Refine
Has Fulltext
- yes (39)
Is part of the Bibliography
- yes (39)
Year of publication
Document Type
- Journal article (39) (remove)
Language
- English (39)
Keywords
- PET (13)
- Positronen-Emissions-Tomografie (10)
- theranostics (8)
- positron emission tomography (7)
- PRRT (6)
- neuroendocrine tumor (6)
- CXCR4 (5)
- NET (3)
- PET/CT (3)
- SPECT (3)
- SSTR (3)
- peptide receptor radionuclide therapy (3)
- sympathetic nervous system (3)
- 18F-LMI1195 (2)
- DOTATOC (2)
- MAG3 (2)
- PSMA (2)
- Prostate Cancer (2)
- RADS (2)
- chemokine receptor (2)
- diabetes (2)
- heart failure (2)
- kidney (2)
- molecular medicine (2)
- myocardial sympathetic innervation imaging (2)
- norepinephrine transporter (2)
- personalized medicine (2)
- precision medicine (2)
- prostate cancer (2)
- radioligand therapy (2)
- somatostatin receptor (2)
- 11C-HED (1)
- 11C-Hydroxyephedrine (1)
- 11C-hydroxyephedrine (1)
- 123I-Ioflupane (1)
- 123I-mIBG (1)
- 123I-metaiodobenzylguanidine (1)
- 177Lu (1)
- 18F-DCFPL (1)
- 18F-DCFPyL (1)
- 18F-FDG (1)
- 18F-FDS (1)
- 18F-flurpiridaz (1)
- 18FFBnTP (1)
- 2-deoxy-2-(18F)fluoro-D-glucose (1)
- 2-deoxy-2-18F-fluoro-D-sorbitol (1)
- <sup>18</sup>F-FDG (1)
- <sup>68</sup>Ga-Pentixafor (1)
- Antidepressants (1)
- Arginine (1)
- C-X-C motif chemokine receptor 4 (1)
- Cardiovascular diseases (1)
- DaTscan (1)
- ECG (1)
- Ganglia (1)
- HFmrEF (1)
- Heart failure (1)
- Hyperkalaemia (1)
- Imaging pitfalls (1)
- Lysine (1)
- MDD (1)
- MPI (1)
- MRI (1)
- Myocardial-perfusion SPECT (1)
- NEC (1)
- PSMA-PET (1)
- Parkinsonism (1)
- Parkinson’s disease (1)
- Pitfall (1)
- Positron Emission Tomography (1)
- Positron-Emission Tomography (1)
- Positronenemissionstomografie (1)
- Prostata (1)
- Radiofluorine (1)
- Radiotracer (1)
- SPECT Scanner (1)
- SPECT/CT (1)
- SSTR-RADS (1)
- SUV (1)
- Single-Photon-Emissions-Computertomographie (1)
- Sodium-Glucose Cotransporters (SGLTs) (1)
- Stammzelle (1)
- T-shaped π-π stacking (1)
- T-shaped π–π stacking (1)
- TKI (1)
- Tracer (1)
- Virchow Node (1)
- ZDF rats (1)
- [177Lu]-DOTATATE/-DOTATOC (1)
- [177Lu]/[90Y]PentixaTher (1)
- [68Ga] (1)
- [68Ga]PentixaFor (1)
- [68Ga]Pentixafor (1)
- [\(^{68}\)Ga]Ga-FAPI (1)
- [\(^{68}\)Ga]Pentixafor (1)
- \(^{18}\)F (1)
- \(^{18}\)F-FDG (1)
- \(^{18}\)F-fluorodeoxyglucose (1)
- \(^{68}\)Ga (1)
- ageing (1)
- amino acids (1)
- angiogenesis (1)
- antidepressant (1)
- biomarkers (1)
- cardiac innervation imaging (1)
- cardiac neurohormonal system (1)
- cardiac sympathetic nerve system (1)
- cardiac sympathetic nervous system (1)
- cardiomyocytes (1)
- coronary artery disease (1)
- depression (1)
- diabetic cardiomyopathy (1)
- ejection fraction (1)
- endocrinology (1)
- endoradiotherapy (1)
- fatty acid (1)
- fibroblast activation protein (1)
- glomerular filtration rate (1)
- heart failure with mid-range ejection fraction (1)
- hiPSC-CM (1)
- hyperkalemia (1)
- immune infiltration (1)
- induced pluripotent stem cells (1)
- kidney function (1)
- left-ventricular function (1)
- mRNA (1)
- machine learning (1)
- major depressive disorder (1)
- medicine (1)
- medium-sized animals (1)
- medullary thyroid carcinoma (1)
- miRNA (1)
- molecular imaging (1)
- multiple myeloma (1)
- myocardial perfusion imaging (1)
- nephrology (1)
- nonhuman primates (1)
- nuclear cardiology (1)
- pancreas (1)
- performance (1)
- personalized treatment (1)
- phaeochromocytoma (1)
- prostate-specific membrane antigen (1)
- prostate-specific membrane antigen (PSMA) (1)
- radiotracer (1)
- radiotracer kinetics (1)
- rats (1)
- renal (1)
- renal function (1)
- renal imaging (1)
- renal scintigraphy (1)
- reporting and data system (1)
