Refine
Has Fulltext
- yes (41)
Is part of the Bibliography
- yes (41)
Year of publication
Document Type
- Doctoral Thesis (25)
- Journal article (16)
Keywords
- Gesichtsschmerz (4)
- 3D-Druck (3)
- Bruxismus (3)
- 3D printing (2)
- CAD/CAM (2)
- Craniomandibuläre Dysfunktion (2)
- Doppelkronen (2)
- Elektromyographie (2)
- Kaukraft (2)
- Metaanalyse (2)
Institute
- Poliklinik für Zahnärztliche Prothetik (41) (remove)
Background: That a differentiated treatment of subjects with low and high levels of disabling pain might be necessarily has only been suspected but not sufficiently confirmed so far. Furthermore, the effectiveness of extraoral therapy methods for TMD is still controversial in the literature. The present work could make an important contribution to this.
Objectives: Five systematic reviews with meta-analysis were conducted to investigate the efficacy of extraoral therapies (acupuncture, laser, medication, psychosocial interventions, and physiotherapy) in the treatment of TMD in relation to the degree of chronicity of pain.
Literature sources: With this objective, the databases Pubmed/MEDLINE, EMBASE, Cochrane Library, Livivo, OpenGrey, drks.de, Clinicaltrials.gov. were searched.
Criteria for the selection of suitable studies: Adults suffering from painful TMD and treated with either acupuncture, laser, medication, psychosocial interventions, or physiotherapy. The studies were then examined for evidence in the subjects' characteristics suggesting that they were suffering from chronic TMD in terms of pain dysfunction. These included a high score on the GCPS, resistance to undergone treatments, multilocular pain, depression, and regular use of pain medication. The effectiveness of the five interventions was then differentiated according to the suspected degree of chronicity. Effectiveness was assessed by the following outcomes: patient- related current pain intensity, MMO, pain on palpation, temporomandibular joint sounds, depression, and somatization.
Study evaluation: After the assessment of the studies, the quality assessment (Risk of Bias Tool of the Cochrane Institute) and the extraction of the data were conducted. After that five meta-analyses were carried out for each of the five interventions using the Review Manager of the Cochrane Institute (RevMan 5.3)
Results: Acupuncture and dry needling were statistically significantly more effective in providing short-term pain relief compared to the control group in patients with low disability pain (p=0.04) and (p=0.02), respectively. Acupuncture or dry needling did not show a significant result in the improvement of MMO in the short-term period. Laser therapy is more effective in relieving pain (p<0.0001) and functional outcomes (p=0.03) in the short term compared to placebo for low disability pain. Botulinum toxin (p=0.003) and NSAIDs (p=0.03) showed significantly better short-term improvement in pain intensity for high disability pain. Low disability pain is significantly better treated by psychosocial interventions than by other treatments in terms of long-term pain relief (more than 12 months) (p=0.02). Patients with high disability pain had significantly lower depression scores after psychosocial interventions than after other treatments (p=0.008). Physiotherapy showed a statistically significant short-term analgesic effect in patients with high disability pain compared to placebo (p=0.04). Manual Therapy (MT) showed a statistically significant short-term analgesic effect in high disability pain compared to the control group (p=0.01). Patients with low disability pain showed a statistically significant short-term pain-relieving effect with the single intervention of MT in combination with exercise compared to the control groups (p=0.003). A statistically significant result in the improvement of MMO was found in the short-term period in low disability pain for the single interventions of physiotherapy (p=0.008) and physiotherapy in combination with another treatment compared to other treatments (p=0.03), MT compared to the control group (p=0.03) and physiotherapy compared to splint therapy (p=0.03). Clinical conclusion: Individual interventions of the five extraoral therapies confirm the hypothesis that painful TMDs respond differently to established therapies depending on the degree of chronic pain-related disability and that the prognosis of therapy is significantly influenced by the degree of chronic pain- related disability of the condition, according to the GCPS.
Registration number of the review at PROSPERO: CRD42020202558
Keywords: meta-analysis, systematic review, temporomandibular disorders, extra oral therapy, acupuncture, laser, medication, psychosocial interventions, physiotherapy, low disability, high disability, pain, chronification
Artificial intelligence (AI) has already arrived in many areas of our lives and, because of the increasing availability of computing power, can now be used for complex tasks in medicine and dentistry. This is reflected by an exponential increase in scientific publications aiming to integrate AI into everyday clinical routines. Applications of AI in orthodontics are already manifold and range from the identification of anatomical/pathological structures or reference points in imaging to the support of complex decision-making in orthodontic treatment planning. The aim of this article is to give the reader an overview of the current state of the art regarding applications of AI in orthodontics and to provide a perspective for the use of such AI solutions in clinical routine. For this purpose, we present various use cases for AI in orthodontics, for which research is already available. Considering the current scientific progress, it is not unreasonable to assume that AI will become an integral part of orthodontic diagnostics and treatment planning in the near future. Although AI will equally likely not be able to replace the knowledge and experience of human experts in the not-too-distant future, it probably will be able to support practitioners, thus serving as a quality-assuring component in orthodontic patient care.
