Refine
Has Fulltext
- yes (72)
Is part of the Bibliography
- yes (72)
Year of publication
Document Type
- Journal article (65)
- Preprint (4)
- Conference Proceeding (3)
Language
- English (72)
Keywords
- PET (17)
- prostate cancer (13)
- theranostics (13)
- positron emission tomography (11)
- CXCR4 (10)
- PET/CT (10)
- Positronen-Emissions-Tomografie (10)
- PSMA (9)
- multiple myeloma (8)
- neuroendocrine tumor (8)
- radioligand therapy (8)
- PRRT (7)
- molecular imaging (7)
- RADS (4)
- SPECT (4)
- SSTR (4)
- somatostatin receptor (4)
- 18F-DCFPyL (3)
- DaTscan (3)
- FDG (3)
- NET (3)
- PSMA-RADS (3)
- Prostate Cancer (3)
- adrenocortical carcinoma (3)
- chemokine receptor (3)
- endoradiotherapy (3)
- medicine (3)
- peptide receptor radionuclide therapy (3)
- prostate-specific membrane antigen (3)
- 18F-FDG (2)
- 18F-FDG PET/CT (2)
- C-X-C motif chemokine receptor 4 (2)
- Ioflupane (2)
- MAG3 (2)
- PSMA I&T (2)
- PSMA-PET (2)
- Parkinson (2)
- Parkinson Disease (2)
- Parkinson-Krankheit (2)
- Parkinson’s disease (2)
- Positron Emission Tomography (2)
- SSTR-RADS (2)
- SUV (2)
- TKI (2)
- Virchow Node (2)
- [177Lu]-DOTATATE/-DOTATOC (2)
- [68Ga] (2)
- [68Ga]PentixaFor (2)
- bone disease (2)
- fibroblast activation protein (2)
- lymphoma (2)
- personalized medicine (2)
- prostate-specific membrane antigen (PSMA) (2)
- radionuclide therapy (2)
- reporting and data system (2)
- salvage radiotherapy (2)
- tumor heterogeneity (2)
- vandetanib (2)
- 11C-Methionine PET/CT (1)
- 123I-Ioflupane (1)
- 177Lu (1)
- 18-F-fluorothymidine uptake (1)
- 18F-DCFPL (1)
- 2-deoxy-2-(18F)fluoro-D-glucose (1)
- 68Ga-DOTANOC (1)
- 68Ga-DOTATATE (1)
- 68Ga-DOTATOC (1)
- 68Ga-Pentixafor PET/CT (1)
- <sup>18</sup>F-FDG (1)
- <sup>68</sup>Ga-Pentixafor (1)
- Arginine (1)
- COVID-19 (1)
- CTCAE (1)
- CXCR4-targeting (1)
- CXCR4/SDF-1 (1)
- CYP11B enzymes (1)
- DLBCL (1)
- DNA repair (1)
- DOTA-EB-TATE (1)
- DOTATOC (1)
- DSB damage (1)
- FDG PET/CT (1)
- FDG-PET (1)
- FLT-PET (1)
- GCA (1)
- GPR54 (1)
- Ganglia (1)
- HMDP hydroxymethylene diphosphonate (1)
- Hyperkalaemia (1)
- IBA-1 (1)
- IMAZA (1)
- Imaging pitfalls (1)
- KISS1 receptor (1)
- KISS1-54 (1)
- Lysine (1)
- MI-RADS (1)
- MRI (1)
- Merkel cell carcinoma (1)
- Molecular imaging (1)
- Myocardial-perfusion SPECT (1)
- NEC (1)
- NVP-BGT226 (1)
- PMR (1)
- PROMISE (1)
- PSA (1)
- PSA response (1)
- PSMA PET/CT (1)
- PSMA-617 (1)
- PSMA-TV (1)
- PSMA‐617 (1)
- Pancreas (1)
- Parkinsonism (1)
- Pentixafor (1)
- Pitfall (1)
- Positron emission tomography (1)
- Prostata (1)
- RLT (1)
- Radiofluorine (1)
- Radiotracer (1)
- SARS-CoV-2 (1)
- SPECT/CT (1)
- SSTR-PET (1)
- Single-Photon-Emissions-Computertomographie (1)
- Somatostatin receptor expression (1)
- TBI (1)
- TSPO (1)
- Tracer (1)
- [177Lu]/[90Y]PentixaTher (1)
- [177Lu]Lu-PSMA I&T (1)
- [177Lu]PentixaTher (1)
- [18F]FDG PET/CT (1)
- [18F]Fluorodeoxythymidine (1)
- [68Ga]DOTATOC (1)
- [68Ga]Pentixafor (1)
- [90Y]PentixaTher (1)
- [\(^{68}\)Ga] pentixafor (1)
- [\(^{68}\)Ga]Ga-FAPI (1)
- [\(^{68}\)Ga]Pentixafor (1)
- [\(^{68}\)]KISS1-54 (1)
- \(^{11}\)C-Methionine-PET (1)
- \(^{11}\)C-methionine (1)
- \(^{177}\)Lu (1)
- \(^{18}\)F (1)
- \(^{18}\)F-FDG PET/CT (1)
- \(^{18}\)F-PSMA-1007 (1)
- \(^{68}\)Ga (1)
- \(^{68}\)Ga-Pentixafor (1)
- adrenal incidentaloma (1)
- ageing (1)
- agreement (1)
- amino acids (1)
- attention deficit/hyperactivity disorder (ADHD) (1)
- autologous transplantation (1)
- autoradiography (1)
