechanischen Auswahlregeln der verschiedenen Anregungen können für eine selektive Anregung der Zentren entlang einer bestimmten kristallographischen Achse verwendet werden. Damit kann eine Ensemble von Defekten zur Vektormagnetometrie, ohne auf ein zusätzliches äußeres Magnetfeld angewiesen zu sein, welches die untersuchte Probe nachhaltig beeinflussen kann.
Anschließend wird die Entwicklung einer geeigneten Mikrowellenantenne dargestellt, die in einem späteren Rastersondenexperiment mit den Defekten auf geringem Raum eingesetzt werden kann. Außerdem werden die einzelnen Schritte präsentiert, wie die Farbzentren im Diamantgitter erzeugt werden und aus großen Diamantplättchen Nanostrukturen erzeugt werden, die als Rasterkraftsonden eingesetzt werden können.
Die fertigen Sonden können in einem modularen Rasterkraftaufbau verwendet werden, der über einen zusätzlichen optischen Zugang verfügt, sodass die Information des Spinsensors ausgelesen werden kann. In verschiedenen Testexperimenten wird die Funktionsweise des gesamten Apparats demonstriert.
Um die Wirkungsgrade organischer Solarzellen weiter zu steigern, ist ein Verständnis der auftretenden Verlustmechanismen entscheidend. Im Vergleich zu anorganischen photovoltaischen Zellen sind in den organischen Halbleitern die durch Absorption erzeugten Elektron-Loch-Paare, die als Exzitonen bezeichnet werden, sehr viel stärker gebunden. Daher müssen sie an einer Heterogrenzfläche, gebildet durch ein Donator- und ein Akzeptormaterial, in freie Ladungsträger getrennt werden. Mit dem erforderlichen Transportweg an die Heterogrenzschicht sind Rekombinationsverluste der exzitonischen Anregungen verbunden, die aus einer Vielzahl unterschiedlicher Prozesse resultieren und einen der Hauptverlustkanäle in organischen Solarzellen darstellen.
Aus diesem Grund wird der Fokus dieser Arbeit auf die Charakterisierung und mögliche Reduzierung solcher exzitonischen Verlustmechanismen gelegt. Als Modellsystem wird dazu eine planare Bilagen-Struktur auf Basis des Donatormaterials Diindenoperylen (DIP) und des Akzeptors Fulleren C60 verwendet. Durch die Kombination von elektrischen und spektroskopischen Messmethoden werden unterschiedliche exzitonische Verlustmechanismen in den aktiven Schichten charakterisiert und die zugrunde liegenden mikroskopischen Ursachen diskutiert. Dazu wird zuerst auf die strukturellen, optischen und elektrischen Eigenschaften von DIP/C60-Solarzellen eingegangen. In einem zweiten Abschnitt werden die mikroskopischen Einflüsse einer Exzitonen blockierenden Lage (EBL, exciton blocking layer) aus Bathophenanthrolin (BPhen) durch eine komplementäre Charakterisierung von Photolumineszenz und elektrischen Parametern der Solarzellen untersucht, wobei auch die Notwendigkeit der EBL zur Unterbindung von Metalleinlagerungen in den aktiven organischen Schichten analysiert wird. Die anschließende Studie der Intensitäts- und Temperaturabhängigkeit der j(U)-Kennlinien gibt Aufschluss über die intrinsischen Zellparameter sowie die Rekombinationsmechanismen von Ladungsträgern in den aktiven Schichten. Ferner werden durch temperaturabhängige spektroskopische Untersuchungen der Photo- und Elektrolumineszenz der Solarzellen Informationen über die elektronischen Zustände der DIP-Schicht erlangt, die für Rekombinationsverluste der generierten Exzitonen verantwortlich sind. Zusätzlich werden Raman-Messungen an den Solarzellen und Einzelschichten diskutiert. In einer abschließenden Studie werden exzitonische Verluste unter Arbeitsbedingungen der Solarzelle durch Ladungsträgerwechselwirkungen in der Donator-Schicht quantifiziert. In dieser Arbeit konnten verschiedene relevante Verlustprozesse in organischen Solarzellen reduziert werden. Durch die Identifizierung der mikroskopischen Ursachen dieser Verluste wurde eine wichtige Voraussetzung für eine weitere Steigerung der Leistungseffizienz geschaffen.
This work sheds light on different aspects of the silicon vacancy in SiC:
(1) Defect creation via irradiation is shown both with electrons and neutrons. Optical properties have been determined: the excitation of the vacancy is most efficient at excitation wavelengths between 720nm and 800nm. The PL decay yields a characteristic excited state lifetime of (6.3±0.6)ns.
(2) Defect engineering, meaning the controlled creation of vacancies in SiC with varying neutron fluence. The defect density could be engineered over eight orders of magnitude. On the one hand, in the sample with highest emitter density, the huge PL signal could even be enhanced by factor of five via annealing mechanisms. On the other hand, in the low defect density samples, single defects with photostable room temperature NIR emission were doubtlessly proven. Their lifetime of around 7ns confirmed the value of the transient measurement.
(3) Also electrical excitation of the defects has been demonstrated in a SiC LED structure.
(4) The investigations revealed for the first time that silicon vacancies can even exist SiC nanocrystals down to sizes of about 60 nm. The defects in the nanocrystals show stable PL emission in the NIR and even magnetic resonance in the 600nm fraction.
In conclusion, this work ascertains on the one hand basic properties of the silicon vacancy in silicon carbide. On the other hand, proof-of-principle measurements test the potential for various defect-based applications of the vacancy in SiC, and confirm the feasibility of e.g. electrically driven single photon sources or nanosensing applications in the near future.
Ziel dieser Arbeit war es, das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung mittels der MRT darzustellen. Um trotz der niedrigen Protonendichte der Lunge und der geforderten hohen Auflösung ausreichend Signal für eine verlässliche Diagnostik zu erhalten, sind Aufnahmezeiten von einigen Minuten nötig. Um die Untersuchung für den Patienten angenehmer zu gestalten oder auf Grund der eingeschränkten Fähigkeit eines Atemstopps überhaupt erst zu ermöglichen, war eine Anforderung, die Aufnahmen in freier Atmung durchzuführen. Dadurch entstehen allerdings Bewegungsartefakte, die die Diagnostik stark beeinträchtigen
und daher möglichst vermieden werden müssen. Für eine Bewegungskompensation
der Daten muss die auftretende Atembewegung detektiert werden. Die Bewegungsdetektion
kann durch externe Messgeräte (Atemgurt oder Spirometer) oder durch eine
zusätzliche Anregungen erfolgen (konventionelle Navigatoren) erfolgen. Nachteile
dieser Methoden bestehen darin, dass die Bewegung während der Atmung nicht
direkt verfolgt wird, dass elektronische Messgeräte in die Nähe des Tomographen
gebracht werden und das die Patienten zusätzlich vorbereitet und eingeschränkt
werden. Des Weiteren erfordert eine zusätzliche Anregung extra Messzeit und kann
unter Umständen die Magnetisierung auf unterwünschte Weise beeinflussen.
Um die angesprochenen Schwierigkeiten der Bewegungsdetektion zu umgehen,
wurden in dieser Arbeit innerhalb einer Anregung einer 3d FLASH-Sequenz sowohl
Bilddaten- als auch Navigatordaten aufgenommen. Als Navigator diente dabei das
nach der Rephasierung aller bildgebenden Gradienten entstehende Signal (DC Signal).
Das DC Signal entspricht dabei der Summe aller Signale, die mit einem bestimmten
Spulenelement detektiert werden können. Bewegt sich beispielsweise die Leber
bedingt durch die Atmung in den Sensitivitätsbereich eines Spulenelementes, wird
ein stärkeres DC Signal detektiert werden. Je nach Positionierung auf dem Körper
kann so die Atembewegung mit einzelnen räumlich lokalisierten Spulenelementen
nachverfolgt werden. Am DC Signalverlauf des für die Bewegungskorrektur ausgewählten
Spulenelementes sind dann periodische Signalschwankungen zu erkennen.
Zusätzlich können aus dem Verlauf Expirations- von Inspirationszuständen unterschieden
werden, da sich Endexpirationszustände im Regelfall durch eine längere
Verweildauer auszeichnen.
Grundsätzlich kann das DC Signal vor oder nach der eigentlichen Datenaufnahme
innerhalb einer Anregung aufgenommen werden. Auf Grund der kurzen Relaxationszeit
T∗2 des Lungengewebes fällt das Signal nach der RF Anregung sehr schnell ab. Um
möglichst viel Signal zu erhalten sollten, wie in dieser Arbeit gezeigt wurde, innerhalb einer Anregung zuerst die Bilddaten und danach die Navigatordaten aufgenommen
werden. Dieser Ansatz führt zu einer Verkürzung der Echozeit TE um 0.3 ms und
damit zu einem SNR Gewinn von etwa 20 %. Gleichzeitig ist das verbleibende Signal
nach der Datenakquisition und Rephasierung der bildgebenden Gradienten noch
ausreichend um die Atembewegung zu erfassen und somit eine Bewegungskorrektur
der Daten (Navigation) zu ermöglichen.