71 Studierende nahmen am Universitätsklinikum Würzburg in der Abteilung für Zahnärztliche Prothetik an einem freiwilligen Übungsseminar zum Aufpassen von Kronen mit Störstellen, die im 3D-Druckverfahren hergestellt wurden, teil. Das Übungsseminar fand an zwei Terminen statt. Zum Identifizieren der Störstellen standen Xantopren und Okklusionsspray zur Verfügung. Nach dem praktischen Teil der Übung wurde ein Fragebogen ausgefüllt. Zusätzlich wurden die aufgepassten Kronen mittels Laborscanner digitalisiert und mit einer Krone ohne Störstellen überlagert. Dadurch konnten positive und negative Oberflächenabweichungen für die Bereiche der Störstellen sowie der Gesamtinnenfläche der Kronen ermittelt werden.
Die flächenbezogenen Abweichungswerte zeigten einen signifikanten Lernerfolg – gemessen anhand der Passungsparameter - zwischen den beiden Terminen des Übungsseminars. Hierbei erreichten Kronen, die mit Okklusionsspray aufgepasst wurden, signifikant geringere flächenbezogene Abweichungswerte im Vergleich zu Kronen, die mit Xantopren aufgepasst wurden.
Die Auswertung der mit Schulnoten skalierten Fragen ergab signifikante Unterschiede bei der Bewertung der Härte, eines realitätsnahen Gefühls beim Einschleifen bzw. beim Aufpassen und Details wie Randschluss. Beim Vergleich der Aufpassmethoden im Fragebogen ergaben die Einfachheit beim Aufpassen, das Identifizieren der Störstellen und das präferierte Material signifikante Unterschiede. Der subjektive Lernerfolg mit den Materialien zeigte ebenfalls signifikante Unterschiede. Insbesondere die Materialeigenschaften und die Randgenauigkeit der Druckkronen wurden häufig kritisiert, die schnelle und einfache Möglichkeit zur Herstellung von Übungsmaterialien sowie deren Reproduzierbarkeit wurden von den Studierenden hingegen begrüßt.
Ziel dieser klinisch-experimentellen Studie war die Untersuchung
elektromyographischer Kaumuskelprofile von beschwerdefreien Probandinnen
unterschiedlichen Bruxismusgrades nach sensomotorischem Training. Die aufgestellte
Hypothese postulierte signifikante Unterschiede der EMG-Parameter nach
sensomotorischem Training. Nach einer Ruhephase ohne Intervention sollten die
Unterschiede in den Ausgangszustand zurückkehren. Hierzu wurden 40 Probandinnen
mit einem Durchschnittsalter von 24,58 ± 2,72 Jahren über einen Zeitraum von fünf
Wochen untersucht. Die Probandinnen wurden mittels zufälliger Verteilung und
altersentsprechend gematcht in zwei gleichgroße Gruppen eingeteilt. Sowohl die
Teilnehmerinnen der Kontrollgruppe, als auch die der Interventionsgruppe absolvierten
im Verlauf der Studie drei elektromyographische Messungen. Nach einer einwöchigen
Voruntersuchungsphase fand die erste Messung (T1) statt. Nach drei Wochen und nach
fünf Wochen erfolgten die zweite (T2) und die dritte Messung (T3). Während der
Messungen führten die Probandinnen kraftkontrollierte Übungen mit drei
submaximalen Kraftleveln und maximalen Kräften aus. Zusätzlich absolvierte die
Interventionsgruppe zwischen T1 und T2 ein sensomotorisches Training mit dem
RehaBite®-Gerät. Die bipolaren Oberflächen-EMG-Ableitungen erfolgten für beide Mm.
masseteres und Mm. temporales. Insgesamt wurden acht Muskelareale aufgezeichnet.
Sechs für die Mm. masseteres und zwei für die Mm. temporales. Die submaximalen
Kräfte wurden als RMS %MVC und die maximalen Kräfte als RMS MVC verglichen. Die
statistischen Vergleiche erfolgten anhand von T-Tests und Mixed ANOVAs. Nach
Beurteilung der Ergebnisse konnte kein signifikanter Effekt des sensomotorischen
Trainings identifiziert werden. Die aufgestellte Hypothese muss daher abgelehnt
werden. Für das erste der drei submaximalen Kraftlevel konnte für die Initialmessung
(T1) ein signifikanter Unterschied zwischen Probandinnen mit und ohne Schlafbruxismus
in zwei der acht Muskelareale festgestellt werden. Für zukünftige Folgeuntersuchungen
zur Wirksamkeit des sensomotorischen Trainings bei Bruxismus ist die Verlängerung des
Interventionsintervalls sowie eine Vergrößerung des Studienkollektivs samt Einschluss
männlicher Probanden empfehlenswert.