- biokinetics (1)
- biomarker (1)
- bone-marrow (1)
- cancer (1)
- cancer treatment (1)
- caudate nucleus (1)
- cells (1)
- chemokine receptor-4 (1)
- cholinergic activity (1)
- combination (1)
- comparability (1)
- diffuse (1)
- dopamine transporter (DAT) (1)
- early response (1)
- ejection fraction (1)
- esophagogastric junction (1)
- evans blue (1)
- experience (1)
- flare phenomenon (1)
- focal (1)
- follicular lymphoma (1)
- giant cell arteritis (1)
- glioblastoma (1)
- glioblastoma multiforme (1)
- glioma (1)
- head and neck cancer (1)
- health care (1)
- hematotoxicity (1)
- human tumor cell lines (1)
- hyperkalemia (1)
- imaging (1)
- imaging proliferation (1)
- imaging techniques (1)
- immunohistochemistry (1)
- immunostaining (1)
- in vivo imaging (1)
- in-vivo (1)
- inflammation (1)
- inhibition (1)
- interobserver (1)
- interreader (1)
- intraindividual comparison (1)
- involvement (1)
- irradiation (1)
- isotopes (1)
- kidney function (1)
- kisspeptin (1)
- late response (1)
- left-ventricular function (1)
- levodopa-induced dyskinesia (1)
- macrophages (1)
- macroscopic recurrence (1)
- magnetic resonance imaging (1)
- malignancies (1)
- mammalian target of rapamycin (1)
- management (1)
- matched pair (1)
- medullary thyroid carcinoma (1)
- metabolic tumor volume (MTV) (1)
- metabolic tumour volume (MTV) (1)
- methionine (1)
- methylphenidate (1)
- microenvironment (1)
- microglial cells (1)
- mouse (1)
- nephrotoxicity (1)
- neuroendocrine neoplasia (1)
- neuroinflammation (1)
- non-Hodgkin's lymphoma (1)
- non-hodgkins-lymphoma (1)
- ollimator (1)
- overall survival (1)
- pancreas (1)
- papillary thyroid carcinoma (PTC) (1)
- pattern (1)
- peptide receptor (1)
- phosphatidylinositol-3-kinase (1)
- photons (1)
- pleural mesothelioma (1)
- polymyalgia rheumatica (1)
- positron emission tomography/computed tomography (1)
- post-reconstruction filtering (1)
- prediction (1)
- progression (1)
- quality (1)
- quantification (1)
- radiogenomics (1)
- radioiodine (1)
- recurrence (1)
- relapse (1)
- renal scintigraphy (1)
- repair (1)
- reporting and data systems (1)
- responsivity (1)
- sarcoidosis (1)
- scanner (1)
- selpercatinib (1)
- signal to noise ratio (1)
- signaling pathway (1)
- simultaneous integrated boost (1)
- single photon emission computed tomography (SPECT) (1)
- skeletal (1)
- small animal SPECT (1)
- small-animal imaging (1)
- smoldering myeloma (1)
- software (1)
- solid tumors (1)
- somatostatin (1)
- somatostatin receptor (SSTR) (1)
- somatostatin receptors (1)
- staging (1)
- standardization (1)
- standardized reporting (1)
- standardized reporting system (1)
- stem-cell transplantation (1)
- striatum (1)
- super ultraviolet (1)
- survival (1)
- target (1)
- taxane (1)
- thyroid carcinoma (TC) (1)
- thyroid carcinomas (1)
- total lesion PSMA (1)
- total lesion glycolysis (TLG) (1)
- total lesion methionine uptake (TLMU) (1)
- treatment response (1)
- tumor (1)
- tyrosine kinase inhibitor (1)
- vasculature (1)
- vasculitis (1)
- vestibular schwannoma (1)
- weight drop (1)
- α-Particle (1)
- γ-H2AX (1)
Institute
- Klinik und Poliklinik für Nuklearmedizin (72) (remove)
Sonstige beteiligte Institutionen
We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.
Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7% radiochemical yield and at a >99% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6–4.4% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.