Um eine retrospektive Bewegungskorrektur durchführen zu können, müssen Akzeptanzbedingungen
(Schwellenwerte) für die Datenauswahl festgelegt werden. Bei
der Wahl des Schwellenwertes ist darauf zu achten, dass weder zu wenige noch zu
viele Daten akzeptiert werden. Akzeptiert man sehr wenige Daten, zeichnen sich die
Rekonstruktionen durch einen scharfen Übergang zwischen Lunge und Diaphragma
aus, da man sehr wenig Bewegung in den Rekonstruktionen erlaubt. Gleichzeitig
erhöht sich allerdings das Risiko, dass nach der Navigation Linien fehlen. Dies führt
zu Einfaltungsartefakten, die in Form von gestörten Bildintensitäten in den Rekonstruktionen
zu sehen sind und die diagnostische Aussagekraft einschränken. Um
Einfaltungsartefakte zu vermeiden sollte der Schwellenwert so gewählt werden, dass
nach der Datenauswahl keine Linien fehlen. Aus dieser Anforderung lässt sich ein
maximaler Schwellenwert ableiten. Akzeptiert man dagegen sehr viele Daten, zeichnen
sich die Rekonstruktionen durch erhöhtes Signal und das vermehrte Auftreten
von Bewegungsartefakten aus. In diesem Fall müsste der Arzt entscheiden, ob Bewegungsartefakte
die Diagnostik zu stark beeinflussen. Wählt man den Schwellenwert
so, dass weder Linien fehlen noch zu viel Bewegung erlaubt wird, erhält man Rekonstruktionen
die sich durch einen scharfen Diaphragmaübergang auszeichnen und in
denen noch kleinste Gefäße auch in der Nähe des Diaphragmas deutlich zu erkennen
sind. Hierfür haben sich Schwellenwerte, die zu einer Datenakzeptanz von ca. 40 %
führen als günstig erwiesen.
Um Einfaltungsartefakte auf Grund der retrospektiven Datenauswahl zu verhindern,
muss das Bildgebungsvolumen mehrfach abgetastet werden. Dadurch wird
gewährleistet, dass für die letztendliche Rekonstruktion ausreichend Daten zur Verfügung
stehen, wobei mehrfach akzeptierte Daten gemittelt werden. Dies spielt auf
Grund der niedrigen Protonendichte der Lunge eine wesentliche Rolle in der Rekonstruktion
hochaufgelöster Lungendatensätze. Weiterhin führt das Mitteln von
mehrfach akzeptierten Daten zu einer Unterdrückung der sogenannten Ghost Artefakte,
was am Beispiel der Herzbewegung in der Arbeit gezeigt wird.
Da die Messungen unter freier Atmung durchgeführt werden und keine zusätzlichen
externen Messgeräte angeschlossen werden müssen, stellte die Untersuchung
für die Patienten in dieser Arbeit kein Problem dar. Im ersten Teil dieser wurde Arbeit
gezeigt, dass sich mit Hilfe des DC Signales als Navigator und einer retrospektiven
Datenauswahl das gesamte Lungenvolumen in hoher dreidimensionaler Auflösung
von beispielsweise 1.6 x 1.6 x 4 mm3 innerhalb von 13 min. darstellen lässt. Die Anwendbarkeit der vorgestellten Methode zur Bewegungskorrektur wurde neben
Probanden auch an Patienten demonstriert.
Da wie bereits beschrieben das Bildgebungsvolumen mehrfach abgetastet werden
muss, wiederholt sich auch die Abfolge der für die Bildgebung verantwortlichen
Gradienten periodisch. Da sich der Atemzyklus aber auch periodisch wiederholt,
kann es zu Korrelationen zwischen der Atmung und den wiederholten Messungen
kommen. Dies führt dazu, dass auch nach vielen wiederholten Messungen immer
noch größere Bereiche fehlender Linien im k-Raum bleiben, was zu Artefakten in
den Rekonstruktionen führt. Dies konnte im Falle der konventionellen Bewegungskorrektur
in den Gatingmasken, die die Verteilung und Häufigkeit der einzelnen
akzeptierten Phasenkodierschritte im k-Raum zeigen, beobachtet werden.
Da eine vorsätzliche Unterbrechung der Atemperiodizität (der Patient wird dazu
angehalten, seine Atemfrequenz während der Messung absichtlich zu variieren) zur
Vermeidung der angesprochenen Korrelationen nicht in Frage kommt, musste die
Periodizität in der Datenaufnahme unterbrochen werden. In dieser Arbeit wurde
dies durch eine quasizufällige Auswahl von Phasen- und Partitionskodiergradienten
erreicht, da Quasizufallszahlen so generiert werden, dass sie unabhängig von ihrer
Anzahl einen Raum möglichst gleichförmig ausfüllen. Die quasizufällige Datenaufnahme
führt deshalb dazu, das sowohl akzeptierte als auch fehlende Linien nach der
Bewegungskorrektur homogen im k-Raum verteilt auftreten.
Vergleicht man das auftreten von Ghosting zeichnen sich die quasizufälligen Rekonstruktionen
im Vergleich zur konventionellen Datenaufnahme durch eine verbesserte
Reduktion von Ghost Artefakten aus. Dies ist auf die homogene Verteilung mehrfach
akzeptierter Linien im k-Raum zurückzuführen. Die homogenere Verteilung von
fehlenden Linien im k-Raum führt weiterhin zu einer wesentlich stabileren Rekonstruktion
fehlender Linien mit parallelen MRT-Verfahren (z.B. iterativem Grappa).
Dies wird umso deutlicher je höher der Anteil fehlender Linien im k-Raum wird. Im
Falle der konventionellen Datenaufnahme werden die zusammenhängenden Bereiche
fehlender Linien immer größer, was eine erfolgreiche Rekonstruktion mit iterativem
Grappa unmöglich macht. Im Falle der quasizufälligen Datenaufnahme dagegen
können auch Datensätze in denen 40% der Linien fehlen einfaltungsartefaktfrei
rekonstruiert werden.
Im weiteren Verlauf der Arbeit wurde gezeigt, wie die Stabilität der iterativen Grappa
Rekonstruktion im Falle der quasizufälligen Datenaufnahme für eine erhebliche
Reduktion der gesamten Messzeit genutzt werden kann. So ist in einer Messzeit von
nur 74s die Rekonstruktion eines artefaktfreien und bewegungskorrigierten dreidimensionalen
Datensatzes der menschlichen Lunge mit einer Auflösung von 2 x 2 x
5 mm3 möglich. Des Weiteren erlaubt die quasizufällige Datenaufnahme in Kombination
mit iterativem Grappa die Rekonstruktion von Datensätzen unterschiedlicher
Atemphasen von Inspiration bis Expiration (4D Bildgebung). Nach einer Messzeit
von 15min. wurden 19 unterschiedliche Atemzustände rekonstruiert, wobei sich der Anteil der fehlenden Linien zwischen 0 und 20 % lag. Im Falle der konventionellen
Datenaufnahme wäre eine wesentlich längere Messzeit nötig gewesen, um ähnliche
Ergebnisse zu erhalten.
Zum Schluss soll noch ein Ausblick über mögliche Weiterentwicklungen und Anwendungsmöglichkeiten,
die sich aus den Erkenntnissen dieser Arbeit ergeben haben,
gegeben werden. So könnte das quasizufällige Aufnahmeschema um eine Dichtegewichtung
erweitert werden. Hierbei würde der zentrale k-Raum Bereich etwas
häufiger als die peripheren Bereiche akquiriert werden. Dadurch sollte die iterative
Grappa Rekonstruktion noch stabiler funktionieren und Ghost Artefakte besser reduziert
werden. Die Verteilung der Linien sollte allerdings nicht zu inhomogen werden,
um größere Lücken im k-Raum zu vermeiden.
Darüber hinaus könnte die vorgestellte Methode der Bewegungskompensation
auch für die Untersuchung anderer Organe oder Körperteile verwendet werden.
Voraussetzung wäre lediglich das Vorhandensein dezidierter Spulenanordnungen,
mit denen die Bewegung nachverfolgt werden kann. So ist beispielsweise eine dynamische
Bildgebung des frei und aktiv bewegten Knies möglich, wobei zwischen
Beugung und Streckung durch die erste Ableitung des zentralen k-Raum Signales
unterschieden werden kann. Dies kann zusätzliche Diagnoseinformationen liefern
oder für Verlaufskontrollen nach Operationen benutzt werden [15].
