Refine
Has Fulltext
- yes (4)
Is part of the Bibliography
- yes (4)
Year of publication
- 2024 (4) (remove)
Document Type
- Doctoral Thesis (4)
Keywords
- 3D-Druck (4) (remove)
Biofabrication technologies must address numerous parameters and conditions to reconstruct tissue complexity in vitro. A critical challenge is vascularization, especially for large constructs exceeding diffusion limits. This requires the creation of artificial vascular structures, a task demanding the convergence and integration of multiple engineering approaches. This doctoral dissertation aims to achieve two primary objectives: firstly, to implement and refine engineering methods for creating artificial microvascular structures using Melt Electrowriting (MEW)-assisted sacrificial templating, and secondly, to deepen the understanding of the critical factors influencing the printability of bioink formulations in 3D extrusion bioprinting.
In the first part of this dissertation, two innovative sacrificial templating techniques using MEW are explored. Utilizing a carbohydrate glass as a fugitive material, a pioneering advancement in the processing of sugars with MEW with a resolution under 100 microns was made. Furthermore, by introducing the “print-and-fuse” strategy as a groundbreaking method, biomimetic branching microchannels embedded in hydrogel matrices were fabricated, which can then be endothelialized to mirror in vivo vascular conditions.
The second part of the dissertation explores extrusion bioprinting. By introducing a simple binary bioink formulation, the correlation between physical properties and printability was showcased. In the next step, employing state-of-the-art machine-learning approaches revealed a deeper understanding of the correlations between bioink properties and printability in an extended library of hydrogel formulations.
This dissertation offers in-depth insights into two key biofabrication technologies. Future work could merge these into hybrid methods for the fabrication of vascularized constructs, combining MEW's precision with fine-tuned bioink properties in automated extrusion bioprinting.
In vitro models mimic the tissue-specific anatomy and play essential roles in personalized medicine and disease treatments. As a sophisticated manufacturing technology, 3D printing overcomes the limitations of traditional technologies and provides an excellent potential for developing in vitro models to mimic native tissue. This thesis aims to investigate the potential of a high-resolution 3D printing technology, melt electrowriting (MEW), for fabricating in vitro models. MEW has a distinct capacity for depositing micron size fibers with a defined design. In this thesis, three approaches were used, including 1) extending the MEW polymer library for different biomedical applications, 2) developing in vitro models for evaluation of cell growth and migration toward the different matrices, and 3) studying the effect of scaffold designs and biochemical cues of microenvironments on cells.
First, we introduce the MEW processability of (AB)n and (ABAC)n segmented copolymers, which have thermally reversible network formulation based on physical crosslinks. Bisurea segments are combined with hydrophobic poly(dimethylsiloxane) (PDMS) or hydrophilic poly(propylene oxide)-poly(ethylene oxide)-poly(propylene oxide) (PPO-PEG-PPO) segments to form the (AB)n segmented copolymers. (ABAC)n segmented copolymers contain all three segments: in addition to bisurea, both hydrophobic and hydrophilic segments are available in the same polymer chain, resulting in tunable mechanical and biological behaviors. MEW copolymers either support cells attachment or dissolve without cytotoxic side effects when in contact with the polymers at lower concentrations, indicating that this copolymer class has potential in biological applications. The unique biological and surface properties, transparency, adjustable hydrophilicity of these copolymers could be beneficial in several in vitro models.
The second manuscript addresses the design and development of a melt electrowritten competitive 3D radial migration device. The approach differs from most of the previous literature, as MEW is not used here to produce cell invasive scaffolds but to fabricate an in vitro device. The device is utilized to systematically determine the matrix which promotes cell migration and growth of glioblastoma cells. The glioblastoma cell migration is tested on four different Matrigel concentrations using a melt electrowritten radial device. The glioblastoma U87 cell growth and migration increase at Matrigel concentrations 6 and 8 mg mL-1 In the development of this radial device, the accuracy, and precision of melt electrowritten circular shapes were investigated. The results show that the printing speed and design diameter are essential parameters for the accuracy of printed constructs. It is the first instance where MEW is used for the production of in vitro devices.
The influence of biochemical cues and scaffold designs on astrocytes and glioblastoma is investigated in the last manuscript. A fiber comprising the box and triangle-shaped pores within MEW scaffolds are modified with biochemical cues, including RGD and IKVAV peptides using a reactive NCO-sP(EO-stat-PO) macromer. The results show that astrocytes and glioblastoma cells exhibit different phenotypes on scaffold designs and peptide-coated scaffolds.
