Refine
Has Fulltext
- yes (90)
Is part of the Bibliography
- yes (90)
Year of publication
Document Type
- Journal article (77)
- Conference Proceeding (7)
- Preprint (6)
Language
- English (90) (remove)
Keywords
- PET (27)
- Positronen-Emissions-Tomografie (19)
- positron emission tomography (15)
- theranostics (12)
- CXCR4 (10)
- PET/CT (9)
- PRRT (9)
- molecular imaging (9)
- multiple myeloma (9)
- neuroendocrine tumor (8)
- prostate cancer (7)
- PSMA (6)
- SPECT (6)
- SSTR (6)
- RADS (5)
- somatostatin receptor (5)
- 18F-FDG (4)
- 18F-DCFPyL (3)
- 18F-LMI1195 (3)
- DaTscan (3)
- FDG (3)
- NET (3)
- Prostate Cancer (3)
- ageing (3)
- chemokine receptor (3)
- fibroblast activation protein (3)
- medicine (3)
- norepinephrine transporter (3)
- peptide receptor radionuclide therapy (3)
- prostate-specific membrane antigen (3)
- radioligand therapy (3)
- sympathetic nervous system (3)
- vandetanib (3)
- 11C-HED (2)
- 18F-FDG PET/CT (2)
- 18F-FDS (2)
- DOTATOC (2)
- Ioflupane (2)
- MAG3 (2)
- MIBG (2)
- Neuroendocrine Tumor (2)
- PSMA-PET (2)
- PSMA-RADS (2)
- Parkinson (2)
- Parkinson Disease (2)
- Parkinson-Krankheit (2)
- Pentixafor (2)
- Positron Emission Tomography (2)
- Positron emission tomography (2)
- SSTR-RADS (2)
- Stammzelle (2)
- TKI (2)
- Virchow Node (2)
- [177Lu]-DOTATATE/-DOTATOC (2)
- [68Ga] (2)
- antidepressant (2)
- bone disease (2)
- cardiomyocytes (2)
- diabetes (2)
- fatty acid (2)
- glioblastoma multiforme (2)
- head and neck cancer (2)
- heart failure (2)
- hiPSC-CM (2)
- induced pluripotent stem cells (2)
- kidney (2)
- medullary thyroid carcinoma (2)
- molecular medicine (2)
- myocardial sympathetic innervation imaging (2)
- personalized medicine (2)
- personalized treatment (2)
- precision medicine (2)
- prostate-specific membrane antigen (PSMA) (2)
- radionuclide therapy (2)
- relapse (2)
- reporting and data system (2)
- sarcoidosis (2)
- solid tumors (2)
- spleen (2)
- stem cell therapy (2)
- survival (2)
- tracer (2)
- tumor heterogeneity (2)
- tyrosine kinase inhibitor (2)
- 11C-Hydroxyephedrine (1)
- 11C-Methionine PET/CT (1)
- 11C-hydroxyephedrine (1)
- 123I-Ioflupane (1)
- 123I-mIBG (1)
- 123I-metaiodobenzylguanidine (1)
- 177Lu (1)
- 177Lu-DOTATATE (1)
- 177Lu-DOTATOC (1)
- 18F-DCFPL (1)
- 18F-flurpiridaz (1)
- 18FFBnTP (1)
- 2- deoxy-2-(18F)fluoro-D-glucose (1)
- 2-deoxy-2-(18F)fluoro-D-glucose (1)
- 2-deoxy-2-18F-fluoro-D-sorbitol (1)
- 53BP1 (1)
- 68Ga-DOTANOC (1)
- 68Ga-DOTATATE (1)
- 68Ga-DOTATATE/-TOC (1)
- 68Ga-DOTATOC (1)
- 68Ga-PSMA ligand PET/CT (1)
- 68Ga-Pentixafor PET/CT (1)
- 99mTc-DTPA (1)
- <sup>18</sup>F-FDG (1)
- <sup>68</sup>Ga-Pentixafor (1)
- Antibodies (1)
- Antidepressants (1)
- Arginine (1)
- BRAF mutation (1)
- C-11-methionine pet (1)
- C-X-C motif chemokine receptor 4 (1)
- CD38 (1)
- CXCR4/SDF-1 (1)
- Capicua transcriptional repressor (1)
- Cardiovascular diseases (1)
- DNA double-strand breaks (1)
- DOTA-EB-TATE (1)
- Drug resistance (1)
- ECG (1)
- Extramedullary disease (1)
- F-18-FDG PET (1)
- FDG PET/CT (1)
- GI (1)
- Ga-68 (1)
- Ganglia (1)
- Gastrointestinal (1)
- Glomerular filtration (1)
- HFmrEF (1)
- HMDP hydroxymethylene diphosphonate (1)
- Heart failure (1)
- Herz (1)
- Hyperkalaemia (1)
- Imaging pitfalls (1)
- Lysine (1)
- MDD (1)
- MI-RADS (1)
- MIBG scintigraphy (1)
- MOR202 (1)
- MPI (1)
- MRI (1)
- Medullärer Schilddrüsenkrebs (1)
- Merkel cell carcinoma (1)
- Metaiodobenzylguanidine (1)
- Molecular imaging (1)
- Multiple myeloma (1)
- Myeloma cells (1)
- Myelomas (1)
- Myocardial-perfusion SPECT (1)
- Myokarditis (1)
- NEC (1)
- Neuroendocrine (1)
- Nierenfunktionsstörung (1)
- Oncology (1)
- PROMISE (1)
- PSMA-RADS-3A (1)
- PSMA-RADS-3B (1)
- PSMA-targeted PET (1)
- Pancreas (1)
- Parkinson's disease (1)
- Parkinsonism (1)
- Parkinson’s disease (1)
- Pitfall (1)
- Positron-Emission Tomography (1)
- Positronenemissionstomografie (1)
- Prostata (1)
- Radiofluorine (1)
- Radionuclide Therapy (1)
- Radiotracer (1)
- SPECT Scanner (1)
- SPECT/CT (1)
- SSTR-PET (1)
- SUV (1)
- Single-Photon-Emissions-Computertomographie (1)
- Sodium-Glucose Cotransporters (SGLTs) (1)
- Somatostatin receptor expression (1)
- Standardisierung (1)
- T-shaped π-π stacking (1)
- T-shaped π–π stacking (1)
- Tracer (1)
- ZDF rats (1)
- [177Lu]/[90Y]PentixaTher (1)
- [68Ga]DOTATOC (1)
- [68Ga]PentixaFor (1)
- [68Ga]Pentixafor (1)
- [\(^{68}\)Ga] pentixafor (1)
- [\(^{68}\)Ga]Ga-FAPI (1)
- [\(^{68}\)Ga]Pentixafor (1)
- \(^{11}\)C-Methionine-PET (1)
- \(^{11}\)C-methionine (1)
- \(^{18}\)F (1)
- \(^{18}\)F-FDG (1)
- \(^{18}\)F-FDG PET/CT (1)
- \(^{18}\)F-fluorodeoxyglucose (1)
- \(^{68}\)Ga (1)
- \(^{68}\)Ga-Pentixafor (1)
- accuracy (1)
- agreement (1)
- amino acids (1)
- androgen deprivation therapy (1)
- angiogenesis (1)
- antidepressants (1)
- autologous transplantation (1)
- autonomic nervous system (1)
- benzylguanidine (1)
- biokinetics (1)
- biomarker (1)
- biomarkers (1)
- biosynthesis (1)
- bone marrow cells (1)
- brain (1)
- brain tumors (1)
- cancer (1)
- cardiac (1)
- cardiac innervation imaging (1)
- cardiac neurohormonal system (1)
- cardiac sympathetic nerve system (1)
- cardiac sympathetic nervous system (1)
- cell staining (1)
- cells (1)
- cerebral gliomas (1)
- chemokine receptor-4 (1)
- clinical diagnosis (1)
- clinical studies (1)
- collimator (1)
- comparability (1)
- contrast agent (1)
- coronary artery disease (1)
- criteria (1)
- daratumumab (1)
- delineation (1)
- dementia (1)
- depression (1)
- detection rate (1)
- diabetic cardiomyopathy (1)
- diffusion weighted mri (1)
- disease (1)
- dosimetry (1)
- ejection fraction (1)
- endocrinology (1)
- endoradiotherapy (1)
- esophagogastric junction (1)
- evans blue (1)
- experience (1)
- extramedullary hematopoiesis (1)
- glioblastoma (1)
- glioma (1)
- glomerular filtration rate (1)
- guidelines (1)
- heart (1)
- heart failure with mid-range ejection fraction (1)
- heart-to-mediastinum ratio (1)
- high risk (1)
- hydroxyephedrine (1)
- hyperkalemia (1)
- imaging (1)
- imaging techniques (1)
- immune infiltration (1)
- immunostaining (1)
- improves (1)
- in vivo imaging (1)
- inflammation (1)
- interobserver (1)
- interreader (1)
- intraindividual comparison (1)
- involvement (1)
- kidney function (1)
- left-ventricular function (1)
- lesions (1)
- linear conversion (1)
- mIBG (1)
- mRNA (1)
- machine learning (1)
- macrophages (1)
- magnetic resonance imaging (1)
- major depressive disorder (1)
- malignancies (1)
- management (1)
- medium-sized animals (1)
- metabolic tumor volume (MTV) (1)
- metabolic tumour volume (MTV) (1)
- methionine (1)
- methionine pet (1)
- miRNA (1)
- microenvironment (1)
- microglial cells (1)
- mouse (1)
- moycardial sympathetic innervation (1)
- multiple system atrophy (1)
- myocardial perfusion imaging (1)
- myocarditis (1)
- nephrology (1)
- neuroendocrine neoplasia (1)
- nonhuman primates (1)
- nuclear cardiology (1)
- nuclear medicine (1)
- ollimator (1)
- organic cation transporter (1)
- pancreas (1)
- pattern (1)
- peptide receptor (1)
- performance (1)
- peripheral nervous system (1)
- phaeochromocytoma (1)
- phenethylguanidine (1)
- pleural mesothelioma (1)
- positron emission tomography/computed tomography (1)
- positron-emission-tomography (1)
- post-reconstruction filtering (1)
- progression (1)
- quality (1)
- quantification (1)
- radiogenomics (1)
- radiotherapy (1)
- radiotracer (1)
- radiotracer kinetics (1)
- rats (1)
- recurrent prostate cancer (1)
- refractory (1)
- renal (1)
- renal failure (1)
- renal function (1)
- renal imaging (1)
- renal scintigraphy (1)
- reporting and data systems (1)
- retrospective studies (1)
- risk (1)
- scanner (1)
- single photon emission computed tomography: sympathetic nerve (1)
- skeletal (1)
- skin biopsy (1)
- small animal SPECT (1)
- small-animal imaging (1)
- smoldering myeloma (1)
- software (1)
- somatostatin (1)
- somatostatin receptor (SSTR) (1)
- somatostatin receptors (1)
- split renal function (1)
- standardization (1)
- standardized reporting (1)
- stem cells (1)
- stem-cell research (1)
- stem-cell transplantation (1)
- stimulation (1)
- storage vesicle turnover (1)
- structure–activity relationships (1)
- sympathetic nerve (1)
- total lesion PSMA (1)
- total lesion glycolysis (TLG) (1)
- total lesion methionine uptake (TLMU) (1)
- transcriptome (1)
- treatment response (1)
- tumor burden (1)
- tumor microenvironment (1)
- unilateral ureteral obstruction (1)
- uptake (1)
- urology (1)
- vestibular schwannoma (1)
- γ-H2AX (1)
Institute
- Klinik und Poliklinik für Nuklearmedizin (90) (remove)
Sonstige beteiligte Institutionen
- Johns Hopkins School of Medicine (15)
- Johns Hopkins University School of Medicine (5)
- Johns Hopkins School of Medicine, Baltimore, MD, U.S. (3)
- Department of Biomedical Imaging, National Cerebral and Cardiovascular Research Center, Suita, Japan (2)
- Division of Medical Technology and Science, Department of Medical Physics and Engineering, Course of Health Science, Osaka University Graduate School of Medicine, Suita Japan (2)
- Institut for Molecular Biology and CMBI, Department of Genomics, Stem Cell Biology and Regenerative Medicine, Leopold-Franzens-University Innsbruck, Innsbruck, Austria (2)
- Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Science, Baltimore, MD, USA (2)
- Department of Nuclear Medicine, Kanazawa University (1)
- Hospital Augsburg, Augsburg, Germany (1)
- Johns Hopkins School of Medicine, Baltimore, MD, USA (1)
EU-Project number / Contract (GA) number
- 701983 (34)
Purpose
While [18F]-fluorodeoxyglucose ([18F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT.