Eine Weiterentwicklung mit hohem klinischen Potential könnte die Kombination
der in dieser Arbeit vorgestellten retrospektiven Bewegungskorrektur mit einer Multi-
Gradienten-Echo Sequenz darstellen. Hierzu musste die bestehende Sequenz lediglich
um eine mehrfache Abfolge von Auslesegradienten innerhalb einer Anregung erweitert
werden. Dies ermöglicht eine bewegungskorrigierte voxelweise Bestimmung der
transversalen Relaxationszeit T∗2 in hoher räumlicher Auflösung. Unter zusätzlicher
Sauerstoffgabe kann es zu einer Veränderung von T∗2 kommen, die auf den sogenannten
BOLD Effekt (Blood Oxygen Level Dependent) zurückzuführen ist. Aus dieser
Änderung könnten Rückschlüsse auf hypoxische Tumorareale gezogen werden. Da
diese eine erhöhte Strahlenresistenz aufweisen, könnte auf diese Bereiche innerhalb
des Tumors eine erhöhte Strahlendosis appliziert und so möglicherweise Behandlungsmisserfolge
reduziert werden. Gleichzeitig kann durch die 4D Bildgebung eine
mögliche Tumorbewegung durch die Atmung erfasst und diese Information ebenfalls
in der Bestrahlungsplanung benutzt werden. Die Lungen MRT könnte somit um eine
hochaufgelöste dreidimensionale funktionelle Bildgebung erweitert werden.
This thesis focuses on the investigation of the electronic structure of amino acids and
salts in aqueous solution using X-ray spectroscopic methods. Both material groups are
of fundamental importance with regards to many physiological reactions, especially
for the Hofmeister effect which describes the solubility of proteins in salt solutions.
Hence, the investigation of the electronic structure of amino acids and the influence of
ions on the hydrogen bonding network of liquid water are important milestones to a
deeper understanding of the Hofmeister series.
Besides investigating the electronic structure of amino acids in aqueous solution,
the spectra were used to develop a building block model of the spectral fingerprints of
the functional groups and were compared to spectral signatures of suitable reference
molecules. In the framework of this thesis, it is shown that the building block approach
is a useful tool with allows the interpretation of spectral signatures of considerably
more complex molecules
In this work, the focus lies on the investigation of the occupied and unoccupied
electronic states of molecules in solid state, as well as in aqueous solution. Hereby,
different X-ray spectroscopic methods were applied. X-ray emission spectroscopy
(XES) was used to probe the occupied electronic structure of the solution, while the
unoccupied electronic structure was addressed by using X-ray absorption spectroscopy
(XAS). Finally, resonant inelastic X-ray scattering (RIXS) as a combination of XAS
and XES measurements provides the combined information about the unoccupied and
occupied molecular levels. The element specific character of the three measurement
methods is a feature which allows the investigation of the local electronic structure of
a single functional group. With RIXS, also non-equivalent atoms of the same element
can be addressed separately.
Within this thesis firstly, a library of the XE spectra of all 20 proteinogenic amino
acids in zwitterionic form is presented. From this sample-set XES fingerprints of
the protonated alpha-amino group NH3+ and the deprotonated carboxylic group COO- were evaluated and used to identify the XES fingerprints of the nitrogen and oxygen
containing functional groups of the side chains of the amino acids. The data is discussed
based on a building block approach. Furthermore, the XE spectra of the functional
groups of lysine and histidine, namely the NH2 group and the C3N2H4 ring structure,
are both compared to XE spectra of suitable reference molecules (imidazole, ammonia
and methylamine). It is found that the XE and RIXS spectra of the side chains of lysine
and histidine show large similarities to the XE spectra of the reference molecules. This
agreement in the XE and RIXS spectra allows a qualitative investigation of XE and
RIXS spectra of more complex amino acids using the XE and RIXS spectra of suitable
reference molecules.
The chemical structure of histidine and proline is quite different from the structures
of the other proteinogenic amino acids. Due to the unique chemical structure of
the side chain which in both cases consists of a heterocyclic ring structure, these two
amino acids were investigated in more detail. Zubavichus et al. [1] have shown that
amino acids are decomposing while exposed to X-ray radiation of the experiment. The
damage is irreversible and molecular fragments can adsorb on the membrane of the
experimental setup. This contamination can also create a spectral signature which
then overlaps with the signal of the solution and which complicates the interpretation
of the data. To record spectra which are free from contributions of adsorbed molecular
fragments on the membrane, the adsorption behavior was investigated.
In contrast to the solid phase in which the amino acids are present as salts in one
electronic conformation, the charge state of the amino acids can be manipulated in
aqueous solution by tuning the pH-value. By doing this, all possible charge states are
accessible (cation, anion, zwitterion). In this work it is shown that also the spectra
of the different charge states can be modeled by the spectra of suitable reference
molecules using the building block approach. The spectral changes occurring upon
protonation and deprotonation of the functional groups are explored and verified by
comparing them to theoretical calculations.
The comparison with measurements of pyrrolidine show that the electronic structure
which surrounds the nitrogen atom of proline is strongly influenced by the
ring structure of the side chain. Furthermore, the proline, pyrrolidine, and histidine
molecules are also degrading during the liquid sample measurements. This can be
observed by the detection of a new spectral component which increases with the
measurement time originating from the window membrane. In all cases, the speed of
the agglomeration of molecular fragments at the membrane was observed to be highly
sensitive to the pH value of the solution.
To understand the Hofmeister series, also the impact of the salt ions have to be
investigated. In this study the influence of potassium chloride (KCl) on the hydrogen
bond network of water was studied by using non-resonantly excited XES as well as
RIXS. A decreased dissociation of hydrogen molecules and changes in the molecular
vibrations could be detected. These changes were interpreted with a molecular
reorganization of the water molecules and a decreased number of hydrogen bonds.
Ziel dieser Arbeit ist es, ein verbessertes Verständnis für den Zusammenhang zwischen mechanischer Steifigkeit und Wärmetransport über das Festkörpergerüst bei hochporösen Materialien zu erlangen. Im Fokus dieser Arbeit steht die Fragestellung, wie mechanische Steifigkeit und Wärmeleitfähigkeit bei hochporösen Materialien miteinander zusammenhängen und ob es möglich ist, diese beiden Eigenschaften durch geometrische Modifikationen der Mikrostruktur unabhängig voneinander zu verändern. Die durchgeführten Untersuchungen haben gezeigt, dass ein Großteil der mikrostrukturellen Modifikationen beide Materialeigenschaften beeinflussen und die mechanische Steifigkeit in der Regel eng mit dem Wärmetransport über das Festkörpergerüst verknüpft ist. Es konnte jedoch auch nachgewiesen werden, dass die mechanische Steifigkeit bei hochporösen Materialien nicht eindeutig mit dem Wärmetransport über das Festkörpergerüst zusammenhängt und spezifische mikrostrukturelle Modifikationen einen stärkeren Einfluss auf die mechanische Steifigkeit besitzen, als auf den Wärmetransport über das Festkörpergerüst. Umgekehrt ist diese Aussage nicht ganz so eindeutig.
Die theoretische Betrachtung des Zusammenhangs zeigt, dass in die Berechnung der mechanischen Steifigkeit teils andere geometrische Strukturgrößen einfließen, als in die Berechnung des Wärmetransports über das Festkörpergerüst, so dass die mechanische Steifigkeit unabhängig von der Wärmeleitfähigkeit verändert werden kann. Es zeigt sich jedoch auch, dass die meisten strukturellen Veränderungen beide Eigenschaften beeinflussen und die mechanische Steifigkeit aufgrund der Biegedeformation der Netzwerkelemente systematisch stärker auf strukturelle Veränderungen reagiert als die Wärmeleitfähigkeit der Struktur, so dass die mechanische Steifigkeit in der Regel quadratisch mit der Wärmeleitfähigkeit des Festkörpergerüstes skaliert. Mit den Methoden der effective-media-theory lassen sich Grenzen ermitteln, innerhalb derer sich mechanische Steifigkeit und Wärmeleitfähigkeit unabhängig voneinander variieren lassen.
Im experimentellen Teil der Arbeit wurden Probenserien von Polyurethan-Schäumen, Polyurea Aerogelen und organisch / anorganischen Hybrid Aerogelen herangezogen, so dass poröse Materialien mit geordneten, voll vernetzten Mikrostrukturen, mit statistisch isotropen, teilvernetzen Mikrostrukturen, sowie Mikrostrukturen mit anisotropen Charakter in die Untersuchung einbezogen werden konnten. Als Struktureigenschaften, die die mechanische Steifigkeit ungewöhnlich stark beeinflussen, konnten die Regelmäßigkeit der Struktur und der Krümmungsradius der Netzwerkelemente sicher identifiziert werden. Alle weiteren strukturellen Veränderungen führen zu dem annähernd quadratischen Zusammenhang.
In einem dritten Abschnitt dieser Arbeit wird das vereinfachte Phononendiffusionsmodell herangezogen, um den Zusammenhang zwischen mechanischer Steifigkeit und Wärmetransport über das Festkörpergerüst bei Aerogelen grundlagenphysikalisch zu modellieren. Zur Diskussion werden die experimentell ermittelten Eigenschaften der isotropen Polyurea Aerogele herangezogen und eine qualitative Modellierung ihrer Schwingungszustandsdichten durchgeführt. Es konnte gezeigt werden, dass die Kombination aus Probendichte und Schallgeschwindigkeit, mit der sich die mechanische Steifigkeit berechnen lässt, unter bestimmten Randbedingungen auch die Energie und Transporteigenschaften der Phononen beschreibt, die den Wärmetransport über das Festkörpergerüst bei Aerogelen bestimmen.