- reporting and data systems (1)
- sarcoidosis (1)
- single photon emission computed tomography: sympathetic nerve (1)
- solid tumors (1)
- somatostatin receptor (SSTR) (1)
- split renal function (1)
- standardization (1)
- stem cell therapy (1)
- stem cells (1)
- stem-cell research (1)
- storage vesicle turnover (1)
- structure–activity relationships (1)
- tracer (1)
- transcriptome (1)
- tumor heterogeneity (1)
- tumor microenvironment (1)
- tyrosine kinase inhibitor (1)
- urology (1)
- vandetanib (1)
Institute
- Klinik und Poliklinik für Nuklearmedizin (39)
- Medizinische Klinik und Poliklinik II (7)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (6)
- Medizinische Klinik und Poliklinik I (6)
- Institut für Pharmazie und Lebensmittelchemie (3)
- Pathologisches Institut (3)
- Comprehensive Cancer Center Mainfranken (2)
- Institut für Klinische Biochemie und Pathobiochemie (2)
- Center for Computational and Theoretical Biology (1)
- Institut für Anatomie und Zellbiologie (1)
Sonstige beteiligte Institutionen
- Johns Hopkins School of Medicine (7)
- Department of Biomedical Imaging, National Cerebral and Cardiovascular Research Center, Suita, Japan (1)
- Department of Nuclear Medicine, Kanazawa University (1)
- Division of Medical Technology and Science, Department of Medical Physics and Engineering, Course of Health Science, Osaka University Graduate School of Medicine, Suita Japan (1)
- Institut for Molecular Biology and CMBI, Department of Genomics, Stem Cell Biology and Regenerative Medicine, Leopold-Franzens-University Innsbruck, Innsbruck, Austria (1)
- Johns Hopkins School of Medicine, Baltimore, MD, USA (1)
- Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Science, Baltimore, MD, USA (1)
- Johns Hopkins University School of Medicine (1)
- Johns Hopkins University, Baltimore, MD, U.S. (1)
- Johns Hopkis School of Medicine (1)
EU-Project number / Contract (GA) number
- 701983 (16)
In diabetic cardiomyopathy, left ventricular (LV) diastolic dysfunction is one of the earliest signs of cardiac involvement prior to the definitive development of heart failure (HF). We aimed to explore the LV diastolic function using electrocardiography (ECG)-gated \(^{18}\)F-fluorodeoxyglucose positron emission tomography (\(^{18}\)F-FDG PET) imaging beyond the assessment of cardiac glucose utilization in a diabetic rat model. ECG-gated \(^{18}\)F-FDG PET imaging was performed in a rat model of type 2 diabetes (ZDF fa/fa) and ZL control rats at age of 13 weeks (n=6, respectively). Under hyperinsulinemic-euglycemic clamp to enhance cardiac activity, \(^{18}\)F-FDG was administered and subsequently, list-mode imaging using a dedicated small animal PET system with ECG signal recording was performed. List-mode data were sorted and reconstructed into tomographic images of 16 frames per cardiac cycle. Left ventricular functional parameters (systolic: LV ejection fraction (EF), heart rate (HR) vs. diastolic: peak filling rate (PFR)) were obtained using an automatic ventricular edge detection software. No significant difference in systolic function could be obtained (ZL controls vs. ZDF rats: LVEF, 62.5±4.2 vs. 59.4±4.5%; HR: 331±35 vs. 309±24 bpm; n.s., respectively). On the contrary, ECG-gated PET imaging showed a mild but significant decrease of PFR in the diabetic rats (ZL controls vs. ZDF rats: 12.1±0.8 vs. 10.2±1 Enddiastolic Volume/sec, P<0.01). Investigating a diabetic rat model, ECG-gated \(^{18}\)F-FDG PET imaging detected LV diastolic dysfunction while systolic function was still preserved. This might open avenues for an early detection of HF onset in high-risk type 2 diabetes before cardiac symptoms become apparent.