Methods
Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [18F]FDG and [68Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUVmax) and peak (SUVpeak) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference.
Results
[18F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([18F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [18F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples.
Conclusion
FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted.
Importance
Squamous cell carcinoma (SCC) of the oral cavity is one of the most common tumor entities worldwide. Precise initial staging is necessary to determine a diagnosis, treatment, and prognosis.
Objective
To examine the diagnostic accuracy of preoperative 18-F fluorodeoxyglucose (FDG) positron emission tomographic/computed tomographic (PET/CT) imaging in detecting cervical lymph node metastases.
Design, Setting, and Participants
This prospective diagnostic study was performed at a single tertiary reference center between June 1, 2013, and January 31, 2016. Data were analyzed from April 7, 2018, through May 31, 2019. Observers of the FDG PET/CT imaging were blinded to patients’ tumor stage. A total of 150 treatment-naive patients with clinical suspicion of SCC of the oral cavity were enrolled.
Exposures
All patients underwent FDG PET/CT imaging before local tumor resection with selective or complete neck dissection.
Main Outcomes and Measures
The accuracy of FDG PET/CT in localizing primary tumor, lymph node, and distant metastases was tested. Histopathologic characteristics of the tissue samples served as the standard of reference.
Results
Of the 150 patients enrolled, 135 patients (74 [54.8%] men) with a median age of 63 years (range, 23-88 years) met the inclusion criteria (histopathologically confirmed primary SCC of the oral cavity/level-based histopathologic assessment of the resected lymph nodes). Thirty-six patients (26.7%) in the study cohort had neck metastases. Use of FDG PET/CT detected cervical lymph node metastasis with 83.3% sensitivity (95% CI, 71.2%-95.5%) and 84.8% specificity (95% CI, 77.8%-91.9%) and had a negative predictive value of 93.3% (95% CI, 88.2%-98.5%). The specificity was higher than for contrast-enhanced cervical CT imaging (67.0%; 95% CI, 57.4%-76.7%; P < .01) and cervical magnetic resonance imaging (62.6%; 95% CI, 52.7%-72.6%; P < .001). Ipsilateral lymph node metastasis in left- or right-sided primary tumor sites was detected with 78.6% sensitivity (95% CI, 63.4%-93.8%) and 83.1% specificity (95% CI, 75.1%-91.2%), and contralateral metastatic involvement was detected with 66.7% sensitivity (95% CI, 28.9%-100.0%) and 98.6% specificity (95% CI, 95.9%-100.0%). No distant metastases were observed.
Conclusions and Relevance
In this study, FDG PET/CT imaging had a high negative predictive value in detecting cervical lymph node metastasis in patients with newly diagnosed, treatment-naive SCC of the oral cavity. Routine clinical use of FDG PET/CT might lead to a substantial reduction of treatment-related morbidity in most patients.
Background
The chemokine receptor CXCR4 is frequently overexpressed and associated with adverse prognosis in most hematopoietic malignancies and solid cancers. Recently, CXCR4 molecular imaging using the CXCR4-specific positron emission tomography (PET) tracer Pentixafor ([68Ga]Pentixafor) has become a well-established method to non-invasively measure CXCR4 expression in vivo. In previous Pentixafor imaging studies, highly variable CXCR4 tracer uptake to the spleen was observed.
Results
We investigated the hypothesis that enhanced spleen [68Ga]Pentixafor uptake and thus CXCR4 expression in patients with solid tumors would indicate an activated spleen state and/or an association with clinical and prognostic features and survival parameters. In this retrospective study, [68Ga]Pentixafor-PET images and patient records of 145 solid tumor patients representing 27 cancer entities were investigated for an association of spleen [68Ga]Pentixafor uptake and clinical characteristics and outcome. Based on this assessment, we did not observe differences in clinical outcomes, measured by progression-free survival, overall survival and remission status neither within the entire cohort nor within subgroups of adrenal cancer, desmoplastic small round cell tumor, neuroendocrine tumors, non-small cell lung cancer, small cell lung cancer and pancreatic adenocarcinoma patients. No tumor entity showed especially high levels of spleen [68Ga]Pentixafor uptake compared to others or a control cohort. However, when investigating laboratory parameters, there was a positive correlation of high spleen [68Ga]Pentixafor uptake with leukocyte and/or platelet counts in neuroendocrine tumors, non-small cell lung cancer and small cell lung cancer.
Conclusion
Spleen [68Ga]Pentixafor uptake was not associated with stage of disease and clinical outcomes in solid tumor patients. We identified positively associated platelet and/or leukocyte counts with spleen [68Ga]Pentixafor uptake in neuroendocrine tumors, non-small cell lung cancer and small cell lung cancer, suggesting that splenic CXCR4 expression could possibly play a role in systemic immunity/inflammation in some types of solid tumors or a subgroup of patients within solid tumor entities.
Purpose
While [\(^{18}\)F]-fluorodeoxyglucose ([\(^{18}\)F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT.
Methods
Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [\(^{18}\)F]FDG and [\(^{68}\)Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUV\(_{max}\)) and peak (SUV\(_{peak}\) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference.
Results
[\(^{18}\)F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([\(^{18}\)F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [\(^{18}\)F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples.
Conclusion
FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted.
Purpose
For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader’s anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader’s confidence, and its implementation in clinical routine.
Procedures
A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader’s confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen’s d was calculated (small, d = 0.20; large effect, d = 0.80).
Results
Of 22 participants, Pre and Post were returned by 21/22 (95.5%). In total, 14/21 (66.7%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d = − 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader’s confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21).
Conclusions
A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results.
Background
The heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible.
Methods
We included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure.
Results
H/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R\(^2\) = 0.99, p < 0.001 and R\(^2\) = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 × H/M-ME + 0.63, R\(^2\) = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 ± 0.04; mean relative absolute error 3.2 ± 2.6%).
Conclusions
The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions.
Background
CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs.
Methods
Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden.
Results
Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found.
Conclusions
In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged.
(1) Background: C-X-C Motif Chemokine Receptor 4 (CXCR4) and Fibroblast Activation Protein Alpha (FAP) are promising theranostic targets. However, it is unclear whether CXCR4 and FAP positivity mark distinct microenvironments, especially in solid tumors. (2) Methods: Using Random Forest (RF) analysis, we searched for entity-independent mRNA and microRNA signatures related to CXCR4 and FAP overexpression in our pan-cancer cohort from The Cancer Genome Atlas (TCGA) database — representing n = 9242 specimens from 29 tumor entities. CXCR4- and FAP-positive samples were assessed via StringDB cluster analysis, EnrichR, Metascape, and Gene Set Enrichment Analysis (GSEA). Findings were validated via correlation analyses in n = 1541 tumor samples. TIMER2.0 analyzed the association of CXCR4 / FAP expression and infiltration levels of immune-related cells. (3) Results: We identified entity-independent CXCR4 and FAP gene signatures representative for the majority of solid cancers. While CXCR4 positivity marked an immune-related microenvironment, FAP overexpression highlighted an angiogenesis-associated niche. TIMER2.0 analysis confirmed characteristic infiltration levels of CD8+ cells for CXCR4-positive tumors and endothelial cells for FAP-positive tumors. (4) Conclusions: CXCR4- and FAP-directed PET imaging could provide a non-invasive decision aid for entity-agnostic treatment of microenvironment in solid malignancies. Moreover, this machine learning workflow can easily be transferred towards other theranostic targets.