In der vorliegenden Arbeit präparierten Studierende 3D-gedruckte Übungszähne, in denen die korrekte Präparation eines Veneers farblich abgesetzt war. Die neue Lehrmethode wurde durch die Teilnehmer in einem Fragebogen evaluiert und zusätzlich wurden die Präparationen digital mit einer Referenzpräparation verglichen. Die Teilnehmer des praktischen Kurses schätzten die Zweischichttechnik als gute Lehrmethode ein (Ø 2,0 ± 0,37) und gaben zahlreiche Vorteile der Zweischichttechnik an.
Die digitale Auswertung der präparierten Zähne konnte unter den Limitationen der vorliegenden Studie keine signifikant schlechtere Präparationsqualität nach zweimaligem Präparieren von einschichtigen Modellzähnen als nach zweimaligem Präparieren von zweischichtigen Übungszähnen nachweisen (p = 0,91).
Der Lernerfolg der Studierenden erwies sich durch in Zweischichttechnik gedruckte Zähne mit integriertem Veneer nicht besser als durch einschichtige Modellzähne (〖ΔL〗_A= -0,01; 〖ΔL〗_B= -0,03). Der Unterschied zwischen den Präparationsergebnissen des ersten und vierten Durchgangs war allerdings nicht signifikant (Gruppe A: Ø GMW+/- 0,17 ± 0,07 → Ø GMW+/- 0,18 ± 0,05, p = 0,317; Gruppe B: Ø GMW+/- 0,15 ± 0,07 → 0,18 ± 0,09, p = 0.066). Gründe hierfür könnten unter anderem Ermüdung und sinkende Motivation während des praktischen Kurses gewesen sein. Diesem Problem könnte Rechnung getragen werden, indem folgende Studien an mehreren Terminen durchgeführt werden. Auch eine mögliche Fokussierung der Studierenden auf das Ablösen der oberen Schicht sowie die unterschiedliche Härte der beiden Schichten könnten einen besseren Lernerfolg mit zweischichtigen Übungszähnen verhindert haben.
Die Teilnehmer, die ihre manuellen Fertigkeiten als besonders gut einschätzen, präparierten mit einer durchschnittlichen mittleren absoluten Abweichung von 0,17 ± 0,07 nicht signifikant besser als die Teilnehmer mit geringer Selbsteinschätzung, welche eine mittlere absolute Abweichung von 0,16 ± 0,05 (p = 0 ,967) erreichten.
71 Studierende nahmen am Universitätsklinikum Würzburg in der Abteilung für Zahnärztliche Prothetik an einem freiwilligen Übungsseminar zum Aufpassen von Kronen mit Störstellen, die im 3D-Druckverfahren hergestellt wurden, teil. Das Übungsseminar fand an zwei Terminen statt. Zum Identifizieren der Störstellen standen Xantopren und Okklusionsspray zur Verfügung. Nach dem praktischen Teil der Übung wurde ein Fragebogen ausgefüllt. Zusätzlich wurden die aufgepassten Kronen mittels Laborscanner digitalisiert und mit einer Krone ohne Störstellen überlagert. Dadurch konnten positive und negative Oberflächenabweichungen für die Bereiche der Störstellen sowie der Gesamtinnenfläche der Kronen ermittelt werden.
Die flächenbezogenen Abweichungswerte zeigten einen signifikanten Lernerfolg – gemessen anhand der Passungsparameter - zwischen den beiden Terminen des Übungsseminars. Hierbei erreichten Kronen, die mit Okklusionsspray aufgepasst wurden, signifikant geringere flächenbezogene Abweichungswerte im Vergleich zu Kronen, die mit Xantopren aufgepasst wurden.
Die Auswertung der mit Schulnoten skalierten Fragen ergab signifikante Unterschiede bei der Bewertung der Härte, eines realitätsnahen Gefühls beim Einschleifen bzw. beim Aufpassen und Details wie Randschluss. Beim Vergleich der Aufpassmethoden im Fragebogen ergaben die Einfachheit beim Aufpassen, das Identifizieren der Störstellen und das präferierte Material signifikante Unterschiede. Der subjektive Lernerfolg mit den Materialien zeigte ebenfalls signifikante Unterschiede. Insbesondere die Materialeigenschaften und die Randgenauigkeit der Druckkronen wurden häufig kritisiert, die schnelle und einfache Möglichkeit zur Herstellung von Übungsmaterialien sowie deren Reproduzierbarkeit wurden von den Studierenden hingegen begrüßt.