Prostate-specific membrane antigen (PSMA)-targeted PET imaging for prostate cancer with \(^{68}\)Ga-labeled compounds has rapidly become adopted as part of routine clinical care in many parts of the world. However, recent years have witnessed the start of a shift from \(^{68}\)Ga- to \(^{18}\)F-labeled PSMA-targeted compounds. The latter imaging agents have several key advantages, which may lay the groundwork for an even more widespread adoption into the clinic. First, facilitated delivery from distant suppliers expands the availability of PET radiopharmaceuticals in smaller hospitals operating a PET center but lacking the patient volume to justify an onsite \(^{68}\)Ge/\(^{68}\)Ga generator. Thus, such an approach meets the increasing demand for PSMA-targeted PET imaging in areas with lower population density and may even lead to cost-savings compared to in-house production. Moreover, \(^{18}\)F-labeled radiotracers have a higher positron yield and lower positron energy, which in turn decreases image noise, improves contrast resolution, and maximizes the likelihood of detecting subtle lesions. In addition, the longer half-life of 110 min allows for improved delayed imaging protocols and flexibility in study design, which may further increase diagnostic accuracy. Moreover, such compounds can be distributed to sites which are not allowed to produce radiotracers on-site due to regulatory issues or to centers without access to a cyclotron. In light of these advantageous characteristics, \(^{18}\)F-labeled PSMA-targeted PET radiotracers may play an important role in both optimizing this transformative imaging modality and making it widely available. We have aimed to provide a concise overview of emerging \(^{18}\)F-labeled PSMA-targeted radiotracers undergoing active clinical development. Given the wide array of available radiotracers, comparative studies are needed to firmly establish the role of the available \(^{18}\)F-labeled compounds in the field of molecular PCa imaging, preferably in different clinical scenarios.
The heart failure (HF) epidemic continues to rise with coronary artery disease (CAD) as one of its main causes. Novel concepts for risk stratification to guide the referring cardiologist towards revascularization procedures are of significant value. Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) agents has demonstrated high accuracy for the detection of clinically relevant stenoses. With positron emission tomography (PET) becoming more widely available, mainly due to its diagnostic performance in oncology, perfusion imaging with that modality is more practical than in the past and overcomes existing limitations of SPECT MPI. Advantages of PET include more reliable quantification of absolute myocardial blood flow, the routine use of computed tomography for attenuation correction, a higher spatiotemporal resolution and a higher count sensitivity. Current PET radiotracers such as rubidium-82 (half-life, 76 sec), oxygen-15 water (2 min) or nitrogen-13 ammonia (10 min) are labeled with radionuclides with very short half-lives, necessitating that stress imaging is performed under pharmacological vasodilator stress instead of exercise testing. However, with the introduction of novel 18F-labeled MPI PET radiotracers (half-life, 110 min), the intrinsic advantages of PET can be combined with exercise testing. Additional advantages of those radiotracers include, but are not limited to: potentially improved cost-effectiveness due to the use of pre-existing delivery systems and superior imaging qualities, mainly due to the shortest positron range among available PET MPI probes. In the present review, widely used PET MPI radiotracers will be reviewed and potential novel 18F-labeled perfusion radiotracers will be discussed.