Purpose: A new PET radiotracer \(^{18}\)F-AF78 showing great potential for clinical application has been reported recently. It belongs to a new generation of phenethylguanidine-based norepinephrine transporter (NET)-targeting radiotracers. Although many efforts have been made to develop NET inhibitors as antidepressants, systemic investigations of the structure–activity relationships (SARs) of NET-targeting radiotracers have rarely been performed. Methods: Without changing the phenethylguanidine pharmacophore and 3-fluoropropyl moiety that is crucial for easy labeling, six new analogs of \(^{18}\)F-AF78 with different meta-substituents on the benzene-ring were synthesized and evaluated in a competitive cellular uptake assay and in in vivo animal experiments in rats. Computational modeling of these tracers was established to quantitatively rationalize the interaction between the radiotracers and NET. Results: Using non-radiolabeled reference compounds, a competitive cellular uptake assay showed a decrease in NET-transporting affinity from meta-fluorine to iodine (0.42 and 6.51 µM, respectively), with meta-OH being the least active (22.67 µM). Furthermore, in vivo animal studies with radioisotopes showed that heart-to-blood ratios agreed with the cellular experiments, with AF78(F) exhibiting the highest cardiac uptake. This result correlates positively with the electronegativity rather than the atomic radius of the meta-substituent. Computational modeling studies revealed a crucial influence of halogen substituents on the radiotracer–NET interaction, whereby a T-shaped π–π stacking interaction between the benzene-ring of the tracer and the amino acid residues surrounding the NET binding site made major contributions to the different affinities, in accordance with the pharmacological data. Conclusion: The SARs were characterized by in vitro and in vivo evaluation, and computational modeling quantitatively rationalized the interaction between radiotracers and the NET binding site. These findings pave the way for further evaluation in different species and underline the potential of AF78(F) for clinical application, e.g., cardiac innervation imaging or molecular imaging of neuroendocrine tumors.
Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM.
This study aimed to explore the correlation between imaging patterns and clinical features in patients with smoldering multiple myeloma (SMM) who simultaneously underwent 18F-FDG, 11C-Methionine, and 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT). We retrieved and analyzed clinical characteristics and PET imaging data of 10 patients with SMM. We found a significant correlation between bone marrow (BM) plasma cell (PC) infiltration and mean standardized uptake values (SUV\(_{mean}\)) of lumbar vertebrae L2-L4 on 11C-Methionine PET/CT scans (r = 0.676, p = 0.031) and 68Ga-Pentixafor PET/CT scans (r = 0.839, p = 0.002). However, there was no significant correlation between BM involvement and SUV\(_{mean}\) of lumbar vertebrae L2-L4 on 18F-FDG PET/CT scans (r = 0.558, p = 0.093). Similarly, mean target-to-background ratios (TBR\(_{mean}\)) of lumbar vertebrae L2-L4 also correlated with bone marrow plasma cell (BMPC) infiltration in 11C-Methionine PET/CT (r = 0.789, p = 0.007) and 68Ga-Pentixafor PET/CT (r = 0.724, p = 0.018) PET/CT. In contrast, we did not observe a significant correlation between BMPC infiltration rate and TBR\(_{mean}\) in 18F-FDG PET/CT (r = 0.355, p = 0.313). Additionally, on 11C-Methionine PET/CT scans, we found a significant correlation between BMPC infiltration and TBR\(_{max}\) of lumbar vertebrae L2-L4 (r = 0.642, p = 0.045). In conclusion, 11C-Methionine and 68Ga-Pentixafor PET/CT demonstrate higher sensitivity than 18F-FDG PET/CT in detecting BM involvement in SMM.
(1) Background: We aimed to quantitatively investigate [\(^{68}\)Ga]Ga-FAPI-04 uptake in normal organs and to assess a relationship with the extent of FAPI-avid tumor burden. (2) Methods: In this single-center retrospective analysis, thirty-four patients with solid cancers underwent a total of 40 [\(^{68}\)Ga]Ga-FAPI-04 PET/CT scans. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were established by placing volumes of interest (VOIs) in the heart, liver, spleen, pancreas, kidneys, and bone marrow. Total tumor burden was determined by manual segmentation of tumor lesions with increased uptake. For tumor burden, quantitative assessment included maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA = TV × SUV\(_{mean}\)). Associations between uptake in normal organs and tumor burden were investigated by applying Spearman's rank correlation coefficient. (3) Results: Median SUV\(_{mean}\) values were 2.15 in the pancreas (range, 1.05–9.91), 1.42 in the right (range, 0.57–3.06) and 1.41 in the left kidney (range, 0.73–2.97), 1.2 in the heart (range, 0.46–2.59), 0.86 in the spleen (range, 0.55–1.58), 0.65 in the liver (range, 0.31–2.11), and 0.57 in the bone marrow (range, 0.26–0.94). We observed a trend towards significance for uptake in the myocardium and tumor-derived SUV\(_{max}\) (ρ = 0.29, p = 0.07) and TV (ρ = −0.30, p = 0.06). No significant correlation was achieved for any of the other organs: SUV\(_{max}\) (ρ ≤ 0.1, p ≥ 0.42), TV (ρ ≤ 0.11, p ≥ 0.43), and FTA (ρ ≤ 0.14, p ≥ 0.38). In a sub-analysis exclusively investigating patients with high tumor burden, significant correlations of myocardial uptake with tumor SUV\(_{max}\) (ρ = 0.44; p = 0.03) and tumor-derived FTA with liver uptake (ρ = 0.47; p = 0.02) were recorded. (4) Conclusions: In this proof-of-concept study, quantification of [\(^{68}\)Ga]Ga-FAPI-04 PET showed no significant correlation between normal organs and tumor burden, except for a trend in the myocardium. Those preliminary findings may trigger future studies to determine possible implications for treatment with radioactive FAP-targeted drugs, as higher tumor load or uptake may not lead to decreased doses in the majority of normal organs.
Background. Equipped with two stationary detectors, a large bore collimator for medium-sized animals has been recently introduced for dedicated preclinical single-photon emission computed tomography (SPECT) imaging. We aimed to evaluate the basic performance of the system using phantoms and healthy rabbits. Methods. A general-purpose medium-sized animal (GP-MSA) collimator with 135 mm bore diameter and thirty-three holes of 2.5 mm diameter was installed on an ultrahigh-resolution scanner equipped with two large stationary detectors (U-SPECT5-E/CT). The sensitivity and uniformity were investigated using a point source and a cylinder phantom containing 99mTc-pertechnetate, respectively. Uniformity (in %) was derived using volumes of interest (VOIs) on images of the cylinder phantom and calculated as , with lower values of % indicating superior performance. The spatial resolution and contrast-to-noise ratios (CNRs) were evaluated with images of a hot-rod Derenzo phantom using different activity concentrations. Feasibility of in vivo SPECT imaging was finally confirmed by rabbit imaging with the most commonly used clinical myocardial perfusion SPECT agent [99mTc]Tc-sestamibi (dynamic acquisition with a scan time of 5 min). Results. In the performance evaluation, a sensitivity of 790 cps/MBq, a spatial resolution with the hot-rod phantom of 2.5 mm, and a uniformity of 39.2% were achieved. The CNRs of the rod size 2.5 mm were 1.37, 1.24, 1.20, and 0.85 for activity concentration of 29.2, 1.0, 0.5, and 0.1 MBq/mL, respectively. Dynamic SPECT imaging in rabbits allowed to visualize most of the thorax and to generate time-activity curves of the left myocardial wall and ventricular cavity. Conclusion. Preclinical U-SPECT5-E/CT equipped with a large bore collimator demonstrated adequate sensitivity and resolution for in vivo rabbit imaging. Along with its unique features of SPECT molecular functional imaging is a superior collimator technology that is applicable to medium-sized animal models and thus may promote translational research for diagnostic purposes and development of novel therapeutics.
Background. Mediating glucose absorption in the small intestine and renal clearance, sodium glucose cotransporters (SGLTs) have emerged as an attractive therapeutic target in diabetic patients. A substantial fraction of patients, however, only achieve inadequate glycemic control. Thus, we aimed to assess the potential of the SGLT-targeting PET radiotracer alpha-methyl-4-deoxy-4-[\(^{18}\)F]fluoro-D-glucopyranoside ([\(^{18}\)F]Me4FDG) as a noninvasive intestinal and renal biomarker of SGLT-mediated glucose transport. Methods. We investigated healthy rats using a dedicated small animal PET system. Dynamic imaging was conducted after administration of the reference radiotracer 2-deoxy-2-[\(^{18}\)F]fluoro-D-glucose ([\(^{18}\)F]FDG), or the SGLT-targeting agent, [\(^{18}\)F]Me4FDG either directly into the digestive tract (for assessing intestinal absorption) or via the tail vein (for evaluating kidney excretion). To confirm the specificity of [18F]Me4FDG and responsiveness to treatment, a subset of animals was also pretreated with the SGLT inhibitor phlorizin. In this regard, an intraintestinal route of administration was used to assess tracer absorption in the digestive tract, while for renal assessment, phlorizin was injected intravenously (IV). Results. Serving as reference, intestinal administration of [\(^{18}\)F]FDG led to slow absorption with retention of % of administered radioactivity at 15 min. [\(^{18}\)F]Me4FDG, however, was rapidly absorbed into the blood and cleared from the intestine within 15 min, leading to markedly lower tracer retention of % (). Intraintestinal phlorizin led to marked increase of [\(^{18}\)F]Me4FDG uptake (15 min, %; vs. untreated controls), supporting the notion that this PET agent can measure adequate SGLT inhibition in the digestive tract. In the kidneys, radiotracer was also sensitive to SGLT inhibition. After IV injection, [\(^{18}\)F]Me4FDG reabsorption in the renal cortex was significantly suppressed by phlorizin when compared to untreated animals (%ID/g at 60 min, vs. untreated controls, ; ). Conclusion. As a noninvasive read-out of the concurrent SGLT expression in both the digestive tract and the renal cortex, [\(^{18}\)F]Me4FDG PET may serve as a surrogate marker for treatment response to SGLT inhibition. As such, [\(^{18}\)F]Me4FDG may enable improvement in glycemic control in diabetes by PET-based monitoring strategies.
Background: Radiolabeled agents that are substrates for the norepinephrine transporter (NET) can be used to quantify cardiac sympathetic nervous conditions and have been demonstrated to identify high-risk congestive heart failure (HF) patients prone to arrhythmic events. We aimed to fully characterize the kinetic profile of the novel \(^{18}\)F-labeled NET probe AF78 for PET imaging of the cardiac sympathetic nervous system (SNS) among various species.