The main objective of this study was to test whether subjects with different degrees of bruxism differ regarding EMG parameters and whether CES intervention affects those parameters. The hypothesis was that CES influences EMG parameters and after its’ cessation, all EMG parameters return to baseline (exposure–response relationship).
For this purpose, forty subjects were examined, 16 men and 24 women, matched for age and gender and assigned randomly in the intervention (N=20) and control group (N=20). The procedure was as follows: 1-week inactive GC (N=40), 2 weeks inactive/active GC (N=20/N=20), 2 weeks inactive GC (N=40). Each interval was followed by a surface EMG recording from eight muscle parts (right and left anterior -, medial -, and posterior masseter and right and left anterior temporalis) under force-controlled feedback (BiteFork®) with three submaximal bite forces. The resulting EMG activity is expressed as RMS % MVC and RMS at MVC. The statistics is performed with t-test, one-way rmANOVA, and Friedman rmANOVA on ranks, according to the distribution of the data. The significance level was set at p≤0.05.
The results generated from the within-groups and between-groups comparison were mostly not statistically significant and could therefore not offer clinically relevant conclu-sions.
However, it cannot be excluded that a higher submaximal bite force and an extended intervention interval would have rendered different outcomes. The insufficient study sample resulted in a low observed power which makes the findings prone to Type II er-ror. It can be concluded that this study did not find any substantiating differences be-tween the EMG values of participants with various bruxism activity and that CES could not influence the studied EMG parameters in the two weeks intervention time.
Our hypothesis which supposes that subjects with high and low bruxism activity differ in RMS % MVC could not be verified. However, with the gained knowledge, it is recom-mended to further elaborate a definite bruxism diagnosis by using portable EMG devices.
Background: This randomized clinical trial was conducted to assess whether sleep bruxism (SB) is associated with an increased rate of technical complications (ceramic defects) in lithium disilicate (LiDi) or zirconia (Z) molar single crowns (SCs). Methods: Adult patients were classified as affected or unaffected by SB based on structured questionnaires, clinical signs, and overnight portable electromyography (BruxOff) and block randomized into four groups according to SB status and crown material (LiDi or Z): LiDi-SB (n = 29), LiDi-no SB (n = 24), Z-SB (n = 23), and Z-no SB (n = 27). Differences in technical complications (main outcome) and survival and success rates (secondary outcomes) one year after crown cementation were assessed using Fisher’s exact test with significance level α = 0.05. Results: No technical complications occurred. Restoration survival rates were 100% in the LiDi-SB and LiDi-no SB groups, 95.7% in the Z-SB group, and 96.3% in the Z-no SB group (p > 0.999). Success rates were 96.6% in the LiDi-SB group, 95.8% in the LiDi-no SB group (p > 0.999), 91.3% in the Z-SB group, and 96.3% in the Z-no SB group (p ≥ 0.588). Conclusions: With a limited observation time and sample size, no effect of SB on technical complication, survival, and success rates of molar LiDi and Z SCs was detected.
The aim of this randomized, controlled animal exploratory trial was to investigate the influence of local application of aminobisphosphonate pamidronate during the socket preservation procedure. Mandibular premolars were extracted in five Göttingen minipigs. Two animals underwent socket preservation using BEGO OSS (n = 8 sockets) and three animals using BEGO OSS + Pamifos (15 mg) (n = 12 sockets). After jaw impression, cast models (baseline, eight weeks postoperative) were digitized using an inLab X5 scanner (Dentsply Sirona) and the generated STL data were superimposed and analyzed with GOM Inspect 2018 (GOM, Braunschweig). After 16 weeks, the lower jaws were prepared and examined using standard histological methods. In the test group (BEGO OSS + pamidronate), buccooral dimensional loss was significantly lower, both vestibulary (−0.80 ± 0.57 mm vs. −1.92 ± 0.63 mm; p = 0.00298) and lingually (−1.36 ± 0.58 mm vs. −2.56 ± 0.65 mm; p = 0.00104) compared with the control group (BEGO OSS). The test group showed a significant difference between vestibular and lingual dimensional loss (p = 0.04036). Histology showed cortical and cancellous bone in the alveolar sockets without signs of local inflammation. Adjuvant application of pamidronate during socket preservation reduces alveolar dimensional loss significantly. Further investigations with regard to dose–response relationships, volume effects, side effects, and a verification of the suitability in combination with other bone substitute materials (BSMs) are necessary.