Die Ergebnisse dieser Arbeit lassen sich zum Beispiel heranziehen, um die Eigenschaften hochporöser Materialien für eine gegebene Anwendung durch mikrostrukturelle Modifikationen optimal zu gestalten.
Das Ziel der Promotion war die Entwicklung eines Flusssensors mit dem Fokus auf Flussmessungen an Pflanzen. Dazu musste zunächst die Hardware in Form eines räumlich zugänglichen Magneten und einer Sende- und Empfangseinheit entworfen werden. Um die MR-Konsole ansteuern zu können, musste eine Software entwickelt werden. Die AC-Methode wurde für Flussmessungen mit niedrigen Geschwindigkeiten angepasst und die entsprechende Theorie dazu erweitert. Mit dieser weiterentwickelten AC-Methode wurde die Flussmessung an Pflanzen demonstriert. Dafür wurden im Rahmen einer Kooperation mit der Arbeitsgruppe „Lipid Motobolism“ der IPK-Gatersleben Flussstudien an Weizenpflanzen durchgeführt. Darüber hinaus wurde in dieser Arbeit eine neue Technik zur Wirbelstromvermeidung bei Permanentmagneten entwickelt, um Problemen mit diesen bei Flussmessungen entgegenzuwirken.
Sensorbau
Es wurde ein zugänglicher, mobiler Magnet mit einer Feldstärke von 0,42 T gebaut. Die Feldhomogenität beträgt 0,5 ppm in 1 cm³. Im Vergleich zu dem am Lehrstuhl der EP5 bestehenden, geschlossenen, mobilen Magnetsystem erreicht das in dieser Arbeit gebaute System ein 40fach homogeneres Magnetfeld. Erzielt wurden diese Verbesserungen durch ein spezielles Design, welches durch Computersimulationen sukzessiv optimiert wurde. Durch angepasste Polschuhe konnte darüber hinaus die Induktion von Wirbelströmen im Mittel um einen Faktor 7 reduziert werden, wodurch phasensensitive Flussmessungen ermöglicht wurden.
Um die Zugänglichkeit zu dem Innenraum der HF-Spulen zu gewährleisten, wurde eine Klappspule weiterentwickelt und als Sende- und Empfangseinheit für den Tomographen gebaut. Ferner wurde ein System gebaut, dass direkt um die Pflanze gewickelt werden kann und sich somit für besonders dünne Pflanzenstängel eignet.
Weiterhin wurden zwei Systeme zur Rauschunterdrückung für die Messungen an Pflanzen entwickelt. Dadurch konnte das Rauschen um einen Faktor 92 gesenkt werden. Dies war notwendig, weil die länglichen Pflanzen durch ihre Ausdehnung über das Gehäuse hinweg ein Rauschen in die Empfangsspule induziert haben. Die beiden Rauschunterdrückungssysteme, die elektrische Schirmung und die Gleichtaktunterdrückung, entfernten das Rauschen dabei gleichermaßen.
Flussmessung
Die im Rahmen der Arbeit erfolgte Weiterentwicklung der AC-Methode [102] erlaubte es erstmals mit der Methode quantitative Flussprofile aufzunehmen. In Folge dessen war es
außerdem möglich Geschwindigkeiten unter 200 µm/s zu messen. Die Vorrausetzung dafür war die Implementierung von trapezförmigen Gradienten, welche kürzere Rampzeiten und eine stärkere Kodierung zulassen. Dadurch sind außerdem Intervalle ohne Gradienten realisierbar, die effizientere Refokussierungspulse und die Aufnahme mehrerer Datenpunkte ermöglichen. Die zu erwartenden und simulierten Flussprofile entsprachen den gemessenen Profilen durch die Verwendung einer neuen Auswertungstechnik.
Die neu entwickelte Erweiterung zur Bildgebung ermöglicht die ortsaufgelöste, spektroskopische Flussmessung und so können die Bereiche von Xylem und Phloem voneinander getrennt werden. Dies wurde durch Messungen einer Schwarzerle gezeigt, bei der die im Abschnitt 5.1 beschriebene Struktur dikotyler Pflanzen aufgelöst werden konnte. Zusätzlich können qualitativ genauere Aussagen über die Flussgeschwindigkeit getroffen werden.
Bei Messungen an Pflanzen konnte mit der optimierten AC-Methode die Flussänderungen aufgrund äußerer Einflüsse, wie der Beleuchtung, beobachtet werden. Langzeitmessungen über 9 Tage zeigten einen der Beleuchtung folgenden Flussverlauf - auch bei sehr geringen mittleren Flussänderungen von unter 200 µm/s.
Bloch-Siegert Phasenkodierung
Um eine Phasenkodierung ohne die Induktion von Wirbelströmen zu erhalten, wurde im Rahmen der Arbeit die ortsabhängige Phasenkodierung mittels B1-Gradienten entwickelt. Diese Technik basiert auf HF-Wechselfeldern und benutzt den sogenannten BS-Shift um einen B1-feldabhängigen Frequenzshift zu induzieren. Zwei Rekonstruktionstechniken wurden entwickelt, um die Rekonstruktion von entzerrten Bildern zu ermöglichen. Dies war notwendig, da die Kodierung mittels BS-Shift von B1² abhängt. Infolgedessen wird bei der Verwendung von konstanten HF-Gradienten eine vom Quadrat des Ortes abhängige Phasenkodierung induziert. Als Alternative zu diesem Verfahren wurde ein Gradient entwickelt, der einen wurzelförmigen Feldverlauf hat und somit die lineare Kodierung ohne angepasste Rekonstruktionstechniken ermöglicht.
In dieser Arbeit werden für die Anwendung in der menschlichen Lunge
optimierte Methoden zur Bestimmung von T1- und T2*-Karten diskutiert:
Dc-Gating ermöglicht die Quantifizierung in freier Atmung, wobei für die
T1-Quantifizierung mittels Inversion Recovery eine Korrektur des dc-Signals
entwickelt wurde. Dies hat den Vorteil, dass Parameterkarten aus mehreren
Messungen anhand ihrer dc-Signale passend überlagert werden können. Da T1
und T2* auf unterschiedliche Art und Weise von der Sauerstoffkonzentration
abhängen, verbessert dies die Möglichkeit, ΔT1- und ΔT2*- Differenzkarten aus
Messungen mit unterschiedlichen O2-Konzentrationen im Atemgas zu erstellen.
Die Parameterquantifizierung ist in erster Linie für die Beobachtung von
Krankheitsverläufen interessant, da T1 und T2* absolute, vergleichbare Zahlen
sind. Da T2* deutlich vom Atemzustand abhängt, ist es auch hierfür sinnvoll,
durch Gating identische Atemzustände abzubilden. Um die unterschiedlichen
Einflüsse des Sauerstoffs auf T1 und T2* besser vergleichbar zu machen, wurde
in dieser Arbeit weiterhin eine kombinierte Messung für beide Parameter
implementiert: Da auch diese in freier Atmung stattfindet, profitieren nicht
nur die Differenzkarten von der Überlagerung der Bilder, sondern auch der
Vergleich der ΔT1- und ΔT2*-Karten untereinander.
Messungen mit einer konventionellen kartesischen Methode an COPD-Patienten
unter Raumluft- und 100% Sauerstoffatmung ergaben bei Verwendung identischer
Atemmasken ein deutlich geringeres ΔT1 als in gesunden Probanden. Dass T1 in
der Lunge nicht nur von der Sauerstoffkonzentration sondern auch von der
Gewebezusammensetzung und insbesondere auch dem Blutvolumenanteil abhängt,
zeigte sich hierbei aber auch an den bei COPD im Mittel sehr viel kürzeren
T1-Zeiten bei Raumluft. Die aufgrund emphysematischer Veränderung noch
zusätzlich reduzierte Protonendichte im Parenchym kranker Lungen macht diese
Messungen allerdings besonders schwierig.
Die oben erwähnten Optimierungen der T1-Quantifizierung zielen daher auch
darauf ab, das Signal aus der Lunge zu maximieren, um Patientenmessungen
einfacher zu machen: Messungen in freier Atmung sind für Patienten nicht nur
einfacher, sondern erlauben effektiv auch längere Messzeiten. Insbesondere
wurde aber durch die Entwicklung einer radialen Methode die Echozeit zur
Messung reduziert, um die kurze T2*-Zeit in der Lunge auszugleichen.
Schließlich wurde durch Implementation einer 2D UTE Sequenz die Messung bei
der kürzesten vom Scanner erlaubten Echozeit ermöglicht.
