Refine
Has Fulltext
- yes (65) (remove)
Is part of the Bibliography
- yes (65)
Year of publication
Document Type
- Journal article (65) (remove)
Language
- English (65)
Keywords
- PET (13)
- theranostics (13)
- prostate cancer (11)
- CXCR4 (10)
- positron emission tomography (10)
- PET/CT (9)
- multiple myeloma (8)
- radioligand therapy (8)
- PRRT (7)
- PSMA (7)
- Positronen-Emissions-Tomografie (7)
- neuroendocrine tumor (7)
- molecular imaging (5)
- FDG (3)
- NET (3)
- adrenocortical carcinoma (3)
- chemokine receptor (3)
- endoradiotherapy (3)
- medicine (3)
- peptide receptor radionuclide therapy (3)
- somatostatin receptor (3)
- 18F-FDG PET/CT (2)
- C-X-C motif chemokine receptor 4 (2)
- MAG3 (2)
- PSMA I&T (2)
- Parkinson’s disease (2)
- Prostate Cancer (2)
- RADS (2)
- SPECT (2)
- SSTR (2)
- SUV (2)
- [68Ga]PentixaFor (2)
- bone disease (2)
- fibroblast activation protein (2)
- lymphoma (2)
- personalized medicine (2)
- prostate-specific membrane antigen (2)
- prostate-specific membrane antigen (PSMA) (2)
- radionuclide therapy (2)
- salvage radiotherapy (2)
- 11C-Methionine PET/CT (1)
- 123I-Ioflupane (1)
- 177Lu (1)
- 18-F-fluorothymidine uptake (1)
- 18F-DCFPL (1)
- 18F-DCFPyL (1)
- 18F-FDG (1)
- 2-deoxy-2-(18F)fluoro-D-glucose (1)
- 68Ga-Pentixafor PET/CT (1)
- <sup>18</sup>F-FDG (1)
- <sup>68</sup>Ga-Pentixafor (1)
- Arginine (1)
- COVID-19 (1)
- CTCAE (1)
- CXCR4-targeting (1)
- CXCR4/SDF-1 (1)
- CYP11B enzymes (1)
- DLBCL (1)
- DNA repair (1)
- DOTA-EB-TATE (1)
- DOTATOC (1)
- DSB damage (1)
- DaTscan (1)
- FDG PET/CT (1)
- FDG-PET (1)
- FLT-PET (1)
- GCA (1)
- GPR54 (1)
- Ganglia (1)
- HMDP hydroxymethylene diphosphonate (1)
- Hyperkalaemia (1)
- IBA-1 (1)
- IMAZA (1)
- Imaging pitfalls (1)
- KISS1 receptor (1)
- KISS1-54 (1)
- Lysine (1)
- MRI (1)
- Merkel cell carcinoma (1)
- Molecular imaging (1)
- Myocardial-perfusion SPECT (1)
- NEC (1)
- NVP-BGT226 (1)
- PMR (1)
- PSA (1)
- PSA response (1)
- PSMA PET/CT (1)
- PSMA-617 (1)
- PSMA-PET (1)
- PSMA-RADS (1)
- PSMA-TV (1)
- PSMA‐617 (1)
- Parkinsonism (1)
- Pentixafor (1)
- Pitfall (1)
- Positron Emission Tomography (1)
- Positron emission tomography (1)
- Prostata (1)
- RLT (1)
- Radiofluorine (1)
- Radiotracer (1)
- SARS-CoV-2 (1)
- SPECT/CT (1)
- SSTR-PET (1)
- SSTR-RADS (1)
- Single-Photon-Emissions-Computertomographie (1)
- Somatostatin receptor expression (1)
- TBI (1)
- TKI (1)
- TSPO (1)
- Tracer (1)
- Virchow Node (1)
- [177Lu]-DOTATATE/-DOTATOC (1)
- [177Lu]/[90Y]PentixaTher (1)
- [177Lu]Lu-PSMA I&T (1)
- [177Lu]PentixaTher (1)
- [18F]FDG PET/CT (1)
- [18F]Fluorodeoxythymidine (1)
- [68Ga] (1)
- [68Ga]DOTATOC (1)
- [68Ga]Pentixafor (1)
- [90Y]PentixaTher (1)
- [\(^{68}\)Ga] pentixafor (1)
- [\(^{68}\)Ga]Ga-FAPI (1)
- [\(^{68}\)Ga]Pentixafor (1)
- [\(^{68}\)]KISS1-54 (1)
- \(^{11}\)C-Methionine-PET (1)
- \(^{11}\)C-methionine (1)
- \(^{177}\)Lu (1)
- \(^{18}\)F (1)
- \(^{18}\)F-FDG PET/CT (1)
- \(^{18}\)F-PSMA-1007 (1)
- \(^{68}\)Ga (1)
- \(^{68}\)Ga-Pentixafor (1)
- adrenal incidentaloma (1)
- agreement (1)
- amino acids (1)
- attention deficit/hyperactivity disorder (ADHD) (1)
- autologous transplantation (1)
- autoradiography (1)
- biokinetics (1)
- biomarker (1)
- bone-marrow (1)
- cancer (1)
- cancer treatment (1)
- caudate nucleus (1)
- cells (1)
- chemokine receptor-4 (1)
- cholinergic activity (1)
- combination (1)
- comparability (1)
- diffuse (1)
- dopamine transporter (DAT) (1)
- early response (1)
- ejection fraction (1)
- esophagogastric junction (1)
- evans blue (1)
- experience (1)
- flare phenomenon (1)
- focal (1)
- follicular lymphoma (1)
- giant cell arteritis (1)
- glioblastoma (1)
- glioblastoma multiforme (1)
- glioma (1)
- head and neck cancer (1)
- health care (1)
- hematotoxicity (1)
- human tumor cell lines (1)
- hyperkalemia (1)
- imaging (1)
- imaging proliferation (1)
- imaging techniques (1)
- immunohistochemistry (1)
- immunostaining (1)
- in vivo imaging (1)
- in-vivo (1)
- inflammation (1)
- inhibition (1)
- intraindividual comparison (1)
- involvement (1)
- irradiation (1)
- isotopes (1)
- kidney function (1)
- kisspeptin (1)
- late response (1)
- left-ventricular function (1)
- levodopa-induced dyskinesia (1)
- macrophages (1)
- macroscopic recurrence (1)
- magnetic resonance imaging (1)
- malignancies (1)
- mammalian target of rapamycin (1)
- management (1)
- matched pair (1)
- medullary thyroid carcinoma (1)
- metabolic tumor volume (MTV) (1)
- metabolic tumour volume (MTV) (1)
- methionine (1)
- methylphenidate (1)
- microenvironment (1)
- microglial cells (1)
- mouse (1)
- nephrotoxicity (1)
- neuroinflammation (1)
- non-Hodgkin's lymphoma (1)
- non-hodgkins-lymphoma (1)
- ollimator (1)
- overall survival (1)
- pancreas (1)
- papillary thyroid carcinoma (PTC) (1)
- pattern (1)
- peptide receptor (1)