Positional plagiocephaly (PP) is the most common skull deformity in infants. Different classification systems exist for graduating the degree of PP, but all of these systems are based on two-dimensional (2D) parameters. This limitation leads to several problems stemming from the fact that 2D parameters are used to classify the three-dimensional (3D) shape of the head. We therefore evaluate existing measurement parameters and validate a newly developed 3D parameter for quantifying PP. Additionally, we present a new classification of PP based on a 3D parameter. 210 patients with PP and 50 patients without PP were included in this study. Existing parameters (2D and 3D) and newly developed volume parameters based on a 3D stereophotogrammetry scan were validated using ROC curves. Additionally, thresholds for the new 3D parameter of a 3D asymmetry index were assessed. The volume parameter 3D asymmetry index quantifies PP equally as well as the gold standard of 30° diagonal difference. Moreover, a 3D asymmetry index allows for a 3D-based classification of PP. The 3D asymmetry index can be used to define the degree of PP. It is easily applicable in stereophotogrammetric datasets and allows for comparability both intra- and inter-individually as well as for scientific analysis.
Objectives
In this in-vitro study, teeth were imaged using photoacoustic tomography (PAT), cone-beam computed tomography (CBCT), and micro-computed tomography (μ-CT). The study had aim: to identify the best wavelength for PAT images to determine the accuracy of the three imaging methods, and to determine whether PAT images of teeth can achieve acceptable reconstruction quality.
Methods
Nineteen human mandibular single-rooted incisors were extracted from patients with trauma or periodontitis. To determine the best wavelength for acquiring photoacoustic images, all 19 teeth were scanned in vitro with PAT, using different laser wavelengths between 680 and 960 nm. The images were analyzed using image analysis software. To assess the accuracy of PAT and compare it with the accuracy of CBCT, each tooth was also scanned in vitro using CBCT and the reference standard technique of μ-CT. Subsequently, three different three-dimensional models, one for each imaging technique, were created for each tooth. Finally, the three different three-dimensional models acquired for the same tooth were matched and analyzed regarding volume and surface.
Results
The highest quality tooth images were achieved using the 680 nm wavelength, which showed the best contrast ratio. The full geometry of the dental root (μ-CT compared with PAT) could be visualized with relative standard deviations of 0.12 mm for the surface and −7.33 mm3 for the volume (n = 19). The full geometry of the dental root (μ-CT compared with CBCT) could be visualized with relative standard deviations of 0.06 mm for the surface and −14.56 mm3 for the volume (n = 19). The difference between the PAT–μ-CT group and CBCT–μ-CT group regarding the total average of the root surface area was not significant (p>0.06).
Conclusion
Images, which were acquired using PAT at 680nm showed the best contrast ration, enabling the identification of dentin, cementum and the dental pulp. No significant differences were found between the PAT–μ-CT group and CBCT–μ-CT group regarding the total average of the RSA and the total volume. Thus, three-dimensional reconstructions based on in-vitro PAT are already of acceptable reconstruction quality.
Medication-related osteonecrosis of the jaw (MRONJ) represents an adverse side effect of antiresorptive and antiangiogenic medications. It is associated with impaired quality of life, oral health, and oral function and can be classified into various stages. The purpose of this prospective clinical study is to evaluate the impact of stages I and II MRONJ on oral-health-related quality of life (OHRQoL) and related parameters. Patients’ OHRQoL, satisfaction with life, oral discomfort, and oral health were assessed using the German version of the Oral Health Impact Profile (OHIP-G49), visual analog scales (VAS), and Satisfaction with Life Scale (SWLS) at baseline (T0), 10 days (T1), and 3 months after treatment (T2) in 36 patients. Data were analyzed using Kolmogorov–Smirnov test, two-way mixed ANOVAs, and follow-up Mann–Whitney U tests. The impact of treatment effects on the original seven OHIP domain structures and the recently introduced four-dimensional OHIP structure were evaluated using linear regression analysis. Thirty-six patients received surgical MRONJ treatment. Before treatment, patients’ perceived OHRQoL, oral discomfort, oral health, and satisfaction with life were negatively affected by MRONJ. Surgical treatment significantly improved OHRQoL and related parameters (all p ≤ 0.012). This improvement was greater in patients with higher impairment at T0. OHRQoL and oral restrictions were still impaired after treatment in patients who needed prosthetic treatment. The four-dimensional structure revealed valuable information beyond the standard seven OHIP domains. Increased awareness of MRONJ risks and an interdisciplinary treatment approach for MRONJ patients are needed.
Im präklinischen Ausbildungsabschnitt des Zahnmedizinstudiums sollen die Studierenden möglichst umfassend und vielseitig auf die Behandlung von Patienten vorbereitet werden. Bislang zählt die Schienung parodontal gelockerter Zähne nicht zum Ausbildungsspektrum und es gibt kein Übungsmodell, mit welchem diese Art der Versorgung erlernt werden könnte. Ziel dieser Studie war es, Zähne für ein Übungsmodell zu entwickeln, dieses mithilfe des 3D-Druckes herzustellen, sowie zusätzlich die Handhabung von verschiedenen Schienungsmaterialien von ungeübten Behandlern bewerten zu lassen.