Die Messungen bei ultrakurzen Echozeiten in Probanden zeigten allerdings
deutlich kürzere T1-Zeiten als die zuvor gefundenen oder in der Literatur
dokumentierten. In weiteren Experimenten wurde das sichtbare T1 zu mehreren
Echozeiten mit Hilfe der zur kombinierten Quantifizierung entwickelten
Methode bestimmt. Dabei ergab sich eine Zunahme des gemessenen T1 mit der
Echozeit. Aus diesem Verhalten sowie den gefundenen kürzesten und längsten T1
lässt sich schließen, dass das intra- und extravaskuläre Lungenwasser, also
Blut bzw. das umgebende Gewebe, mit unterschiedlichen T1- und T2*-Zeiten zum
Signal und damit auch dem effektiven T1 beitragen.
Dass das TE der Messung die Gewichtung dieser Kompartimente bestimmt, hat
dabei mehrere Auswirkungen: Einerseits bedeutet dies, dass beim Vergleich von
T1-Messungen in der Lunge stets auch das TE mitbetrachtet werden muss, bei
dem diese durchgeführt wurden. Andererseits lässt sich die Möglichkeit, die
Messung auf die unterschiedlichen Kompartimente abzustimmen, potentiell
ausnutzen, um zusätzliche diagnostische Informationen zu gewinnen: Da T1 vom
Blutvolumenanteil und der Gewebezusammensetzung abhängt, könnte dieser Effekt
helfen, diese beiden Einflüsse zu differenzieren.
Während die in dieser Arbeit beschriebenen Experimente die TE-Abhängigkeit
des sichtbaren T1 in Probanden aufzeigen, liefern sie allerdings noch keine
genaue Erklärung für die möglichen Ursprünge dieses Effekts. Um diese weiter
zu untersuchen, könnten allerdings gezielte Phantom- und in vivo-Experimente
Aufschluss geben: Ein Aufbau, der die Feldverzerrung durch luftgefüllte
Alveolen in Lösungen mit entsprechenden verschiedenen Suszeptibilitäten
nachbildet, reduziert den Unterschied zwischen den Kompartimenten auf T1 und
χ. Eine in vivo-Messung mit möglichst großer Differenz zwischen Ex- und
Inspiration hingegen könnte den Einfluss der Abstände der Kompartimente vom
Gasraum aufzeigen, da die Alveolarwände in tiefer Inspiration am weitesten
gedehnt und daher am dünnsten sind.
Topological insulators belong to a new quantum state of matter that is currently one of
the most recognized research fields in condensed matter physics. Strained bulk HgTe
and HgTe/HgCdTe quantum well structures are currently one of few topological insulator
material systems suitable to be studied in transport experiments. In addition
HgTe quantum wells provide excellent requirements for the conduction of spintronic
experiments. A fundamental requirement for most experiments, however, is to reliably
pattern these heterostructures into advanced nano-devices. Nano-lithography on this
material system proves to be challenging because of inherent temperature limitations,
its high reactivity with various metals and due to its properties as a topological insulator.
The current work gives an insight into why many established semiconductor
lithography processes cannot be easily transferred to HgTe while providing alternative
solutions. The presented developments include novel ohmic contacts, the prevention
of metal sidewalls and redeposition fences in combination with low temperature
(80 °C) lithography and an adapted hardmask lithography process utilizing a sacrificial
layer. In addition we demonstrate high resolution low energy (2.5 kV) electron beam
lithography and present an alternative airbridge gating technique. The feasibility of
nano-structures on HgTe quantum wells is exemplarily verified in two separate transport
experiments. We are first to realize physically etched quantum point contacts
in HgTe/HgCdTe high mobility 2DEGs and to prove their controllability via external
top-gate electrodes. So far quantum point contacts have not been reported in TI
materials. However, these constrictions are part of many proposals to probe the nature
of the helical quantum spin Hall edge channels and are suggested as injector and
detector devices for spin polarized currents. To confirm their functionality we performed
four-terminal measurements of the point contact conductance as a function of
external gate voltage. Our measurements clearly exhibit quantized conductance steps
in 2e2/h, which is a fundamental characteristic of quantum point contacts. Furthermore
we conducted measurements on the formation and control of collimated electron beams, a key feature to realize an all electrical spin-optic device. In a second study
several of the newly developed lithography techniques were implemented to produce
arrays of nano-wires on inverted and non-inverted HgTe quantum well samples. These
devices were used in order to probe and compare the weak antilocalization (WAL) in
these structures as a function of magnetic field and temperature. Our measurements
reveal that the WAL is almost an order of magnitude larger in inverted samples. This
observation is attributed to the Dirac-like dispersion of the energy bands in HgTe quantum
wells. The described lithography has already been successfully implemented and
adapted in several published studies. All processes have been optimized to guarantee
a minimum effect on the heterostructure’s properties and the sample surface, which is
especially important for probing the topological surface states of strained HgTe bulk
layers. Our developments therefore serve as a base for continuous progress to further
establish HgTe as a topological insulator and give access to new experiments.
Magnetic resonance imaging is derogated by the presence of metal implants and image quality is impaired. Artifacts are categorized according to their sources, the differences in susceptibility between metal and tissue and the modulation of the magnetic radiofrequency (RF) transmit field. Generally, these artifacts are intensified at higher field strength. The purpose of this work is to analyze the efficiency of current methods used for metal artifact reduction at 3T and to investigate improvements. The impact of high-bandwidth RF pulses on susceptibility-induced artifacts is tested. In addition, the benefit of a two-channel transmit system with respect to shading close to total hip replacements and other elongated metal structures in parallel to the magnetic field is analyzed.
Local transmit/receive coils feature a higher peak B1 amplitude than conventional body coils and thus enable high-bandwidth RF pulses. Susceptibility-induced through-plane distortion relates reciprocally to the RF bandwidth, which is evaluated in vitro for a total knee arthroplasty. Clinically relevant sequences (TSE and SEMAC) with conventional and high RF pulse bandwidths and different contrasts are tested on eight patients with different types of knee implants. Distortion is rated by two radiologists. An additional analysis assesses the capability of a local spine transmit coil. Furthermore, B1 effects close to elongated metal structures are described by an analytical model comprising a water cylinder and a metal rod, which is verified numerically and experimentally. The dependence of the optimal polarization of the transmit B1 field, creating minimum shading, on the position of the metal is analyzed. In addition, the optimal polarization is determined for two patients; its benefit compared to circular polarization is assessed.
Phantom experiments confirm the relation of the RF bandwidth and the through-plane distortion, which can be reduced by up to 79% by exploitation of a commercial local transmit/receive knee coil at 3T. On average, artifacts are rated “hardly visible” for patients with joint arthroplasties, when high-bandwidth RF pulses and SEMAC are used, and for patients with titanium fixtures, when high-bandwidth RF pulses are used in combination with TSE. The benefits of the local spine transmit coil are less compared to the knee coil, but enable a bandwidth 3.9 times as high as the body coil. The modulation of B1 due to metal is approximated well by the model presented and the position of the metal has strong influence on this effect. The optimal polarization can mitigate shading substantially.
In conclusion, through-plane distortion and related artifacts can be reduced significantly by the application of high-bandwidth RF pulses by local transmit coils at 3T. Parallel transmission offers an option to substantially reduce shading close to long metal structures aligned with the magnetic field. Effective techniques dedicated for metal implant imaging at 3T are introduced in this work.
Der Fokus dieser Arbeit liegt in der Untersuchung des exzitonischen Transports, sowie der
Dynamik exzitonischer Zustände in organischen Halbleitern. Als fundamentale Fragestellung werden die inhärenten, materialspezifischen Parameter untersucht, welche Einfluss auf die Exzitonen-Diffusionslänge besitzen. Sowohl der Einfluss der strukturellen Ordnung als auch die fundamentalen exzitonischen Transporteigenschaften in molekularen Schichten werden anhand der archetypischen, morphologisch unterschiedlichen organischen Halbleiter Diindenoperylen (DIP), sowie dessen Derivaten, α-6T und C60 studiert. Die resultierende Filmbeschaffenheit wird mittels Röntgendiffraktometrie (XRD) und Rasterkraftmikroskopie (AFM) analysiert, welche Informationen über die Morphologie, die strukturelle Ordnung und die Mikrostruktur der jeweiligen molekularen Schichten auf verschiedenen Längenskalen liefern.
Um Informationen über die Exzitonen-Diffusion und die damit einhergehende Exzitonen-
Diffusionslänge LD zu erhalten, wurde die Methode des Photolumineszenz (PL)-Quenchings
gewählt. Um umfassende Informationen zur Exzitonen-Bewegung in molekularen Dünnschichten zu erhalten, wurde mit Hilfe der Femtosekunden-Transienten-Absorptionsspektroskopie (TAS) und der zeitkorrelierten Einzelphotonenzählung (TCSPC) die Dynamik angeregter Energiezustände und deren jeweiliger Lebensdauer untersucht. Beide Messverfahren gewähren Einblicke in den zeitabhängigen Exzitonen-Transport und ermöglichen eine Bestimmung des Ursprungs möglicher Zerfallskanäle.
