Background
All international guidelines recommend perioperative antibiotic prophylaxis (PAB) should be routinely administered to patients undergoing cardiac surgery. However, the duration of PAB is heterogeneous and controversial.
Methods
Between 01.01.2011 and 31.12.2011, 1096 consecutive cardiac surgery patients were assigned to one of two groups receiving PAB with a second-generation cephalosporin for either 56 h (group I) or 32 h (group II). Patients’ characteristics, intraoperative data, and the in-hospital follow-up were analysed. Primary endpoint was the incidence of surgical site infection (deep and superficial sternal wound-, and vein harvesting site infection; DSWI/SSWI/VHSI). Secondary endpoints were the incidence of respiratory-, and urinary tract infection, as well as the mortality rate.
Results
615/1096 patients (56,1%) were enrolled (group I: n = 283 versus group II: n = 332). There were no significant differences with regard to patient characteristics, comorbidities, and procedure-related variables. No statistically significant differences were demonstrated concerning primary and secondary endpoints. The incidence of DSWI/SSWI/VHSI were 4/283 (1,4%), 5/283 (1,7%), and 1/283 (0,3%) in group I versus 6/332 (1,8%), 9/332 (2,7%), and 3/332 (0,9%) in group II (p = 0,76/0,59/0,63). In univariate analyses female gender, age, peripheral arterial obstructive disease, operating-time, ICU-duration, transfusion, and respiratory insufficiency were determinants for nosocomial infections (all ≤ 0,05). Subgroup analyses of these high-risk patients did not show any differences between the two regimes (all ≥ 0,05).
Conclusions
Reducing the duration of PAB from 56 h to 32 h in adult cardiac surgery patients was not associated with an increase of nosocomial infection rate, but contributes to reduce antibiotic resistance and health care costs.
Background:
There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT.
Methods:
Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted.
Results:
Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23–27 mm vs. 23 mm; IQR 21–25; p = 0.009).
Conclusions:
Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.