Methods: \(^{18}\)F-AF78 was compared to norepinephrine (NE) and established SNS radiotracers by employing in vitro cell assays, followed by an in vivo PET imaging approach with healthy rats, rabbits and nonhuman primates (NHPs). Additionally, chase protocols were performed in NHPs with NET inhibitor desipramine (DMI) and the NE releasing stimulator tyramine (TYR) to investigate retention kinetics in cardiac SNS.
Results: Relative to other SNS radiotracers, 18F-AF78 showed higher transport affinity via NET in a cell-based competitive uptake assay (IC\(^{50}\) 0.42 ± 0.14 µM), almost identical to that of NE (IC\(^{50}\), 0.50 ± 0.16 µM, n.s.). In rabbits and NHPs, initial cardiac uptake was significantly reduced by NET inhibition. Furthermore, cardiac tracer retention was not affected by a DMI chase protocol but was markedly reduced by intermittent TYR chase, thereby suggesting that \(^{18}\)F-AF78 is stored and can be released via the synaptic vesicular turnover process. Computational modeling hypothesized the formation of a T-shaped π-π stacking at the binding site, suggesting a rationale for the high affinity of \(^{18}\)F-AF78.
Conclusion: \(^{18}\)F-AF78 demonstrated high in vitro NET affinity and advantageous in vivo radiotracer kinetics across various species, indicating that \(^{18}\)F-AF78 is an SNS imaging agent with strong potential to guide specific interventions in cardiovascular medicine.
Purpose
The radiolabelled somatostatin analogue [\(^{177}\)Lu]Lu-DOTA-EB-TATE binds to albumin via Evans blue, thereby increasing the residence time in the blood and potentially allowing more therapeutic agent to be absorbed into the target tissue during peptide receptor radionuclide therapy. It was tested in selected patients whether the substance is superior to [\(^{177}\)Lu]Lu-DOTA-TOC.
Methods
Activity kinetics in organs and tumours after [\(^{177}\)Lu]Lu-DOTA-EB-TATE and [\(^{177}\)Lu]Lu-DOTA-TOC were compared intraindividually in five patients with progressive somatostatin receptor-positive disease scheduled for radionuclide therapy.
Resuluts
In comparison to [\(^{177}\)Lu]Lu-DOTA-TOC, tumour doses per administered activity were higher for [\(^{177}\)Lu]Lu-DOTA-EB-TATE in 4 of 5 patients (median ratio: 1.7; range: 0.9 to 3.9), kidney doses (median ratio: 3.2; range: 1.6 to 9.8) as well as spleen doses (median ratio: 4.7; range 1.2 to 6.2) in all patients, and liver doses in 3 of 4 evaluable patients (median ratio: 4.0; range: 0.7 to 4.9). The tumour to critical organs absorbed dose ratios were higher after [\(^{177}\)Lu]Lu-DOTA-TOC in 4 of 5 patients.
Conclusions
Prior to a treatment with [\(^{177}\)Lu]Lu-DOTA-EB-TATE, it should be assessed individually whether the compound is superior to established substances.
\(^{11}\)C-methionine (\(^{11}\)C-MET) is a new positron emission tomography (PET) tracer for the assessment of disease activity in multiple myeloma (MM) patients, with preliminary data suggesting higher sensitivity and specificity than \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG). However, the value of tumor burden biomarkers has yet to be investigated. Our goals were to corroborate the superiority of \(^{11}\)C-MET for MM staging and to compare its suitability for the assessment of metabolic tumor burden biomarkers in comparison to \(^{18}\)F-FDG. Twenty-two patients with newly diagnosed, treatment-naïve symptomatic MM who had undergone \(^{11}\)C-MET and \(^{18}\)F-FDG PET/CT were evaluated. Standardized uptake values (SUV) were determined and compared with total metabolic tumor volume (TMTV) for both tracers: total lesion glycolysis (TLG) and total lesion \(^{11}\)C-MET uptake (TLMU). PET-derived values were compared to Revised International Staging System (R-ISS), cytogenetic, and serologic MM markers such as M component, beta 2 microglobulin (B2M), serum free light chains (FLC), albumin, and lactate dehydrogenase (LDH). In 11 patients (50%), \(^{11}\)C-MET detected more focal lesions (FL) than FDG (p < 0.01). SUVmax, SUVmean, SUVpeak, TMTV, and TLMU were also significantly higher in \(^{11}\)C-MET than in \(^{18}\)F-FDG (p < 0.05, respectively). \(^{11}\)C-MET PET biomarkers had a better correlation with tumor burden (bone marrow plasma cell infiltration, M component; p < 0.05 versus p = n.s. respectively). This pilot study suggests that \(^{11}\)C-MET PET/CT is a more sensitive marker for the assessment of myeloma tumor burden than \(^{18}\)F-FDG. Its implications for prognosis evaluation need further investigation.
Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated \(^{18}\)F-fluorodeoxyglucose (\(^{18}\)F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. \(^{18}\)F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 & PLUSMN; 57.7 mu l*, 380.8 & PLUSMN; 57.2 mu l*, 398.0 & PLUSMN; 63.1 mu l*, and 444.8 & PLUSMN; 75.3 mu l at 4, 8, 12, and 16 frames, respectively; *P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed (P < 0.005), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used.
Stem cell therapy holds great promise for tissue regeneration and cancer treatment, although its efficacy is still inconclusive and requires further understanding and optimization of the procedures. Non-invasive cell tracking can provide an important opportunity to monitor in vivo cell distribution in living subjects. Here, using a combination of positron emission tomography (PET) and in vitro 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) direct cell labelling, the feasibility of engrafted stem cell monitoring was tested in multiple animal species. Human mesenchymal stem cells (MSCs) were incubated with phosphate-buffered saline containing [18F]FDG for in vitro cell radiolabelling. The pre-labelled MSCs were administrated via peripheral vein in a mouse (n=1), rats (n=4), rabbits (n=4) and non-human primates (n=3), via carotid artery in rats (n=4) and non-human primates (n=3), and via intra-myocardial injection in rats (n=5). PET imaging was started 10 min after cell administration using a dedicated small animal PET system for a mouse and rats. A clinical PET system was used for the imaging of rabbits and non-human primates. After MSC administration via peripheral vein, PET imaging revealed intense radiotracer signal from the lung in all tested animal species including mouse, rat, rabbit, and non-human primate, suggesting administrated MSCs were trapped in the lung tissue. Furthermore, the distribution of the PET signal significantly differed based on the route of cell administration. Administration via carotid artery showed the highest activity in the head, and intra-myocardial injection increased signal from the heart. In vitro [18F]FDG MSC pre-labelling for PET imaging is feasible and allows non-invasive visualization of initial cell distribution after different routes of cell administration in multiple animal models. Those results highlight the potential use of that imaging approach for the understanding and optimization of stem cell therapy in translational research.
In recent years, a paradigm shift from single-photon-emitting radionuclide radiotracers toward positron-emission tomography (PET) radiotracers has occurred in nuclear oncology. Although PET-based molecular imaging of the kidneys is still in its infancy, such a trend has emerged in the field of functional renal radionuclide imaging. Potentially allowing for precise and thorough evaluation of renal radiotracer urodynamics, PET radionuclide imaging has numerous advantages including precise anatomical co-registration with CT images and dynamic three-dimensional imaging capability. In addition, relative to scintigraphic approaches, PET can allow for significantly reduced scan time enabling high-throughput in a busy PET practice and further reduces radiation exposure, which may have a clinical impact in pediatric populations. In recent years, multiple renal PET radiotracers labeled with C-11, Ga-68, and F-18 have been utilized in clinical studies. Beyond providing a precise non-invasive read-out of renal function, such radiotracers may also be used to assess renal inflammation. This manuscript will provide an overview of renal molecular PET imaging and will highlight the transformation of conventional scintigraphy of the kidneys toward novel, high-resolution PET imaging for assessing renal function. In addition, future applications will be introduced, e.g. by transferring the concept of molecular image-guided diagnostics and therapy (theranostics) to the field of nephrology.
Dermal and cardiac autonomic fiber involvement in Parkinson's disease and multiple system atrophy
(2021)
Pathological aggregates of alpha-synuclein in peripheral dermal nerve fibers can be detected in patients with idiopathic Parkinson's disease and multiple system atrophy. This study combines skin biopsy staining for p-alpha-synuclein depositions and radionuclide imaging of the heart with [\(^{123}\)I]-metaiodobenzylguanidine to explore peripheral denervation in both diseases. To this purpose, 42 patients with a clinical diagnosis of Parkinson's disease or multiple system atrophy were enrolled. All patients underwent a standardized clinical workup including neurological evaluation, neurography, and blood samples. Skin biopsies were obtained from the distal and proximal leg, back, and neck for immunofluorescence double labeling with anti-p-alpha-synuclein and anti-PGP9.5. All patients underwent myocardial [\(^{123}\)I]-metaiodobenzylguanidine scintigraphy. Dermal p-alpha-synuclein was observed in 47.6% of Parkinson's disease patients and was mainly found in autonomic structures. 81.0% of multiple system atrophy patients had deposits with most of cases in somatosensory fibers. The [\(^{123}\)I]-metaiodobenzylguanidine heart-to-mediastinum ratio was lower in Parkinson's disease than in multiple system atrophy patients (1.94 +/- 0.63 vs. 2.91 +/- 0.96; p < 0.0001). Irrespective of the diagnosis, uptake was lower in patients with than without p-alpha-synuclein in autonomic structures (1.42 +/- 0.51 vs. 2.74 +/- 0.83; p < 0.0001). Rare cases of Parkinson's disease with p-alpha-synuclein in somatosensory fibers and multiple system atrophy patients with deposits in autonomic structures or both fiber types presented with clinically overlapping features. In conclusion, this study suggests that alpha-synuclein contributes to peripheral neurodegeneration and mediates the impairment of cardiac sympathetic neurons in patients with synucleinopathies. Furthermore, it indicates that Parkinson's disease and multiple system atrophy share pathophysiologic mechanisms of peripheral nervous system dysfunction with a clinical overlap.