Die zentralen Ergebnisse dieser Arbeit zeigen zum einen eine Korrelation zwischen LD und der strukturellen Ordnung der Schichtmorphologie, zum anderen weist die temperaturunabhängige
Exzitonen-Bewegung in hochgeordneten polykristallinen DIP-Filmen auf die Möglichkeit
der Existenz eines kohärenten Exzitonen-Transports bei tiefen Temperaturen unterhalb von 80 K hin. Zeitaufgelöste spektroskopische Untersuchungen lassen zudem auf ein breites Absorptionsband höherer angeregter Zustände schließen und weisen eine höhere Exzitonen-
Zustandsdichte in polykristallinen DIP-Schichten im Vergleich zu ungeordneten Filmen auf.
Messungen mit Magnetresonanztomographen sind seit jeher mit hohen Lautstärken verbunden. Deshalb wird das Gerät im Volksmund auch als „laute Röhre“ bezeichnet. Bisher wurde das Problem mit Kopfhörern, Ohrenstöpseln und akustischer Dämmung des MRT-Scanners angegangen. Auch in der Fachliteratur wird das Problem als gegeben angesehen und es werden kaum wissenschaftliche Lösungsansätze zur Lautstärkereduktion beschrieben.
Das Ziel der vorliegenden Arbeit war es, Bildgebungs-Sequenzen für schwer‑optimierbare Bildkontraste und sogenannte Standard-Kontraste aus dem klinischen Umfeld hinsichtlich der Lautstärke zu optimieren. Viele dieser Kontraste können bereits mit einfachen Algorithmen wie dem Gradientenglättungsalgorithmus erfolgreich in Hinblick auf die Lautstärke optimiert werden. Allerdings existieren auch Sequenzen beziehungsweise Kontraste, die aufgrund ihrer Eigenschaften nicht von einem solchen Algorithmus profitieren können. Die Optimierungen und Änderungen sollten software-seitig erfolgen, das heißt durch Änderung der Gradientenformen und Datenakquisition.
In der Arbeit wurden die grundlegenden Zusammenhänge zwischen den verwendeten Geräteparametern und der Lautstärke untersucht und zudem die physikalischen Ursachen der Lautstärkeentwicklung hergeleitet. Diese konnten anhand der Lorentz-Kräfte quantitativ beschrieben werden. Somit konnten die Hauptursachen der Lautstärkeentwicklung identifiziert werden. Diese sind abhängig von der Gradienten-Steig-Rate, aber auch von der Amplitude der Gradienten. Es konnte gezeigt werden, dass eine Minimierung dieser Gradientenparameter zu einer geringeren Lautstärkeentwicklung führt. Allerdings führt diese Minimierung in den meisten Fällen auch zu einer systematischen Verlangsamung des Sequenzablaufs, was das Erreichen bestimmter Echozeiten und Bildkontraste unmöglich macht.
Zu den problematischen Kontrasten bezüglich der Lautstärkereduktion zählten der T1- und PD‑Kontrast einer Turbo-Spin-Echo-Sequenz. Durch die Kombination von mehreren Maßnahmen, wie der Adaption der k-Raum-Akquisition, der HF-Pulse-Parameter und den Gradientenformen, war es möglich, die Lautstärke in Beispielmessungen um bis zu 16,8 dB(A) zu reduzieren. Wie bei der kürzlich veröffentlichten Methode zur Reduktion für die T2‑gewichteten Kontraste, wurde dies zulasten einer Messzeitverlängerung von bis zu 50% erreicht. Die Endlautstärke betrug dabei circa 81 dB(A). Mit der Lautstärkeoptimierung der klinisch bedeutsamen T1- und PD‑Kontraste wurde die Palette an leisen, mit der Turbo-Spin-Echo‑Sequenz erzielbaren, Standard-Kontrasten (T1, T2 und PD) nun vervollständigt.
In einem anderen Ansatz wurde die Anwendbarkeit des CAT-Konzepts auf die Lautstärkereduktion untersucht. Beim CAT-Konzept wird die Messung in Einzelmessungen mit verschiedenen Parametern unterteilt. Bisher wurde dieser Ansatz zur SAR-Reduktion verwendet. Das Zentrum des k-Raums wird mit einer SAR-intensiven, kontrastgebenden Messung aufgenommen. Der verbleibende Teil des k-Raums wird mit einer SAR-reduzierten, bildstrukturrelevanten Messung aufgenommen. In dieser Arbeit wurde die Übertragung des CAT-Konzepts auf die Lautstärkereduktion untersucht. Anstelle von SAR-intensiven und SAR‑reduzierten Messungen, wurde hier die Unterteilung in „laute“ und „leise“ Messungen untersucht. Dabei wurden Überlegungen angestellt, die es für eine Vielzahl an Messungen ermöglichen, einen großen Teil der Messung leise zu gestalten ohne die Bildqualität oder den Bildkontrast zu verändern. In einem weiteren Schritt wurden Überlegungen für die Lautstärkereduktion der lauten Messungen vorgestellt. Anschließend wurden für eine GRE- und TSE-Sequenz Optimierungsschritte evaluiert und die Lautstärke gemessen.
Der hinsichtlich der Lautstärkeoptimierung herausforderndste Bildkontrast ist die diffusionsgewichtete Bildgebung. Diese besitzt eine Diffusions-Präparation zur Sichtbarmachung der Diffusivität, bei der die maximal mögliche Gradienten-Amplitude verwendet wird. Ebenso werden nach der Präparation die Daten mit einem EPI‑Akquisitionsmodul mit Blip-Gradienten akquiriert, das mit einem charakteristischem „Pfeifton“ einhergeht. Zum einen wurden die Gradientenformen konsequent angepasst. Zum anderen wurde eine Segmentierung der k-Raum-Akquisition in Auslese-Richtung verwendet, um die Gradienten‑Steig-Raten zu reduzieren. Auch hier konnte eine deutliche Lautstärkereduktion von bis zu 20,0 dB(A) erzielt werden. Dies wurde zulasten einer Messzeitverlängerung von 27% ‑ 34% im Vergleich zur Standard-Sequenz erreicht. Durch eine weitere Messzeitverlängerung um bis zu 23% kann die Lautstärke um weitere 0,9 dB(A) reduziert werden. Dabei hängt die genaue Messzeitverlängerung vom verwendeten GRAPPA-Faktor und der Anzahl der Auslese-Segmente ab. Die entstandene Sequenz wurde in mehreren Kliniken erfolgreich erprobt.
Bisher mussten bei MRT-Messungen stets Kompromisse zwischen „hoher Auflösung“, „hohem SNR“ und „geringer Messzeit“ getroffen werden. Als Anschauung dafür wurde das „Bermuda‑Dreieck der MRT“ eingeführt. Da alle drei Größen sich gegenseitig ausschließen, muss stets ein Mittelweg gefunden werden. Einige der in dieser Arbeit erzielten Erfolge bei der Lautstärkereduktion wurden auf Kosten einer verlängerten Messzeit erreicht. Daher ist es naheliegend, das „Bermuda-Dreieck der MRT“ um die Dimension der „geringen Lautstärke“ zu einer „Bermuda-Pyramide der MRT“ zu erweitern. Damit muss die Lautstärkeentwicklung in die Mittelweg‑Findung miteinbezogen werden.
Die in dieser Arbeit erzielten Lautstärken liegen in der Größenordnung zwischen 80 ‑ 85 dB(A). Somit können Messungen bei Verwendung von Gehörschutz angenehm für den Patienten durchgeführt werden. Durch neue Techniken der Zukunft wird es wahrscheinlich sein, höhere Auflösungen, höheres SNR oder kürzere Aufnahmedauern zu erzielen, beziehungsweise stattdessen diese in eine geringe Lautstärke „umzuwandeln“.
Ebenso werden möglicherweise auf der hardware-technischen Seite Fortschritte erzielt werden, so dass in neueren MRT-Scannergenerationen mehr Wert auf die Lärmdämmung gelegt wird und somit der softwarebasierten Lautstärkereduktion einen Schritt entgegen gekommen wird. Damit könnten zukünftige Patienten-Messungen gänzlich ohne störenden Gehörschutz durchgeführt werden.
The aim of the present thesis is to explore the potential of X-ray magnetic circular dichroism(XMCD) experiments on gaining new insights into Kondo and heavy fermion materials. XMCD, which is derived from X-ray absorption spectroscopy (XAS), allows probing magnetic polarization specific to the different elements in a material and to their atomic orbitals. In particular, at the Ce M4,5 edges the method is sensitive to the localized 4f level, which provides the magnetic impurity moment responsible for Kondo physics in Ce compounds. Hence, Ce M4,5 XMCD is ideally suited to investigate local magnetism in the presence of interaction of impurity and conduction electrons in such materials.