Es wurden parodontal gelockerte Zähne digital designt und mithilfe eines Stereolithographie 3D-Druckers gedruckt. Insgesamt 43 Studierende des siebten Fachsemesters nahmen im Rahmen des Parodontologiekurses freiwillig an der Studie teil. Es wurden pro Teilnehmer zwei Garnituren Zähne jeweils mit dem Material everStick Perio (GC Dental) und dem Material Ribbond Ultra (Ribbond Inc.) geschient. Die Bewertung der gedruckten Übungszähne sowie der zwei Schienungsmaterialien durch die Teilnehmer erfolgte mithilfe eines Fragebogens unter Nutzung der Schulnoten von 1 (sehr gut) bis 6 (ungenügend). Die geschienten Modelle wurden gescannt und digital verglichen.
Die Schienungsübung wurde insgesamt als „gut“ empfunden. Die Realitätstreue der Zahnlockerungen sowie die Repositionierung der Zähne in den Zahnbogen wurden mit der Note „befriedigend“ bewertet. Das Material everStick Perio bekam in der Handhabung die Note „befriedigend“, das Material Ribbond Ultra die Note „gut“. Der Lerneffekt der Übung wurde mit der Note „gut“ bewertet, wobei die Teilnehmer ihre eigenen Fähigkeiten vor dem Kurs als „mangelhaft“ und nach dem Kurs als „gut“ bewerteten. Die digitale Auswertung der geschienten Modelle ergab keinen signifikanten Unterschied zwischen den einzelnen Gruppen, welche sich nach Schienungsmaterial, Erst- oder Zweitversuch der Schienung sowie den einzelnen geschienten Zähnen aufgliederten.
Die Anwendbarkeit dieses Trainingskonzeptes wurde bestätigt, da sich aus Sicht der Studierenden ein positiver Lerneffekt zeigte.
Restaurationen aus Vollkeramik sind im Fokus der modernen Zahnmedizin. Die
aktuell gängigen Keramiken sind Lithiumdisilikatkeramik (=LiSi2), eine Glaskeramik
mit eingelagerten Silikatkristallen und Zirkoniumdioxidkeramik (=ZrO2), eine
Oxidkeramik. Erstere zeichnet sich durch exzellente optische und letztere durch
hervorragende mechanische Eigenschaften aus.
In der vorliegenden Studie wurde der Einfluss der Schichtdicke der beiden
Keramiken, des künstlichen Alterungsprozesses und der Substruktur, auf die die
Keramik verklebt wurde, untersucht.
Insgesamt wurden 256 Proben nach einem standardisierten Verfahren hergestellt: 64
reine Materialproben und 192 Echtzahnkeramikproben. Von den Zahnproben
durchlief die Hälfte einen Alterungsprozess.
Sechs der LiSi2 und zwei der ZrO2 Echtzahnkeramikproben brachen bereits beim
Alterungsprozess. Die höchsten Bruchlastwerte bei den Keramikechtzahnproben
erzielte ZrO2 (2420 N) und LiSi2 (1.783 N) in einer Schichtdicke von 2 mm jeweils
ohne Alterung. Die zu Bruch gegangenen außer Acht gelassen, entstanden die
niedrigsten Werte bei den dünnen Keramikproben ohne Zahnanteil in 0,5 mm
Schichtdicke (140 N ZrO2 Vgl. 99 N LiSi2).
Außerdem veranschaulichen die Ergebnisse, dass die Keramikproben mit
Schmelzanteil signifikant höhere Bruchlastwerte (p< 0,002) erzielten, als ihre
Vergleichspartner mit mehr Dentinanteil. Zudem zeigt sich, dass
Zirkoniumdioxidkeramik höhere Bruchlastwerte erreichte als Lithiumdisilikatkeramik,
sowohl nach dem Alterungsprozess, als auch bei sehr dünner Schichtstärke.
Im Vergleich zur aktuellen Literatur fällt auf, dass es bisher wenige standarisierte
Verfahren zur Herstellung von Keramikechtzahnproben gibt.
Andere, aber dennoch vergleichbare Studien, kommen zu ähnlichen Ergebnissen:
Scheinbar hat der Zahnschmelz einen unterstützenden Effekt auf die
Keramikechtzahnprobe. Der Einfluss des Alterungsprozesses bei den Proben darf
nicht unterschätzt werden und die Schichtdicke der Keramik wirkt sich auf das
Bruchlastverhalten der Probenkörper aus.
In der Simulation einer möglichst realitätsnahen Situation der Mundhöhle gilt es viele
Variablen wie etwa Lagerung der Proben, Schleifrichtung der Zahnhartsubstanz,
Verklebung der Proben und Belastung im Kausimulator zu beachten.