Simple Summary
Discordant FDG-positive but PSMA-negative (FDG+/PSMA−) metastases constitute a negative prognostic marker of overall survival in patients undergoing PSMA radioligand therapy (RLT). The aim of this analysis was to investigate the prognostic implications of new FDG+/PSMA− lesions, which occur during or after PSMA RLT. In a retrospective bicentric analysis of 32 patients undergoing PSMA RLT and follow-up dual tracer staging with PSMA and FDG PET/CT, FDG+/PSMA− lesions occurred in a limited number of patients. However, the presence of FDG+/PSMA− lesions appears not to have a significant impact on the OS, but further studies are needed to establish the clinical relevance of such lesions.
Abstract
Introduction: Positron emission tomography/computer tomography (PET/CT) targeting the prostate-specific membrane antigen (PSMA) is crucial for the assessment of adequate PSMA expression in patients with metastatic castration-resistant prostate cancer (mCRPC) prior to PSMA radioligand therapy (PSMA RLT). Moreover, initial dual tracer staging using combined PSMA and [\(^{18}\)F]fluorodeoxyglucose (FDG) PET/CT provides relevant information, since discordant FDG-positive but PSMA-negative (FDG+/PSMA−) lesions constitute a negative prognostic marker of overall survival (OS) after PSMA RLT. However, little is known about the prognostic implications of dual tracer imaging for restaging at follow-up. The aim of this analysis was to investigate the prognostic implications of new FDG+/PSMA− lesions during or after PSMA RLT. Methods: This bicentric analysis included 32 patients with mCRPC who underwent both FDG and PSMA PET/CT imaging after two or four cycles of PSMA RLT. Patients with FDG+/PSMA− lesions prior to PSMA RLT were not considered. The presence of FDG+/PSMA− lesions was assessed with follow-up dual tracer imaging of patients after two or four cycles of PSMA RLT. Patients with at least one new FDG+/PSMA− lesion were compared to patients without any FDG+/PSMA− lesions at the respective time points. A log-rank analysis was used to assess the difference in OS between subgroups. Results: After two cycles of PSMA RLT, four of 32 patients (13%) had FDG+/PSMA− metastases. No significant difference in OS was observed (p = 0.807), as compared to patients without FDG+/PSMA− lesions. Follow-up dual tracer imaging after the 4th cycle of PSMA RLT was available in 18 patients. Of these, four patients presented with FDG+/PSMA− findings (n = 2 already after two cycles). After the fourth cycle of PSMA RLT, no significant difference in OS was observed between patients with and without FDG+/PSMA− lesions (p = 0.442). Conclusion: This study shows that FDG+/PSMA− lesions develop in a limited number of patients undergoing PSMA RLT. Further studies are needed to establish the clinical relevance of such lesions.
We aimed to elucidate the diagnostic potential of the C-X-C motif chemokine receptor 4 (CXCR4)-directed positron emission tomography (PET) tracer \(^{68}\)Ga-Pentixafor in patients with poorly differentiated neuroendocrine carcinomas (NEC), relative to the established reference standard \(^{18}\)F-FDG PET/computed tomography (CT). In our database, we retrospectively identified 11 treatment-naïve patients with histologically proven NEC, who underwent \(^{18}\)F-FDG and CXCR4-directed PET/CT for staging and therapy planning. The images were analyzed on a per-patient and per-lesion basis and compared to immunohistochemical staining (IHC) of CXCR4 from PET-guided biopsies. \(^{68}\)Ga-Pentixafor visualized tumor lesions in 10/11 subjects, while \(^{18}\)F-FDG revealed sites of disease in all 11 patients. Although weak to moderate CXCR4 expression could be corroborated by IHC in 10/11 cases, \(^{18}\)F-FDG PET/CT detected significantly more tumor lesions (102 vs. 42; total lesions, n = 107; p < 0.001). Semi-quantitative analysis revealed markedly higher 18F-FDG uptake as compared to \(^{68}\)Ga-Pentixafor (maximum and mean standardized uptake values (SUV) and tumor-to-background ratios (TBR) of cancerous lesions, SUVmax: 12.8 ± 9.8 vs. 5.2 ± 3.7; SUVmean: 7.4 ± 5.4 vs. 3.1 ± 3.2, p < 0.001; and, TBR 7.2 ± 7.9 vs. 3.4 ± 3.0, p < 0.001). Non-invasive imaging of CXCR4 expression in NEC is inferior to the reference standard \(^{18}\)F-FDG PET/CT.
The norepinephrine transporter (NET) is a major target for the evaluation of the cardiac sympathetic nerve system in patients with heart failure and Parkinson's disease. It is also used in the therapeutic applications against certain types of neuroendocrine tumors, as exemplified by the clinically used \(^{123/131}\)I-MIBG as theranostic single-photon emission computed tomography (SPECT) agent. With the development of more advanced positron emission tomography (PET) technology, more radiotracers targeting NET have been reported, with superior temporal and spatial resolutions, along with the possibility of functional and kinetic analysis. More recently, fluorine-18-labelled NET tracers have drawn increasing attentions from researchers, due to their longer radiological half-life relative to carbon-11 (110 min vs. 20 min), reduced dependence on on-site cyclotrons, and flexibility in the design of novel tracer structures. In the heart, certain NET tracers provide integral diagnostic information on sympathetic innervation and the nerve status. In the central nervous system, such radiotracers can reveal NET distribution and density in pathological conditions. Most radiotracers targeting cardiac NET-function for the cardiac application consistent of derivatives of either norepinephrine or MIBG with its benzylguanidine core structure, e.g. \(^{11}\)C-HED and \(^{18}\)F-LMI1195. In contrast, all NET tracers used in central nervous system applications are derived from clinically used antidepressants. Lastly, possible applications of NET as selective tracers over organic cation transporters (OCTs) in the kidneys and other organs controlled by sympathetic nervous system will also be discussed.
We report on a currently 76-year-old female patient with relapsed/refractory (RR) multiple myeloma (MM) treated at our institution. This patient had received six lines of therapy including tandem autologous stem cell transplant, proteasome inhibitor, immunomodulatory drugs and CD38 antibody MOR202. At the last relapse, she progressed during treatment with pomalidomide and MOR202. In an individualized therapy concept, we started a multi-agent salvage therapy with pomalidomide, bortezomib, doxorubicin, dexamethasone, and CD38 antibody daratumumab (“Pom-PAD-Dara”), which resulted in a stringent complete remission with minimal residual disease (MRD) negativity after nine cycles. So far, our patient shows a progression free survival of more than 12 months. Our case demonstrates the feasibility of successful CD38 antibody retreatment in a patient with heavily pretreated CD38 antibody resistant MM.
Utilizing 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT), we performed this pilot study to evaluate the link between cytogenetic/genomic markers and imaging patterns in relapsed/refractory (RR) multiple myeloma (MM). We retrospectively analyzed data of 24 patients with RRMM who were treated at our institution between November 2018 and February 2020. At the last relapse/progression, patients had been treated with a median of three (range 1–10) lines of therapy. Six (25%) patients showed FDG avid extramedullary disease without adjacency to bone. We observed significantly higher maximum standardized uptake values (SUV\(_{max}\)) in patients harboring del(17p) compared with those without del(17p) (p = 0.025). Moreover, a high SUV\(_{max}\) of >15 indicated significantly shortened progression-free survival (PFS) (p = 0.01) and overall survival (OS) (p = 0.0002). One female patient exhibited biallelic TP53 alteration, i.e., deletion and mutation, in whom an extremely high SUV\(_{max}\) of 37.88 was observed. In summary, this pilot study suggested a link between del(17p)/TP53 alteration and high SUV\(_{max}\) on 18F-FDG PET/CT in RRMM patients. Further investigations are highly warranted at this point.
Differential diagnosis of parkinsonism: a head-to-head comparison of FDG PET and MIBG scintigraphy
(2020)
[\(^{18}\)F]fluorodeoxyglucose (FDG) PET and [\(^{123}\)I]metaiodobenzylguanidine (MIBG) scintigraphy may contribute to the differential diagnosis of neurodegenerative parkinsonism. To identify the superior method, we retrospectively evaluated 54 patients with suspected neurodegenerative parkinsonism, who were referred for FDG PET and MIBG scintigraphy. Two investigators visually assessed FDG PET scans using an ordinal 6-step score for disease-specific patterns of Lewy body diseases (LBD) or atypical parkinsonism (APS) and assigned the latter to the subgroups multiple system atrophy (MSA), progressive supranuclear palsy (PSP), or corticobasal syndrome. Regions-of-interest analysis on anterior planar MIBG images served to calculate the heart-to-mediastinum ratio. Movement disorder specialists blinded to imaging results established clinical follow-up diagnosis by means of guideline-derived case vignettes. Clinical follow-up (1.7 +/- 2.3 years) revealed the following diagnoses: n = 19 LBD (n = 17 Parkinson's disease [PD], n = 1 PD dementia, and n = 1 dementia with Lewy bodies), n = 31 APS (n = 28 MSA, n = 3 PSP), n = 3 non-neurodegenerative parkinsonism; n = 1 patient could not be diagnosed and was excluded. Receiver operating characteristic analyses for discriminating LBD vs. non-LBD revealed a larger area under the curve for FDG PET than for MIBG scintigraphy at statistical trend level for consensus rating (0.82 vs. 0.69, p = 0.06; significant for investigator #1: 0.83 vs. 0.69, p = 0.04). The analysis of PD vs. MSA showed a similar difference (0.82 vs. 0.69, p = 0.11; rater #1: 0.83 vs. 0.69, p = 0.07). Albeit the notable differences in diagnostic performance did not attain statistical significance, the authors consider this finding clinically relevant and suggest that FDG PET, which also allows for subgrouping of APS, should be preferred.
We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.
Background
Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT\(^+\)).
Methods
The new U-SPECT5-E with two stationary detectors was used for acquiring data with \(^{99m}\)Tc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT\(^+\) for comparison.
Results
Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT\(^+\). In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT\(^+\)) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR.
Conclusions
While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.