As a model material, CePt5/Pt(111) surface intermetallics were chosen for the present study. This thin-film material can be prepared by well-defined procedures involving molecular beam epitaxy. Crystalline Ordered samples are obtained by exploiting the single-crystallinity of the Pt(111) substrate. The surface character of thin films ideally matches the probing depth of soft X-ray spectroscopy in the total electron yield mode.
The XMCD and XAS experiments, taking into account dependence on temperature, angle of incidence, sample thickness and external magnetic field, revealed the presence of four relevant energy scales that influence the magnetic response:
1. The 4f level in CePt5/Pt(111) is subject to significant crystal field (CF) splitting, which leads to reorganization of the six j = 5/2 sublevels. The hexagonal symmetry of the crystal structure conserves mj as a good quantum number. The proposed CF scheme, which is derived from measurements of the paramagnetic susceptibility by XMCD as well as linear dichroism in XAS, consists of nearly degenerate |1/2> and |3/2> doublets with the |5/2> doublet excited by E5/2 = 15 ... 25 meV.
2. Single impurity Kondo interaction significantly couples the magnetic moments of the impurity and conduction electrons. A signature thereof is the f0 -> f1 contribution to Ce M4,5 XAS, the strength of which can be tuned by control of the sample thickness. This finding is in line with the observation of reduced effective 4f moments as detected by XMCD.
3. Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction induces ferromagnetic correlations on the impurity lattice, which induces a positive Curie-Weiss temperature in the temperature-dependent inverse susceptibility.
4. Indications for the transition to a coherent heavy fermion state are found in the inverse susceptibility at T ~ 20 K; the ferromagnetic ground state is not observed. The fielddependence of the magnetic moment in the coherent state can be interpreted in terms of a metamagnetic transition. This allows studying basic characteristics of the renormalized band structure of a heavy fermion system by XMCD.
The disentanglement of these different contributions to the 4f magnetism not only required extensive Ce M4,5 XAS and XMCD data, but also a thorough structural characterization of the material, a fundamental study of the Ce M4,5 line shape in relation to the degree of 4f hybridization and the development of a model for the paramagnetic susceptibility.
The unit cell dimensions and sample morphology of CePt5/Pt(111) intermetallics were studied by low-energy electron diffraction (LEED) and scanning transmission electron microscopy (STEM). These experiments showed that well-defined intermetallic films form on top of the substrate. This lead to introduction of the film thickness t, measured in unit cells (u.c.), as a key feature to characterize the samples.
Systematic LEED measurements in the thickness range t ~ 1 ... 15 u.c. allowed identification of six different phases, which could be interpreted as resulting from the same crystal structure with different rotational alignments and lattice constants. An accurate determination of the surface lattice constant at t ~ 3 u.c. could be achieved by interpretation of additional superstructure spots as arising from a well-defined combination of substrate and film lattices. The thicknessdependence of the lateral lattice constant could be explained in terms of lattice relaxation.
Confirmation of the CePt5 stoichiometry and structure was performed by use of thicknessdependent XAS and a representative LEED-IV study. The results of this study indicate that the intermetallic films exhibit hexagonal CaCu5 structure over the entire range of thicknesses that were studied. The terminating layer consists purely of Pt with one additional Pt atom per unit cell compared to the bulk structure.
The line shape of Ce M4,5 spectra was analyzed with the help of full multiplet calculations.
Experimentally, characteristic variations of the line shape were observed with increasing f0 -> f1 contribution. The calculations show that these variations are not due to an admixture of j = 7/2 character to the ground state, as often stated in the literature. As alternatives, this observation can be explained by either considering an additional contribution to the spectrum or by assumption of an asymmetric lifetime profile.
The model that was developed for the inverse paramagnetic susceptibility contains the hexagonal crystal field, magnetic coupling of the impurity moments in a mean field scheme and Kondo screening. The latter is included phenomenologically by screening factors for the effective moment. Assumption of doublet-specific screening factors, which means that the degree of Kondo interaction depends on the mj character of the 4f sublevels, allows satisfactory reproduction of the experimental data.
Electrochemical double layer capacitors (EDLC), most commonly referred to as “supercapacitors”,
have gained increasing scientific and commercial interest in recent years. Purely electrostatic charge storage processes allow charge- and discharge cycles in the second-time scale, exhibiting a theoretical capacitance in the order of 100 F per gram of electrode material, thereby providing efficient recuperation devices for electromechanical processes, for example. Introducing electrochemically active materials such as manganese oxides into the supercapacitor electrode, allows to combine the double-layer storage with a battery-like storage process, leading to capacitance that can be up to two orders of magnitude larger than those in EDLC.
In the present work, an electroless deposition approach of manganese oxide on a carbon scaffold
is adapted and further investigated. The carbon material is derived from an organic xerogel, which in turn is prepared via a sol-gel process, allowing tailoring of the structural properties of the carbon, making it an ideal model system to study the relation between morphology and electrochemical performance in the carbon-manganese oxide hybrid electrode.
In the first part of this thesis, a variation of manganese oxide deposition time at a low concentration of precursor solution is analyzed. Mass uptakes reach up to 58 wt.%, leading to an increase of volumetric capacitance by a factor 5, however reducing the dynamic performance of the electrode.
The structural characterization gives hints on the deposition location of the active material either in the intra-particular pores of the carbon backbone or on the enveloping surface area of the particles forming the backbone.
In order to comprehensively answer the question of the location of the active material within
the hybrid electrode, the particle size of the carbon backbone and therefore the enveloping surface area of the carbon particles was varied. For samples with high mass uptakes, scanning electron microscopy (SEM) images show a layer thickness of 27 nm of active material around the carbon particles. In order to quantitatively investigate this layer morphology, even for low mass uptakes where no layer is visible in SEM images, a model interpreting data from anomalous small angle X-ray scattering (ASAXS) measurements was developed. The results confirm the presence of a layer around the carbon particles, exhibiting a layer thickness ranging from 3 to 26 nm.
From an electrochemical point of view, carbon backbones with a large enveloping surface area
will lead to high mass uptakes in the electroless deposition process and therefore lead to high
capacitance of the electrode. However, for future application, electrodeposition approaches should be investigated in detail, since no deposits will form on the interface between carbon backbone and current collector, leading to a better dynamic performance of the hybrid electrode. Furthermore, the ASAXS-method should be promoted and applied on other material systems, since this technique allows to draw important conclusions and allows to deduce integral and quantitative information towards a rational design of high performance electrodes.
Time and Spatially Resolved Photoluminescence Spectroscopy of Hot Excitons in Gallium Arsenide
(2015)
The present thesis investigates the impact of hot exciton effects on the low-temperature time and spatially resolved photoluminescence (PL) response of free excitons in high-purity gallium arsenide (GaAs). The work at hand extends available studies of hot carrier effects, which in bulk GaAs have up to now focused on hot electron populations. In crucial distinction from previous work, we extensively study the free exciton second LO-phonon replica. The benefit of this approach is twofold. First, the two LO phonon-assisted radiative recombination allows to circumvent the inherent interpretation ambiguities of the previously investigated free exciton zero-phonon line. Second, the recombination line shape of the second LO-phonon replica provides direct experimental access to the exciton temperature, thereby enabling the quantitative assessment of hot exciton effects.
In the first part of the thesis, we address the influence of transient cooling on the time evolution of an initially hot photocarrier ensemble. To this end, we investigate time-resolved photoluminescence (TRPL) signals detected on the free exciton second LO-phonon replica. Settling a long-standing question, we show by comparison with TRPL transients of the free exciton zero-phonon line that the slow free exciton photoluminescence rise following pulsed optical excitation is dominated by the slow buildup of a free exciton population and not by the relaxation of large K-vector excitons to the Brillouin zone center. To establish a quantitative picture of the delayed photoluminescence onset, we determine the cooling dynamics of the initially hot photocarrier cloud from a time-resolved line shape analysis of the second LO-phonon replica. We demonstrate that the Saha equation, which fundamentally describes the thermodynamic population balance between free excitons and the uncorrelated electron-hole plasma, directly translates the experimentally derived cooling curves into the time-dependent conversion of unbound electron-hole pairs into free excitons.
In the second part of the thesis, we establish the impact of hot exciton effects on low-temperature spatially resolved photoluminescence (SRPL) studies. Such experiments are widely used to investigate charge carrier and free exciton diffusion in semiconductors and semiconductor nanostructures. By SRPL spectroscopy of the second LO-phonon replica, we show that above-band gap focused laser excitation inevitably causes local heating in the carrier system, which crucially affects the diffusive expansion of a locally excited exciton packet. Undistorted free exciton diffusion profiles, which are correctly described by the commonly used formulation of the photocarrier diffusion equation, are only observed in the absence of spatial temperature gradients. At low sample temperatures, the reliable determination of free exciton diffusion coefficients from both continuous-wave and time-resolved SRPL spectroscopy requires strictly resonant optical excitation.