Background
Passive mandibular advancement with functional appliances is commonly used to treat juvenile patients with mandibular retrognathism.
Objective
The aim of this study was to investigate whether active repetitive training of the mandible into an anterior position would result in a shift of the habitual mandibular position (HMP).
Methods
Twenty adult healthy subjects were randomly assigned to one of two groups: a training group receiving six supervised functional training sessions of 10 min each and a control group without training. Bonded lateral biteplates disengaged occlusion among both groups throughout the 15‐day experiment. Customised registration‐training appliances consisted of a maxillary component with an anterior plane and a mandibular component with an attached metal sphere. Training sessions consisted of repeated mouth‐opening/closing cycles (frequency: 30/min) to hit an anteriorly positioned hemispherical target notch with this metal sphere. The HMP was registered at defined times during the experiment.
Results
The HMP in the training group showed a statistically significant anterior shift of 1.6 mm (interquartile range [IQR]: 1.2 mm), compared with a significant posterior shift of −0.8 mm (IQR: 2.8 mm) in the control group (p < .05). Although the anterior shift among the training group showed a partial relapse 4 days after the first training block, it then advanced slightly in the 4‐day interval after the second training block, which might indicate neuroplasticity of the masticatory motor system.
Conclusions
Motor learning by repetitive training of the mandible into an anterior position might help to improve the results of functional appliance therapy among patients with mandibular retrognathism.
Background
The influence of the stomatognatic system on human posture control has been investigated under static conditions, but the effects on dynamic balance have not yet been considered.
Objective
Investigating the influence of different functional stomatognatic activities (jaw clenching (JAW), tongue pressing (TON) and habitual jaw position (HAB)) on postural performance during a dynamic reactive balance task.
Methods
Forty‐eight physically active and healthy adults were assigned to three groups differing in oral‐motor tasks (JAW, TON or HAB). Dynamic reactive balance was assessed by an oscillating platform which was externally perturbed in four directions. Performance was quantified by means of Lehr's damping ratio. Mean speeds of the selected anatomical regions (head, trunk, pelvis, knee and foot) were analysed to determine significant performance differences.
Results
The groups differed significantly in balance performance in direction F (i.e., forwards acceleration of the platform). Post hoc tests revealed that the JAW group had significantly better performance compared with both the HAB and TON groups. Better performance was associated with a decreased mean speed of the analysed anatomical regions.
Conclusion
JAW can improve dynamic reactive balance but the occurrence of positive effects seems to be task‐specific and not general. TON seems not to have any observable effects on dynamic reactive balance performance, at least when evaluating it with an oscillating platform. JAW might be a valuable strategy which could possibly reduce the risk of falls in elderly people; however, further investigations are still needed.
Ziel der vorliegenden Arbeit war die Beschreibung der mechanischen Kennwerte im Zusammenhang mit verschiedenen Schichten von Multilayer-Zirkoniumdioxidkeramiken für die frästechnische Herstellung. Untersucht wurden vier Schichten einer jeden geprüften Keramik. Die Dichte, die biaxiale Biegefestigkeit und die Vickers-Härte wurden getestet. Eine Hälfte der Proben (n=30) wurde einer künstlichen Alterung im Thermocycler (10.000 Zyklen, 5°/55°) unterzogen, während die andere Hälfte (n=30) ohne den Einfluss künstlicher Alterung geprüft wurde. Zudem wurde an jedem Material eine EDX-Analyse durchgeführt. Ermittelt wurden die mechanischen Kennwerte der Multilayer-Zirkoniumdioxidkermamiken IPS E.max ZirCAD Prime (Ivoclar Vivadent AG; Schaan, Liechtenstein), Optimill Multilayer 3D (Dentona AG; Dortmund, Deutschland) und Ceramill Zolid fx multilayer (Amann Girrbach GmbH; Koblach, Österreich). Die Dichtewerte veränderten sich bei allen drei Materialien leicht über die Schichten hinweg. Bei den IPS-Proben zeigte sich ein Zusammenhang zwischen der biaxiale Biegefestigkeit und der Schichtung. Für die Härte gab es keine eindeutigen Rückschlüsse auf einen Zusammenhang mit der Transluzenz. Die Dentona- und die Ceramill-Proben zeigten keine an- oder absteigende Tendenz der biaxialen Biegefestigkeit über die Schichten hinweg. Insgesamt zeigten sich signifikante Unterschiede zwischen den mechanischen Kennwerten der unterschiedlichen Multilayer-Zirkoniumdioxidkeramiken (p<0,001). Aus diesem Grund sollte jedes dieser Materialien individuell und mit Bedacht eingesetzt werden.