We aimed to explore the impact of ageing on 11C-Hydroxyephedrine (11C-HED) uptake in the healthy rat heart in a longitudinal setting. To investigate a potential cold mass effect, the influence of specific activity on cardiac 11C-HED uptake was evaluated: 11C-HED was synthesized by N-methylation of (−)-metaraminol as the free base (radiochemical purity >95%) and a wide range of specific activities (0.2–141.9 GBq/μmol) were prepared. \(^{11}\)C-HED (48.7±9.7MBq, ranged 0.2–60.4μg/kg cold mass) was injected in healthy Wistar Rats. Dynamic 23-frame PET images were obtained over 30 min. Time activity curves were generated for the blood input function and myocardial tissue. Cardiac 11C-HED retention index (%/min) was calculated as myocardial tissue activity at 20-30 min divided by the integral of the blood activity curves. Additionally, the impact of ageing on myocardial 11CHED uptake was investigated longitudinally by PET studies at different ages of healthy Wistar Rats. A dose-dependent reduction of cardiac 11C-HED uptake was observed: The estimated retention index as a marker of norepinephrine function decreased at a lower specific activity (higher amount of cold mass). This observed high affinity of 11C-HED to the neural norepinephrine transporter triggered a subsequent study: In a longitudinal setting, the 11C-HED retention index decreased with increasing age. An age-related decline of cardiac sympathetic innervation could be demonstrated. The herein observed cold mass effect might increase in succeeding scans and therefore, 11C-HED microPET studies should be planned with extreme caution if one single radiosynthesis is scheduled for multiple animals.
Purpose: We aim to provide an overview of the conventional single photon emission computed tomography (SPECT) and emerging positron emission tomography (PET) catecholamine analogue tracers for assessing myocardial nerve integrity, in particular focusing on \(^{18}\)F-labeled tracers.
Results: Increasingly, the cardiac sympathetic nervous system (SNS) is being studied by non-invasive molecular imaging approaches. Forming the backbone of myocardial SNS imaging, the norepinephrine (NE) transporter at the sympathetic nerve terminal plays a crucial role for visualizing denervated myocardium: in particular, the single-photon-emitting NE analogue \(^{123}\)I-meta-Iodobenzylguanidine (\(^{123}\)I-mIBG) has demonstrated favorable results in the identification of patients at a high risk for cardiac death. However, cardiac neuronal PET agents offer several advantages inlcuding improved spatio-temporal resolution and intrinsic quantifiability. Compared to their \(^{11}\)C-labeled counterparts with a short half-life (20.4 min), novel \(^{18}\)F-labeled PET imaging agents to assess myocardial nerve integrity have the potential to revolutionize the field of SNS molecular imaging: The longer half-life of \(^{18}\)F (109.8 min) allows for more flexibility in the study design and delivery from central cyclotron facilities to smaller hospitals may lead to further cost reduction. A great deal of progress has been made by the first in-human studies of such \(^{18}\)F-labeled SNS imaging agents. Moreover, dedicated animal platforms open avenues for further insights into the handling of radiolabeled catecholamine analogues at the sympathetic nerve terminal. Conclusions: \(^{18}\)F-labeled imaging agents demonstrate key properties for mapping cardiac sympathetic nerve integrity and might outperform current SPECT-based or \(^{11}\)C-labeled tracers in the long run.
Purpose: The metabolically most active lesion in 2-deoxy-2-(\(^{18}\)F)fluoro-D-glucose (\(^{18}\)F-FDG) PET/CT can predict progression-free survival (PFS) in patients with medullary thyroid carcinoma (MTC) starting treatment with the tyrosine kinase inhibitor (TKI) vandetanib. However, this metric failed in overall survival (OS) prediction. In the present proof of concept study, we aimed to explore the prognostic value of intratumoral textural features (TF) as well as volumetric parameters (total lesion glycolysis, TLG) derived by pre-therapeutic \(^{18}\)F-FDG PET.