Using resonant laser excitation, we observe the dimensional crossover of free exciton diffusion in etched wire structures of a thin, effectively two-dimensional GaAs epilayer. When the lateral wire width falls below the diffusion length, the sample geometry becomes effectively one-dimensional. The exciton diffusion profile along the wire stripe is then consistently reproduced by the steady-state solution to the one-dimensional diffusion equation.
Finally, we demonstrate the formation of macroscopic free and bound exciton photoluminescence rings in bulk GaAs around a focused laser excitation spot. Both ring formation effects are due to pump-induced local heating in the exciton system. For a quantitative assessment of the mechanism underlying the free exciton ring formation, we directly determine the exciton temperature gradient from a spatially resolved line shape analysis of the free exciton second LO-phonon replica. We demonstrate that a pump-induced hot spot locally modifies the thermodynamic population balance between free excitons and unbound electron-hole pairs described by the Saha equation, which naturally explains the emergence of macroscopic free exciton ring structures.
In summary, we demonstrate that quantitative consideration of hot exciton effects provides a coherent picture both of the time-domain free exciton luminescence kinetics and of the distinct spatially resolved photoluminescence patterns developing under the influence of spatial photocarrier diffusion.
Die bSSFP-Sequenz kombiniert kurze Akquisitionszeiten mit einem hohen Signal-zu-Rausch-Verhältnis, was sie zu einer vielversprechenden Bildgebungsmethode macht. Im klinischen Alltag ist diese Technik jedoch bisher - abgesehen von vereinzelten Anwendungen - kaum etabliert. Die Hauptgründe hierfür sind Signalauslöschungen in Form von Bandingartefakten sowie der erzielte T2/T1-gewichtete Mischkontrast. Das Ziel dieser Dissertation war die Entwicklung von Methoden zur Lösung der beiden genannten Limitationen, um so eine umfassendere Verwendung von bSSFP für die MR-Diagnostik zu ermöglichen.
Magnetfeldinhomogenitäten, die im Wesentlichen durch Suszeptibilitätsunterschiede oder Imperfektionen seitens der Scannerhardware hervorgerufen werden, äußern sich bei der bSSFP-Bildgebung in Form von Bandingartefakten. Mit DYPR-SSFP (DYnamically Phase-cycled Radial bSSFP) wurde ein Verfahren vorgestellt, um diese Signalauslöschungen effizient zu entfernen. Während für bereits existierende Methoden mehrere separate bSSFP-Bilder akquiriert und anschließend kombiniert werden müssen, ist für die Bandingentfernung mittels DYPR-SSFP lediglich die Aufnahme eines einzelnen Bildes notwendig. Dies wird durch die neuartige Kombination eines dynamischen Phasenzyklus mit einer radialen Trajektorie mit quasizufälligem Abtastschema ermöglicht. Die notwendigen Bestandteile können mit geringem Aufwand implementiert werden. Des Weiteren ist kein spezielles Rekonstruktionsschema notwendig, was die breite Anwendbarkeit des entwickelten Ansatzes ermöglicht. Konventionelle Methoden zur Entfernung von Bandingartefakten werden sowohl bezüglich ihrer Robustheit als auch bezüglich der notwendigen Messzeit übertroffen.
Um die Anwendbarkeit von DYPR-SSFP auch jenseits der gewöhnlichen Bildgebung zu demonstrieren, wurde die Methode mit der Fett-Wasser-Separation kombiniert. Basierend auf der Dixon-Technik konnten so hochaufgelöste Fett- sowie Wasserbilder erzeugt werden. Aufgrund der Bewegungsinsensitivät der zugrunde liegenden radialen Trajektorie konnten die Messungen unter freier Atmung durchgeführt werden, ohne dass nennenswerte Beeinträchtigungen der Bildqualität auftraten. Die erzielten Ergebnisse am Abdomen zeigten weder Fehlzuordnungen von Fett- und Wasserpixeln noch verbleibende Bandingartefakte.
Ein Nachteil der gewöhnlichen Dixon-basierten Fett-Wasser-Separation ist es, dass mehrere separate Bilder zu verschiedenen Echozeiten benötigt werden. Dies führt zu einer entsprechenden Verlängerung der zugehörigen Messzeit. Abhilfe schafft hier die Verwendung einer Multiecho-Sequenz. Wie gezeigt werden konnte, ermöglicht eine derartige Kombination die robuste, bandingfreie Fett-Wasser-Separation in klinisch akzeptablen Messzeiten.
DYPR-SSFP erlaubt die Entfernung von Bandingartefakten selbst bei starken Magnetfeldinhomogenitäten. Dennoch ist es möglich, dass Signalauslöschungen aufgrund des Effekts der Intravoxeldephasierung verbleiben. Dieses Problem tritt primär bei der Bildgebung von Implantaten oder am Ultrahochfeld auf. Als Abhilfe hierfür wurde die Kombination von DYPR-SSFP mit der sogenannten z-Shim-Technik untersucht, was die Entfernung dieser Artefakte auf Kosten einer erhöhten Messzeit ermöglichte.
Die mit DYPR-SSFP akquirierten radialen Projektionen weisen aufgrund des angewendeten dynamischen Phasenzyklus leicht verschiedene Signallevel und Phasen auf. Diese Tatsache zeigt sich durch inkohärente Bildartefakte, die sich jedoch durch eine Erhöhung der Projektionsanzahl effektiv reduzieren lassen. Folglich bietet es sich in diesem Kontext an, Anwendungen zu wählen, bei denen bereits intrinsisch eine verhältnismäßig hohe Anzahl von Projektionen benötigt wird. Hierbei hat sich gezeigt, dass neben der hochaufgelösten Bildgebung die Wahl einer 3D radialen Trajektorie eine aussichtsreiche Kombination darstellt. Die in der vorliegenden Arbeit vorgestellte 3D DYPR-SSFP-Technik erlaubte so die isotrope bandingfreie bSSFP-Bildgebung, wobei die Messzeit im Vergleich zu einer gewöhnlichen bSSFP-Akquisition konstant gehalten werden konnte. Verbleibende, durch den dynamischen Phasenzyklus hervorgerufene Artefakte konnten effektiv mit einem Rauschunterdrückungsalgorithmus reduziert werden. Anhand Probandenmessungen wurde gezeigt, dass 3D DYPR-SSFP einen aussichtsreichen Kandidaten für die Bildgebung von Hirnnerven sowie des Bewegungsapparats darstellt.
Während die DYPR-SSFP-Methode sowie die darauf beruhenden Weiterentwicklungen effiziente Lösungen für das Problem der Bandingartefakte bei der bSSFP-Bildgebung darstellen, adressiert die vorgestellte RA-TOSSI-Technik (RAdial T-One sensitive and insensitive Steady-State Imaging) das Problem des bSSFP-Mischkontrasts. Die Möglichkeit der Generierung von T2-Kontrasten basierend auf der bSSFP-Sequenz konnte bereits in vorausgehenden Arbeiten gezeigt werden. Hierbei wurde die Tatsache ausgenutzt, dass der T1-Anteil des Signalverlaufs nach Beginn einer bSSFP-Akquisition durch das Einfügen von Inversionspulsen in ungleichmäßigen Abständen aufgehoben werden kann. Ein so akquiriertes Bild weist folglich einen reinen, klinisch relevanten T2-Kontrast auf. Die im Rahmen dieser Arbeit vorgestellte Methode basiert auf dem gleichen Prinzip, jedoch wurde anstelle einer gewöhnlichen kartesischen Trajektorie eine radiale Trajektorie in Kombination mit einer KWIC-Filter-Rekonstruktion verwendet. Somit können bei gleichbleibender oder sogar verbesserter Bildqualität aus einem einzelnen, mit RA-TOSSI akquirierten Datensatz verschiedene T2-Wichtungen als auch gewöhnliche T2/T1-Wichtungen generiert werden. Mittels Variation der Anzahl der eingefügten Inversionspulse konnte ferner gezeigt werden, dass es neben den besagten Wichtungen möglich ist, zusätzliche Kontraste zu generieren, bei denen verschiedene Substanzen im Bild ausgelöscht sind. Diese Substanzen können am Beispiel der Gehirnbildgebung Fett, graue Masse, weiße Masse oder CSF umfassen und zeichnen sich neben den reinen T2-Kontrasten durch eine ähnlich hohe klinische Relevanz aus. Die mögliche Bedeutung der vorgestellten Methode für die klinische Verwendung wurde durch Messungen an einer Gehirntumorpatientin demonstriert.
Zusammenfassend lässt sich sagen, dass die im Rahmen dieser Dissertation entwickelten Techniken einen wertvollen Beitrag zur Lösung der eingangs beschriebenen Probleme der bSSFP-Bildgebung darstellen. Mit DYPR-SSFP akquirierte Bilder sind bereits mit bestehender, kommerzieller Rekonstruktionssoftware direkt am Scanner rekonstruierbar. Die Software für die Rekonstruktion von RA-TOSSI-Datensätzen wurde für Siemens Scanner implementiert. Folglich sind beide Methoden für klinische Studien einsetzbar, was gleichzeitig den Ausblick dieser Arbeit darstellt.