Peptide Receptor Radionuclide Therapy (PRRT) for the treatment of neuroendocrine tumors may lead to kidney deterioration. This study aimed to evaluate the suitability of \(^{99m}\)Tc-mercaptoacetyltriglycine (\(^{99m}\)Tc-MAG3) clearance for the early detection of PRRT-induced changes on tubular extraction (TE). TE rate (TER) was measured prior to 128 PRRT cycles (7.6±0.4 GBq \(^{177}\)Lu-octreotate/octreotide each) in 32 patients. TER reduction during PRRT was corrected for age-related decrease and analyzed for the potential to predict loss of glomerular filtration (GF). The GF rate (GFR) as measure for renal function was derived from serum creatinine. The mean TER was 234 ± 53 ml/min/1.73 m² before PRRT (baseline) and 221 ± 45 ml/min/1.73 m² after a median follow-up of 370 days. The age-corrected decrease (mean: -3%, range: -27% to +19%) did not reach significance (p=0.09) but significantly correlated with the baseline TER (Spearman p=-0.62, p<0.001). Patients with low baseline TER showed an improved TER after PRRT, high decreases were only observed in individuals with high baseline TER. Pre-therapeutic TER data were inferior to plasma creatinine-derived GFR estimates in predicting late nephropathy. TER assessed by \(^{99m}\)Tc-MAG3clearance prior to and during PRRT is not suitable as early predictor of renal injury and an increased risk for late nephropathy.
Diagnosis of cardiac sarcoidosis is often challenging. Whereas cardiac magnetic resonance imaging (CMR) and positron emission tomography/computed tomography (PET/CT) with \(^{18}\)F-fluorodeoxyglucose (FDG) are most commonly used to evaluate patients, PET/CT using radiolabeled somatostatin receptor (SSTR) ligands for visualization of inflammation might represent a more specific alternative. This study aimed to investigate the feasibility of SSTR–PET/CT for detecting cardiac sarcoidosis in comparison to CMR.
15 patients (6 males, 9 females) with sarcoidosis and suspicion on cardiac involvement underwent SSTR-PET/CT imaging and CMR. Images were visually scored. The AHA 17-segment model of the left myocardium was used for localization and comparison of inflamed myocardium for both imaging modalities. In semi-quantitative analysis, mean (SUV\(_{mean}\)) and maximum standardized uptake values (SUV\(_{max}\)) of affected myocardium were calculated and compared with both remote myocardium and left ventricular (LV) cavity.
SSTR-PET was positive in 7/15, CMR in 10/15 patients. Of the 3 CMR+/PET- subjects, one patient with minor involvement (<25% of wall thickness in CMR) was missed by PET. The remaining two CMR+/PET- patients displayed no adverse cardiac events during follow-up.
In the 17-segment model, PET/CT yielded 27 and CMR 29 positive segments. Overall concordance of the 2 modalities was 96.1% (245/255 segments analyzed). SUV\(_{mean}\) and SUV\(_{max}\) in inflamed areas were 2.0±1.2 and 2.6±1.2, respectively. The lesion-to-remote myocardium and lesion-to-LV cavity ratios were 1.8±0.2 and 1.9±0.2 for SUV\(_{mean}\) and 2.0±0.3 and 1.7±0.3 for SUV\(_{max}\), respectively.
Detection of cardiac sarcoidosis by SSTR-PET/CT is feasible. Our data warrant further analysis in larger prospective series.
Prostate-specific membrane antigen (PSMA) ligand PET/CT enables the localization of tumor lesions in patients with recurrent prostate cancer, but it is unclear whether androgen deprivation therapy (ADT) influences diagnostic accuracy. The aim of this study was to evaluate the effect of ADT on the detection rate of \(^{68}\)Ga-PSMA ligand PET/CT. Thus, 399 patients with initial radical prostatectomy and 68Ga-PSMA ligand PET/CT during PSA relapse were retrospectively evaluated. Propensity score matching was used to create two balanced groups of 62 subjects who either did or did not receive ADT within six months before imaging. All \(^{68}\)Ga-PSMA ligand PET/CT were evaluated visually and with semiquantitative measures. The detection rate of tumor recurrence was significantly higher in the group with ADT (88.7% vs. 72.6%, p = 0.02) and improved with increasing PSA-levels in both groups. In subjects with pathological PET/CT and ADT, whole-body total lesion PSMA (p < 0.01) and PSMA-derived tumor volume (p < 0.01) were significantly higher than in those without ADT. More PSMA-positive lesions and higher PSMA-derived volumetric parameters in patients with ADT suggest that a better detection rate is related to a (biologically) more advanced disease stage. Due to high detection rates in patients with PSA-levels < 2 ng/mL, the withdrawal of ADT before PSMA ligand PET/CT cannot be recommended.
(1) Background: Prostate-specific membrane antigen (PSMA)-derived tumour volume (PSMA-TV) and total lesion PSMA (TL-PSMA) from PSMA PET/CT scans are promising biomarkers for assessing treatment response in prostate cancer (PCa). Currently, it is unclear whether different software tools for assessing PSMA-TV and TL-PSMA produce comparable results. (2) Methods: \(^{68}\)Ga-PSMA PET/CT scans from n = 21 patients with castration-resistant PCa (CRPC) receiving chemotherapy were identified from our single-centre database. PSMA-TV and TL-PSMA were calculated with Syngo.via (Siemens) as well as the freely available Beth Israel plugin for FIJI (Fiji Is Just ImageJ) before and after chemotherapy. While statistical comparability was illustrated and quantified via Bland-Altman diagrams, the clinical agreement was estimated by matching PSMA-TV, TL-PSMA and relative changes of both variables during chemotherapy with changes in serum PSA (ΔPSA) and PERCIST (Positron Emission Response Criteria in Solid Tumors). (3) Results: Comparing absolute PSMA-TV and TL-PSMA as well as Bland–Altman plotting revealed a good statistical comparability of both software algorithms. For clinical agreement, classifying therapy response did not differ between PSMA-TV and TL-PSMA for both software solutions and showed highly positive correlations with BR. (4) Conclusions: due to the high levels of statistical and clinical agreement in our CRPC patient cohort undergoing taxane chemotherapy, comparing PSMA-TV and TL-PSMA determined by Syngo.via and FIJI appears feasible.
Chemokine (C-X-C motif) receptor 4 (CXCR4) is a key factor for tumor growth and metastasis in several types of human cancer including multiple myeloma (MM). Proof-of-concept of CXCR4-directed radionuclide therapy in MM has recently been reported. This study assessed the diagnostic performance of the CXCR4-directed radiotracer [\(^{68}\)Ga]Pentixafor in MM and a potential role for stratifying patients to CXCR4-directed therapies.
Thirty-five patients with MM underwent [\(^{68}\)Ga]Pentixafor-PET/CT for evaluation of eligibility for endoradiotherapy. In 19/35 cases, [\(^{18}\)F]FDG-PET/CT for correlation was available. Scans were compared on a patient and on a lesion basis. Tracer uptake was correlated with standard clinical parameters of disease activity.
[\(^{68}\)Ga]Pentixafor-PET detected CXCR4-positive disease in 23/35 subjects (66%). CXCR4-positivity at PET was independent from myeloma subtypes, cytogenetics or any serological parameters and turned out as a negative prognostic factor. In the 19 patients in whom a comparison to [\(^{18}\)F]FDG was available, [\(^{68}\)Ga]Pentixafor-PET detected more lesions in 4/19 (21%) subjects, [\(^{18}\)F]FDG proved superior in 7/19 (37%). In the remaining 8/19 (42%) patients, both tracers detected an equal number of lesions. [\(^{18}\)F]FDG-PET positivity correlated with [\(^{68}\)Ga]Pentixafor-PET positivity (p=0.018).
[\(^{68}\)Ga]Pentixafor-PET provides further evidence that CXCR4 expression frequently occurs in advanced multiple myeloma, representing a negative prognostic factor and a potential target for myeloma specific treatment. However, selecting patients for CXCR4 directed therapies and prognostic stratification seem to be more relevant clinical applications for this novel imaging modality, rather than diagnostic imaging of myeloma.
C-X-C-motif chemokine receptor 4 (CXCR4) is a key factor for tumor growth and metastasis in several types of human cancer. We have recently reported promising first-in-man experience with CXCR4-directed endoradiotherapy (ERT) in multiple myeloma (MM).
Eight heavily pretreated MM patients underwent a total of 10 ERT cycles (7 patients with 1 cycle and a single patient with 3 cycles). ERT was administered in combination with chemotherapy and autologous stem cell support. End points were occurrence and timing of adverse events, progression-free and overall survival.
ERT was overall well tolerated without any unexpected acute adverse events or changes in vital signs. With absorbed tumor doses >30-70 Gy in intra- or extramedullary lesions, significant anti-myeloma activity was observed with 1 patient achieving complete remission and 5/8 partial remission. Directly after ERT major infectious complications were seen in one patient who died from sepsis 22 days after ERT, another patient with high tumor burden experienced lethal tumor lysis syndrome. Median progression-free survival was 54 days (range, 13-175), median overall survival was 223 days (range, 13-313). During follow-up (6 patients available), one patient died from infectious complications, 2/8 from disease progression, the remaining 3/8 patients are still alive.
CXCR4-directed ERT was well-tolerated and exerted anti-myeloma activity even at very advanced stage MM with presence of extramedullary disease. Further assessment of this novel treatment option is highly warranted.
\(^{11}\)C-methionine-PET in multiple myeloma: a combined study from two different institutions
(2017)
\(^{11}\)C-methionine (MET) has recently emerged as an accurate marker of tumor burden and disease activity in patients with multiple myeloma (MM). This dual-center study aimed at further corroboration of the superiority of MET as positron emission tomography (PET) tracer for staging and re-staging MM, as compared to \(^{18}\)F-2`-deoxy-2`-fluoro-D-glucose (FDG).
78 patients with a history of solitary plasmacytoma (n=4), smoldering MM (SMM, n=5), and symptomatic MM (n=69) underwent both MET- and FDG-PET/computed tomography (CT) at the University Centers of Würzburg, Germany and Navarra, Spain. Scans were compared on a patient and on a lesion basis. Inter-reader agreement was also evaluated. In 2 patients, tumor biopsies for verification of discordant imaging results were available.
MET-PET detected focal lesions (FL) in 59/78 subjects (75.6%), whereas FDG-PET/CT showed lesions in only 47 patients (60.3%; p<0.01), accordingly disease activity would have been missed in 12 patients. Directed biopsies of discordant results confirmed MET-PET/CT results in both cases.
MET depicted more FL in 44 patients (56.4%; p<0.01), whereas in two patients (2/78), FDG proved superior. In the remainder (41.0%, 32/78), both tracers yielded comparable results. Inter-reader agreement for MET was higher than for FDG (κ = 0.82 vs κ = 0.72).