Die Versorgung von Zahnhartsubstanzdefekten mittels indirekter Restaurationen über Befestigungszemente gehört in Zahnarztpraxen zur alltäglichen Arbeit. Eine stetige Weiterentwicklung der techniksensitiven adhäsiven Befestigungssysteme ergibt eine Bandbreite an unterschiedlichen Befestigungssystemen auf dem Dentalmarkt. Ziel dieser In vitro Studie ist es deshalb, die Haftfestigkeit von adhäsiven, selbstadhäsiven und konventionellen Befestigungssystemen zu indirekten Restaurationsmaterialien sowie Echtzähnen (Dentin), mit und ohne künstliche Alterung, zu überprüfen. Die Haftfestigkeit wurde mithilfe eines Scherfestigkeitstests nach DIN EN ISO 29022:2013 überprüft. Es wurden die Befestigungsmaterialien Panavia™ SA Universal, Visalys® CemCore, G-Cem LinkForce™, Bifix® SE, als Kontrollgruppe Panavia™ V5 und Ketac™ Cem Plus zu den Restaurationsmaterialien Ceramill® zolid ht+ PS (Zirkoniumdioxidkeramik), Enamic® (Hybridkeramik), IPS e.max® CAD (Lithiumdisilikat-Glaskeramik) und Dentin untersucht. Bei den selbstadhäsiven Befestigungszementen Panavia™ SA und Bifix® SE wurden zusätzlich zwei Gruppen zu Dentin mit Konditionierung getestet. Die Befestigungszemente wurden zylinderförmig auf die Restaurationsmaterialien aufgebracht und ausgehärtet. Die Proben mit Alterung wurden zusätzlich für 10.000 Zyklen in einem Thermocycler bei 5°C/55°C gealtert, anschließend wurden alle Proben abgeschert. Die Bruchart wurde in adhäsiver, kohäsiver und gemischter Bruch eingeteilt. Die Ergebnisse belegen zwischen den getesteten Restaurationsmaterialien und Befestigungszementen Unterschiede. Thermocycling hat einen negativen Einfluss auf die Haftfestigkeit. Generell zeigten die Befestigungsmaterialien geringere Haftwerte zu Dentin als zu den Restaurationsmaterialien. Durch zusätzliche Vorbehandlung des Dentins bei Bifix® SE konnten ähnlich hohe Haftfestigkeiten wie zu den Restaurationsmaterialien gemessen werden. Panavia™ V5 zeigte als Kontrollgruppe zu allen Materialien konstante Haftwerte.
Locator\(^®\) and ball attachments are well-established systems to attach overdentures to two inter-foraminal implants. This study aimed to evaluate differences between the two systems regarding prosthetic maintenance and patients’ oral-health-related quality of life (OHRQoL). Dental records of patients with a mandibular implant-retained overdenture were retrospectively analyzed. Prosthetic maintenance measures involving the denture suprastructure and attachment matrix and patrix were analyzed. Furthermore, the Oral Health Impact Profile-G14 (OHIP-G14) was used to evaluate OHRQoL. Results were analyzed by means of Kaplan–Meier analysis and Student’s t- and log-rank tests. The records of 122 patients were evaluated. Kaplan–Meier survival analysis revealed a significant difference between ball attachments (Group B; n patients = 47) and Locator\(^®\) attachments (Group L; n patients = 75) regarding the occurrence of denture fractures (p < 0.001) and events affecting the matrix (p = 0.028) and patrix (p = 0.030). Group L had a significantly lower total OHIP-G14 score than Group B (p = 0.002). The most common maintenance events were matrix-related and denture relining for both attachment systems. Group B required more maintenance measures than Group L. Moreover, patients in Group L had better OHRQoL than patients in Group B.
The aim of this study was to identify correlations between sleep bruxism (SB) and temporomandibular disorders (TMD) as diagnosed by means of the research diagnostic criteria for temporomandibular disorders (RDC/TMD). Sleep bruxism was diagnosed on the basis of I) validated questionnaires, II) clinical symptoms, and III) electromyographic/electrocardiographic data. A total of 110 subjects were included in the study. Fifty-eight patients were identified as bruxers and 52 as nonbruxers. A psychosocial assessment was also performed. An RDC/TMD group-I diagnosis (myofascial pain) was made for 10 out of 58 bruxers, whereas none of the nonbruxers received a diagnosis of this type. No significant differences were found between bruxers and nonbruxers with regard to RDC/TMD group-II (disc displacement) and group-III (arthralgia, arthritis, arthrosis) diagnoses. Somatization was significantly more common among bruxers than nonbruxers. Multivariate logistic regression analysis revealed that somatization was the only factor significantly correlated with the diagnosis of myofascial pain. The results of this study indicate a correlation between myofascial pain, as diagnosed using the RDC/TMD, and somatization. It seems that somatization is a stronger predictor of an RDC/TMD diagnosis of myofascial pain than sleep bruxism is.