Methods: Eighteen patients with progressive MTC underwent baseline \(^{18}\)F-FDG PET/CT prior to and 3 months after vandetanib initiation. By manual segmentation of the tumor burden at baseline and follow-up PET, intratumoral TF and TLG were computed. The ability of TLG, imaging-based TF, and clinical parameters (including age, tumor marker doubling times, prior therapies and RET (rearranged during transfection) mutational status) for prediction of both PFS and OS were evaluated.
Results: The TF Complexity and the volumetric parameter TLG obtained at baseline prior to TKI initiation successfully differentiated between low- and high-risk patients. Complexity allocated 10/18 patients to the high-risk group with an OS of 3.3y (vs. low-risk group, OS=5.3y, 8/18, AUC=0.78, P=0.03). Baseline TLG designated 11/18 patients to the high-risk group (OS=3.5y vs. low-risk group, OS=5y, 7/18, AUC=0.83, P=0.005). The Hazard Ratio for cancer-related death was 6.1 for Complexity (TLG, 9.5). Among investigated clinical parameters, the age at initiation of TKI treatment reached significance for PFS prediction (P=0.02, OS, n.s.).
Conclusions: The TF Complexity and the volumetric parameter TLG are both independent parameters for OS prediction.
Both prostate-specific membrane antigen (PSMA)- and somatostatin receptor (SSTR)-targeted positron emission tomography (PET) imaging agents for staging and restaging of prostate carcinoma or neuroendocrine tumors, respectively, are seeing rapidly expanding use. In addition to diagnostic applications, both classes of radiotracers can be used to triage patients for theranostic endoradiotherapy. While interpreting PSMA- or SSTR-targeted PET/computed tomography (CT) scans, the reader has to be aware of certain pitfalls. Adding to the complexity of the interpretation of those imaging agents, both normal biodistribution, and also false-positive and -negative findings differ between PSMA- and SSTR-targeted PET radiotracers. Herein summarized under the umbrella term molecular imaging reporting and data systems (MI-RADS), two novel RADS classifications for PSMA- and SSTR-targeted PET imaging are described (PSMA- and SSTR-RADS). Both framework systems may contribute to increase the level of a reader’s confidence and to navigate the imaging interpreter through indeterminate lesions, so that appropriate workup for equivocal findings can be pursued. Notably, PSMA- and SSTR-RADS are structured in a reciprocal fashion, i.e. if the reader is familiar with one system, the other system can readily be applied as well. In the present review we will discuss the most common pitfalls on PSMA- and SSTR-targeted PET/CT, briefly introduce PSMA- and SSTR-RADS, and define a future role of the umbrella framework MI-RADS compared to other harmonization systems.
Peptide Receptor Radionuclide Therapy (PRRT) for the treatment of neuroendocrine tumors may lead to kidney deterioration. This study aimed to evaluate the suitability of \(^{99m}\)Tc-mercaptoacetyltriglycine (\(^{99m}\)Tc-MAG3) clearance for the early detection of PRRT-induced changes on tubular extraction (TE). TE rate (TER) was measured prior to 128 PRRT cycles (7.6±0.4 GBq \(^{177}\)Lu-octreotate/octreotide each) in 32 patients. TER reduction during PRRT was corrected for age-related decrease and analyzed for the potential to predict loss of glomerular filtration (GF). The GF rate (GFR) as measure for renal function was derived from serum creatinine. The mean TER was 234 ± 53 ml/min/1.73 m² before PRRT (baseline) and 221 ± 45 ml/min/1.73 m² after a median follow-up of 370 days. The age-corrected decrease (mean: -3%, range: -27% to +19%) did not reach significance (p=0.09) but significantly correlated with the baseline TER (Spearman p=-0.62, p<0.001). Patients with low baseline TER showed an improved TER after PRRT, high decreases were only observed in individuals with high baseline TER. Pre-therapeutic TER data were inferior to plasma creatinine-derived GFR estimates in predicting late nephropathy. TER assessed by \(^{99m}\)Tc-MAG3clearance prior to and during PRRT is not suitable as early predictor of renal injury and an increased risk for late nephropathy.