- phosphatidylinositol-3-kinase (1)
- photons (1)
- pleural mesothelioma (1)
- polymyalgia rheumatica (1)
- positron emission tomography/computed tomography (1)
- post-reconstruction filtering (1)
- prediction (1)
- progression (1)
- quality (1)
- quantification (1)
- radiogenomics (1)
- radioiodine (1)
- recurrence (1)
- relapse (1)
- renal scintigraphy (1)
- repair (1)
- reporting and data system (1)
- reporting and data systems (1)
- responsivity (1)
- sarcoidosis (1)
- scanner (1)
- selpercatinib (1)
- signal to noise ratio (1)
- signaling pathway (1)
- simultaneous integrated boost (1)
- single photon emission computed tomography (SPECT) (1)
- skeletal (1)
- small animal SPECT (1)
- small-animal imaging (1)
- smoldering myeloma (1)
- software (1)
- solid tumors (1)
- somatostatin (1)
- somatostatin receptor (SSTR) (1)
- somatostatin receptors (1)
- staging (1)
- standardization (1)
- standardized reporting system (1)
- stem-cell transplantation (1)
- striatum (1)
- super ultraviolet (1)
- survival (1)
- target (1)
- taxane (1)
- thyroid carcinoma (TC) (1)
- thyroid carcinomas (1)
- total lesion PSMA (1)
- total lesion glycolysis (TLG) (1)
- total lesion methionine uptake (TLMU) (1)
- treatment response (1)
- tumor (1)
- tumor heterogeneity (1)
- tyrosine kinase inhibitor (1)
- vandetanib (1)
- vasculature (1)
- vasculitis (1)
- vestibular schwannoma (1)
- weight drop (1)
- α-Particle (1)
- γ-H2AX (1)
Institute
- Klinik und Poliklinik für Nuklearmedizin (65) (remove)
Sonstige beteiligte Institutionen
Utilizing 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT), we performed this pilot study to evaluate the link between cytogenetic/genomic markers and imaging patterns in relapsed/refractory (RR) multiple myeloma (MM). We retrospectively analyzed data of 24 patients with RRMM who were treated at our institution between November 2018 and February 2020. At the last relapse/progression, patients had been treated with a median of three (range 1–10) lines of therapy. Six (25%) patients showed FDG avid extramedullary disease without adjacency to bone. We observed significantly higher maximum standardized uptake values (SUV\(_{max}\)) in patients harboring del(17p) compared with those without del(17p) (p = 0.025). Moreover, a high SUV\(_{max}\) of >15 indicated significantly shortened progression-free survival (PFS) (p = 0.01) and overall survival (OS) (p = 0.0002). One female patient exhibited biallelic TP53 alteration, i.e., deletion and mutation, in whom an extremely high SUV\(_{max}\) of 37.88 was observed. In summary, this pilot study suggested a link between del(17p)/TP53 alteration and high SUV\(_{max}\) on 18F-FDG PET/CT in RRMM patients. Further investigations are highly warranted at this point.
Sarcoidosis is a multisystem granulomatous disorder of unknown etiology that can involve virtually all organ systems. Whereas most patients present without symptoms, progressive and disabling organ failure can occur in up to 10% of subjects. Somatostatin receptor (SSTR)-directed peptide receptor radionuclide therapy (PRRT) has recently received market authorization for treatment of SSTR-positive neuroendocrine tumors.
Methods:
We describe the first case series comprising two patients with refractory multi-organ involvement of sarcoidosis who received 4 cycles of PRRT.
Results:
PRRT was well-tolerated without any acute adverse effects. No relevant toxicities could be recorded during follow-up. Therapy resulted in partial response accompanied by a pronounced reduction in pain (patient #1) and stable disease regarding morphology as well as disease activity (patient #2), respectively.
Conclusion:
Peptide receptor radionuclide therapy in sarcoidosis is feasible and might be a new valuable tool in patients with otherwise treatment-refractory disease. Given the long experience with and good tolerability of PRRT, further evaluation of this new treatment option for otherwise treatment-refractory sarcoidosis in larger patient cohorts is warranted.
Background
Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT\(^+\)).
Methods
The new U-SPECT5-E with two stationary detectors was used for acquiring data with \(^{99m}\)Tc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT\(^+\) for comparison.
Results
Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT\(^+\). In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT\(^+\)) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR.
Conclusions
While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.
We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.
Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7% radiochemical yield and at a >99% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6–4.4% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.