EMG, Kaukraft und Unterkieferkinematik beim unilateralen Kauen elastischer und spröder Testnahrung
(2022)
Ziel dieser Arbeit war die synchrone Aufzeichnung der EMG-Aktivität aller Kaumuskeln bilateral, zusammen mit der Unterkieferkinematik und der Kaukraft beim Kauen von elastischer und spröder Testnahrung.
Vierzehn gesunde Erwachsene nahmen erfolgreich an der experimentellen Studie teil, nachdem sie ihr schriftliches Einverständnis gegeben hatten. Das Studienprotokoll wurde von der Ethikkommission der Medizinischen Fakultät der Universität Würzburg genehmigt (Nr.: 132/16_z-mk). Alle Verfahren wurden gemäß der Deklaration von Helsinki durchgeführt.
Intraorale Kraftmessgeräte wurden verwendet, um die Kräfte zu messen und zu kontrollieren, die bei der dynamischen Belastung des Kausystems auftreten, wobei das einseitige Zerkauen von zwei verschiedenen Testnahrungsmitteln simuliert wurde. Die EMG-Signale und das bilaterale EMG-Kokontraktionsmuster aller Kaumuskeln wurden bilateral mittels Oberflächen- und intramuskulärer Elektroden aufgezeichnet. Die Unterkieferkinematik wurde mit einem magnetischen Kinesiographen aufgezeichnet. Die dabei gewonnenen Daten dienten der Entwicklung und Validierung eines numerischen Finite-Elemente-Modells (FEM) mit dem Ziel, die Okklusion künstlicher Kauflächen zu optimieren.
Die Ergebnisse anderer Studien bezüglich der Unterschiede zwischen den Kauseiten, den Geschlechtern und der Kauaktivität sowie der Härte der Lebensmittel stimmen weitgehend mit unseren Ergebnissen überein.
Erstmals wurden diese experimentellen Ergebnisse durch eine Studie verifiziert, die alle relevanten Parameter sequentiell und synchron auswertete. Dieser experimentelle Ansatz ermöglicht es, FEM-Simulationen mit dynamischen Daten des komplexen Kauzyklus zu validieren.
Simulation der Kariesentfernung an 3D-gedruckten Molaren: Analyse der Reliabilität und der Validität
(2022)
In der vorliegenden Studie wurde an 50 3D-gedruckten Molaren mit einer konstruierten Referenzkaries das Ausmaß der vollständigen Kariesentfernung flächenabhängig überprüft. Die untersuchten Zähne wurden mit einer simulierten, standardisierten und mehrflächigen Karies versehen. Studierende der Zahnmedizin haben die Karies entfernt, die Kavität mit einer Aufbaufüllung versorgt und die Zähne für eine Vollkrone präpariert. Um die Kariesentfernung zu bewerten, wurden DVT-Aufnahmen und dreidimensionale Scans angefertigt. Aus den DVT-Datensätzen im DICOM-Format wurden die Aufbaufüllungen der Zähne mithilfe digitaler Bildverarbeitung segmentiert und als eigenständige 3D-Modelle dargestellt. Anschließend erfolgte die Überlagerung der Aufbaufüllungen auf den Referenzzahn aus der Konstruktionsdatei der Zähne. Mit der Konstruktionssoftware Autodesk Fusion 360 wurden die Aufbaufüllungen in Volumenkörper umgewandelt und mit der Karies des Referenzzahnes verglichen. Da sich die Aufbaufüllungen mit der Referenzkaries überschneiden, konnte die Software mit ihrer Teilungsfunktion nicht überschneidende Teile separieren. Abhängig von der Lage der Kavität, in der sich die überschüssigen Volumenkörper befanden, wurden jene als Restkaries oder überexkavierte Zahnhartsubstanz identifiziert. Die gemessenen Volumina von Restkaries ergaben, dass an der distalen Zahnfläche im Vergleich zur bukkalen und okklusalen signifikant mehr Karies verblieben war. Ein weiterer signifikanter Unterschied konnte zwischen mesial und bukkal, jedoch nicht zwischen mesial und okklusal festgestellt werden. Bei der Überexkavation gab es zwischen den Zahnflächen keine Unterschiede. Die Ergebnisse zeigten, dass die Kariesentfernung an den approximalen Zahnflächen für die Studierenden eine höhere manuelle Herausforderung darstellte. Neben der volumetrischen Vermessung ermöglichte die dreidimensionale Visualisierung von Restkaries und der überexkavierten Zahnhartsubstanz eine objektive Bewertung des Behandlungsergebnisses für die Studierenden und deren Ausbilder. Besonders der Vergleich mit einer Referenz schaffte eine valide und nachvollziehbare Beurteilung der Kariesübung an 3D-gedruckten Zähnen.