Abstract
Purpose: To compare ab interno trabeculectomy by trabecular meshwork excision to plasma-mediated ablation in primary open-angle glaucoma.
Methods: Retrospectively collected data of TrabEx+ (n=56) and Trabectome (n=99) were compared by coarsened exact matching to reduce confounding and matched based on baseline intraocular pressure and age. Primary outcomes were intraocular pressure and the number of glaucoma medications. Complications and the need for additional glaucoma surgery were assessed. Patients were followed for up to one year.
Results: 53 TrabEx+ could be matched to Trabectome. Baseline intraocular pressure was 16.5 ± 4.6 mmHg in both; age was 73.7 ± 8.8 years and 71.5 ± 9.9 years in TrabEx+ and Trabectome, respectively. TrabEx+ were taking more medications than Trabectome (p<0.001). Intraocular pressure was reduced to 14.8±4.3 in TrabEx+ and 13.4±3.4 in Trabectome at 6 months, and to 14.9±6.0 (p=0.13) in TrabEx+ and to 14.1±3.8 mmHg (all p<0.05) in Trabectome at 12 months. Medications were reduced at both 6 and 12 months (p< 0.05). No differences were seen between both groups at 6 and 12 months. In TrabEx+, only one serious complication occurred, and two patients required further glaucoma surgery.
Conclusion: Although both groups had a baseline intraocular pressure considered low for ab interno trabeculectomy, intraocular pressure and medications were reduced further at 6 and 12 months. Intraocular pressure reduction did not reach significance in TrabEx+ at 12 months. The inter-group comparison did not reveal any significant differences. Both had a low complication rate.
We investigated whether trabeculopuncture (TP) could detect distal outflow resistance to predict the outcome of canal-based glaucoma surgery such as ab interno trabeculectomy (AIT). These procedures have a high utilization in open angle glaucoma, but fail in eyes with an unidentified distal outflow resistance. We assigned 81 porcine eyes to two groups: trial (n = 42) and control (n = 39). At 24 h, four YAG-laser trabeculopunctures were placed nasally, followed by a 180° AIT at the same site at 48 h. The proportion of TP responders between both AIT groups was compared. Histology and outflow canalograms were determined. Both post-TP and post-AIT IOPs were lower than baseline IOP (p = 0.015 and p < 0.01, respectively). The success rates of TP and AIT were 69% and 85.7%, respectively. Sensitivity and specificity values of TP as predictive test for AIT success were 77.7% and 83.3%, respectively. The positive and negative predictive values were 96.6% and 38.5%, respectively. We conclude that a 10% reduction in IOP after TP can be used as a predictor for the success (> 20% IOP decrease) of 180° AIT in porcine eyes.