This study demonstrates higher sensitivity of MET in comparison to standard FDG to detect intra- and extramedullary MM including histologic evidence of FDG-negative, viable disease exclusively detectable by MET-PET/CT. MET holds the potential to replace FDG as functional imaging standard for staging and re-staging of MM.
Combined MEK‐BRAF inhibition is a well‐established treatment strategy in BRAF‐mutated cancer, most prominently in malignant melanoma with durable responses being achieved through this targeted therapy. However, a subset of patients face primary unresponsiveness despite presence of the activating mutation at position V600E, and others acquire resistance under treatment. Underlying resistance mechanisms are largely unknown, and diagnostic tests to predict tumor response to BRAF‐MEK inhibitor treatment are unavailable.
Multiple myeloma represents the second most common hematologic malignancy, and point mutations in BRAF are detectable in about 10% of patients. Targeted inhibition has been successfully applied, with mixed responses observed in a substantial subset of patients mirroring the widespread spatial heterogeneity in this genomically complex disease. Central nervous system (CNS) involvement is an extremely rare, extramedullary form of multiple myeloma that can be diagnosed in less than 1% of patients. It is considered an ultimate high‐risk feature, associated with unfavorable cytogenetics, and, even with intense treatment applied, survival is short, reaching less than 12 months in most cases. Here we not only describe the first patient with an extramedullary CNS relapse responding to targeted dabrafenib and trametinib treatment, we furthermore provide evidence that a point mutation within the capicua transcriptional repressor (CIC) gene mediated the acquired resistance in this patient.
The aim was to investigate the induction and repair of radiation-induced DNA double-strand breaks (DSBs) as a function of the absorbed dose to the blood of patients undergoing PET/CT examinations with [68Ga]Ga-PSMA. Blood samples were collected from 15 patients before and at four time points after [68Ga]Ga-PSMA administration, both before and after the PET/CT scan. Absorbed doses to the blood were calculated. In addition, blood samples with/without contrast agent from five volunteers were irradiated ex vivo by CT while measuring the absorbed dose. Leukocytes were isolated, fixed, and stained for co-localizing γ-H2AX+53BP1 DSB foci that were enumerated manually. In vivo, a significant increase in γ-H2AX+53BP1 foci compared to baseline was observed at all time points after administration, although the absorbed dose to the blood by 68Ga was below 4 mGy. Ex vivo, the increase in radiation-induced foci depended on the absorbed dose and the presence of contrast agent, which could have caused a dose enhancement. The CT-dose contribution for the patients was estimated at about 12 mGy using the ex vivo calibration. The additional number of DSB foci induced by CT, however, was comparable to the one induced by 68Ga. The significantly increased foci numbers after [68Ga]Ga-PSMA administration may suggest a possible low-dose hypersensitivity.
We aimed to determine a detailed regional ventricular distribution pattern of the novel cardiac nerve PET radiotracer \(^{18}\)F-LMI1195 in healthy rabbits. Ex-vivo high resolution autoradiographic imaging was conducted to identify accurate ventricular distribution of \(^{18}\)F-LMI1195. In healthy rabbits, \(^{18}\)F-LMI1195 was administered followed by the reference perfusion marker \(^{201}\)Tl for a dual-radiotracer analysis. After 20 min of \(^{18}\)F-LMI1195 distribution time, the rabbits were euthanized, the hearts were extracted, frozen, and cut into 20-μm short axis slices. Subsequently, the short axis sections were exposed to a phosphor imaging plate to determine \(^{18}\)F-LMI1195 distribution (exposure for 3 h). After complete \(^{18}\)F decay, sections were re-exposed to determine 201Tl distribution (exposure for 7 days). For quantitative analysis, segmental regions of Interest (ROIs) were divided into four left ventricular (LV) and a right ventricular (RV) segment on mid-ventricular short axis sections. Subendocardial, mid-portion, and subepicardial ROIs were placed on the LV lateral wall. \(^{18}\)F-LMI1195 distribution was almost homogeneous throughout the LV wall without any significant differences in all four LV ROIs (anterior, posterior, septal and lateral wall, 99 ± 2, 94 ± 5, 94 ± 4 and 97 ± 3%LV, respectively, n.s.). Subepicardial \(^{201}\)Tl uptake was significantly lower compared to the subendocardial portion (subendocardial, mid-portion, and subepicardial activity: 90 ± 3, 96 ± 2 and *80 ± 5%LV, respectively, *p < 0.01 vs. mid-portion). This was in contradistinction to the transmural wall profile of \(^{18}\)F-LMI1195 (90 ± 4, 96 ± 5 and 84 ± 4%LV, n.s.). A slight but significant discrepant transmural radiotracer distribution pattern of \(^{201}\)Tl in comparison to \(^{18}\)F-LMI1195 may be a reflection of physiological sympathetic innervation and perfusion in rabbit hearts.
Prostate-specific membrane antigen (PSMA)-targeted PET imaging for prostate cancer with \(^{68}\)Ga-labeled compounds has rapidly become adopted as part of routine clinical care in many parts of the world. However, recent years have witnessed the start of a shift from \(^{68}\)Ga- to \(^{18}\)F-labeled PSMA-targeted compounds. The latter imaging agents have several key advantages, which may lay the groundwork for an even more widespread adoption into the clinic. First, facilitated delivery from distant suppliers expands the availability of PET radiopharmaceuticals in smaller hospitals operating a PET center but lacking the patient volume to justify an onsite \(^{68}\)Ge/\(^{68}\)Ga generator. Thus, such an approach meets the increasing demand for PSMA-targeted PET imaging in areas with lower population density and may even lead to cost-savings compared to in-house production. Moreover, \(^{18}\)F-labeled radiotracers have a higher positron yield and lower positron energy, which in turn decreases image noise, improves contrast resolution, and maximizes the likelihood of detecting subtle lesions. In addition, the longer half-life of 110 min allows for improved delayed imaging protocols and flexibility in study design, which may further increase diagnostic accuracy. Moreover, such compounds can be distributed to sites which are not allowed to produce radiotracers on-site due to regulatory issues or to centers without access to a cyclotron. In light of these advantageous characteristics, \(^{18}\)F-labeled PSMA-targeted PET radiotracers may play an important role in both optimizing this transformative imaging modality and making it widely available. We have aimed to provide a concise overview of emerging \(^{18}\)F-labeled PSMA-targeted radiotracers undergoing active clinical development. Given the wide array of available radiotracers, comparative studies are needed to firmly establish the role of the available \(^{18}\)F-labeled compounds in the field of molecular PCa imaging, preferably in different clinical scenarios.
We have recently demonstrated CXCR4 overexpression in vestibular schwannomas (VS). This study investigated the feasibility of CXCR4-directed positron emission tomography/computed tomography (PET/CT) imaging of VS using the radiolabeled chemokine ligand [\(^{68}\)Ga]Pentixafor.
Methods: 4 patients with 6 primarily diagnosed or pre-treated/observed VS were enrolled. All subjects underwent [\(^{68}\)Ga]Pentixafor PET/CT prior to surgical resection. Images were analyzed visually and semi-quantitatively for CXCR4 expression including calculation of tumor-to-background ratios (TBR). Immunohistochemistry served as standard of reference in three patients.
Results: [\(^{68}\)Ga]Pentixafor PET/CT was visually positive in all cases. SUV\(_{mean}\) and SUV\(_{max}\) were 3.0 ± 0.3 and 3.8 ± 0.4 and TBR\(_{mean}\) and TBR\(_{max}\) were 4.0 ± 1.4 and 5.0 ± 1.7, respectively. Histological analysis confirmed CXCR4 expression in tumors.
Conclusion: Non-invasive imaging of CXCR4 expression using [\(^{68}\)Ga]Pentixafor PET/CT of VS is feasible and could prove useful for in vivo assessment of CXCR4 expression.
Despite histological evidence in various solid tumor entities, available experience with CXCR4-directed diagnostics and endoradiotherapy mainly focuses on hematologic diseases. With the goal of expanding the application of CXCR4 theranostics to solid tumors, we aimed to elucidate the feasibility of CXCR4-targeted imaging in a variety of such neoplasms.
Methods: Nineteen patients with newly diagnosed, treatment-naïve solid tumors including pancreatic adenocarcinoma or neuroendocrine tumor, cholangiocarcinoma, hepatocellular carcinoma, renal cell carcinoma, ovarian cancer, and prostate cancer underwent [\(^{68}\)Ga]Pentixafor PET/CT. CXCR4-mediated uptake was assessed both visually and semi-quantitatively by evaluation of maximum standardized uptake values (SUV\(_{max}\)) of both primary tumors and metastases. With physiologic liver uptake as reference, tumor-to-background ratios (TBR) were calculated. [\(^{68}\)Ga]Pentixafor findings were further compared to immunohistochemistry and [\(^{18}\)F]FDG PET/CT.
Results: On [\(^{68}\)Ga]Pentixafor PET/CT, 10/19 (52.6%) primary tumors were visually detectable with a median SUVmax of 5.4 (range, 1.7–16.0) and a median TBR of 2.6 (range, 0.8–7.4), respectively. The highest level of radiotracer uptake was identified in a patient with cholangiocarcinoma (SUVmax, 16.0; TBR, 7.4). The relatively low uptake on [\(^{68}\)Ga]Pentixafor was also noted in metastases, exhibiting a median SUVmax of 4.5 (range, 2.3–8.8; TBR, 1.7; range, 1.0–4.1). A good correlation between uptake on [\(^{68}\)Ga]Pentixafor and histological derived CXCR4 expression was noted (R = 0.62, P < 0.05). In the 3 patients in whom [\(^{18}\)F]FDG PET/CT was available, [\(^{68}\)Ga]Pentixafor exhibited lower uptake in all lesions.
Conclusions: In this cohort of newly diagnosed, treatment-naïve patients with solid malignancies, CXCR4 expression as detected by [\(^{68}\)Ga]Pentixafor-PET/CT and immunohistochemistry was rather moderate. Thus, CXCR4-directed imaging may not play a major role in the management of solid tumors in the majority of patients.
Objectives: Recently, the standardized reporting and data system for prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging studies, termed PSMA-RADS version 1.0, was introduced. We aimed to determine the interobserver agreement for applying PSMA-RADS to imaging interpretation of 18F-DCFPyL PET examinations in a prospective setting mimicking the typical clinical work-flow at a prostate cancer referral center.
