Background:
There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT.
Methods:
Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted.
Results:
Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23–27 mm vs. 23 mm; IQR 21–25; p = 0.009).
Conclusions:
Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.
Background
Right ventricular dysfunction after CABG is associated with poor peri- and postoperative outcomes. We aimed to identify clinical and experimental predictors for preoperative inapparent right ventricular dysfunction and therefore hypothesized that reduced myofilament force development as well as altered levels of biomarkers might predict inapparent right ventricular dysfunction.
Methods
From 08/2016 to 02/2018, 218 patients scheduled for CABG were divided into two groups (TAPSE ≥ 20 mm, n = 178; TAPSE < 20 mm, n = 40). Baseline serum samples for biomarkers (Galectin, TGFß1, N Acyl-SDMA, Arginine, ADMA and Pentraxin-3), clinical laboratory and transthoracic echocardiographic parameters were evaluated. To examine the myocardial apparatus of the right ventricle intraoperative right auricular tissue was harvested for stepwise skinned fiber force measurements.
Results
Patients with TAPSE < 20 mm had a higher incidence of DM (55 vs. 34%, p = 0.018), preoperative AFib (43 vs. 16%, p < 0.001), reduced GFR (67 ± 18 vs. 77 ± 24 ml/min/1.73 m\(^2\), p = 0.013), larger LA area (22 ± 6 vs. 20 ± 5 cm\(^2\), p = 0.005) and reduced LVEF (50 vs. 55%, p = 0.008). Furthermore, higher serum ADMA (0.70 ± 0.13 vs. 0.65 ± 0.15 µmol/l, p = 0.046) and higher serum Pentraxin-3 levels (3371 ± 1068 vs. 2681 ± 1353 pg/dl, p = 0.004) were observed in these patients. Skinned fiber force measurements showed significant lower values at almost every step of calcium concentration (pCa 4.52 to pCa 5.5, p < 0.01 and pCa 5.75–6.0, p < 0.05). Multivariable analysis revealed DM (OR 2.53, CI 1.12–5.73, Euro Score II (OR 1.34, CI 1.02–1.78), preoperative AF (OR 4.86, CI 2.06–11.47), GFR (OR 7.72, CI 1.87–31.96), albumin (OR 1.56, CI 0.52–2.60), Pentraxin-3 (OR 19.68, CI 14.13–25.24), depressed LVEF (OR 8.61, CI 6.37–10.86), lower force values: (pCa 5.4; OR 2.34, CI 0.40–4.29 and pCa 5.2; OR 2.00, CI 0.39–3.60) as predictors for clinical inapparent right heart dysfunction.
Conclusions
These preliminary data showed that inapparent right heart dysfunction in CAD is already associated with reduced force development of the contractile apparatus.