Methods: Four readers (two experienced readers (ER, > 3 years of PSMA-targeted PET interpretation experience) and two inexperienced readers (IR, < 1 year of experience)), who had all read the initial publication on PSMA-RADS 1.0, assessed 50 18F-DCFPyL PET/computed tomography (CT) studies independently. Per scan, a maximum of 5 target lesions were selected by the observers and a PSMA-RADS score for every target lesion was recorded. No specific pre-existing conditions were placed on the selection of the target lesions, although PSMA-RADS 1.0 suggests that readers focus on the most highly avid or largest lesions. An overall scan impression based on PSMA-RADS was indicated and interobserver agreement rates on a target lesion-based, on an organ-based, and on an overall PSMA-RADS score-based level were computed.
Results: The number of target lesions identified by each observer were as follows: ER 1, 123; ER 2, 134; IR 1, 123; and IR 2, 120. Among those selected target lesions, 125 were chosen by at least two individual observers (all four readers selected the same target lesion in 58/125 (46.4%) instances, three readers in 40/125 (32%) and two observers in 27/125 (21.6%) instances). The interobserver agreement for PSMA-RADS scoring among identical target lesions was good (intraclass correlation coefficient (ICC) for four, three and two identical target lesions, ≥0.60, respectively). For lymph nodes, an excellent interobserver agreement was derived (ICC=0.79). The interobserver agreement for an overall scan impression based on PSMA-RADS was also excellent (ICC=0.84), with a significant difference for ER (ICC=0.97) vs. IR (ICC=0.74, P=0.005).
Conclusions: PSMA-RADS demonstrates a high concordance rate in this study, even among readers with different levels of experience. This suggests that PSMA-RADS can be effectively used for communication with clinicians and can be implemented in the collection of data for large prospective trials.
C-X-C motif chemokine receptor 4 (CXCR4) is a key factor for tumor growth and metastasis in several types of human cancer. This study investigated the feasibility of CXCR4-directed imaging with positron emission tomography/computed tomography (PET/CT) using [\(^{68}\)Ga]Pentixafor in malignant pleural mesothelioma.
Six patients with pleural mesothelioma underwent [\(^{68}\)Ga]Pentixafor-PET/CT. 2′-[\(^{18}\)F]fluoro-2′-deoxy-D-glucose ([\(^{18}\)F]FDG)-PET/CT (4/6 patients) and immunohistochemistry obtained from biopsy or surgery (all) served as standards of reference. Additionally, 9 surgical mesothelioma samples were available for histological work-up.
Whereas [\(^{18}\)F]FDG-PET depicted active lesions in all patients, [\(^{68}\)Ga]Pentixafor-PET/CT recorded physiologic tracer distribution and none of the 6 patients presented [\(^{68}\)Ga]Pentixafor-positive lesions. This finding paralleled results of immunohistochemistry which also could not identify relevant CXCR4 surface expression in the samples analyzed.
In contrast to past reports, our data suggest widely absence of CXCR4 expression in pleural mesothelioma. Hence, robust cell surface expression should be confirmed prior to targeting this chemokine receptor for diagnosis and/or therapy.
Chemokine receptor-4 (CXCR4) has been reported to be overexpressed in glioblastoma (GBM) and to be associated with poor survival. This study investigated the feasibility of non-invasive CXCR4-directed imaging with positron emission tomography/computed tomography (PET/CT) using the radiolabelled chemokine receptor ligand \(^{68}\)Ga-Pentixafor.
15 patients with clinical suspicion on primary or recurrent glioblastoma (13 primary, 2 recurrent tumors) underwent \(^{68}\)Ga-Pentixafor-PET/CT for assessment of CXCR4 expression prior to surgery. O-(2-\(^{18}\)F-fluoroethyl)-L-tyrosine (\(^{18}\)F-FET) PET/CT images were available in 11/15 cases and were compared visually and semi-quantitatively (SUV\(_{max}\), SUV\(_{mean}\)). Tumor-to-background ratios (TBR) were calculated for both PET probes. \(^{68}\)Ga-Pentixafor-PET/CT results were also compared to histological CXCR4 expression on neuronavigated surgical samples.
\(^{68}\)Ga-Pentixafor-PET/CT was visually positive in 13/15 cases with SUV\(_{mean}\) and SUV\(_{max}\) of 3.0±1.5 and 3.9±2.0 respectively. Respective values for \(^{18}\)F-FET were 4.4±2.0 (SUV\(_{mean}\)) and 5.3±2.3 (SUV\(_{max}\)). TBR for SUV\(_{mean}\) and SUV\(_{max}\) were higher for \(^{68}\)Ga-Pentixafor than for \(^{18}\)F-FET (SUV\(_{mean}\) 154.0±90.7 vs. 4.1±1.3; SUV\(_{max}\) 70.3±44.0 and 3.8±1.2, p<0.01), respectively. Histological analysis confirmed CXCR4 expression in tumor areas with high \(^{68}\)Ga-Pentixafor uptake; regions of the same tumor without apparent \(^{68}\)Ga-Pentixafor uptake showed no or low receptor expression.
In this pilot study, \(^{68}\)Ga-Pentixafor retention has been observed in the vast majority of glioblastoma lesions and served as readout for non-invasive determination of CXCR4 expression. Given the paramount importance of the CXCR4/SDF-1 axis in tumor biology, \(^{68}\)Ga-Pentixafor-PET/CT might prove a useful tool for sensitive, non-invasive in-vivo quantification of CXCR4 as well as selection of patients who might benefit from CXCR4-directed therapy.
Purpose: Prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) imaging has become commonly utilized in patients with prostate cancer (PCa). The PSMA reporting and data system version 1.0 (PSMA-RADS version 1.0) categorizes lesions on the basis of the likelihood of PCa involvement, with PSMA-RADS-3A (soft tissue) and PSMA-RADS-3B (bone) lesions being indeterminate for the presence of disease. We retrospectively reviewed the imaging follow-up of such lesions to determine the rate at which they underwent changes suggestive of underlying PCa.
Methods: PET/CT imaging with \(^{18}\)F-DCFPyL was carried out in 110 patients with PCa and lesions were categorized according to PSMA-RADS Version 1.0. 56/110 (50.9%) patients were determined to have indeterminate PSMA-RADS-3A or PSMA-RADS-3B lesions and 22/56 (39.3%) patients had adequate follow-up to be included in the analysis. The maximum standardized uptake values (SUV\(_{max}\)) of the lesions were obtained and the ratios of SUV\(_{max}\) of the lesions to SUV\(_{mean}\) of blood pool (SUV\(_{max}\)-lesion/SUV\(_{mean}\)-bloodpool) were calculated. Pre-determined criteria were used to evaluate the PSMA-RADS-3A and PSMA-RADS-3B lesions on follow-up imaging to determine if they demonstrated evidence of underlying malignancy.
Results: A total of 46 lesions in 22 patients were considered indeterminate for PCa (i.e. PSMA-RADS-3A (32 lesions) or PSMA-RADS-3B (14 lesions)) and were evaluable on follow-up imaging. 27/46 (58.7%) lesions demonstrated changes on follow-up imaging consistent with the presence of underlying PCa at baseline. These lesions included 24/32 (75.0%) PSMA-RADS-3A lesions and 3/14 (21.4%) lesions categorized as PSMA-RADS-3B. The ranges of SUVmax and SUVmax-lesion/SUVmean-bloodpool overlapped between those lesions demonstrating changes consistent with malignancy on follow-up imaging and those lesions that remained unchanged on follow-up.
Conclusion: PSMA-RADS-3A and PSMA-RADS-3B lesions are truly indeterminate in that proportions of findings in both categories demonstrate evidence of malignancy on follow-up imaging. Overall, PSMA-RADS-3A lesions are more likely than PSMA-RADS-3B lesions to represent sites of PCa and this information should be taken into when guiding patient therapy.
The novel PET probe 2-deoxy-2-18F-fluoro-D-sorbitol (18F-FDS) has demonstrated favorable renal kinetics in animals. We aimed to elucidate its imaging properties in two human volunteers. 18F-FDS was produced by a simple one-step reduction from 18F-FDG. On dynamic renal PET, the cortex was delineated and activity gradually transited in the parenchyma, followed by radiotracer excretion. No adverse effects were reported. Given the higher spatiotemporal resolution of PET relative to conventional scintigraphy, 18F-FDS PET offers a more thorough evaluation of human renal kinetics. Due to its simple production from 18F-FDG, 18F-FDS is virtually available at any PET facility with radiochemistry infrastructure.
Standardized reporting is more and more routinely implemented in clinical practice and such structured reports have a major impact on a large variety of medical fields, e.g. laboratory medicine, pathology, and, recently, radiology. Notably, the field of nuclear medicine is constantly evolving, as novel radiotracers for numerous clinical applications are developed. Thus, framework systems for standardized reporting in this field may a) increase clinical acceptance of new radiotracers, b) allow for inter- and intra-center comparisons for quality assurance, and c) may be used in (global) multi-center studies to ensure comparable results and enable efficient data abstraction. In the last two years, several standardized framework systems for positron emission tomography (PET) radiotracers with potential theranostic applications have been proposed. These include systems for prostate-specific membrane antigen (PSMA)-targeted PET agents for the diagnosis and treatment of prostate cancer (PCa) and somatostatin receptor (SSTR)-targeted PET agents for the diagnosis and treatment of neuroendocrine neoplasias. In the present review, those standardized framework systems for PSMA- and SSTR-targeted PET will be briefly introduced followed by an overview of their advantages and limitations. In addition, potential applications will be defined, approaches to validate such concepts will be proposed, and future perspectives will be discussed.
PURPOSE:
We aimed to (a) elucidate the concordance of visual assessment of an initial I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists.
METHODS:
An initial I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software.
RESULTS:
When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7%, ĸ = 0.75) compared to semiquantification (86.2%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found.
CONCLUSIONS:
In comparison with a fully automatic semiquantitative method in I-ioflupane interpretation, human assessment obtained an almost perfect agreement rate. However, compared to clinical established diagnosis serving as a reference, visual read seemed to be slightly more accurate as a solely software-based quantitative assessment.